Loading...
HomeMy WebLinkAboutPermit File BLD-2021-0657 3810 Sterling Place City of Anacortes Invoice/Permit#: BLD-2021-0657 904 6th Street Applied date: 08/03/2021 P.O.Box 547 Issue date: 08/09/2021 _ 0, Anacortes, WA 98221-0547 Expire date: 02/05/2023 (360) 293-1901 Job Address: 3810 STERLING PL Permit Type: Single Family Alteration/Repair Permit ANACORTES WA 98221-1296 Project: APN: P107110 Remarks: REPLACE REAR DECK WITH A LARGER DECK OVER AN ENCLOSED SHED. Owner: KELLY&SUSAN LAFAVE Contractor: OWNER Address: 3810 STERLING PL Address: ANACORTES WA 98221-1296 Phone: (360)466-8627 Phone: License#: General Information: Fees: Deck Square Footage 441 Building Permit Fee 111.25 Flood plain development N Plan Review Fee 72.31 Building Valuation 4500 State Building Code Fee Resi 6.50 Total Calculated: 190.06 Deposits/Receipts: 0.00 Total Due: 190.06 The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and examined this application and know the same to be true and correct. „%ll V SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY 1T y o PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Alike Mailing Address: P.O. Box 547, Anacortes, WA 98221 4 Office Location:904 6th Street, Anacortes WA 98821 t 4111120 Phone: (360)293-1901 Residential Building Permit Application Submittal Packet New Single Family Residences (SFR) Duplexes Additions and Remodels (SFR & Duplex) Accessory Dwelling Units Manufactured Homes Residential decks and retaining walls FORM BP-1: RESIDENTIAL BUILDING PERMIT APPLICATION 1. PROPERTY INFORMATION Project Address(Street,Suite#): Assessor Parcel Number: Subdivision/Lot#: Zoning Designation: Lot area (size): sq.ft. 2. TYPE OF PROJECT ❑ New SFR ❑ New Accessory Dwelling Unit: ❑ Deck/porch (new/repair) ❑ New Duplex ❑ Attached to Primary Unit ❑ Interior remodel n Detached from Primary Unit ❑ New Addition to SFR ❑ Garage, carport or accessory building ❑ Retaining wall or duplex (new/repair) ❑ Other: Project Summary: Project Valuation: $ 3. PROPERTY OWNER INFORMATION Name: Phone: Address(Street,City,State,Zip): Email Address: 4. CONTRACTOR INFORMATION Name:* Phone: Contractor's Business Licenses State License#: City License#: *All Contractors&Subcontractors must have a valid City of Anacortes business license prior to doing work in the Expiration Date: Expiration Date: City. Address(Street,City,State,Zip): Email Address: Page 1 of 19 Res.Building Permit Application Submittal Checklist Updated March 12,2021 G� y PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 ‘7 lerOffice Location:904 6t"Street, Anacortes WA 98821 `4' Phone: (360)293-1901 5. CONTACT PERSON Select one person the city will contact for anything related to this project: ❑ Applicant ❑ Property Owner ElContractor r1 Other(lict helnwl Name: Phone: Address(Street,City,State,Zip): Email Address: 6. LENDER INFORMATION RCW 19.27.095 requires the City to obtain information with regard to lenders. If there are no lenders involved with your project, write"no lenders"on the Name Line below. Name: Phone: Address(Street,City,State,Zip): Email Address: 7. ACKNOWLEDGEMENTS & SIGNATURE Read and initial each of the following statements prior to signing this application: I understand that when a building permit application is taken in over the counter it does not mean the application has been deemed technically complete and sufficient for staff review. I understand that if I submit incomplete, inaccurate, and/or erroneous information it will take the City longer to process my permits. I understand and acknowledge that I could be responsible for providing as-built drawings (on paper or electronically) as part of the project's certificate of occupancy process. I understand and acknowledge that Special Inspections could be required as part of my project, and if needed I will be required to pay for the cost of these inspections. I understand and acknowledge that financial securities could be required as part of the work I am completing and I agree to provide the items needed for the City to calculate these securities and to provide the securities themselves. I understand that if permits are reviewed concurrently such as design review, site plan,traffic concurrency, etc., any required revisions to one permit may affect the entire plan set and could add costs and time to the project. Res.Building Permit Application Submittal Checklist Updated March 12,2021 Page 2 of 19 r YQ� PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location:904 6t"Street, Anacortes WA 98821 'M rk`4 Phone: (360)293-1901 I hereby declare that I am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. I also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein, and the information submitted with this application form is in all respects,true, correct, and complete to the best of knowledge and belief. Signature Date Printed Name Res.Building Permit Application Submittal Checklist Updated March 12,2021 Page 3 of 19 Gl PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 w„ Phone: (360)293-1901 FORM BP-2: STRUCTURE AND SITE INFORMATION 1. PROPERTY WHERE WORK IS OCCURRING ADDRESS: PARCEL NIJMRFR(S1 2. DETAILED PROPOSED STRUCTURE INFORMATION Complete the following information as it relates to your project. Mark items that are not applicable with „N/A„ Structure height: AREA SQUARE FOOTAGE OCCUPANCY GROUP CONSTRUCTION TYPE OCCUPANT LOAD 1st Floor: 2nd Floor: 3rd Floor: Basement: Garage: Total deck: Total porch: Other: Other: Other: 3. QUESTIONS ABOUT THE PROPOSED STRUCTURE Is a fire sprinkler system being installed? ❑ YES ❑ NO Is a monitored fire alarm being installed? ❑ YES ❑ NO Are retaining wall(s) being built? ❑ YES ❑ NO Are structural plans required? ❑ YES ❑ NO 4. PROJECT SITE INFORMATION A. Is work within the City's right-of-way proposed? If yes,you will be required I ❑ YES ❑ NO to submit a right-of-way permit application. If you have already submitted a ROW permit, list the permit number here: _ B. Is the property located in a flood zone? ❑ YES ❑ NO _ If yes, list the flood zone designation: • C. Are there slopes in excess of 15% on or abutting the site? If yes, a ❑ YES ❑ NO geotechnical report will likely need to be submitted. Res. Building Permit Application Submittal Checklist Updated March 12,2021 Page 8 of 19 G1� y PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location:904 6t"Street, Anacortes WA 98821 \+ `Q Phone: (360)293-1901 .Ncor D. Are there critical areas or buffers on or abutting(within 300-feet of)the ❑ YES ❑ NO project site? If yes, a critical areas report will likely need to be submitted. E. Is the lot less than 5,000 sq.ft. in area? ❑ YES ❑ NO If yes,your site and building will need to comply with the standards in AMC 19.43.010.C. F. Is your project involving an accessory dwelling unit? ❑ YES ❑ NO If yes, your site and building will need to comply with the standards in AMC 19.47. G. Will more than 2-acres be cleared and/or more than 5,000 board feet ❑ YES ❑ NO (about 1 log truck load) of timber be harvested? If so you may need to obtain a forest practices permit from DNR. H. Is this project subject to the SEPA process? If yes,you will be required to ❑ YES ❑ NO submit a SEPA checklist. If you have already completed the SEPA process, list the permit number here: 5. REQUIRED SIGNATURE I hereby declare that I am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. I also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein, and the information submitted with this application form is in all respects, true, correct, and complete to the best of knowledge and belief. Signature Date Printed Name Res.Building Permit Application Submittal Checklist Updated March 12,2021 Page 9 of 19 G111 Y 0 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location:904 6t"Street, Anacortes WA 98821 ‘` `, Phone: (360)293-1901 FORM BP-4: ARCHITECTURAL PLAN REQUIREMENTS 1. PROPERTY WHERE WORK IS OCCURRING ADDRESS: PARCEL NUMBER(S) 2. GENERAL INFORMATION This form is intended to assist applicants in creating complete, code compliant architectural plans. Please check the plans you wish to submit to make sure they contain each of the listed items. To the right of the Requirements column is space for you to list the sheet number of the plan set where the listed information is shown. • Minimum Plan Size: 11"x 17" and drawn in an architectural scale. • Architectural plans for structures 4,000 square feet or larger are required to be prepared and stamped by an architect licensed in the State of Washington. • Structural plans must be stamped by a structural engineer licensed in the state of Washington. 3. REQUIREMENTS FOR ALL ARCHITECTURAL PLANS COMPLETE REQUIREMENTS PAGE#ON ? YOUR PLANS Cover(or 1st page) must include: • Site address • Parcel number • Lot number(if applicable) • Lot size • Lot coverage • % impervious surface coverage Floor plans with existing (if applicable) and proposed building layout with square footages and with the use of each room/area labeled. Window and door sizes labeled and window ventilation area. Commercial, Multi-Family, and Mixed-Use Structures must also include door and window schedules. Plumbing, duct, and electrical layout. Penetration protection must be shown. Opening headers, size, and material. Cross section details, showing typical foundation,floor,wall, ceiling and roof construction and insulation. Structural members labeled as to size and spacing as well as bracing, blocking, bridging, special connectors, and anchor bolts. Details documenting energy code compliance. Exterior building elevations demonstrating compliance with applicable structure type design standards (small lot, duplex, or ADU) and maximum building height Res.Building Permit Application Submittal Checklist Updated March 12,2021 Page 11 of 19 y PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location:904 6t"Street, Anacortes WA 98821 � w� Phone: (360)293-1901 Building height(see AMC 19.42.120 for measurement methods,exceptions and modifications). • Label the building height at the highest point of the structure from the average of the natural topography at the foundation at the front of the building. • Label the average elevation of the natural topography at the front of the building. • Label the elevation at the center of all exterior walls of the proposed building. • For ADUs only, include elevations demonstrating compliance with the height/setback plane(see AMC 19.47.030(C)(6)). Special details as needed (i.e., stairs,fireplaces, special construction). Insulation and insulation values of walls, slab, floors, and roof/ceiling. Existing and proposed grades with slope of lot shown. Res.Building Permit Application Submittal Checklist Updated March 12,2021 Page 12 of 19 G111 Y o PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT i Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location:904 6t"Street, Anacortes WA 98821 7� O `�� Phone: (360)293-1901 \coR. FORM BP-5: STORMWATER MANAGEMENT MINIMUM REQUIREMENTS DETERMINATION 1. PROPERTY WHERE WORK IS OCCURRING ADDRESS: PARCEL NUMBER(S) 2. GENERAL INFORMATION Most development within the City of Anacortes that involves disruption of soils,or construction of buildings, streets, parking lots,etc. requires a Stormwater review. Stormwater review requirements are based on either the amount of soil to be disturbed (grading,vegetation removal),or the amount of hard surface that is created or replaced on a site(building footprint,concrete,asphalt or gravel parking,sidewalk,etc.) This form is largely targeted for small projects and single family residences. For larger projects and more information please refer to the Anacortes Municipal Code(Chapter 19.76 Stormwater Management)and the latest Washington State Department of Ecology Stormwater Management Manual for Western Washington (Ecology Manual). 3. HARD SURFACE AREA CALCULATION Please calculate your project's hard surface amount;guidance is provided on the next page of this document. Use your project's total hard surface calculation to follow the flow chart(s) in this packet and determine the level of stormwater management required for you project. When determining your permit level or if stormwater thresholds are met or exceeded the entire project must be considered. A project is that portion of a property, properties, or right of way subject to land disturbing activities, new hard surfaces and replaced hard surfaces. The hard surface on your property will determine the storm water utility fees and the stormwater general facility charge. All new or replaced hard surfaces should be accounted for. Below are excerpts from the Anacortes Municipal Code and Ecology Manual that may assist you in preparing this information. "Hard surface area"means an impervious surface, a permeable pavement, or a vegetated roof. "Impervious surface"means a non-vegetated surface area which either prevents or retards the entry of water into the soil mantle as under natural conditions prior to development. A non-vegetated surface area which causes water to run off the surface in greater quantities or at an increased rate of flow from the flow present under natural conditions prior to development. "Replaced impervious surface"means,for structures, the removal and replacement of impervious surfaces down to the foundation. For other impervious surfaces, the removal down to bare soil or base course and replacement. Res.Building Permit Application Submittal Checklist Updated March 12,2021 Page 13 of 19 Gl PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 w� Phone: (360)293-1901 Land disturbance Description Total (SF) Total Area of Land disturbing activity Total area converted from vegetation to lawn or landscaped areas Hard surface area calculation Existing Removed Proposed Proposed Description (SF) (SF) Replaced New (SF) (SF) Non Pollution Generating Hard Surface Area (Sidewalks, paths, patios, etc.) Pollution Generating Hard Surface Area (Driveways, parking areas, etc.) Total Hard Surface Site Size Existing impervious surface coverage (sq.ft. hard surface/site size) Use the information in the above table to navigate the flow chart(s) on the next page and determine the applicable stormwater management minimum requirements for your project. Then complete the applicable Stormwater Minimum Requirements Form on the Public Works - Engineering Department Forms website and provide required submittal items/plans. Check applicable box Minimum Requirements Determination Minimum Requirements #1-9. Minimum Requirements #1-5. Res.Building PerrjApplication Submittal Checklist Updated March 1 ;2021 Minimum Requirement#2. Page 14 of 19 1Og COD�CO ,w� G1T Y fe t�Q ,,��' , , FIELD vSe , �, ,'`, P 1 d7087 \ \ ,'` C ) ` S ��\ SINGLE FAMILY RESIDENCE P10708 3 / j A '� KELLY AND SUSAN LAFAVE ,;t `, P1o`�oso1', ' 3810 STERLING PLACE % ANACORTES, WA 98221 , 6 P107091 % 33 (360) 466-8627 32 ` ' '`, 7 P\07092 °, P107120 KDLaFave@gmail.com \ -::"!- ", �' �' �' P107119 31 a,, P10'R093 I:,�I� \�GC 30 P107118 P107094 ,, ����� EXISTING 29 P107117 FENCE � ` �n��uV� '��Q�� PROPOSED '` LOT PPB'" LS nn11 DECK ,'� P107116 ° �°�� EXISTING ` S . HOUSE 22 / \ LOT "A" P107115 P107109 \ . \ _ 24 z3 9 P1071142 25 P107110 21 �� P107095 P107113 3810 P107111 P107112 ERL1 STERLING 27 PLACE P107108 �� 10 \ c-, -r m- I h of iL �I _ i,� oi, CITY OF ANACORTES P107096 ��S _ E IN IL III 111111 G r L ^ Ly IL - 20 7"' - PLANNING AND BUILDING DEPT: L= P107107 11 APPROVED PLANS ® 12 13 14 15 16 17 18 REVIEWED FOR CODE COMPLIANCE P107097 PERMIT#: BLD-2021-0657 P107098 P107099 P107100 P107102 P107103 P107104 P107105 ADDRESS: 3810 TE LI P_L , \ — APPROVED BY: Z Z Z Z 19 SUBJECT TO FIELD INSPECTION. APPROVED PL S SHALL NOT BE ALTERED WITHOUT AUTHORIZA ON. P107106 FOR PERMIT „( 9, 06 AUG 2021 sF\',�EDF wnsR� o f N VICINITY PLAN `,(0,,, 0N 0 20 40 80 120 FT. '�II �`�! ��W c o �, MARINE STRUCTURES ENGINEERING,INC. 1- 111111 'k ec.n T o,° �� N S G 1004 COMMERCIAL AVE,#364,ANACORTES,WA 98221(360)466-8627 D S'ONAL E� ry' SCALE: APPROVED RV: ORAWN V: KDL Q0 1,, DATE: AUG '21 REVISED: LAFAVE DECK 0 3810 STERLING PLACE DRAWING HOMER VICINITY PLAN 1 DP 5 OT Og CODECOCA 3 � e {�/. m i iI i ,� 89 EXISTING FENCE / EXISTING �' o II'PROPERTY s'` COI 6' ' / — i o LINE 'uFIELDSe� / �j N II PROPOSED DECK �p i _ 13,0 _ /AND STAIRS EXISTING I (221.5 SQ. FT.) i LOW DECKA o �� (V II 1O II LOT COVERAGE (10,019 SQ. FT.) ______ 1-__ L EXISTING PROPOSED 31.5 39.5 , 1_9.0 j HOUSE 1,623 SQ. FT. 1,623 SQ. FT. r - SIDEWALKS 613 SQ. FT. 613 SQ, FT. DECKS 352 SQ, FT. 441 SQ, FT. I r I 3,039 SQ. FT. 3,128 SQ. FT. I COVERAGE 30.3% 31.2% 0 I IMPERVIOUS 26.8% 27.8% - EXISTING HOUSE I 23 \ .. , P107110 3810 STERLING PLACE EXISTING 0,23 ACRE DRIVEWAY �� 10,019 SQ. FT. ZONE R2 / I / / STERLING PLACE CUL-DE-SAC FOR PERMIT / �`� s,A`q� 06 AUG 2021 o ��*PLOT PLAN ��� MARINE STRUCTURES ENGINEERING,INC. cy -� `/one FG STE• PEo 1004 COMMERCIAL AVE,#364,ANACORTES,WA 98221(360)466-8627 D 0 5 10 20 30 FT. SS/ONA1. '8 (> SCALE AOPaG�ED a.: '"„"" KDL (0 ob PJG E. AUG '21 REVISED: j LAFAVE DECK Q 3810 STERLING PLACE DRAWING NDMRER PLOT PLAN 2 DE 5 0 CEDAR GUARDRAILS ALL SIDES FULL-DEPTH 2 X 8 4 X 4 GUARDPOST ATTACHED low CODE BLOCKING AT EDGES TO RIM JOISTS AND EDGE # 4to 1/2" X 11" COMPOSITE 5/4" X 6" OF SHED IJOISTS PER DCA6 (11 PLACES) G1T Y l FASCIA ALL SIDES 131-0 1/2" COMPOSITE DECK 3 1/4" 4 2 __ 731-0 4 1/2"2 4 2 _ 3 1/4 �� u u " u m Allialk ], x x _A- _C-1 _IXI .tqCO(]b O 11 11 II II II II II II — �_- LL�� 11 SHED 1 SQQ 221.5 S0. FT. BELOW T --7 AFIELD INCL. STAIRS) I I IIII I II II II II II II II an .Z .,.1 9 SLAB w L° EXISTING LOW 2 X 12 NOTCHED w o 53 1[DECK TO REMAIN x STAIR RISERS 1D I °° 1 o 0 te w rn (12" O.C., MAX) N 00 m tO E Q —IX , In _1 Z (0 5/4" X 6" ' I I I I Tr)I I I IQ N COMPOSITE 4- STAIR " " " " " " " n 0 TREADS N + ----1 Lo _ _71 T k A_ 11 11 1 J 11 11 I 1 I T, ' N 7 n rr -I---1 11-4" O II II 11 X O � ,1I I1I I, 1Iu u u u u u u p TYP. '11 L1 _L n-fT -F---11 1 1 I I I 11 ' '11 II I 1 1 Xr 11 E '� N j1 .� 1' 9 1 EXISTING t BAY WINDOW /W/ FOUNDATION l\ ~ / I ' IX EXISTING SLIDING DOOR 1 1 6'-5 3/4" _ 3'-0" __ 10'-0 1/2" _ _ 6'-5" _ 3'-0" __ 10'-0 1/2" 11\e/ 1\1 - - 1\1 EXISTING HOUSE EXISTING HOUSE LATERAL LOAD DEVICE PER DCA6, TYP. (3) TO REMAIN TO REMAIN 2 X 8 PT LEDGER ATTACHED TO HOUSE PER DCA6 AND STRINGERS DECK PLAN DECK FRAMING PLAN ATTACHED TO LEDGER WITH METAL JOIST HANGERS APPLICABLE CODES: 2018 IRC AND DCA6-15 0 1 2 4 6 FT. JOISTS AND BLOCKING - 2 X 8 DOUGLAS-FIR (PRESSURE TREATED) 0 1 2 4 6 FT. GUARDPOSTS AND GUARDRAILS - WESTERN RED CEDAR 1/2"= 1'-0" DECK, STAIR TREADS, TOP RAILS AND FASCIA - 5/4 COMPOSITE 1/2"= 11-0" DESIGN LIVE LOAD: 40 PSF (X 1.5 = 60 PSF) SHED MUDSILLS - 2 X 4 DOUGLAS-FIR (PRESSURE TREATED) SHED FRAMING - 2 X 4 DOUGLAS-FIR SHED SIDING - COMPOSITE T1-11 SHED SHEATHING - 1/2" CDX PLYWOOD SHED ROOF - TRI-PLY #75 BASE SHEET AND SBS GRANULE CAP SHEET CONCRETE - 3,000 PSI MIN. REBAR - GRADE 60 FOR PERMIT 4'''t'-iiiF 06 AUG 2021 N 5 rr. ii'Y 'S MARINE STRUCTURES ENGINEERING,INC. N ' fc?si 5,,,,, 1004 COMMERCIAL AVE,#364,ANACORTES,WA 98221(360)466-8627 sS/ONAL C\'‘ R, SEALE: APPROVED BY. DBAWB BY: KDL Q6 pJG DATE: AUG '21 REVISED: LAFAVE DECK o 3810 STERLING PLACE DECK AANSRAMING DRAWING 5 FOR CODE 4�a T Y LIAot EXISTING HOUSE (BAY WINDOW)-\—i\i--/\i— , n m 15'-7 1/2" _ _ 131-0 1/2" _ 8'-11" __ 3'-8 1/2" _ 711111011k ,13. 4, 1891 CEDAR GUARDRAIL W/ CEDAR GUARDRAIL W/ CEDAR GUARDRAIL W/ ``QCOSL J COMPOSITE TOP RAIL COMPOSITE TOP RAIL COMPOSITE TOP RAIL for.,„ T) Sev et,-CEDAR GUARD 5/4 X 6 COMPOSITE Q ' ' / POSTS AND STAIR TREADS (7 1/2" RISE, 11" RUN) GUARDRAIL COMPOSITE DECK l L_I1_��____u____11_1�_��____u____11 �i I ____u____11__�I_II, • CEDAR HAND II II i rl ~In T{I Ff IT TI hr IIT Ti I I g (-1-, J1r _ _ _RAIL i �I-7-ir----rt----T 11-ir----n----Tr-r+ir----n----T -111JL 11 1 -L� 11 LL l__ LIJ1 1i� II II II II II II II 1 mmm II II II II II II II ' 11- a II II II . I CEDAR GUARD POST, TYP. ;; ;; ;; /-STAIR [SHED o / ;; / TREAD _ NI I" RI N II II II EXISTING HOUSE u.) /-SHED TO REMAIN EXISTING n LOW STAIR f LOW DECK /DECK EXISTING GROUND X SLOPESHEDTO REMAIN GROUND RISER DOOR ,..." TO DRAIN , x x / \\ / \\ / �� CONCRETE 7'-4 1/2" __ T 0" SLAB 14' 0" __ 3'-8 1/4" _ 1' 3"__ T 0" _ _ 4'-4 1/2" __ 3' 0" r CONCRETE SLAB EAST ELEVATION NORTH ELEVATION WEST ELEVATION EXISTING HOUSE / TO REMAIN 4 X 4 CEDAR GUARD POST 5/4 X 6" 2 X 2 CEDAR --- COMPOSITE DECK GUARDRAIL VERTS — 2 X 8 BLOCKING (5 1/4" O.C. MAX.) o 1 X 3 CEDAR Z.' Shed provides 2 X 8 JOISTS GUARDRAIL TOP AND i4 RIPPED 2 X 6 BLOCKING ade uate support (16" BOTTOM RAILS TRI-PLY SBS GRANULE CAP a pp O.C,I� SHEET OVER #75 BASE SHEET `. LATERAL LOAD , Q 2'-0" 2 X 4 PT OVER 2 X 4 and lateral stability DEVICES NOT METAL FLASHING HDPE SCUPPER, TYP. SHOWNfor deck as drawn. I ' I � 2 X 4 STUDS (16" O.C.) Siding nailing to be 6" JOIST HANGER, TYP. 6'-Sli 2 X 8 RIM JOIST / WITH 2 X 4 BOTTOM edges and 12" field 2 X 6 ROOF BEAM 2 X 8 BLOCKING AT TRIMMED TO SLOPE PLATE AND DOUBLE 2 X 8 LEDGER ATTACHED z.,, GUARD POSTS (16" O.C.) 2 X 4 TOP PLATES unless noted TO HOUSE W/ LAG BOLTS METAL HURRICANE TIE o PER CODE Lo ALL JOISTS, EACH SIDE d- JOIST HANGER, f OVER CT PAPER OAR ISIDING WRAP otherwise. d- OF SHED TYP, 1/2"m GALV. IEXISTING GROUND ANCHOR TO REMAIN SHED BOLTS 2 X 4 PT MUDSILL 7' O° SLAB N z CONCRETE I D.G - FOR PERMIT N t7 SLAB 4.4 ;��,, F 06 AUG 2021 0 , I,I/ B DECcsl �'� W MARINE STRUCTURES ENGINEERING,INC. N ECK SECTION SHED SECTION ��F�fD ,°G�a� 1004 COMMERCIAL AVE,#364,ANACORTES,WA 98221(360)466-8627 D s411s/ONAL C"' R, SCALE. APPROVED BY. DRAWN BY KDL Q6 P. DATE: AUG '21 REVISED: - LAFAVE DECK 0 3810 STERLING PLACE NG ELEVATIONS SAND DRAW14NDMaFR 5 low CODE 4� OUTLINE OF FINISHED w� A Y { DECK ABOVE � ZY� -\ - 14' 0" _ — 14' 0" Alai: C 8" _ 2' 0" _ 2' 0" _ 2' 0" _ 2' 0" _ 2' 0" _ 2' 0" �, 891 t� ' I I f RCOjLS -L j j-�- 0 I THICKEND ���FIELDSe� �; = I E. f I f ENDS, EACH 1 / #3 TRANSVERSE #3 LONGITUDINAL \ ` ZD BARS (11 PLACES) - BARS 6" 1'-Ou SLAB LONGITUDINAL SECTION �-o �, N Z L i i I L I I I I V , - I a 10 1-4 1-4 1-4 " ' " ' " ' " 1'-4" 10" FORMED JOINT - o IN CENTER f o - rTHICKEND DGEEACH, E , o a c_i / \ END EXCAVATE TO NATIVE SOIL THEN N INSTALL MIN. 3" OF COMPACTED GRAVEL. 1- 6" 1' 0" rC>. /- ~ PARALLELROUNDEDGES TO SHORTANDLIGHT DIRECTION.BROOM FINISH #3 LONGITUDINAL J #3 TRANSVERSE BARS 19 PLACES) BARS SEAL TOP W/ ACRYLIC CURE AND SEAL. SLAB TRANSVERSE SECTION V V SLAB PLAN 0 1 2 4 6 FT. 1/2"= 1'-0" FOR PERMIT ��D. mt 06 AUG 2021 ,k�'t,a W�sxibq`F` N 4' ,� o :,,11l� •+� F_ OFF qF�T 0.�0 \a4i MARINE STRUCTURES ENGINEERING,INC. (1) B G 1004 COMMERCIAL AVE,#364,ANACORTES,WA 98221(360)466-8627 ss/ONAL C\'‘ R, SCALE: APPROVED BY. BRAWN BY: KDL Q6 pJG DATE: AUG '21 REVISED: — LAFAVE DECK 0 3810 STERLING PLACE CONCRETE SLAB PLAN AND SECTIONS A 5NBMoFR 5