Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File 220 East Park Drive
I r -Gs U ._, City of Anacortes Invoice/Permit#: BLD-2015-0010 904 6th Street Applied date: 01/12/2015 P.O.Box 547 Issue date: 01/12/2015 $ ' 1C?.'} Anacortes,WA 98221-0547 1891 4 Expire date: 01/07/2016 .:71 .a.ocS (360)293-1901 Job Address: 220 E PARK DR Permit Type: Demolition Permit ANACORTES WA 98221-1626 Project: APN: P57056 Remarks: Demolish portion of residence. maintain existing foundation Owner: SAMUEL TULL Contractor: RE-USE CONSULTING Address: PO BOX 508 Address: 2421 ST CLAIR ST ANACORTES WA 98221-0508 BELLINGHAM WA 98229 Phone: (360)399-7674 Phone: (360)201-6977 License#: General Information: Fees: Total Calculated: Adjustments: Deposits/Receipts: Total Due: THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REiULATI G CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. t - NA-1 etc C.4_ c.I2— SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY t l 01Alt" y ` ,,, ' CITY OF ANACORTES Jam . t : DEMOLITION PERMIT APPLICATION Site Address: 0 E /' J,-<v t' . n.i,,4 e"0 1..7` .S" 9 2.2- Assessors Account No.: P c 70 6-6 Date: f //2. f �}_c,r'f Lot(s): Block: Addition: l Owners Name: A., c ( t'_ 7 r..�,f Contractors Name: cam_( a C �1,,�;,.�r"i�,, Address: 0 O g,, .S o F. ,4-.,,,,,KrA1 Address: �.'� 2 ( WI: c-.✓.<- l%. 45---: _' /tay ,f 44,, State: (Al -- Zip: 7,Tau,. 1 State: (A/4 Zip: 5.. 0--2.z ' / `� Phone: 3 C 0 3 .7 9 7 f 2 y Contractors License: .D .c o.NS1-F73 3 y 7`e twig t. ce,,,74 c i 0 0,11, f cif 4 Phone: ,76 o 2 o / e j 7? Have Utilities Been Disconnected? Description of proposed demolition. Water Dept.: 0 No ,'1f ()A;Z`t p ,,,,t, / ()7 a 4't,57`4,.m Electric: Yes Cable: No S 7AL,e.1-cAk . f J -4a' c �4. M-7;1; J Gas: No How Will Materials be disposed?o / A ✓"'r'L►0��T ti ( L.,/i[ c' 4c cc c" ee,k( .-------—2 r f- / / ', BARRICADES TO BE PROVIDED FO' ' 4 ;LIC P: TECTION,AREA MUST BE ROPED OFF! / 1/17 c 4-1a c..Ve . A li' nt's o• ' gent's Si C...i ‘ so....1 ASBESTOS WARNING / 11W a`` ,,,As(9 Breathing asbestos is hazardous to your health. Before starting a renovation or demolition project, survey for friable asbestos materials. Notify Northwest Air Pollution Authority prior to asbestos removal or containment 1600 S. 21'd Street,Mt.Vernon,WA 98273 (360) 428-1617. I Fire Department Approval: ew?l'A X-r4rrGl 0/ Date: /2.....:7,j.3' Police Dept. Approval: Date: Public Works De artment A ? P pprov. ►. . %.... Date:\Za 1 q h4 Museum: d k 'o{ h7 5frv� .. , eaf11( Date: / 2"'''.7 - C kr- Comments: CAW v. t y0� fAt,O rttfa�1 d T e 'Print Window http://www.skagitcounty.net/Search/Property/?id=P57056 Details for Parcel:P57056 t Jurisdiction: ANACORTES Zoning Desig 4} Please contact the city of ANACORTES for ANACORTES jli+ zoning information_ Recorded Documents '' Documents scanned and recorded by the Parcel Number XreflD Quarter Section P57056 3780-000-011-0007 04 18 Owner Information Site Address(es) Location Map TULL SAMUEL C 220 E PARK DR Locate this Parcel on iMap HALL MURIEL K ANACORTES,WA 98221 PO BOX 508 Assessor's Parcel Map: PDF I DWF ANACORTES,WA 98221 2014 Values for 2015 Taxes* Sale Information 2015 Property Tax Summary Building Market Value $203,200.00 Deed Type WARRANTY DEED 2015 Taxes will be available after 2/15 Land Market Value +$233,800.00 Sale Date 2014-08-01 Total Market Value $437,000.00 Sale Price$480,000.00 Use the Taxes link above for 2014 tax Assessed Value $437,000.00 Taxable Value $437,000.00 *Effective date of value is January 1 of the assessment year(2014) Legal Description Definitions LOT 11,CAP SANTE PARK TO ANA.,RECORDED IN VOLUME 4 OF PLATS,PAGE 52,RECORDS OF SKAGIT COUNTY,WASHINGTON. Land Use (111)HOUSEHOLD,SFR, INSIDE CITY Neighborhood (21AVIEW)ANACORTES VIEW RESIDENTIAL Utilities WTR-P Levy Code 0900 Foundation HILLSIDE-MODERATE City District Anacortes Construction Style School District SD103 Exterior Walls SHAKE/SHINGLE Fire District Roof Style Year Built 1992 Roof Covering COMP Acres 0.20 Floor Construction WOOD SUB FLOOR Living Area 1804.00 sq ft Plumbing 2 FULL BATHS Bedrooms Heat-AirCond FORCED AIR Appliances BASIC APPLIANCE SET Fireplace DIRECT VENT Exemptions 1 of 1 17/19/7014 1.43 PM avower Coe 01,11/M F. Drawing Index Al SITE PLAN i-�I PROJECT INFORMATION AI FOUNDATION .__He Sex' I `;a� PLAN e'el'26`wBASSNOFF PLAN Ki Al FIRST FLOOR PLAN ��1- FLOORcoN ECM.FLOOR KAN A4 FIRST ?AWING PLAN HEC .FLOOR NO P PRANI PLAN D TalAs eu2ml 86CTpMS -- --- - - I `1 e ROOF 1RANIN6 LAN Doak - Al ENTROMP ELEVATIMB j _1I =� Project Information I ———I 0NBNML DNHCRIPTIM I I --,,,,,- NI r. project consists of a ea/ties-story mood Irene I I _� masj dams mitt basement awl attached garage. I 1 �� Q C00RS Oni20n Suild10g Cada-loss Washington State Eeaigy Cede-10S1 Iba Residence \ 1 NI a'City of Anscata toning,°canon. 16'0• t OCCUPANCY TYPE Type V,NM-rated I / \ Q m y 1.-hour fire saperetion(R-1/N) --' I Q N qg BUILDS.BEIWR TWO atoey OM-0.1 I , Y 8E.- BUILDING AREA Fleet Floor* 1,240 8P w t.Da" Swag•Floor. T52 SP s i-�---_ ` c Q Reef Om.,TO.� r----- at' Total Living Area* 1,848 SP a1.E -1-----i ry O• \ RC LEGAL DESCRIPTION Lot 11,of the Plat of Cl?Santa Park Addition to MumKas. SE 1/4,See 10-15-2 i / i _...iL,j // \\ o \\ Z Y / WW1 Pagoda Place i W CC CO i N 0 Site Plan p1 6 t° 1/TE ' 1 9133 a A 1 N Basement Plan N Foundation Plan °'^'. ^p d 10 ' `�ant 10 0 h lir Scale: Ile 1.-0' 01,31y52 Seale: 1l4' 1'-0' Ii'.p• ♦ d 1E p 1 ♦ g It 0 I 1 I (x� g } } i _. I t— -" :<,1l, Yam' I • } .__ , �_ ,,1 f-j �I —� } •` `X7 I ' I 1 I I (( o' i ; i _1 iZ °1i III ill° _ j ; j ! I I `— ' ---1 -- � I 13 ° (3 I — I bl , Garage d I { 11s m 1 e� It " I LI I U e Ill O Id 1-.— I { i Mech6rdcal I ! --� --� ® II 1NI , `QJ _ 1 1 1• N Crawl Spare m1 i -, o ' i 1.1 I W ro♦ I I U I z F INNOMMMI1111. 1--II --4 CO CD e'.e• o _e'd• j e'•o' I Z F ` 9 0 I 24 — Odyplal reinforced concrete sprat[sting.Sive °fYplal Yeln[oidM cantreta aLrbron grads S.Concrete tooting Schedule for additional !th mnstxue4on joints tc VIZ'.ersoking. requlreeente at rated lass. - ^^ ©Typical thickened,rraalGeereed...rats slab B6 O2 Typlc 1 reint[rced ^crate feundatlen vall.✓t—i-5-1 grads. See c Footing Schedule for v oaedation wall Male far «<i22///\ll%// on requiruante at a ed a1 additional reinforcilg req°ireesnta. leads. }/���=� Os'eeidal 1ed`pee* cml¢eta footing. 0�® Qprdwide biadkouts 1n caa[ete tawdetlai veil e Footing Schedule far additions or fiat sloe et dam..rapuirbaed. np. \/ A2 rrryinasents. exposed slab to drain aver from building. serov °Screened foundation v Provide 1 a°areH °Typical reinforad concrete Slab ograde for 044 ...of free areaeach 150 egaro VV drive., d sidewalk s with construction and feet of under-floor area. expnaion join.to control cracking. Slope to d Sr* r Peel/150 r 3.1 SFi drain away fres building. . 09497 .. _. S303.56 City of Anacortes Permit#: BLD-2012-0385 904 6th Street Issue date: 09/12/2012 „I P.O.Box 547 Expire date: 03/11/2014 Anacortes, WA 98221-0547 - ._ '+ "3_ (360) 293-1901 Job Address: 220 E PARK DR Permit Type: Single Family Alteration/Repair Permit ANACORTES WA 98221-1626 Project: APN: P57056 Remarks: Construct new porch. Owner: JOHN &SHEILA MAHER Contractor: Address: 220 E PARK DR Address: ANACORTES WA 98221-1626 Phone: Phone: License#: General Information: Fees: Building Valuation 10000 Building Permit Fee 181.25 Plan Review Fee 117.81 State Building Code Fee 4.50 Total Calculated: 303.56 Deposits/Receipts: 0.00 Total Due: 303.56 THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULA G CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. --/y/7 SIGNA OF OWNER OR AUTHORIZED AGENT ISSUE. BY (' virYll 1/1.2NIT2? j... ..1.30-24 '', -fr. ---. 1.4n1QA N i 6--4-1-0(77-1SCI .-...L.. 3) r\P--20.- ,.2 1 e\)i NV/ QJ. 1—ect4 `01NVV. Jv2 r 1 ) 1 01 -drl-a 6V C., „e=2- i I= ev \ _ ______ _ _________ \\•1 _r_ __, -• -Acre?wr,t,tr-13, • V ‘rov • 1/e,1 4.-0 ii 'I.?)50 L-9J. -4.1-_,\ () - c1-21d. vtvl •-.-5,--3_1= 7,-)vt,tv --aji\-- -1 --- -a-v ..1 -A 670-'' ', sto\t S' ......._ . .,41.1 ...„—........ 1 IZZ: I / • I. I 1 --0/7 v-i5V! Ai' I 7-artvi -L 517/S1 I ,1 . 1 I if i 1 F , , 1 , . 1 L _ ,...400.- . _ _„. ,r . , PERMIT FOWINSPECTIONS CALL: CITY OF ANACORTES. r .„. . . 2P1901 BUILDING PERMIT , . . .i, 24 Hrs. Notice Requested SbAddnem(20 East Park Drive) - •--= . NAKIE(OSNASSSOSUSINESS) . - PLIthillNG Paul St Connie Evans ' lti NAILDIG ADDRESS . . ., "t1 12-6q triti.0.1144. riZoeve/ No. TYPE OF FIXTURE Olk ITEM Fri 9, , CITY TELEPHONE NUMBER , 2 water Closet ' $ 4.00 , Anacortes, WA 9822' 293-6097 2 Bathtub . 4.00 NAME , 3 Lavatory 6_,00 Ron Smith . i Shower ' a,00 (1/4( tj- E ADDRESS . I_Kitchen Sink • 2 00 ,.- 1008 5th Street 1 Dishwasher 21,00 CITY TELEPHONE NUMBER I Laundry Tray 2t.00 Anacortes, WA 98221 293-2585 Clothes Washer ,:•., ';• NAME 1 Water Heater 2 .00 kr: Kiser Construction . , Urinal ADDRESS Drinking Fountain Cr" 2301 lith Street . Floor Sink or Drain . f r^ CITY TELEPHONE NUMBER Slop Sink 8 Anacortes, WA 98221 293-2507 - 1 Water Piping 2..00 STATE LICENSE NUMBER CITY LICENSE NUMBER r i . , . ,1 '.1 OltaiderWal 0 Non-Residential 'r, . PERMIT $ a,no ',./' figew 0 Add 0 Alter 0 Repair TOTA4fEE $ 29.00 , 011uilding 04Plumbing Oftilechanical MECHANM4L , 0 Sign 0 Demolition b Other 04GAS 0 OIL El ELECT 0 OTHER ' Legal Description of Property or tut Account Number No. TYPE OF EQUIPMENT FEE Lot I 1 Block of ep Sante Park Addition Addition $'.E. 1/4 Air Cond. Unit , $ Section 18. 35.2 Refrigeratiod Unit- ., HP . ' Boiler- ' HP I Forced Air SSrswin : BTU/ICW 9.00 Describe Work . Floor Furnace ' New residence Wall Heater - , Unit Heater Clothes Dryer Occupancy Use 4,Ventilation Fan 28,00 . , OSSingle Family Residence 0 Multi-Family Residence Range Hood • 0 Office 0 Retail 0 Storage 0 Church Air thindling Unit- ,, CFM • F .tt 0 Restaurant 0 Other _ , Pre-manufactured Stove or Firephice -. NOTICE 1 Gas Piping 3.,00 This permit is issued by the Building Official and,under the provisions 'i'•, of the Uniform Building Code;shall eitpize,by lintitatitheand become null ' and void if the building or work authorized by such permit is not corn- PERMIT $ 15 00 . ' mewed within 180 days from the date of pennit issuancs4 or if the building TOTAii TEE $ 53 00 or work authorized by such permit is suspended or abauti. oned at any time , , „.,• - after the work is commenced for a period of 180 daisi. TOTAL FEES VALUNFION FEE By affixing my signature, I hereby certify that I turYthe owner of the B 'Id* 2 108.000.00 $ 453 00 .,. property for which this permit is issued or am an atithorizta represen- ' '- Plan Check 244 00 tative of the owner. DI Plumbing 29 00 -t All provisions of laws and ordinances governing this type of work will h4echanical 53 00 be complied with whether specified herein or not,including routine calls .:. foryons Sign ' Demolition ,"" ...ie Energy Surcharge "moue doØr or Authorized Aga* re' State Surcharge 4 50 Other Sewer 2839 OG ' : Street Setback 20 t Side Yard Sobert 10 r Rear'riot setha 20, TOTAL $ 3.622.50 - __. Conditions: I.Use Zone RL "1'4'7 Gm'?R3/M TY"cirwisi. VN .: Lot Ares she Ethelling unit 7545 = 0 No 1 0 Pile Sprinkle", Required N2 of Stories Bars Occupui Load Yes o No .Size of Bldg than.nitwits By! -Cy-re-Cbrnish , Immvs . , s . imeemmeememasemeimmaimmr „ Porde=is itteSto Oa to ei the abovaiireitia ink accontleibithe mations horn and ajbwithito Om appre4ii, pies aoitesitatiticso partidreng that°,subject to 1 toosplinto with the calm=of the CITY Or ANACORTES. ,,, 02/21/92 Permit Issued BY rY) i( 110.1,‘0 ( ''''''r OE 11, \\ .... Building Official Edwin Frank [ slim - ... . PERMIT Ne 9529 4201 3pAiiits-and SMITH JOB U n[l1 61 b��llG ARCHITECTS, AIA SHEET NO. f OF 2 1008 Fifth Street ANACORTES, WASHINGTON 98221 CALCULATED BY ; ', V/1I DATE 2 2� _ '- • (206) 293-2585 CHECKED BY DATE __ IIi SCALE �1l�1ioYl E}US2(p �JISf �?Cbi�1 YYa l) 3���C' i 1 . , ... .._... , . _._______ _.,_ .. .....„. , . . . . if . i . __..... . Is • • ail , : _-46 CD �YIG{r . ... .. . . . . . .. rel 4111611 „ ci • aasR i A, i • iictat,!.�• �� .. - STATE I:r1 i _ i d) : Eii II . .. (' --1?-) '01_ ). . '3 FORM 2O4-, Available from/A sflrc.Groton.Mass.0145O la =1III . . . 8" CO _IIIl= 9 CONCRETE =llil .• • FOUNDATION IIII t 6 WALL WI=•• • 2-#4 IIII=.li1 a • HORIZONTAL Min- •'0 • 0 REBAR =1111 • • • AT 12 O.C. IIII= - • CONTINUOUS II_II • . �a CLEAR WI . d • I.1/2" CLEAR _ ���� o• ° , #4 =1111n . 0 . • VERTICAL 1111E1111 • REBAR III— • 0 II AT I2" OC. IIIi • • • EACH FACE (2t1 CONCRETE WALL 3 1•1/2" = I' - 0" N CO y ill • 0 • ' REBA4 R VERTICAL a = • t ° ATI2"' 0.C. • a o� •• EACH FACE 0 , 2- #4 () • HORIZONTAL rt°i —III '. REBAR CONT. 'iT • • • o• • �L —•:��. -co • 600 •. Q° • •. -h LAI UNDISTURBED - 18" FIRM EARTH i (22�1 CONCRETE FOOTING 3___/ I•V2" = I' - 0" PROJECT: 9133 EVANS RESIDENCE ANACORTES, WASHINGTON 1991 WASHINGTON STATE ENERGY CODE COMPONENT PERFORMANCE (TRADEOFF) COMPLIANCE APPROACH (TABLE 5-1) Gas Forced Air Climate Zone 1 Cathedral and Flat Ceilings Heated Floor Area = 1,978 SF (New Construction) Glazing Area Factor (G1) = 1,978 x 15% = 297 SF * A. B. C. D. E. F. G. H. COMPONENT GROSS NET REQ'D DESIGN REQ'D DESIGN SUMMARY AREA AREA U-VALUE U-VALUE U x A U x A (F-G) W9 Wall 2516 2057 0. 062 0. 0559 127 . 534 114 . 9863 12 .5477 W29 Wall 232 232 0.062 0.0572 14 . 384 13 . 2704 1. 1136 W7 Wall 248 210 0.062 0. 056 13 . 02 11.76 1.26 Wall 0 0 0.062 0 D 0 0 Wall 0 0 0.062 0 0 0 0 * Windows 297 297 0. 65 0 193 . 05 0 193 . 05 G1 Windows 366 366 0 0. 38 0 139 . 08 -139. 08 G2 Windows 6 6 0 0. 39 0 2 . 34 -2 . 34 Windows 0 0 0 0 0 0 0 D1 Doors 61 61 0.4 0. 33 24 .4 20. 13 4 . 27 D2 Doors 60 60 0.4 0. 31 24 18 . 6 5.4 1 Doors 0 0 0 0 0 0 0 Doors 0 0 0 0 0 0 0 C2 Ceilings 896 890 0. 034 0. 0257 30.26 22 . 873 7. 387 C2 Ceilings 346 346 0. 036 0. 0257 12 .456 8 .8922 3 .5638 Ceilings 0 0 0 0 0 0 0 F1 Floors 1114 1114 0. 041 0. 0507 45. 674 56.4798 -10.8058 Floors 0 0 0. 041 0 0 0 0 Floors 0 0 0 0 0 0 0 Floors 128 128 R-10 R-10 -- -- -- 484 .778 408 . 4117 76. 3663 NOTE: The total of Column H must be greater than or equal to zero for compliance. BTU/HR/ COMPONENT VOLUME AC/HR DEGREE U x A INFILTRATION 19022 0.4 0. 018 136.9584 SUMMARY U x A (BTU/HR/DEGREE) 545. 3701 ti • a) � 11t10 o *.elftli o Ali . rf 4 ' kag I 0 IL I we INSULATED WALL Wir 3" = II - 0 " L • INSULATED WALL (W. 07) R-VALUES FOR BETWEEN AT BUILDING MATERIALS FRAMING FRAMING A. Inside air film 0. 68 0 . 68 B. . 5" Gypsum wallboard 0 . 45 0. 45 C. Polyethylene vapor barrier 0 . 00 0 . 00 D. 5 . 5" Wood stud framing @ 16" o.c. 0 . 00 6 . 88 E. R-19 Fiberglass batt insulation 19 . 00 0 . 00 F . . 625" Gypsum wallboard 0. 56 0 . 56 G. Outside air film 0 . 68 0 . 68 TOTAL R-VALUES (R) 21. 37 9 . 25 INSULATED FRACTION (IF) 0 . 85 0 . 15 U-VALUES (IF/R) 0. 0398 0 . 0162 U-VALUE (AVERAGE) 0 . 0560 L. Q ` , O� �III om ftp AM' Oo�� hi ! ° ill II; NI 0 �N INSULATED WALL 11 3" - I' - Olt INSULATED WALL (W. 09) R-VALUES FOR BETWEEN AT BUILDING MATERIALS FRAMING FRAMING A. Inside air film 0 . 68 0 . 68 B. . 5" Gypsum wallboard 0 . 45 0 . 45 C. Polyethylene vapor barrier 0 . 00 0 . 00 D. 5 . 5" Wood stud framing @ 16" o.c. 0. 00 6 . 88 E. R-19 Fiberglass batt insulation 19 . 00 0 . 00 F. . 5" Plywood sheathing 0. 63 0. 63 G. Air infiltration barrier 0 . 00 0 . 00 H. . 375" Plywood siding 0 . 47 0 . 47 I . Outside air film 0 . 17 0 . 17 TOTAL R-VALUES (R) 21 . 39 9 . 27 INSULATED FRACTION (IF) 0 . 85 0 . 15 U-VALUES ( IF/R) 0 . 0397 0 . 0162 U-VALUE (AVERAGE) 0 . 0559 • • • •0 OQ D • • 0ti0 00 0 � . o 0 o • co 0 • 0 • 00 0 CO• D O © INSULATED WALL 29 3" = I ' - 0 " 9 INSULATED WALL (W. 29) BUILDING MATERIALS R-VALUES A. Inside air film 0 . 68 B. 2" Foil-faced polyisocyanurate 16 . 00 C. Adhesive 0 . 00 D. 8" Concrete 0. 64 C. Outside air film 0. 17 TOTAL R-VALUES (R) 17 . 49 INSULATED FRACTION (IF) 1 . 00 U-VALUES (IF/R) 0. 0572 U-VALUE (AVERAGE) 0 . 0572 5 . • Milgard 5 0.0 0 SERIES VINYL WINDOWS AAMA 1503.1 - 88 TEST RESULTS • "U" VALUES (TEST PPS) PRODUCT GLAZING OPTIONS CLR/CLR CLR/CLIL ma/"Eft CLR/"E" argon argon 5120 .44 37 .38 .34 H-SLIDER (89-58) (90-124) . (89=103) (89-104) 5220 .47 .40 .40 .34 -HUNG (89-88) (90-204) (89-86) (89-87) 5320/5720 .49 .43 .35 .33 PIC/RAD (89-149) (90-312) (89-158) (89-167) 5420/5520 .38 .35 .34 - .31 CASE/AWN (89-163) (89-164) (89-165). (89-166) 5620 .51 .48 .42: .39 S-DOOR (89-265) (89-266) (89-267) : •(89-268) • L� GLAZING/ WI \ DOW TYPE COMPLETE GLAZING TEST REPORTS LIST 28 January 1986 Seattle Department of Construction and Land Use Product Description U-Value Product - Glass Type Product Type Test Test Value Adjus . Manufac- and Coating Air- Sash and @ 15 + = U- turer (if not clear) space_ Type Model Number , MPH Adjustment Value Northwest double, clear alum, single hung/825 yes .66 + - - .66 Aluminum sliding door/720 yes .70 + - = .70 sliding win./525 . yes .67 + - _ .67 alum. w/tb fixed/3128 yes .56 + - = .56 single hung/8130 yes .56 + - = .56 sliding door/7130 yes .55 + - _ .55 sliding win./5130 yes .55 + - = .55 skylight/9130 yes .64 + - _ .64 double w/low-E alum, single hung/825 yes .55 + - _ .55 (Sungate 200) sliding door/720 yes .58 + - = .58 sliding win./525 yes .56 + - = .56 alum. w/tb single hung/8130 yes .40 + - = .40 sliding win./5130 yes .40 + - = .40 triple, clear alum. w/tb fixed/3128 yes .40 + - = .40 single hung/8130 yes .45 + - = .45 sliding door/7130 yes .44 + - _ .44 sliding win./5130 yes .45 + - _ .45 1 1 Pinecraft double, clear wood casement/80 no .429 + .08 = .51 Windows double hung no .503 + .08 = .58 triple, clear _ wood casement/80 no .392 + .08 = .47 ' Pozzi double, clear wood casement/2NN44 yes .50 + - = .50 Windows casement/2NN44 no .43 + .07 = .50 double + storm wood casement/2NN44 yes .39 + - = .39 casement/2NN44 no .31 + .08 = .39 United double, clear alum. w/tb - /600T yes .66 + - = .66 Glass Velux double w/low-E clad wood skylight/FSVHH .39 + }> .39 America (Veltermplus) Viking double + storm alum. w/tb sliding win./900 yes .37 + - - .37 triple, clear alum. w/tb fixed/1900 yes .41 + - = .41 Wells double, clear- alum. w/tb sliding door/M1100 yes .67 + - = .67 Aluminum © GLAZING/ WINDOW TYPE v . II ! . i • • j j 0 0 I I . i I h i I SOLID CORE DOOR 63") 3" = (' - 0" • Building Materials R-Values A. Inside air film 0. 68 " B. 1-3/4" Solid core flush wood door 2 . 19 C. Outside air. film 0 . 17 Total R-Values 3 .04 Insulated fraction (IF) 1. 00 U-Values (IF/R) 0 . 3300 U-Value (average) 0.3300 PERFORMANCE DATA TS/TECHNICAL SUPPORT • • 1991 Values Based on 'k Relative Product Lawrence 9erkrieyLabs.Window 3.1 Humidity When ANDERSEN,'RESIDENTIAL Centtrr°I Moisture Forms Inside Glass (;lass Unit"U" Unit"R" at Center Surface Shading Rdaure WINDOWS AND PATIO DOORS "U"Value Value Value of Glass Temperature" Coefficients' HeatG.uin" HIGH-PERFORMANCE INSULATING GLASS' . H.P 11.1l H.P. Sun H.P. sun I'emu•ShieldCasement .26 .30.34 3.3.2.9 62% 56° .74 .37 152 7.z, IermaShieldAwning .26 .30„S4 3.3.2.9 63% 57° .74 .37 15% is 1'umu-ShieWlasement;Awning Picture Windows .27 .29-.32 ;3.4.3.1 61% 56° .73 .35 Us :I Nana-ShieldNarroline .26 .241-.33 3.5.3.0 63% 57° .74 .37 152 7n HWmta•Shkld Narmline Picture Windows .27 .29-.31 3.4-3.2 62r% 56° .73 .35 11S 71 Frenchwnod Hinged Patio Doors= .26 .28-.31 Q�i�s.2 62% 56' .71 .35 14n 71 Frenchwu d Gliding Patio Doors' .26 .28-.31 3.6-3.2 62% 56' .72 .35 14.v ` 7 t I'emu•Shield Gliding Patio Doors= .27 _ .28-.31 3.6.3.2 61% 56' .72 .35 147 :t I'emu-Shield Circle Top Windows" .26 .311-.35 3.3-2.9 62% 56' .74 .37 151 77 Elliptical .26 .32-.34 :1.1.2.9 62% • 56' .73 35 1511 - I Arch Window - ,26 .34 2.9 63% Si= .73 .36 I:+' Ti, Circle Oval .26 .31-.34 3.2-2.9 62'k 56` .74 .37 Li 7. Irmo-Shield Fkxiframe .26 .31 3,2 63% 57: .77 35 14.4 1 7.l- Roof Window tenting rat 45°angle-12/fzpitch) .32 .36-.40 2.8.2.5 59% 55' .73 .36 Iy' 75 Rvd Window Stationary tat 45°angle-12112 pitchP .32 .36-.40 2.8-2.5 59% -53' .73 .35 1.511 7, DOUBLE PANE INSULATING GLASS • Perma-Shied Gliding Windows .55 .48 2.1 37% 43- .91 l.. psi • TRIPLE-GLAZED lemu-Shield Casement with High Performance Double Pane and RGP -2o .25 4.0 70% 6tf- Ti,. .41 _ 144 ;•.-. Derma-Shield Awning with High Performance . Double Pane and RGP .20 .24 4.2 70% tdi° .70 .41 144 Perna-Shield Narroline with High Performance Double Pane and Combination Unit .20 .24 4.2 70% 61.1: .70 .41 111 . Perna-Shield Gliding with I kmbk Pane and Combination Unit .35 .36 2.8 53% 52: ' .83 171 SINGLE-GLAZED Singly Si;mcParr Pane Dal - _'!N - Basement Windows' 1.11 .g4 1.2 13% 17` Basement Window Single Pane with RGP .49 .43 'z.i 41% 45' .90 - l$, Footnotes: Information of Data Sources. 'Except as noted all figures pertaining to High-Performance insulating glass •The unit figures in this table have been determined utilizing current.ASI IR\E also apply to High•Performance Sun insulating glass methods and are consistent with the current issue of the ASIf RAE lfandbook lit -72"x80-door size used.The Window 3.1 Program has no provision for patio doors. Fundamentals(19891. All patio door glazing is tempered. •All calculations are based on Lawrence Heckele'-Laboratories Windom 3.1 'Based on equivalent square footage;sizeapproximated. computer program and ASHRAE recommended window sizes.The Ll3L pro. 'All roof window glazing is tetupered. gram accounts for edge effect of insulating glass and frame material, it the `Based on largest size Andersen Basement Window window unit. "Inside glass surface temperatures for determining%relative humidity are taken •The center of glass"U"values are supplied by the glass manufacturer. from center of glass. •Calculations assume the following: The shading coefficients listed may vary(+or-)a few percentage points Outside Temperature:U Degrees E Fur shading coefficients on specific size units contact Andersen Corporation. Inside Room Temperature:70 Degrees E 'Relative Heat Gain BTIESq.Ft./Hr.;When ASHRAE solar heat gain factor Outside Wind Velocity:15 MPIl is 2W BTU.Hr.Sq.Ft.and outdoor air temperature is 14°wanner than the No Air Movement Inside;and Uniform I(eatng Conditions. indoor temperature. Abbreviations N;A:Not Applicable RGP:Removable Glazing Panel • �2./ N U d- v O • e L2. © a INSULATED CEILING CU R-Values for Between At Building Materials Framing Framing A. Attic air film 0 . 61 0. 61 B. R-38 Fiberglass batt insulation 38 . 00 26 . 92 C. 3-1/2" Wood roof trusses @ 24" o.c. 0 . 00 4 . 38 D. Polyethylene vapor barrier 0. 00 0 . 00 E. 5/8" Gypsum wallboard 0 . 56 0 . 56 F. Inside air film 0. 61 0. 61 Total R-Values 39.78 33.08 Insulated fraction (IF) 0. 88 0. 12 U-Values (IF/R) 0 . 0221 0. 0036 U-Value (average) 0. 0257 • • ill 1 e revo 0 • a INSULATED FLOOR IEF 3" = _ 0" 1 R-Values for " Between At Building Materials Framing Framing A. Inside air film 0 . 92 0 . 92 B. Carpet with rubber pad 1 . 23 1 . 23 C. 3/4" Plywood subfloor 0 . 94 0 . 94 D. Polyethylene vapor barrier 0 . 00 0 . 00 . E. 5-1/2" Wood floor joists @ 16" o.c. 0 . 00 6 . 88 F. R-19 Fiberglass batt insulation 19 . 00 0 . 00 G. Crawl space air film 0 . 92 0 . 92 Total R-Values 23.01 10.89 Insulated fraction (IF) 0 . 85 0 . 15 U-Values (IF/R) 0 . 0369 0 . 0138 U-Value (average) 0.0507 1�1s ,�, -_ 2 -r� B 81 Zz of c 61 Ile c v Y o CITY OF ANACORTES • WASHINGTON • De oR BUILDING DEPARTMENT CERTIFICATE OF OCCUPANCY This is to certify that the(Description of Building or Structure): Single Family Residence Located At: 220 East Park Drive STREET&NUMBER Owner: Paid & Connie Evans Constructed By: Kider Construction OWNER OR CONTRACTOR Bldg.Permit# 9329 Date Of Issue: 2_.2i 9 0cc.Group: Use Zone: `�L • Has Been Inspected And Occupancy Is Hereby Authorized, • This 18th Day Oj September 19 ' I THORI N OFFICIAL SEE REVERSFr/'SIDE FOR SPECIAL REQUIREMENTS. I : 9529 220 East Park Drive 2-21-92 Paul & Connie Evans Kiser Construction VN R3 RL Single Family Residence s-i_€i-9 - %c\11-keE-.o F W-T--re- Egg— k 3 -.25-92_ET_G- z3,..,4) -,9167-7 co y_ s/«-7 - r ,14-o i - 0,6 Q-t , o(c- c(r Qt !. USteL1 akJ LCU•gey iilso_a_ _ Ir .S-.-2es-ft ` it cot b-z- 9z fbs — 0K ei- I -52- sE-az ok ----Ik-9-z, Fi_NB\ SEE C `sr