Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File BLD-2021-0393 2005 10th Street
1 C} City of Anacortes Invoice/Permit#: BLD-2021-0393 904 6th Street Applied date: 05/19/2021 P.O.Box 547 Issue date: 05/19/2021 _ 0, Anacortes, WA 98221-0547 (360) 293-1901 Expire date: 11/15/2022 445/ Job Address: 2005 10TH ST Permit Type: PV Solar Permit ANACORTES WA 98221-1421 Project: APN: P56126 Remarks: INSTALL 14 SOLAR PANELS IN 2 ARRAYS ON ROOF MOUNTED 4.34kW pv SYSTEM. Owner: THOMAS FLANAGAN Contractor: TML INTERNATIONAL LLC Address: 2005 10TH ST Address: 6405 E MILL PLAIN BLVD ANACORTES WA 98221-1421 VANCOUVER WA 98661 Phone: (360)293-4090 Phone: (775)842-1905 License#: General Information: Fees: Building Valuation 4959 Building Permit Fee 111.25 Plan Review Fee 72.31 State Building Code Fee Resi 6.50 Total Calculated: 190.06 Deposits/Receipts: 0.00 Total Due: 190.06 The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and examined this application and know the same to be true and correct. /fry SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY T•/'/�/ c \ 4.340 KW DC PV SOLAR SYSTEM - FLUSH MOUNTED 9 PHOTOVOI TATfl r\ln-M'S - - _ - -4 - SCOPE OF WORK • • • I.AN INVERT ER C�'. CAM .U LE IP INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL " • ~ ` +1 - , . '- INSTALLATION OF ROOF MOUNTED SOLAR PV SYSTEM infinity solar DE-ENERGIZE IV- `~TV.,•H:`•,N TED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK _ - 1 i -" _ •- - NEW EQUIPMENT: 1 q. HYPRO STP31 OS-20/WFB-310 WATTS UPON LOSS O• PLC- IN TH•- < ND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL \, •- _ SUNTECH MODULES PRODUCTION/A.D DI:TRIBUTION a VOLTAGE HAS BEEN RESTORED.(NEC 690361) 4 HM-I 200N HOYMILES MICROINVERTER 2.ALL EXTER4Q)-. f - _ C:UnNG(EMT)CONDUIT FITTING SHALL BE RAIN TIGHT - - flp 0 HM-600N HOYMILES MICROINVERTER INFINITY HOME SOLUTIONS THREAD-LESSS r2 - + - 0 HM-300N HOYMILES MICROINVERTER 6405 E MILL PLAIN 3.MODULES AN s -PORTS _UCT RE'.SHALL BE GROUNDED � +^ 4.NAMEPLATES- as:ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER SYSTEM SIZE: 4.340 DC KW POWER RATING a 8a ,traha Tula i'art► st VANCOUVER,WA 98661 DISTRIBUTION fS. +. keARDS,DISCONNECTING SWITCHES,TERMINAL CABINETS, 4.800 AC KW POWER RATING ETC.ALL NAME-.•'] i tA►.FS F;', A'ENTLY ATTACHED AND BE OF SUFFICIENT CAPACITY TO � - RACKING: IRONRIDGE RACKING WITH NANOMOUNT PHONE: 1-800-818-0598 WITHSTAND THE d-•_' L- Q. R 5.JUNCTION BOX/ i will - 'I I..-'AVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR Ti• - -*•'•`- ARRAY AREA: 17.65 SQFT x 14 = 247.10 SQFT APPROPRIATE WATER- VP. 6 CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION *PAX ••� •.. , BOX/COMBINER BOXES PER APPROPRIATE NEC REQUIREMENTS s >th. , j t�" - SITE DETAIL 7.SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS - A` --f `-• ; . UTILITY: PUGET SOUND ENERGY 8.WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS.FIELD _ APPLIED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. l* .. - ; -I<C' ELECTRIC SERVICE: 1 25A 9.JUNCTION,PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE 1 I' � _ - ROOF MATERIAL: MEMBRANE ROOFING WIRING CONTAINED IN THEM CAN BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF L. - !.' - ASCE 7 GROUND SNOW LOAD: 25 PSF MODULE(S)SECURED BY REMOVABLE FASTENERS AND CONNECTED BY A FLEXIBLE WIRING SYSTEM. 4110 t •t '2005a Oth.St, (NEC 69o.34) - ASCE 7.1 O WINDSPEEDS: (3 SEC GUST IN MPH) 1 O.IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM,THE POWER SOURCE SHALL BE LABELED WITH THE . - • iI� A 0001"E@$'' '•1 -'.4. ._ RISK CATERGORY I: 100 FOLLOWING WARNING AT EACH JUNCTION BOX,COMBINER BOX,DISCONNECT AND DEVICE WHERE THE - y hl p POT 11 is. RISK CATEGORY II: 1 1 0 UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE."WARNING-ELECTRIC SHOCK HAZARD. IL. - - ! .� RISK CATEGORY III-IV: 1 1 5 THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT ASCE 7-05 WINDSPEED: 85(3 SEC PEAK GUST IN MPH) MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND - - �--L, r w _ 4 f! t� FAULTS."(NECE 690.35(F)) -s , ,.- 1 Tv 1 1.ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE - �_- . i•• i..' NI - - CODE AUTHORITY I PROTECTED FROM ANY PHYSICAL DAMAGE. 12.ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING - - -- r 2015 WASHINGTON STATE BUILDING CODE(2015 IBC) AGENCY. • f D. -- 2O 15 WASHINGTON STATE ENERGY CODE(2015 IECC) 13.OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. •�+A • n, ..+ 2015 WASHINGTON STATE RESIDENTIAL CODE(2015 INTERNATIONAL 15.CO SPECIFIED A IS NED C THE USE OF COPPERt` ,."• t, .--r. �� M'- RESIDENTIAL CODE WASHINGTON AMENDMENTS 2014 WACS 1-51-2300 PROJECT DETAILS 15.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION, •' SECTION M2302) COMMISSIONING AND ACCEPTANCE WITH THE CLIENT,UTILITY CO.AND CITY INSPECTORS AS NEEDED 16.DRAWINGS ARE DIAGRAMMATIC ONLY,ROUTING OF RACEWAYS SHALL BE AT THE OPTION OF THE 2020 WAC 296-46B(2020 NEC) 4.340 DC KW CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. If, 2017 WASHINGTON CITIES ELECTRICAL CODE(2017 WCEC) 17.IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN,THE CONTRACTOR SHALL NOTIFY AERIAL VIEW 2015 WASHINGTON STATE MECHANICAL CODE(2015 UMC) 4.800 KW CEC-AC RATING ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE.FINAL DRAWINGS WILL BE RED-LINED AND UPDATED 2015 WASHINGTON STATE PLUMBING CODE(2015 UPC) AS APPROPRIATE. MICROINVERTER SYSTEM 18.WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT,ARISES ON THE DRAWINGS OR 2015 WASHINGTON STATE FIRE CODE (2015 IFC) SPECIFICATIONS,THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL 5° 90° MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN TILT AZIMUTH THE SPECIFICATIONS TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM SHEET INDEX REQUIRED BY THE ARCHITECT/ENGINEER. A-1 GENERAL NOTES&PROJECT DATA CUSTOMER INFO 19.ALL BROCHURES,OPERATION MANUALS,CATALOGS,SHOP DRAWINGS,ETC.SHALL BE HANDED A-2 SITE PLAN OVER TO THE OWNER'S REPRESENTATIVE AT THE COMPLETION OR WORK. 20.ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT. A-3 WIRING&MOUNTING PLAN 2005 1 0TH ST 21.THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE lath St lath s E-1 ELECTRICAL SINGLE LINE DIAGRAM WITH THE"SMACNA"-GUIDLINES FOR SEISMIC RESTRAINS OF MECHANICAL SYSTEMS AND PLUMING E-2 ELECTRICAL CALCULATIONS ANACORTES, PIPING SYSTEMS. 1,200510ih St, Q E-3 LABELING REQUIREMENTS WA 98221 22.ALL OF THE LISTED SYSTEMS REQUIRED THAT THE SEISMIC LATERAL FORCE F INCLUDING Anacortes,WA 98221 E-4 EQUIPMENT:PV MODULE SPECIFICATION SHEET CONSIDERATION OF A^P AND R^P BE DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE Anacortes Castle SPACING CAN BE CALCULATED.THE DISTRICT STRUCTURAL ENGINEER CAN APPROVE THE SEISMIC E-5 EQUIPMENT:MICROINVERTER SPECIFICATION SHEET TOM FLANAGAN LATERAL FORCE DETERMINATION. a E-6 EQUIPMENT:MICROINVERTER SPECIFICATION SHEET 23.A COPY OF THE CHOSEN BRACING SYSTEM(S)INSTALLATION GUIDE/MANUAL SHALL BE ON THE JOB $-1 EQUIPMENT:RACKING-DATA SHEET SITE PRIOR TO STARTING THE INSTALLING OF HANGERS AND/OR BRACES. S-2 EQUIPMENT:RACKING-DATA SHEET 24.WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING NON-PRESTRESSED REINFORCED CONCRETE,USE CARE AND CAUTION TO AVOID CUTTING OR S-3 EQUIPMENT:RACKING-GROUNDING DAMAGING THE REINFORCED BARS.WHEN INSTALLING THEM INTO EXISTING PRESTRESSED CONCRETE S-4 EQUIPMENT:RACKING-ENGINEERING LETTER TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION.EXERCISE EXTREME CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION.MAINTAIN A nth t nn st th S-5 EQUIPMENT:RACKING-ENGINEERING LETTER tt St MINIMUM CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR. S-6 EQUIPMENT:RACKING-CERTIFICATION&REPORT 25.THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. REVISION 26.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC 300.6 01, 310.8 D) DATE DESCRIPTION 27.GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM.(NEC 250.97) 28.THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF SMALLER THAN#6 COPPER WIRE.(NEC 250.64 B) s• 29.GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT _ _ BUSBARS WITHIN LISTED EQUIPMENT.(NEC 250.64 C) - 30.RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END.(CEC -® 12th.St OO 12th CITY OF ANACORTES 250.64(E) 31.WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, o A SIGN WILL BE PROVIDED WARNING OF THE HAZARD PER NEC 690.17.34.EACH UNGROUNDED PLANNING AND BUILDING D E PT•• DATE CONDUCTOR OF THE MULT-IWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PER PHASE AND SYSTEM PER I 5/1 4/21 NEC270.5. I DRAWN: 32.CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC25O.97&250.92(B)&LAMC 93.250.97. APPROVED PLANS SHEET TITLE 33.DC CONDUCTORS EITHER DO NOT ENTER THE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER NEC 690.31(E).LAMC 93.690.31(E) VICINITY MAP REVIEWED FOR CODE COMPLIANCE GENERAL 34.ALL METALLIC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS(CONDUIT, D_ 0 1_0 `�-^ JUNCTION&PULL BOXES,RACEWAY,ETC)SHALL BE SOLIDLY GROUNDED PER THE MANUFACTURER'S PERMIT#: NOTES 3 INSTALLATION INSTRUCTIONS LAMC 93.690.1 10.3&93.1 10.3(B). 35.SCREWS,NUTS,BOLTS&WASHERS THAT ATTACH EQUIPMENT GROUNDING LUGS SHALL BE ADDRESS: 2005 10TH ST STAINLESS STEEL LAMC 93.110.3(B). / PROJECT DATA 36.NO PIPING,DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE APPROVED BY: ��'� V - LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. 37.ALL FIELD INSTALLED JUNCTION,PULL AND OUTLET BOXED LOCATED BEHIND MODULES OR PANELS SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE($)OR PANEL(S)SECURED BY SUBJECT TO FIELD INSPECTION. APPROVED PL S SHALL NOT SHEET NUMBER REMOVABLE FASTENERS. 38.REMOVAL OFA DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BE ALTERED WITHOUT AUTHORIZA ON. BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. 39.THE ROOF MOUNTED PHOTOVOLTAIC MODULES,PANELS,OR SOLAR VOLTAIC ROLL ROOFING A ., MATERIAL SHALL HAVE THE SAME OR BETTER LISTED FIRE-RESISTANCE RATING THAN THE BUILDING ROOF COVERING MATERIAL. 40.ALL ROOF MOUNTED CONDUIT WILL BE A MINIMUM 1/2"OFF THE ROOF SURFACE. J c LEGEND 13 (E) EXISTING (N) NEW --- WIRING METHOCo, • • • •AP FIRE ACCESS P6 ' I,0 infinity solar { (N) Roof Mounted PV Array JB JUNC I&N BOX 0 9 DM TIL E- rr, 14 x STP310S-20/Wfb Suntech Modules / INFINITY HOME SOLUTIONS I MSP I MAN- - .� + L 4 x Hoymiles Microinverters 6405 E MILL PLAIN I SP I sup `it, 1891 -C�r� , . VANCOUVER,WA 98661 IACDh Ac.�,1 G 6c$� `o PHONE: 1-800-818-0598 IINvI INVE +1V F+ER -,_, - EMT Conduit Run on Roof 6-"-3Z" Above ICPI SOLAR COMBINER PANEL Rooftop) or Inside Attic Where Possible IBATI BATTERY IB P I BACKED-UP PANEL (N) Supplemental AC Disconnect (Inside) (E) Main Service Panel (Inside) (E) Utility Meter PROJECT DETAILS (N) Customer Generation AC Disconnect 4.340 DC KW (Outside) 4.800 KW CEC-AC RATING MICROINVERTER SYSTEM 8 5° 9O° (N) Solar Combiner Panel (Outside) I—I a TILT AZIMUTH CUSTOMER INFO 1 1 2005 10TH ST ANACORTES, C P ACDil MSP ACID]UM WA 98221 TOM FLANAGAN REVISION 1 OTH ST DATE DESCRIPTION LLI DATE 5/14/21 DRAWN: — d SHEET TITLE Li. L.; g—it SITE PLAN SITE ,o SCALE: 1/8"= 1' PLAN SHEET NUMBER VICINITY A 1_4 2 ,1, SCALE: 1/64" = 1' r 0 1.vjit.CODE co -6 infinity s01 a r �� j AG � rn INFINITY HOME SOLUTIONS Y 6405 E MILL PLAIN � 1891 C�r� VANCOUVER,WA 98661 PHONE: 1-800-818-0598 �tO FIELD v.`" j Pathway !l !I I rIi ; PROJECT DETAILS 4.340DC KW ' 4.800 KW CEC-AC RATING ' MICROINVERTER SYSTEM 5° 90° e CO TILT AZIMUTH 8 N CUSTOMER INFO TIl !E` M 2005 10TH ST 111.21211' N ANACORTES, Il�i� !, WA 98221 C P ACD1 ® MSP ACM Il !i !l !I TOM FLANAGAN 1 101;1 !I II Il REVISION DATE DESCRIPTION / j m m DATE 5/14/21 / A m MOUNTING CALCULATIONSDRAWN: SHEET TITLE A MOUNTING SYSTEM AND MANUFACTURER IRONRIDGE RACKING WITH NANOMOUNT B TOTAL WEIGHT OF MODULES AND RACKING 668 LBS WIRING & WIRING & MOUNTING PLAN MODULE WEIGHTXNUMBEROFMODULES 40.3LBS X#MODULES 564 LBS MOUNTING ,1, SCALE: 1/8"= 1' RACKING WEIGHT 103 PLAN C TOTAL NUMBER OF ATTACHMENTS POINTS 42 IMI Circuit 1 / 2 Microinverters with 7 Modules D TOTAL NUMBER OF MODULES 14 SHEET NUMBER Circuit 2 / 2 Microinverters with 7 Modules E WEIGHT PER ATTACHMENT POINT(B/C) -NOTEXCEED45LBS 1 15.9 LBS MAXIMUM SPACING BETWEEN POINTS ON A FRAMING MEMBER SPACING F 48„ RAIL IS 24"ON CENTER G TOTAL SURFACE AREA OF PV MODULES 17.65 SQFT X#MODULES 247 SO FT A - 3 DISTRIBUTED WEIGHT OF PV MODULE ON H TOTAL WEIGHT/MOD SQ FT 2.7 PSF • I ROOF(B/F) C 1 6 �QFOR CODE0O �'�4 GAIY O {, infinitycolar •es' 2 (E) 125A RATED MSP (E)UTILITY METER M 240V,3W, 1-PHASE 240V,3W, 1-PHASE INFINITY HOME SOLUTIONS POINT OF CONNECTION SOUTH EXTERIOR WALL 6405 E MILL PLAIN (N) S-20/WFB 310W LOCATED:INSIDE TO UTILITY A 6��� qC�) - �1 200NES SUP.FUSIBLE AC GRID VANCOUVER,1-800-818-0598 WA 98661 N (N)60A (N)60A PHONE: NON-FUSIBLE AC DISCONNECT HOW, . g 01 CROINVERTER (N) 1 25A RATED DISCONNECT LOCATED.INSIDE SUPPLY SIDE CONNECTION (E)125A BRANCH 1-7 MODULES WITH 2 MICROINVERTERS COMBINER PANEL LINE TAP Th 240V,3W, 1-PHASE LINE LINE ILSCO • (1") LOCATED:OUTSIDE (N)JB • N (k NEMA 3R T C' ici) 25A E ^- - N /V �� �. LOAD LOAD -�� ��- (N)15A P-- --- G ---�---- G --- .---I ,---, �� I n ^ v \ i V ,1/4 i -v - - BRANCH 2-7 MODULES WITH 2 MICROINVERTERS -I (N)1 5A VISIBLE,LOCKABLE VISIBLE,LOCKABLE -�\ ,--`- CONNECT NEW SOLAR CIRCUIT TO I EXTERNALLY OPERABLE EXTERNALLY OPERABLE _'' '' EXISTING ELECTRICAL SYSTEM VIA I4W.1 I I11111' - I - 6OA RATED 25A FUSES:6OA RATED •-• - --, --� •-• I 240V,NEMA3R 240V,NEMA3R �\ \ LINE SIDE TAP; 4 144 •..1 4 L_ ____� __J ULLISTED ULLISTED LOAD SIDE OF NET METER AND DA R-i R-i -0 D-i i \ / \ -- DG222URB DG222NRB SUPPLY SIDE OF MSD CODE 705.12(A),230.82(6), I I L G 690.13(C)&690.15 PROJECT DETAILS J WITH INTEGRATED (E)EARTH 4.340 DC KW AUTOMATIC RAPID - GROUND SHUTDOWN UPON AC GRID 4.800 KW CEC-AC RATING VOLTAGE LOSS MICROINVERTER SYSTEM 5° 90° TILT AZIMUTH CUSTOMER INFO 2005 1 OTH ST ANACORTES, WA 98221 TOM FLANAGAN NOTES TO ELECTRICIAN CUSTOMER GENERATION DISCONNECT WITHIN 10FT OF THE UTILITY METER. NO SPARE SPACE FOR BACK FEED BREAKER.SOLAR INTERCONNECTION REVISION WITH A LINE SIDE CONNECTION(LINE TAP). INSTALL FUSE REDUCERS TO ACCEPT THE 25A FUSES. NEC 705.1 2(D)(2)(3)(B) DATE DESCRIPTION WHERE TWO SOURCES,ONE A UTILITY AND THE OTHER AN INVERTER,ARE _ LOCATED AT OPPOSITE ENDS OF A MICROINVERTER MAX AC OUTPUT BUSBAR THAT CONTAINS LOADS,THE MAX AC MAX AC SUM OF 125%OF THE INVERTER(S) TYPE OR MICROINVERTER OUTPUT OUTPUT OUTPUT CIRCUIT CURRENT AND THE MICROINVERTER (#) (AMPS) (AMPS) RATING OF THE OVERCURRENT DEVICE ' HM-300N 0 1.23 0.00 PROTECTING THE BUSBAR SHALL NOT EXCEED 1 20%OF THE AMPACITY OF THE DATE HM-600N 0 2.46 0.00 BUSBAR. 5/14/21 DRAWN: HM-1200N 4 5.00 20.00 SUM 20.00 SHEET TITLE WIRE/CONDUIT SCHEDULE &VOLTAGE DROP CALCULATIONS 125%OF MICROINVERTERS MAX AC OUTPUT LENGTH VOLTAGE SUM ELECTRICAL MAX AC 125% RESULT OCPD SIZE TAG DESCRIPTION CONDUIT(SIZE/TYPE) CONDUCTOR(TYPE/SIZE/QUANTITY) (FT-MAX) DROP(%) VDROP(%) SINGLE OUTPUT(AMPS) (AMPS) 20.00 1.25 25.00 25A MODULE TO MICROINVERTER FREE AIR (2)#12 AWG PV WIRE&# 10 AWG SOLID COPPER(G) 6 0.67 0.67 SERVICE LOAD CALCULATIONS NOTE:SUM OF DC VDRP(%)MUST BE LESS THAN 2% 2%>0.67%=OK LINE DIAGRAM BACKFED 120%RULE-PER 705.12(D)(2)(3)(B) A MICROINVERTER TO JUNCTION BOX FREE AIR-CABLE (2)# 10 AWG(L 1&L2)&(1)#1 0 AWG(G)PER BRANCH 10 0.10 BUS RATING SIZE MUTIPLIER(120%) RESULT SHEET NUMBER B JUNCTION BOX TO COMBINER PANEL 3/4"EMT OR PVC (4)# 1 O AWG THHN-2(L I &L2)&(I)#8 AWG THHN-2(G) 50 0.52 125 1.20 150 -- - 0.78 MAIN BREAKER SIZE INVERTER+125% RESULT C COMBINER PANEL TO AC DISCONNECT 3/4"EMT OR PVC (2)#6 AWG THHN-2(L I,L2)&(1)#6 AWG THHN-2(G) 5 0.04 125 25.00 150.00 D&E AC DISCONNECT TO INTERCONNECTION 3/4"EMT OR PVC (2)#6 AWG THHN-2(L I,L2)&(1)#6 AWG THHN-2(G) 15 0.12 E . 1 150A>/=150A=OK - NOTE:SUM OF AC VDRP(%)MUST BE LESS THAN 2% 2%>0.78%=OK .1 c 1 MAXIMUM SYSTEM DC VOLTAGE MODULE VOC(NEC 690.7 AND 690.1 1) [7)1 A MICROINVERTER MAKE AND MODEL# HOYMILES HM-1200N&HM-600N&HM-400N HOYMILES MAXIMUM INPUT VOLTAGE 60 VOLTS (FROM MICROINVERTER SPECIFICATIONS) 401Z CODE co SUNTECH Voc TEMPERATURE CORRECTION -0.304 %/°C (FROM MODULE SPECIFICATIONS) infinity solar T-1'L ,ECIFICATION LOW TEMP(°C) -8 °C (FROM CLIMATIC DATA) �L DELTA TEMP(°C) 33 °C (FROM STC) MANUFACTW R� lot. 2 SUNTECH SUNTECH MODULE Voc 40.2 VOLTS (FROM MODULE SPECIFICATIONS) MODEL NO' M STP310S-20/WFB #OF MODULES IN SERIES 1 INFINITY HOME SOLUTIONS PEAK POWER 1111W11111 310W B TEMPERATURE CORRECTED Voc 44.23 VOLTS MODULE VOC X #OF MODULES IN SERIES X Voc CORRECTION FACTOR 6405 E MILL PLAIN RATED VOLTS, :+. 1891 �y 33.1 V NOTE:"A"MUST BE LARGER THAN"B" 60V >44.2V=OK THE VALUE CALCULATED MUST BE LESS THAN MICROINVERTERS MAX DC INPUT VOLTAGE VANCOUVER,WA 98661 RATED CURRY Ogt `� 9.37 A DC CONDUCTOR AMPACITY CALCULATION PHONE: 1 800 818 0598 OPEN CIRCUIT V I (0' 40.2 V MODULE TO MICROINVERTER(NEC ART 310.15) EXPECTED WIRE TEMPERATURE(FREE AIR) 37 °C SHORT CIRCUIT CURRENT(Isc) 9.87 A ADD 22°C OR 40°F FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOF 59 °C MICROINVERTERS SPECIFICATION TEMPERATURE CORRECTION FACTOR 0.71 NEC TABLE 310.15(B)(2)(A) #OF CURRENT CARRYING CONDUCTORS 2 FREE AIR MICROINVERTER MAKE HOYMILES .80(FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00(FOR 3 OR LESS CONDUCTORS IN CONDUIT) CONDUIT FILL CORRECTION 1.00 NEC TABLE 310.15(B)(3)(A) MICROINVERTER MODEL NO. HM-1 200N CIRCUIT CONDUCTOR SIZE #12 AWG MAXIMUM AC OUTPUT 1,200 W CIRCUIT CONDUCTOR AMPACITY 30 AMPS NEC TABLE 310.15(B)(16) MAX INPUT VOLTAGE 60 V SUNTECH MODULE Isc 9.87 AMPS (FROM MODULE SPECIFICATIONS) MAX AC CURRENT 5.00 A SUNTECH Isc TEMPERATURE CORRECTION 0.05 %/°C (FROM MODULE SPECIFICATIONS) MICROINVERTER MODEL NO. HM-600N A REQUIRED CIRCUIT CONDUCTOR AMPACITY 15.49 AMPS REQUIRED CIRCUIT CONDUCTOR AMPACITY= 1.56 x TEMPERATURE CORRECTED Isc(AMPS)(FROM MODULE SPECIFICATIONS) MAXIMUM AC OUTPUT 600 W B DERATED AMPACITY OF CIRCUIT CONDUCTOR 21.30 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY NEC TABLE 310.15(B)(2)(A) MAX INPUT VOLTAGE 60 V NOTE:"B"MUST BE LARGER THAN"A" 21.3A > 1 5.5A=OK MAX AC CURRENT 2.46 A AC CONDUCTOR AMPACITY CALCULATION PROJECT DETAILS MICROINVERTER MODEL NO. HM-300N MICROINVERTERS TO JUNCTION BOX 4.340 DC KW MAXIMUM AC OUTPUT 300W AMBIENT TEMPERATURE ADJUSTMENT MAX INPUT VOLTAGE 60 V EXPOSED CONDUIT 37 °C 4.800 KW CEC-AC RATING MICROINVERTER SYSTEM MAX AC CURRENT 1.23 A TEMPERATURE CORRECTION FACTOR 0.91 NEC TABLE 310.15(B)(2)(A) #OF CURRENT CARRYING CONDUCTORS 2 IN FREE AIR 5° 90° .80(FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00(FOR 3 OR LESS CONDUCTORS IN CONDUIT) CONDUIT FILL CORRECTION 1.00 TILT AZIMUTH NEC TABLE 310.15(B)(3)(A) CIRCUIT CONDUCTOR SIZE #10 AWG CUSTOMER INFO CIRCUIT CONDUCTOR AMPACITY @ 90° 40 AMPS NEC TABLE 310.15(B)(16) 2005 1 OTH ST INVERTER'S MAXIMUM AC OUTPUT CURRENT 10.00 AMPS MICROINVERTER MANUFACTURER SPECIFICATIONS ANACORTES, A REQUIRED AC CONDUCTOR AMPACITY 12.50 AMPS REQUIRED AC CONDUCTOR AMPACITY=1.25 X MAXIMUM MICROINVERTERS OUTPUT CURRENT(AMPS) WA 98221 B DERATED AMPACITY OF CIRCUIT CONDUCTORS 36.40 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY NEC TABLE 310.15(B)(2)(A) TOM FLANAGAN NOTE:"B"MUST BE GREATER THAN"A" 36.4A > 1 2.5A=OK AC CONDUCTOR AMPACITY CALCULATION JUNCTION BOX TO COMBINER PANEL AMBIENT TEMPERATURE ADJUSTMENT EXPOSED CONDUIT 37 °C TEMPERATURE CORRECTION FACTOR 0.91 NEC TABLE 310.15(B)(2)(A) #OF CURRENT CARRYING CONDUCTORS 4 REVISION CONDUIT FILL CORRECTION 0.80 .80(FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00(FOR 3 OR LESS CONDUCTORS IN CONDUIT) NEC TABLE 310.15(B)(3)(A) DATE DESCRIPTION CIRCUIT CONDUCTOR SIZE #10 AWG CIRCUIT CONDUCTOR AMPACITY @ 90° 40 AMPS NEC TABLE 310.15(B)(16) INVERTER'S MAXIMUM AC OUTPUT CURRENT 10.00 AMPS MICROINVERTER MANUFACTURER SPECIFICATIONS A REQUIRED AC CONDUCTOR AMPACITY 12.50 AMPS REQUIRED AC CONDUCTOR AMPACITY=1.25 X MAXIMUM MICROINVERTERS OUTPUT CURRENT(AMPS) B DERATED AMPACITY OF CIRCUIT CONDUCTORS 29.12 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY NEC TABLE 310.15(B)(2)(A) NOTE:"B"MUST BE GREATER THAN"A" 29.1 A > 1 2.5A= OK DATE 5/14/21 AC CONDUCTOR AMPACITY CALCULATION DRAWN: COMBINER PANEL TO INTERCONNECTION SHEET TITLE 1 AMBIENT TEMPERATURE ADJUSTMENT 37 °C EXPOSED CONDUIT ELECTRICAL TEMPERATURE CORRECTION FACTOR 0.91 NEC TABLE 310.15(B)(2)(A) #OF CURRENT CARRYING CONDUCTORS 2 CALCULATIONS CONDUIT FILL CORRECTION 1.00 .80(FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00(FOR 3 OR LESS CONDUCTORS IN CONDUIT) NEC TABLE 310.15(B)(3)(A) CIRCUIT CONDUCTOR SIZE #6 AWG CIRCUIT CONDUCTOR AMPACITY @ 90° 75 AMPS NEC TABLE 310.15(B)(16) SHEET NUMBER INVERTER'S MAXIMUM AC OUTPUT CURRENT 20.00 AMPS MICROINVERTER MANUFACTURER SPECIFICATIONS A REQUIRED AC CONDUCTOR AMPACITY 25.00 AMPS REQUIRED AC CONDUCTOR AMPACITY=1.25 X MAXIMUM MICROINVERTERS OUTPUT CURRENT(AMPS) B DERATED AMPACITY OF CIRCUIT CONDUCTORS 68.25 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITYE .1 2 NEC TABLE 310.15(B)(2)(A) NOTE:"B"MUST BE GREATER THAN"A" 68.2A >25.OA=OK \ i NET METER 0 UTILITY/AHJ(PHENOLIC) ! WAIVING DUAL POVs-RSOURCE POWER TO THIS BUILDING IS SUPPLIED FROM THE infinitysolor SECOND U CA1 14 AI Kt c1,C SYSTEM INFINITY HOME SOLUTIONS FOLLOWING SOURCES WITH DISCONNECT LOCATED AS SHOWN 6405 E MILL PLAIN Allillat, 1891 VANCOUVER,WA 98661 G e^: il�w � L PHONE: 1-800-818-0598 PHrTO ' L AICAC DISCONNECT TURN OFF PHOTOVOLTAIC NET METER AC DISCONNECT PRIOR TO '1■11 In WORKING INSIDE PANEL W C DISCONNECT •■II •U ii NEC 110.21(B)&NEC 705.12 NEC 690.13(B) m117■ •■117■ •■a■ ! WARNING DUAL POWER SOURCE MIN ; SECOND SOURCE IS PHOTOVOLTAIC SYSTEM \ 1Ciz) A WARNING NEC 705.12(B)(3) og SUPPLY SIDE TAP INVERTER OUTPUT CONNECTION.DO NOT RELOCATE AS REQUIRED IF PV PROJECT DETAILS THIS OVERCURRENT INTERCONNECTION IS S 4.340 DC KW • DEVICE. MADE TO SUPPLY SIDE OF NEC 705.12(B)(2)(3)(b) SERVICE DISCONNECT 4.800 KW CEC-AC RATING MICROINVERTER SYSTEM 5° 90° TILT AZIMUTH SOLAR PV SYSTEM EQUIPPED SERVICED BY QUALIFIED PERSONNEL ONLY WITH RAPID SHUTDOWN °• CUSTOMER INFO • - 1 ,77o. p 2005 1 OTH ST TURN RAPID SHUTDOWN ANACORTES, SWITCH TO THE "OFF"POSITION TO �� M��,,, �„.,.� WA 9822 1 SHUTDOWN PV SYSTEM AND REDUCEall TOM FLANAGAN SHOCK HAZARD IN THE ARRAY RAPID SHUTDOWN I SWITCH FOR NEC 690.56(C)(1)(a) SOLARPVSYSTEM NEC 690.56 PHOTOVOLTAIC AC DISCONNECT PHOTOVOLTAIC SYSTEM MAXIMUM AC OPERATING CURRENT 20.0 A COMBINER PANEL MAXIMUM AC OPERATING VOLTAGE 240 VAC ADHESIVE FASTENED SIGNS: NEC 690.54 DO NOT ADD LOADS •THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. REVISION •WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL FIELD APPLIED LABELS,WARNINGS, DATE DESCRIPTION NEC 690.31 G 3 & 4 AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4[NEC 1 10.21(B)FIELD MARKING]. •ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED.VINYL SIGNS WARNING WARNING: PHOTOVOLTAIC SHALL BE WEATHER RESISTANT[IFC 605.1 1.1.3] ELECTRIC SHOCK HAZARD POWER SOURCE DO NOT TOUCH TERMINALS 7■117■11 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS TERMINALS ON BOTH LINE AND ;�■I1:1.1 APPLICATION. LOAD SIDES MAY BE ENERGIZED 3■117■II IN THE OPEN POSITION M1;M 2.) ALL CONDUCTORS SHALL BE COPPER,RATED FOR 600 V AND 90 DEGREE C WET 7EI,17mI,1 ENVIRONMENT. DATE 5/14/21 NEC 690.13(B)&NEC 690.115(D) 3.) WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DRAWN: , DIRECTLY TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE,HIP, SHEET TITLE OR VALLEY. RAPID SHUTDOWN 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SWITCH FOR SHALL COMPLY WITH NEC 1 10.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR LABELING SOLAR PV SYSTEM SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. REQUIREMENT NEC 690.56(C)(3) WARNING: PHOTOVOLTAIC 6.) WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. POWER SOURCE 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND SHEET NUMBER NEC 690.31(G)(3)&(4) MODULE SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. SYSTEM DC CIRCUIT CONDUCTORS.EXPOSED RACEWAYS,CABLE TRAYS&OTHER WIRING 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB METHODS.COVERSIOR ENCLOSURES THE AV IL PULL BOXES&OPENINGS BOXES.CONDUIT BODIES IN WHICH ANY OF THE AVAILABLE CONDUIT OPENINGS ARE UNUSED. LUG OR ILSCO GBL-4DBT LAY-IN LUG. LABELS OR MARKINGS SHALL BE VISIBLE AFTER INSTALLATION.REFLECTIVE WITH )i"UPPERCASE, 1O.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE E - 3 3 WHITE ON RED.EVERY SECTION OF THE WIRING SYSTEM SEPARATED BY ENCLOSURES,WALLS, PARTITIONS,CEILINGS,OR FLOORS.SPACING BETWEEN LABELS OR MARKINGS SHALL NOT BE MORE THAN 10' J I 1 SI UM III. illillliMil infinitysolar Hy° o ' ° 105 -20/Wfb J SUNTECH HyPro STP310S - 20/Wfb N SUNTECH INFINITY HOME SOLUTIONS i1►z P; 05S - 20/Wfb STP3OSS - 20/Wfb 6405 E MILL PLAIN - + 1891 r` 00S - 20/Wfb STP300S - 20/Wfb PHONE: 1 80 81A8 0598 1 •,<,cTT`IC 0)1Ns"Rv Electrical Characteristics 310 Watt STC STP3105-20/ STP305S-20/ STP300S-20/ 992139.1]810.081 Wfb Wfb Wfb MONOCRYSTALLINE SOLAR MODULE ° ° d� 942137.11:110.041 Maximum Power at STC(Pmax) 310W 305 W 300 W !"� �" Optimum Operating Voltage(Vmp) 33.1 V 32,8 V 32.5 V 8-051100A �n�d bin Features �° Optimum Operating Current(Imp) 9.37 A 9.30 A 9.23 A 8-141,91053,0351 mountings. Berne Open Circuit Voltage(Voc) 40.2 V 39.8 V 39.6 V 4;� High module conversion �III� PID resistant Short Circuit Current(Isc) 9.87 A 9.80 A 9.72 A efficiency L-I r-I Advanced cell technology o Module efficiency up to PID and qualified materials lead to Module Efficiency 18.9% 18.6% 18.3% 18.9/0 18.9o%achieved through ae'I"�"` high resistance to PID _ _ _r-i Operating Module Temperature -40°C to+85°C advanced cell technology and A F -IA Maximum System Voltage 1000V DC(UL) manufacturing capabilities (Back View) _ Section A-A Maximum Series Fuse Rating 20 A _ uJ Power Tolerance 0/+5W Positive tolerance p © Suntech current sorting oX lir ,IIIIII �, TSoleancesofe 1000Pmaz Woc an msdare aem within re 25+/-56.AM=1.5; .1111 Positive tolerance of up to p © process " oleran<e<°fpmax,v«a"di are all w nm./-s9 0/+5w 5W delivers higher outputs 2% System output maximized by � 4,s1 III III reliablity reducing mismatch losses up (Frontview) PROJECT DETAILS •IIIIII IIIII_ tit_ NMOT STP3105-20/ STP305S-20/ STP3005-20/ to 2%with modules sorted& Note:mm[inch) l wfb Wfb �I Wfb im packaged by amperage Maximum Power at NMOT(Pmax) 232.6 W 228.3 W 225.0 W 4.340 DC KW 1 Extended load tests Withstanding harsh Optimum Operating Voltage(Vmp) 30.8 V 30.5 V 30.3 V 4.800 KW CEC-AC RATING J r` Module certified to withstand ® environment Optimum Operating Current(Imp) 7.55 A 7.49 A 7.43 A MICROINVERTER SYSTEM front side maximum static Reliable quality leads to a Open Circuit Voltage(Voc) 37.6V 37.1 V 37.0 V 5 90 5440 a test load(5400 Pascal)and a"°""""1e"' better sustainability even in Current-Voltage&Power-Voltage Curve(3105) Short Circuit Current(Isc) 7.97 A 7.92 A 7.85 A TILT AZIMUTH rear side maximum static test harsh environment like desert, ,2 3m NMOT Irradiance 800 W/m',ambient temperature 20°C,AM=1.5,wind speed 1 m/s, loads(3800 Pascal)* farm and coastline CUSTOMER INFOCer300 ** Ala E. Temperature Characteristics 2005 7 OTH ST IEC 611ficati, standards: CIP° 7 us - ` C Mrs �e� Nominal Module Operating Temperature(NMOT) 42t2°C1.0 ANACORTES, IEC 61215,IEC61730,conformity to CE `` / g ass€ Temperature Coefficient of Pmax -0.37%PC WA 98221 a 150 s Temperature Coefficient of Voc -0.304%/°C Trust Suntech to Deliver Reliable Performance Over Time Special 5 busbar design 1 °°6 Temperature Coefficient of lsc 0.050%/°C TOM FLANAGAN •World-class manufacturer of crystalline silicon photovoltaic modules The uniquecelldesign leads L •Unrivaled manufacturing capacity and world-class technology reduction in electrodes p •Rigorous quality control meeting the highest international standards: resistance,shading area and l Mechanical Characteristics raise in conversion efficiency. n p 0 m Solar Cell Monocrystalline 9001:2008,ISO 14001:2004 and IS017025:2005 silicon 6 inches Residual stress distribution can v"mge(v) •Regular independently checked production process from international No.of Cells 60(6 x 10) accredited institute/company be more even,reducing the . ...,mnwro=mow,-mnw,m-,mw,m=mnw,s micro cracks risks. Dimensions 1650 x 992 x 35mm(65.0 x 39.1 x 1.4 inches) •Tested for harsh environments(salt mist,ammonia corrosion and sand Weight 18.3 kgs(40.3lbs.) REVISION blowing testing:IEC 61701,IEC 62716,DIN EN 60068-2-68)*** Front Glass 3.2 min(0.13 inches)tempered glass •Long-term reliability tests DATE DESCRIPTION •2 x 100%EL inspection ensuring defect-free modules Frame Anodized aluminium alloy Industry-leading Warranty based on nominal power IP68 Rated Junction Box Dealer information Junction Box IP68 rated(3 bypass diodes) _ Output Cables 4.0 mm2(0.006 inches'),symmetrical lengths(-)1000mm(39.4 •97.5%in the first year,thereafter,for The Suntech IP68 rated inches)and(+)1000 mm(39.4 inches) years two(2)through twenty-five junction box ensures an Connectors MC4 compatible (25),0.7%maximum decrease from outstanding waterproof /ndustry[jjj1rwarrenr MODULE's nominal power output *IR) level,supports installations 1"▪ m_ Y i the25thyeaafteh the defined reduces stress onthecables. Packing Configuration DRAWN: the 80.7% in all orientations 5/14/21 WARRANTY STARTING DATE**** High reliable performance, Container 20'GP 40'HC SHEET TITLE 1 10 25.12-year product warranty low resistance connectors Pieces per pallet 30 30 •25-year linear performance ensure maximum output Pallets per container 6 28 warranty for the highest energy MODULE d O DUL�E f I I production. Pieces per container 180 840 Information on how to install and operate this product is available in the installation instruction.All values indicated in this data sheet are subject to change without prior announcement.The specifications may vary sightly.Ali specifications are in DATA SHEET accordancew,,h standard EN 50380.Color differences of the modules relative to the figures as well as discoloration of/in the modules which do not impair their proper functioning are possible and do not constitute a deviation from the specification. *Please refer to Suntech Standard Module Installation Manual for details. **WEEE only for EU market. ***Please refer to Suntech Product Near-coast Installation Manual for details. ...Please refer to Suntech Product Warranty for details. SHEET NUMBER ©Copyright 2019 Suntech Power www.suntech-power.com UL-STP-Wfb-NO2.01-Rev 2019 °Copyright 2019 Suntech Power www.suntech-power.com • UL-STP-Wfb-NO2.01-Rev 2019 E - 4 c ..\ �OFOR CODEC,O g � Y odiA{� , infinity olar 4 ‘ 1 lies Leading Solar Energy by a Trustable Way ho miles Leading Solar Energy by a Trustable Way INFINITY HOME SOLUTIONS y 6405E MILL PLAIN G Y 891 �� VANCOUVER,WA 98661 o PHONE: 1-800-818-0598 70>,rEW>,h�e Model MI-600N MI-700N MI-800N Model MI-300N MI-350N MI-400N - Input Data (DC) Input Data (DC) Commonly used module power(W) 240-380 280-440 320-500 Commonly used module power(W) 240-380 280-440 320-500 Module compatibility 60-cell or 72-cell PV modules 60-cell or 72-cell PV modules 60-cell or 72-cell PV modules Module compatibility 60-cell or 72-cell PV modules 60-cell or 72-cell PV modules 60-cell or 72-cell PV modules Peak power MPPT voltage range(V) 29-48 33-48 34-48 Peak power MPPT voltage range(V) 29-48 33-48 34-48 Start-up voltage(V) 22 22 22 Start-up voltage(V) 22 22 22 Operating voltage range(V) 16-60 16-60 16-60 Operating voltage range(V) 16-60 16-60 16-60 Maximum input voltage(V) 60 60 60 Maximum input voltage(V) 60 60 60 Maximum input current(A) 11.5 11.5 12.5 Maximum input current(A) 2*11.5 2*11.5 2*12.5 PROJECT DETAILS Output Data (AC) Output Data (AC) 4.340 DC KW Peak output power(W) 300 350 400 Peak output power(W) 600 700 800 4.800 KW CEC-AC RATING Maximum continuous output power(W) 295 349 382 Maximum continuous output power(W) 590 696 766 MICROINVERTER SYSTEM Maximum continuous output current(A) 1.23 1.42 1.45 1.68 1.59 1.84 Maximum continuous output current(A) 2.46 2.84 2.9 3.35 3.19 3.68 50 90° Nominal output voltage/range(V) 240/211-264 208V/183-228 240/211-264 208V/183-228 240/211-264 208V/183-228 Nominal output voltage/range(V) 240/211-264' 208/183-228' 240/211-264' 208/183-228' 240/211-264' 208/183-228' TILT AZIMUTH Nominal frequency/range(Hz) 60/55-65' 60/55-65' 60/55-65' Nominal frequency/range(Hz) 60/55-65' 60/55-65' 60/55-65' CUSTOMER INFO Power factor >0.99 >0.99 >0.99 Power factor >0.99 >0.99 >0.99 2005 10TH ST Total harmonic distortion <3% <3% <3% Total harmonic distortion <3% <3% <3% ANACORTES, Maximum units per branch2 13 11 11 9 10 8 Maximum units per branch' 6 5 5 4 5 4 WA 9822 1 Efficiency Efficiency CEC peak efficiency 96.70% TOM FLANAGAN CEC peak efficiency 96.70% 96.70% 96.70% CEC weighted efficiency 96.50% CEC weighted efficiency 96.50% 96.50% 96.50% Nominal MPPT efficiency 99.80% Nominal MPPT efficiency 99.80% 99.80% 99.80% Nighttime power consumption(mW) <50 Nighttime power consumption(mW) <50 <50 <50 Mechanical Data Ambient temperature range(°C) -40-*65 Mechanical Data Dimensions(WxHxD mm) 178 x 153 x 28 Ambient temperature range(°C) -40-+65 REVISION Weight(kG) 1.98 Dimensions(WxHxD mm) 250 x 170 x 28 DATE DESCRIPTION Enclosure rating outdoor-NEMA(IP67) Weight(kG) 3.0(including 2.42m AC cable) Cooling Natural convection-No fans Enclosure rating Outdoor-NEMA(IP67) Features Cooling Natural convection-No fans Communication 2-4GHz Proprietary RF(Nordic) Features Monitoring Hoymiles Monitoring System Communication 2.4GHz Proprietary RF(Nordic) DATE 5/14/21 Warranty Up to 25 years Monitoring Hoymiles Monitoring System DRAWN: Compliance UL1741,IEEE1547,CSA C22.2 No.107.1-16,FCC 15B,FCC 15C Warranty Up to 25 years SHEET TITLE PV Rapid Shutdown Conforms with NEC-2014 and NEC-2017 Article 690.12 and CEC-2018 Sec 64-218 Rapid Shutdown of PV Systems Compliance UL1741,IEEE1547,CSA C22.2 No.107.1-16,FCC 15B,FCC 15C PV Rapid Shutdown Conforms with NEC-2014 and NEC-2017 Article 690.12 and CEC-2018 Sec 64-218 Rapid Shutdown of PV Systems MICROINVERTER *1 Nominal voltage/frequency range can be changed due to the requirements of local power department. DATA SHEET *2 Refer to local requirements for exact number of microinverters per branch. *1 Nominal voltage/frequency range can be changed due to the requirements of local power department. *2 Refer to local requirements for exact number of microinverters per branch. SHEET NUMBER . r 1 6 FOR CODS co A{ infinity solar [ / j *. - riles The World's Safest solar solution for you and your family INFINITY HOME SOLUTIONS 6405E MILL PLAIN Yr a91 �� VANCOUVER,WA 98661 o PHONE: 1-800-818-0598 C7 -ev j� EL FID\ Model HM-1000N HM-1200N HM-1500N Input Data (DC) Commonly used module power(W) 200-310 240-380 300-470 Module compatibility 60-cell or 72-cell PV modules 60-cell or 72-cell PV modules 60-cell or 72-cell PV modules Peak power MPPT voltage range(V) 27-48 29-48 36-48 Start-up voltage(V) 22 22 22 Operating voltage range(V) 16-60 16-60 16-60 Maximum input voltage(V) 60 60 60 Maximum input current(A) 4*10.5 4*11.5 4*11.5 Output Data (AC) PROJECT DETAILS Peak output power(VA) 1000 1260 1200 1500 1350 Maximum continuous output power (VA) 958 1200 1109 1438 1246 4.340 DC KW Maximum continuous output current(A) 3.99 4.61 5 5.33 5.99 5.99 4.800 kW CEC-AC RATING MICROINVERTER SYSTEM Nominal output voltage/range(V) 240/211-264' 208/183-228' 240/211-264' 208/183-228' 240/211-264' 208/183-2281 5° 90° Nominal frequency/range(Hz) 60/55-65' 60/55-65' 60/55-65' TILT AZIMUTH >0.99 default >0.99 default >0.99 default CUSTOMER INFO Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging 0.85 leading...0.85 lagging Total harmonic distortion <3% <3% <3% 2005 7 OTH ST Maximum units per branch 2 4 3 3 3 2 2 ANACORTES, WA 98221 Efficiency CEC peak efficiency 96.70% 96.70% 96.70% TOM FLANAGAN CEC weighted efficiency 96.50% 96.50% 96.50% Nominal MPPT efficiency 99.80% 99.80% 99.80% Nighttime power consumption(mW) <50 <50 <50 Mechanical Data Ambient temperature range(°C) -40-+65 REVISION Dimensions(WxHxD mm) 280 x 176 x 33 DATE DESCRIPTION Weight(kG) 3.75(including 2.32m AC cable) Enclosure rating Outdoor-NEMA(IP67) Cooling Natural convection-No fans Features Communication 2.4GHz Proprietary RF(Nordic) DATE 5/14/21 Monitoring Hoymiles Monitoring System DRAWN: Warranty Up to 25 years SHEET TITLE Compliance UL1741,IEEE1547,UL1741 SA(240Vac),CA Rule21(240Vac),CSA C22.2 No.107.1-16,FCC 158,FCC 15C PV Rapid Shutdown Conforms with NEC-2014 and NEC-2017 Article 690.12 MICROINVERTER and CEC-2018 Sec 64-218 Rapid Shutdown of PV Systems DATA SHEET *1 Nominal voltage/frequency range can be changed due to the requirements of local power department. *2 Refer to local requirements for exact number of microinverters per branch. SHEET NUMBER E - 6 „,. J I 1 13 OFOR CODE co �,A `W� 11 Y O t9 Tech Brief Tech Brief i n f i n i ty solar G RON IDGE XR Rail Family XR Rail Family INFINITY405 EOMILL PLAINME 6 VANCOUVER,WA 98661'�' The XR Rail Familyoffers the stren strength of a curved rail in three targeted sizes. Each size su orts s ecific �� Is` design g g pp p PHONE: 1 800 818 0598 Soi 1 Jog.kf*IayS Sunny { design loads,while minimizing material costs. Depending on your location,there is an XR Rail to match. .44t Over their lifetime, solar panels experience countless ;` a extreme weather events. Not just the worst storms in years, �, lb but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. 41b4111717 t *XR Rails are the structural backbone preventing i ,„ these results.They resist uplift, protect \\�� XR10 XR100 XR1000 against buckling and safely and efficientlykit*,1,, . XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among transfer loads into the building structure. rail,designed for regions with light or mounting rail.It supports a range of and snow conditions,while also solar mounting rails.It's built to handle Their su erior spanning ca abilit no snow.It achieves 6 foot spans,while windextreme climates and spans 12 feet or p p f p y remaining light and economical. maximizing spans up to 8 feet. more for commercial applications. requires fewer roof attachments, %& reducing the number of roof L �4 • 6'spanning capability • 8'spanning capability • 12'spanning capability PROJECT DETAILS penetrations and the amount / \ • Moderate load capability • Heavy load capability • Extreme load capability 1�� \\_ • Clear&black anodized finish • Clear&black anodized finish • Clear anodized finish of installation time. ,\( \ • Internal splices available • Internal splices available • Internal splices available 4.340 DC KW 4.800 KW CEC-AC RATING MS Ti SYSTEM 0 ,, Rail Selection 5° 90° TILT AZIMUTH The following table was prepared in compliance with applicable engineering codes and standards. Values are CUSTOMER INFO based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft.Visit IronRidge.com for detailed span tables and certifications. 2005 1 OTH ST ,/ ANACORTES, Load Rail Span WA 9822 Snow(PSF) Wind(MPH) 4' 5'4" 6' 8' 10' 12' TOM FLANAGAN Force-Stabilizing Curve 100 Sloped roofs generate both vertical and lateral 120 1411.4f _ forces on mounting rails which can cause them None - to bend and twist.The curved shape of XR Rails 140 XR10 XR100 is specially designed to increase strength in both directions while resisting the twisting.This unique feature ensures greater security during extreme 160 weather and a longer system lifetime. REVISION 100 DATE DESCRIPTION 120 10-20 140 160 100 4111 30 DATE 5/14/21 160 DRAWN: Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 100 SHEET TITLE XR Rails are IronRidge offers All XR Rails are made of 6000-series ib. 40 RACKING " ^` compatible with a range of tilt leg aluminum alloy,then protected with an 160 Ir 11 oot and 1 options for flat anodized finish.Anodizing prevents surface DATA SHEET I other pitched roof roof mounting and structural corrosion,while also providingSill 50-70 160 _IMIIIIIIaillMll attachments. applications. a more attractive appearance. 80 90 160 SHEET NUMBER ©2014 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.13 ,IA_ s - i f I 1 �QFOR CODEC,O infinity solar w� A{� no i c e„Aci, Cut Sheet SUNM•Dm° Cut Sheet INFINITY HOME SOLUTIONS 16111411, 6405 E MILL PLAIN 891 1.Nano Mount 1.Nano Mount VANCOUVER,WA 98661 _ . o� _ _ os PHONE: 1-800-818-0598 Nanoi`o"�o tntr"' ( ',Rfter) _ o NanoMountTM (Decking) _ -a- .�_- no.ul�. -o— 0 —0- + a .. —0- II I42 of �., :, [ersl •as lif15,51 Q r . r I I I I I 1 1 ---- I.. m..� Dry,o.1 ~PA Ito,t7 ise Q Material:Aluminum Material:Aluminum a Finish:Black Powder Coating Finish:Black Powder Coating i a i a a 2.Nano Gasket — iso1 2.Nano Gasket risza� PROJECT DETAILS a a a 1 a — — ��66 f73.fifi 4.340 DC KW �149J.o1 o 0l s 4.800 KW CEC-AC RATING i MICROINVERTER SYSTEM + + 50 9Oo TILT AZIMUTH 4.7 CUSTOMER INFO 2005 10TH ST ANACORTES, Material:USWR Gasket with Adhesive Material:USWR Gasket with Adhesive WA 9822 1 TOM FLANAGAN 3.Hex Lag Bolt M8X115,DIN 571,304SS 3.Self-Tapping Screw,#6.3 X 76 Part Description: Nano Rafter Mount, Black "" mt., feranir 31 Part No.: K50053-BK1 �ii�►itint►tiiii►►�t�� ii►C As% zs Part Description: Nano Deck Mount Black ��JiltatlatininS2REVISION pit, .. Part No.: K50053-BK3 "s_ DATE DESCRIPTION Material:Stainless Steel Material:Stainless Steel Finish:Clear Finish:Clear Item Description Qty in Item Description Qty in No. Kit No. Kit 4.Sealing Washer.331D X.75X.157 4.Sealing Washer.261D X.50X.125 1 Nano Rafter Mount Assembly 1 1 Nano Deck Mount Assembly 1 — • Nano Rafter Mount • Nano Deck Mount DATE • Nano Gasket I • Nano Gasket \ rem DRAWN: 5/14/21 mo� F SHEET TITLE 00.75 ON 0003 11024 MO) Mg 2 Lag Bolt Assembly 1 t__ 2 Decking Screw Assembly 4 F__ �� RACKING • Hex Lag Bolt M8X115,DIN 571,304S I i • Self-Tapping Screw,#6.3 X 76 DATA SHEET • Sealing Washer.33 ID X.75 X.157 , — �.. • Sealing Washer.261D X.50X.125 en Material:EPDM+Stainless Steel Material:EPDM+Stainless Steel D10213-vOO1 D10214-v002 SHEET NUMBER Dimensions shown are inches(and millimeters) Details are subject to change without notice Dimensions shown are inches(and millimeters) Details are subject to change without notice S - 2 2 \,... 4/ r 1 13 FO[t CODE co 4O W 411 O 4A Tech Brief Tech Brief infinity solar � IDLE UFO Family of Components System Diagram INFINITY HOME SOLUTIONS Y c, 6405 E MILL PLAIN VANCOUVER,WA 98661 � ,,tx 1891 -yy , . , 4 .'S o PHONE: 1-800-818-0598 .- fie, triding for Every Application _s =• 0 O- - -m- - - �= The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails.All system types that feature the UFO family—Flush Mount,Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding paths throughout the system.This leads to safer and more reliable installations. ( fil....---a 1 ff ) a O- - :OD_ - -O 0 • E= :11.0 /) PROJECT DETAILS 10 Stopper Sleeve Universal Fastening Object(UFO) 4.340 DC KW The Stopper Sleeve snaps The UFO securely bonds solar modules to XR 4.800 KW CEC-AC RATING onto the UFO,converting it into Rails.It comes assembled and lubricated,and - MICROINVERTER SYSTEM a bonded end clamp. can fit a wide range of module heights. �• O O— — —m— — —O 0 OE 5° 90° — TILT AZIMUTH " � CUSTOMER INFO i - - - , _ - 2005 1 OTH ST O UFO Stopper Sleeve • Grounding Lug I Bonded Splice Ground Wire ANAGORTES, 'f — WA 98221 - - - 7;7 ' - _ _l am, C' TOM FLANAGAN ti - i„ , may\ `/ 4 Approved Enphase microinverters can provide equipment grounding of IronRidge systems,eliminating the need for grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the x� same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. k� ti��k A®��. =�. �S UL Certification Cross-System Compatibility REVISION %� The IronRidge Flush Mount, Feature Flush Mount Tilt Mount Ground Mount DATE DESCRIPTION — Tilt Mount, and Ground Mount XR Rails d d XR1000 Only Bonded Splice ��t.. / Systems have been listed to UL Each Bonded Splice uses �� / \t,;, 2703 by Intertek Group plc. UFO/Stopper d v d self-drilling screws to form �� a secure connection.No Bonded Splice d V N/A bonding strap needed. / �� UL 2703 is the standard for ��/�/ evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array systems. It ensures these devices DATE 5/14/21 Microinverters Enphase M250-72,M250-60,M215-60,C250-72 DRAWN: I will maintain strong electrical and &Power Darfon-MIG240, MIG300,G320,G640 Grounding Lug mechanical connections over SHEET TITLE o ®Y A single Grounding Lug Bonded Attachments Optimizers SolarEdge-P300, P320, P400, P405, P600,P700, P730 k� an extended period of time in connects an entire row The bonding bolt attaches of PV modules to the and bonds the L-foot to the extreme outdoor environments. Fire Rating Class A Class A I N/A RACKING - - . rail.It is installed with the GROUNDING Tested or Evaluated with over 400 Framed Modules same socket as the rest of the Modules system. O Go to IronRidge.Com/UFO Refer to installation manuals for a detailed list. SHEET NUMBER ©2016 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or cat 1-800-227-9523 for more information.Version 1.10 S - 3 \.. J ,e5) EcoA{ infinity solar voi28375 Industrial Blvd. 28375 Industrial Blvd. �, 91- Hayward,CA 94545 Hayward,CA 94545 • , ' DGE 1-800-227-9523 IRONRIDGE 1-800-227-9523 IronRidge.com IronRidge.com INFINITY HOME SOLUTIONS OOP 6405 E MILL PLAIN 1891 w� VANCOUVER,WA 98661 PHONE: 1-800-818-0598 Attt @ r, COIF IronRidge Inc. The parameters and adjustments allowed in the span tables are defined as the following: Date: `�ti M*Art4 320 1. The Flush Mount System is designed as a Risk Category II structure as defined by ASCE 7-10 Chart 1.5-1. Re:Structural Certification and Span Tables for IronRidge Flush Mount System 2. The wind speed selection shall conform to ASCE 7-10 Fig.26.5-1A(Risk Category II wind)and any state&local This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System.The contents county/city amendments to the IBC. No special wind topographic features are included in the span tables and the of the letter shall be read in its entirety before being applied to any project design.The Flush Mount System is a topographic coefficient(Kzt)is taken as 1.0. proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and 3. The snow load used in the span tables is the ground snow and shall conform to ASCE 7-10 Fig.7-1 and secured to the rails with IronRidge mounting clamps.The XR Rails are side mounted to a selected roof attachment with applicable state&local county/city amendments to the IBC. If the local jurisdiction specified snow load is in the 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to format of a flat roof snow load,it shall first be converted to a ground snow following the local building the underlying roof structure.Assembly details of a typical Flush Mount installation and its core components are shown in code/amendment before the application of the attached span tables.No special snow conditions are considered Exhibit EX-0015. including unbalanced,drifting,sliding,retention,or ponding snow.The span tables do not include buildings which are intentionally kept below freezing,kept just above freezing,or unheated. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards 4. The span tables reflect the ASCE 7 prescribed earthquake loads with the maximum magnitudes being: PROJECT DETAILS listed below,for the load conditions and configurations tabulated in the attached span tables. 1) For ground snow no greater than 42psf:SS 5.2.0g for Site Class A, B,C,or D. 4.340 DC KW • ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures(ASCE 7-10) 4.800 KW CEC-AC RATING 2) For ground snow greater than 65psf:SS 51.Og for Site Class A,B,C,or D. • 2015 International Building Code(IBC-2015) MICROINVERTER SYSTEM 3) For ground snow between 42 and 65psf:SS 5 1.5g for Site Class A,B,C,or D. • Washington State Building Code Amendment WAC 51-50 5° 90° • 2015 Aluminum Design Manual(ADM-2015) TILT AZIMUTH 5. Roof zone size and definition conforms to ASCE 7-10 Fig.30.4-2A to 30.4-2C. CUSTOMER INFO The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the 6. Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over a respective loads and configurations listed,covering wind exposure categories B,C,&D,roof zones 1,2&3,and roof minimum of three spans. 2005 7 OTH ST slopes from 8°to 45°.The span tables are applicable provided that the following conditions are met: ANACORTES, 7. The maximum cantilever length measured from the rail end to the nearest attachment point shall not exceed 40% WA 98221 1. Span is the distance between two adjacent roof attachment points(measured at the center of the attachment of the allowable span provided for the respective load&configuration condition from the span tables. fastener) TOM FLANAGAN 8. An array to roof clearance of 2"minimum must be provided. 2. The underlying roof pitch,measured between roof surface and horizontal plane,is 45°or less. 9. No rail splices are allowed in the cantilever,outer 2/3 of end spans,or middle 1/3 of interior spans. 3. The mean roof height,defined as the average of the roof eave height and the roof ridge height measured from grade,does not exceed 30 feet. 10. Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded. If such conditions are encountered contact support@ironridge.com. REVISION 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module DATE DESCRIPTION 11. When a roof attachment listed in IronRidge's Flush Mount installation manual is considered,the span values width shall not exceed 42". provided in this letter can be adjusted using IronRidge's online Design Assistant by checking the capacity of the 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount selected roof attachment against the reaction forces provided in Design Assistant. installation manual and other applicable standards for general roof construction practice. DATE 5/14/21 DRAWN: SHEET TITLE RACKING ENGINEERING ©2020 IronRidge,Inc. WA Flush Mount System Certification Letter-1 ©2020 IronRidge,Inc. WA Flush Mount System Certification Letter-2 LETTER SHEET NUMBER S - 4 J r 1 1.47.1 o CODEC, 28375 Industrial Blvd. $QF O� I28375 Industrial Blvd. Hayward,CA 94545 infinity s o I r ' I Y A0 { Hayward,CA 94545 Haywar1-800-2d,CA 9 S. IR +' Y DOE 1-800-227-9523 /�� IRON RI DGE 3 IronRid e.com INFINITY HOME SOLUTIONS IronRidge.com g 6405 E MILL PLAIN a91 VANCOUVER,WA 98661 lila MO module clamps shall be installed with the following guidance: PHONE: 1-800-8 1 8-0598 r� The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no ��ro FtEq�t $or single module installations("orphan modules")using modules with a length greater than 67.5", consideration of the structural adequacy of the chosen roof attachments, PV modules,or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the CAMO clamps shall not be installed in regions that experience ground snow loads of 70psf and aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. greater:such scenarios are shown by asterisks in the applicable span table. 2) CAMO will function within a module's design load ratings. Be sure the specific module being used with Sincerely, CAMO meets the dimensional requirements shown in the figure below and that the module selected is __, suitable for the environmental conditions of a particular project. c�pNc „ Date: yP� 2020.05.22 r Module Glass/Cells a i 5; gg rore O,`i 12:58:18 r-A, -GismoSS'oNnt o—'c` —07t00t Gang Xuan,PE PROJECT DETAILS Senior Structural Engineer 4.340DCKW Frame COmpOtlt7lllf 4.800 KW CEC-AC RATING x- 1.2 2.2 mm MICROINVERTER SYSTEM Y= 15-4D mm 5° 90° TILT AZIMUTH Y CUSTOMER INFO 1--x 2005 7 OTH ST —f ANACORTES, Figure l:CAMO Module Frame Dimensional Requirements WA 9822 1 TOM FLANAGAN REVISION DATE DESCRIPTION DATE 5/14/21 DRAWN: SHEET TITLE RACKING ENGINEERING ©2020 IronRidge,Inc. WA Flush Mount System Certification Letter-3 ©2020 IronRidge,Inc. WA Flush Mount System Certification Letter-4 LETTE R SHEET NUMBER S - S ,.,. 5 I 1 13 .,,,a,OR CODE cQ' o infinity sOl a r RAT i?_ � ,�� 2005 10th Street(#772383) /1� IRONRIDGE pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 1111.11ffrs re INFINITY HOME SOLUTIONS UL 2703 LI- - Project Details 6405 E MILL PLAIN �} 1891 4 Name 2005 10th Street Date 05/15/2021 VANCOUVER,WA 98661 Y o PHONE: 1-800-818-0598 4COg� �� Location 2005 10th Street,Anacortes,WA 98221 Total modules 14 (14, �7 ,R$e� ModuleCustom Panels Suntech STP3105-20/WfbTotal watts4,340 US #5003807 Dimensions 64.96"x 39.06"x 1.38"(1650.0mm x 992.0mm x 35.0mm) Attachments 36 are Intertek ASCE 7-10 • Conforms to STD UL 2703(2015)Standard for Safety First Edition: Mounting Systems, Mounting Devices,Clamping/ Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels. System Weight Load Assumptions • Max Overcurrent Protective Device(OCPD) Rating:25A Total system weight 667.9 lbs Wind exposure D • Max Module Size:24ft2 Weight/attachment 18.6 lbs Wind speed 110 mph • Module Orientation: Portrait or Landscape • CAMO Specific Allowable Design Load Rating:50 PSF downward,50 PSF upward, 15 PSF lateral Racking weight 103.2 lbs Ground snow load 25 psf • System Level Allowable Design Load Rating:meets minimum requirements of the standard(10 PSF downward,5 Distributed weight 2.6 psf Attachment spacing portrait 3.0' PSF upward,5 PSF lateral).Actual system structural capacity is defined by PE stamped certification letters. CLASS A SYSTEM FIRE RATING PER UL 1703 Roof Information PROJECT DETAILS • Any Roof Slope with Module Types 1,2,and 3 Roof material Other Building height 15 ft • Any module-to-roof gap is permitted,with no perimeter guarding required.This rating is applicable with any third-party Roof attachment L-Foot Only Roof slope 9° 4.340 DC KW attachment. 4.800 KW CEC-AC RATING • Class A rated PV systems can be installed on Class A, B,and C roofs without affecting the roof fire rating. Attachment hardware Square Risk category II MICROINVERTER SYSTEM WATER SEAL RATINGS:UL 441 &TAS 100(A)-95(FLASHFOOT2,ALL TILE HOOK, KNOCKOUT TILE) 5° 90° Span Details XR100 - Portrait Reaction Forces XR100 - Portrait TILT AZIMUTH •Tested and evaluated without sealant. Down uplift Lateral Zone CUSTOMER INFO •Any roofing manufacturer approved sealant is allowed. Ratings applicable for roof slopes between 2:12 and 12:12 Zone Max span Max cantilever (lbs) (lbs) (Ibs) 1 8' 3'2" 1 196 103 30 2005 1 OTH ST STRUCTURAL CERTIFICATION ANACORTES, 2 8' 3'2" 2 196 208 30 1 • Designed and Certified for Compliance with the International Building Code&ASCE/SEI-7 3 6'9" 2'8" 3 196 327 30 WA 9822 TOM FLANAGAN Roof Section 1 Definition Roof Section Weights Roof Section(all segments) 14 modules Total weight:667.9 lbs Provided rail:112'[8 x 14'] East-West rail orientation Weight/attachment:18.6 lbs Attachments:36 Portrait orientation Total Area:252.7 sq ft Splices:0 REVISION Graphical entry Distributed weight:2.6 psf Clamps:36 DATE DESCRIPTION Diagram UM o HI MI o 32'10" 1 DATE 5/14/21 Segments DRAWN: SHEET TITLE Columns Length Cantilever Cantilever Violations Rail Attachments Splices Clamps 4 13'3" 8" None 28'[2 x 14'] 10 0 10 RACKING " Row segment totals(x 2)-, 56'[4 x 14'] 20 0 20 GERTIFIGATION 3 10' 6" None 28'[2 x 14'] 8 0 8 Row segment totals(x 2)-r 56'[4 x 141 16 0 16 & REPORT SHEET NUMBER S - 6 \.,.... J 11 Y o PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT �'� Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location:904 6th Street, Anacortes WA 98821 Y;:+111631K.� Phone: (360)293-1901 o FORM BP-1: RESIDENTIAL BUILDING PERMIT APPLICATION 1. PROPERTY INFORMATION Project Address(Street,Suite#): Assessor Parcel Number: 2005 10th St Anacortes, WA 98221 P56126 Subdivision/Lot#: Zoning Designation: Lot area (size): ANACORTES 6098.40 sq.ft. 2. TYPE OF PROJECT ❑ New SFR ❑ New Accessory Dwelling Unit: ❑ Deck/porch (new/repair) ❑ New Duplex ❑ Attached to Primary Unit ❑ Interior remodel ❑ Detached from Primary Unit ❑ New Addition to SFR ❑ Garage, carport or accessory building E Fence or retaining wall or duplex (new/repair) I■P Other: Solar Project Summary: Installation of 14 solar panels in 2 array(s) on a roof mounted 4.34kW PV System Project Valuation: $4,959.00 3. PROPERTY OWNER INFORMATION Name:Tom Flanagan Phone:(360) 293-4090 Address(Street,City,State,Zip): 2005 10th St Email Address: Anacortes,WA 98221 tomflanagan1 @comcast.net 4. CONTRACTOR INFORMATION Name:*TML International LLC Phone:(800) 818-0598 Contractor's Business Licenses State License#:TMLINIL807PW City License#:603 506 437 *All Contractors&Subcontractors must have a valid City of Anacortes business license prior to doing work in the Expiration Date: 10/20/2022 Expiration Date: 10/31/2021 City. Address(Street,City,State,Zip):6405 E Mill Plain Blvd Email Address:permit@infinitysolarusa.corn Vdncouver,WA 5. CONTACT PERSON 98661 Select one person the city will contact for anything 0 Applicant ❑ Property Owner ❑� Contractor related to this project: ❑ Other(list below) Name:Maggie Ludden Phone:(360)836-1729 Address(Street,City,State,Zip):6405 E Mill Plain Email Address: permit@infinitysolarusa.com Blvd Vancouver, WA 98661 Res.Building Permit Application Submittal Checklist Updated October 10,2019 Page 5 of 18 I;GI � PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 �co�7`�' Phone: (360)293-1901 6. LENDER INFORMATION RCW 19.27.095 requires the City to obtain information with regard to lenders. If there are no lenders involved with your project, write"no lenders"on the Name Line below. Name:No Lenders Phone: Address(Street,City,State,Zip): Email Address: 7. ACKNOWLEDGEMENTS & SIGNATURE Read and initial each of the following statements prior to signing this application: I understand that when a building permit application is taken in over the counter it does not mean the application has been deemed technically complete and sufficient for staff review. 0ti- dr/ I understand that if I submit incomplete, inaccurate, and/or erroneous information it will take the City longer to process my permits. / rI understand and acknowledge that I could be responsible for providing as built drawings (on paper Op oilelectronically) as part of the project's certificate of occupancy process. I understand and acknowledge that Special Inspections could be required as part of my project, and Op' if needed I will be required to pay for the cost of these inspections. I understand and acknowledge that financial securities could be required as part of the work I am Opcompleting and I agree to provide the items needed for the City to calculate these securities and to .rovide the securities themselves. I understand that if permits are reviewed concurrently such as design review, site plan,traffic / concurrency, etc., any required revisions to one permit may affect the entire plan set and could add costs and time to the project. I hereby declare that I am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. I also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein, and the information submitted with this application form is in all respects, true, correct, and complete to the best of knowledge and belief. 5. 19.21 Signature Date Maggie Ludden Printed Name Res.Building Permit Application Submittal Checklist Updated October 10,2019 Page 6 of 18 �QFOR CODE c,D1,o 4 G1� Y To Be Completed By the Applicant , m Pr address: 2005 10th St Anacortes, WA 98221 Maggie Ludden for TML International LLC Project Applicant: gg Applicant Email: permit@infinitysolarusa.com Phone No.: (360) 836-1729 Site Owner Name:Tom Flanagan PV System Description: Installation of 14 solar panels in 2 array(s) on a roof mounted 4.34kW PV System Determine if your project is eligible for an over-the-counter Permit(Check Yes or No) Yes No 1. PV System is designed and proposed for a detached single-family house,duplex or p ❑ town home. 2. PV System is designed for rooftop of house in general compliance with applicable p ❑ codes. 3. Mounting system is engineered and designed for PV. p ❑ 4. Rooftop is made from light weight material such as shingles. p ❑ 5. PV system will be permitted and pre-approved by Labor& Industries Electrical p ❑ division. 6. To address uplift, panel are mounted no higher than 18"above the surface of the p ❑ roofing to which they are affixed. Except for flat roofs, no portion of the system may exceed the highest point of the roof. 7. Total deal load of panels,supports, mountings, race ways,and all other p ❑ appurtenances weight no more than one of the following. IF Yes, indicate which: o No more than three and one half(3.5 pounds per square foot(PSF) o Frameless panels on at least 3/12 pitch roof weighing no more than four and one-half(4.5) PSF o Frameless panels on at least 5/12 pitch roof weighing no more than five(5.0) PSF 8. Supports for solar panels are installed to spread the dead load across as many p ❑ roof-framing members as needed to ensure that no point loads in excess of fifty (50) pounds are created. 9. Attachment to the roof is specified by the mounting system manufacturer. p ❑ 10. Panels are mounted no higher than the roof ridge or apex of roof(applies only to p ❑ pitched roofs). Comments: Ge By Checking this box, I certify that all of the information provided on this form is correct. If you answered yes to all of the above questions,your PV installation is eligible for an over-the-counter building permit. To apply please bring in this completed form to our permit center at City Hall for an over-the-counter permit. To be Completed By Staff Project is eligible for over-the-counter permit? ❑Yes ❑ No