Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File 4402 San Juan Avenue
y � �,Z Y o CITY OF ANACORTES WASHINGTON v 9coa'�rco BUILDING DEPARTMENT CERTIFICATE OF OCCUPANCY This is to certify that the(Description of Building or Structure): New Single Family Located At: 4402 San Juan STREET&NUMBER Owner: Sean Kelly Constructed By: Lytle Construction OWNER OR CONTRACTOR Bldg.Permit#COM93-0010 Date Of Issue: 11-23--93 Occ.Group: R3 Use Zone: R2 Has Been Inspected And Occupancy Is Hereby Authorized, This 8th Day Of September 19 95 \ ' U� AUTHORIZING OFFICIAL SEE REVERSE SIDE FOR SPECIAL REQUIREMENTS. COMBINATION PERMIT CITY OF ANACORTES PERMIT NO. : COM93-0010 P.O. BOX 547 APPLIED: 11/19/93 ANACORTES, WA 98221 ISSUED: 11/23/93 (206) 293-1901 EXPIRES: 11/23/94 SITE ADDRESS: 4402 SAN JUAN ASSESSOR' S PARCEL NO. : 4410-000-076-0005 PROJECT DESCRIPTION: New single family residence. — OWNER — CONTRACTOR — LENDER SEAN KELLY LYTLE CONSTRUCTION 501-B 30TH STREET P.O. BOX 427 ANACORTES WA 98221 ANACORTES WA 98221 299-0910 293-0481 LYTLE"106P0 — FEES TYPE OF WORK •NEW AREA (sf) VALU...$: 124000 Code Amount---- By- Date---- Receipt TYPE OF USE -SF LOT 0 REQUIRED SETBACKS---- ESPL $ -100.00 EF 11/23/93 7758 CENSUS CATEGORY •101 1ST FLR • 1568 FRONT • 20 ft PLCK $ 320.45 EF 11/23/93 1758 ZONING 2ND FLR • 1522 SIDE(1)..: 5 ft PRMT $ 493.00 EF 11/23/93 1758 :RL BASEMENT 0 SIDE(2)..: 10 ft PMEC $ 53.50 EF 11/23/93 1758 OCCUPANCY GROUP GAR/CARPORT...: 628 REAR • 20 ft PPLM $ 104.00 EF 11/23/93 1758 :R3 •? •? •? OTHER • 320 REQUIRED PARKING-- STBC $ 4.50 EF 11/23/93 1758 TYPE OF CONSTRUCTION TOTAL • 0 IMPT $ 400.00 EF 11/23/93 1758 :5N •? •? :? : NUMBER OF UNITS • 1 ACCESSIBLE.: 0 MISC $ 20.00 EF 11/23/93 1758 OCCUPANT LOAD STORIES • 2 COMPACT • 0 INSP $ 50.00 EF 11/23/93 1758 0: 0: 0: 0: BUILDING HEIGHT.: 0 ft IMPRV SURF.: 0 sf SEWR $ 2972.00 EF 11/23/93 1758 FUEL TYPES BOILERS/COMPRESSORS- DOMES. INCIN •0 :/GAS/ / /: 0-3 HP • 0 COMML. INCIN •0 FURN < 100K BTU: 0 3-15 HP • 0 RELOC/REPAIR.,.: 0 TOTAL $ 4317.45 FURN >=100K BTU: 0 15-30 HP • 0 CLOTHES DRYERS.: 1 FURN - FLOOR...: 0 30-50 HP • 0 GAS WTR HEATERS: 1 — NOTES UNIT HEATERS...: 0 50+ HP • 0 STOVE, APPLI.,.: 0 VENT FANS • 5 AIR HANDLING UNITS-- FIRE LOG/LITE..: 0 VENT SYSTEMS...: 0 <= 10000 cfm.: 0 WOODSTOVES • 0 VENT W/0 APPLI.: 0 > 10000 cfm.: 0 OTHER UNITS • 0 EVAP COOLERS...: 0 GAS OUTLETS • 1 HOODS • 0 WATER CLOSETS...: 2 WASHING MACHINES: 1 FLOOR DRAINS • 0 BATH TUBS • 2 ELEC WTR HEATERS: 0 WTR PIPING/TREAT: 1 SHOWERS • 0 LAUNDRY TRAYS...: 0 HOSE BIBBS • 1 DISHWASHERS • 1 URINALS • 0 GREASE TRAPS • 0 LAVATORIES • 3 WASTE INTERCEPT.: 0 ADD'L FIXTURES..: 0 KIT SINKS W/DISP: 1 DRINKING FOUNT..: 0 I hereby acknowledge that 1 have read this permit and state that the above information is correct, and agree to comply with all ordinances and laws regulating activities covered by this permit. Issued b pli ant or w e s Signature 24 Hour Notice Requi ed For All Inspections com_prmt, Rev: 11/04/93 • WATTBUN 5 . 4 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 09/28/93 FILE: C:\\WATTSUN5\\KELLY.WS HOUSE ID: Kelly Residence Site: 4202 San Juan Place Analyst: Don Ramey Anacortes, WA 98221 Jurisdiction: Anacortes ( 206 )299-0910 Utility: Rampart Mechanical Corp. Homeowner: Sean and Debbie Kelly House Type: Single Family 3515 W. 7th Place Floor Area: 1568 ft2 (206)299-0910 Builder: Lytle Construction Weather Data: Anacortes, WA 2318 Commercial Avenue Climate Zone: 1 (Whidbey Island, WA) (206 )293-1309 _ The PROPOSED design *COMPLIES* with 1991 WA State Energy Code. REFERENCE PROPOSED COMPONENT PERFORMANCE 385 330 Btu/hr-F ENERGY BUDGET 8. 50 5 .92 kWh/ft2-yr REFERENCE DESIGN • Reference Component Value X Area = UA Floor U-0. 041 1568 64.3 Glazing Q15% U-0. 650 235. 2 152 .9 Doors U-0. 400 40.0 16 . 0 AG Wall U-0 . 062 1573 97 . 5 Ceiling, Vault U-0 .034 1608 54 . 7 Infiltration ACH-0 . 350 13574ft3( 86.9 ) F Reference UA 385 PROPOSED DESIGN COMPONENTS Component Description Value X Area = UA Floor R19 vented Joist 16oc U-0 .041. 1568 64 . 3 Glazing @16% **Milgard 2GL SH Clr/Clr w/TB U-0 . 400 196 .0 78 .4 **Andersen Frenchwd Hngd Patio Dr 2GL U-0 .290 58 .0 16 .8 Doors **Peachtree A31C Fire Door U-0 . 140 20 .0 2 . 8 1 **Peachtree A300 Metal Entry Door U-0 . 190 20.0 3 .8 AG Wall R19 STD Lap Wood U-0 . 062 1554 96. 3 Skylights @3%**Milgard Bronzed Aluminum 2GL U-0 . 400 40 .0 16 .0 Items in parentheses not included in COMPONENT PERFORMANCE totals. ** Denotes non-standard values - check calculation of thermal value. Page 1 - WATT'SUN 5 . 4 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 09/28/93 FILE: C:\\WATTSUNS\\KELLY.WS HOUSE ID: Kelly Residence Ceiling R30 batt Vault vented 2x12 24oc U-0.033 1568 51 . 7 Infiltration Standard Air Sealing ACH-0. 350 13574ft3 ( 86.9) Proposed UA 330 Struc Mass Light Frame, Sheetrock walls M- 3 .000 1568 4704 HEATING/COOLING/VENTILATING SYSTEMS PROPOSED Heating System Type: Gas Furnace Make: Trane Model : TUD060R936A/ System Efficiency: 80 % Modified Efficiency: 63 % Design ACH: 0.60 Design Load(at 55F dt) : 27178 Btu/hr Duct Losses(% Dsn Load) : 6115 Btu/hr(22%) Total Load: 33293 Btu/hr System Size: 50000 Btu/hr ( 150%) Average Annual Heat: 46 MBtu Annual Cost: $ 257 Ventilation System: Integrated w/Forced Air Furnace Cooling System: NONE SEER: 0.0 (Ducted) Cooling Load(at -3F dt) : 19933 Btu/hr System Size(%Over) : 2 . 3 tons(@125%) Annual Cool Requirement: *** kWh/yr Solar Access: Unshaded w/solar access PROPOSED DUCT SYSTEM Location Avg Rvalue Surface Area SUPPLY Vented crawlspace R- 8 .0 313 . 6 ft2 RETURN Attic or garage R- 8 .0 62 . 7 ft2 • Page 2 ' WATT'SUN 5 . 4 1991 WA STATE ENERGY CODE COMPLIANCE REPORT 09/28/93 FILE: C:\\WATTSUN5\\KELLY.WS HOUSE ID: Kelly Residence GLAZING ORIENTATION PROPOSED PROPOSED South 63 . 5ft2 North . 63 . 5ft2 Southeast : Northwest : East . 63 . 5 West 63 . 5 Northeast : Southwest : Economic and energy consumption estimates are designed for comparative purposes only. Actual cost for heating will vary depending on weather conditions, occupant lifestyle and other factors . Page 3 INSULATION CERTIFICATE 026727 SEAN KELLY 4402 SAN JUAN 4402 SAN JUAN ANACORTES, WA. ANACORTES, WA. 98221 'CLEARIDGE' Type of Material Manufacturer Thickness Sg Ft Covered R Value Width t Saga Wt/Bag AIR SEAL 44'CORRU6AIED CARDBOARD BAFFLES 0 50 PKENOT APPLICABLE 50.00 HBR BACKER ROD 3/8° NOT APPLICABLE Total Sq Ft Installed: 50.00 ATTIC BLOW INSUL-SAFE III BLOWING WOOL CERTAIN-TEEDCERTAINTEED 12.50 456.00 30 10.00 35.00 Total Sq Ft Installed: 456.00 EXTERIOR WALLS R-8 UNFACED CERTAINTEED CERTAINTEED 2.50 110.00 8 R-19 UNFACED OVENS-CORNING OWENS-CORNING 6.25 1705.00 19 Total Sq Ft Installed: 1815.00 KNEEWALLS R-19 KRAFT OWENS-CORNING OVENS-CORNING 6.25 168.00 19 Total Sq Ft Installed: 168.00 RIM JOISTS R-19 UNFACED OWENS-CORNING OWENS-CORNIN6 6.25 155.00 19 Total Sq Ft Installed: 155.00 SOUND WALLS R-11 UNFACED CERTAINTEED CERTAINTEED 3.50 817.00 11 Total Sq Ft Installed: 817.00 FLAT CEILING-BATTS R-30 UNFACED OVENS-CORNING OVENS-CORNING 9.00 240.00 30 Total Sq Ft Installed: 240.00 SLOPED CEILING R-30 UNFACED OVENS-CORNING OWENS-CORNING 9.00 960.00 30 Total Sq Ft Installed: 960.00 Remarks: Sono-Therm Insulation, Inc. SO NO TI * 26466 Page No. 1 CASE HISTORY FOR CASE NO.: COM93-0010 SEAN KELLY 4402 SAN JUAN 03/30/95 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By COMA010 Application received / / / / 11/19/93 11/19/93 MD COMA500 (F) Issue permit / / / / 11/23/93 OK DM 11/23/93 EF COMA500 (F) Issue permit / / / / 02/06/95 DONE MRD 02/06/95 MD COMB110 INSP - footings 11/30/93 / / 11/29/93 OK DON 11/30/93 MD COMB120 INSP - foundation walls 12/07/93 / / 12/06/93 OK DON 12/07/93 MD COMB150 INSP - framing 02/28/94 / / 02/25/94 CORR DON 02/28/94 MD COMB150 INSP - framing 03/01/94 / / 02/28/94 OK DON 03/01/94 MD COMB210 INSP - insulation 03/03/94 / / 03/03/94 OK DON 03/03/94 MD COMB900 INSP - final 05/31/94 / / 05/27/94 CORR DON 05/31/94 MD COMB900 INSP - final 11/09/94 / / 11/08/94 CORR DON 11/09/94 MD COMC100 INSP - gas piping/pressure 02/23/94 / / 02/22/94 OK DON 02/23/94 MD COMC200 INSP - ducting 02/28/94 / / 02/28/94 OK DON 02/28/94 MD COMD100 INSP - rough plumbing 02/28/94 / / 02/28/94 OK DON 02/28/94 MD BUILDING PERMIT CITY OF ANACORTES PERMIT NO. : BLD95-0034 P.O. BOX 547 APPLIED: 02/06/95 ANACORTES, WA 98221 ISSUED: 02/06/95 (206) 293-1901 EXPIRES: 02/06/96 SITE ADDRESS: 4402 SAN JUAN ASSESSOR'S PARCEL NO. : 4410-000-076-0005 PROJECT DESCRIPTION: Renew building permit number COM93-0010. — OWNER — CONTRACTOR — LENDER SEAN KELLY 501-B 30TH STREET ANACORTES WA 98221 299-0910 TYPE OF WORK *ADD AREA (sf) VALU. . .$: 0 TYPE OF USE •SF LOT • 0 REQUIRED SETBACKS---- CENSUS CATEGORY •999 1ST FLR • 0 FRONT 0 ft I ZONING 2ND FLR • 0 SIDE • 0 ft :R2 BASEMENT • 0 REAR • 0 ft OCCUPANCY GROUP GAR/CARPORT. . . : 0 REQUIRED PARKING-- :R3 :? :? :? OTHER 0 TOTAL • 0 TYPE OF CONSTRUCTION HANDICAPPED: 0 :5N :? :? :? NUMBER OF UNITS • 0 COMPACT • 0 OCCUPANT LOAD STORIES • 0 IMPRV SURF. : 0 sf . 0: 0: 0: 0: BUILDING HEIGHT. : 0 ft — FEES — NOTES Code Amount---- By- Date---- Receipt RISC $ 246.50 MD 02/06/95 3458 TOTAL $ 246.50 I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all ordinances and laws regulating activities covered by this permit. Issued by Applicant or Owner's Signature 24 Hour Notice Required For All Inspections bldjrmt, Rev: 06/11/92 • i DATE: � \S lei-7 PERMIT NO: • CITY OF ANACORTES PLUMBING AND MECHANICAL PERMIT SITE ADDRESS: 140Z- Th ,u /{uA-2 4vc A,hkcnGcrncs. � wA c382.'c! ASSESSOR'S NUMBER: LOT: '7�p BLOCK:/ OF: C��E'/�12-1DG- E OWNERS NAME: SEAM\ IctLi--S' PHONE: 2q', ADDRESS: 41-11-OZ SPd 'SAVT-Nt .J uv .. ..::.:v.-T:::'.]lv..])n.]\�:'<�:'y:.JL ..a, •, >"Yk'. ).» ,nw,q':": .:,.V, ..�' .v .':w�.tsS ,.:� e '.av":ii><:.;, <Z]?.». L::i;.,...Lx.a.fl>'. `3':i?i::i :;rxm.,rc�. a .%,jt>t%y ..].,txic.::.. „n. :.v. :.x2>.:>.3:ex? � MA3•Ot.' ix. c.'a:•->i(,,,,.sr^i W?...te)." ..?;..{x£?iCr' ;..,Y,L>; >)>yL, >s„t .:D' a »: ^•' zr,„oti„, r �". ;;(('' :ati,.,.c k x'x�i:.>: •+ t'� .'.>x:.;.3 ...:«r:;'].rr.;<:, >.)v:ii':. : xx . ii. '.�(','i '.g�C'ai., ..x.�:i:: f s£hy':i>ira , :; Vi ;. m ......... ..... •.c: `,xa".vaiis .:�.ro¢,..., �.,,...iiL.�:::c: ��)i..:..:,.:....Lxi.......o<:.:.::::....:a.,....xtd...%�.:...........dr.:x.....,.. ..C":.: < :`a`h`.fG.(� �:]:ii��>Soif'xn�: CONTRACTOR: ilU47/A/5 /A-. biN r CONTRACTOR: 4N40)7ZT&S Wow ff ne40-0.16/ PHONE: ZCS - 'Zi PHONE: 2oCa- Z93" CONTRACTORS LIC. NO: CONTRACTORS LIC. NO: NO TYPE OF FIXTURE OR ITEM NO TYPE OF EQUIPMENT ca WATER CLOSET 3.5 GPM AIR COND. UNIT BATHTUB REFRIGERATION UNIT HP SHOWER 3.0 GPM BOILER HP _ I DISHWASHER 9.0 GPM ( FORCED AIT SYSTEM BTU/HP LAVATORY 3.0 GPM FLOOR FURNACE BTU ( KITCHEN SINK 3.0 GPM WALL HEATER ' CLOTHES WASHER CLOTHES DRYER BTU URINAL 3.0 GPM VENTILIATION FAN DRINKING FOUNTIAN / RANGE HOOD FLOOR SIP)K OR DRAIN AIR HANDLING UNIT CEM SLOP SINK PRE-MANF. STOVE OR FIREPLACE WATER PIPING GAS FIREPLACE BTU LAUNDRY SINK: ( GAS WATER HEATER BTU OTHER(DESCRIBE) : ( GAS PIPING OTHER(DESCRIBE) : _ I GAS: OIL: ELEC: OTHER: NOTICE THIS APPLICATION IS RECEIVED BY THE BUILDING OFFICIAL UNDER THE PROVISIONS OF THE UNIFORM PLUMBING AND MECHANICAL CODES AND SHALL EXPIRE BY LIMITATION AND BECOME NULL AND VOID IF PERMIT IS NOT OBTAINED WITHIN 180 DAYS OF THIS APPLICATION. BY AFFIXING MY SIGNATURE I HEREBY CERTIFY THAT I AM THE LEGAL OWNER OF THE PROPERTY FOR WHICH THIS APPLICATION IS ISSUED OR AN AUTHORIZED AGENT OF THE OWNER. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT,INCLUDING CALLS FOR INSPECTIONS. SIGNATURE : ,� _ DATE : � C1 /I5/q3 ti1_ FINAL INSPECTION CHECKLIST C© © �o Inspection Date: 9- e r /S Address: L/t{02 SAAJ J c.,A,U Permit No. (3M 73 od/UDate: //-23— 9_3 zone: TAG Owners Name: 5 a_-p&t /16 L c y Owners Address: so/- a 3 v; 4 428-E7 Contractors Name: /vine ( t S72' ******************* **************************************** Occupancy Group: l2 3, /mot / Consruction Type: VA/ Variances: A/47,lc Safety Glass: o`"" Sewer Fee Paid:1//O 3/91 Hand Rails: 0 C----- Sewer Inspected: Guard Rails: DV Oe WSEC Compliance: C"- Traps: .er 0 C__, X- Attic Access: D Wood Stove: ifs Smoke Detectors: :tr. Water Pressure: -1E k T&P Drain: V�\ House Numbers: ?3(--____ _ok- b- Insulation Cert: 0�.. Site Drainage: H. Radon Test Kit: 5- 1"7-Ry Curb Cut: c"��- Garage House Door: PJ 4- Crawl Space Insul-: a`t 451 Bedroom Windows: 0 t Crawl Space Access: ow I<Water Heater Strap: o'. Vapor Barrier: .0 iv w D.W. Air Gap: O t- Water MeterBox: o°" Auto Garage Door: ci Outside Caulking: Ot-- ( Exterior Decks/Landings: D L-----. Exh. Duct/Dryer Vent Dampers: 19 L-- --