HomeMy WebLinkAboutPermit File BLD-2021-0264 5117 Maritime Court (2) PHOTOVOLTAIC ROOF MOUNT SYSTEM coydEEK 18 MODULES - SYSTEM SIZE STC (5.58 kW DC / 5.4 kW AC) 00_HO 5117 MARITIME CT, ANACORTES, WA 98221 , USA (48.49717, -122.67497) 00HL000 SYSTEM SUMMARY STC DC/AC SAFETY PLANS LOCATION OF NEAREST URGENT CARE FACILITY SHEET INDEX GREEN THINK ENERGY LLC NOTES: NAME: PV-1 SITE PLAN&SAFETY PLAN 50 HARRISON STREET, PV-2 ROOF PLAN WITH MODULES SUITE 202B (5.58 kW DC / 5.4 kW AC) • INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME. ADDRESS: HOBOKEN,NJ 07030 • INSTALLERS SHALL UPDATE NAME,ADDRESS AND PHONE NUMBER OF PV-3 ATTACHMENT DETAIL • 1 x STRING OF 3 CONNECTED IN PARALLEL NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE PHONE NUMBER: PV-4 SINGLE LINE DIAGRAM www.GreenThinkEnergy.com STARTING WORK. PV-5 WIRING CALCULATION CONTRACTOR • 2x STRINGS OF 1 CONNECTED IN PARALLEL PV-6 PLACARDS PV-7+ EQUIPMENT SPECIFICATION NAME:N/A - (18) Suntech STP310S-20 Wfb MODULES NOTES :AC DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER. ADDRESS:N/A - (4) Hoymiles HM-1200N MICROINVERTERS PHONE#:N/A - (1) Hoymiles HM-600N MICROINVERTERS LICENSE#:N/A STC DC: (18) 310 = 5.58 kW REVISIONS STC AC: (4) 1200 + (1) 600 = 5.4 kW PROJECT ID: N/A DESCRIPTION DATE REV MARITIME CT AHJ: ANACORTES REDLINE Jo610412021 A REDLINE 06/08/2021 B GOVERNING CODES ;; ARRAY LOCATION 2015 WASHINGTON STATE ENERGY CODES n7V-A I - F'� 2015 INTERNATIONAL BUILDING CODE ,,� PROPERTY LINE -- --- "` 4, ^ -7. SIGNATURE&SEAL 2015 INTERNATIONAL EXISTING BUILDING CODE z ! 41� To i. 2015 INTERNATIONAL FIRE CODE j �� 1 2015 INTERNATIONAL RESIDENTIAL CODELii ` 2015 UNIFORM PLUMBING CODE p T. I .� * +' ���� Ili 0; , � 111`I� • PROJECT NAME I w nN/ ,1 Q GENERAL NOTES: o i - + • ALL PANELS,SWITCHES,ETC.SHALL HAVE SUFFICIENT GUTTER -- I j J • ( H SPACE AND LUGS IN COMPLIANCE TO UL REQUIREMENTS TO I ACCOMMODATE CONDUCTORS SHOWN. - • THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL 2 HOUSE PHOTO Q W co FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. Z C • ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT I• . SCALE: NTS 0 Q INCLUDING THOSE THAT ARE EXPOSED TO OUTSIDE I ENVIRONMENT SHALL BE WEATHERPROOF AND SHALL BE ' MMIMEMM LISTED BY"UL"FOR THE TYPE OF APPLICATION AND"UL"LABEL I ,D_ SHALL APPEAR ON ALL ELECTRICAL EQUIPMENT. 22-7" UJ • WIRING METHOD SHALL BE EMT ABOVE GROUND MOUNTED IN I O CONCEALED SPACES(UNLESS APPROVED OTHERWISE)AND SCHEDULE-40 PVC FOR BELOW GROUND INSTALLATION -- -- -- -- -- -- -- -- -- -- -- -- -- -- - D UNLESS NOTED OTHERWISE. 75'_8' PROPERTY LINE Q • AN OSHA APPROVED LADDER PROVIDING ACCESS TO ALL PROJECT SITE O 1: PORTIONS OF THE ARRAY SHALL BE SECURED IN PRIOR TO /// W 0 REQUESTING INSPECTION. • IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A 0z SUPPLEMENTAL GROUNDING ELECTRODE CONDUCTOR IF ,•r I �l NECESSARY. ''�L I— M S P MAIN SERVICE PANEL AC AC DISCONNECT INV (0)INVERTER SUB EE EXISTING ROOF ATTACHMENT ---------- PROPERTY LINE V- Arac SUB-PANEL r cle SHEET NAME EQUIPMENT EXISTING (200A) UNFUSED N/A N/A N/A m . Ail LOAD CENTER UM UTILITY METER ACF AC DISCONNECT LC (COMBINER PANEL) DCD DC DISCONNECT • OPTIMIZER — // —DIMENSIONS FENCE m 5117 MSrI f I I7dE SITE PLAN & EXISTING FUSED NEW _ NEW N/A 7 SAFETY PLAN L CI, Af3acorles, WA,.- PM PRODUCTIONIB JUNCTION METERBOX S M DCC METER CC DC COMBINER MICRO-INVERTER PV MODULE GATE N/A NEW N/A N/A SHEET SIZE BAT BATTERY AT AUTO TRANSFORMER BLp BACKUP LOAD PANEL ' p A ANSI B 11" X 17" N/A NIA N/A SITE PLAN & SAFETY PLAN 3 VICISCALENITYS MAP SHEET NUMBER SCALE: 1/32" = 1' PV 1 MODULE AREA&WEIGHT CALCULATIONS NOTES :AC DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER. oeyiEKPANEL TYPES(COUNT,AREA,WEIGHT): •(18x)Suntech STP31OS-20 Wfb(65"x 39.1",40.3 LBS) ATTACHMENT COUNT:61 MA�ITI IV E CT IH_HE MOUNTING SYSTEM WEIGHT/MODULE:1.5 LBS TOTAL ROOF AREA:3660 SF ( �n�u^\ul n�����7 TOTAL ARRAY AREA:(18)65.0"x 39.1"=317.69 SF (E) E ISO N T YARD U�J \�V/ TOTAL ARRAY WEIGHT:(18)40.3+(18)1.5=752.4 LBS WEIGHT AT EACH CONNECTION:752.4 LBS/61 =12.33 LBS GREEN THINK ENERGY LLC 50 HARRISON STREET, DISTRIBUTED LOAD:752.4 LBS/317.69 SF=2.37 PSF �1-6 �9 SUITE 202B ROOF AREA COVERED BY ARRAY:317.69 SF/3660 SF=8.7% // 13'-3" HOBSUITEOKEN,NJ 07030 BILL OF MATERIALS ,y \ �'__ ' www.GreenThinkEnergy.com SOLAR PV MODULES 18 Suntech STP310S-20 Wfb 4 \ r CONTRACTOR MICRO INVERTERS 04 Hoymiles HM-1200N to\ -———I�- m NAME:N/A MICRO INVERTERS 01 Hoymiles HM-600N -0-+-0-041-0- ADDRESS:N/A LOAD CENTER 01 AC COMBINER PANEL(MIN RATING 25A) -G+-1� ��_A PHONE#:N/A - PV VISIBLE LOCKABLE •I -1 �I �U LICENSE#:N/A _ • LABELED DISCONNECT -Fe �• -1-04 -U REVISIONS AC DISCONNECT 01 I�I .�11 - (60A FUSED 1PH 240VAC) ——I i• Y DESCRIPTION DATE REV If LL ATTACHMENTS 61 IronRidge-XR FlashFoot2 _ — REDLINE 06/04/2021 A RAIL IronRidge-XR10 � ~ REDLINE 06/08/2021 B l>. —— •0��• afY SIGNATURE&SEAL V 1'-6' / 49'-7" /—10'-11"—/--/ \\\\\\\\\\\\MM\\MMO\\\\,"`111:'' ,'-L \\\\\\\\\\\\\\\\IM\\\\OW - I` I • 1 1 1 I I I 1 1 I I I I I. Q I I I 1 En o I I I I *1 I I I I I t _L' __L, PROJECT NAME 1 1 1 1 1 i 11 , i1 i ROOF#1 1 t D cn II 1 T i I II N D IIIIII I H H � U N l I Q CN wrn I U = < < Q : 2 aw � O z I a ROOF DESCRIPTION MAIN SERVICE PANEL AC DISCONNECTINVERTER SUB-PANEL EXISTING ROOF ATTACHMENT -----------RAFTERSI MSP AC INV (0) SUB EE _ MODULE ARRAY TRUSSES TRUSSES SPACING EXISTING (200A) UNFUSED N/A N/A N/A EQUIPMENT (— ROOF COUNT TILT AZIMUTH IT1SIZE (ATTACHMENT SPACING) LOAD CENTER C) SHEET NAME UTILITY METER AC DISCONNECT (COMBINER PANEL) DC DISCONNECT • OPTIMIZER —DIMENSIONS ROOF RAILS u J #1 06 20° 180° 2"X4" 24"OC(48") UM �ACF FUSED NEW LC NEW DCD N/A - // M ROOF PLAN WITH EXISTING #2 12 20° 90° 2"X4" 24"OC(48") MODULES pm PRODUCTION METER J B JUNCTION BOW SM SOLARED NEAMETER DCC DC COMBINNER le MICRO-INVERTERPV MODULE f///FIRE SETBACK 0 N/A SHEET SIZE BAT BATTERY AT AUTO TRANSFORMER Bhp BACKUP LOAD PANEL Ariv ANSI B N/A N/A N/A11" X 17" I ROOF PLAN WITH MODULESSHEET NUMBER SCALE: 1/16" = 1' PV-2 PV MODULE 1H-HE - 1 FERW SEE (2/PV-3) FOR ENLARGED VIEW GREEN THINK ENERGY LLC 50 HARRISON STREET, SUITE 202B HOBOKEN,NJ 07030 www.GreenThinkEnergy.com - (E) SINGLE LAYER OF CONTRACTOR COMPOSITE SHINGLE NAME:N/A ADDRESS:N/A O • PHONE#:N/A LICENSE#:N/A TRUSSES REVISIONS �' MF DESCRIPTION DATE REV REDLINE 06/04/2021 A REDLINE 06/08/2021 B SIGNATURE&SEAL 1 ATTACHMENT DETAIL SCALE: NTS PROJECT NAME I: Q PV MODULES I IRONRIDGE INTEGRATED H N GROUNDING & END/MID 11 CLAMP Q W IRONRIDGE XR10 RAIL 0 j (E) SINGLE LAYER OF 2 W COMPOSITE SHINGLE (n 1..ila.,,,,004 Q Ct -1111111111111111111111111111111111111111111 0 2 7) 8 ALUMN. "L" BRACKET = Q • W/3/8" SS BOLT & NUT IRONRIDGE FLASH111111 - FLASHING SHEET NAME FOOT2 ATTACHMENTS -- - .440:- ATTACHMENT 5/16"x3.5" SS LAG BOLT DETAIL WITH MIN 2%2" THREAD IllO EMBEDMENT, SEALED 'Fitt) JILL ■ PENETRATION ANSI B 11" X17" 2 ATTACHMENT DETAIL (ENLARGED SECTION VIEW) TRUSSES SHEET NUMBER PV-3 SCALE: NTS NOTES :AC DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER. NOTE: NOTE: • ALL GROUNDING TO COMPLY WITH NEC 690.47. GROUNDING ELECTRODE CONDUCTOR/SYSTEM OThEEKU)• ROOF TOP CONDUIT SHALL BE LOCATED MIN.7/8" BONDING JUMPER NOT REQUIRED FOR SOLAREDGE ABOVE ROOF SURFACE. POWER OPTIMIZER.PROPERLY INSTALLED SYSTEM �n =n n n • ALL TERMINALS SHALL BE MIN.90 DEG.C RATED. MEETS THE REQUIREMENTS OF NEC 690.35 FOR II�JLnJLI II�JI^\\l`�JI�II�JV,\/U UNGROUNDED PV POWER SYSTEMS.PROVIDE EQUIPMENT GROUNDING PER MANUFACTURER'S c �nn��nn�7 REQUIREMENTS IN COMPLIANCE WITH THE NEC. ( H Lho lU,�\\��VV// ENPHASE ENCHARGE-10-1 P-NA GREEN THINK ENERGY LLC 10E NEMA 0- (3)#10 AWG THWN-2 50 HARRISON STREET, ( ) (1)#8 AWG GND /A\ SUITE 202B L - 3/4"PVC OR EMT CONDUIT RUN HOBOKEN,NJ 07030 C > I www.GreenThinkEnergy.com 01JWO IA CONTRACTOR NAME:N/A ADDRESS:N/A (3)#10 AWG TC-ER TRUNK CABLE I t (N)ENPHASE ENPOWER PHONE#:N/A R (1)#6 BARE COPPER GND SMART SWITCH, LICENSE#:N/A WIRELESS COMMS KIT MICROGRID INTERCONNECT DEVICE, REVISIONS 200A RATED 240V 1+ DESCRIPTION DATE REV 12 MODULE IN BRANCH CIRCUIT 1 CTRL 35A T- REDLINE 06iO4i2021 A r v v v 7 (3)#6 AWG THWN-2 REDLINE 06/08/2021 B ° (1)#8 AWG GND (N)125A ENPHASE IQ 1"PVC OR EMT CONDUIT RUN • • • COMBINER 3 BOX DYKE SIGNATURE&SEAL JUNCTION BOX 10A _ 0 600 V,NEMA 3 'V 'V UL •LISTED ~O °- FUSED AC DISCONNECT, 20A • 0 60A,2P,SIEMENS m I I a n 0000--• I #GF222NR,240V 3R FUSED 1�A n - ° ° 60A FUSED •• (E)MAIN SERVICE Q I 0 0-• 30A '1 /1 PANEL,200A RATED, 10A �� _ . 240V 4 MODULE IN BRANCH CIRCUIT 2 —Q V °°o--• IF o rH I r+ v v v 1 r--I -- ---- LJ ] rtT 1 / / i I • (N)MAIN BREAKER TO PROJECT NAME • • • L - ENPHASE ENVOY ---- -- - Jr > HOUSE 240 V,200A/2P I -i- (BOTTOM FED) n (3)#1 AWG THWN-2 Q 1-EE1- (1)#6 AWG GND —0 O UTILITY:PSE / / / 3/4"PVC OR EMT CONDUIT RUN LINE SIDE TAP METER NO:-N/A (3)#10 AWG THWN-2 2P 40A MAIN BREAKER L----- A - n (3)#10 AWG THWN-2 (3)#10 AWG THWN-2 -o L. (1)EGC#8 THWN-2 (1)#8 AWG GND SOME LOADS FROM MSPN V 3/4"PVC OR EMT CONDUIT RUN 3/4"PVC OR EMT CONDUIT RUN _o TO BE RELOCATE TO THIS #8 GROUND TO 0 N NEW SUB PANEL GROUNDING ELECTRODE TO UTILITY GRID Li.1 co CONDUCTOR(GEC) Q 2 cr) �o U jQ r 2 MODULEv- IN BRANCH CIRCUIT 3 _ H �. < Q 40A Q C LJ C LLl l�/ l�/ (N)125A SUB PANEL,240V ~ LL ti ti i A (BACKUP LOADS PANEL) O v 0 Q I - 04-HOYMILES:HM-1200N(240V) Q INVERTERS F- - 01 -HOYMILES:HM-600N(240V) INVERTER SHEET NAME SINGLE LINE DIAGRAM SHEET SIZE ANSI B 11" X17" I ELECTRICAL SINGLE LINE DIAGRAM SHEET NUMBER SCALE: NTS PV-4 AC CONDUCTOR AMPACITY CALCULATIONS: AC CONDUCTOR AMPACITY CALCULATIONS: INVERTER SPECIFICATIONS o CSC _\_ FROM ROOF TOP JUNCTION BOX TO IQ COMBINER BOX FROM ENPHASE EMPOWER SWITCH TO MSP MANUFACTURER/MODEL# HM-1200N HOYMILES M NOMINAL OUTPUT CURRENT 5 AMP 1I n I\`IE AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT NOMINAL OUTPUT VOLTAGE 240 VAC C 1 JJ IIJJ- IJ U�UUU PER NEC 310.15(B)(2)(c): +22° EXPECTED WIRE TEMP (°C): 22° a ELETM7EXPECTED WIRE TEMP (°C): 22° + 22° TEMP CORRECTION PER NEC TABLE 310.15: 1.05 INVERTER SPECIFICATIONS TEMP CORRECTION PER TABLE 310.15: 0.82 CIRCUIT CONDUCTOR SIZE: 6 AWG MANUFACTURER/MODEL# HM-600N HOYMILES GREEN THINK ENERGY LLC #OF CURRENT CARRYING CONDUCTORS: 6 CIRCUIT CONDUCTOR AMPACITY: 65A 50 HARRISON STREET, CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a): 0.80 #OF CURRENT CARRYING CONDUCTORS: 3 NOMINAL OUTPUT CURRENT 2.46 AMP SUITE 202B 7030 CIRCUIT CONDUCTOR SIZE: 10 AWG HOBOKEN,kENJ ergy CONDUIT FILL PER NEC 310.15(B)(2)(a): 1 NOMINAL OUTPUT VOLTAGE 240 VAC www.GreenThinkEnergy.com CIRCUIT CONDUCTOR AMPACITY: 35 A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): 1.25 X OUTPUT CURRENT OF LOAD CENTER+ ENPHASE ENCHARGE CONTRACTOR REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B): PEAK OUTPUT CURRENT NUMBER OF CURRENT NAME:N/A PERCENT OF CARRYING CONDUCTORS IN ADDRESS:N/A 1.25 X MAX AC OUTPUT CURRENT X#OF INVERTERS PER STRING 1.25 X(22.46 + 24.6) = 58.82A PHONE St.N/A STRING 1 : 1.25 X 5 X 3 = 18.75A VALUES EMT LICENSE#:N/A STRING 2 : 1.25 X 5 X 1 = 6.25A .80 4-6 REVISIONS STRING 3 : 1.25 X 2.46 X 1 = 3.07A DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.15: 70.50 10 7-9-20 DESCRIPTION DATE TEMP CORR. PER NEC 310.15 XREDLINE 06/04/2021 0 DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.15 CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a)X TEMP CORR. PER NEC TABLE 310.15 X AMBIENT TEMPERATURE SPECS REDLINE 06/08/2021 CIRCUIT CONDUCTOR AMPACITY= CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a)X 1.05 X 1.00 X 65 = 68.25A RECORD LOW TEMP -9 CIRCUIT CONDUCTOR AMPACITY= 0.82 X 0.80 X 35 = 22.96A ci AC CONDUCTOR AMPACITY CALCULATIONS: AMBIENT TEMP(HIGH TEMP 2%) 22° SIGNATURE&SEAL CONDUIT HEIGHT 0.5" ROOF TOP TEMP 44° FROM IQ COMBINER BOX TO ENPHASE CONDUCTOR TEMPERATURE RATE 75° EMPOWER SWITCH EXPECTED WIRE TEMP (°C): 22° TEMP CORRECTION PER NEC TABLE 310.15: 1.05 PROJECT NAME CIRCUIT CONDUCTOR SIZE: 10 AWG �/ CIRCUIT CONDUCTOR AMPACITY: 35A L.L Q #OF CURRENT CARRYING CONDUCTORS: 3 D (f) CONDUIT FILL PER NEC 310.15(B)(2)(a): 1 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): 1.25 X OUTPUT CURRENT OF LOAD CENTER I- j 1.25 X 22.46 =28.07A U < W 00 DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.15: r �_ TEMP CORR. PER NEC 310.15 X , • j CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a)X Q E > CIRCUIT CONDUCTOR AMPACITY = Q ui 1.05X1.00X35 = 36.75A � w ELECTRICAL NOTES 0 Q 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET III ENVIRONMENT. 3.)WIRING, CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY SHEET NAME TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. WIRING 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL CALCULATION COMPLY WITH NEC 110.26. 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL SHEL I DILL APPLICABLE CODES AND STANDARDS. ANSI B ■ 6.)WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED,THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 1 1" X 1 7" 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.. SHEET NUMBER PV-5 AWARNING A ARNING PHOTOVOLTAIC POWER SOURCE oeyiEK CAUTION LHII HE n PHOTOLTAICSTE PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED COMBINER PANEL LABEL LOCATION:DC CONDUIT JUNCTION BOX NO MORE THEN 10FT ���J U�� CODE REF: NEC 690.13(B) ( `J�V�J JiflUn\`VJ/ LABEL LOCATION: BACKFED BREAKER DO NOT ADD LOADS CODE REF:NEC 705.2(4) GREEN THINK ENERGY LLC LABEL LOCATION:AC COMBINER PANEL 15 PHOTOVOLTAIC SYSTEM 50 HARRISON 202B NST REET, SUITETE LITY DINNECT SWITCHHOBOKEN,NJ 07030 CODE REF:NEC 690.12(B) www.GreenThinkEnergy.com AWARNING ` LABEL LOCATION:AC DISCONNECT CONTRACTOR A AWARNING I N G CODE REF: UTILITY NAME:N/A INVERTER OUTPUT CONNECTION p ADDRESS:N/A PHONE#:N/A DO NOT RELOCATE THIS ELECTRICAL SHOCK HAZARD LICENSE#:N/A OVERCURRENT DEVICE TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN REVISIONS LABEL LOCATION:BACKFED BREAKER THE OPEN POSITION DESCRIPTION DATE REV CODE REF:2017 NEC 705.12(2)(3)(b) DC VOLTAGE IS ALWAYS PRESENT REDLINE 06/04/2021 A WHEN SOLAR MODULES ARE AWARN I N G ■ REDLINE 06/08/2021 B WARNING EXPOSED TO SUNLIGHT A A GENERATION SCOURCE IS CONNECTED TO THE SUPPLY(UTILITY) LABEL LOCATION:DC DISCONNECT,COMBINE BOX ELECTRICAL SHOCK HAZARD 3 SIDE OF THE MAIN SERVICE DISCONNECT.FOLLOW THE PROPER CODE REF:NEC690.13(B) POWER TO THIS SERVICE IS ALSO SUPPLIED SIGNATURE&SEAL LOCK-OUT/TAG-OUT PROCEDURES TO ENSURE THE PHOTOVOLTAIC IF GROUND FAULT IS INDICATED SYSTEM UTILITY DISCONNECT SWITCH IS OPENED PRIOR TO FROM THE FOLLOWING SOURCES WITH PERFORMING WORK ON THIS DEVICE ALL NORMALLY GROUNDED A PV SOLAR BREAKER CONDUCTORS MAY BE DISCONNECTS AS SHOWN LABEL LOCATION: (IF APPLICABLE)SUPPLY SIDE TAP UNGROUNDED AND ENERGIZED LOAD PANEL CODE REF:UTILITY DO NOT RELOCATE THIS �\ OVERCURRENT DEVICE LABEL LOCATION:AC DISCONNECT _ COMBINER BOX SERVICE PANEL PV ARRAY / PROJECT NAME A PHOTOVOLTAIC AC DISCONNECT CODE REF: NEC 690.5(C) RATED AC OPERATING CURRENT: 22.46 AM LABEL LOCATION:MAIN PANEL JUNCTION BOX - DEAD FRONT Q II NOMINAL OPERATING AC VOLTAGE: 240 VAC CODE REF:NEC 705.12(B)(2)(3)(B) D j LABEL LOCATION:MAIN PANEL AC DISCONNECT(S) CODE REF: NEC 690.54 11 ~ 1— CAUTIONK - LLJ N A DUAL POWER SOURCE SECOND Q ARAPID SHUTDOWN SWITCH �SCORCE IS PHOTOVOLTIC Q � FOR SOLAR PV SYSTEM LABEL LOCATION:SERVICEA METER MAIN PANEL S Q CODE REF: UTILITY — G 2 w LABEL LOCATION:MAIN PANEL ti CODE REF:NEC 690.12 — O U A WARNING - - 0 Q z A I a ELECTRICAL SHOCK HAZARD - F- TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED SHEET NAME IN THE OPEN POSITION - PLACARDS LABEL LOCATION:COMBINER PANEL AC DISCONNECT I I I I ios. W JUNCTION BOX INVERTER(S) UM ACFI_CCpUEIBAIEESSi CODE REF:NEC 690.13(b) SHEET SIZE ANSI B APHOTOVOLTAIC LLLOAD CENTER 11" X 17" SYSTEM METER FUSED AC SHEET NUMBER UTILITY - DISCONNECT PV-6 coi-AEEK iii, maimimmlii in IIIH_HE HPr TP 1 - 2 Wf r H Pro STP3105 - 20/Wfb r o EHEhoy 0 5 3 05 0/ b J SUNTECH y J SUNTECH STP305S - 20/Wfb STP305S - 20/Wfb GREEN THINK ENERGY LLC 50 HARRISON STREET, STP300S - 20/Wfb STP300S - 20/Wfb SUITE 202B HOBOKEN,NJ 07030 Electrical Characteristics www.GreenThinkEnergy.com 310 Watt 992139.11s210.001 STC STP3105-20/ STP305S-20/ STP3005-20/ Wfb Wfb Wfb CONTRACTOR 942137.11s110.041 �� NAME:N/A MONOCRYSTALLINE SOLAR MODULE Oral ,na.. -• .• Maxi rnum Power at STC(Pmax) 310W i 305W 300W ADDRESS:N/A \ I'aAS.t Optimum Operating Voltage(Vmp) 33.1 V 32.8V 32.5 V PHONE#:N/A °dual.b. `�\ ' Features Grounding miss BE Optimum Operating Current(Imp) 9.37 A 9.30 A 9.23 A LICENSE#:N/A \ 8-14%910.5580.351 Sarosdy Open Circuit Voltage(Voc) 40.2 V 39.8 V 39.6 V REVISIONS High module conversion PID resistant I*j� Short Circuit Current(Isc) 9.87 A 9.80 A 9.72 A DESCRIPTION DATE 123 IJ) efficiency Advanced cell technology Module efficiency up to PID and qualified materials lead to Module Efficiency 18.9% 18.6% 18.3% REDLINE 06/04/2021 EI �$•9% Resistant - - 18.9%achieved through high resistance to PID Operating Module Temperature 40°Cto+85°C REDLINE 06/08/2021 ri advanced cell technology and A iA F. Maximum System Voltage 1000V DC(UL) - manufacturing capabilities (Back View) _ - Section A-A Maximum Series Fuse Rating 20 A I I Positive tolerance p p Suntech current sorting } o IL�J ! Power Tolerance 0/+5 W SIGNATURE&SEAL I m _. I„III.III1ij� STC:Irradiance 10OW/m',module temperature 25°C,AM=1.5; Positive tolerance of up to p © process ^ I" Tolerances of Pma hoc and lsc are all within H-5%. 0/+5w 5W delivers higher outputs 2% System output maximized by 0.8104151 �IIIIIII reliablity reducing mismatch losses up 3511.381 (Front view) ''• vlor STP310S-20/ STP3055-20/ STP3005-20/ to 2%with modules sorted& IIIIII I III.'._. Note:mm[inch] - Wfb Wfb Wfb packaged by amperage Maximum Power at NMOT(Pmax) 232.6 W 228.3 W 225.0 W Extended load tests Withstanding harsh Optimum Operating Voltage(Vmp) 30.8V 30.5 V 30.3 V riModule certified to withstand ® environment Optimum Operating Current(Imp) 7.55 A 7.49 A 7.43 A front side maximum static Reliable quality leads to a 3800Pa a h P 9 Open Circuit Voltage(Voc) 37.6V 37.1 V 37.0 V x 5400Pa test load(5400 Pascal)and """men` better sustainability even in Current-Voltage&Power-Voltage Curve(3105) Short Circuit Current(lsc) 7.97 A 7.92 A 7.85 A PROJECT NAME rear side maximum static test harsh environment like desert, 32 3. NMOT:Irradiance 800 W/ma,ambient temperature 20 c,AM=1.5,wind speed 1 m/s; loads(3800 Pascal)* farm and coastline Q // ** Temperature Characteristics Certifications and standards: aus ' ' [ Mcs e 3a 2. Nominal Module Operating Temperature(NMOT) 42±2°C D IEC61215,IEC61730,conlormiryroCE �` n �� / 3 .0€ Temperature Coefficient of Pmax -0.37%/°C I ., E \ 25a Temperature Coefficient of Voc -0.304%/°C H I- 7 Trust Suntech to Deliver Reliable Performance Over Time Special 5 busbardesign d Temperature Coefficient of Ix 0.050%/°C U N •World-class manufacturer of crystalline silicon photovoltaic modules The unique cell design leads 2 I ao w 00 •Unrivaled manufacturing capacity and world class technology reduction in electrodes ' I "^ Q •Rigorous quality control meeting the highest international standards: resistance,shading area and 1�1 Mechanical Characteristics U - Q raise in conversion efficiency. 0 0 20 20 30 .d 0 Solar Cell Monocrystalline silicon 6 inches ISO 9001:2008,ISO 14001:2004 and 15017025:2005 Y Residual stress distribution can votege m •Regular independently checked production process from international No.of Cells 60(6 x 10) accredited institute/com be more even,reducing the -t0000-a00W/m-a0, 0w/s-,00wrw,-200wom, Dimensions ons x x (65.0x x Dii 1650 99235mm 39.1 1.4 inches) Q •Tested for harsh environments(salt mist,ammonia corrosion and sandanY w,micro cracks risks. C U) Weight 18.3 kgs(40.3 lbs.) G U J blowing testing:IEC 61701,IEC 62716,DIN EN 60068-2-68)*** Front Glass 3.2 mm(0.13 inches)tempered glass (1) •Long-term reliability tests •2 x 100%EL inspection ensuring defect-free modules Frame Anodized aluminium alloy Q Dealer information Junction Box IP68 rated(3 bypass diodes) N- O Industry-leading Warranty based on nominal power IP68 Rated Junction Box 2 Ls) U Output Cables 4.0 mm2(0.006 inches'),symmetrical lengths(-)1000mm(39.4 •97.5%in the first year,thereafter,for The Su ntech I P68 rated inches)and(+)1000mm(39.4inches) 0 Q years two(2)through twenty-five junction box ensures an Connectors MC4 compatible Z (25),0.7%maximum decrease from outstanding waterproof 1 Q /ndus/Ty/eadin MODULE's nominal power output level,supports installations r year,ending wit the 80.7% in all orientations and E * 91inearKarranty i the25thyea afteh hedefined reduces stress on the cables. Packing Configuration s -... WARRANTY STARTING DATE.**** High reliable performance, Container SHEET NAME 1 10 25.12-year product warranty low resistance connectors Pieces per pallet 30 30 •25-year linear performance ensure maximum output Pallets per container 6 28 EQUIPMENT warranty for the highest energy production. Pieces per container I 1s0 840 SPECIFICATION Information on how to install and operate this product is available in the installation instruction.All values indicated in this data sheet are subject to change without prior announcement.The specifications may vary slightly.All specifications are in accordance with standard EN 50380.Color differences of the modules relative to the figures as well as discolorations of/in the modules which do not impair their proper functioning are possible and do not constitute a deviation from the specification. *Please refer to Suntech Standard Module Installation Manual for details. **WEEE only for EU market. SHEET SIZE ***Please refer to Suntech Product Near-coast Installation Manual for details. ****Please refer to Suntech Product Warranty for details. ANSI B 11" X17" ©Copyright 2019 Suntech Power www.sunt-ch-power.com UL-STP-Wfb-NO2.01-Rev 2019 ©Copyright 2019 Suntech Power www.sunt-ch-power.com UL-STP-Wfb-NO2.01-Rev 2019 SHEET NUMBER PV-7 ia, or H hoymiles �' hoymiles The World's Safest ,' Ei1L.37 solar solution for you and your family GREEN THINK ENERGY LLC 50 HARRISON STREET, SUITE 202B __. IIIIII0 Ilk>* HOBOKEN,NJ 07030 Model HM-1000 HM-1200 HM-1500 www•GreenThinkEnergy.com CONTRACTOR _. .�— �. NAME:N/A 1� Input Data (DC) ADDRESS:N/A Commonly used module power(W) 200-310 240-380 300-470 PHONE#:N/A Module compatibility 60-cell or 72-cell PV modules 60-cell or 72-cell PV modules 60-cell or 72-cell PV modules LICENSE#:N/A ••r ' Peak power MPPT voltage range(V) 27-48 29-48 36-48 REVISIONS Start-up voltage(V) 22 22 22 DESCRIPTION DATE REV fill'i i 1 Operating voltage range(V) 16-60 16-60 16-60 REDLINE 06/04/2021 A REDLINE 06/08/2021 B to 41Maximum input voltage(V)11 Maximum input current(A) 4*10.5 4*11.5 4*11.5 f Output Data (AC) SIGNATURE&SEAL r. 44:a ! 'm Rated output power(VA) 1000 1200 1500 Rated output current(A) 4.55 4.35 4.17 5.45 5.22 5 6.82 6.52 6.25 �i� ZCINominal output voltage/range(V) 220/180-275' 230/180-275'240/180-275' 220/180-275' 230/180-275' 240/180-275' 220/180-275' 230/180-275' 240/180-275' Nominal frequency/range(V) 50/45-55'or 60/55-65 1 50/45-55 1 or 60/55-65 1 50/45-55'or 60/55-65 1 ‘41 FPI Power factor(adjustable) >0.99 default >0.99 default >0.99 default 1111•11111111r4/,a 0.8 leading...0.8 lagging 0.8 leading...0.8 lagging 0.8 leading...0.8 lagging Total harmonic distortion <3% <3% <3% x Maximum units per branch' 5 5 5 4 4 4 3 3 3 PROJECT NAME z 4 Efficiency Q 'W CEC peak efficiency 96.70'36 96.70% 96.70% U) �' CEC weighted efficiency 96.50% 96.50% 96.50% D Y 25 E "AR\ Nominal MPPT efficiency 99.80% 99.80% 99.80% I—WARRANTY/ H M-1000/1200/1500 Nighttime power consumption(mW) <50 <50 <50 n/ 0 N Mechanical Data L<L LLJ 00 The Best in Its Class! The Microinverter Ambient temperature range(°C) -40--+65 '`v Q with reactive power control for 4 solar panels Dimensions(WxHxD mm) 280 x 176 x 33 I \ Weight(kG) 3.75 < S Enclosure rating Outdoor-NEMA(IP67) 2 Q (/) Highlights Cooling Natural convection-No fans �^ • Easy installation, just plug and play Features �J, ~ • External antenna for stronger communication with DTU Communication 2.4GHz Proprietary RF(Nordic) C ' 0 • Power factor (adjustable) 0.8 leading......0.8 lagging Monitoring Hoymiles MonitoringSystem G ix) g...... gg' g 0 Q VDE-R-N 4105:2018,EN 50549-1:2019,VFR 2019, • The highest power density microinverter on the market Compliance 2 ZZ IEC/EN 62109-1/-2,IEC/EN 61000-6-1/-2/-3/-4,IEC/EN 61000-3-2/-3 • Compliant with VDE-AR-N 4105: 2018 8/ EN50549-1: 2019 "1 Nominal voltage/frequency range can be changed due to the requirements of local power department. H "2 Refer to local requirements for exact number of microinverters per branch. • High reliability; NEMA (IP67) enclosure; 6000V surge protection _ High Reliability Based on World's Top Supplier Part ers SHEET NAME Wk Safer °° Smarter =_= a More Powerful \�/ More Reliable CREE= EQUIPMENT lir MICROCHIP EPCOS SPECIFICATION O sales@hoymiles.com © +86-571-28056101 O www.hoymiles.com Infineon a I S NIPPON t SHEET SIZE Ilrsrtwrus J IICHEMI.CONI ANSI B 11" X 17" SHEET NUMBER PV-8 7: cia, ho miles w hoymiles The World's Safest c o � � solar solution for you and your family GREEN THINK ENERGY LLC / 50 HARRISON 2gREET, HOBOKEN,N0J 07030 www.GreenThinkEnergy.com I.. - - CONTRACTOR Model HM-600N HM-700N HM-800N NAME:N/A ADDREis::N/A 1 IIIIPIIPPHONEN/Alir Input Data (DC) LICENS #:N/A Commonly used module power(W) 240-380 280-440 320-500 REVISIONS Module compatibility 60-cell or 72-cell PV modules 60-cell or 72-cell PV modules 60-cell or 72-cell PV modules DESCRIPTION DATE REV # Peak power MPPT voltage range(V) 29-48 33-48 34-48 REDLINE 06/04/2021 A NIIIIIIIIMUM 4 I 96� Start-up voltage(eV) 22 22 22 REDLINE 06/08/2021 B Operating voltag range(V) 16-60 16-60 16�60 �� Maximum input voltage(V) 60 60 60 SIGNATURE&SEAL j� Maximum input current(A) 2*11.5 2*11.5 2*1 2.5 / •\ 1 / _Irk /1111 Output Data (AC) %,� Peak output power(VA) 600 700 800 . --t / Maximum continuous output power (VA) 590 696 766 \^ :----, Maximum continuous output current(A) 2.46 2.84 2.9 3.35 3.19 3.68 ; Nominal output voltage/range(V) 240/211-264' 208/183-228' 240/211-264' 208/183 2281 240/211 2641 208/183-228' / Nominal frequency/range(Hz) 60/55-65 1 60/55-65 ' 60/55-65 1 >0.99 default >0.99 default >0.99 default PROJECT NAME Power factor(adjustable) 43 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging Q Total harmonic distortion <3% <3% <3% D a Maximum units per branch' 6 5 5 4 5 4 2 D �YEAR ", Efficiency I— WARRANT/ HM-600N/700N/800N CEC peak efficiency 96.70% 96.70% 96.70% N 0 N CEC weighted efficiency 96.50% 96.50% 96.50% < LI co The best daisy-chain microinverter with Nominal MPPT efficiency 99.80% 99.80% 99.80% _ reactive power control for 2 solar panels Nighttime power consumption(mW) <50 <50 <50 (— Mechanical Data Highlights Ambient temperature range(°C) -40—+65 CQ Dimensions(WxHxD mm) 250 x 170 x 28 G w • Easy installation,just plug and play (I ti ft Weight(kG) 3.0(including 2.32m AC cable) • External antenna for stronger communication with DTU Enclosure rating Outdoor-NEMA(IP67) '- 0 • Power factor (adjustable) 0.85 leading......0.85 lagging Cooling Natural convection— No fans Q • Compliant with CA Rule 21 & U.S. NEC 2014/2017 690.12 rapid shutdown Features 0 z • High reliability; NEMA (IP67) enclosure; 6000V surge protection Communication 2.4GHz Proprietary RF(Nordic) = Q Monitoring Hoymiles Monitoring System ��� ��� Warranty Up to 25 years �� More Reliable R Safer Smarter •.. More Powerful I 'WI Compliance UL1741,IEEE1547,UL1741 SA(240Vac),CA Rule21(240Vac),CSA C22.2 No.107.1-16,FCC 15B,FCC 15C SHEET NAME Conforms with NEC-2014 and NEC-2017 Article 690.12 EQUIPMENT / PV Rapid Shutdown and CEC-2018 Sec 64-218 Rapid Shutdown of PV Systems SPECIFICATION 0� s a l e s©h o y m i l e s.c o m ® +86-571-280 56101 O w w w.h o y m i l e s.c o m *1 Nominal voltage/frequency range can be changed due to the requirements of local power department. \ / *2 Refer to local requirements for exact number of microinverters per branch. SHEET SIZE • ANSI B �/ I 11" X 17" SHEET NUMBER PV-9 0 0 EEEK Datasheet Datasheet 1 III LJ_ I\V E IRONRIDGE Flush Mount System — XR Rails e — c o EHEhow XR10 Rail XR100 Rail XR1000 Rail Bonded Splices GREEN THINK ENERGY LLC 50 HARRISON STREET, SUITE 202E _._-........_._._._...__._._.._...3 - li iiimmolulli M HOBOKEN,NJ 07030 _.-1e k i www.GreenThinkEnergy.com NAME.N CONTRACTOR -.--,All ADDRESS:N/A A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices PHONE#:N/A for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. ucENSE#:N/A • 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-drilling screws REVISIONS • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails DESCRIPTION DATE REV • Clear and black finish • Clear and black finish • Clear anodized finish • Forms secure bonding REDLINE 06/04/2021 A REDLINE 06/08/2021 B Clamps &Grounding e — ..` SIGNATURE&SEAL e UFOs Stopper Sleeves Grounding Lugs Microinverter Kits N ir Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount Mls or POs to XR ' bond modules to rails. into a bonded end clamp. equipment ground. Rails. PROJECT NAME • Fully assembled&lubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size • Sized to match modules • Single tool installation • Kit comes assembled < • Clear and black finish • Clear and black finish • Mounts in any direction • Listed to UL 2703 D Built for solar's toughest roofs. I Attachments e - N— IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to ^ 0 N the limit and proven in extreme environments. FlashFoot2 Slotted L-Feet Bonding Hardware Flush Standoffs Q In 03 Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and — — is also why our products are fully certified, code compliant and backed by a 20-year warranty. I-I 0 I- j CC Strength Tested PE Certified - _ lilt"'— l_tt- _ — G 2 w iiAll components evaluated for superior ® Pre-stamped engineering letters Flash and mount XR Rails Drop-in design for rapid rail Bond and attach XR Rails Raise Flush Mount System Q .- LL structural performance. available in most states. with superior waterproofing. attachment. to roof attachments. to various heights. 5 8 • Twist-on Cap eases install • Secure rail connections • T&Square Bolt options • Works with vent flashing U • Wind-driven rain tested • Slot for vertical adjusting • Nut uses 7/16"socket • 4"and 7"lengths 0 Q Class A Fire Rating Certified to maintain the fire resistance Design Assistant Online software makes it simple to • Mill and black f6inish • Clear and black finish • Assembled and lubricated • Ships assembled I Q ..B.rating of the existing roof. create, share, and price projects. Resources SHEET NAME _. ` Design Assistant �p NABCEP Certified Training SRbft PR'o UL 2703 Listed System 20-Year Warranty -- Go from rough layout to fully a' Earn free continuing education credits, EQUIPMENT NABCEP O Entire system and components meet 0 Twice the protection offered by .. engineered system. For free. while learning more about our systems. SPECIFICATION 'a�0 i0 IfOilr;i Ga C�e.COYii/G>✓Slgn ,4,,E t.i V:"ait ll Y-.:+'t„j`.1..4.JIf:/-'.ii.�➢dzi➢y newest effective UL 2703 standard. competitors. SHEET SIZE ANSI B 11" X 17" ' - reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.30 SHEET NUMBER PV-10 00EEEK 'MAE -- IRON RIDGE Integrated Grounding System Installation Overview GREEN THINK ENERGY LLC 50 HARRISON STREET, Install Roof Attachments SUITE 202B Simplified Grounding HOBOKENN/A ,NJ 07030 — • Install appropriate roof flashing and/or standoff for roof type. i w E:w.GreenThinkEnergy.com For Greater Safety & Lower Cost 1 CONTRACTOR •Attach L-Feet to flashing or standoff. � NAwM Traditionally, solar modules are grounded by attaching . ADDRESS:N/A lugs, bolts or clips to the module frame, then connecting PHONE#:N/A Prepare Rail Connections LICENSE these to a copper conductor that runs throughout the '-'�l„.., . ��• REVISIONS array.This process adds time and cost to the installation, cilr • Insert splice into first rail, then secure with Grounding Strap and (! and often results in improper grounding, creating self-drilling screw. C DESCRIPTION DATE REV significant long-term safety risks. REDLINE j06/04/2021 A • Slide second rail over splice,then secure with opposite end of \ REDLINE os�o8�zoz1 B The IronRidge Integrated Grounding System solves these Grounding Strap and self drilling screw. challenges by bonding modules directly to the mounting _ SIGNATURE&SEAL rails.This approach eliminates separate module L. Mount&Ground Rails grounding hardware, and it creates many parallel III grounding paths throughout the array, providing •Attach rails to L-Feet and level rails. ri• greater safety for system owners. Grounding Mid Clamp • Install one Grounding Lug per row of modules. Each Grounding Mid Clamp pierces through the • Connect GroundingLugto groundingconductor. anodized coatings of both the module frame and ff the mounting rail to form secure electrical bonds, which are repeated throughout the array. # Install Modules&Clamps PROJECT NAME � /I ' �� �� 'I/ 4 • Install first module usingEnd Clamps and GroundingMid Clamps. 7 ry %� l�� // 1 ��I� � ����� %j • Install additional modules using Grounding Mid Clamps. D ®1� 1/ � 1 1/ "1iP0i �1 /ii�iii/��i �/ ,/ � �1� ��� /���� ��:� •�•//�//�// • Finish row with a second pair of End Oj �/ ///��j�i/ /1 �� ��/�/1/ 1/ Clamps. ii I// /I// I/ Oil / 1/ � O N �j�►jIi �I/��I � �O� 1/� //1/��i, w o0 OZI % /�I �y �j Testing & Certification - �ij �jj�I ®r -- �.� I/ 1 1// �I BCompatibility ��/'�/�� w �� /® .� •i ��� �/•/�/ IronRidgeIntegratedGrounding r Module Frame .� The _ �/ ® / / / �� ����/ / ��� '� �� �/ //�/4 System has been tested and certified to _ Dimension Range �j �/ �® �/ �/ UL 2703 by Intertek Group plc. 2 Q Uj �i/� �`� /, '�� �� A 31.0mm -51.0mm ��/ ����. �f/ ' A B 5.08mm (minimum) 2 w ' / 4 ', UL 2703 is a proposed UL standard _ (� N- r ��. / for evaluatingsolar module mountingQ '//��y � \ Any module frames whose parameters are not listed in the /r '� 4# �,, and clamping devices. It ensures these provided table have not been tested for compatibility. Q --// ``�f` devices will maintain strong electrical and 1 \��.j�� 3 mechanical connections over an extended O Z Iperiod of time in extreme outdoor The Grounding Clamp has proven robust in grounding 60-cell and i I 72-cell solar module frames with box construction and a range of = Q /���, A environments. anodization thicknesses. .��. © � �._ , 7)4.14, The testing process closely mirrors that All solar modules listed to UL 1703 and with frame construction . Grounding Strap ! of UL 1703,the solar module testingSHEET NAME within the parameters stated above are compatible with the 4/ �� ,� Grounding Straps are used to / standard, includingtemperature and Y -' bond rail-to-rail connections. / Grounding Lug p IronRidge Integrated Grounding System. EQUIPMENT humiditycycling, electricalmechanical They are only required on the eectrica and rail with the groundinglug. Asingle Grounding Lug i SPECIFICATION _, load testing, and manufacturing quality O Go to ironridge.com/ig IIIIIconnects an entire row of PV modules to the reviews. grounding conductor. __I SHEET SIZE ANSI B 11" X17" ©2013 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information. SHEET NUMBER PV-11 A oTHEEK Ems— JJ[_HE D /lam IRON RIDGE UFO Family of Components System Diagram ( LELEI37 GREEN THINK ENERGY LLC 50 HARRISON STREET, Simplified Grounding for Every Application _ —_ _m_ —_ _ SUITE 202B El" 0 —� O — — —O 0 • I_;= HOBOKEN,NJ 07030 www.GreenThinkEnergy.com The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules Ain.a.v--_ �_a CONTRACTOR directlyto IronRidge XR Rails.All system types that feature NAME:N/A 9 Y YP ADDRESS:N/A the UFO family—Flush Mount,Tilt Mount and Ground PHONE St.N/A Mount—are fully listed to the UL 2703 standard. LICENSE#:N/A Will Q _ _ _m_ _ -Q Q ( = REVISIONS UFO hardware forms secure electrical bonds with both the DESCRIPTION DATE REV module and the rail, resulting in many parallel grounding : REDLINE 06/04/2021 A paths throughout the system. This leads to safer and more REDLINE 06/08/2021 B reliable installations. ( .....m. J0 0= - -m- - -O 0 • A SIGNATURE&SEAL Of.) Stopper Sleeve Universal Fastening Object(UFO) The Stopper Sleeve snaps The UFO securely bonds solar modules to XR onto the UFO,converting it into Rails.It comes assembled and lubricated,and _ _ _ _ _ _ _ a bonded end clamp. can fit a wide range of module heights. O 0— — —m— — —O 0 4 ,4:,.;;Apc • ���� PROJECT NAME ®%®���j� '._�FA �" Q UFO ( Stopper Sleeve • Grounding Lug Bonded Splice Ground Wire /4'. weir/ , t-/�c '5 4 Approved Enphase microinverters can provide equipment grounding of IronRidge systems,eliminating the need for N (� N ® r L.L � grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the w ���� �dij���/ same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. Q co in 0) 7,:, I= Y� ` UL Certification — Q lr �X.,'� - _X / Al Cross-System Compatibility '�/�'� �� The IronRidge Flush Mount, Feature I Flush Mount Tilt Mount Ground Mount 2 w '/ �� Tilt Mount, and Ground Mount XR Rails V v XR1000 Only Cn N r Bonded Splice /At Systems have been listed to UL — - Q Each Bonded Splice uses UFO/Stopper V V V C O - " self-drilling screws to form �;;m 2703 by Intertek Group plc. pp c U a secure connection.No �lL Bonded Splice d N/A bonding strap needed. / `L M"'rr UL 2703 is the standard for O Z /� evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array I Q N. systems. It ensures these devices microinverters Enphase M250 72, M250 60, M215 60, C250 72 will maintain strong electrical and &Power Darfon-MIG240, MIG300, G320, G640 Grounding Lug mechanical connections over Optimizers SolarEdge P300, P320, P400, P405, P600, P700, P730 T- of A single Grounding Lug Bonded Attachments p g SHEET NAME an extended period of time in connects an entire rowThe bonding bolt attaches Fire Ratin Class A Class A N/AEQUIPMENT PV modules to the and bonds the L-foot to the extreme outdoor environments. g grounding conductor. rail.It is installed with the ' Tested or Evaluated with over 400 Framed Modules SPECIFICATION same socket as the rest of the 1 Modules system. O Go to IronRidge.com/UFO Refer to installation manuals for a detailed list. i SHEET SIZE � ANSI B ©2016 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.0 Zilk! 1 1 X 1 7 SHEET NUMBER PV-12 SCC Data Sheet Enphase Encharge 10 ` a 71 ���� S� Enphase Storage System MODEL NUMBER GREEN THINK ENERGY LLC 50 HARRISON STREET, ENCHARGE-10-1 P-NA Encharge 10 battery storage system with integrated Enphase Microinverters and battery SUITE 202B management unit(BMU).Includes: HOBOKEN,NJ 07030 -Three Encharge 3.36 kWh base units(B03-A01-US00-1-3) www.GreenThinkEnergy.com -One Encharge 10 cover kit with cover,wall mounting bracket,watertight conduit hubs,and interconnect kit for wiring between batteries(B10-C-1050-0) CONTRACTOR ACCESSORIES NAME:N/A Enphase M ENCHARGE-HNDL-R1 One set of Encharge base unit installation handles ADDRESS:N/A The Enphase Encharge 10 all-in-one AC-coupled OUTPUT(AC) @ 240 VAC' LICENSE#:PHONE#:N/A /A storage system is reliable,smart,simple,and safe. It is Rated(continuous)output power 3.84 kVA Encharge 10 comprised of three base Encharge 3"storage units,has Peak output power 5.7 kVA(10 seconds) REVISIONS a total usable energy capacity of 10.08 kWh and twelve Nominal voltage/range 240/211—264 VAC DESCRIPTION DATE REV Nominal frequency/range 60/57—61 Hz REDLINE 06/04/2021 A embedded grid-forming microinverters with 3.84 kW Rated output current 16 A REDLINE 06/08/2021 B power rating. It provides backup capability and installers Peak output current 24.6A(10 seconds) can quickly design the right system size to meet the Power factor(adjustable) 0.85 leading...0.85 lagging SIGNATURE&SEAL Maximum units per 20 A branch circuit 1 unit(single phase) needs of both new and retrofit solar customers. Interconnection Single-phase Maximum AC short circuit fault current over 3 cycles 69.6 Arms Round trip efficiency2 89% BATTERY Reliable Total capacity 10.5 kWh Usable capacity 10.08 kWh • Proven high reliability IQ Series Microinverters Round trip efficiency 96% • Ten-year limited warranty Nominal DC voltage 67.2 V • Three independent Encharge storage base units Maximum DC voltage 73.5 V PROJECT NAME • Twelve embedded IQ 8X-BAT Microinverters Ambient operating temperature range -15°C to 55°C(5°F to 131°F)non-condensing Et • Passive cooling(no moving parts/fans) Optimum operating temperature range 0°C to 30°C(32°F to 86°F) Q Chemistry Lithium iron phosphate(LFP) D cn MECHANICAL DATA Smart Dimensions(WxHxD) 1070 mm x 664 mm x 319 mm (42.13 in x 26.14 in x 12.56 in) • Grid-forming capability for backup operation Weight Three individual 44.2 kg(97.4 Ibs)base units plus 21.1 kg(48.7 Ibs)cover and mounting H ~ N • Remote software and firmware upgrade bracket;total 154.7 kg(341 Ibs) 0 N • Mobile app-based monitoring and control Enclosure Outdoor—NEMA type 3R 11J co • Support for self consumption IQ 8X-BAT microinverter enclosure NEMA type 6 r , 2 • Utility time of use(TOU)optimization Cooling Natural convection—No fans v Q Altitude Up to 2500 meters(8200 feet) Q N Mounting Wall mount Q Simple FEATURES AND COMPLIANCE C w Compatibility Compatible with grid-tied PV systems.Compatible with Enphase M215/M250 and IQ Series G • Fully integrated AC battery system Micros,Enphase Enpower,and Enphase IQ Envoy for backup operation. • Quick and easy plug-and-play installation Communication Wireless 2.4 GHz • Interconnects with standard household AC wiring Services Backup,self-consumption,TOU,Demand Charge,NEM Integrity is) !%, Monitoring Enlighten Manager and MyEnlighten monitoring options;API integration 0 Compliance UL 9540,UN 38.3,UL 9540A,UL 1998,UL 991,NEMA Type 3R,AC156 Safe EMI:47 CFR,Part 15,Class B,ICES 003 z Cell Module:UL 1973,UN 38.3 �l • Cells safety tested Inverters:UL 62109-1,IEC 62109-2,UL 1741SA,CAN/CSA C22.2 No.107.1-16,and IEEE 1547 • Lithium iron phosphate(LFP)chemistry for maximum LIMITED WARRANTY 1 safety and longevity Limited Warranty' >70%capacity,up to 10 years or 4000 cycles SHEET NAME 1.Supported in backup/off grid operations 2.AC to Battery to AC at 50%power rating. EQUIPMENT 3.Whichever occurs first.Restrictions apply. SPECIFICATION To learn more about Enphase offerings,visit enphase.com EN P H AS E. ©2021 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Encharge 10,and other trademarks or service names are the trademarks EN PHASE . To learn more about Enphase offerings,visit enphase.com `/ of Enphase Energy,Inc.Data subject to change.2021-03-01 %./ ANSI B 11" X 17" SHEET NUMBER PV-13 Data Sheet Enphase Enpower r w Enphase Ensemble energy management system MODEL NUMBER _ GREEN THINK ENERGY LLC EP260G141-M240US64 Enphase Enpower#marl switch with neutral-loaning Iran#former(NET),Mlcrogrid Interconnect Device(MID), 50 HARRISON STREET, breakers,and screws.Swahili nes gr let-Independent ce*pi lilies of Pv and storage Installations. SUITE 202B ACCESSORIES and REPLACEMENT PARTS HOBOKEN,NJ 07030 www.GreenThinkEnergy.com KA-E3-PC8A-ENS Replacement Enpower.controller prl sled c lrcul I board EP200G-NA-H D-200A Eaton type BR circuit breaker hold-down screw kit,BRHDK125 CONTRACTOR EP206G-Hlr1 Dl--R1 Enpower Installation handle kl'I(girder separately) NAME:N/A 2 3 ADDRESS:N/A TheEntphaseEn ower'v smart switch connects the Circuit breakers(as needed}' Not lneIuded,must order separately: Enphase p p BRK-IDDA-2P 240V •Maln breaker,2 pole,100A,25kAI C,CSR2100 PHONE#:N/A home to grid power,the Enc[large storage system, 8RK-125A-2P-240V •Main breaker,2 pole,125A,25kAEC,CSR2125N LICENSE it N/A EBRK-156A-2P•249V •Main breaker,2 pole,150A,25kA[C.c5R215ON REVISIONS npower and solar PV. It provides mfcrogrfd late rCOrinectiOn BRI-175q 2P-249V • •Ma In breaker,2 po le,175A.25kA€c,l R2175N BRK•240A-2P•243V •Main breaker,2 pole,200A,25SAIC.C3R2209N DESCRIPTION DATE REV device(MID)functionality by automatically detecting 8RK-20A2P-240V-8 •Circuit breaker,2 pole,ZGA,Zak AEC,BR2208 REDLINE 06/04/2021 A and seamlessly transitioning t he home energy system BRK•30A-2P-240V •Circuit breaker.2 pole,30A.10/AIC,8112308 REDLINE 06/08/2021 B BRK-411A•2P•240V •Circuit breaker.2 pole,44A,14k41C,882498 from grid power to backup power in the event of a grid BRK-60A-2P-240V •Circuit beaker,2 pole,69A,10kAIC,8R269 BRK-84A•2P•245V •CIrcull breaker,2 pole.IPOA,19kAIC,BR280 failure. It consolidates interconnection equipment into SIGNATURE&SEAL ELECTRICAL SPECIFICATIONS a single enclosure and streamlines grid independent Assembly rating Continuous opera-Banat 199%of its cal ms F capabilities of I V and storage installations by Nominal walla ge/range(L-L} 240V0C1100-310VAC Voltage measureme nt aneuracy ±1%V nominal(±1.2V L-N a nd±24V L-L) providing a consistent, pre-wired solution for nuxlllaryco Mont forloadcontrolandeecessFtcontrel 24V.iA residential applications. Nominal frequency inane SC Hz l55.53 Hz Frequency measurementaccurae) ±01 He Maximum cont nuous current rat rig 150A Maximum input overcurrenl protection device 200A Maximum outpulovercurrent prated londevlae 200A PROJECT NAME Reliable Maximum overcurrenl protectiondevlce rating for storage branch clrcuit4 80A • DurableNEMAtype3Renclosure Maximum overcurrenl prolectlondevlce rating for PVcomPInerbranchclrcull4 80A Et Q^ --- - Neutral Forming Transformer(NET) •Breaker rating{pre•Installed}:44Abetween Ll and Neutral;44A between L2 a nd Neutral VJ 1 • Ten-year limited warranty ^ •Continuous rerated power:3609VA •Maximum continuous unbalance current 39A 1/121V •Peak rated pourer:B869VA for 34 seta nds w Smart •Peal<unbalanced current 64A(ai 120V for 3/seconds H Ire, 'ENPH A S E MECHANICAL DATA Ct U N • Contra's safe connectivity to the grid Dlmensooua(WxHaD) 50em K91.5cmx24.6cm(19.7 In x361n x9.7in) ,/ 11.1 00 • Automatically detects grid outages GI` Weight 38.5kg(85Ibs) • Provides seamless transition to backup U I Amblertl lemperatcre range �4°G7a+50°C{-4II°Etc 122 F) Cooling Natural convection.plus heal shield Q L.I— S Simple Enclosure environmental rating •Oljtdoor;MEMA type 3R,polycarbo sale co Netruetian Altitude To25110 meters(8200 feet) CC • Connects to the load or service equipment'side of WIRE SIZES to 1rw the main load panel Connections •Main lugs and backup load lugs Cu/AI:1 AM.-MC KCMLL I_ F- • Centered mounting brackets support single stud CAll lugs are rated to 90C) •COP breakers Cu/AI:2AWG-GEE it CNN_ Q mounting •8R breakers(wire provided) SAWS 1-1^ O •AC cambi ner lugs,El/charge lugs,andge nerator lugs 14 AW/I-2 AWG Ls) 0 • Supports conduit entry from the bottom,bottom left •Neutral(large lugs) Cu/AI:5AWG-200.KCMIL 0 0 side,and bottom right side Neutral and ground bars Large bides(5/16-24LINE) 14 AWG-1/0 SING I • Supports whole home and partial hore backup and Smallholes(10-32UNE) 14AWG-6AVM z subpanel backup COMPLIANCE Q • Up to 200A main breaker support Compliance LPL 1741,UL1741 SA,UL1741 PCS,UL1998,UL869A',UL57',UL508.5,UL5I00 mil • Includes neutral-forming transformer far split phase CSA221 No 1071.47 CFR.Part 15.Class B,ICES 943,AC156_ 1 20/240V backup operation 2 Compatible with B RH//K125 Hold-Down Bit to comply with 2917 NEC 714.15E far back-Fed cimu It breakers- SHEET NAME 3.The En power Iss rated 22 kAI C 4 Not Included.!natal ler muat provide properly rated breaker per clrcull breaker lisl above. EQUIPMENT 5.Seellons from these standerds were used during the safelyevaluallon and Included In the UL1741 hating. SPECIFICATION 1.Enpower is not suitable for use as service equipment in Canada. To learn more about Enphase offerings,visit enphase.com ENPHASE. �2dzlEnpceseEergyAllrlgEsresene�Ep �,1eE6�ha�l ,��p�wer,ando r1� 9�r afsery narnesar�l , 1ai<sofr„�lasseENPHASE. SHEET SIZE To learn more about Enphase offerings,visit enphase.com V Erorgy.Inc.Data sulai ctlochange.2021-Dr-25 ANSI B 11 tt X 1711 SHEET NUMBER PV-14