Loading...
HomeMy WebLinkAboutPermit File 4918 Macbeth Drive 0530504-2 0001 11/01/2005 002 8 Permit Fees 006747 $55.00 " S X c7 `4, City of Anacortes Permit#: BLD-2005-0852 904 6th Street Issue date: 11/01/2005 ‘40011111111ear P.O.Box 547 Expire date: 11/01/2006 02; Anacortes, WA 98221-0547 Job Address: 4918 MACBETH DR Permit Type: Reroof Single Family Residence ANACORTES WA 98221-3026 Project: APN: P59786 Remarks: Apply second layer of composition roofing. Owner: FINGER JOHN C/RITA C REV LIV T Contractor: OLYMPIC CONSTRUCTION Address: 4918 MACBETH DR Address: PO BOX 732 ANACORTES WA 98221-3026 ANACORTES WA 98221 Phone: (831) 901-4287 Phone: (360)420-6887 License#: OLYMPL*957JA General Information: Fees: Occupancy Group it-1 Building Permit Fee 50.50 Building Valuation 4500 State Building Code Fee 4.50 Total Calculated: 55.00 Deposits/Receipts: 0.00 Total Due: 55.00 it THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING0 CONSTRUCTION OR THE PERFORMANCE OF CONSSTTRUUCCTION. 71 2i Br '� Uzi l /U7 SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUE LI aa0a00aaaa0000a0a000aa00000000a0aaa0a0000aa0E1 • o ° a °❑ a _ °❑ Li INSULATION CERTIFICATION o a a a THIS IS TO CERTIFY THAT, IN CONFORMANCE WITH THE CURRENT THERMAL PERFORMANCE STANDARDS (REVISED CODE OF WASHINGTON, TITLE 19.27, STATE OF WASHINGTON*)AND APPROVED PLANS, INSULATION HAS BEEN a INSTeLLED IN THE BUILDING LOCATED T: a co re-, )SraCnrnaS Li a ADDRESS OF PROPERTY _ BLDG. PERMIT NO. °❑ ❑ a p a DESCRIPTION OF INSTALLATION a a a e❑ ROOFS a aType of Material Manufacturer Thickness R Value** a a1c a ❑o EXTERIOR WALLA) 11/^ /� Iqli /9 / ° CI Type of Material T I U Manufacturer O/G Thickness i /,{- R Value** / / DICEILINGS /� y^ n _.���-�y}>�, a aBType:of Material r-1 G Manufacturer 0/C, Thickness / I/G R Value** W a a ddd ❑ El _ Sq. Ft. Covered a aBLOWN: /� DI Type of Material F\G Manufacturer (J Jr` . Thickness 113 No. Bags Iq a ❑ 2 yq[yq( • ° aWt./Bag �'1I�281 Sq. Ft. Covered R Value** �^/ �j /� / O FLOORS of Material r 1 Manufacturer 63 Thickness ' >,3 R Value** J / LI 0 SLAB ON GRADE 0 o Type of Material Manufacturer Thickness R Value** LI aWidth of Insulation _ Inches a a a a FOUNDATION WALLS (if required) °❑ aType of Material Manufacturer Thickness R Value** a °❑ DUCT AND/OR PIPE INSULATION a aType of Material Manufacturer Thickness R Value** a ) a a REMARKS ( if desired) a oGeneral Contractor (Builder) Contractor's Registration Number a a ❑ aBy - • Title Date p 3ONO-THERM INSULATION - # SO-NO-TI-264(� a J Sub-contractor (Insulation Applicator) Contractor's gistration Number 0 (Ins tion, Masonry, etc.) (State "SAME" if same as nasal Coot actor CI o J BY iii c ON /Title °`thein- with Date 0P-2 /tU l l a ^ dl Performance Standards,deelaree e" d bye „ No certificate of occupancy or similar certification that le , data MaY be a newly constructed apartment house three stories or less ❑ I ❑ fil ins is used the card shall show the square footage and the nuts and weight of/ago .- in height, home, or other residential dwelling is habit- able shall be issued by such a building department unless L:1 O the structure at least satisfies the minimum energy in- sulational standards established pursuant to this chapter. L.l alim (thermal eans iel or buildsng ,.t<.=<d,=,«°erlal only. _''val With'__.<_ll be "" "d.rm. .,. .° _ of Fundamentals.e. o El a a LII nnnnrnnnrnrriirnnnnnrnnnnnritrriu nrnrnnnnnnnnnnnnrinnf riii olralriFon! - y NI 1 Y0Ultyg of nacort lit ash in tanIP co <\ 90 BUILDING DEPARTMENT CERTIFICATE OF OCCUPANCY # S This is to certify that the (Description of Building or Structure): Q ren.,A Q GwA .j O44A Q Located At: 4 91 '- /V40.�+'ti// STREET& NUMBER C. Owner: � � r Constructed By: N R OR CONTRACTOR Bldg. Permit # 3/001n Date Of Issue: 623-23 Occ. Group: R Use Zone: ' L._- Has Been Inspected And Occupancy Is Hereby Authorized, F This 2 Day Of (it er 19' '6 R CTIKLAI 11T RING OFFICIAL \ SF, illf,VEI(SE;SIDE FOR SPECIAL REQUIREMENTS. R i CITY OF ANACORTES BLDG. X PLUMBING IX. MECHANICAL JK PERMIT ' an ANACORTES, WASH. DATE 5 - ^S ltl,3 PERMISSIO IS HEREBY `A�NT�,EDD TO:K p OWNER C + -- - * r ' I, � / V STREET ` f 91 f)---7s tar' ADDRESS �5 lli7 LOCATION WHERE WORK `IS TO BE DONE E � ` r CONTRACTOR tiEP` - . ), -E'i [ a/+e°.L E TO ERECT ®V INSTALL ® OR REPAIR ❑ IN THE F+LLO I M iiNER•':- I 1 it . _' w ats Li ' -. ,. . t4 - . FA )(Lana,.. PERMIT EXPIRE 0 E YEAR FROM DATE ISSUED PLANS FOR CONSTRUCTION WERE NOT G SUBMITTED WERE54 WORK TO BE DONE BY OWNER 0 CONTRACTOR$ RECEIPT OF FEES IS ACKNOWLEDGED AS FOLLOWS: TYPE APPROXIMATE VALUE PERMIT FEES OF WORK ISSUING - +• BUILDING fr 'rag! �r DT�I� GAS PIPING ���a�SI II PLUMBING AND W.S. mini# ILIn Mil M--M SEWER CONNECTION INSP. ���rag MECHANICAL y i f"�l�]i��f�`in PLAN CHECK FEE �-I�:L!IIi7�i MISC MIIMINIIr TOTAL WATINISIME LEGAL DESCRIPTION ,_ !W _ _J :c,w6 . h 3 _.3 71 - H - -- /�t I I I I : I I I I lg for� gat. /Z -1 ,1 1 i iii: i Il It PAGE 1 * CARRIER - HEAT PUMP AND AIR CONDITIONING * * R E S I DENT I A L LOAD ESTIMATE * *********************************************************- ---------- - ---- Prepared exclusively for : Estimate prepared by : • MR. & MRS. JOHN FINGER - MIKE STORY SKYLINE, ANACORTES Job No. BUILDER: PIAZZA CONST. Date: May 05, 1983 III - MD12102 0982 1 ** D Fr S I G N CONDITIONS - SUMMER WINTER ' . * OUTSIDE TEMPERATURE (DEG. F. ) 90 15 * INSIDE TEMPERATURE (DEG. F. ) 75 70 * DAILY TEMPERATURE RANGE (DEG. F. ) 0-25 -- * SUMMER SWING TEMP (DEG. F. ) 4. 5 -- 2 ** BUILDING - * TYPE: SINGLE-STORY * EXTERIOR WALLS: FRAME, 3.5 INCHES, R = 11 * WINDOWS: DOUBLE PANE, WEATHERSTRIPPED HORIZONTAL SLIDE * WINDOW SHADING: VENETIAN BLINDS OR DRAPES * DOORS: WOOD DOOR, WEATHERSTRIPPED OR WITH STORM DOOR * FIRST FLOOR: * OVER OPEN OR- VENTED SPACE OR GARAGE * INSULATION: 6-INCH INSULATION, R = 19 * ROOF/CEILINGS: ROOF COLOR IS DARK * CEILING UNDER VENTED ROOF OR UNCONDITIONED SPACE * INSULATION: 12-INCH INSULATION, R = 35 * DUCT LOCATED IN: UNCONDITIONED ENCLOSED CRAWL SPACE WITH 1-INCH FLEXIBLE INSULATION. * NUMBER OF SPACES HEATED AND COOLED: 3 ** SPACE H E- A T I N G & CO OLING L O 'A D S NO. ROOM NAME ITEM - AREA HEAT LOSS HEAT "GAIN . . (SQ FT) (BTU/HR) (BTU/HR) 1 ** BASEMENT WINDOWS - 40 2,440 2, 600 DOORS 40 . 6, 840 560 WALLS 624 2, 886 11950 FLOORS 360 792 0 ROOF/QEILING 0 0 0 SUB TOTAL 360 , 12, 958 5, 110 H/C FACTOR 0. 683 0. 808 TOTALS 360 119446 4, 126 PAGE _2.:; r!1-, a.% Sk f:. "z wy._r; *********)FiF1FiFiFIFIFIF7FiFifaF#1F1Fdh3F*7fiFih7F7F1FiFiF1F*1F1F-0F7FjFiF1FIF7FIF1k iE iFdF1F3FltiFlt .,. ” - _ * CARRIER - HEAT PUMP AND AIR CONDITIONING * * R E S I DENT 1 A L LOAD ESTIMATE * ********************************************************* //lir _ NO. ROOM NAME ITEM AREA HEAT LOSS HEAT GAIN (SQ FT) (BTU/HR) (BTU/HR) 2 ** 1ST FLOOR - - WINDOWS 487 29,707 26, 078 DOORS 110 18,810 1, 540 - WALLS 2, 600 12, 025 8, 125 " FLOORS 2,270 6, 303 1 ,528 ROOF/CEILING 2, 248 4,496 2, 922 INTERNAL LOAD 4,000 • SUB TOTAL 2,270 71 , 341 44, 193 H/C FACTOR 0. 883 0. 608 _ TOTALS 2,270 631016 35,686 - • ** ENTIRE HOUSE - WINDOWS 527 32, 147 28, 678 DOORS 150 25, 650 2, 100 WALLS '3,224 14, 911 10, 075 FLOORS 2,630 7, 095 1 ,526 ROOF/CEILING 2, 246 4, 496 2, 922 F INTERNAL LOAD 4, 000 SUE TOTAL 21630 84,299 49, 303 ' H/C FACTOR 0. 863 0. 606 TOTALS 2, 630 74,462 39, 612 ** E Q U I P M ENT SELECTION -* COOLING:G: * COOLING CAPACITY REQUIRED = 39, 812 BTU/HR a 90 DEGREES * COOLING CFM = 1 , 327 CFM I * HEAT PUMP COOLING CFM = 1, 531 CFM * HEAT I N G: * HEATING CAPACITY REQUIRED = 74, 462 BTU/HR 6 15 DEGREES * FURNACE HEATING CFM = 1 , 064 CFM NOTE: COMPUTED CFM' S ARE APPROXIMATE. *** ACTUAL EQUIPMENT SELECTED: IRON PIPE R = 1135' FOUND `--" L = 78.82; A = 3°58'44" 0 0 a p v —4 O t x 126 w REMARKS z Ln a THE RESURVEY OF THIS LOT WAS BASED ON THE INFOR- aLn - o NATION SHOWN ON SUBJECT PLAT, AND THE STREET MONUMENTS FOUND IN THE VICINITY OF THIS LOT AND N THE DIMENSIONS WERE ADJUSTED ACCORDINGLY (IF ANY). z L = 7i. 18; A = 3°58'44" R = 1025' Ln CENTERLINE OF MACBETH DRIVE J 0-4 _ . _.— . (50' R/W) iii �'.__� SYMBOLS: PIAZZA CONSTRUCTION �� J 114,410 PREPARED FOR: 2221 RIVERSIDE DRIVE o = REBAR (SET) �4�tlP � y� „9' MOUNT VERNON, WA 98273 TEL: (206) 424-3547 �P «� `'�� SCALE: 1" = 30' DRAWN BY: ® = MONUMENT (FOUND) y J.V. JOB NO: 1005-83 DATE: 5-i7--$3 APPROVED BY: DRAWING NO: - „ _ �F �p j DESCRIPTION, LOT 126 - SKYLINE NO. 8,lVOLUME 9 OF FLATS, PAGE 4�8FE¢ `♦a'ti 73, RECORDS OF SKAGIT COUNTY, WASHINGTON. ' ' tag . v JOHN J. VADAI & ASSOCIATES Phone: (206) 293-9591 2916 Commercial Ava_ . a"a,.,,r4e� ,,,, PRA cIANFTT DT AT