Loading...
HomeMy WebLinkAboutPermit File BLD-2020-0695 3939 Rock Ridge Parkway (2) SUPRIDP INSULATION CERTIFICATION CARD Insulation Contractor Name: SUPERIOR INSULATION PRODUCTS Jobsite Contractor: STRANDBERG CONSTRUCTIONE Jobsite Name: N/A Jobsite Address: 3939 ROCKRIDGE PARKWAY ANACORTES SKAGIT WA 98221 Ceiling Insulation Manufactures Name: Certainteed Knauf Insulation Type: Fiberglass Blown Fiberglass Batts R-Value of Insulation: R49 R49 Thickness of Insulation Installed: 16.25" 13.5" Location of Insulation Installed: Ceiling Area Ceiling Area Exterior Wall Insulation Manufactures Name: Knauf Insulation Type: Fiberglass Batts R-Value of Insulation: R21 Thickness of Insulation Installed: 5.5" Location of Insulation Installed: Exterior Walls Floors Over Unconditioned Space Insulation Manufactures Name: Knauf Insulation Type: Fiberglass Batts R-Value of Insulation: R38 Thickness of Insulation Installed: 12" Location of Insulation Installed: Crawl Space THIS CARD MUST BE POSTED IN A PROMINENT LOCATION AND RETURNED TO THE BUILDING DEPARTMENT BEFORE YOUR FINAL INSPECTION ULL4 GUZMAN SUPERIP833KT Insulation Contractors Signature License# 04,21,2021 Date AINEESEENOI • , With51111KGROW STAITE,liNEWEIKMf p p a 7 te Residential ir uildhrig Air Leakage Test (Blower Door Test) Results Permit * ' ctr., tyAt,a-1' bco Z0e-0 - q House address or lot number: >9 3 c City: Zip: - r Cond. Floor Area (ft2): 1 `- 3 7 Age of house: C) Source (circle one): Pfan Estimated Measured Results shall be reported as Air Changes per Hour at 50 Pascals (ACH60) and shall be calculated as follows: ACH50 = (CFM50 x 60)/Volume Where: CFM50 = Blower door fan flow at 50 Pascal pressure difference Volume = Conditioned Floor Area of the housing unit x ceiling height Blower Door Test Result: I, 5 ACH50 CFM@50Pa Ring (circle one if applicable): Open B C Blower Door Fan Location: 6 c-v f., Weather Conditions: XL' kr I certify that these blower door results are accurate and determined using standard industry protocol. Company Name: {' ' i J i �~7 �� �) Technician: Technician Signature: F'� r� '-_ Date: 7 t Phone Number: Y Zj 'c� r{ 2012 Washington State Energy Code reference: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2, and 3- 5 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Once visual inspection has confirmed the presence of a gasket (see Section 502.4), operable windows and doors manufactured by small business shall be permitted to be sealed off at the frame prior to the test.