HomeMy WebLinkAboutPermit File 2809 Grady Lane y �0 Y OF CITY OF ANACORTES WASHINGTON egCOP4� BUILDING DEPARTMENT CERTIFICATE OF OCCUPANCY ' This is to certify that the (Description of Building or Structure): i' Single Fami ly Residence Located At: 2809 Grady Lane STREET&NUMBER ,f Owner: Townes View Prose-ecies ,) Constructed By: Owner OWNER OR CONTRACTOR • Bldg. Permit#: LDP200E`0008 Datelssued: February 26a 2008 Occ.Group: , "' Use Zone: 8-2 Has Been Inspected And Occupancy Is Hereby Authorized. This 8t-h JD/a/y(yf/�off {?//U9US' is / yJ 2009 KUTKoRIZ p OFFICIAL y SEE REVERSE SIDE FOR SPECIAL REQUIREMENTS. 0805704-1 0002 02 26/200;= 002 4 ..t,-yy O Cityof Anacortes Permit Fees 007832 $11,948.25 • O oth Street Permit#: BLD-2008-0008 ' Issue date: 02/26/2008 `� Anacorx s, Expire date: 02/25/2009 �U,t; Anacortes, WA 98221-0547 ,:eitcc, ,r' (360) 293-1901 Job Address: 2809 GRADY LN Permit Type: Single Family Residence Permit ANACORTES WA 98221 Project: APN: P126319 Remarks: New single family residence Owner: TOWNES VIEW PROPERTIES Contractor: Address: 3818 W 12TH ST Address: ANACORTES WA 98221-4534 Phone: Phone: License#: General Information: Fees: Building Valuation 500000 Traffic Impact Fee 900.00 # Forced Air Furnace<=1,000 1 Building Permit Fee 1,433.00 #of Bathtubs 1 Plumbing Permit Fee 174.00 #of Clothes Dryers 1 State Building Code Fee 4.50 #of Clothes Washers 1 Park Impact Fee 615.00 #of Dishwashers 1 Mechanical Permit Fees 125,30 #of Gas Fireplace 2 Plan Review Deposit 100.00 #of Gas Piping 1 Sewer Inspection Fee 50,00 #of Gas Water Heaters 1 Sewer GEC-Residential 6,675.00 #of Water Piping 1 Storm Drain GFC-Residential 1,140.00 #of Hose Bibbs 4 Plan Review Fee 831.45 #of Kitchen Sinks 1 Total Calculated: 12,048.25 #of Lavatories 6 Deposits/Receipts: 100,00 #of Range Hoods 1 #of Showers 2 Total Due: 11,948.25 #of Slop Sinks 1 #of Ventilation Fans 4 #of Water Closets 4 THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CyO�N/S�TRUCTION. SIGNATU'- ••F OWNER OR AUTHORIZED AGENT SSUED BY Final Inspection ChecklistII 1 Site Address: .2 ?( 9 �VQ dy liter /a G Permit No.: (2Y— 600 cr S- Date Issued: 2 .2 6 C g Zoning: X 2- Occ. Group: R 3 Constr. Type:__ 4 Owners Name: St') Qo b ( ©W h Bl7 Owners Mailing Address: State: Zip: Variances: No Yes Y Safety Glass: No Yes 6/ Sewer Fee Paid: No Yes Y Hand Rails: No Yes Sewer Inspected: No Yes , ' Guard Rails: No Yes 1/ WSEC Compliance: No - Yes 6 Traps: No Yes t/ i G Attic Access: No Yes r Stove: No Yes ✓ Smoke Detectors: No Yes 1/7-- Water Pressure: No Yes // T&P Drains: No Yes /— House Numbers: No Yes '-� Insulation Cert.: No Yes_Z Site Drainage: No Yes Curb Cut: No Yes_/rZ • Crawlspace Insul: No Yes IZ Bedroom Windows: No Yes / Water Heater Strp: No Yes 1 Vapor Barrier: No Yes D.W. Air Gap: No Yes Water Meter Box: No Yes (/ Auto Garage Door: No Yes t9 Exterior Decks/Landings: No Yes V • Outside Caulking: No Yes Garage/House Door: No Yes v Inspected By: g / Crawl Space Access: No Yes c/ Date: c� 1q6 O Exh. Duct/Dryer Vent Dampers: No_ Yes v �� UI �Gl INSULATION CERTIFICATE A & E Insulation, Inc. 15205 39th Ave NE Marysville,WA 98271 (360)651-1058 Ebb I dton-e-S Contractor-Builder/Homeowner's Name &soil t;,irad14 En ADDRESS 101 ear itt Vat- W. 1 CITY STATE ZIP RECORD OF INSTALLATION BLOWING WOOL BATTS AND ROLLS AREA ❑ NEW CONSTRUCTION IF RETROFIT: R-VALUE THICKNESS INSULATED �y f IN )-IN1 u-� SQ FT ❑ RETROFIT CEILINGS-�rl- DEPTH OF PREVIOUS IN /_�_.SO FT NUMBER OF BAGS USED INSULATION IN WALLS 02 I -I'J1 JZ IN p�j5SQ Fr AREA INSULATED ESTIMATED R-VALUE OF SQ FT PREVIOUS INSULATION _ IN SO FT THICKNESS OF INSULATION TYPE(S)OF PREVIOUS FLOOR IN SQ FT INCHES INSULATION IN ATTIC IN SQ FT R-VALUE OF INSULATION INSULATION CONTRACTOR SIGNATURE DATEGQ /1/3 / HOME BUILDERS SIGNATURE /% / DATE // COMPANY /26;,-Q tat / PHONE j; gi 7/ ADDRESS A&E Insulation, Inc. does guarantee that all work performed is free from defective material and is constructed in accordance with sound construction standard, in a workmanlike manner in compliance with all laws currently applicable to the work. In addition, we guarantee to repair or replace any or all of the work and/or material which may prove to be defective in workmanship and/or material: except for ordinary wear and tear and unusual abuse or neglect for a period of one (1)year from Date of Substantial Completion. .; ' . uiiiic V rks .. Engineering and Development Services • Residential Inspection . Address; z5BOq _ Q,4�.O Li:\t, Date, I Or Iwne io LOa `z iCi�w iLi � k.1 Q `-� Contractor \\ Inspected,by:; .3-‘ W\ .•2CJIwtsbk.h)iuc. III 1. Water Meter Box • vj-'Set,firm and level to finished grade or backside of sidewalk elevation. El..-Lid-find box undamaged: [Z --Water meter and customer shutoff installed. , [2-�ta-aelis: ®--Asible=no landscape obstruction.' [j Driveway installation has dnve over box and lid. tourer gate;valve intact. at+.;;t%'1eatcs at cor hectwns. . 2. Curb and Gutter crack darriege, graffiti footprnnts,;'r shing blernishes, or other objectionable Markt. K'4:1. __ - h ih If road frontage improvements:, o Expansion joints euety is feet and at driveways. 0: 'Concrete_has broom finish:'; No loiotip4t,atcurb line, especially at driveway cut Maximum grade change in 20 feet is.%inch , 3. Sidewalk., EziA46 cracks,damage,graffiti, footprints finishing blernishes, or other objectionable _ m ADA compliant 7 1 percent slope to curb. • If road frontage improvements: 0. :.axpansion loin*.every 15'feet and at driveways. . 0 Concrete has broom finish • 4. Driveway Approaches Oer9cks damage, graffiti, footprints, finishing blemishes, or other objectionable [DADA compliant • • • •6: Streets . I v ` (] No,cracks,Iblemishe : - - If read or alley improvenents: . - • - (] "R ed proctor and sieve analysis of ballast,crushed}odc; and asphalt. Q •• Received passing'nalenals testing reports for sub-grade,•hafast� eryshed rock, and asphalt: • Received tonnage tickets consistent with required thickness•'per approved: Plane. • 6. Sanitary Sewer' nspectwn card signed off and/or verified in Building Department database.; • [r� built record fled in the address file: - • : crew cap(s);installed on dean-out(s). • tears-puts)set at finished grade:- 7. Storm Drainage nspectien card signed off and/or verified in.Building_Department database. s$uilt record filed in address file. ( . t4otblocked or: diverted to adjacent parcel: • 8, Public Utilities Qut^of teaveled Way r A Q Concrete collars around City•utilities. - 0 Final gmdtn9.ok [] Restored to prior condibpn or better:" 9. Lanctscape C.0 c rr r' ' Q Bonded for completion',at later date. Verified against approved landscape plan. staliatt4,n . ❑ Tape and quantity of plants. • • o Sod or seed in place: (toot barrier(receipt filed). • 10. Erosion sIMeasures ( r Bi4Ps removed O''Altdebtis removed; Site dean. • [L ?etrnanent vegetation established. - ` t I Curtis Associates LLC. Consulting Engineers 1004 Commercial Ave PMB 311 360 299 0419 Anacortes,WA 98221 fax 588 8869 curtisassoc(cr),earthlink.net June 27,2008 Project name: 2809 Grady Lane Project number: 07-106.00 Project Location: 2809 Grady Lane Anacortes Wa,98221 Subject: Project structural observations and closure As engineer of Record for the above-mentioned project Curtis Associates performed several site observations reviewing progress and current work completed. Several structural observations were made periodically during construction this included 3 site visits along with several unofficial visits.These were not inspections of the work being completed only observations of the progress and quality of construction. The work was observed to be in general conformance with the structural portions of the contract documents. To the best of our knowledge,all identified items have been resolved at this time.This letter does not constitute a detailed inspection,nor does it replace the requirements of a final inspection by the building official. Items noted by the building official,as part of the framing inspection will be addressed in addition if any are required. Please call if there are any questions or comments. Thanks Quinn Hanks. cc:Gary Curtis, Pat Rooney,Bob Townes,Cynthia Richardson Attachments Site observation reports 1 to 3 Curtis Associates LLC. Bob `1004 Commercial PMB 311 2809 Townes Anacortes Wa, 98221 Grady Lane Anacortes wa 98221 Site Observation Report Project# 07-106.00 To Cynthia Richardson Date 3/18/2008 8:36:32 315 v Anacortes Wa 98221 Time start 4:00 PM Time finish 4:45 pm CC Cynthia Richardson, Gary Curtis, Bob Towns, Weather 40 Sunny Pat Roney Project current state Reinforcing for retaining wall is partially in place Architect Cynthia Richardson Architect Contact# 299-9081 Also Pat Roney, Bob Townes Hard copy: Will not follow Present: Observations Report#2 NEW Items Item 2.1 The 1" DIA anchor bolts at the top of the retaining wall were evaluated for site conditions and modified per attached sketch #4. Item 2.2 Along Gridline "F" at grid 6 the detail 8/S6 indicates a 3'-6" max opening. At this location the opening can be modified to a 6'-0". Action taken: An 18" minimum depth of header will be required for this change, in lieu of the 12" detailed on the plans. Item 2.3 Along gridline "F" at grids 9 to 10 an additional shear wall was added. See attached sketch #5 for revised shear walls and holdowns. Item 2.4 At interior shear walls per detail 9/S6 an alternate epoxy holdown was requested in lieu of a sstb bolt. Action taken: Using a 7/8" DIA threaded rod in simpson SET adhesive with 11" minimum embedment will provide an adequate uplift capacity. An additional #5 bar will be required at the top of the footing. The depth of the footing will require 14" to maintain 3" clear below the threaded rod. Curtis Associates LLC. Bob Townes `1004 Commercial PMB 311 2809 Grady Lane Anacortes Wa, 98221 Anacortes wa 98221 Site Observation Report Item 2.5 At 3x plates a sstb anchor will be allowed. Action taken: This will require an additional coupler and threaded rod extension at the holdowns. Items noted above were discussed with the contractor. Please call if there are any questions or comments. Several digital photos were taken and will remain part of the digital file. Regards Quinn Hanks Curtis Associates LLC. Bob Townes 1004 Commercial PMB 311 2809 Grady Lane Anacortes Wa, 98221 Anacortes wa 98221 Project it 07-106.00 To Cynthia Richardson Date 3/11/20088:36:32 315 v Anacortes Wa 98221 Time start 6:00 PM Time finish 6:15 pm CC Cynthia Richardson, Gary Curtis, Bob Towns Weather 50 deg overcast Project current state Forms for spread footings have been placed Architect Cynthia Richardson Architect Contact it 299-9081 Site Observation Report Also Hard copy: Will not follow Present: Observations Report#1 NEW Items Item 1.1 At several locations the step in foundation is greater than the 2'-0" maximum allowed per detail 2/S6. The current steps in foundation have been reviewed and are in general conformance to the contract documents intent. No exceptions taken at this time. Items noted above were discussed with the contractor. Several digital photos were taken and will remain part of the digital file. Regards Quinn Hanks Curtis Associates LLC. Bob11004 Commercial PMB 311 2809 Townes Grady Lane Anacortes Wa, 98221 Anacortes wa 98221 Site Observation Report Project# 07-106.00 To Cynthia Richardson Date 3/18/2008 8:36:32 315 v Anacortes Wa 98221 Time start 4:00 PM Time finish 4:45 pm CC Cynthia Richardson, Gary Curtis, Bob Towns, Weather 40 Sunny Pat Roney Project current state Reinforcing for retaining wall is partially in place Architect Cynthia Richardson Architect Contact# 299-9081 Also Pat Roney, Bob Townes Hard copy: Will not follow Present: Observations Report#2 NEW Items Item 2.1 The 1" DIA anchor bolts at the top of the retaining wall were evaluated for site conditions and modified per attached sketch #4. Item 2.2 Along Gridline "F" at grid 6 the detail 8/S6 indicates a 3'-6" max opening. At this location the opening can be modified to a 6'-0". Action taken: An 18" minimum depth of header will be required for this change, in lieu of the 12" detailed on the plans. Item 2.3 Along gridline "F" at grids 9 to 10 an additional shear wall was added. See attached sketch #5 for revised shear walls and holdowns. Item 2.4 At interior shear walls per detail 9/S6 an alternate epoxy holdown was requested in lieu of a sstb bolt. Action taken: Using a 7/8" DIA threaded rod in simpson SET adhesive with 11" minimum embedment will provide an adequate uplift capacity. An additional #5 bar will be required at the top of the footing. The depth of the footing will require 14" to maintain 3" clear below the threaded rod. Curtis Associates LLC. Bob Townes 1004 Commercial PMB 311 2809 Grady Lane Anacortes Wa, 98221 Anacortes wa 98221 Site Observation Report Item 2.5 At 3x plates a sstb anchor will be allowed. Action taken: This will require an additional coupler and threaded rod extension at the holdowns. Items noted above were discussed with the contractor. Please call if there are any questions or comments. Several digital photos were taken and will remain part of the digital file. Regards Quinn Hanks ;1 \ \ / ^ 7/ ,p / i V. o tiO4, i 1,0 / A"40 /11 \ /tttti \ / Cr 111111 zt / 1. \ / A )7 4\ / ‘a 'Sp2 AN tie � AP � CO' _0,a �o 0 SKETCH 5 1 DATE:MARCH IS. 2008 MCXIIECT STRUCTURAL MIE R ms hResi re A MmHg ,AueR rem JOB NO: 07-106-00 DETAL PAGE has a ten w 2809 GRADY LANE 2 of 2 mama slan AFFECTING MACOMB WA SHEET NUMBER PARTIAL 2ND FLOOR PLAN N/A 0 0 0 sareeiroc © a sw¢°arcc woe:roc +.... I 0 0C WOROCIONO.' OG W/9lOCl0!(+Ob'OO I I o - iSsflimIll III — OP M�c1b® / ' F` 1 API \ \ I —\ it ) ) c 4 \ 4 g4 , C \N -\1/. _1( ^=.._ ice\\ e\(se \w1 / 8 ro' 0�o' , Ick..% / it. \ .\\\.\ ...„ 4 \/ V. �� �, CS 0 / C4 % _\ \ / . I 4 © SKETCH 4 G DATE:MARCH 10, 2008 ARCFNECT Write A tatur.a Romig Cab tajorliatiLER JOB Nth 07-106.00 OEQL PACE 70 VAS 1a60moY An NONI 1 Of 2 saws a UM haft'wEel 2809 GRADY LANE310-2111-11.1 AFFECTING ANACORIES WA SHEET NUMBER ANCHOR BOLT LAYOUT N/A I. . I Curtis Associates LLC Anacortes Wa, 98221 FAX/E-MAIL 1004 Commercial PMB 311 To Cynthia Richardson Project# 07-106.01 315 v From Quinn Hanks Anacortes Wa 98221 Project name 2809 Grady Lane Date 6/3/2008 10:57:55 AM Contact# 299-9081 Subject Fax# 299-9081 Shear walls @ gridline 6.5 & 8 cc Gary Curtis, Pat Roney, Bob Townes Pat: As discussed on site. At Gridline 6.5 A W3 shear wall was called out with detail 5S9 for a holdout at the base of the wall. At the contractors request an alternate solution of using a PHD2 holdown with a threaded rod and plate washer will provide adequate load transfer. The plate washer on the bottom side of the beam will need to be a minimum of 7 square inches of contact area between the plate and the bottom of the beam. At the plate a minimum depth of 10" will be required at the beam allowing for a maximum recessed depth of 1-7/8" . On sheet S4 detail 7/S10 at gridline 8 detailing the shear wall to roof connection has been modified. At the contractors request a truss was located along gridline 8. The truss will provide the drag strut required for attachment from the roof to shear wall below. At this location additional A35 clips or LTP clips will be attached at the bottom chord of the truss to top plate of shear wall. Spacing of these clips is per the shear wall schedule for a W6 wall this will require A35 clips @ 16" oc or LTP clips @ 24" oc. Please let me know if there are any questions or comments. Thanks Quinn. urtis Associates LLC. Bob Townes 1004 Commercial PMB 311 2809 Grady Lane Anacortes Wa, 98221 Anacortes wa 98221 Site Observation Report Project# 07-106.00 To Cynthia Richardson 315 v Date 5/3/2008 8:33:55 Anacortes Wa 98221 Time start 7:30 AM Time finish 8:30 Am CC Cynthia Richardson, Gary Curtis, Bob Towns, Weather 40 Sunny Pat Roney Project current state interior wall framing has been started at lower level Architect Cynthia Richardson Architect Contact# 299-9081 Also Pat Roney Hard copy: Will not follow Present: Observations Report#3 NEW Items Item 3.1 Along Gridline "F" at 6.7 references Detail 9/S7. This can be modified to include a L4X4X1/4 X 6" long angle At the beam See attached Sketch 6. Item 3.2 At gridline 1 ,A and 1,F the PHD5 holdowns were not installed due to site conditions. The P.T. sill plate installed vertical at the end of the concrete wall will provide adequate holdown capacity. This vertical sill plate can be tied to the shear wall using A35 clip @ 12 in oc. See attached sketch 7 & 8. Item 3.3 at Detail 5/S9 in lieu of the upside down HHDQ11 holdown. See Attached sketch 9. A CMSTC16 strap may be located at the beam. At the foundation support of this beam an additional holdown and simpson strong-bolt wedge anchor will need to be located at the foundation. The anchor will need a minimum of 5-1/8" embedment into the foundation. Item 3.4 At Detail 8/S7 the drag strut element the CMSTC16 strap may continue over the sill plate already installed and nailed to the sill plate. End length wilt:require the strap to continue 25" past the start of the sill plate. If splitting of the sill plats is a Curtis Associates LLC. Bob Townes 1004 Commercial PMB 311 2809 Grady Lane Anacortes Wa, 98221 Anacortes wa 98221 Site Observation Report concern use 50" end length and fill every other hole in the strap. Item 3.5 Typical at all shear walls a 7/16" struct I rated sheathing may be used in lieu of the 15/32" called for on the plans. This will require a closer nail spacing than originally specified. A W6 wall will shall be nailed at 4" oc. The W4 walls will require nailing at 3" oc, and the W3 walls will require nailing at 2" oc. There were no W2 walls called out on the plans. Items noted above were discussed with the contractor. Please call if there are any questions or comments. Several digital photos were taken and will remain part of the digital file. Regards Quinn Hanks li lil SHEARWALL EDGE AT CONTRACTORS OPTION LS90 CLIP NAILING MAY BE LOCATED PRE-DRILLING MAY BE ON OUTSIDE OF REQUIRED CORNER PLACE IF RIPPED BLOCKING LONG LEG OF CLIP SPLITS ON RIPPED 2x ,.�''` STUD 116 j� (7) EA SIDE (14) J TOTAL A35 CLIPS OR (5) EA SIDE (10) TOTAL L90 a a CLIPS PLAN SKETCH 7 DATE:MAY 4,2008 necxnccr smucrunu EucINEw NO 07-106 00 DETAIL PAGE 315 V san Architecture & Planning LLr4s Associates 2 of 4 315ed.IP 1001 Wmedd tee PIB 311 rw emsl At rasml 2809 GRADY LANE AFFECTING ANACRR1ES WA SHEET NUMBER NEW DETAIL S2 —V"— -n- 6" SOLID a • BLOCKINGF �,,,/ ,,,, ,,,, /77/ //// //// //// ////} jr EA SIDE AT • HOLDOWN • i - SIMPSON CMSTCI6 STRAP EXTEND 6" OVER TOP OF BEAM OR USE MSTC48B3 STRAP � USEy PHD2, HDU2 OR HTT16 ae —et— BASE OF POST W/ 5/8"0 SIMPSON STRONG-BOLT , x WEDGE ANCHOR 5-1/8" MIN EMBEDMENT IN CONCRETE SEE DETAIL 5/S9 FOR INFORMATION NOT SHOWN HERE SKETCH 9 DATE:MAY 4,2008 "�`"°=M slam u'�"F" JOB Nth 07-106.00 DETAIL.TACE 31cMNsoo Architecture Harming a Associates 4 mt 4 hpWi° k.aV es.,. tmr Me"e 31 2809 GRADY LANE "-`" ' "a °° "�' AFFECTING mo-z�mei ANACORIES WA SHEET NUMBER NEW DETAIL S7 SHEARWALL EDGE NAILING MIN PENETRATION INTO ��►== VERTICAL WOOD SILL PLATE IS 1-1/2" SHIM SHEATHING AS REQUIRED a a PLAN SKETCH 8 DATE:MAY 4.2008 ancximn smuciui acwl�a 315V son Mdritecture&Planning cubs Msodutes NO: 07-108.O0 DETAIL PAGE 315 V Mon laol COMM M P18 3tl 3 of 4 a�z1 �,a 88221 2809 GRADY LANE AFFECTING ANACORIES WA SHEET NUMBER NEW DETAIL S2 2" ►, (2) 4"0 A307 THRU BOLTS arti CN ewe" • z.,t, ► 1 4 SIMPSON STRONG-BOLT WEDGE ANCHOR 113 WITH 4-1/2" MIN EMBEDMENT L4x4x4x6" SKETCH 6 DATE:MAY 4,2008 ARCNNcCT STRUCTURAL ENGINEER DETAIL PAGE RIchmdson Architecture& Planning Curtis Associates JOB NO: 07-106.00 1 of 4 313 V Mena law ' M PillPill311 2809 GRADY LANE 9 Mixable. "°mt�aB9B'� AFFECTING " ANACOR1ES WA SHEET NUMBER NEW DETAIL S7 BOISE BUILDING MATERIALS DISTRIBUTION Sheet ""et- of Engineered Wood Products Job: 'n s Lett -/4-4J 8720—216th Street SE PO Box 168 Woodinville,WA 98072 Location: 2 go, genr-by L Ate se, h4'O D j Tel. 425 486 7477 800 342 2299 Fax: 425 402 1567 Date: y q— ! -zao$ war , I — I_ �_--� i L i I II __ I -- 1 r 3 II � I i 1 I I ,k, j.. 4 i I ' �—y Pt • 1 r' 4L. �y �— I --- — - - -- - --- - • II - - -- I A ' i- � I Z?e --- - --- I ICv I , , , i j ' ' ! I i ' I , � l 1 __ 1 1 _ JI 1 1 I 1 1 1 r ! r I , is _ - I . 7 4 : - ,e i j I e r I i - - I I� I I I 11 1 I I , I L I I -- - - - , I I 1 1 , I I 1 ! 1 I N I I i wlj Esi- i I !� - BCI° Joists, VERSA-LAM® Beams BOISE' Wof "to 5ca/C- and BOISE GLULAMTM Beams p . j • • * 4`--...' '� , rV 'bra i.p ' j It ^4 l Yr' - No....4.4.t.:\01:0:14.4140044611i.. "."''.'..,f,'‘!. ', ;' it '', ' • . t . y , --. - j'it r k '' s o+ - ,• i 2 It I. i. lir IINSOP- 4 k + .;� -.N . , or )11 ),,mi• .,., ,, t .. ',pelf.. it • A: .. . , ' , ;. a -, .. . , . . ,.., ... .. , , . . , - . -..,4, - 7.„ , .. • ,' ,, .._. .1.4116miumimusim...._ .._ 1 ''''''.__ 7r.: a to .. , dr _t" , li ol 3 C.. . .._ ' 4 1 i , .. .� "� , r ! 4 i ♦lN i d'. , 440r� ?s ' i r ............ • 4, �ii .. . R 5 V1 E+—� r mi'�-1 eS 1BOISE BUILDING MATERIALS DISTRIBUTION '�ow+ Sheet of ` Engineered Wood Products Job: 8720—216th Street SE PO Box 168 Woodinville,WA 98072 Location: 2401 ehooty L..4Nt— Tel: 425 486 7477 800 342 2299 Fax 425 402 1567 Date: it /3/2-01:,2 E y„ I pep S itriatir �j",^ ,, 1-- , -4*Inti ; 1 , , : TNetr_H If.i ; ! ' ; ; * ' I • (44 1 7 ; — `1 L- j l F N 1 6, 1 `\ I, i ' , . — ' -j -i- / , �1-1— f -II - �) 'f .D4.,^Jg, ! k I L., c t_ J , { ' 1 . 1 I ' SI 1 ' L H y Fr eli _ I mr /1}1 ±- TO Sca je, BCI® Joists, VERSA-LAM® Beams BOISE' and BOISE GLULAMTM Beams w ir 141 S.! ►',4k 1 A ' * . a'M _ (-)Q cen q —(alb .n /\ I ) .4 .A )G •-rf,7 1/ 1 J1' Cr-) Lt Tl eh Y�—� „ • (1-) 7 Cs �,C; r r5 V\ v I ,n ,, Pin') 1 )D OWL) CC\dz -eCTib(h.-� • tl • f J TR. Y r 11/ • toe by n • L ' s 111.** ♦ # ' BM 1 �� rr • . ! /! /'\ C*0 !"•.n n ,n I) % Y1 .. 1 �•. -+�/',In i.,n Ran .. _\ ! ✓_ ,_ .n1G„'T.1 t, 1 c rair 00* •4' 414144Ly ' 77) A • a y t # % 7 `�. rr • • 11111A- • • CITY OF ANACORTES BUIDLING DEPARTMENT RESIDENTIAL t CHECKLIST (This form is to be completed prior to issuing the building permit) Site Address: a�f'ock v'^a� y LQ e Date: r/ i /(99' Contact Person: _4o Phone No.: Assessors No.: P 10)'t.9 3k q Lot: e Block: Addition: “n w' (Building Department Checklist for Completeness) OK NA OK NA ❑ Fire Department Access ❑ ^ ❑ Fire Hydrant Located within 250 feet ❑ Fire Flow Required ❑ ❑ Shoreline or Wetlands El Site Plan ❑ 0 Covenant Approval ❑ Variance Required ❑ ❑ Regulated Slopes ❑ Plat Facts and Findings Compliance El ' ill Survey in File ❑ Fill on Site Received and Reviewed by: Date: (Engineering Department Checklist for Completeness) OK NA OK NA ❑ ❑ Water Extension/Meter ❑ ❑ Sewer Extension/Connection O 0 Street Improvements/Sidewalks ❑ 0 Site Drainage Plan ❑ ❑ Covenant Not to Oppose Future LID 0 0 Latecomers Agreement ❑ 0 Street Drainage ❑ 0 Driveway location,slope, culvert ❑ ❑ Storm Drain Extension ` Received and Reviewed by: Date: 6 FURTHER COMMENTS Zoning: 0/ 17 Lot Size: cg C3 co `S 1 Coverage Allowed: ,-,-5 Yt sF / 3 S o Q Cc--- a R 3 Actual Coverage: I . r.�;n r� 1 988 Sr p - 1 ; LowA FWT j, y-)04 iP r 94 E [r; F'` r.� •: _ r Mr o ,AIB a i rt„a-aa -- -4,a.s-zs Sr+ € id . _ ; f c®.um is Dcu e� 9 1,1 ., 34 rota.TOT AREA i �� 19�0r S{'— +V !-I v 2 L::i.f j .ftte Hi =r� \ %' - i 'Y LANDSCAPING PLAN 1`- ---- BBL.65S4 Yn ER SIZE.IA56 BF B %� " li' `\ / •TREES MST BE BLARE / W CFL¢IE9 TO BE FIN C CAUPEle ZOTSR:, / ' �� nR 3 BEES UST BE EvmOR®i bed-- li .i \\ _ _ �,wmbroeE nNTa b� yea Mai ADJACENT ROBES IS A ra51123EIa yaRIETIES REELIED 10 BE LEPER is'Ley IK -C I --r --,- ` sc — I=,IF N. I ,RRm.RT_ _ \-R e( GaBETT-gYaS I I \P \ Aii:iw.NTse Fay -iae I j- \, ".a. Ex ca BE - BED +j <y. <� AERATED AT IBM aB PWRRY I1 1 i'% 9 MILT'AND GICISM11A192 PI AA 1 I na\ To,AL ioxvie sae s �i I APE ...BlASF s1 z,s.0, 6 \ STORM Se cater ALL I nricAL ♦ oce115PO T6 AND _.&.cool BRABRAINSe mLNER '1 i TO STOWS' RATTER-CPeSLf TO CT'WATER SANRARY WIER.COMELY To d I \\ -E�EEvEL 1 I PP Saz g j 2009 - •P LANE J BA�Terr CO a: AT I/ LREER EV. -ECE - I I \ 6—.N.BEE,Eae,R 6 TREc Q, `{ a EM WEL Ta 6TRA1 nTrerE+SS ANTS?To\ . SIGB4LK 4W.PE RH+4RrD UPPER WARE!EET E ,cc F^ln�l. a anon IS Ea RooR `, h. 1 I I i i .RR.ARD i { ,pr tID PLANTING.BEM j _ U1 o0v®4 TurkBR6B \ i�� f1r Bata-8,5 cod `\� as urnw NV,/ /IN — httuwa� low, a l�D'SF ' ' / 140 SITE PLAN /1 etas Ixr.ta• 7 CsRADY LANE yam\ -c �' - soa-go�P.f AREA WEIR 455R 1 VP:21T, Radiant Heating Design Summary Job: t7.'�o1 ��. Date: Jan 10,2008 By: Michael Drake Ram Mechanical Inc. 20253 Cook Rd,Burlington,WA 98233 Phone:707-0112 Fax.757-1449 Email rammechanini@cleamnre.net Web:W W W rammechanical.net Project Information For: Bob Townes a!fay , / 60 (.� 3818 West 12th St,Anacortes, WA 98221 j M� Phone: 588-0374 Design'Information I Total floor area: 3206 ft2 Design temperature: 21 °F Radiantly heated area: 3045 ft2 Maximum supply temperature: 108 °F Total panel area: 3023 ft2 Total flow rate: 13.14 gpm Total tubing area: 2986 ft2 Maximum head loss: 28.27 ft H2O Total room load: 42319 Btuh Total tubing required: 3719 ft Total panel output: 41621 Btuh Total supplemental heat: 698 Btuh Zones 1, Loops 17, Manifolds 3,Actuators 0,Zone Pumps 0, Total back loss: 23714 Btuh System Pumps 1, Mixing Valves 1, Injection Pumps 0 Boiler output required: 66034 Btuh Space Heating Information Room Air Room Supp. Panel Tubing Surf. Deliv. Panel Back Room name area temp load heat F/C area area temp. temp. output loss (ft') (°F) (Btuh) (Btuh) (ft') (ft9 (°F) (°F) (Stub (Btuh RP) /ft') Mutti Purpose Ro 348 68 3813 0 F 335 332 74 94 11.4 1.0 PR 37 68 45 0 F 37 36 69 71 1.2 0.1 Room9 3 68 4 4 Bedroom 3 230 68 2017 0 F 230 227 72 88 8.8 0.8 Bath 2 134 68 695 0 F 134 132 71 80 5.2 0.4 Bedroom 2 242 68 2506 0 F 242 239 73 92 10.4 1.0 Meth 101 68 519 519 Hall 172 68 845 0 F 172 168 70 79 4.9 0.4 Llving,Dining,K 1014 68 18005 0 F 1014 1005 77 100 17.8 11.3 Closet 147 68 1420 0 F 142 140 73 88 10.0 11.3 Space 10 68 175 175 Bath 1 113 68 1522 0 F 113 111 75 92 13.5 12.2 Bedroom 1 391 68 7015 0 F 391 387 77 100 17.9 13.8 Office 99 68 1202 0 F 99 97 74 90 12.1 9.2 Utility 118 68 2536 0 F 115 113 79 108 22.1 18.5 Pnty 17 68 0 0 PR 1 29 68 0 0 Totals 3206 42319 698 3023 2986 Hydronic Devices Device Name I Device type Load Flow Head S/R tubing SWT SWT ll (Btuh) gpm) (ft 120) or Size,Cv Req.('F) Spld('F) Uponor System Design Software 6.0 80 RSRUPN48182 2008-Jan-14 13:55:58 C.\My Documents\Uponor\Template\Townes 01.np Cato=MJB Onentalion=SW . r;1-^4!6 a"1 it -yr.- .i (i11 lii ;I:.], t" s. r;li RAMMechanical Inc. Job: townes01 L�®., �e,a BUllding Analysis Date: Jan 10,2008 Entire House By: Michael Drake Ram Mechanical Inc. 20253 Cook Rd,Burlington,WA 98233 Phone 707-0112 Fax.757-1449 Email:rammechanical@cleavare.net Web'www.rammechanical.net Pro'ect Information For Bob Townes .2fC9 7 , / Z_ _ 3818 West 12th St., Anacortes, WA 98221 Gn r / Q� Phone: 588-0374 Desi• n Conditions Location: Indoor: Heating Cooling Bellingham, WA, US Indoor temperature(°F) 68 72 Elevation: 157 ft Design TD (°F) 47 4 Latitude: 49°N Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gdlb) 17.9 11.7 Dry bulb (°F) 21 76 Infiltration: Daily range F) - 17 ( M ) Method Simplified Wet bulb (°F) - 64 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btuh/ftx Btuh %of load ' Walla Walls 3.1 8030 9.4 Glazing 40.9 20921 24.6 Hy& Doors 18.3 5342 6.3 Ceilings 1.2 2355 2.8 a_ Floors 0.1 219 0.3 Infiltration 1.8 6319 7.4 Ducts 13391 15.7 Piping 23714 27.9 Humidification 0 0.0 ooB Ventilation 4739 5.6 °°l„ Adjustments -876 Total 84156 100.0 Coolin• Component Btuh/ft2 Btuh %of load Walls 0.0 0 0.0 Glazing 0.0 0 0.0 Doors 0.0 0 0.0 Ceilings 0.0 0 0.0 Floors 0.0 0 0.0 Infiltration 0.0 0 0.0 Ducts 0 0.0 Ventilation 0 0.0 Internal gains 0 0.0 Blower 0 0.0 Adjustments 0 Total 0 0.0 Overall U-value= 0.092 Btuh/ft'°F Data entries checked. Uponor System Design Software 6.0.80 RSRUPN48182 2006-Jan-14 13:55:59 C'My Documents\Uponor\Template\Townes 01.rrp Caic=MJ8 Onentation=SW Page 1