Loading...
HomeMy WebLinkAboutPermit File BLD-2020-0760 3518 W2nd Street 1 City of Anacortes Invoice/Permit#: BLD-2020-0760 904 6th Street Applied date: 12/04/2020 P.O.Box 547 Issue date: 12/08/2020 _� t►�: Anacortes, WA 98221-0547 (360) 293-1901 Expire date: 06/06/2022 Job Address: 3518 W 2ND ST Permit Type: Single Family Alteration/Repair Permit ANACORTES WA 98221 Project: APN: P109011 Remarks: FINISH/COMPLETE DAYLIGHT BASEMENT,ADDING A BATHROOM. Owner: PAUL DEMMON Contractor: TBD Address: 1004 COMMERCIAL AVE Address: PMB#591 ANACORTES WA 98221 Phone: (360)739-8007 Phone: License#: General Information: Fees: Building Valuation 30000 Building Permit Fee 442.25 Occupancy Group it-1 Plan Review Fee 287.46 Basement Square Footage 844 State Building Code Fee Resi 6.50 #of Hand Sinks 1 Mechanical Permit Fees 30.75 #of Water Closets(Toilets) 1 Plumbing Permit Fee 41.00 #of Showers 1 Total Calculated: 807.96 #of Ventilation Fans 1 Deposits/Receipts: 0.00 Total Due: 807.96 The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and examined this application and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY t /CITY OF ANACORTES PLANNING AND BUILDING DEPT: a m APPROVED PLANS jd design REVIEWED FOR CODE COMPLIANCE 46'-0" PERMIT#: BLD-2020-0760 / / ADDRESS: 35181 2nd 16-5 I/2" 29-6 I/2" APPROVED BY: L JIM DUNLAP (360) 982-0535 / / / SUBJECT TO FIELD INSPECTION.APPROVED PL S SHALL NOT JIM@JDDESIGNDRAFTING.COM 8' 3 I/2" 5' 11 1/2" I 2'-11 1/2" 12' 4" BE ALTERED WITHOUT AUTHORIZA ON. / / I / / / 8'-2 3/4" 8'-2 3/4" 2'-6" 3' 3" 2' 6 1/2" 3'-5 1/2 2'-6" 5'-11 I/2" 6-4 1/2" Full building plans originally ENERGY CODE NOTES / / / / / / I / / / / submitted under BLD-2017-0648. • CONTRACTOR TO ADD ADDITIONAL FRAMING OR LINE OF CANTILEVERED BLOCKING AS REQUIRED TO MEET CURRENT ENERGY FLOOR ABOVE t / 15' 0" 14 6 1/2" / CODE REQUIREMENTS. 1 AIR LEAKAGE. SOLE PLATE IS TO SE CAULKED OR GLUED TO FLOOR. RIM JOIST BETWEEN STORIES TO BE r. CAULKED/SEALED. ALL HOLES IN BUILDING ENVELOPE .13 m m 6 m ARE TO BE CAULKED/SEALED INCLUDING BUT NOT 3356 CSMT 3356 PIC 3356 CSMT s" +g r" LIMITED TO ELECTRICAL, PLUMBING ; HVAC W- ':.\\ N , , '‘%\ J� A PENETRATIONS. OUTLETS, SWITCH BOXES AND RECESSED FIXTURES ON EXTERIOR WALLS OR CEILINGS JAOSi; ARE TO BE CAULKED/SEALED WITH APPROVED LOWER DECK m SEALANT, OR HAVE FOAM GASKETS INSTALLED. ALL RECESSED LIGHTS ARE TO BE IC RATED, AIR TIGHT m SEALED TO SURROUNDING GWB. ROUGH OPENING �4 AROUND ALL WINDOWS ; DOORS TO BE SEALED/CAULKED. • ALL CEILING EXHAUST FAN DUCTING TO BE INSULATED 3056 CSMT 4016 SL 2956 CSMT 2956 PIG 2956 CSMT AS PER CODE, TO HAVE AS FEW SENDS AS POSSIBLE, .0 il ,.\\ \,\---------)1 AND TO TERMINATE AT THE EXTERIOR OF THE BUILDING. • INSULATION TO FILL ALL EXTERIOR WALL CAVITIES. DO LI NOT COMPRESS. CUT TO FIT AROUND WIRES, PIPES 42" TALL PONY WALL 3' X 5 ��- FEB ► OUTLET BOXES. SH+.ER N • ALL HVAC DUCTS INSTALLED OUTSIDE THE HEATED Q HABITABLE SPACE TO HAVE SEALED JOINTS, CORNERS EX. w a �, Ct BOOTS, AND INSULATED IN ACCORDANCE WITH WSEC FA'' p in 2015 EDITION SPECIFICATIONS ("WSEC 2015"). w REC ROOM ,p 0 • A ONE PERM OR LESS VAPOR RETARDER CIE: KRAFT BATH 2 (DO PAPER, PVA PAINT, ETC.)IS TO BE INSTALLED ON THE LU _ _ 6'-0" 10' CEILING HT. THROUGHOUT - s BEDROOM 2 WARM SIDE OF ALL INSULATION. w GI ," — — 0 •• ALL RECESSED LIGHT FIXTURES IN THE THERMAL ct �' ii ENVELOPE TO BE CERTIFIED UNDER ASTM E-283 AND J PARTIAL FURRING m 3-6° OPTION AT CRIPPLE o n SO LABELED, OR SEALED AROUND THE EXTERIOR IN AN WALL o PARTIAL FURRING - APPROVED MANNER TO BE AIR TIGHT. < / LINEN - OPTION AT CRIPPLE WALL • ALL WATER PIPES IN UNHEATED SPACES TO BE w UP 18 R GUARDRAIL 3068 �,�a��. 2068 `" INSULATED IN ACCORDANCE WITH WSEC 2015. LD 0 N <n• EXTERIOR DOORS TO BE ADJUSTED SO 2 X 4 FURRING CTYP.) / WEATHER-STRIPPING, THRESHOLD, it DOOR SWEEP ARE I- D/G - .4 Sp s WORKING PROPERLY ; SEAL WELL. w W I" GAP (TYP.) - 5'-11 I/2" 2'-I1 I/2" Di ,01 s / /`^ • BLOWN-IN ATTIC INSULATION TO BE INSTALLED IN STRICT Lu .2 CONFORMANCE WITH MANUFACTURERS Q 0 F DENSITY COVERAGE. m RECOMMENDATIONS OR NS TY � .:...>:�.=.�k��a��ee������s��a���c��a�s�c��e�ec��o�ec����e��\��e����e���s��s�oUc��s�oUcs�s�oUe��s�����s�����s����s�s�s�e��e���������k�����e�.,:�.�,.�.:.�.,.:.�:.,.�:.:.,.�..::�.,:,.,,.,,.,:,.,,.,,.:�.�,.,,.,:�.,,.,,.,:.�:.:�.�:.:.,c..::�...:.�.,::.�.:�:�.�.. a E +aQ ° > ° �e , ° , o , , ° o PROVIDE VENT BAFFLES AS REQUIRED it INSULATE it = Z WEATHER-STRIP ATTIC ACCESS DOOR. U IJJ• PROVIDE MAKEUP AIR WITH FRESH AIR DUCTED >- Vw�y 26168 DIRECTLY INTO THE RETURN AIR PLENUM OF THE p FURNACE SYSTEM. INSULATE THE DUCT IN ACCORDANCE Q N TO WSEC 2015. PROVIDE DAMPER TO REGULATE UNDER STAR s INCOMING FRESH AIR. CC '^ ) STO'I I (UNEXCAVATED) • ALL GAS COMBUSTION APPLIANCES, EXCEPT STOVES 0 CLOTHES DRYERS, TO HAVE COMBUSTION AIR DUCTED I- IJJ ��o� DIRECTLY TO THEM. z w O w o e ° ' /�I� ' ' •• ALL COMBUSTION EXHAUSTS TO BE SEPARATED BY A MIN. 3' VERT. ; 10' HORIZ. O U) Z in o_ z N ~ Iz CRAWL SPACE ACCESS D 0 w O0 MIN. 24" WIDE X 36" TALL WHOLE-HOUSECDI o 2 (,) _ ACCESS DOOR z 09 z 3/4" PLYWOOD OR Q a VENTILATION OSB SUBFLOOR w N o ONE OF THE FOLLOWING METHODS WILL BE USED TO MEET z2 w 0 THE REQUIREMENTS OF THE INTERNATIONAL MECHANICAL . w •• # DOUBLE JOIST OR ` CODE (IMC)CHAPTER OF THE 2015 RC' U III 0 I- J BEAM PER PLAN W Q O w \\' Q U C.)(A). A SINGLE WHOLE-HOUSE EXHAUST FAN, WHICH CAN O z CC Q I N JOIST PER PLAN PERFORM DOUBLE DUTY AS A ROOM SPOT FAN, IS N Q m REQUIRED. FAN MUST BE CONTROLLED BY TIMER SET TO FIRE BLOCKING `' ` OPERATE MIN. OF 8 HOURS PER DAY. THE CFM CAPACITY OF FAN MUST BE 0.25 W.G. AND HAVE MAX. L SONE (NOISE)RATING OF 1.5. MIN. SIZE OF FAN MUST BE 105 CFM. PLYWOOD HANGERBOARD (B). FRESH AIR WILL BE CIRCULATED BY THE CENTRAL FASTENED TO CARRIAGES FORCED AIR FURNACE SYSTEM. FURNACE MUST HAVE 1 TO HEADER FRESH AIR INTAKE DUCT AND BLOWER MUST BE ACTIVATED SY TIMER TO CIRCULATE DAILY. (3)2 X 12 STRINGERS 5/8" TYPE "X" GYP. BOARD ON (GARAGE ABOVE) Z ALL SURFACES OF USABLE SPACE UNDER STAIRS INSULATION VALUES WALLS 11 ABOVE GRADE BELOW GRADE CI) STAIRS AT LANDING R-21 R-21 SCALE: 3/4" = 1'-0" CEILING FLAT VAULTED 0 R-49 R-38 O FLOOR CRAWL SPACE* SLAB ON GRADE SEE STAIR NOTES ON R-30 R-10 PAGE A4 FOR STAIR AND HANDRAIL NOTES i * R-30 INTENDED FOR USE WITH 9 1/2" CC I-JOISTS. IF 11 1/8" I-JOISTS USED THEN STAIR NOSING 3/4" - 11/4" PER IRC R311.1.5.3 OP OF HANDRAIL R 38 INSULATION TO BE INSTALLED. 0IJJ o O I 13-I"' I 32'-II'" 0 / 4 ill46-0 CD EXTEND TO TOP F / / m , BOTTOM RISER m RETURN TO WALL ',n - 5/8" TYPE "X" GYP. BOARD -) z co al DRAWN BY JAD ON ALL SURFACES OF USABLE Z QSCALE /4° O" UNO SPACE UNDER STAIRS N ., J II"** Q / F JD JOB# 1137NC17 DEMM DATE 11/21/2017 (3)2 X 12 STRINGERS J w ?C REVISIONS CONCRETE SLAB `�, F n LOWER FLOOR PLAN SEE ENGINEERING S2 FOR SHEAR WALL 12/31/2017 CEILING HEIGHT FIREBLOCKING AT TOP SPECIFICATIONS AND BOTTOM ACROSS ��STRINGER B/W STUDS 2X THRUST BLOCK — SCALE: 1/4"L = O' 844 S.F. LIVING SPACE -„ a a 8, STEPS, ADDED DECK fX a o a e 0 STAIRS AT FLOOR A5 SCALE: 3/4" = 1'-0" SHEET 5 OF 14 Paul Demmon 3518 W 2"d St Anacortes, WA 98221 360-739-8007 Pdemmon17c comcast.net Objective: Complete daylight basement @ 3518 W 2"d St,Anacortes Background: Permit# BLD-2017-0648 was issued for the vacant lot located @ 3518 W 2"d St and construction began on primary residence in Spring 2018.The approved design was a two-story residence with the downstairs being a daylight basement.The upstairs was completed and occupancy granted in May 2019.The daylight basement remained unfinished and the initial permit has expired. Scope: Complete the daylight basement as drawn per original plans,submitted under archived permit #BLD-2017-0648. The daylight basement, per design, is 1 bedroom, 3/4 bathroom, linen closet and a recreation room. Upon the initial build and relative to the daylight basement,this follows: • HVAC ducting was completed • CO/Smoke detectors are in service, connected to the whole-house system,and are on a dedicated electrical circuit • Rough sewer plumbing/venting is in place • Rough Hot/Cold water is in place • A separate electric subpanel is located in the daylight basement and was inspected by Labor and Industries • All applicable, necessary or associated inspections were conducted without condition or exclusion No structural modifications or additions will emerge due to the completion of the daylight basement.