HomeMy WebLinkAboutPermit File BLD-2021-0168 1803 10th Street 1 City of Anacortes Invoice/Permit#: BLD-2021-0168
904 6th Street
Applied date: 03/03/2021
P.O.Box 547 Issue date: 03/10/2021
_ 0, Anacortes, WA 98221-0547
Expire date: 09/06/2022
(360) 293-1901
Job Address: 1803 10TH ST Permit Type: Single Family Alteration/Repair Permit
ANACORTES WA98221-1417 Project:
APN: P56056
Remarks: REMODEL BASEMENT.
Owner: RYAN WALTERS Contractor: TBD
Address: 1803 10TH ST Address:
ANACORTES WA 98221-1417
Phone: (360)420-3226 Phone:
License#:
General Information: Fees:
Flood plain development N Building Permit Fee 993.75
Building Valuation 100000 Plan Review Fee 645.94
Basement Square Footage 1300 State Building Code Fee Resi 6.50
Lot Area 6000 Mechanical Permit Fees 55.90
Zoning Code OLD TOWN Plumbing Permit Fee 90.00
#of Other Mechanical Units 1 Total Calculated: 1,792.09
#of Ventilation Fans 3 Deposits/Receipts: 0.00
#of Tubs, bath 1
#of utility Sinks 1 Total Due: 1,792.09
#of Showers 2
#of Hand Sinks 3
#of Water Closets(Toilets) 2
#of Water Heaters 1
The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of
the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or
granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or
federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be
valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this
jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order, proclamation, guidance advice or decision of
the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,
inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or
decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is
suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and examined this application and know the same to
be true and correct.
/Ye (
SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY
t7+14:30f, PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT
DEPARTMENT
Mailing Address: P.O. Box 547, Anacortes, WA 98221
Office Location: 904 6th Street, Anacortes WA 98821
Phone: (360) 293-1901
Instructions for Printing Digital Plan Review Documents
This City of Anacortes Planning,Community,and Economic Development has adopted an optional digital plan review
process,in response to COVID-19,for those who wish to reduce contact or reduce natural resource use. If you have
any questions please contact the The Permit Coordinator at 360-293-1901. We are also interested in any comments
you have to improve this system.
It is the applicant's responsibility to provide copies of all
approved submittal documents for use on the job site.
• Documents with color or with approval stamps are to be reproduced in
color, or black and red.
• Documents shall be provided in full size, and to scale.
• It is advisable to protect the documents from inclement weather. Plastic
sleeves are available upon request.
• All drawings, engineering, surveys, and supporting documents are
required to be on the job site at the time of inspections. If documents
are not available, the inspection will be cancelled. After the second
cancelled inspection, a re-inspection fee will be charged.
Be sure your packet includes:
• Permit
• Permit Inspection Card,print on heavy stock if possible. This will need to last the
duration of your project.
• Site Plan
• All Drawings
• Stormwater Plan or SWPPP
• Engineering, if included in submittal
• Landscape Plan
• Any other supporting reports or documents
Being properly prepared with the necessary plans on site will allow our
inspectors to complete your inspections. We appreciate your assistance.
4x6 beam
6x8 beam 2x4 wall with 2x4 supported by
supported by 2x4 top plate center 4x4 post
6x6 post 4x4 post wall 6x6 post
�QFOR CODE co
,'k' CA
Y O� 2 I. •1 - - I. .1 - - - I. .1 _ 1• .1 I /
M I
1891
6�✓� rO FIELD 1��C O g��`off
�5
o
Dryer duct to
outside(E)
i
\ r
1 IN
- - - 7 7 : .R'nace : Chimney )1i
--- —-- --- --- ---- ---- --
[6x8 beam _
supported by 2x4 b r
wall \
\ \ 1_
6x6 post;beam
rests on half of it
■1• •1 1• •1 1• •
Joists held to
double joist with 4x6 beam with
joist hangers 2x4 wall 6x6 post 4x4 post
supporting
Notes
All joists are 2"x10"at 16"OC;spacing exceptions noted.
All posts and beams are wood
Ryan Walters — 2/28/2021 — pg 1
Basement Walls, Joists, Beams, Posts (existing)
1803 10th Street, P56056
CITY OF ANACORTES
PLANNING AND BUILDING DEPT:
Old homes often have funky quirks that lead to APPROVED PLANS
Fipa is ated changes. Please feel free to request a REVIEWED FOR CODE COMPLIANCE
w4'�` 'P u with your inspector early and often. PERMIT#: BLD-2021-0168
��, It ADDRESS: 1803 0TH ST.
re APPROVED BY:7
SUBJECT TO FIELD INSPECTION.APPROVED PL S SHALL NOT
BE ALTERED WITHOUT AUTHORIZA ON.
/,', I�6
c'''tOFIE ,1 i c
II
-- , I ' - -
1
ff chimney
7 -
Retain 6x8 beam,
supported by 2x4 1 1 fl ^
wall(see detail l l -L
for opening) I—_ -
\ 1 1 •.\ .i
11, -- — P° — I d —1k 'I1
r.
New 2x4 wall
supporting joists New joist sisters
(blue)
Building Plans are to be printed out with a minimum scale of
Notes 1/4":1' Residential landscape/site plans may be 11"X17" if they are
All new walls are 2x4 except wet walls are 2x6(see detail) legible.
Paper copies of all plans are required to be on site at time of
inspection. Ryan Walters—2/28/2021—pg 2
If suitable, approved plans are not on site, the inspector will not Basement Walls,Joists,Beams,Posts(proposed)
make the inspection. After two failed inspections due to no plans 1803 10th Street,P56056
or inadequate plans, a reinspection fee will be required.
19'-7 15/16"
/
Egress 14'-7 3/16" / 10'-9 3/8"
Window / /
19'-8 1/16" 85.00in. 78.75in.
/ i i
14in. 20in.
i /
tiQF04i CODE c 80.25in. 85.00in. 85.00in. 52.50in.
A
Alik),4,,,Y t" I. •1 I. •i._ _ II• •I I
rri [i r ll [1 r ll ,
rn
�w a,
ce p
r0 FIELD Iti rilo o p
Dryer duct to
outside(E)
C Bathroom 1 Fan Exh Fan
Bedroom 1 Laundry
;11111.i
Fir
5 3 Oin )
. 13'-10"
alloo it Closet/Cabinets Utility Chimney F-IW Stairs to main
` ` ° floor(existing)
fl
@ m•V
CV
® \
Closet c
N J C�i 0_
Bedroom 2 Exh
N Fan Z9
4
a Z9 -cCV
(a c
v m
o b French doors to M
b — outside(existing)
_L Mr
Network
N
`" Closet
11111111li. =
t / t
7 16.00in. 15.00in.
66.75in.
/
15'-8"
19.50in.
1'-4"
9'-1/2" 6,-0
i 60in.
.�
Notes 10.-11 7/8"
/
All joists are 2"x10"at 16"OC;spacing exceptions noted. 66.00in.
Egress
Ceiling height is 7'0"to bottom of floor joists. 7'finished is code, but we will call this close enough. Window
New hot water tank is electric.
Furnace is existing,direct vent natural gas.
Smoke detectors(SD)are hard-wired interconnect with battery backup(First Alert 9120B) Ryan Walters—2/28/2021 — pg 3
Hard-wired interconnect combo smoke/CO detector(First Alert SC9210B)provided in central hallways in basement and on main level Basement Floor Plan (proposed)
All windows are existing openings but expanded for egress windows. 1803 10th Street, P56056
Egress windows are casement 26"wide by 36"height(6.5 sf),and 44"off floor.Window wells with at least 36"projection to be provided.
Bathroom windows are to be replaced with tempered privacy glass.
Existing 1.5"ABS vent for
bathroom 1 and laundry
�QFOR CODE c,0
I" r, .e 1
`1 I -/ � {y2 -_� - 2" — Laundry
LLLRRRtt"'S` V rri r r I Box(E) TABLE 1002.2
l Il HORIZONTAL LENGTHS D TRAP ARMS
2" minimum vent size required (EXCEPT FOR WATER SIMILARCLOSETS AHO FIXTUFiESI'
OiSTANCE TRAP T❑
1n Y4, 1891 w for proposed fixtures. UPC 702.1 2" TRAP ARY PIPE YE HT MINIMUM
LENGTH U.Saim to
\_._
DIAMETER llrlctlrsl (inc rinl
'�COR �` Venting to be comply with 2018 ""`""'
�tO FIELD I'''. UPC. 1 p l'h 3 42i
2 4 00
Bathroom 1 Faxn n 1.5' 3 6 72
4 B 120
Bedroom 1 Laundry I:oceeding4 2xDiameter 120
For SI unn. I inch Z 4 mm
M,33111d1F3',Inch Kr Iexn.hep0 I.'u It nun WI
' The dnrkryxd length Artificer the ua p nl a a Ala.I.nn err SIMI LW fnlure
1 (mcawnd Mint tile top of the clou i diner 10 the Inner cdgc or she,ct11I
and IL.%ern xhall mit exottd ,ittt I I Of minl
C h--3uh
II I __ TABLE 707.2
' 70LxIW141 VHIE LOADING AND MAXIMUM LENGEH OF°RAMAGE ANO MR PIPING
/ Maximo.Foils
3 Oin. Ilrumgc Ihporg
.knxll I 2= 16' aa• 256 630 13R0 3600 SGOO MC
Closet/Cabinets Utility ° • HW Ikn ,.. I 1 .' 3r 11e` 43r 12e• ' OBO' •
MO'
Chimney "��^••1empa
n i tOorripe PII,1110
rl-n1,cal.lr[, 45 03 i5 21'_ 300 390 510 ]50
� `/' 3" 16wn1:d11m1,InnM1
1'..[Yipemy
I�.+nml,l nnel.tn.c40
Manlmlrn L'nns I 8' 14 83 27a Nil 1310 1e00
Mralmim I.44plhi.11441} N NI 120 212 911 390 11n 730
Fo.H.mla I mb-250m,I bee=30L.arue
I P.ddedoe rep len
® !r.ou.k.w-a 14.11.mid ih.•....h.. eundirp I nn[.e nnil
/\ a ExePl'.rwtlk trap,.
�,waro i.......44I,tar, .
'Oaa pm du(n•eIra 41103W.be°ertn1,45ai"uk,Wixi[rurufni ell.•dl.i rl...r1111,1•nni[.n(Feu.ilV1.111ii Mmfh.
7 a ..
s Bg444 in q M per Ma 1'_I!R ree.yn,.Mpr F."'.11.1.I.,11.11a,i.nnla}r./e.4417101.txAxrol bk.,.unl.F,.1 144,4 or0 L
n 1ka1r.n[r or.Ind1.wd.e..Ii.herenrr WI rO.1•.i.,an(1:minin..k44,.unnnry.111he4.mm,•.4Ih.'Olin In;Opt.IInw.erled PI51urc
E
Ya3 Im 010 er
0.a1edrtlM
ram.1•n Ixil&WA Mall i.rp'Aed fr.TIN,7021 Ya.17IR[„12.212,Nee rS e,n(Ri•nca. arY Morme perrana Imelk
Closet • a la.w d.1111rpa.ar. M-.woo:na Annnwl6.6..min,+,,re.xn,norcn.W..h•nlpr,e',0, •n.1111eglh.14mIU14m kV!,1.m.1.5" j 1Woni rp3e31k m v4 r�dk3•.100 1R�4%TT. le 6In ee,v11tt ea .11h A[tepu. m g rn .,-05nr901
N J
Bedroom 2 N Fan _ One option for venting Bath 2 would be
to run fixture venting up to a vent pipe
15' centerline of toilet m . . 1..J„.;11"...,.....I.., in the floor system, and from there up
�) pinrlor,°inl.v,...,,,vng,
to finished side walls, 3" and out. A larger vent stack will be
minimum. �`J required than the single 1.5" stack, or
_L an additional 1.5" vent pipe could be
Network 15n installed.
Closet
Main sewer line
(existing)
Notes
All drains are ABS
All supply lines are PEX
Ryan Walters—2/28/2021 — pg 4
Basement Drain/Vent Plan
1803 10th Street, P56056
Egress
Window
QF04t CODE co
ti A
,.i.i, ciink., -It Eiii Ell II, i4_ __.=_ d
p
N��✓� 4 C O g�891 w`ff
tO FIELD I'5
0
Return Ilk
Exh Exh
Fan Fan
Bedroom 1 Laundry
Utilit
• Furnace• • y Chimne HW
J �� I I
v
m
x /4.
7 ,n7
Closet 9in.x 9in. 0
n
D
Bedroom 2 Exh h
(V Fan
tri
1
CO
Network
Closet
1--1
R310.2.3 Window wells.
The horizontal area of the window well shall be not less than 9 square feet(0.9 m2),with a horizontal projection and width of not less than 36 inches(914 mm).The area of the window well shall allow the
emergency escape and rescue opening to be fully opened.
Exception:The ladder or steps required by Section R310.2.3.1 shall be permitted to encroach not more than 6 inches(152 mm)into the required dimensions of the window well.
R310.2.3.1 Ladder and steps.
Window wells with a vertical depth greater than 44 inches(1118 mm)shall be equipped with a permanently affixed ladder or steps usable with the window in the fully open position.Ladders or steps required Ryan Walters—2/28/2021 — pg 5
by this section shall not be required to comply with Section R311.7. Ladders or rungs shall have an inside width of not less than 12 inches(305 mm),shall project not less than 3 inches(76 mm)from the Basement Ducting Plan
wall and shall be spaced not more than 18 inches(457 mm)on center vertically for the full height of the window well. 1803 10th Street, P56056
Typical flush mount beam/floor joist detail Ryan Walters—2/28/2021 — pg 6
1803 10th Street,P56056
Qcnii LODJ co
�W�� 1 Y OA{9 Double 2x10(up to 44" long)
rn
7111111611t, /
vi.4c18091.9_,c4,,,,6.$
1p FIELD 11•45
/Simpson LU-28 face-mount hangers 2x10 floor joist(E),
cut to insert flush mount beam
Existing 2x10 floor joists Existing floor joists cut and attached
to flush beam with LU-28
I / Double 2x10(up to 44" long)flush beam
)10 X
30" Doorway
Pressure-treated
2x4 sill plate
I I
Typical basement exterior wall detail Ryan Walters—2/28/2021 —pg 7
1803 10th Street,P56056
QFo9 CODE
�9
S�w�'�C) Y OV Simpson Strong-Tie Foundation-Joist Attachment every other joist
rri
1891 PI 2x10 floor joist(E)
�(<6, INA
� 4 Add Roxul mineral wool acoustic
V insulation with air gap to subfloor
Insulate rim joist with 1.5-inch XPS foam and fiberglass
4 1/2-inch drywall
2x4(2x6 in wet walls),with Rockwool Comfortbatt insulation (R-15)
XPS foam insulation (R-7.5);Tyvek taped at seams
41.5-inch
Poured concrete wall (E)
Underslab insulation
not required due to
depth of side walls
below grade.