HomeMy WebLinkAboutPermit File 3601 Malland Court II
II/ \a i
' 0 " O . CITY OF ANACORTES r
WASHINGTON 111
2 `' BUILDING DEPARTMENT
9Ca Rt
CERTIFICATE OF OCCUPANCY
This is to certify that the(Description of Building or Structure):
` Single Family Residence
Located At:
3601 'Holland Court
STREET B NUMBER
Owner Buries-Lead Northwest inc,
Constructed By: onlcdtead Northwest
OWNER OR CONTRACTOR
:' Bldg. Permit#: B162002-8101
, Date Issued: 10/17/2002
r Occ. Group: R3 Use Zone: 113 11,
Has Been Inspected And Occupancy Is Hereby Authorized.
This casth. Day of Jan 20 03
(AUTHtJt�.ING OF0 -
ORIZING OFff41AL
SEE REVERSE SIDE FOR SPECIAL REQUIREMENTS. t
it
-JOT 1-T Y O .. City of Anacortes Permit#: BLD-2002-8101
904 6th Street Issue date: 10/17/2002
+ Anacortes,
547 Expire date: 10/17/2003
�' 'to Anacortes, WA 98221-0547
,`` �? (360)293-1901
Job Address: 3601 MALLAND CT
ANACORTES WA 98221
APN:
Permit Type: Single Family Residence Permit
Project:
Remarks: Construct new single family residence per approved plans as noted.
Applicant: HOMESTEAD NORTHWEST, INC Owner: HOMESTEAD NORTHWEST, INC
Address: PO BOX 409 Address: PO BOX 409
LYNDEN, WA 98264-0409 LYNDEN WA 98264-0409
Phone: (360)543-366 Phone: (360)543-366
Contractor: HOMESTEAD NORTHWEST INC
Addressr: PO BOX 409
LYNDEN WA 98264-0409
Phone: (360)354-3366
License#: HOMESNIO88CE
General Information: Fees:
Lot Area 6880 Traffic Impact Fee 650.00
1st Floor Square Footage 791 Building Permit Fee 595.50
2nd Floor Square Footage 1312 Plan Review Fee 387.08
Garage Square Footage 521 Mechanical Permit Fees 114.65
Building Valuation 165000 Plumbing Permit Fee 125.00
# Forced Air Furnace<=1,000 1 State Building Code Fee 4.50
#of Bathtubs 2 Sewer Inspection Fee 50.00
#of Clothes Dryers 1 Sewer Connection Fee 3,960.00
#of Clothes Washers 1 Storm Drain Fee 1,126.00
#of Dishwashers 1 Park Impact Fee 615.00
#of Gas Fireplace 1 Total Calculated: 7,627.73
#of Gas Piping 1 Deposits/Receipts: 0.00
#of Gas Water Heaters 1
#of Water Piping 1 Total Due: 7,627.73
#of Hose Bibbs 2
#of Kitchen Sinks 1
#of Lavatories 3
#of Range Hoods 1
#of Slop Sinks 1
4 of Ventilation Fans 4
#of Water Closets 3
THIS APPLICATION IS RECEIVED BY THE BUILDING OFFICIAL UNDER THE PROVISIONS OF THE UNIFORM BUILDING CODE,AND SHALL EXPIRE
BY LIMITATION AND BECOME NULL AND VOID IF PERMIT IS NOT OBTAINED WITHIN 180 DAYS OF THIS APPLICATION. BY AFFIXING MY
SIGNATURE I HEREBY CERTIFY THAT I AM THE LEGAL OWNER OF THE PROPERTY FOR WHICH THIS APPLICATION IS ISSUED OR AN
AUTHORIZED AGENT OF THE OWNER. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED
WITH WHETH S CIFIED HEREIN OR NOT,INCLUDING CALLS FOR INSPECTIONS.
Applicant Signature Issued by
PAGE 1 OF 1
PROPOSED
rE MACINTOSH l
II FNDN.
FINISHED 1111111 IIII IIIIIIIVII IIIIIIII IIIIVIIJ
GRADE ....es
_ I
EXISTING
GRADE
120 110 100 90 80 10 60 50 40 30 20 10
121.96 0
5' SIDE
TRACK
_- ' N 89'S3' E -
------'t--121.-96
----- ----� --
\ 42'-4" 36'-l"I
I 1 20' PUBLIC SD
20' FRONT ': 1 • ' \> . '• I I X / EASEMENT
SETBACK \.4 i r\ - .• t .• I I 20' REAR
`
\4 • 13DRIVESY'.. 1 Le/� FRO SEID
% s. • MAC T O S H j SETBACK
° . I 1 31 •
10' UTILITY Y 130-2 1 . J- T I ?-f;n
EASEMENT I P I 1 • , @'
I PATIO I
a - -
a l I —
11
0 I
N89°53' E -1---�
94.5' --- —'t---LOT 5 1--
0' SIDE I
IMPERVIOUS SURFACE CALCULATIONS SETBACK 4 MALLAND
kl
LOT AREA: 6,880 SF MEADOWS
1-LOUSE AREA: 1,432 SF
LOT *5
CONCRETE AREA: 81$ SF • " n ANACORTES, WA.
TOTAL IMPERVIOUS AREA: 2,241 SF SCALE' T • 20'
PERCENT OF LOT COVERED: 32.6%
n
i4, m .y(w g,1,,,fry.anr4 ANy 9 �a [[ A,
}[".'z.�4�%�it4 k'n'.t' � ..i�e� r��gg " � ""�> Y:"�rY> PY x
ft 4 "`7. %:<;.- r i
.{n t r x 7.ry=e t' ' ;i,#., •n4 v7.7 „ a l Trl ,: . 7 �' 2 %;� f f �. ..ti
'uY� .�ti:.,cozn a.�,..�.,• xxmx:se. n:.t .C.�r, t�'^�.4�". .. �'w ...,... . -i 2.:h�'���:-o
(This form is to be completed prior
to issuing the building permit)
Site Address: 3Cc O ` ��(/ 'ac t., Sk// •-•., Yl /� Date: (0 —
Contact Person: �l1<<y�l�k Phone No.: geln 23Cea
Assessors No.:?\\)?1 ( 0 Lot:
Block: Addition:
(Building Department Checklist for Completeness)
OK NA OK NA
It ❑ Fire Department Access 43.., ❑ Fire Hydrant Located within 250 feet
,g,L. ❑ Fire Flow Required 3Ja ik SF, ❑ [r Shoreline or Wetlands
[off ❑ Site Plan ❑ a Covenant Approval
❑ g Variance Required ❑ I}+ Regulated Slopes
❑ 44 Plat Facts and Findings Compliance D Survey in File
❑ ,Q Fill on Site
Received and Reviewed by: Date: 4 ' o v --
(Engineering Department Checklist for Completeness)
OK NA OK NA
❑ 0 Water Extension/Meter ❑ 0 Sewer Extension/Connection
❑ 0 Street Improvements/Sidewalks ❑ 0 Site Drainage Plan
❑ ❑ Covenant Not to Oppose Future LID ❑ ❑ Latecomers Agreement
❑ ❑ Street Drainage ❑ 0 Driveway location, slope, culvert
❑ ❑ Storm Drain Extension
Received and Reviewed by: Date:
Zoning: .VS 3
Lot Size: CQf O O \ F
Coverage Allowed: 0 S E
g 3 ��
Actual Coverage: \p S .
/e-3/-off El
Sewe2
3.4c/ 191 --//t'ild Cr
3601
mxiiR4/ c-r,
•
-3
9.
o'
> sub
9 '
cf