HomeMy WebLinkAboutPermit File 1301 Portalis Court O 44
'- '431111C111111"P.°'
VP CO
/oink- veil;
CERTIFICATE OF OCCUPANCY
This is to certify that the below listed building or structure
has been inspected and occupancy is hereby authorized:
Description: New Single Family Residence
Location: 1301 Portalis Court
Owner: 496404 Washington Inc.
Constructed by: 496404 Washington Inc.
Building Permit#: BLD-2010-0444 -
Date issued: December 20, 2011
Occupancy Group: R-3
Use Zone: CM-PUD
Dated: October 5, 2012
Authorizing Official: (��� L �����
erY 3 Cityof Anacortes Permit#: BLD-2010-0444
904 6th Street Issue date: 12/20/2011
P.O.Box 547
WA 98221-0547 Expire date: 06/17/2013 try.: Anacortes,
'''- ',, 'Cris (360) 293-1901
Job Address: 1301 PORTALIS CT Permit Type: Single Family Residence Permit
ANACORTES WA 98221-4049 Project:
APN: P122175
Remarks: New Single family residence
Owner: 496404 WASHINGTON INC Contractor: 496404 WASHINGTON INC
Address: 4819 PORTALIS WAY Address:
ANACORTES WA 98221-4031
Phone: Phone:
License#:
General Information: Fees:
Basement Square Footage 750 Mechanical Permit Fees 107.40
1st Floor Square Footage 1265 Plumbing Permit Fee 118.00
Garage Square Footage 440 State Building Code Fee 4.50
# Forced Air Furnace<=1,000 1 Sewer Inspection Fee 50.00
#of Bathtubs 2 Storm Drain GFC-Residential 1,140.00
#of Clothes Dryers 1 Sewer GFC-Residential 7,096.00
#of Clothes Washers 1 Park Impact Fee 615.00
#of Dishwashers 1 Traffic Impact Fee 900.00
#of Gas Fireplace 1 Total Calculated: 10,030.90
#of Gas Piping 1 Deposits/Receipts: 0.00
#of Gas Water Heaters 1
#of Water Piping 1 Total Due: 10,030.90
#of Hose Bibbs 2
#of Kitchen Sinks 1
#of Lavatories 2
#of Range Hoods 1
#of Showers 2
#of Ventilation Fans 3 -5 ti
#of Water Closets 2 .. cj
a- C)
� I
fi
w Cr
CD 'o
CO
-A —
C NI
0
fiJ
Air {7
C• ,3
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR lb 2
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. ; , -
HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. AL =
PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN O r as
NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER
STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. 47)
SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY
PARTNERS INSULATION
A BDI COMPANY,INC.
�� New Construction•Re-Insulation•Insulation Removal•Commercial&Residential
PO Box 3275,Arlington,WA 98223
OFFICE(360)435-9945 FAX(360)360-435-9947
www.bdill9SULATION.com
License#PARTNIB906KG
INSTALLED INSULATION CERTIFICATE
We certify that the following residence has been insulated with the following materials:
CEILING BATTS VALUE R - 38
EXTERIOR WALLS VALUE R - 21
BASEMENT EXTERIOR WALLS VALUE R - 15
FLOOR VALUE R - 30
CEILING BLOW VALUE R - 49
Address: 1301 PORTALIS RD,ANACORTES Certify by: ttarea Tr,/r
Lot: #20
Date Installed: 4/19/2012 Title: Office Manager
" . .
•
f•
_ ,
Z - Public Orks`-
• Engineering andDevelopment Services
Residential Inspection
Address: o (z)@ �.L. 0 i Date: 9 i` _ -
Owner: Zit Tian_ tux. - .
.. Contractor:
Inspected by: . V
- 1. Water Me, • r Box •
Se and level to finished grade or backside of sidewalk elevation.
- Lid box undamaged.
-meter and customer shutoff installed.
No debris. -
R—essible—no landscape obstruction_.
Driv ay installation has drive-over box and lid.
us .,er gate valve intact_ V V V
o leaks at connections.
- 2. Curb and utter -
o cracks, damage, graffiti,footprints, finishing blemishes, or other objectionable
marks_ -
if road frontage improvements:. V V
❑ Expansion joints every 15 feet and at driveways.
❑ Concrete has broom finish_
- . -No low spot at curb line, especially at driveway cut. Maximum grade change in
20 feet is %inch. .
3 Sidewalk V V
No cks,damage, graffiti, footprints, finishing blemishes, or other objectionable V
arks.
ADA compliant— 1 percent slope to curb. .
- If road frontage improvements: . -
❑ . Expansion joints every 15 feet and at driveways_ V
❑ . Concrete has broom finish
4. Drivew App ches
N racks,damage,graffiti,footprints,finishing blemishes,or other objectionable
arks_
I ADA compliant_
..
. . . .
. - .
. „
. . • .
. . . . .
- -
.• - -
" . .
•
- '- -.
_ .
) - .. . .- A 5; Streets
• . . . • „.
. _ • • .
• I . El No crackS, .blemishes. _ • _ . .
.
.
. I If road or alley improvements: " - .
. . . -
- - - " El - Received proctor and sieve analysis of ballast, crushed rock, and asphalt.
r---1 •Received passing materials testing reports for sub-grade, ballast, crushed -
.
- ' ' rock,and asphalt. . : . .
. .
. • i E Received tonnage tickets consistent with required thickness per approved.
- - . L I plans. .. _--•
- . -
•6. Sanitary Sewer
. .
„ r+-1-nspection card signed off and/or verified in Building Department database.:
. .
1-4." As-built record filed in the address file. . .
- V , W'' .crew cap(s).instalfed on clean-out(s).. V V . . . V
.
R '61ean7out(s)set at finished grade . - , .
. .
- 7. Storm_ rainage . V .- nspection card signed off and/or verified in Building Department database.
WAS-built record filed in address file.
iti----N'ot blocked or diverted to adjacent parcel.
8. Public.Utilities Out of Traveled Way
} , Ei Concrete collars around-City Utilities. •
El Final grading ok. : .
Li Restored to prior condition or better. - •
9. Landscape V V
,
i . • 0 „Bonded for completion at later date. -
. • VerijØ against approved landscape plan: - - V • -
Installation.
_
- Ericpe and quantity of plants. . .
• .
- - R"l'od or seed in place. V ' V - - .
-
r --g.- galot barrier(receipt filed). - - .
.•
' - 10.Erosion Control Measures .
-
F-Agi.71,Ps reMoved. . . _
.
FU45Iemoved. Site,clean. V V -
..
- Permanent vegetation established. - .
. -
. .
- ..
. -
- - •
: "
. _
St r'-`-t j ' S e-4,41PeAr ft 0'Pril
, \t> -4-' /1.,,'6'" M YO,,a4(1 cv`Tekv-I
. t (71(w' . C digkteci coo S ki .o ?0 -4 is, 1... t c
Qv-
$
i '3 0 ( p A ( t S Ca LA-
q , _
-. ,
i 1 t...1
..,...--- -
----- ----- , .-7-7- .
1 .
,1 . •
_ • T
..„... .... _.,_
11 ,
1 ,q
) :
il
TI
1111
0 •--4-4k1)-
,
, t
OA ' al. , .
— :
ri
,J t
,.
. ,J
J ! ,
fer-
-
i COtartrei)
:1 l'
4 j t'
r t
1 j ,
•
t --,
04'`''''--- -- - t i ---•-••-,........„.„.„...,,„,,
- -- -. - ---
t t
. ,
t J
-------,- ----- --,—,--- ------ ,m— —
t j
— --, ,--- -— , - --- ,- —
j t
-. •-4±-- — -- ------- - - _-_ -4
—-- --
-,.
Page 1 of 1
Ingalls, Paul
From: Ingalls, Paul
Sent: Monday, November 22, 2010 10:08 AM
To: Allan Schroeder
Subject: 1301 Portalis Court
Al,
There are several details on the plans submitted for the new home at 1301 Portalis court that are not consistent.
The original architectural plans show a main floor that is basically level with the garage slab with no
corresponding wood floor connection to foundation detail.
The original engineering plan (8/17/10) and the revised (11/10/10) engineering plan shows the main floor
supported on top of the retaining wall foundation, which would make a stair between house and garage
necessary.
The original architectural plans show a lower floor constructed as a slab on grade.
The revised engineering shows a wood framed lower floor supported on a short pony wall with no connection to
the foundation detailed and no pony wall bracing (both will be required).
Please provide a plan set with consistent details that clearly indicate what is proposed, so that I can complete the
plan review.
Also, please submit the new site plan showing the building and deck meeting setback requirements.
Paul Ingalls
Building Inspector
City of Anacortes
360-293-1901
11/22/2010
_ - `O . Cityof Anacortes Permit#: BLD-2010-0444
904 6th Street Issue date: 12/20/2011
P.O.Box 547 Expire date: 06/17/2013
` ' I Anacortes, WA 98221-0547
'`-'t�r 4r a (360) 293-1901
0011:Job Address: 1301 PORTALIS CT Permit Type: Single Family Residence Permit
ANACORTES WA 98221-4049 Project:
APN: P122175
Remarks: New Single family residence
Owner: 496404 WASHINGTON INC Contractor: 496404 WASHINGTON INC
Address: 4819 PORTALIS WAY Address:
ANACORTES WA 98221-4031
Phone: Phone:
License#:
General Information: Fees:
Basement Square Footage 1415 Building Permit Fee 458.00
1st Floor Square Footage 1450 Mechanical Permit Fees 107.40
Garage Square Footage 495 Plumbing Permit Fee 118.00
Deck Square Footage 110 State Building Code Fee 4.50
# Forced Air Furnace<=1,000 1 Sewer Inspection Fee 50.00
#of Bathtubs 2 Storm Drain GFC-Residential 1,244.00
#of Clothes Dryers 1 Sewer GFC-Residential 7,096.00
#of Clothes Washers 1 Park Impact Fee 615.00
#of Dishwashers 1 Traffic Impact Fee 900.00
#of Gas Fireplace 1 Total Calculated: 10,592.90
#of Gas Piping 1 Deposits/Receipts: 10,030.9_0--
#of Gas Water Heaters 1
#of Water Piping 1 Total Due: ( 562.00 !
#of Hose Bibbs 2 —`
#of Kitchen Sinks 1 F,r, 3 e ,,,•& d cli e /o r, re Iv/e f-,--
#of Lavatories 2 �� /��, / ��� /� 'r
#of Range Hoods 1 �` �� ° ® -r, I_.
#of Showers 2 10 f 1'z�v E-6 a ?e4 4 � ,- ''g e `'
#of Ventilation Fans 3 a=:• a
#of Water Closets 2
'T1 1
0
n Cun
0 -_4
CO
Or M-..
to -
a... r.5
THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR 1i
CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED.r1I h"
HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL
PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR
NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER
STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION.
SIGNATU OF OWNER OR AUTHORIZED AGENT ISS D BY
Ingalls, Paul
From: Ingalls, Paul
Sent: Monday, November 08, 2010 8:22 AM
To: 'Mathew Lunde'
Cc: Allan Schroeder
Subject: RE: 1301 Portalis Court
Mathew,
We could, but some information is lacking in the detail:
There is no sill plate shown on the ledge block out, so how are the joists attached?
There are no measurements shown for joist bearing area, clearance to concrete, size &
type of joists.
We don't see this method used much, since there are much easier ways to do it.
The plan for 1301 Portalis Court is engineered for lateral loads; the engineer should
specify (or at least approve) the joist attachment method.
Paul Ingalls
Building Inspector
City of Anacortes
Original Message
From: Mathew Lunde [mailto:matt@lunde.ca]
Sent: Thursday, November 04, 2010 10:28 AM
To: Ingalls, Paul
Cc: Allan Schroeder
Subject: 1301 Portalis Court
Hi Paul, will the City of Anacortes accept this type of detail as an alternative to
providing joist hangers off the foundation wall?
Matt Lunde
Lunde Architect Ltd. / 925R Design Inc.
www.lunde.ca / www. 925rdesign.com
matt@lunde.ca
p.250.503.3000
f.250.503.3053
c.250.307. 6818
1
1
Anacortes Planning&Community Development Dept.
010,s+ Permit Center
P O Box 547,Anacortes,WA 98221-0547 PH(360)293-1901
*$ k-ro� Ryan Larsen,Director-Don Measamer,Building Official FAX(360)293-1938
4000-
November 1, 2010
Allan Schroeder
Portalis LLC
4819 Portalis Way
Anacortes, WA 98221
RE: Plan review notes for the proposed new residence at 1301 Portalis Court
Dear Allan,
Please address the following issues:
1. The detail on Sheet A7 and in the engineers plan shows the main floor system
supported on top of the east basement retaining wall. The East& West
elevations on sheet A5 and section detail #2 on A6 show a flush hung floor
system. Which is it? If it is hung, provide the engineers detail on the connection.
2. The upper story deck extends into the rear 20 foot setback area. This does not
comply with the conditions of the plat approval and the setback provisions of
the Anacortes Zoning Code.
Thank you,
Paul Ingalls
Building Inspector
City of Anacortes
360-293-1901