HomeMy WebLinkAboutPermit File BLD-2021-0575 3809 37th Drive Y C} City of Anacortes Invoice/Permit#: BLD-2021-0575 904 6th Street Applied date: 07/14/2021 P.O.Box 547 Issue date: 07/15/2021 _ 0, Anacortes, WA 98221-0547 Expire date: 01/11/2023 441 (360) 293-1901 Job Address: 3809 37TH DR Permit Type: PV Solar Permit ANACORTES WA 98221-4421 Project: APN: P80341 Remarks: INSTALL ROOFTOP SOLAR PV SYSTEM,4.16kW WITH AUTO RAPID SHUTDOWN. Owner: JENNIFER BOWMAN Contractor: CAPSTONE SOLUTIONS Address: 3809 37TH DR Address: 8195 166TH AVE NE SUITE 100 ANACORTES WA 98221-4421 REDMOND WA 98052 Phone: (360)299-3766 Phone: (206)741-2203 License#: General Information: Fees: Building Valuation 1694 Building Permit Fee 60.10 Plan Review Fee 39.07 State Building Code Fee Resi 6.50 Total Calculated: 105.67 Deposits/Receipts: 0.00 Total Due: 105.67 The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and examined this application and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY Y o PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location:904 6th Street, Anacortes WA 98821 Y '� 511 Phone: (360)293-1901 FORM BP-1: RESIDENTIAL BUILDING PERMIT APPLICATION 1. PROPERTY INFORMATION Project Address(Street,Suite#): Assessor Parcel Number: 3809 37th Dr, Anacortes, WA 98221 P80341 Subdivision/Lot#: Zoning Designation: Lot area (size): 2,030 sq.ft. N/A N/A 2. TYPE OF PROJECT ❑ New SFR ❑ New Accessory Dwelling Unit: ❑ Deck/porch (new/repair) III New Duplex ❑ Attached to Primary Unit ❑ Interior remodel ❑ Detached from Primary Unit ❑ New Addition to SFR ❑ Garage, carport or accessory building E Fence or retaining wall or duplex (new/repair) Other: Residential rooftop solar PV, 4.16 kW Project Summary: Installation of residential rooftop solar PV, 4.16 kW, with automatic rapid shutdown. Project Valuation: $1,693.99 (labor and racking) 3. PROPERTY OWNER INFORMATION Name:Jennifer Bowman Phone:360-202-7419 Address(Street,City,State,Zip): Email Address: 3809 37th Dr, Anacortes, WA 98221 jbow2@frontier.com 4. CONTRACTOR INFORMATION Name:*Eric Marquette Phone:(360) 325-5345 Contractor's Business Licenses State License#: City License#: *All Contractors&Subcontractors must have a valid City CAPSTS 18830S 60276857-001-0001 of Anacortes business license prior to doing work in the Expiration Date: Expiration Date: City. 09/27/2022 01/31/2022 Address(Street,City,State,Zip):PO Box 715, Email Address:emarquette@capstoneemail.com Redmond WA 98073-0715 5. CONTACT PERSON Select one person the city will contact for anything t6 Applicant ❑ Property Owner ® Contractor related to this project: ❑ Other(list below) Name:Eric Marquette Phone:(360) 325-5345 Address(Street,City,State,Zip): Email Address: PO Box 715, emarquette@capstoneemail.com Redmond WA 98073-0715 Res.Building Permit Application Submittal Checklist Updated October 10,2019 Page 5 of 18 City of Anacortes Photovoltaic System Permit 4si Submittal Requirements Permit Required: A building permit is required for the installation or replacement of solar/photovoltaic (PV) systems, including roof top arrays, ground-mounted arrays and PV water heaters. An electrical permit is required from the State Department of Labor & Industries. Single family residence rooftop installations meeting the criteria in the attached checklist are eligible to obtain a building permit over-the-counter at the permit center in City Hall. CODES: International Residential Code (Current Edition) International Building Code (Current Edition) International Fire Code (Current Edition) National Electrical Code (Current Edition) FEES: Building Permits for installations are based on the material cost of the support system and labor for the installation. SUBMITTAL REQUIREMENTS FOR PV (OTHER THAN ONLINE OR OVER-THE-COUNTER PERMITS): 1) Permit Application Form A. 2) Site plan showing location of house and array/equipment on lot, with setback dimensions to property lines. 3) Roof plan showing the array. 4) Manufacturer specifications or the PV panels and mounting hardware. Include the weight of the equipment. 5) For rooftop systems not conforming to all of the criteria in the attached checklist, provide a roof framing plan and either: a) Structural calculations by a WA State Licensed Engineer or other competent person showing the adequacy of the existing roof structure to support the additional load, or b) Documentation showing that the roof structure was substantially overbuilt compared to prescriptive code requirements. 6) For ground mounted systems provide structural calculations by a WA state licensed engineer or other competent person showing how the structure meets wind design requirements for the structure and footings. Note that ground mounted equipment greater than 36 inches in height must adhere to minimum required property line setbacks of the applicable zoning district. NOTE: The purpose of this handout is to assist the public in complying with detailed permit submittal requirements. It is NOT a complete list of permit or code requirements and should NOT be used as a substitute for applicable laws and regulations. It is the responsibility of the owner/design professional to review the submittal for completeness and applicability to other codes. Only complete applications will be accepted by the City for review. To Be Completed By the Applicant Project Address: 3809 37th Dr, Anacortes, WA 98221 Project Applicant: Eric Marquette Applicant Email:eric.marquettecapstonesolar.com Phone No.: (360) 325-5345 Site Owner Name: Jennifer Bowman PV system Description: Installation of residential rooftop solar PV, 4 .16kW, with automatic rapid shutdown. Determine if your project is eligible for an over-the-counter Permit(Check Yes or No) Yes No 1. PV System is designed and proposed for a detached single-family house,duplex or ® I ❑ town home. 2. PV System is designed for rooftop of house in general compliance with applicable ® ❑ codes. 3. Mounting system is engineered and designed for PV. ® ❑ 4. Rooftop is made from light weight material such as shingles. ® ❑ 5. PV system will be permitted and pre-approved by Labor& Industries Electrical ❑ division. 6. To address uplift, panel are mounted no higher than 18"above the surface of the gi ❑ roofing to which they are affixed. Except for flat roofs, no portion of the system may exceed the highest point of the roof. 7. Total deal load of panels,supports, mountings, race ways,and all other ❑ appurtenances weight no more than one of the following. IF Yes, indicate which: iz No more than three and one half(3.5 pounds per square foot(PSF) o Frameless panels on at least 3/12 pitch roof weighing no more than four and one-half(4.5) PSF o Frameless panels on at least 5/12 pitch roof weighing no more than five(5.0) PSF 8. Supports for solar panels are installed to spread the dead load across as many X ❑ roof-framing members as needed to ensure that no point loads in excess of fifty (50) pounds are created. 9. Attachment to the roof is specified by the mounting system manufacturer. ® ❑ 10. Panels are mounted no higher than the roof ridge or apex of roof(applies only to ® ❑ pitched roofs). Comments: By Checking this box, I certify that all of the information provided on this form is correct. If you answered yes to all of the above questions,your PV installation is eligible for an over-the-counter building permit. To apply please bring in this completed form to our permit center at City Hall for an over-the-counter permit. To be Completed By Staff Project is eligible for over-the-counter permit? ❑Yes ❑ No SCOPE OF WORK , ' r. • r x. -,,,,y�.�,-�— -�. - w PROPOSED NEW 4.16 KW(DC) ROOF MOUNTED f .. ` ' ;: .w ,,„11.1 +- Y OF NACORTES PHOTOVOLTAIC (PV) SYSTEM WITH FOLLOWING EQUIPMENT: 4 `` ' ` 4 '" + (13) HYUNDAI HiD-S32ORG(BK) SOLAR MODULES BUILDING DEFT: {' `= t. • I- : AP' - ED PLANS 2°X2° (1) SOLAREDGE SE5000H-US INVERTER In+ Co�fe AI Jk• •" aiT ���-20Z ® 75 UNIRAC SOLARMOUNT FLUSH RACKING SYSTEM t r *rL _ •• . Ill ■ I . , 444. op 0, . AN SITE SPECIFICATIONS _ _m. I r ,[ "� :j APPROVED PLr S SHALL NOT ELECTRIC UTILITY PROVIDER: PUGET SOUND ENERGY �!', , ELECTRIC SERVICE RATING: 200A • t f' ' ROOF MATERIAL: COMPOSITE SHINGLE ,; ' v = , ' (///:/7:1 _ / / . ASCE 7 10 WIND EXPOSURE CATEGORY: B '� ASCE 7-10 GROUND SNOW LOAD: 25 PSF �.' . ,r. ;� s 7'1: J CAPST9NE ASCE 7-10 WINDSPEEDS (3 SEC GUST IN MPH) . _ SOLAR -RISK CATEGORY I: 100 f /�r� -RISK CATEGORY II: 110 -, / DESCRIPTION DATE REVISION -RISK CATEGORY III IV: 115 / f INITIAL 8.JUL.2021 ASCE 7-05 WINDSPEED: 85 (3-SEC PEAK GUST IN MPH) - f ASCE 7-93 WINDSPEED: 71 (FASTEST MILE IN MPH) �j. I f J f f • --_ CODE AUTHORITY ►f • '•' ell:'''''' Solar Specialist 2018 WASHINGTON STATE FIRE CODE (2018 IFC) , ► t' TAYLOR DISCH 2020 WAC 296-46B (2020 NEC, WITH WAC AMENDMENTS) • � •s. - 2018 WASHINGTON STATE ENERGY CODE (2018 IECC t•� { �` System Engineer • 2018 WASHINGTON STATE BUILDING COD 2018 IB�) "' {•W. ; x 2018 WASHINGTON STATE RESIDENTIAL CODE ,�' ? x - -, TIM WACHTMAN (2018 INTERNATIONAL RESIDENTIAL CODE, WASHINGTON ,r 1. F. 4 w 4:4 AMENDMENTS 2018 WAC51-51-2300 SECTION M2301) • ? ► System Designer 2018 WASHINGTON STATE PLUMBING CODE Z018 UPC � ,i. ,. # . x`•'�i + � , '2018 WASHINGTON STATE MECHANICAL CO E (2018 MC) �' `= f 't -.b JCASEY MILLER '. , • 4. . :a.. ` Customer Info SHEET INDEX Pf 1OTOVOLTA/G NOT S JENNIFER BOWMAN ZO.ALL WIPING CONGEALED IN AND CEILING SPACES SHALL DE IN METAL GONDU 3809 37TH DR 21,,THE5E151.11G0PAGINGANDANCHOPAGEOFELECTRICALCONDUITSSHALLTEINACCORDANGEWITHTHE ANACORTES,WA 98221 A-1 NOTES, INDEX, SITE INFO, PROJECT DATA, CODE "511AGNA"-GUIPLINE5 POP 5E15111C POSTPAIN5 or MECHANICAL 5Y5TE115 AND PLUMING PIPING 5Y5T-E115, PARCEL#.P80341 r,AN INVEPTEP OP AN AG MODULE IN AN INTEPACTVE PHOTOVOLTAIC 5Y5TEM SHALL AUTOMATICALLY DE-ENERGIZE IT5 22,ALL OF THE LISTED 5Y5TE1'15 PEQUIPED THAT THE 5EI5111C LATERAL FOPGE P INCLUDING CONSIDEPATION OF o"P AND OUTPUT TO THE CONNECTOO ELECTPICAL PPODUCTION AND D/STPIOUTION NETWORK UPON LO55 OF VOLTAGE IN THAT LAP DE DETEPMINED AT EACH LEVEL OF THE DUILDINO 50 THAT DPAGE SPACING CAN DE CALCULATED.THE DISTRICT Project Details A-2 SITE PLAN 5Y5TEM AND 51ALL REMAIN IN THAT 5TATE UNTIL THE ELECTRICAL PRODUCTION AND D/STPITUTION NETWORK VOLTAGE STRUCTURAL ENGINEEP CAN APPPOVE THE 5E1511C LATEPAL FORCE DETERMINATION. 11A5 PEEN PESTOPED,(NEC 69036/) 23.A COPY OF THE C1705EN DPACING 5Y5TTY1(5)INSTALLATION GUIDE/MANUAL SHALL DE ON THE JOT 5/TE PRIOP TO 4.16 KW A-3 PV LAYOUT AND COMPONENT LOCATION 2.ALL EXTEPIOP OLOGTP/GAL METALLIC TUT/NG(EMT)CONDUIT PITTING SHALL TO PAIN TIGHrTHPEAD-LE55 STAPTING THE/N5TALL/NG OF HANGERS AND/OP TRACES ROOFTOP PV COMPPE55/ON TYPE, 24.WHEN INSTALLING DRILLED-IN ANCHORS AND/OP POWDER DPNEN PINS IN EXISTING NON-PPE5TRE55ED 3.MODULES AND SUPPORT STPUCTUPES SHALL TO GROUNDED REINFORCED CONCRETE,U5E CAPE AND CAUTION TO AVOID CUTTING OP DAMAGING THE REINFORCED TAR5.WHEN SYSTEM E-1 ELECTRICAL LINE DIAGRAM 4,NAMEPLATES SHALL 0E PROVIDED POP ALL GIPCUIrI IN TOT SEPVIGE D/Sr/DUTION AND POWEP D/STPITUTION INSTALLING THEM INTO EXISTING PPE-577E55E0 CONCRETE TENDONS TY USING A NON-DESTRUCTIVE METHOD PPIOP SWITCH DOAPDS,PANEL DOAPDS,DISCONNECTING SWITCHES,TEPMINAL GADINETS,ETC,ALL NAMEPLATES SHALL TE TO INSTALLATION,EXEPCISE EXTPEME CAPE AND CAUTION TO AVOID CUTTING OP DAMAGING THE TENDONS DUPING TILT E-2 LABELING INFORMATION PEPMANENTLYATTACHEDANDDEOFSUPPIGIENTCAPACITYTOWITHSTANDTHEWEATHEP, INSTALLATION,MAINTAINAMINIMUMCLEAPANCEOFONEINCHTOWEENTHEPEINPOPGEMENTANDTHEDRILLED-INANCHOP, 5,JUNCTION DOX/COMDINER DOX HAVE TO U5E COOPPE55/ON TYPE STRAIN RELIEF PO5/TIONED FOP APPROPRIATE 25,THT WOPKING CLEAPANCES AROUND TOT EXISTING ELECT-PIGAL EQUIPMENT A5 WELL A5 TOO NEW ELEGTRICAL 18.43°/4 12 PITCH WATEP RUN OFF. EQUIPMENT-WILL DE MAINTAINED IN ACCOPDANGEWIT/NEC 11026, AZIMUTH E-3 EQUIPMENT: PV MODULE SPECIFICATION SHEETS 6,CONDUIT PUNS 5HALL DE PROVIDED WITH SUPPIGIENT WEATHERPROOF PULL DOXES OF JUNCTION TOX/COMDINER 26,CONDUCTOPS EXPOSED TO SUNLIGHT SHALL TO LISTED A5 SUNLIGHT PE5/STANT(NEC 300,6 01,3108 DJ PDXES PEP APPROPRIATE NEC REQU/PE IENT5 27,GROUNDING TUS//NGS APE PEQUIPED AROUND PPE-FUNGIED GONGENTPIC KNOCKOUTS ON THE DC 5/DE OP THE 270 E-4 EQUIPMENT: INVERTER SPECIFICATION SHEETS 7.SEEPROVIDED CUT SHEETS FOP ADDITIONAL EQUIPMENT SPEUP/CATIONS 5Y5TE1V(NEC 230.97) 8.WIRING MATERIALS SHALL TE SUITATLE FOP THE 5UN EXPOSURE AND WET LEGATIONS.FIELD APPLIED PROTECTIVE 28.T11E GROUNDING ELECTRODE CONDUCTOP MUST TE PROTECTED FPOM PHYSICAL DAMAGE IF SMALLER THAN#6 DC SYSTEM RATING EQUIPMENT: DC/DC POWER OPTIMIZER COATING5 APE NOT ACCEPTATOT. COPPER WIPE(NEC 230.64 0) E-5 9.JUNCTION,PULL AND OUTLET TOXES LOCATED Of HIND MODULES SHALL TE 50 INSTALLED THAT THE WIPING 29.GROUNDING ELECTRODE CONDUCTOP WILL TE CONTINUOUS,EXCEPT FOP 5P1-CE5 OP JOINT-5 AT TU50AP5 WITHIN 4.16 kW SPECIFICATION SHEETS CONTAINED IN THEM CAN TE PENDEPED ACCE55100E DIPECTLY OP TY DISPLACEMENT OF MODULE(5)SECURED TY LISTED TOUIPMENT.(NEC 250.64 C) PEMOVATLE PASTENEPS AND CONNECTED TY A PLO/COLT WIPING 5Y5TEM,(NEC 69034) 30.PACEWAY FOP GROUNDING ELECTRODE CONDUCTOR 51ALL Of TONDED AT EACH END.(GEC 250.64(E) AC SYSTEM RATING EQUIPMENT: RACKING SYSTEM, ROOF 10,1NANUNDEPGPOUND PHOTOVOLTAIC 5Y5TEM,THE POWER'SOUPCE51ALLTOLATELED WITH THE FOLLOWING 3I.WHEPE ALL TEPPIINAL-5 OF THE 015CONNECTING MEAN5 MAY Of ENEPGIZED IN THE OPEN P050-10N,A 5IGN WILL DE S-1 WARNING AT EACH JUNCTION TOX,GOMTINEP TOX,DISCONNECT AND DEVIGEWHEPE THE UNGROUNDED GIPGUITS MAY TE PROVIDED WARNING OF THE HAZARD PEP NEC 690.1734.EACH UNGROUNDED CONDUCTOR OF THE MULT-WIPE TPANCH 5.0 kW ATTACHMENT EXPOSED DUPING SEPVIGE;"WARNING-ELEGTPIG SHOCK HAZARD,TOO CUPPENT CIPGUIT GONDUCTOPS OF 71115 C/PGUIrWILL TE IDENTIFIED PEP PHASE AND 5Y57-EM PEP NEC2/0,5, PHOTOVOLTAIC POWER'5Y5TE11APEUNGPOUNDEDTUTMAYTOONEPGIZEDWIrIiTOOPESPECTTOGPOUNDDUOTO 32,G/PGUITSOVEP250VToGPOUNDS/LL COMPLY WITH NEC25099 8 230 92IT)8LANG93250,97, ESTIMATED ANNUAL PRODUCTION EQUIPMENT: RACKING SYSTEM, ENGINEERING LEAKAGE PATHS AND/OP GPOUND FAULTS."(NECE 69035(F)) 33 DC CONDUCTOPIT EITHEP DO NOT ENTEP THE TU/LDING OP APT PUN IN METALLIC PACEWAYS OP ENG1-05UPE5 TO THE S-2 11.ALL PHOTOVOLTAIC C MODULES AND A550GlATED EQUIPMENT AND WIPING MATERIAL SHALL DE PROTECTED FROM ANY34,ALL METALLIC PP M PAILS AND OT EP CUPPENT GAPPYINO METALUG COMPONENTS(CONDUIT.JUNCTION 8 PULL 4,400 kWh/Yr STAMP PIOY5 CAL 12.ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT 51ALL OE LISTED TY AN APPPOVED TESTING AGENCY. DOXES,RACEWAY,ETC)SHALL DE SOLIDLY GROUNDED PEP THE MANUFACTURER'S INSTALLATION INSTPUCTIONS LANG Drawing S-3 EQUIPMENT: RACKING SYSTEM, CLAMPS r3.OUTDOOR EQUIPMENT-SHALLTOATLEASTNEMA3PPATED. 93,690J/03893,1103(0), 14.ALL SPECIFIED WIPING 15 CASED ON THE U5E OF COPPEP 35.SCREWS,NUT5,DOLT5 8WA5OER5 THAT ATTACH EQUIPMENT GROUNDING LUGS SHALL DE 5TA/NLE55 STEEL 1.-AMC 15,CONTPACTOP SHALL OTTAIN ELECTRICAL PEPMIrI AND SHALL COORDINATE ALL INSPECTION,GOMMl55IONING AND 93.1/03(D), NOTES, INDEX, SITE INFO, S-4 EQUIPMENT: RACKING SYSTEM, RAIL ACCEPTANCE WITH TOT CLIENT,UTILITY GO.AND CITY INSPECTOPITA5NEEDED 36.NO PIPING,DUCT5 OP EQUIPMENT FOPEIGN TO ELECT-PICAL EQUIPMENT 511AL-1-Of PEP!1 ITTED TO OE LOCATED WITHIN PROJECT DATA, CODE /6,DRAWINGS APT DIAOPAMMATC ONLY,POUTING OF PACEWAYS SHALL TO AT TOO OPTION OF THE CONTPACTOP UNLO55 TOT DEDICATED SPADE ADOVE TOT ELEGTRCAL EQUIPMENT. EQUIPMENT: RACKING SYSTEM, ENGINEERING OT/EP✓✓I5E NOTED AND SHALL TE COORDINATED WITH OTHEP TPADES, 31.ALL FIELD INSTALLED JUNCTION PULL AND OUTLET TOXED LOCATED TEHIND MODULES OP PANEL-5 SHALL DE S-5 /I,IF DISTANCES OF GATLE PUNS APT DIPFEPENT THAN SHOWN,THE CONTPACTOP SHALL NOTIFY ELEGTPIGL ENGINEEP ACCE55/TLE DIPECTLY OP TY DISPLACEMENT OF A MODULE(5)OP PANEL(5)SECURED TY PEMOVATLE FASTENERS. Sheet STAMP TO VALIDATE THE WIPE 5/ZE,PINL DPANINGS WILL TE PED-LINED AND UPDATED A5 APPROPRIATE 38.REMOVAL OF A DWP-INTERACTIVE IN✓ERTEP OP OTHEP EQUIPMENT SHALL NOT DISCONNECT THE TENDING 18.WHENEVEP A D/SCPEPANGY IN QUANTITY OP EQUIPMENT,API5E5 ON THE DPANINGS OP SPEGIFIGATIONS,THE CONNECTION TOTWEEN THE GPOUND/NO ELECT-POPE CONDUCTOR AND THE PHOTOVOLTAIC 50URCE AND/OP OUTPUT EQUIPMENT: RACKING SYSTEM, SITE SPECIFIC CONTRACTOR SHALL DE RE5PON5/0LE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SEPVCES PEQUIPED 0YTHE G/PGUIT GROUNDED CONDUCTOP, S-6 5TP/CTE5T CONDITIONS NOTED ON TOT DRAWINGS OP IN TOE SPECIFICATIONS TO ENDURE COMPLETE COMPLIANCE 39,THE ROOF MOUNTED PHOTOVOLTAIC MODULES,PANEL5,OP 5OLAP VOLTAIC POLL POOPING MATEPIAL SHALL HAVE ENGINEERING AND LONGEVITY OF TOT OPEPADLE SYSTEM PEOUIRED DY THE APCHITECT/ENGINEEP. THE SAME OP TETTEP LISTED PIPE-PE5I5TANGE EATING THAN THE TUILDING POOP-COVEPING MATEPIAL, A_ I IS.ALL DPOCOURES,OPERATION MANUL5,CATALOGS,51OP DPAN/NGS,OTC.51LL TE HANDED OVEP TO THE OWNER'S 40.ALL POOP MOUNTED CONDUIT WILL TE A MINIMUM 1"OPP TOO POOP SUPPAGE S-7 EQUIPMENT: RACKING SYSTEM, BILL OF MATERIALS PEPPESENTATI✓EAT THE COMPLETION OPWORK. Anacortes Cap iLOT p1-AN //1771POO PL/N 1 SCALE: 1/16'= 1-0" A-2 2"X2° AHJ APPROVAL STAMP ® iikke c, 93809 37th Dr, (N) SOLAREDGE SE5000H-US INVERTER(OUTSIDE) INTEGRATED DC DISCONNECT CAPST, NE =- EQUIPPED WITH AUTOMATIC RAPID SHUTDOWN Ar�acortes,WA 98221 SOLAR C (E) UTILITY(NET) METER DESCRIPTION DATE REVISION 1 _ INITIAL 8.JUL.2021 1 (E) MAIN SERVICE PANEL(INSIDE) N INV r �P Solar Specialist XI 77NO / TAYLOR DISCH e� D1'NVWAY 0 --, r System Engineer tf ir >,z �� �— / TIM WACHTMAN �r �(,� ��-)-� �( ) >� ((�" System Designer - - >� ( r ) ) �J� CASEY MILLER (� h >� �� j� �- J-JJ Customer Info ! 1 ► Illlill �J� c � � �v �-{ _i --- �. J-/J �J JENNIFER BOWMAN r 7y -— ,v/ L- j-JJ 3809 37TH DR ��_ i_11111 ) ANACORTES,WA 98221 rat * � PARCEL#.P80341 gilt I I I I Project Details $ 4.16KW kW.- - c,. el A ROOFTOP PV _ HHH } _ TILT $i ' • _ , 18.43°/4 12 PITCH E a . - -r J AZIMUTH �tllsw _ Z7o° * r, I I ' ' DC SYSTEM RATING 3809�371h'Dr, _ A �^ Anacortes,WA 98221 III I I ARRAY I 4.16 kW . (13) HYUNDAI HID-S32ORG(BK) SOLAR MODULES PROPERTY LINE �� `y.," _1I. (13) SOLAREDGE P340 DC/DC POWER OPTIMIZER (APPROXIMATE-NOT FOR LEGAL USE) AC SYSTEM RATING `S'•. - -- - 1 *EVERY MODULE WITH I POWER OPTIMIZER 5.0 kW C.I rz " .�• _ C ESTIMATED ANNUAL PRODUCTION -1E // o \`-t 4,400 kWh/Yr --} �� Drawing i #7::: ,�;„� / f 1 _1 SITE PLAN @Ma {_ . r. t t �� N Sheet I s, �' 0 141 ,"P - _ SCALE: 1/16"-V-0" (IN FEET) 6 I fr , _, ..ti• _., � ' w s. ...... `^ '• Know what's below. A...2 /' „� r t C811 before you dig. 0 8' 16' 32' 1 POO PLfN l lOOUL 5 NOTE TO PV INSTALLERS: MOUNTING CALCULATIONS 1. ATTACHMENTS MUST BE INSTALLED PER MANUFACTURERS A MOUNTING SYSTEM AND MANUFACTURER UNIRAC SOLARMOUNT FLUSH A-3 SCALE: 1/8"= 1'-0" SPECIFICATIONS, REFER TO INSTALLATION GUIDE ON S-1. B TOTAL WEIGHT OF MODULES,RAILS,ATTACHMENTS,&OPTIMIZERS 643 2 LBS 2. LOCATE RAFTERS/TRUSSES LOCATIONS. MODULE WEIGHT(40.I(X NUMBER OF MODULES 13 521 3 LBS 3. BACKFILL ALL PILOT HOLES WITH SEALANT. OPTIMIZER WEIGHT(1.4)X NUMBER OF OPTIMIZERS 13 I82 LBS 4.ATTACHMENTS MUST BE LAG MOUNTED INTO RAFTERS/TRUSSES. 2"X2" 5. DRIVE LAG BOLT UNTIL ATTACHMENT IS FIRMLY IN PLACE. RACKING COMPONENTS 219 Bs AHJ APPROVAL (N) SOLAREDGE SE5000H-US INVERTER (OUTSIDE) WHEN THE PROPER TORQUE IS REACHED,THE EPDM RUBBER c ATTACHMENTS WEIGHT(I.8)X NUMBER OFATTACHMENTS 26 468 LBS STAMP INTEGRATED DC DISCONNECT BACKING ON THE SEALING WASHER SHOULD EXPAND BEYOND D WEIGHT PER ATTACHMENT POINT(B/C)IPOINTLOAD) NOT TO EXCEED 45LBS 24.7 LBS EQUIPPED WITH AUTOMATIC RAPID SHUTDOWN THE EDGE OF THE METAL WASHER. DO NOT OVERTIGHTEN. E MAXIMUM RAIL CANTILEVER 16 IN 6. INJECT CHEMLINK DURALINK 50 SEALANT INTO PORT UNTIL SEALANT EXITS BOTH VENTS. F TOTAL SURFACE AREA OF PV MODULES I 88 SO FT X MODULES 232 4 SO FT (E) UTILITY(NET) METER G DISTRIBUTED WEIGHT OF PV MODULE ON ROOF(B/F)(DEAD LOAD) 643 24 LBS/232 4 SO FT 2.8 PSF (E) MAIN SERVICE PANEL(INSIDE) \ _.... lililLs.-- CAPSTcNE um INV SOLAR 1 ,SP DESCRIPTION DATE REVISION INITIAL 8.JUL.2021 I Solar Specialist 0 TAYLOR DISCH SOLADECK JUNCTION BOX,TYP. System Engineer ELECTRICIAN TO DETERMINE FINAL TIM WACHTMAN 1 JUNCTION BOX LOCATIONS IN FIELD System Designer CASEY MILLER ■ Customer Info JENNIFER BOWMAN 3809 37TH DR ANACORTES,WA 98221 PARCEL#.P80341 Project Details (N) (MY:26)ATTACHMENT POINTS,SPACED EVERY 48", 4.16 KW LAG MOUNTED AND SEALED WITH CONDUIT 3/4",TYP. ROOFTOP PV CHEMLINK DURALINK 50 SEALANT, ELECTRICIAN TO DETERMINE FINAL SYSTEM PER MANUFACTURER'S SPECIFICATIONS,TYP. CONDUIT LOCATIONS IN FIELD TILT ARRAY 1 31'-11" 10 0 18.43°/4 12 PITCH (13) HYUNDAI HiD-S32ORG(BK) SOLAR MODULES AZIMUTH (13) SOLAREDGE P340 DC/DC POWER OPTIMIZER 270° *EVERY MODULE WITH I POWER OPTIMIZER o 0 0 0 o p o DC SYSTEM RATING 4.16kW 0 0 0 0 0 AC SYSTEM RATING 5.0 kW 4' TYP. ESTIMATED ANNUAL PRODUCTION f 0 0 0 0 4,400 kWh/Yr Drawing o 0 0 0 0 PV LAYOUT AND 7 3' TYP. 3' TYP. COMPONENT LOCATION 811 , t Sheet FIRE SETBACK,TYP. SCALE: 1/8"=1' 0" (IN FEET) Know what's below. - 17'-1 I" - A...3 Call before you dig. 0 4' 8' 16' CONDUIT WIRE RATING DERATE FOR TEMPERATIRE ISC WIRE VOLTAGE DROP CALCULATIONS RUN AMPS VOLTAGE VOLTAGE VOLTAGE LENGTH DROP DROP% AT LOAD A 3/4"PVC SCHEDULE (3)8 AWG THHN 11)8 AWG Cu TEMPERATURE DE-RATING @ 104°F= ISC x 1.25 x 1.25= 8 AWG OK Bond Conductor 8 AWG RATE 90°C=SSA SSA x 0.91=S0.05A IAW NEC Vd= x 17.9 x 50'=1290 x 25A=2.34 volts 50 25 1.95 0.81 238.05 IF 1-WAY LENGTH OF CIRCUIT EXCEEDS 50' 40 CONDUIT (Black,Red,White) (Green or bare) 0.91 15.52A 16510 690.8(B)) ) RECALCULATE Vd TO VERIFY LIMITS B /3 (2) 10 AWG THHN III 8 AWG Cu 10 AWG RATE 90°C= TEMPERATURE DE-RATING @ 104°F= ISC x 1.25 x 1.25= 10 AWG OK 2 x 12.9 x 50'=1290 x I SA_ IF 1-WAY LENGTH OF CIRCUIT EXCEEDS 50' 2"x2° "EMT CONDUIT (Positive,Negative) Bond Conductor 30A 0.91 30A x 0.91=27.3A 15.52A IAW NEC Vd= 10380 1.86 volts 50 15 1.86 0.78 238.14 RECALCULATE Vd TO VERIFY LIMITS (Green or bare) 690.8 IBI11I AHJ APPROVAL C PV IN MINIMUM 1 OAWG Cu POSITIVE, BARE Cu EGC OR STAMP AIRWIRE OR THHNFREE IN (90°RATED)WIRE NEGATIVE INSULATED EGC IN CONDUIT CONDUIT CONTROLLED CONDUCTORS ARE LIMITED TO: (1) STRING OF (1 3) HYUNDAI HID-S32ORG(BK) MODULES - • NOT MORE THAN 30 VOLTS AND 240 VOLTAMPERES WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION SolarEdge Power Optimizer P340 CONNECTED IN SERIES OUTSIDE THE ARRAY. UTILITY METER ' NOT MORE THAN 80 VOLTS AND 240 VOLTAMPERES WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION DC Input Power: 340 watts v INSIDE THE ARRAY. Maximum Input Volta e: 48 Vdc BI-DIRECTIONAL (NET) p g THE RAPID SHUTDOWN INITIATION IS PERFORMED BY EITHER DISCONNECTING THE AC FEED TO THE INVERTER, MPPT Range: 8 to 48 Vdc CL 200, FM2S, 60Hz OR-IF IBL g 1 2 12 13 CAPST NE THE INVERTER DC SAFETY SWITCH IS READILY ACCESSIBLE-BY TURNING OFF THE DC SAFETY SWITCH. Maximum Short Circuit Current (Isc): 1 1 Adc O O O O 1-PHASE, 3W, 1 Z0/240V METER#: H56719189 Maximum Output Current: 15 Adc per string ROOFTOP PV CONDUCTORS TO BE I" SOLAR PHOTOVOLTAIC SYSTEM EQUIPPED WITH Maximum Output Voltage: 60 Vdc ABOVE ROOFTOP AND PROTECTED _ INVERTER-EMBEDDED AUTOMATIC, RAPID SHUTDOWN _ FROM PHYSICAL DAMAGE VIA _ DESCRIPTION DATE REVISION Limitations: 8 to 25 Optimizers per string + - + SECUREMENT WITHIN ARRAY + - + INITIAL 8I .JUL.2021 1 Maximum Power Per String: 6000W BOUNDARY OR 3/4"CONDUIT. I I IALL ELECTRICAL MATERIALS&EQUIPMENT - - SHALL BE LISTED BY APPROVED TESTING LAB = = = = JUNCTION BOX A A DC DC 1000V,NEMA 3R, UL LISTED OR 0 0 0 DC DC APPROVED EQUAL A + _ + __ + = + Solar Specialist n ,- TAYLOR DISCH 2 P 30A PV AC Il E System Engineer BREAKER L TIM WACHTMAN CDB MIPVNIMUIRE M I OAWG Cu(90'RATED)WIRE POSITIVE,NEGATIVE 0 O BARE Cu EGC OR INSULATED EGC IN CONDUIT e MAXIMUM 2%VOLTAGE DROP CASEY MILLER Customer Info - . m /� JENNIFERBOWMAN / \v, 3809809 37TH DR ANACORTES,WA 98221 c ELECTRICAL INSTALLATIONS PARCEL#:P80341 O +- WILL COMPLY WITH THE Project Details + REQUIREMENTS OF THE i I ��1 ^ O - - NEC.SEC 690&705 4.16 KW D ii I = Note:705.3 I ROOFTOP PV Note:705.121B1121)3)(b) SYSTEM _1 SOLAREDGE SE5000H-US Note:312 6&3)2 8(A))I)&(2) Note:4046 Exception TILT MAIN SERVICE OUTPUT: 21A @ 240V Note:230.66&230.70(C) I8.43°/4:12 PITCH PANEL NEMA 3R, UL LISTED, Note:310.15(3))c) INTERNAL GFDI Note:250 24(B) AZIMUTH 200A BUSBAR Note:314 16 270° 200A MAIN OCPD INTEGRATED DC Note:690.12(C) DISCONNECT WITH RAPID DC SYSTEM RATING SHUTDOWN KIT 4.16 kW AC SYSTEM RATING 5.0 kW Module Information Inverter Specifications Conductor Calculation Interconnection Method I ESTIMATED ANNUAL PRODUCTION SOLAREDGE SE5000H-US 4,400 kWh/Yr PV MODULE: HYUNDAI HiD-S32ORG(BK) MAX BRANCH DC CONDUCTOR AMPACITY: SOLAR CIRCUIT CONNECTED INTO EXISTING 200A Drawing 320W x 13=4160W/380V=10.95Ax 125%=13.14A MAIN SERVICE PANEL WITH NEW 2P30A SOLAR ELECTRICAL DATA PER MODULE (STC): RATED/MAXIMUM AC POWER OUTPUT: 5000W P340 MAXIMUM OUTPUT CURRENT= 15A BREAKER (OCPD) TO BE INSTALLED AT OPPOSITE MAX. CONTINUOUS OUTPUT CURRENT: 21 A 10 AWG Cu 90°RATED=40A 91 =36.4A 1 =36.4A END OF BUSBAR FROM OCPD PROTECTING THE ELECTRICAL LINE DIAGRAM MAXIMUM POWER-Pmax (Wp): 320 I I- I (- MAXIMUM POWER VOLTAGE-Vmpp (V): 33.7 MAX.DC INPUT POWER: 7750@240V 36.4A>-13.14A OK TO INSTALL IAW NEC 690.8(13)(1-2) BUSBAR NEC 705.12(B)(3)(2) MAXIMUM POWER CURRENT-'mop (A): 9.57 MAX. INPUT VOLTAGE: 480V MAX BRANCH AC CONDUCTOR AMPACITY: 200A RATED BUSS x 120%=240A-200A MAIN OCPD=40A _ Sheet OPEN CIRCUIT VOLTAGE-Voc (V): 40.6 NOMINAL DC INPUT VOLTAGE: 380V 25A MAXIMUM CONT. OUTPUT CURRENT 2P30A BREAKER OK MAX. INPUT CURRENT: 13.5A@240V 25A x 125%=31.25A INSTALL PERMANENT LABEL ADJACENT TO THE BACK-FED BREAKER E- 1 SHORT CIRCUIT CURRENT Isc (A): 10.04 WITH FOLLOWING OR EQUIVALENT WORDING: 18 3% CEC WEIGHTED EFFICIENCY: 99% 8 AWG Cu 90°=55A x.91=50.05A x 1=50.05A WARNING:POWER SOURCE OUTPUT CONNECTION.DO NOT MODULE EFFICIENCY: MAX. EFFICIENCY: 99.2% 50.05A>-31.25A OK TO INSTALL IAW NEC 690.8(B)(1-2) RELOCATE THIS OVERCURRENT DEVICE. 0/v1vOOi y 01 CJ00190c1i O9 aga Nome 211 JO/ -IOv 70d 211 01 AI NVH13210W 38 ION 11VHSN SONIN18V 3 80d S138V1S AN33/16138 9NIDVdS'S80013 80'S9NI1133 Z 3 9n /-! 60 1�l 1 �l ni0 �1 I/ n "SN0111SVJ83Sl11..%H321f13 1)3 A88NOIIVTIVWNI 213 3V 311913H3 1 VHS SONONVI3 83 S139 �1 n n .:J/ � /N/�A9 /1�G�1'>y� /Y.i�I/O��//ci0nG/ � / Y1n22iv 1 v/�1 311H/X�"3SV9213dd(1.E Hll/X�3n11�31d321'NOI1VllV1SNl 21313V 318151/�38 llVHS 59NIN21VW NO SlO 38Vl 9 e d2dd09 0/ /O/ /N/1N09 01 020NOO 26c/01 1IVO 1cYOdd00 01/ 000 6 -835(1Nf1 321V S9NIN3d0 lIr1aN09 318V11VAV 3H1 'NO/l9n015N/5,02011l9VdnNVGI JO ANV HJIHA\NI S318091U18NOJ'S3X08 NOIIJNflf R S3X08 llfld 3O S32111SOlJN3 NO 5213/l0D 'SOOH131A1 9NINSIl 213H10'4 SAV211318V9"SAV/1139V21 a3503X3'S21O19llONO911f19211J 9a W31SAS (E)(0)99.069 ON 4aaNs 0/19 9NICINn009 201020`0/VO10Oddn0 21000G4 CINV 21IVOl (V)'g(E)(J)6E'069 03N 21n00G1 N22M120 0O11V15N120 01 Shc19 9NIONn009 21000Gl"9 d D d n O S d d M O d W 31 S A S Ad N011t/W?IO�NI 9N1138tf1 218/S/A,(1ICIV2�' HV1OS HOd HDIIMS C/NV 02120V7 A1O1V/0'd00d0V 20-71V1-iS 0NO/1VN/GI02120/M 11V'6 )I V11 OAOIO H d :9 N I N d VM NMO a1f H S O l d VH 6uinneaa '419N/00099V GI21-1l 2Z/s-71V1-1S J010V01N00 21-11`02/0/O2ds ION 20V 51/n/N09 CINV`5,(VM29V0"52)(00 NO119Nnr JO 52Z15 2021-IM'9 JA/Lom oot't 'OCIOVON1/15 NOII)fGO?Jd 1VnNNV a31VWIIS3 C/NV 52009 218/V9/1d0V 11/01n0 01 02/0000299V CINV 09N/11/0 /m us 511000n5`51211n0 40V00292N 77V 1-15/NOIO 11VU5 0019V01N09 tl DNIIV?J W31SAS DV "SGI215,(5 JO 1N2GIOONVIIV 1V02N29 20121VOION/59N/MVIQ'9 AA)1 9I "9Z"O11 92N U1/M 41d1I0911VU51N2GIdln02 5555 5 MISASAd (e)( )(0)99'069 03N 1V0/019212 9N/1 /Y2 ONV NON 7NV CINnOJVS2ONV0V210 9NIM0/M h a",°5 a°'"'l1M5 M°°lHS°dda 9NI1Vel W31SAS Da AV23H V 3Hl NI I ",(2NOVA BO`d/U`290l0'126'V2N JI)2IlOS 2iRMOd avzvH>10oHs OLZ � W30fO32 ONH 2/-/101216/ 0d5V 2010O021V001 ONV 01411920/0 021000 DIV11OA010Hd '9NIN21VM AS Ad NMOOlfHS H1nWIZf/ „�, os 01 NOIlISOd„dd0„ 2�/77VUO Od010000 NO C/21NnOGl O(V/VI OV0 C/NV 1/nC/NOO"9N/�f/M"� '8 C O 6E'069 0f�3N 7 3Hl Ol HO1IMS HD11dz1 b/.Et 81 1N2GINO0//�N2 12/9 220920 NMOOlfHSOIdV NMOQ11 HS H NHl1 1111 06(INV A 009 0'Od 021VI"02dd09 2011VU5 50'019nCINO9 71V"Z W31SAS 'NO/1V9/Od0VO1/ GIdV21 H11M ERddlflOA I NMOalnHS GIdV 1 H11M Ad doldoo2J d'O0 02120V7 CINV`01./N J21-1 110 JO 1n 48 025/1 20 01 1N2GId/n0211V "l N I)]SAS V11OAOIOHd 1 a3dd11103 W31SAS Ad bb'10S /AN 91 iz 99'069 03N [CI'1G(09 9.01NV_L I g !1.Gl1VVM 1Q sllelaa TJafo.ld 1-71/11 5N9/S-7,(NI/I'OgJg1-10V,(71g10J19/3-7 JV11399V 9 7.(VG;SN9/S 03N31SV9 gNSg11OV- 117E08d #1dD?JVd TONIY,W110-73/9C01Z'011931\1]-/1(11Z/ NV141/M,(7d1,109(1700u559N/-9'VGJMEM 1N32121n3 lInmo WnWIXVW 17786 VAI\"S311O3VNV C1NV"SON//WVM"'0 X/V-7 031-711V 6-73I9-7-7V`3009 S/G1I Nl39'3G1M3s-73 031/n09d gJ'1-1M Dpn 0817 39d11On wnwIxt/w 210 RULE 608E 'C1307V15N1 Sl1l313uM1NOGINO4/W9'31-119OU 07OV1lns 31-1-7/Vus 39QV7 31-11- ID3NNODSIa Da DIV11OAO1OHd NVA/A08 2J3dINN3( 'S1\19/5OONOISVV g/VS3/-I0V ()Jul laWolsn3 E9'069 03N dd-11IWAdSbD.1au61saa uaais�CS A1N013NNOSH3d a3IdI1VflO A9 43O1A/A3S NVWIHDVAA WIl Jaaul6u3 ulalsAS -MM 103NN00SIa 2OIA I3S (Q)(E)(Z)(8)z1:90L 03N HIVO 21O1AV1 --- 3O 3GIS llddrIS 013GVW , '30In30 • iS!I2DadS J?IOS --- SI N01103NN03eI 1NI 1NSHHfl02f3n0 SIH1 --- Ad dl a2 lIn03 1 SY 31b00132i ION n� d`dl d a I S Al d d S O4'N01103NN00 lndln0?J31�13nN1 (E)(8)Zl'90L03N "'"a"M" ONIN�Ib�M ��!II�i! 117 1 l Zoz'lnr8 1VIIINI Wd1SAS 3IV110AOIOHd SI 8-21A0S GNO93' ■u:II■• = . NOISI/1321 31V0 NOIldRoS30 •u:II•F 3ndi• . u•. ,ii NI . . 11ir ■u:IIm Nun v TI Q S ZV90L 03N V(8)1Z 06l- 03N Emu ^^ 1�(8)El"069^^0�3+N 3�O.ISdV N. o 13NVd 30ISNI ONIN IOM , ca EnNun 1.J�NNO.JSIQ `'� 01210I21d 1O3NNOOSIa OV Ell /0 OIV110A010Hd ddO N21l1 I ® J N I NtIVMM 3IV110AO10Hd 1l8NNO3SIO elV1OS Da ?J313W 13N A11111l dWb1S NMOHS SV 431V301 133NNO3SI4 HlIM S331:If10S DNIMO11Od (E)(8)Z6"s0L03N IVA021ddV(HV 3H1 Wald a 3 l 1 d d fl S SI D N I a 1 I f18 S I H 1 01 b 3 MO d W31SAS DIVI1OAO10Hd SI H92Jn0S GNOD8S zx.z 338nos 83nn0d iena9NIN21VMY NOlinVO I 1 (3noN2Hd) PI-IV/Alflh1n ._ Electrical Characteristics Mono-Crystalline Module(HiD-S__ RG(BK)) HYUNDAI SOLAR MODULE 310 315 320 2X2.. AHJ APPROVAL Nominal Output(Pmpp) W 310 315 320 STAMP RG Mono-Crystalline Type Open Circuit Voltage(Voc) V 40.3 40.5 40.6 Ili Dill II HiD-S31ORG(BK) HiD-S315RG(BK) HiD-S32ORG(BK) hili [HI Short Circuit Current(Isc) 9.94 9.99 10.04 Voltage at Pmax(Vmpp) III 33.1 33.4 33.7 BLACK Ili, Current at Pmax(Impp) 9.45 9.51 9.57 .111I I Cell Type 6.25",mono-crystalline silicon 11I1 'I I Maximum System Voltage 1,000 ..11I1UJ I Temperature Coefficient of Pmax -0.391 lili' ' ...,Ill' Temperature Coefficient of Voc -0.31 -**:**1::::: ; � Temperature Coefficient of Isc 0.031 CAPST N E 6 O 17 ei II 111111111 NI data at STC(Standard Test Conditions).Above data may be changed without prior notice S O L A R Cells All black Module More Power Assembled MIL! DESCRIPTION DATE REVISION Generation in USA with .1, . I I III INITIAL 8.JUL.2021 I In Low Light Hyundai Cell Ir1� , sndai Oej Mechanical Characteristics Installation Safety Guide �I! I III • * • •Only qualified personnel should install or Dimensions 1,007 mm(39")x 1,681 mm(66")x 33 mm(1.3") ( * * ) perform maintenance. - Weight 18.2 kg(40.11bs) •Be aware of dangerous high DC voltage. "9 Q g•Do not damage or scratch the rear surface ss ,) Solar Cells 60 cells in series(6 x 10 matrix)(Hyundai cell) Solar Specialist Sembled\c of the module. Amp. I Output Cables 4 mm2(12AWG)cables with polarized weatherproof connectors, •Do not handle or install modules when they TAYLOR DISCH MEI- -0- Ilex IEC certified(UL listed),Length 1.0 m(39.4") are wet. System Engineer , PERC Technology Anti-LID/PID t t t Mechanical Strength Junction Box IP65,weatherproof,IEC certified(UL listed) Nominal Operating 46°C±2 Cell Temperature TIM WACHTMAN PERC technologyprovides ultra-high Both LID(Light Induced Degradation)and Temperedglass and reinforced frame Bypass Diodes 3 bypass diodes to prevent power decrease by partial shade Operating Temperature -40-85°C 9 9 9 p p 9 P efficiency with better performance in low PID(Potential Induced Degradation)are design withstand rigorous weather Front Glass:Anti-reflection coated glass,3.2 mm(0.126") System Designer Construction Enca sulant:EVA I Back Sheet:Weatherproof r Maximum System Voltage DC 1,000 V irradiation.Maximizes installation capacity strictly eliminated to ensure higher actual conditions such as heavy snow and strong p p ooffilm Y 9 CASEY MILLER in limited space. yield during lifetime. wind. Frame Clear anodized aluminum alloy type 6063(Black color) Maximum Reverse Current 20A Customer Info 411 JENNIFER BOWMAN cn NH i 3809 37TH DR u2 Reliable Warranty „ Corrosion Resistant O0 UL/VDE Test Labs ANACORTES,WA 98221 HYUNDAI Mwww.A Module Diagram(unit:mm) I-V Curves PARCEL#.P80341 Global brand with powerful financial Various tests under harsh environmental Hyundai's R&D center is an accredited test strength provide reliable 25-year conditions such as ammonia and salt-mist laboratory of both UL and VDE. Mono Crystalline Current[Al Project Details Si Type-Front Side View 38.1(967) ► to warranty. passed. CO}_ s 4.16 KW tto4.329.65)t • 'T T 8 ROOFTOP PV T 4x SYSTEM 7.12 00.26(6.6) 5 (180.85) 5 TILT Hyundai's Warranty Provisions About Hyundai Energy Solutions - °00.35(9) ^ Inma.lmed=,,000wim' 3 -OperatinoCellTemp=S°C 18.43°/4 12 PITCH Established in 1972,Hyundai Heavy Industries Group is one of the most trusted names in the 2 -Operating Cell Temp=25°C 12 Year Product Warranty p -Operating Cell Temp=05°C 12 heavy industries sector and is a Fortune 500 company.As a global leader and innovator,Hyundai O I -Operating Cell Temp=65°C AZIMUTH eas On materials and workmanship Heavy Industries is committed to building a future growth engine by developing and investing o o s 10 15 re2 • 25 30 35 40 45 heavily in the field of renewable energy. „a, Voltage[V] 270° 25 •25-Year Performance Warranty 0 I Current[A] DC SYSTEM RATING 1•EIS •Initial year:97% As a core energy business entity of HHI,Hyundai Energy Solutions has strong pride in providing o 12 11i Cell temp. •Linear warranty after second year: high-quality PV products to more than 3,000 customers worldwide. e o -Iwd.l ad=,,000wtm= -25C 4.16 kW with 0.7%p annual degradation, 8 AC SYSTEM RATING -!mid.bract=800W/m' 80%is guaranteed up to 25 years 5- 4 -Incld.lnad=n00W/m' 5.0 kW -I Meld'kW k =aaowim' 2 ESTIMATED ANNUAL PRODUCTION • 00.35(9) -Incid.lead=200W/m' Certification 00 10 20 30 40 1144 Voltage(V1 4,400 kWh/Yr UL 1703-3rd Edition-Flat-Plate Photovoltaic Modules and Panels (290.5) Drawing COOS LISTED 1• • 1 39.4(1007) EQUIPMENT: A HYUNDAI 1.30(33) A HYUNDAI PV MODULE SPECIFICATION ENERGY SOLUTIONS ENERGY SOLUTIONS SHEETS Sheet /1 Sales&Marketing Printed Date:05/2020 www.hyundai-es.co.kr Printed Date:05/2020 -/ l Pnn reed on Fsc cemaed Sales@hyundai-es.co.kr FV' xo-rnendlyp,per. FscE...3 / Single Phase Inverter 2X2„ with HD-Wave Technology for North America A"JSOVAL AMP SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ Single Phase Inverter SE7600H-US / SE10000H-US / SE11400H-US With I-I D-Wave Technology < OUTPUT SE3000H-US SE3800H-US SESOOOH-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US m Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5 5000 65000 @ 208V000 @ 240V 7600 10000 11400 @ 240V 10000 @ 208V VA for North America Maximum AC Power Output 3800 @ 240V 6000 @ 240V 11400 @ 240V 3000 3300 @ 208V 5000 5000 @ 208V 7600 10000 10000 @ 208V VA —Atil____ SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ ✓ ✓ Vac CAPST°NE (211-240-264) AC Output Voltage Min.-Nom.-Max. ✓ Vac SOLAR SE7600H-US / SE10000H-US / SE11400H-US .'..I (183-208-229) - - ,i AC Frequency(Nominal) 59.3-60-60.511 Hz DESCRIPTION DATE REVISION _ Maximum Continuous Output X5 Current 12.5 16 21 25 32 42 47.5 A INITIAL 8.JUL.2021 YEAR Maximum Continuous Output O WARRANTY Current @208V - 16 24 48.5 A GFDI Threshold 1 A 0 ,3 Utility Monitoring,Islanding Protection, Country Configurable Thresholds Yes INPUT Solar Specialist Maximum DC Power©240V 4650 5900 7750 9300 11800 15500 17650 W o 40 Maximum DC Power @208V - 5100 - 7750 - - 15500 W TAYLOR DISCH o ® Transformer-less,Ungrounded Yes System Engineer Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc TIM WACHTMAN Maximum Input Current @240VI�I 8.5 10.5 13.5 16.5 20 27 30.5 Adc e solar, '[" , D..,,,,,, • e GolarDST. ._.HD..,,... ® System Designer Maximum Input Current @208V2 9 13.5 27 Adc S s • .J f! 1 Max.Input Short Circuit Current 45 Adc CASEY MILLER O O Reverse-Polarity Protection Yes Customer Info o 41110 O0— Ground-Fault Isolation Detection 600ku Sensitivity JENNIFER BOWMAN Maximum Inverter Efficiency 99 99.2 % 3809 37TH DR 99 @ 240V ANACORTES,WA 98221 CEC Weighted Efficiency 99 % 98.5©208V PARCEL#.P80341 O 0 O O Nighttime Power Consumption <2.5 W V' ADDITIONAL FEATURES Project Details Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) 4.16 KW Revenue Grade Data,ANSI C12.20 Optionall'I ROOFTOP PV Rapid Shutdown-NEC 2014 and SYSTEM Optimized installation with HD-Wave technology 2017690.12 Automatic Rapid Shutdown upon AC Grid Disconnect TILT STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 18.43° 4:12 PITCH / Specifically designed to work with power optimizers / UL1741 SA certified,for CPUC Rule 21 grid compliance Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) AZIMUTH Emissions FCC Part 15 Class B 2 7 0° / Record-breaking 99%weighted efficiency / Small, lightweight,and easy to install both INSTALLATION SPECIFICATIONS outdoors or indoors DC SYSTEM RATING AC Output Conduit Size/AWG Range 1"Maximum/14-6 AWG 1"Maximum/14-4 AWG / Quick and easy inverter commissioning directly from 4.16 kW DC Input Conduit Size/#of Strings/ 1"Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG a smartphone using the SolarEdge SetApp / Built-in module-level monitoring AWG Range AC SYSTEM RATING Dimensions with Safety Switch in/ 17.7 x 14 6 x 6.8/450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 mm / Fixed voltage inverter for longer strings / Optional:Faster installations with built-in 5.0 kW Weight with Safety Switch 22/10 251/11.4 26 2/119 38.8/17.6 lb/kg consumption metering(1%accuracy)and ESTIMATED ANNUAL PRODUCTION / Integrated arc fault protection and rapid shutdown production revenue grade metering(0.5%accuracy, Noise <zs <50 dBA for NEC 2014, NEC 2017 and NEC 2020 per article ANSI C12.20) Cooling Natural Convection 4,400 kWh/Yr 690.11 and 690.12 Operating Temperature Range -13 to+140/-25 to+60101(-40°F/-40"C option)oi °F/°C Drawing Protection Rating NEMA 4X(Inverter with Safety Switch) at For other regional settings please contact SolarEdge support EQUIPMENT: O A higher current source may be used;the inverter will limit its input current to the values stated INVERTER SPECIFICATION solar of Revenuer power grade de-r inverter P/Nrm ionxefer to hop NC2 °I For power de-rating Information refer to.OONN/www solaredge com/sites/defaulVfiles/se-temperature-Berating-note-na pdf SHEETS so I a red ge.co m In-40 version P/N:SExxxxH-USOOONNU4 ®SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All Ro H S Sheet other trademarks mentioned herein are trademarks of their respective owners.Date:03/2019A/01/ENG NAM.Subject to change without notice. E-4 / Power Optimizer -CI For North America 2°X2° Power O pti mizer P320 / P340 / P370 / P400 / P405 / P485 / P505 AHJ TAMP APPROVAL OP340 P370 For North America Optimizer model P320 (for high- (for higher- P400 P405 P485 P505 (typical module (for 60 cell power power (for 72& (for high- (for high- (for higher compatibility) modules) 60 cell 60 and 72- 96-cell voltage voltage current P320 / P340 / P370 / P400 / P405 / P485 / P505 modules) cell modules) modules) modules) modules) m modules) INPUT Rated Input DC Power) 320 340 370 400 405 485 505 W Absolute Maximum Input Voltage 48 60 80 12SI�I 832 Vdc _INIIiMalilliklambft—_ 2 C J Q (Voc at lowest temperature) MPPT Operating Range 8-48 11 8-60 8-80 10.1 12.5-105 12 5-83 Vdc CAPST O N E YEAR Maximum Short Circuit Current(OK) 14 Adc SOLAR WARRANNTY / Maximum DC Input Current 13.75 12.5 17.5 Adc MO// DESCRIPTION DATE REVISION Maximum Efficiency 99.5 % l!Fill 1 r Weighted Efficiency 98.8 98.6 % [F l Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) 11'y Maximum Output Current 15 Adc 11 Maximum Output Voltage 60 SS Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Solar Specialist / Safety Output Voltage per Power N Optimizer INITIAL 8.JUL.2021 +o� Vdc TAYLOR DISCH STANDARD COMPLIANCE System Engineer 1 EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 TIM WACHTMAN Material UL94 V-0,UV Resistant RoHS Yes System Designer INSTALLATION SPECIFICATIONS CASEY MILLER Maximum Allowed System Voltage 1000 Vdc Customer Info Compatible inverters All SolarEdge Single Phase and Three Phase inverters 129x153x33.5/ 129 x 162 x 59/ mm JENNIFER BOWMAN Dimensions(W x L x H) 129x153x27.5/5.1x6x1.1 5.1x6x1.3 129x159x49.5/5.1x6.3x1.9 5.1x6.4x2.3 /in 3809 37TH DR Weight(including cables) 630/1.4 750/1.7 845/1.9 1064/2.3 gr/lb ANACORTES,WA 98221 Input Connector MC41 Single or dual MC413j PARCEL#.P80341 p MC4tax^I Input Wire Length 0.16/0.52 ' m/ft Project Details Output Wire Type/Connector Double Insulated/MC4 4.16 KW Output Wire Length 0.9/2.95 1.2/3.9 1.2/3.9 1.2/3.9 12/3.9 m/ft ROOFTOP PV Operating Temperature Rangel51 -40-+85/-40-+185 °C/°F SYSTEM PV power optimization at the module-level Protection Rating IP68/NEMA6P TILT Relative Humidity 0-100 % it Rated power of the module at STC will not exceed the optimizer°Rated Input DC Power'.Modules with up to+5%power tolerance are allowed 1 8.43°/4:12 PITCH m NEC 2017 requires max input voltage be not more than 80V / Specifically designed to work with SolarEdge / Fast installation with a single bolt m For other connector types please contact SolarEdge AZIMUTH In For dual version for parallel connection of two modules use the P485 In the case of an odd number of PV modules in one string,installing one P485 dual version power optimizer inverters vi For ambient temperature above+85°C/+185°F power de-rating is applied Refer to Power Optimizers Temperature De-Rating Technical Note for more details. 270° / Next generation maintenance with module- DC SYSTEM RATING / Up to 25% more energy level monitoring PV System Design Using Single Phase Three Phase for Three Phase for 4.16 kW o1 Single phase / Superior efficiency(99.5%) / Meets NEC requirements for arc fault a SolarEdge Inverter,, HD Wave 208V grid 277/480V grid AC SYSTEM RATING P320,P340,P370, protection (AFCI) and Photovoltaic Rapid Minimum String Length P400 8 10 18 5.0 kW / Mitigates all types of module mismatch losses, Shutdown System (PVRSS) (Power Optimizers) P405,P485,P505 6 8 14 from manufacturing tolerance to partial Maximum String Length 25 25 sojel ESTIMATED ANNUAL PRODUCTION shading (Power Optimizers) 4,400kWh Yr / Module-level voltage shutdown for installer 5700(6000with and firefighter safety Maximum Power per String SE7600-US-5E11400- 5250 6000i) 1275000j W Drawing US) / Flexible system design for maximum space Parallel Strings of Different Lengths utilization or Orientations Yes EQUIPMENT: IG For detailed string sizing information refer to:http//www.solaredge com/sites/default/files/string_sizing_na.pdf DC/DC POWER OPTIMIZER nit is not allowed to mix P405/P485/P505 with P320/P340/P370/P400 in one string w SPECIFICATION SHEETS A string with more than 30 optimizers does not meet NEC rapid shutdown requirements;safety voltage will be above the 30V requirement I0 For 208V grid it is allowed to install up to 6,500W per string when the maximum power difference between each string is 1,000W I.I.For 277/480V grid:it is allowed to install up to 17,550W per string when the maximum power difference between each string is 2,000W Sheet solaredge.com solar • • -r T Al SolarEdge Technologies Ltd.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc. CC■,' Ro H S All other trademarks mentioned herein are trademarks of their respective owners.Date:12/2019/V02/ENG NAM.Subject to change without notice. Intertek E.5 2"X2" AHJ APPROVAL STAMP _...iiiiLimii.._ PART TABLE FLASH LOC :E" UNIRAC' FLASH LOC :E: UNIRAC4 P/N DESCRIPTION 004085M FLASHLOC COMP KIT MILL,20 PACK BETTER SOLAR STARTS HERE INSTALLATION GUIDE BETTER SOLAR STARTS HERE CAPST9NE 004085D FLASHLOC COMP KIT DARK,20 PACK FLASHLOC is the ultimate attachment for composition shingle and rolled comp roofs.The all-in-one mount installs '� .:-' r .7 PRE-INSTALL SOLAR 5/16"x 4"SS LAG BOLT fast—no kneeling on hot roofs to install flashing,no prying or cutting shingles,no pulling nails.Simply drive the Snap chalk lines for attachment rows.On shingle roofs,snap lines 1-3/4"below upslope edge DESCRIPTION DATE REVISION W/SS EPDM BONDED WASHER of shingle course.Locate rafters and mark attachment locations. lag bolt and inject sealant into the base.FLASHLOC's patented TRIPLE SEAL technology preserves the roof and a l,;5° INITIAL 8.JUL.2021 1 SS SERRATED T-BOLT iAt each location,drill a 1/32"pilot hole.Clean roof surface of dirt,debris,snow,and ice. _ protects the penetration with a permanent pressure seal.Kitted with lag bolts,sealant,and hardware for maximum SS SERRATED FLANGE NUT +� 01� Next,BACKFILL ALL PILOT HOLES WITH SEALANT. `«`I�� convenience.Don't just divert water,LOC it out! 1 �E— �� FLASHLOC BASE NOTE:Space mounts per racking system install specifications. �M.1 MILL OR DARK ��-.�& ����`� i auNiRac STEP 1:SECURE Solar Specialist Place FLASHLOC over pilot hole with lag on down-slope side.Align indicator marks on sides of 1rr_1 mount with chalk line.Pass included lag bolt and sealing washer through FLASHLOC into pilot TAYLOR DISCH VA" .1 TESTED TO TAS-100 hole.Drive lag bolt until mount is held firmly in place. System Engineer VVV WIND DRIVEN RAIN TEST YEAR AND 3L441 RAIN TEST `Js Y 1. e NOTE:The EPDM in the sealing washer will expand beyond the edge of the metal washer when 21/4 RUMproper torque is applied. TIM WACHTMAN WARRANTY WOW.% ill System Designer O 111111 STEP 2:SEAL CASEY MILLER Insert tip of UNIRAC provided sealant into port.Inject until sealant exits both vents. 3L�„ l Customer Info J,�UNiRAC 1lel, Continue array installation,attaching rails to mounts with provided T bolts. JENNIFER BOWMAN ®J`� /-1i'. 3809 37TH DR tml ' 6,� ' \ y ANACORTES,WA 9822 1 ■ PARCEL#.P80341 1 , Project Details NOTE:When FLASHLOC is installed over gap between shingle tabs or vertical joints, 3 fill gap/joint with sealant between mount and upslope edge of shingle course. 4.16 KW misimeli , } scar ROOFTOP PV 2 ��, USE ONLY UNIRAC APPROVED SEALANTS:Chemlink0uralink50,ChemlinkM-1,1eoce145o0,orceacelS-4 SYSTEM a,awaryew • R �. TILT PROTECT THE ROOF LOC OUT WATER HIGH-SPEED INSTALL V.\" Install a high-strength waterproof attachment With an outer shield II contour-conforming gasket Simply drive lag bolt and inject sealant into the port ll3 SEALANT I8.43°/4 12 PITCH without lifting,prying or damaging shingles. MI and pressurized sealant chamber Ei the Triple Seal to create a permanent pressure seal -,tt AZIMUTH • PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE technology delivers a 100%waterproof connection. Ir U N I RAC ALL DIMENSIONS ARE G 270° 1411 BROADWAY BLVD.NE DRAWING TYPE: PART DRAWING NOMINAL J DC SYSTEM RATING ALBUQUERQUE,NM 87102 USA DESCRIPTION: FLASHLOC COMP KIT PRODUCT PROTECTED BY LI— FASTER INSTALLATION. 2 5-YEAR WARRANTY. FASTER INSTALLATION. 2 5-YEAR WARRANTY. PHONE:505.242.6411 ONE OR MORE US PATENTS 4.16kW WWW.UNIRAC.COM .2REVISION DATE: 4/28/2020 LEGAL NOTICE , SHEET FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 AC SYSTEM RATING 5.0 kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr Drawing EQUIPMENT: RACKING SYSTEM, ROOF ATTACHMENT Sheet s— i 2"X2" AHJ APPROVAL STAMP _...... aiLhasias_ int` rt` k int` rt` k 13°°erry Court 7406 tot` rt` k 130 Derry Court CAPSTONE York,Pen130 Derry 1]406 York,Pennsylvania 1]406 SOLAR Total Quality.Assured. Total Quality.Assured. Telephone: 717-764-7700 Total Quality.Assured. Telephone: 717-764-7700 Facsimile: 717-764-4129 Facsimile: 717-764-4129 — — wvAvintertek.com/building www.intertek.com/building DESCRIPTION DATE REVISION TEST REPORT FOR UNIRAC,INC. TEST REPORT FOR UNIRAC,INC. Report No.:K1187.01-109-18 Report No.:K1187.01-109-18 INITIAL 8.JUL.2021 1 U N I RAC, I N C• Revision 1:09/24/19 Revision 1:09/24/19 = Date:09/24/19 Date:09/24/19 ■��//jrI■■y ■��///�■■ 1 Test Specimens#3 and#4 with M-1e sealant ■ _ ■IA■ _ ■ i—DARE 1411 BrUNIRACoadway 1411 Broadway Blvd.NE Test Procedure:The wind speed intervals were conducted as follows: Albuquerque,New Mexico 87102-1545 Interval No. Wind Speed(mph) Time(min) Water Spray TEST REPORT 1 35 15 Solar Specialist cTicl•)i 2 0 5 Off SCOPE 3 70 15 On TAYLOR DISCH Intertek Building&Construction(B&C)was contracted by Unirac,Inc.to perform TAS 100(A) 4 0 5 Off SCOPE OF WORK testing in accordance with Miami-Dade County requirements on their FLASHLOC,Roof Mounts. 5 90 15 On System Engineer TAS 100(A)TESTING ON FLASHLOC,ROOF MOUNTS Results obtained are tested values and were secured by using the designated test method(s). 6 0 5 Off Testing was conducted at the Intertek B&C test facility in York,Pennsylvania.This report does not 7 110 5 On TIM WACHTMAN REPORT NUMBER constitute certification of this product nor an opinion or endorsement by this laboratory. 8 0 5 Off K1187.01-109-18 Test Results: The TAS 100(A)test results are as follows: Allowed ws: System Designer TEST DATE(S) 09/09/19 35 mph o oz. N/A CASEY MILLER 70 mph 0 oz. N/A ISSUE DATE REVISED DATE Customer Info 09/24/19 09/24/19 90 mph _ 0 oz. N/A 110 mph 0oz. N/A JENNIFER BOWMAN RECORD RETENTION END DATE Total 0 oz. 13.6 oz. 3809 37TH DR 09/09/29 °°cice""'� Results:Pass ANACORTES,WA 9822 I MIAMI-DADECOUNTY NOTIFICATION NO. \...' ENu� '., PARCEL#.P80341 ATI 19048 ;IC)/ C)/'�o General Note: Each configuration was evaluated separately with no leakage at the mount f7• No.a3o35 — locations during or after the test. I roject Details LABORATORY CERTIFICATION NO. W FTATE of ••47. 4..I6 KW 18-0524.13 '3�tt`'..(O R IOP Cn>?:: PAGES181 For INTERTEK B&C: 64 S40/4`t060s ROOFTOP PV 18 COMPLETED BY: Roberti.Beatty 1'1: ,,.E Daniel C.Culbert,P.E. SYSTEM Technician— DOCUMENT CONTROL NUMBER TITLE: Product Testing Senior Project Engineer TILT ATI 00651(08/21/17) / 18.43°/4 12 PITCH RT-R-AMER-Test-2816 � /Y7 7' ©2017 INTERTEK • SIGNATURE: „ „w AZIMUTH DATE: 09/24/19 Oen=09/24/19 RIB:wnl 270' 2019.09.25 09:59:46-04'00' This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and Its Client. DC SYSTEM RATING Intertek•s responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this report. 4.16 kW Only the Client is authorized to permit copying or distribution of this report and then only In its entirety.Any use of the Intertek name or e of its marks for the sale or advertisement of the tested material,product or service must first rtby yed in writing by Intertek. AC SYSTEM RATING The observations and test results in this report are relevant°My to the sample(s)tested.This report by itself does not imply that the material,product,or service is or has ever been under an Intertek certification program. Version:08/21/17 Page 2 of 18 RT-R-AMER-Test-2816 Version:08/21/17 Page 6 of 18 RT-R-AMER-Test-2816 5.0 kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr Drawing EQUIPMENT: RACKING SYSTEM, ENGINEERING STAMP Sheet S.-.2 2"X2" PART#TABLE UNIVERSAL AF UNIVERSAL AF AHJ APPROVAL P/N DESCRIPTION END CLAMP MID CLAMP STAMP 302045M UNIVERSAL AF MID CLAMP- MILL T 302045D UNIVERSAL AF MID CLAMP- DRK O 1%" 0 1%" 1 I,�,� 302050M UNIVERSAL AF END CLAMP- MILL �_� 302050D UNIVERSAL AF END CLAMP- DRK _ C _ 1 I 13/ n 1�n k I 16 4 Inn '" CAPST9NE ICI SOLAR 30mm to I 30mm to 46mm II MODULE FRAME s: , MODULE FRAME / DESCRIPTION DATE REVISION I"` �l�Z�� INITIAL 8.JUL.2021 1 I I I I UNIVERSAL I 1 1 1 Solar Specialist MID CLAMP I 1 1 1 TAYLOR DISCH �f� I_---_I I_---_I System Engineer UNIVERSAL `48. END CLAMP TIM WACHTMAN = SO5 System Designer .. III CASEY MILLER Customer Info - JENNIFER BOWMAN \I/ \ 3809 37TH DR pl AN PARCEL 8 341S,WA 1 Project Details 4.16 KW c ROOFTOP PV SYSTEM TILT 18.43°/4 12 PITCH AZIMUTH 270° \ DC SYSTEM RATING 4.16kW AC SYSTEM RATING S.OkW �� PRODUCTDESCRIPTION:LINE: SOLARMOUNT DRAWING NOT TO SCALE' ESTIMATED ANNUAL PRODUCTION IP U N I RAC 1411 BROADWAY BLVD.NE ALL DIMENSIONS ARE 0 4,400 kWh/Yr DRAWING TYPE: PART &ASSEMBLY NOMINAL ea Drawing ALBUQUERQUE,NM 87102 USA UNIVERSAL AF PRODUCT PROTECTED PHONE:505.242.6411 CLAMPS BY"[ 2.c.0 1 [ONE OR MORE US PATENTS EQUIPMENT: WWW,UNIRAC,COM REVISION DATE: 9/28/2020 LEGAL NOTICE SHEET RACKING SYSTEM, CLAMPS Sheet S-3 2"XZ" AHJ APPROVAL BONDING SPLICE BAR %" BOLT LOCATION- STAMP 1 n Ir o 1 0 0 nri, 0 Ai F.,1546„,1 �- 4" —ID. CAPST9NE SOLAR DESCRIPTION DATE REVISION 2 9/16" r 0 INITIAL 8.JUL.2021 1 M ,---. ,..---.. W 101 1�1\ _I , Solar Specialist TAYLOR DISCH 5/16"-18 TYPE F THREAD 3/8" BOLT LOCATION---,,,,,,,` System Engineer CUTTING SCREWS INCLUDED TYPICAL SPLICE BAR DETAIL TIM WACHTMAN n H i System Designer 1�"� / 1 CASEY MILLER Customer Info PART#TABLE JENNIFER BOWMAN 3809 37TH DR P/N DESCRIPTION LENGTH ANACORTES,WA 98221 �- �� PARCEL#.P80341 - 1�I 101 320132M SM RAIL 132" MILL 132" �--" 310132C SM RAIL 132"CLR 132" Project Details 4.16 KW 320168M SM RAIL 168" MILL 168" ROOFTOP PV NOTE THAT ONLY 2 SCREWS ARE TYPICAL EXPANSION JOINT DETAIL USED AT AN EXPANSION JOINT. 310168C SM RAIL 168"CLR 168" SYSTEM THE SPLICE BAR DOES NOT BOND 320168D SM RAIL 168" DRK 168" TILT ACROSS AN EXPANSION JOINT. 18.43°/4 12 PITCH SEE INSTALLATION GUIDE FOR 320208M SM RAIL 208" MILL 208" PART#TABLE INSTRUCTION. AZIMUTH 310208C SM RAIL 208"CLR 208" 270° P/N DESCRIPTION 320240M SM RAIL 240" MILL 240" DC SYSTEM RATING 303019M BND SPLICE BAR PRO SERIES MILL 310240C SM RAIL 240"CLR 240" 4.16kW 303019D BND SPLICE BAR PRO SERIES DRK 310240D SM RAIL 240" DRK 240" AC SYSTEM RATING J ` J S.0KW ■■ PRODUCT LINE: SOLARMOUNT [DRAWING NOT TO SCALE , ■■ [PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE ESTIMATED ANNUAL PRODUCTION ■■■U N I RAC ALL DIMENSIONS ARE ■■■U N I RAC ALL DIMENSIONS ARE '� ■■ O ■■ O 4,400 kWh/Yr DRAWING TYPE: PART&ASSEMBLY NOMINAL Q DRAWING TYPE: PART DETAIL NOMINAL o- 1411 BROADWAY BLVD.NE 1411 BROADWAY BLVD.NE Drawing SPLICE ALBUQUERQUE,NM 87102 USA DESCRIPTION: BONDINGBA PRO SERIES PRODUCT PROTECTED BY E ALBUQUERQUE,NM 87102 USA DESCRIPTION: STANDARD RAIL PRODUCT PROTECTED BY Vf EQUIPMENT: PHONE: 505.242.6411 ONE OR MORE US PATENTS PHONE:505.242.6411 LONE OR MORE US PATENTS RACKING SYSTEM, RAIL WWW.UNIRAC,COM REVISION DATE: 8/23/2018 LEGAL NOTICE J SHEET J WWW.UNIRAC.COM REVISION DATE: 9/11/2017 LEGAL NOTICE SHEET Sheet S-4 S1 i s 2„X2 p7 AHJ APPROVAL STAMP structural structural ENGINEERS ENGINEERS April 28,2020 Unirac Components and Cladding Roof Zones: 1411 Broadway Blvd.NE The Components and Cladding Roof Zones shall be determined based on ASCE 7-05,ASCE 7-10&7-16 Component and Albuquerque,NM 87102 Cladding design. Attn.: Unirac-Engineering Department Notes: 1)U-builder Online tool analysis is only for Unirac SM SOLARMOUNT Rail Flush systems only and do not CAPSTkNE include roof capacity check. O 1 Re:Engineering Certification for the Unirac U-Builder 2.0 SOLARMOUNT Flush Rail 2)Risk Category II per ASCE 7-16. DESCRIPTION DATE REVISION 3)Topographic factor,kzt is 1.0. INITIAL 8.JUL.2021 1 PZSE, Inc.-Structural Engineers has reviewed the Unirac SOLARMOUNT rails,proprietary mounting system constructed 4)Array Edge Factor YE=1.5 from modular parts which is intended for rooftop installation of solar photovoltaic(PV)panels;and has reviewed the U 5)Average parapet height is 0.0 ft. builder Online tool.This U-Builder software includes analysis for the SOLARMOUNT LIGHT rail,SOLARMOUNT 6)Wind speeds are LRFD values. STANDARD rail,and SOLARMOUNT HEAVY DUTY rail with Standard and Pro Series hardware. All information,data and 7)Attachment spacing(s)apply to a seismic design category E or less. analysis contained within are based on,and comply with the following codes and typical specifications: Solar Specialist 1. Minimum Design Loads for Buildings and other Structures,ASCE/SEI 7-05,ASCE/SEI 7-10,ASCE/SEI 7-16 Design Responsibility: TAYLOR DISCH 2. 2006-2018 International Building Code,by International Code Council,Inc.w/Provisions from SEAOC PV-2 2017. The U-Builder design software is intended to be used under the responsible charge of a registered design professional System Engineer 3. 2006-2018 International Residential Code,by International Code Council,Inc.w/Provisions from SEAOC PV-2 where required by the authority having jurisdiction.In all cases,this U-builder software should be used under the 2017. direction of a design professional with sufficient structural engineering knowledge and experience to be able to: TIM WACHTMAN 4. AC428,Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic(PV)Panels,November • Evaluate whether the U-Builder Software is applicable to the project,and System Designer 1,2012 by ICC-ES. • Understand and determine the appropriate values for all input parameters of the U-Builder software. CASEY MILLER 5. 2015 Aluminum Design Manual,by The Aluminum Association,2015 Customer Info Following are typical specifications to meet the above code requirements: This letter certifies that the Unirac SM SOLARMOUNT Rails Flush,when installed according to the U-Builder engineering JENNIFER BOWMAN report and the manufacture specifications,is in compliance with the above codes and loading criteria. 3809 37TH DR Design Criteria: Ground Snow Load=0-100(psf) ANACORTES,WA 9822 1 PARCEL#.P80341 Basic Wind Speed=85-190(mph) This certification excludes evaluation of the following components: Project Details Roof Mean Height=0-60(ft) 1) The structure to support the loads imposed on the building by the array;including,but not limited to:strength Roof Pitch=0-45(degrees) and deflection of structural framing members,fastening and/or strength of roofing materials,and/or the effects 4.16 KW ROOFTOP PV Exposure Category=B,C&D of snow accumulation on the structure. SYSTEM Attachment Spacing: Per U-builder Engineering report. 2) The attachment of the SM SOLARMOUNT Rails to the existing structure. TILT 3) The capacity of the solar module frame to resist the loads. I Cantilever: Maximum cantilever length is L/3,where"L"is the span noted in the U-Builder online 8.43°/4 12 PITCH tool. This requires additional knowledge of the building and is outside the scope of the certification of this racking system. I AZIMUTH Clearance: 2"to 10"clear from top of roof to top of PV panel. 270° If you have any questions on the above,do not hesitate to call. ��1� K. Z4 C,y DC SYSTEM RATING Tolerance(s): 1.0"tolerance for any specified dimension in this report is allowed for installation. j roe WAsif F� 4.16 kW c, Installation Orientation: See SOLARMOUNT Rail Flush Installation Guide. Prepared by: �' ` G AC SYSTEM RATING PZSE,Inc.—Structural Engineers Landscape-PV Panel long dimension is parallel to ridge/eave line of roof and the PV 5.0 kW Roseville,CA panel is mounted on the long side. o ,�z o • Fc;s7Ev ESTIMATED ANNUAL PRODUCTION Portrait-PV Panel short dimension is parallel to ridge/eave line of roof and the PV panel <`''sc, p YN�'` is mounted on the short side. 4,40o kWh/Yr Drawing EXPIRES OS'= ">':_ I EQUIPMENT: 1478 Stone Point Drive,Suite 190, Roseville,CA 95661 1478 Stone Point Drive,Suite 190, Roseville,CA 95661 RACKING SYSTEM, ENGINEERING STAMP 916.961.3960 916.961.3965 www.pzse.com 1of2 916.961.3960 916.961.3965 www.pzse.com 2 of 2 Sheet S-5 2"X2" ENGINEERING REPORT Roof Area 1/Roof Area 1 -Array 1 AHJ APPROVAL STAMP Portrait Modules-Rails Running Across Slope Plan review Inspection SOLARMOUNT STANDARD RAIL ZONE 1 ZONE 2 ZONE 3 MAXIMUM POINT LOADS[LBS] ZONE 1 ZONE 2 ZONE 3 Distributed Dead Load 2.69 psf PRODUCT SOLARMOUNT FLUSH SPANS[IN] Up -96.8 -193.6 -303.6 MODULE MANUFACTURER DESIGN SPAN 48 48 48 Hyundai Down 207.9 207.9 207.9 Average Roof Point Dead Load 22.32 lbs MODEL 13-HiD-S32ORG(BK) Max Cantilever 16 16 16 Downslope 68.2 68.2 68.2 Max Span 108 108 91 CAPST°NE MODULE WATTS 320 watts TOTAL NUMBER OF MODULES 13 Lateral 19.8 19.8 19.8 MODULE LENGTH 66.00" SOLAR DESIGN PRESSURES[PSF] ZONE 1 ZONE 2 ZONE 3 Tributary Area[ft2] 11.0 11.0 11.0 TOTAL KW 4.16 KW MODULE WIDTH 39.00" DESCRIPTION DATE REVISION TOTAL AREAft2 Up -8.8 -17.6 -27.6 ROOF PITCH: 23° INITIAL B.JUL.2021 -232 MODULE THICKNESS 1.30" Down 18.9 18.9 18.9 Loads Used for Design MODULE WEIGHT 40.10 lbs Downslope 6.2 6.2 6.2 EXPANSION JOINTS Every 40' BUILDING CODE ASCE 7-10 Lateral 1.8 1.8 1.8 Solar Specialist RAILS DIRECTION EW TAYLOR BASIC WIND SPEED 110.00 mph DISCH BUILDING HEIGHT 30.00 ft System Engineer GROUND SNOW LOAD 25.00 psf ROOF TYPE Shingle TIM WACHTMAN SEISMIC(SS) 1.08 RAFTER SPACING 24.00" System Designer ELEVATION 482.00 ft TOTAL WEIGHT 625.04 lbs CASEY MILLER WIND EXPOSURE B Customer Info JENNIFER BOWMAN 3809 37TH Loads Determined by Zip 98221 DR ANACORTES,WA 9822 1 PARCEL#.P80341 CITY,STATE Anacortes,WA Project Details BASIC WIND SPEED 110.00 mph 4.16 KW ROOFTOP PV GROUND SNOW LOAD 0.00 psf SYSTEM TILT 18.43°/4 12 PITCH AZIMUTH 270° DC SYSTEM RATING 4.16 kW AC SYSTEM RATING 5.0 kW ESTIMATED ANNUAL PRODUCTION 4,400 kWh/Yr Drawing EQUIPMENT: RACKING SYSTEM, SITE SPECIFIC ENGINEERING Sheet S-6 2"X2" AHJ APPROVAL DETAILED PARTS DESCRIPTION Qn STAMP Rail 310168D SM RAIL 168"DRK 8 Structural aluminum extrusion containing slots that accept module and roof attachment hardware,electrical bonding accessories,and splice bars. .0 0 Splice 303019D BND SPLICE BAR PRO SERIES DRK 2 CAPSTONE Dark anodized aluminum extrusion for joining adjacent lengths of rail to one another. SOLAR Includes pre-assembled bolts.Uses 1/2"socket for 1-tool system install. DESCRIPTION DATE REVISION INITIAL 8.JUL.2021 1 lr Mid Clamp 302045D UNIVERSAL AF SERIES MID CLAMP DARK 20 Universal Aesthetic Fastener(Mid),Universal for modules between 30-46mm and features twist and lock installation,1 tool install,UL2703 integrated bonding,and low profile hardware and 1/2 module gap for optimal aesthetics.Made from Aluminum and Stainless Steel hardware. Solar Specialist TAYLOR DISCH End Clamp 302050D UNIVERSAL AF SERIES END CLAMP DARK 12 System Engineer Universal Aesthetic Fastener(End),Universal for modules between 30-46mm without the TIM WACHTMAN use of spacers or extra parts,Features twist and lock installation,1 tool install,UL2703 /P> integrated bonding,and low profile hardware for optimal aesthetics.Clamps can be placed System Designer anywhere on the rail and rail can be cut flush with the clamp for optimal aesthetics.Made from Aluminum and Stainless Steel hardware,Caps are PC/ASA. CASEY MILLER Customer Info Microinverter Mounting 008013S MICRO MNT BND T-BOLT 1/4in x 3/4in SS 13 JENNIFER BOWMAN 3809 37TH DR Attaches micro-inverter flange to beam using 3/4"x 1/4"bonding T-Bolt. ANACORTES,WA 98221 PARCEL#.P80341 Project Details 4.16 KW Grounding Lug(Weeb) 008002S GROUND WEEBLUG#1 3 ROOFTOP PV SYSTEM For electrical bonding of PV modules and rails.Accepts one 14AWG to 6AWG or two 12 AWG TILT to 10 AWG copper wires.Tin plated copper body,1/4"stainless steel fasteners. 18.437 4 12 PITCH AZIMUTH 270° 111/ Flashing 004085D FLASHLOC COMP KIT DRK 26 DC SYSTEM RATING 4.16 kW FLASHLOC is the ultimate attachment for composition shingle and rolled comp roofs.The all-in-one mount installs fast and looks great with dark anodized finish.Simply drive the lag bolt and inject sealant into the base.FLASHLOC's patented TRIPLE SEAL technology AC SYSTEM RATING preserves the roof and protects the penetration with a permanent pressure seal.Kitted with lag bolts,sealant,and hardware for maximum convenience. 5.0 kW ESTIMATED ANNUAL PRODUCTION 4.0, Conduit Mount 00802CM E-BOSS CONDUIT MOUNT COMP KIT 5 4,400 kWh/Yr aO Attach conduit mount directly to deck,using an included flashing and hardware or mounted Drawing 1/ to a rail or L-Foot using T-bolt.Accomodates both 1"and 3/4"conduit. EQUIPMENT: RACKING SYSTEM, BILL OF MATERIALS Sheet S- 7