Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File BLD-2020-0425 3513 W2nd Street
_. sY 0 Cityof Anacortes Invoice/Permit #: BLD-2020-0425 904 6th Street Applied date: 07/21/2020 P.O.Box 547 Issue date: 07/23/2020 Anacortes, WA 98221-0547 Expire date: 01/19/2022 Ix._,fir 0 lk ' -_� (360) 293-1901 Job Address: 3513 W 2ND ST Permit Type: Single Family Alteration/Repair Permit ANACORTES WA 98221-1267 Project: APN: P105832 Remarks: INSTALL PV SOLAR PANELS ON ROOF MOUNT. *** CONTRACTOR WILL NEED A CITY OF ANACORTES BUSINESS LICENSE ENDORSEMENT PRIOR TO STARTING WORK*** Owner: WILLIAM & VICTORIA BENHAM Contractor: SOLGEN POWER LLC Address: 3513 W 2ND ST Address: 1992 SAINT ST ANACORTES WA 98221-1267 RICHLAND WA 99354-5314 Phone: (707) 227-6747 Phone: (509) 530-2369 License #: General information: Fees: Building Valuation 2580 Building Permit Fee 83.25 Plan Review Fee 54.11 State Building Code Fee Resi 6.50 Total Calculated: 143.86 Deposits/Receipts: 0.00 Total Due: 143.86 The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of tr is permit is interpreted to allow construction activity during any period of time when c11r-h construction is prohibited or restricted by any state or f&J 'di !a%,.. or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor. This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and exa ' application and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY G o� PLANNING,COMMUNITY,& ECONOMIC DEVELOPMENT DER I V fr y Mailing Address:P.O. Box 547,Anacortes, WA 98221 l Office Location:904 6th Street,Anacortes WA 98821 it I 21 2020 ti w Phone:(360) 3-1901 Lap O 2,0 — 0 LI aF FORM BP-1: RESIDENTIAL BUILDING PERMIT APPLICATION 1. PROPERTY INFORMATION Project Address(Street,Suite#): Assessor Parcel Number: 3513 W 2nd St. Anacortes, WA 98221 Subdivision/Lot#: Zoning Designation: Lot area(size): 7,405 sq.ft. 2. TYPE OF PROJECT ❑ New SFR ❑ New Accessory Dwelling Unit: ❑ Deck/porch(new/repair) 0 New Duplex ❑ Attached to Primary Unit 0 Interior remodel ❑ Detached from Primary Unit ❑ New Addition to SFR ❑ Garage,carport or accessory building 0 Fence or retaining wall or duplex (new/repair) In Other: Project Summary: PV Solar Panels roof mount Project Valuation: $ 2,580 3. PROPERTY OWNER INFORMATION Name: William Benham Phone: (707)815-8222 Address(Street,City,State,Zip): Email Address: 3513 W 2nd St. Anacortes, WA 98221 vb53@comcast.net 4. CONTRACTOR INFORMATION Name:* Solgen Power, LLC Phone: (509)530-2369 Contractor's Business Licenses State License#: City License#: *All Contractors&Subcontractors must have a valid City SO LG E P L830 RJ of Anacortes business license prior to doing work in the Expiration Date: Expiration Date: City. 01/24/2022 Address(Street,City,State,Zip): Email Address: ermlttln sol en ower.com 1992 Sain St Richland Wa 99354 p g@ 9 p 5. CONTACT PERSON Select one person the city will contact for anything r=uu Applicant ID Property Owner El Contractor related to this project: ❑ Other(list below) Name: Lorena Pulido Phone: (509)530-2369 Address(Street,City,State,Zip): Email Address: 1992 Saint St Richland Wa 99354 permitting@solgenpower.com Res.Building Permit Application Submittal Checklist Updated October 10,2019 Page 5 of 18 C)‘" o PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT Mailing Address:P.O. Box 547,Anacortes, WA 98221 Office Location: 904 6th Street,Anacortes WA 98821 tiq w� Phone:• (360)293-1901 6. LENDER INFORMATION RCW 19.27.095 requires the City to obtain information with regard to lenders. If there are no lenders involved with your project, write"no lenders"on the Name Line below. Name: No lenders Phone: Address(Street,City,State,Zip): Email Address: 7. ACKNOWLEDGEMENTS & SIGNATURE Read and initial each of the following statements prior to signing this application: I understand that when a building permit application is taken in over the counter it does not mean LP the application has been deemed technically complete and sufficient for staff review. I understand that if I submit incomplete, inaccurate, and/or erroneous information it will take the LP City longer to process my permits. LP I understand and acknowledge that I could be responsible for providing as-built drawings(on paper or electronically)as part of the project's certificate of occupancy process. LP I understand and acknowledge that Special Inspections could be required as part of my project,and if needed I will be required to pay for the cost of these inspections. I understand and acknowledge that financial securities could be required as part of the work I am LP completing and I agree to provide the items needed for the City to calculate these securities and to provide the securities themselves. LP I understand that if permits are reviewed concurrently such as design review,site plan,traffic concurrency,etc.,any required revisions to one permit may affect the entire plan set and could add costs and time to the project. I hereby declare that I am either the owner of the property listed on this application or the owner of this property has authorized me to be their representative to act for them. I also declare under penalty of perjury under the laws of the State of Washington that all of the statements and answers contained herein,and the information submitted with this application form is in all respects,true, correct, and complete to the best of knowledge and belief. 07/13/2020 Sign ure frjsjt-I'LL-j-4) Date Lorena Pulido Printed Name Res.Building Permit Application Submittal Checklist Updated October 10,2019 Page 6 of 18 To Be Completed By the Applicant Project Address: 3513 W 2nd St Anacortes, WA 98221 Project Applicant: Lorena Pulido Applicant Email: permitting@solgenpower.com Phone No.: (509)530-2369 Site Owner Name: William Benham PV System Description: PV solar Panels roof mnunt Determine if your project is eligible for an over-the-counter Permit(Check Yes or No) Yes No 1. PV System is designed and proposed for a detached single-family house,duplex or j ❑ townhome. 2. PV System is designed for rooftop of house in general compliance with applicable xi D codes. 3. Mounting system is engineered and designed for PV. tiC ❑ 4. Rooftop is made from light weight material such as shingles. II ❑ 5. PV system will be permitted and pre-approved by Labor&Industries Electrical kl ❑ division. 6. To address uplift,panel are mounted no higher than 18"above the surface of the xi ❑ roofing to which they are affixed. Except for flat roofs,no portion of the system may exceed the highest point of the roof. 7. Total deal load of panels,supports, mountings,race ways,and all other ❑ ❑ appurtenances weight no more than one of the following. IF Yes,indicate which: x No more than three and one half(3.5 pounds per square foot(PSF) n Frameless panels on at least 3/12 pitch roof weighing no more than four and one-half(4.5) PSF ❑ Frameless panels on at least 5/12 pitch roof weighing no more than five(5.0) PSF 8. Supports for solar panels are installed to spread the dead load across as many ® ❑ roof-framing members as needed to ensure that no point loads in excess of fifty (50)pounds are created. 9. Attachment to the roof is specified by the mounting system manufacturer. Q ❑ 10. Panels are mounted no higher than the roof ridge or apex of roof(applies only to Pg ❑ pitched roofs). Comments: At By Checking this box,I certify that all of the information provided on this form is correct. If you answered yes to all of the above questions,your PV installation is eligible for an over-the-counter building permit. To apply please bring in this completed form to our permit center at City Hall for an over-the-counter permit. To be Completed By Staff Project is eligible for over-the-counter permit? ❑Yes ❑ No t \\ ., ECTOR Eli GIFIEER s VSE Project Number: U2782.1000.201 July 10, 2020 Solgen Power ATTENTION: Collin Prisbrey 5100 Elm Rd Pasco Pasco, WA 99301 REFERENCE: William Benham Residence: 3513 West 2nd Street, Anacortes, WA 98221 Solar Array Installation To Whom It May Concern: Per your request, we have reviewed the existing structure at the above referenced site. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on the panel layout plan. Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. Design Parameters Code: 2015 Washington Building Code (2015 IBC) Risk Category: II Design wind speed: 110 mph (3-sec gust) per ASCE 7-10 Wind exposure category: C Ground snow load: 15 psf Seismic design category: D Existing Roof Structure Roof structure: 2x4 manufactured trusses @ 24" O.C. Roofing material: composite shingles Roof slope: 33° Connection to Roof Mounting connection: (1) 5/16" lag screw w/ min. 2.5" embedment into framing at max. 48" o.c. along rails (2) rails per row of panels, evenly spaced; panel length perpendicular to the rails not to exceed 67 in Conclusions Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Therefore, the requirements of Section 807.4 of the 2015 IEBC are met and the structure is permitted to remain unaltered. 651 W. Galena Park Blvd., Ste. 101 / Draper, UT 84020 / T (801) 990-1775 / F (801) 990-1776 / www.vectorse.com i VSE Project Number:U2782.1000.201 William Benham Residence ECTOR 7,10,2020 E r'i G I I"l E E R S III The solar array will be flush-mounted (no more than 6" above the roof surface) and parallel to the roof surface. Thus, we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind(uplift), the governing load case. Regarding seismic loads, we conclude that any additional forces will be small. Conservatively neglecting the weight of existing wall materials,the installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 2.1%. Because the increase in lateral forces is less than 10%, this addition meets the requirements of the exception in Section 807.5 of the 2015 IEBC.Thus the existing lateral force resisting system is permitted to remain unaltered. Limitations Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. The contractor must notify Vector Structural Engineering,LLC should any damage,deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found. Connections to existing roof framing must be staggered, except at array ends, so as not to overload any existing structural member. The use of solar panel support span tables provided by others is allowed only where the building type,site conditions, site-specific design parameters,and solar panel configuration match the description of the span tables.The design of the solar panel racking(mounts,rails, etc.)and electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Vector Structural Engineering assumes no responsibility for improper installation of the solar array. VECTOR STRUCTURAL ENGINEERING,LLC WA Firm License: 2202 LIND !{p4 44 4 WASy, . 4 1, �j� Q &_,, ,4 f .6 C'i5 I 00. ,. 44. .4'4ss/UNAL u, 07/10/2020 Wells Holmes,S.E. WA License: 51006-Expires: 10/06/2020 Project Engineer Enclosures WLH/ajf 651 W. Galena Park Blvd.,Ste. 101/Draper, UT 84020/T(801)990-1775/ F(801)990-1776/www.vectorse.com JOB NO.: U2782.1000.201 VECTOR SUBJECT: WIND PRESSURE E n G I n E E R S PROJECT: William Benham Residence Components and Cladding Wind Calculations Label: Solar Panel Array Note: Calculations per ASCE 7-10 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]: 110 Notes: Exposure Category: C Risk Category: II ADDITIONAL INPUT & CALCULATIONS: Height of Roof, h [ft]: 25 (Approximate) Comp/Cladding Location: Gable Roofs 27°<A<_45° Enclosure Classification: Enclosed Buildings Zone 1 GCP: 1.0 Figure 30.4-2C (enter negative pressure coefficients) Zone 2 GCP: 1.2 Zone 3 GCP: 1.2 a: 9.5 Table 26.9-1 zg [ft]: 900 Table 26.9-1 Kh: 0.95 Table 30.3-1 KZt: 1 Equation 26.8-1 Kd: 0.85 Table 26.6-1 Velocity Pressure, qh [psf]: 24.9 Equation 30.3-1 GCP;: 0 Table 26.11-1 PRESSURES: p=q,,[(GCp)—(GCp1)j Equation 30.9-1 Zone 1, p [psf]: 24.9 psf (1.0 W, Interior Zones, beyond 'a'from roof edge) Zone 2, p [psf]: 29.9 psf(1.0 W, End Zones, within 'a' from roof edge) Zone 3, p [psf]: 29.9 psf(1.0 W, Corner Zones, within 'a' from roof corner) (a= 3 ft) JOB NO.: U2782.1000.201 / Ec-rcF E rl G I n E E R S SUBJECT: CONNECTION PROJECT: William Benham Residence Calculate Uplift Forces on Connection Pressure Max Connection Max Trib. Max Uplift (0.6 Wind) Spacing Area2 Force (psf) (ft) (ft2) (Ibs) Zone 1 14.9 4.0 11.2 167 Zone 2 17.9 4.0 11.2 200 Zone 3 17.9 4.0 11.2 200 Calculate Connection Capacity Lag Screw Size [in]: 5/16 Cd: 1.6 NDS Table 2.3.2 Embedment3 [in]: 2.5 Grade: SPF (G = 0.42) Nominal Capacity [Ibs/in]: 205 NDS Table 12.2A Number of Screws: 1 Prying Coefficient: 1.4 Total Capacity [Ibs]: 586 Determine Result Maximum Demand [Ibs]: 200 Lag Screw Capacity [Ibs]: 586 Result: Capacity> Demand, Connection is adequate. Notes 1. 'Max Connection Spacing' is the spacing between connections along the rails. 2. 'Max Trib Area' is the product of the'Max Connection Spacing' and 1/2 the panel width/height perpendicular to the rails. (2) rails per row of panels. Length or panels perpindicular to the rails shall not exceed 67". 3. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag screw. Embedment in sheathing or other material is not effective.The length of the tapered tip is not part of the embedment length. JOB NO.: U2782.1000.201 41 / E C T O R SUBJECT: GRAVITY LOADS E n C i n E E R s PROJECT: William Benham Residence CALCULATE ESTIMATED GRAVITY LOADS Roof Pitch: 7.8 :12 Design material Increase due to Material weight ROOF DEAD LOAD (D) weight [psf] pitch [psf] Composite Shingles 2.4 1.19 2.0 1/2" Plywood 1.2 1.19 1.0 Framing 3.0 3.0 Insulation 0.5 0.5 1/2" Gypsum Clg. 2.4 1.19 2.0 M, E & Misc 1.5 1.5 Total Original Roof DL 11.0 PV Array DL 3.3 1.19 3 ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf] 20 ASCE 7-10, Table 4-1 Roof Live Load With PV Array [psf] 0 2015 WBC, Section 1607.12.5 SNOW LOAD (S): Existing w/Solar Array Roof Slope [x:12]: 7.8 7.8 Roof Slope [°]: 33 33 Snow Ground Load, pg [psf]: 15 15 ASCE 7-10, Section 7.2 Terrain Category: C C ASCE 7-10, Table 7-2 Exposure of Roof: Fully Exposed Fully Exposed ASCE 7-10, Table 7-2 Exposure Factor, Cs: 0.9 0.9 ASCE 7-10, Table 7-2 Thermal Factor, Ct: 1.1 1.1 ASCE 7-10, Table 7-3 Risk Category: II II ASCE 7-10, Table 1.5-1 Importance Factor, Is: 1.0 1.0 ASCE 7-10, Table 1.5-2 Flat Roof Snow Load, pf [psf]: 10 10 ASCE 7-10, Equation 7.3- Minimum Roof Snow Load, pm [psf]: 25 25 ASCE 7-10, Section 7.3.4 Unobstructed Slippery Surface? No Yes ASCE 7-10, Section 7.4 Slope Factor Figure: Figure 7-2b Figure 7-2b ASCE 7-10, Section 7.4 Roof Slope Factor, Cs: 1.00 0.62 ASCE 7-10, Figure 7-2 Sloped Roof Snow Load, ps [psf]: 10 6 ASCE 7-10, Equation 7.4- Design Snow Load, S [psf]: 25 25 JOB NO.: U2782.1000.201 SUBJECT: MEMBER FORCES ., '' E n G I n E E R S PROJECT: William Benham Residence DESIGN LOADS IPSF1: Load Types: Snow Live Dead (D+S)/Cd (D+Lr)/Cd Max Load Existing Roof 25 20 11 31 25 31 Proposed PV Array 25 0 14 34 15 34 (Cd=Load Duration Factor=0.9 for D, 1.15 for S,and 1.25 for Lr) Label manufactured trusses Length 29.192 Existing Proposed Check M(ft-lb) 6662 6838 103% OK Existing Proposed Check [V(lb) 913 , 959 105% OK The gravity loads,and thus the stresses of the structural elements,in the area of the solar array are either decreased or increased by no more than 5%.Therefore,the requirements of Section 807.4 of the 2015 IEBC are met and the structure is permitted to remain unaltered. Existing Loads(Distributed) LOAD(LB) Add'I Add'I 80 _ -EXISTING •--- -PROPOSED Live Dead - ----_ , Roof Load Load Bm wt Cond Trib(ft) (plf) (plf) (pif) wLL(PIO woL(plf) 40 - ii 1 2.00 0 0 0 43.5 19.1 I 20 - Proposed Loads(Distributed) 0 0 10 20 30 40 Dist to Length Load 'a' of Load A Wu_ SHEAR(LB) Cond (ft) 'b'(ft) (plf) A wDL(plf) 1500 2 0.0 12.1 0.0 4.8 -EXISTING -=-- PROPOSED 3 1000 ,� 4 500 �� 0 - , 5 -500 0 5 10 15 25 30 35 6 1000 _. Proposed Loads as Point Loads -1500 Point Point MOMENT(FT-LB) Live Dead 8000 Dist'a' Load Load —•EXISTING PROPOSED Cond (ft) 'PLL'(lb) ?DC(lb) 6000 - 7 4000 8 g 2000 10 0 11 0 5 10 15 20 25 30 35 A 1 B 1 C 1 D 1 E 1 F 1 G 1 H \/ECTOF� AERIAL VIEW ELECTRICAL NOTES GENERAL NOTES en o I n e e a s ' g 1. WHERE ALL TERMINALS OF THE 1. PRIOR TO THE COMMENCEMENT OF ANY 651 IV.GALENA PARK BLVD.STE. IOI PHONE(80II 990-1775 Uw . - -- 3:s - DISCONNECTING MEANS MAY BE WORK, THE CONTRACTOR SHALL NOTIFY r DRAPER, TAH 84020 wlv .vEaTORSE,ao,H ' � �- ; ., ENERGIZED IN THE OPEN POSITION, A �,IND ' THE DESIGNER OF ANY DISCREPANCIES �t,S NOS ors t � L n SIGN WILL BE PROVIDED WARNING OF WITH THE DESIGN IN ANY CAPACITY. y►�' pF WASj1 i rev t- , r g si s THE HAZARDS. (PER ART. 690.17) ESPECIALLY RECOMMENDATIONS, CODES, / � `` -1 f f; s 2. EACH UNGROUNDED CONDUCTOR OF . R , ,1 OR REGULATIONS &RULES OF THE ti `' ray - , y , 1, � `4 THE MULTIWIRE BRANCH CIRCUIT WILL AUTHORITY HAVING JURISDICTION, WHICH �f �v Y 'a BE IDENTIFIED BY PHASE AND SYSTEM. SUPERSEDED THE NEC. w% Y ; 3 , , � tk- (PER ART. 210.5 ` n 51'r rq �`ttr - ,' ) 2. ALL DIMENSIONS TO BE VERIFIED BY �,n 'URAL 6� -i°' � ::. � .' a .e r. `'^`° CONTRACTOR PRIOR TO COMMENCEMENT ,,�, r�� k �s• 3. A NATIONALLY RECOGNIZED TESTING to,s, ONAL NG% _ 4' l . 3 zt LABORATORY SHALL LIST ALL OF WORK. '� • �_ •= i EQUIPMENT IN COMPLIANCE WITH • 3. CONTRACTOR IS RESPONSIBLE FOR ALL ° � ARTICLE 110.3. SAFETY PRECAUTIONS, OSHA 07/08/2020 mbe 4. ALL WIRES SHALL BE PROVIDED WITH REQUIREMENTS ETC. FOR THE SITE, ND N Firm License Number: 2202 r�VSE Project Number:U2782-1000-201 + STRAIN RELIEF AT ALL ENTRY POINTS INCLUDING EXISTING SITE HAZARDS. Vector Structural Engineering has reviewed the existing structure r_� '� s' INTO BOXES AS REQUIRED BY UL LISTING with loading from the solar array and lag screw connections to the 4 --- � � 4. SYSTEM IS GRID INTERACTIVE/INTERTIED existing framing.The design of the racking system,connections, =: 5. MODULE FRAMES SHALL BE GROUNDED VIA A UL LISTED POWER-CONDITIONING and all other structure is by others.Mechanical,architectural,and _ AT THE UL-LISTED LOCATION PROVIDED INVERTER. all other nonstructural aspects of the design are by others. 4, «.. € ,ssr_ .,;1.,-:" g, BY THE E MANUFACTURER USING Electrical is by others,unless stamped by Dean Levorsen. �" � b 5. SYSTEM HAS NO ENERGY STORAGE OF x �= UL-LISTED GROUNDING HARDWARE. ANY KIND, OR UPS. 6. MODULE FRAMES, RAIL, AND POSTS 6. ALL SOLAR MOUNTING FRAMEWORK TO �+& �fi SHALL BE BONDED WITH EQUIPMENT BE GROUNDED. "-a.- Y GROUND CONDUCTORS AND GROUNDED 7. FOLLOW MANUFACTURERS SUGGESTED s.-1 I 4 "-� AT THE MAIN ELECTRICAL PANEL. .-". 1 INSTALLATION PRACTICES AND WIRING - .� �� '` 7. THE DC GROUNDING ELECTRODE SPEC(�Fl ' Q /� �� r M CONDUCTOR SHALL BE SIZED 8. ALL WORK B�EIN�G�C31�9AI WILj co RESIDENCE PHOTO ACCORDING TO ARTICLE 250.166B & THE INT� AL��1 I GOODS. — 690.47. t$�IL. i�li DEPT; 9. ALL ELE ,� A E. ,+�",OBE IN COMPLI ' t dL�PAt� S — PERMIT ELECTRIC CODE (NEC). g(a�_ZOZa —G 2. s ` ADDRESS: 3 5 3 ��ij �' ' -- 0 \ APPROVED BY: -�,�®�/ L- -- i kk ', f SUBJECT TO FIELD INSPECTION. APPROVED PLAN41. 4 �� F SHALL S.;) _'" -� L NOT BE ALTERED WITHOUT AUTHORIZATION. SHEET INDEX , 1 1 .. , i i - PV 1 COVER PAGE PV 5 MOUNTING DIAGRAM I 4111/, PV 2 SITE PLAN PV 6 PLACARD cri '�., I , t: . PV 3 ELECTRICAL DIAGRAM CUT SHEETS ATTACHED `�_ — I PV 4 MOUNTING CHIKO t DRAWN BY: DRAWING SCALE: CONFIDENTIAL-THE INFORMATION CONTAINED KAM CUSTOM ,} IN THIS PACKET AND SUBSEQUENT CUTSHEETS William Benham DATE: DESIGN SOLGcN SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 7/8/2020 SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 POWER THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE# • CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 3513 W 2nd St., Anacortes, WA 98221 . RESPECTIVE EQUIPMENT,WITHOUT WRITTEN PV 1 CONSENT FROM SOLGEN POWER. A I B I C I D I E I F I G 1 H INDEX: N SYSTEM SIZE: 3.0kW TRUSS SPACING: 24" O.C. NUMBER OF MODULES:10 TRUSS SIZE: 2" x 4" ., ,' COMP. SHINGLE MODULE TYPE;SUNTECH W = E STP300S-20/Wfb _ ifi io• UTILITY OFFSET: 95% 0 S o INVERTER: Hoymiles Series (N IV MODULES O 1 O 0 UTILITY METER n O - 1 I I l'°i O MAIN SERVICE 0 1 O � � � O O o COMBINER BOX n co � ° co O AC DISCONNECT 5 � Al 0 '� 0 0 v ' o _ — o �j 0 Vector Structural Engineering has reviewed the existing structure VECTOR with loading ag from the solar arrayof and lag sg rew connections t the existing framing.The design of the racking system,connections, and all other structure is by others.Mechanical,architectural,and E f1 9 I fl E E R S all other nonstructural aspects of the design are by others. Electrical is by others,unless stamped by Dean Levorsen. 657 W.GALENA PARK BLVD.STE. 701 PHaNE(H0 7)990-1 775 DRAPER, UTAH @4020 WWW.VECTCRsE.CCM .l;1 vs L1ND ,Ho 4 P ' ' le oty ' P-% -- .4 - I0 ot,, . i 3 4S,k, AL 6�G` to O 2 07/08/2020 `� Firm License Number: 2202 3' OFFSET VSE Project Number:U2782-1000-201 CIRCUIT 1 ////, DRAWN BY: DRAWING SCALE: CONFIDENTIAL-THE INFORMATION CONTAINED KAM 1/8" = 1'-0" IN THIS PACKET AND SUBSEQUENT CUTSHEETS William Benham DATE: DESIGN �/ • S O L G c N SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER />_ ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 7/8/2020 . - SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO,WA 99301 1 POWER THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE# CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 3513 W 2nd St., Anacortes, WA 98221 . RESPECTIVE EQUIPMENT,WITHOUT WRITTEN P\/CONSENT FROM SOLGEN POWER. A I B I C I D I E I F I G I H MAX AC OPERATING CURRENT CALCS FOR MI-1000 MAX AC OPERATING TOTAL LOAD CALCS-TOTAL AMPS AVAILABLE #OF MICROINVERTERS MAX OUTPUT CURRENT MAX AC OPERATING CURRENT CURRENT FOR MI-1000&500 BUS RATING 120% TOTAL MAIN BREAKER MAX BREAKER SIZE 2 X 4.16A = 8.32A MI-1000 MI-500 200A X 1.2 = 240 - 200A = 40A MAX AC OPERATING CURRENT CALCS FOR MI-500 #OF MICROINVERTERS MAX OUTPUT CURRENT MAX AC OPERATING CURRENT 8.32A + 2.08A = 10.40A COMBINER BOX PANEL SIZE CALCS 1 X 2.08A = 2.08A NUMBER OF NUMBER OF NORM INAL OUTPUT COMBINED CIRCUIT# MODULES MICROINVERTERS CURRENT TOTAL 125% TOTAL TOTAL BREAKER SIZE BREAKER SIZE CALCS CIRCUIT 1 (1 of 2). 2 2 X 1.04A = 2.08A x 1.25 = 2.60A = 13.00A = 15A MAX AC OPERATING CURRENT 125% TOTAL BREAKER SIZE CIRCUIT 1 (2 of 21 8 2 X 4.16A = 8.32A x 1.25 = 10.40A 10.40A X 1.25 = 13.00A = 15A NOTES: 1. UTILITY METER GLOBE ONLY. (EXISTING) 2. 200A MAIN SERVICE PANEL. (EXISTING) — 3. 60A RATED FUSED AC UTILITY DISCONNECT WITH (2) 15A FUSES. (NEW) 4. PRODUCTION METER. (NEW) 5. 125A RATED COMBINER PANEL. (NEW) N N UTILITY METER(E) 4 )------.........""- CIRCUIT#1 (1 of 2) -2 SUNTECH CIRCUIT#1 (2 of 2) - 8 SUNTECH C1STP300S-20/WFB MODULES STP300S-20/WFB MODULES KOI \GRIDE UTILITY WITH HOYMILES MI-250 MICRO WITH HOYMILES MI-1000 MICRO (2)6AWG ) — INVERTERS INVERTERS (1)8AWGEGC 3 — o l N ` (2)6 AWG (2- • • • (�1 (8. • • • (� ( b (1)6 AWG NEUTRAL (2)._\ EXISTING ( (2WIRE /—MA1N SERVICE PANEL(E) (2)12 AWG • • • • • • (1)8 AWG EGC SUPPLY-SIDE INTERCONNECTION co _ NEC 705.12(A) W r WITH ILSCO CLAMPS XI _i _ _ • VERIFY CONDUCTOR SIZE, 4/0 AL � / OR 2/0 CU �/ 00A MAIN SERVICE DISCONNECT(E) I (2)6 AWG — MAIN (1)B AWG EGC I L (1)B AWG EGC J 'I' -4. .p DRAWN BY: DRAWING SCALE: CONFIDENTIAL - THE INFORMATION CONTAINED KAM NOT TO SCALE IN THIS PACKET AND SUBSEQUENT CUTSHEETS William Benham DATE: DESIGN t'- . -_ _ SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 7/8/2020 fi SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 993011 :+ :�� POWER THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE# CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 3513 W 2nd St. , An a co rtes , WA 98221 RESPECTIVE EQUIPMENT, WITHOUT WRITTEN CONSENT FROM SOLGEN POWER. PV 3 A I B I C I D I E I F I G I H 5.5, 13.4' r ���®� 3.3' 0.67" EP7 G l fl E E R B ' (/ ' 65 r W.GALENA PARK BLVD.STE. 101 PHONE r90 11 990-1 775 _ I 1 DRAPER, UTAH 84020 WWW.VECTORSE.COM ! ' I I • I • ' vs LAND Not ''��oF WAsy'M ay 4 - ,,,:. o 4 , . ..4 i , ,i 11.1 I 9 In — i .4.0, ' sv'i ' if — .• — c 510i, 4, L FEETAMI ssf0NAL��G L0 P � 07/08/2020 N N - Firm License Number: 2202 VSE Project Number:U2782-1000-201 ::)'''''. - 7# Rail -- — FLASHING 1 � _ Vector Structural Engineering has reviewed the existing structure with loading from the solar array and lag screw connections to the existing framing.The design of the racking system,connections, , . _ and all other structure is by others.Mechanical,architectural,and all other nonstructural aspects of the design are by others, • iN. Electrical is by others,unless stamped by Dean Levorsen. IL H _____ ,,, ___, co C.J z. 14 r;. f1, STRUCTURAL NOTES: - - Mount to Existing Rafters 1. TOTAL SYSTEM WEIGHT(MODULE&RAIL: 4 4 ti 4 452 LBS - 2. RAIL WEIGHT:49 LBS rr~ Mid Clamp End Clamp 3. MODULE WEIGHT:403 LBS ' /J f ~" 4. DISTRIBUTED WEIGHT: 2.44 PSF _now. Ills_ 4 ,_- -_- Grounding Lug in \N_LI":--tif, 1111111111r i=If lin rr - - -teri DRAWN BY: DESIGN CONFIDENTIAL-THE INFORMATION CONTAINED KAM IN THIS PACKET AND SUBSEQUENT CUTSHEETS William Benham DATE: ' SHALL NOT BE USED FOR THE BENEFIT OF ANYONE OUTSIDE SOLGEN POWER. NEITHER SOLGEN POWER 5100 ELM RD, 7I8I2020 1 * S O L G N e.- SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 PAGE# P 0 W . E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 351 3 W 2nd St. Anacortes7 WA 98221 . RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 4 CONSENT FROM SOLGEN POWER. A I B I C 1 D I E I F G I H VECTOR e n ® I n e E R s - 410 651 W.GALENA PARK BLVD,STE. 107 PHONE(BO 11 990-1775 ,-. DRAPER, UTAH B4020 WWW.VECTORBE.COM �o.$ L1NDHot 10 ovWA% 9 y , - tii. / = 100, 4, bTUS A� R A L 64 - • SS/ONAL 6t4G\ — 20' N 07/08/2020 N Firm License Number:2202 1111 VSE Project Number: U2782-1000-201ROOF 1Vector Structural Engineering has reviewed the existing structure TI LT:33° with loading from the solar array and lag screw connections to the I!!I' o §1 existing framing.The design of the racking system,connections, AZI M UTH:249 — — and all other structure is by others.Mechanical,architectural,and , all other nonstructural aspects of the design are by others. Electrical is by others,unless stamped by Dean Levorsen. PV MODULE 34-3" MOUNTING FEET co CHIKO#7 RAIL w 2 MOUNTING DIAGRAM SCALE:NOT TO SCALE — STRUCTURAL NOTES: 1. 48" MAX SPAN OF RAIL TO DISTRIBUTE WEIGHT OVER SUPPORT OF TRUSSES 2. MOUNTING FEET ARE IN APPROXIMATE LOCATION. .l, 1.' 3. MOUNTING FEET SHOULD BE STAGGERED AS -- SHOWN IN DIAGRAM -0 --o------0-- o ---- o ROOF 2 TILT:33° — o m — 0 --0 0 o AZIMUTH:249° — 1 I 1 I 1 , N 1 26'_7' 1 In cri 1 MOUNTING DIAGRAM DRAWN BY: DRAWING SCALE: CONFIDENTIAL-THE INFORMATION CONTAINED KAM 1/8" = 1'-0" _ IN THIS PACKET AND SUBSEQUENT CUTSHEETS William Benham DATE: DESIGN __ _ SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER S SOLG a N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 7/8/2020 -'i SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 POWER THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 3513 W 2nd St., Anacortes, WA 98221 PAGE# RESPECTIVE EQUIPMENT,WITHOUT WRITTEN PV 5 CONSENT FROM SOLGEN POWER. A I B I C I D I E I F I G I H - CAUTION - POWER TO THIS BUILDING IS SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: N 3513 W 2nd St.,Anacortes,WA 98221. N N Wi�► E — *41 co SOLAR PV ARRAY WITH co MICROINVERTERS ROOF MOUNTED -14110, _ MAIN SERVICE PANEL UTILITY METER PV DISCONNECT Iri SO L G E N - POWER - 6 "x6 11 DRAWN BY: DESIGN _ CONFIDENTIAL-THE INFORMATION CONTAINED KAM IN THIS PACKET AND SUBSEQUENT CUTSHEETS William Benham DATE: SOLGEN SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 7/8/2020 ` SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 PAGE# POWER THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 3513 W 2nd St., Anacortes, WA 98221 . RESPECTIVE EQUIPMENT,WITHOUT WRITTEN PV6 CONSENT FROM SOLGEN POWER. HyPro STP305S - 20/Wfb NSUNTECH STP300S - 20/Wfb STP295S - 20/Wfb 305 Watt MONOCRYSTALLINE SOLAR MODULE Features `�\ ,, High module conversion PID resistant \ efficiency = Advanced cell technology 18.6% Module efficiency up to RePI s scant and qualified materials lead to 18.6%achieved through high resistance to PID advanced cell technology and manufacturing capabilities Positive tolerance © p Suntech current sorting • 111 Positive tolerance of up to lax© process 0/+5w 5W delivers higher outputs 2% System output maximized by reliablity reducing mismatch losses up to 2%with modules sorted& packaged by amperage Extended wind and snow Withstanding harsh et load tests ® environment 3800Pa Module certified to Harsh Reliable quality leads to a 5400Pa environment withstand extreme wind better sustainability even in (3800 Pascal) and snow harsh environment like desert, loads (5400 Pascal)* farm and coastline Certifications and standards: V vDEcc , D E nncs oe El IEC 61215,IEC61730,conformity to CE Cqq Trust Suntech to Deliver Reliable Performance Over Time Special 5 busbar design • World-class manufacturer of crystalline silicon photovoltaic modules The unique cell design leads • Unrivaled manufacturing capacity and world-class technology reduction in electrodes • Rigorous quality control meeting the highest international standards: resistance, shading area and ISO 9001:2008, ISO 14001:2004 and ISO17025:2005 raise in conversion efficiency. • Regular independently checked production process from international Residual stress distribution can be more even,reducing the accredited institute/company micro-cracks risks. • Tested for harsh environments (salt mist,ammonia corrosion and sand blowing testing:IEC 61701, IEC 62716, DIN EN 60068-2-68)*** • Long-term reliability tests • 2 x 100% EL inspection ensuring defect-free modules Industry-leading Warranty based on nominal power IP68 Rated Junction Box • 97.5%in the first year,thereafter,for The Suntech IP68 rated years two(2)through twenty-five junction box ensures an (25),0.7%maximum decrease from outstanding waterproof a °°% bndustr MODULE's nominal power output r% level, supports installations y�eadpn9linear per year,ending with the 80.7% - �,,�( - in all orientations and °% warranty in the 25th year after the defined `ia,M reduces stress on the cables. • Y �,. • 880% WARRANTY STARTING DATE.** High reliable performance, 1 10 25. 12-year product warranty low resistance connectors • 25-year linear performance ensure maximum output warranty for the highest energy production. *Please refer to Suntech Standard Module Installation Manual for details. **WEEE only for EU market. ***Please refer to Suntech Product Near-coast Installation Manual for details. ****Please refer to Suntech Product Warranty for details. ©Copyright 2019 Suntech Power WWW suntech power.corn IEC-STP-Wfb-NO1.01-Rev 2019 1'�:!7 0 STP3055 - 20/Wfb iSUN TEC STP300S - 20/Wfb SP2955 - 20/Wfb FliectTkal Characteristics SIC STP305S-20/ STP3005-20/ STP2955-20/ 992 139.11±210.081 Wfb Wfb Wfb Drainage holes 942137.11±10.041 \ _ /_Juncton box Maximum Power at STC(Pmax) 305 W 300W 295 W "' Optimum Operating Voltage(Vmp) 32.8 V 32.5 V 32.2 V Grounding holes ° Product'aheo, © Optimum Operating Current(Imp) 9.30 A 9.23 A 9.16 A 8-14X910.55X0.351 Barcode, Open Circuit Voltage(Voc) 39.8 V±5% 39.6 V±5% 39.3 V±5% Mounting slots • Short Circuit Current(Isc) 9.80 A±5% 9.72 A±5% 9.69 A±5% Module Efficiency 18.6% 18.3% 18.0% 0 o a Operating Module Temperature -40°C to+85°C ,11 A F 1A m Maximum System Voltage 1000/1500 V DC(IEC) (Back View) - Section A-A ail i Maximum Series Fuse Rating 20 A i Power Tolerance 0/+5 w �, STC:Irradiance 1000 W/m',module temperature 25°C,AM=1.5; m > Best in Class AAA solar simulator(IEC 60904-9)used,power measurement uncertainty is within+/-3% 10.611 4151 I II NMOT STP305S-20/ STP3005-20/ STP295S-20/ 3511.38] o (Front View) �� Wfb Wfb Wfb Note:mm[inch] Il II I I I II I Maximum Power at NMOT(Pmax) 228.3 W 225.0 W 221.3 W Optimum Operating Voltage(Vmp) 30.5 V 30.3 V 30.0 V Optimum Operating Current(Imp) 7.49 A 7.43 A 7.39 A Open Circuit Voltage(Voc) 37.1 V 37.0 V 36.7 V Short Circuit Current(Isc) 7.92 A 7.85 A 7.83 A NMOT:Irradiance 800 W/m',ambient temperature 20'C,AM=1.5,wind speed 1 m/s; Best in Class AAA solar simulator(IEC 60904-9)used,power measurement uncertainty is within+/-3°/• Current-Voltage &Power-Voltage Curve (305S) 12 35° Temperature Characteristics 10 -300 Nominal Module Operating Temperature(NMOT) 42±2°C -250 Temperature Coefficient of Pmax -0.39%/°C 200 Temperature Coefficient of Voc -0.34%/°C a 6 •- 3 Temperature Coefficient of Isc 0.060%/°C -150 o 4 2 `1a. )1 - 50 Mechanical Characteristics _ '`� 0 Solar Cell Monocrystalline silicon 6 inches 0 10 20 30 40 50 Votage(V) No.of Cells 60(6 x 10) -,000win,= BOOW/nr' - 600Wim=- 400W/m°-200w/m' Dimensions 1650 x 992 x 35mm(65.0 x 39.1 x 1.4 inches) Weight 18.3 kgs(40.3 lbs.) Front Glass 3.2 mm(0.13 inches)tempered glass Frame Anodized aluminium alloy . Junction Box IP68 rated (3 bypass diodes) Dealer information Output Cables 4.0 mm2(0.006 inches2),symmetrical lengths(-) 1000mm (39.4 inches)and(+) 1000 mm(39.4 inches) • Connectors MC4 compatible Packing Configuration Container 20'GP 40'HC Pieces per pallet 30 30 Pallets per container 6 28 Pieces per container 180 840 Information on how to install and operate this product is available in the installation instruction.All values indicated in this data sheet are subject to change without prior announcement The specifications may vary slightly.All specifications are in accordance with standard EN 50380.Color differences of the modules relative to the figures as well as discolorations of/in the modules which do not impair their proper functioning are possible and do not constitute a deviation from the specification. ©Copyright 2019 Suntech Power www.suntech-power.com IEC-STP-Wfb-N01.01-Rev 2019 IL H)hoymiles 05 06 H hoymiles P.1 icroinverter Model MI-1000 / MI-1200 (4X60 cells/ 4X72 cells) 4 in 1 unit Input Data(DC) Recommended input power(W) Up to 310/380 (Single panel) Peak power MPPT voltage range (V) 27-48/32-48 Start-up voltage(V) 22 ( Operating voltage range (V) 16-60 I I Maximum Input voltage (V) 60 40 it) q Maximum input current(A) 10.5Ax4 '4 Output Data (AC) @208V AC @240V AC @230V AC - 1 Rated output power(W) 1000/1200 1000/1200 1000/1200 14 I 1 Rated output current(A) 4,81/5,76 4.16/5 4.35/5.22 Nominal output voltage/range (V) 208/183-250 240/211-264 230/180-275 Nominal frequency/range(Hz) 60/59.3-60.5 60/59,3-60,5 50/45-55 Power factor >0.99 >0.99 >0,99 Output current harmonic distortion <3% <3% <3% Maximum units per 20A branch 3/3 4/3 4/3 r Efficiency CEC peak efficiency 96,50% / CEC weighted efficiency 96.00% ' Nominal MPPT efficiency 99.80% _-+( Night time power consumption (mW) <50 Mechanical Data I Ambient temperature range CC) -40-+65 Operating temperature range(°C) -40-+85 Dimensions (WxHxD mm) 280x176x33 Weight(kG) 3.75(including 1.9m AC cable) IdI I—1 000 I F/I I.—1 200 Enclosure rating NEMA6(IP67) Cooling Natural convection-No fans "The World's First Single-Phase Microinverter" designed for 4 solar panels with dual MPPT, with wide DC Loading Quantity input operating voltage range (16-60V) and low start-up voltage (22V only). Container 1X20'GP 1X40'GP/1X40'HQ Pallet No. 10 22 Carton No. 360 756 Hoymiles 4 in 1 microinverter MI-1000/MI-1200 is "The Best Power Density Microinverter" ever in the Total Quantity 1800 3780 solar industry with extremely light weight-only 3.75kG including integrated DC &AC cables; 3-phase Other Features wiring makes it easy to be configured by Hoymiles 4 in 1 microinverter for MW size commercial PV power Communication Wireless Design lifetime >25 years stations (one of the world's biggest microinverter projects configured by Hoymiles microinverter is 3.6MW). Standard Compliance 1 EMC EN61000-6-3:2007+A1:2011 EN61000-6-2:2005EN61000-3-2:2014 1119 ' hts EN62109-1:2010E Safety EN62109-1:2010EN62109-2:20111EC 62109-1 Ed 1.OIEC 62109-2 Ed 1.0 UL Std No.1741-Second EditionEN 60529 • Maximum output power up to 1000/1200W;Adapted to 60 &72 cells PV panels On-Grid AS/NZS 4777.2:2015VDE-AR-N4105:2011-08DIN V VDE V 0126-1-1/A1:2012:02 • Peak efficiency 96.5%; CEC weighted efficiency 96.0% IEC61727:2004EN504382013ANSI/IEEE 1547.11EC62116:2011 UTE C 15-712-1:2010-07 NBT32004-2013 • Static MPPT efficiency 99,8%; Dynamic MPPT efficiency 99.76% in overcast weather • High reliability: NEMA6 (IP67) enclosure ; 6000V surge protection "� p T e)' ) AAA ����� ( E FC A. G83 c us' u�° INMETNO H hoymiles 07 08 H hoymiles • icroinverter MI-500 / MI-600 / MI-700 Model (2X60 cells/ 2X72 cells) 2 in 1 unit Input Data(DC) Recommended input power(W) Up to 310/380/400 (Single panel) Peak power MPPT voltage range (V) 27-48/29-48/33-48 1 - Start-up voltage(V) 22 1 Operating voltage range (V) 16-60 Maximum Input voltage (V) 60 * • * 0 o Maximum input current (A) 10.5/11,5/11,5 Output Data (AC) @208V AC @240V AC @230V AC N 4 -. - Rated output power(W) 500/600/700 500/600/700 500/600/700 (�� Rated output current(A) 2.40/2.88/3.36 2,08/2.50/2.91 2.17/2,61/3.04 Nominal output voltage/range (V) 208/183-250 240/211-264 230/180-275 Nominal frequency/range (Hz) 60/59.3-60.5 60/59.3-60,5 50/45-55 Power factor >0.99 >0.99 >0.99 Output current harmonic distortion <3% <3% <3% Maximum units per 20A branch 6/5/4 7/6/6 7/5/5 Efficiency JCEO peak efficiency 96.7% CEC weighted efficiency 96,5% * Nominal MPPT efficiency 99.8% Night time power consumption (mW) <50 0 Mechanical Data Ambient temperature range (CC) -40-+65 Operating temperature range CC) -40-+85 Dimensions (WxHxD mm) 250x170x28 M I-500 I I /1 I-6 0 0 / Ftil I-7 0 0 Weight(kG) 3.00(including 1,9m AC cable) Enclosure rating NEMA6(IP67) "The World's First Daisy-Chain 2 in 1 Microinverter for Large Scale Commercial Application" is designed Cooling Natural convection-No fans for dual solar panels with double MPPT, and wide DC input operating voltage range (16-60V) and low Loading Quantity start-up voltage (22V only). Container 1 X20'GP 1 X40'GP/1 X40'HQ Pallet No. 10 22 Carton No, 480 1008 Hoymiles 2 in 1 microinverter MI-500/MI-600/MI-700 is the world's most powerful microinverter solution for Total Quantity 2400 5040 dual solar panels with CEC weighted efficiency as high as 96.5% (world's No,1 for 2 in 1 unit in 2015); with Other Features quicker installation and much higher power density compared with single unit, it's also one of the best-selling Communication Wireless microinverters for Hoymiles up to now worldwide. Design lifetime >25 years Standard Compliance EMC EN61000-6-3:2007+A1:2011 EN61000-6-2:2005EN61000-3-2:2014 Iii x EN61000-3-3:2013 Safety EN62109-1:2010EN62109-2:2011 IEC 62109-1 Ed 1,01EC 62109-2 Ed 1.0 UL Std No.1741-Second EditionEN 60529 • Maximum output power up to 500/600/700W;Adapted to 60 &72 cells PV panels On-Grid AS/NZS 4777,2:2015VDE-AR-N4105:2011-08DIN V VDE V 0126-1-1/A1:2012:02 • Peak efficiency 96.7%; CEC weighted efficiency 96.5% IEC61727:2004EN50438:2013ANS1/IEEE 1547,11EC62116:2011 UTE C 15-712-1:2010-07 • Static MPPT efficiency 99.8%; Dynamic MPPT efficiency 99.76% in overcast weather NBT32004-2013 • High reliability: NEMA6 (IP67) enclosure; 6000V surge protection S Cla: PA:4-.3 ° ``P ( E FC T.►. G83 C Us INIdE7710 ! I ( • w www.chikolancom/www.chikosolaracom Solar Mounting Solutions PRODUCT LINE Item Product Name CK-FTH-21 1 CHIKO AL Roof Hook 211 I TECHNICAL DATA Main Material 6005-T5 & SUS304 '° ° ,, Uplift P N*Fv (N=3) av '` rr` Wind Load Up to 60 M/S Snow Load 1 .4 KM/M2 Hook Spacing Up to 2000mm Installation Site Roman Tile Roof AL Roof Hook 019 1IfL. 0. CHIKO L Feet matching to the Flashing,supplying the best waterproofing _� i' solution for Asphalt Shingles Roofs. �s ADVANTAGES COMPONENT LIST WARRANTY Enables simple, fast and cost-effective MATERIAL QTY installation. AL Flashing 01 \'�yrY G�j ■ High class anodized aluminium. AL L Feet 01 A. 0''1 0 s ® Fasteners and rail nut configurated to 050 Nut 01 YEARS SUS Bolt M8*25 01 ,„.(o., save extra parts purchasing. SUS M8 Wahser 02 ■ 100% water proofing. Wooden Screw M8*90 01 Silicon Rubber 01 UL LISTED (TI' VI ORDERING SPECIFICS C ■ US us Standard Packaging 16PCS/CTN &/STEO Dimensions 34X25X7CM LISTED Intertek [PV MOUNTING SYSTEM] fltert 0 Weight 6KG 50101 E483644 Conforms to UL STD NO.2703 Phone:86-21 -59972267-801 Fax:86-21-59972938, 111111111 C H 114i. www.chikolancom/www.chikosolaracom Solar Mounting Solutions PRODUCT LINE Item Product Name CK-7R-2100 CHIKO 7 RAIL 2100MM CK-7R-3200 CHIKO 7 RAIL 3200MM CK-7R-4200 CHIKO 7 RAIL 4200MM TECHNICAL DATA Main Material AL 6005-T5 Wind Velocity Up to 60 M/S 30.8 Xi=31918.082 mm4 - L Yi=81501 .592 mm4 7 FLAIL L CHIKO 7R aluminium rail is designed for o roof mounting system, it could applied on all roof mount system. d- r-L-- 31.3 ADVANTAGES COMPONENT LIST WARRANTY ■ Easy installation MATERIAL QTY ® Highclass anodized Aluminium Rail 01 �P 9 1 0.4i- Tilt- in nut YEARS Universal on roof mount system ORDERING SPECIFICS Standard Pack aging 8 PCS/P KG Uf2ii\ Dimensions 2100/3200/4200mm C ® L USIV/us Weight 15/22.8/30KG sTE LISTED Intertek [PV MOUNTING SYSTEM] 5010190 E483644 Conforms to UL STD NO.2703 Phone:86-21-59972267-801 Fax:86-21-59972938 Cwww.chikolar.com/www.chikosolar.corn Solar Mounting Solutions PRODUCT LINE Item Product Name CK-FT-SKA CHIKO 7 Rail Splice Kit TECHNICAL DATA Main Material AL 6005-T5 Wind Load Up to 60 M/S Snow Load 1 .4 KM/M2 7 RAIL SPLICE KIT Zoec' 45.7mm CHIKO 7R aluminium rail splice kit is designed for 7R rail connection from back to position. The most simple and handy installation way. .r if 0 ADVANTAGES COMPONENT LIST WARRANTY Easy installation MATERIAL OTY l�lty co' Aluminium Rail Splice Kit 01 Highclass anodized q� � 0 � SUS304 Bolt M8*25 02 YEARS Star Washer 02 :a P,I Lil L ._. TED ORDERING SPECIFICS Standard Packaging 200 PCS/PKG �M Dimensions 51X38X22CM C US us Weight 30KG Lts�o LISTED Intertek [PV MOUNTING SYSTEM] 5010190 E483644 Conforms to UL STD NO.2703 Phone:86 21 59972267-801 Fax:86-21-599 7 2938 i,. C H I 11•4 www.chiko lar.com/www.chikousa.com Solar Mounting Solutions PRODUCT LINE 411C40 Item Product Name CK-FTM-K30 CHIKO Intergated Grounding Mid Clamp 30mm CK-FTM-K33 CHIKO Intergated Grounding Mid Clamp 33mm CK-FTM-K35 CHIKO Intergated Grounding Mid Clamp 35mm CK-FTM-K38 CHIKO Intergated Grounding Mid Clamp 38mm CK-FTM-K40 CHIKO Intergated Grounding Mid Clamp 40mm t4t:''' ' ... ab TECHNICAL DATA Main Material AL 6005-T5 Intergated Grounding O Mid Clamp o CHIKO end clamps is designed base on 7R rail to fix module on the end of rail, have D=30/ 1 - � founction of intergated grounding, 30mm � .`.♦' to 50 mm thickness module are available. �*v ADVANTAGES COMPONENT LIST WARRANTY ® Intergated Grounding MATERIAL QTY E Easy installation Mid Clamp 01 ,,,\.91.1 GU9�. Q" 4 9 Hi h class anodized SUS304 Bolt M8 01 o;x1 O g 050 SUS304 Nut 01 cooaRs Tilt- in nut -,% Rivet 02 UL LISTED ORDERING SPECIFICS U Dimensions Standard Packaging 100 PCS/BOX 400PCS/CTN C ok us us 50X38X20CM ►s�o LISTED Intertek Weight 26.8/27.5/28/28.6KG [PV MOUNTING SYSTEM] 5010190 E483644 Conforms to UL STD NO.2703 Phone:86-21 -59972267-801 Fax:86-21-59972938 C 1 I( www.chikolar.com/www.chiko ` -_:_ _ Solar Mounting Solutions r - PRODUCT LINE Item Product Name CK-I-I E-K30 CHIKO Intergated Grounding End Clamp 30mm CK-FTE-K33 CHIKO Intergated Grounding End Clamp 33mm CK-FTE-K35 CHIKO Intergated Grounding End Clamp 35mm CK-FTE-K38 CHIKO Intergated Grounding End Clamp 38mm CK-FTE-K40 CHIKO Intergated Grounding End Clamp 40mm TECHNICAL DATA Main Material AL 6005-T5 Intergated Grounding c) End Clamp -7— �c� _ '- - /35/38/40/45/50 CHIKO end clamps is designed base on %4‘....S 7R rail to fix module on the end of rail, have founction of intergated grounding, 30mm to 50mm thickness module are available. 4: 4, *ivy ADVANTAGES COMPONENT LIS7 WARRANTY • Intergated Grounding MATERIAL QTY End Clamp 01 �l�s1"GUI. • Easy installation I � r • High class anodized SUS304 Bolt M8*25 01 YE 0 ARS ,,, SUS304 Washer M8 01a:- ■ Tilt- in nut 050 SUS304 Nut 01 Rivet 01 UL LISTED ORDERING SPECIFICS U ao, DimensioStandard Packaging 100 PCS/BOX 400PCS/CTN C o L usus i ons 50X38X20CM /STE LISTED intertek Weight 22/24.5/25.5/26KG RV MOUNTING SYSTEM] 5010190 E483644 Conforms to UL STD NO.2703 Phone:86-21-5997226 7-801 Fax:86-21-599 7 2938 HyPro STP305S - 20/Wfb JrSUNTECH STP300S - 20/Wfb STP295S - 20/Wfb 305 Watt MONOCRYSTALLINE SOLAR MODULE Features �, ,, High module conversion PID resistant Arz\ efficiency = Advanced cell technology o Module efficiency up to PID and qualified materials lead to 18.6/0 18.6%achieved through Resistant high resistance to PID advanced cell technology and manufacturing capabilities Positive tolerance © B Suntech current sorting .•I I I Positive tolerance of up to Bx© process 0/+5w 5W delivers higher outputs 2% System output maximized by reliablity reducing mismatch losses up to 2%with modules sorted& packaged by amperage Extended wind and snow Withstanding harsh rt load tests ® environment 3800Pa Module certified to Harsh Reliable quality leads to a 5400Pa environment withstand extreme wind better sustainability even in (3800 Pascal) and snow harsh environment like desert, / loads (5400 Pascal)* farm and coastline Certifications and standards: D VE 11. 7"E, c E 0 IEC 61215,IEC 61730,conformity to CE CS o(4i -- l O Trust Suntech to Deliver Reliable Performance Over Time Special 5 busbar design • World-class manufacturer of crystalline silicon photovoltaic modules The unique cell design leads • Unrivaled manufacturing capacity and world-class technology reduction in electrodes • Rigorous quality control meeting the highest international standards: resistance, shading area and ISO 9001:2008, ISO 14001:2004 and ISO17025:2005 raise in conversion efficiency. • Regular independently checked production process from international Residual stress distribution can accredited institute/company be more even,reducing the • Tested for harsh environments (salt mist,ammonia corrosion and sand micro-cracks risks. blowing testing:IEC 61701,IEC 62716, DIN EN 60068-2-68)*** • Long-term reliability tests • 2 x 100% EL inspection ensuring defect-free modules Industry-leading Warranty based on nominal power IP68 Rated Junction Box • 97.5%in the first year,thereafter,for The Suntech IP68 rated years two(2)through twenty-five junction box ensures an (25),0.7%maximum decrease from outstanding waterproof a °,- •Industry,e MODULE's nominal power output / level, supports installations 9]5°5 ad'nglinear per year,ending with the80.7% in all orientations and ▪ 90% warranty in the 25th year after the defined reduces stress on the cables. • 88'% WARRANTY STARTING DATE.* * High reliable performance, 3 1 10 25. 12-year product warranty low resistance connectors • 25-year linear performance ensure maximum output warranty for the highest energy production. *Please refer to Suntech Standard Module Installation Manual for details. **WEEE only for EU market. ***Please refer to Suntech Product Near-coast Installation Manual for details. ****Please refer to Suntech Product Warranty for details. ©Copyright 2019 Suntech Power WWW.sunte'chrp9wer.com IEC-STP-Wfb-NO1.01-Rev 2019 gym. STP305S - 20/Wfb r� - "_:-_,UN TECH STP300S o 20/Wfb STP2955 - 20/Wfb Electrica9 Characteristics STC STP305S-20/ STP300S-20/ STP2955-20/ 992[39.11±210.08] Wfb Wfb Wfb Drainage holes _ 942[37.110[0.04] \ -Jun°6°nb°X Maximum Power at STC(Pmax) 305 W 300 W 295 W 8-�s.ltmosl , ® "y Optimum Operating Voltage(Vmp) 32.8 V 32.5 V 32.2 V Grounding holes ° Product labeF� a, ® Optimum Operating Current(Imp) 9.30 A 9.23 A 9.16 A 8-14x9[os5Xo.351 Barcode- Open Circuit Voltage(Voc) 39.8 V±5% 39.6 V±5% 39.3 V±5% Mounting slats Short Circuit Current(Isc) 9.80 A±5% 9.72 A±5% 9.69 A±5% Module Efficiency 18.6% 18.3% 18.0% o Operating Module Temperature -40°C to+85°C AF lA T. 4 o Maximum System Voltage 1000/1500 V DC(IEC) (Back View) m LA Section A-A il I m N Maximum Series Fuse Rating 20 A m rn ® a Power Tolerance 0/+5 W LI ' u- STC:Irradiance 1000 W/m',module temperature 25°C,AM=1.5; „., o Best in Class AAA solar simulator(IEC 60904-9)used,power measurement uncertainty is within+/-3% ° V 10.610,4151 I II NMOT STP3055-20/ STP300S-20/ STP295S-20/ 35[1.38] r I (Front View) Wfb Wfb Wfb Note:mm[inch] -_ I-.�-�j�l --- I-ljU I - =_� Maximum Power at NMOT(Pmax) 228.3 W 225.0 W 221.3 W . Optimum Operating Voltage(Vmp) 30.5 V 30.3 V 30.0 V Optimum Operating Current(Imp) 7.49 A 7.43 A 7.39 A • Open Circuit Voltage(Voc) 37.1 V 37.0 V 36.7 V Short Circuit Current(Isc) 7.92 A 7.85 A 7.83 A NMOT:Irradiance 800 W/m',ambient temperature 20°C,AM=1.5,wind speed 1 m/s; Best in Class AAA solar simulator(IEC 60904-9)used,power measurement uncertainty is within+/-3% Current-Voltage& Power-Voltage Curve (305S) 12 350 Temperature Characteristics 10 -300 Nominal Module Operating Temperature(NMOT) 42±2°C j -250 Temperature Coefficient of Pmax -0.39%/°C 200 Temperature Coefficient of Voc -0.34%/°C L a 6 _ , §. Temperature Coefficient of Isc 0.060%/°C - 150 p U 4 i 100 `\ 11 Mechanical Characteristics 0 0 Solar Cell Monocrystalline silicon 6 inches 0 10 20 30 40 s0 i. Votage(V) No.of Cells 60(6 x 10) -1000W/rn' 300W/m' 600w/m=�-_ 400W/m'®200W/m' Dimensions 1650 x 992 x 35mm(65.0 x 39.1 x 1.4 inches) Weight 18.3 kgs(40.3 lbs.) Front Glass 3.2 mm(0.13 inches)tempered glass Frame Anodized aluminium alloy Junction Box IP68 rated(3 bypass diodes) Dealer information Output Cables 4.0 mm2(0.006 inches2),symmetrical lengths(-) 1000mm (39.4 inches)and(+) 1000 mm(39.4 inches) Connectors MC4 compatible Packing Configuration Container 20'GP 40'HC Pieces per pallet 30 30 Pallets per container 6 28 Pieces per container 180 840 Information on how to install and operate this product is available in the installation instruction.All values indicated in this data sheet are subject to change without prior announcement.The specifications may vary slightly.All specifications are in accordance with standard EN 50380.Color differences of the modules relative to the figures as well as discolorations of/in the modules which do not impair their proper functioning are possible and do not constitute a deviation from the specification. ©Copyright 2019 Suntech Power www.suntech-power.com IEC-STP-Wfb-NO1.01-Rev 2019 H hoymiles 05 06 N hoymiles Ma jil icroirivt- i','' L'. MI-1000 / MI-1200 Model (4X60 cells / 4X72 cells) 4 in 1 unit Input Data(DC) . _ Recommended input power (W) Up to 310/380 (Single panel) Peak power MPPT voltage range (V) 27-48/32-48 Start-up voltage(V) 22 Operating voltage range(V) 16-60 Maximum Input voltage (V) 60 Maximum input current(A) 10,5Ax4 40 Output Data (AC) @208V AC @240V AC @230V AC Rated output power(W) 1000/1200 1000/1200 1000/1200 Rated output current(A) 4.81/5.76 4,16/5 4.35/5.22 JINI Nominal output voltage/range(V) 208/183-250 240/211-264 230/180-275 Nominal frequency/range (Hz) 60/59.3-60.5 60/59,3-60,5 50/45-55 Po; tnt er factor >0,99 >0,99 >0.99 harmonic distortion <3% <3% <3% Maximum units per 20A branch 3/3 4/3 4/3 Efficiency CEC peak efficiency 96,50% CEC weighted efficiency 96,00% 0 Nominal MPPT efficiency 99,80% 4`"-' Night time power consumption (mW) <50 Mechanical Data Ambient temperature range (CC) -40-+65 Operating temperature range (CC) -40-+85 Dimensions (WxHxD mm) 280x176x33 Weight(kG) 3.75(including 1.9m AC cable) ri/I I—1 000 / 1 /1 I-1 200 Enclosure rating NEMA6(IP67) Cooling Natural convection-No fans "The World's First Single-Phase Microinverter" designed for 4 solar panels with dual MPPT, with wide DC Loading Quantity input operating voltage range (16-60V) and low start-up voltage (22V only). Container 1X20'GP 1X40'GP/1X40'HQ Pallet No, 10 22 Carton No, 360 756 Hoymiles 4 in 1 microinverter MI-1000/MI-1200 is "The Best Power Density Microinverter" ever in the Total Quantity 1800 3780 solar industry with extremely light weight-only 3.75kG including integrated DC &AC cables; 3-phase Other Features wiring makes it easy to be configured by Hoymiles 4 in 1 microinverter for MW size commercial PV power Communication Wireless stations (one of the world's biggest microinverter projects configured by Hoymiles microinverter is 3.6MW). Design lifetime >25 years Standard Compliance EMC EN61000-6-3:2007+A1:2011 EN61000-6-2:2005EN61000-3-2:2014 Elighlights EN61000-3-3:2013 Safety EN6212109-1:2010EN62109-2,20111EC 62109-1 Ed 1,01EC 62109-2 Ed 1.0 UL Std No.1741-Second EditionEN 60529 • Maximum output power up to 1000/1200W; Adapted to 60 & 72 cells PV panels On-Grid AS/NZS4777,2:2015VDE-AR-N4105:2011-08DINVVDEV0126-1-1/A1:2012:02 • Peak efficiency 96.5%; CEC weighted efficiency 96.0% IEC61727:2004EN504382013ANSI/IEEE 1547.1 IEC62116:2011 UTE C 15-712-1:2010-07 NBT32004-2013 • Static MPPT efficiency 99.8%; Dynamic MPPT efficiency 99.76% in overcast weather • High reliability: NEMA6 (IP67) enclosure ; 6000V surge protection S�® ( Fk—W (Co; T ( E FC 7 G83 Ci US •u'. INMETfl0 - - f� _- ho miles Y 07 08 H hoymiles icroinverter MI-500 / MI-600 / MI-700 Model (2X60 cells / 2X72 cells) 2 in 1 unit ' Input Data(DC) Recommended input power(W) Up to 310/380/400 (Single panel) Peak power MPPT voltage range (V) 27-48/29-48/33-48 Start-up voltage(V) 22 Operating voltage range (V) 16-60 ® Maximum input voltage (V) 60 Maximum input current(A) 10.5/11,5/11,5 Output Data (AC) @208V AC @240V AC @230V AC I Rated output power(W) 500/600/700 500/600/700 500/600/700 N IJ �, t Rated output current(A) 2.40/2,88/3,36 2.08/2.50/2.91 2.17/2,61/3,04 ` Nominal output voltage/range(V) 208/183-250 240/211-264 230/180-275 I\4' ' - -'\ Nominal frequency/range (Hz) 60/59,3-60.5 60/59.3-60.5 50/45-55 Power factor >0,99 >0.99 >0,99 ,. Output current harmonic distortion <3% <3% <3% Maximum units per 20A branch 6/5/4 7/6/6 7/5/5 Efficiency - CEO peak efficiency 96.7% CEC weighted efficiency 96.5% Nominal MPPT efficiency 99,8% Night time power consumption (mW) <50 40 Mechanical Data Ambient temperature range (°C) -40-+65 Operating temperature range (CC) -40-+85 M I-5 0 0 / IVI I-6 0 0 / Fi1 I-7 0 0 Dimensions (WxHxD mm) 250x170x28 Weight(kG) 3.00(including 1,9m AC cable) Enclosure rating NEMA6(IP67) "The World's First Daisy-Chain.2 in 1 Microinverter for Large Scale Commercial Application" is designed Cooling Natural convection-No fans for dual solar panels with double MPPT, and wide DC input operating voltage range (16-60V) and low Loading Quantity start-up voltage (22V only). Container 1 X20'GP 1 X40'GP/1 X40'HQ Pallet No. 10 22 Carton No. 480 1008 Hoymiles 2 in 1 microinverter MI-500/MI-600/MI-700 is the world's most powerful microinverter solution for Total Quantity 2400 5040 dual solar panels with CEC weighted efficiency as high as 96.5% (world's No.1 for 2 in 1 unit in 2015); with Other Features quicker installation and much higher power density compared with single unit, it's also one of the best-selling Communication Wireless microinverters for Hoymiles up to now worldwide. Design lifetime >25 years Standard Compliance EMC EN61000-6-3:2007+A1:2011 EN61000-6-2:2005EN61000-3-2:2014 Highlights x EN61000-3-3:2013 Safety EN62109-1,2010EN62109-2i20111EC 62109-1 Ed 1,0lEC 62109-2 Ed 1.0 UL Std No,1741-Second EditionEN 60529 • Maximum output power up to 500/600/700W; Adapted to 60 &72 cells PV panels On Grld AS/NZS 4777.2:2015VDE AR N4105:2011 08DIN V VDE V 0126 1 1/A1:201202 • Peak efficiency 96.7%; CEC weighted efficiency 96.5% IEC61727:2004EN50438:2013ANSI/IEEE 1547.1 IEC62116:2011 UTE C 15-712-1:2010-07 • Static MPPT efficiency 99.8%; Dynamic MPPT efficiency 99.76% in overcast weather NBT32004-2013 • High reliability: NEMA6 (IP67) enclosure; 6000V surge protection eeI; ili C c; ( T G83 c us INMEINO CH I 1®(0 www.chikolancom/ww - - -- Solar Mounting Solutions PRODUCT LINE Item Product Name CK-FTH-21 1 CHIKO AL Roof Hook 211 I TECHNICAL DATA ;; i, Main Material 6005-T5 & SUS304 h' Uplift P N*Fv (N=3) ' Wind Load Up to 60 M/S Snow Load 1 .4 KM/M2 Hook Spacing Up to 2000mm Installation Site Roman Tile Roof AL Roof Hook 019 111- - " .0 CHIKO L Feet matching to the ` i Flashing,supplying the best waterproofing \ 3o5 solution for Asphalt Shingles Roofs. �s `� ADVANTAGES COMPONENT LIST WARRANTY PI Enables simple, fast and cost-effective MATERIAL QTY installation. AL Flashing 01 N 'tTY G`'G t, AL L Feet 01 � - • High class anodized aluminium. -.4 1 0 ,,;- • Fasteners and rail nut configurated to 050 Nut 01 YEARS SUS Bolt M8*25 01 ,, -.4 save extra parts purchasing. SUS M8 Wahser 02 • 100% water proofing. Wooden Screw M8*90 01 Silicon Rubber 01 UI LISTED th. �mORDERING SPECIFICS C US us Standard Packaging 1 6PCS/CTN LISTED Dimensions 34X25X7CM LISTED Intertek [PV MOUNTING SYSTEM 5010190 Weight 6KG E483644 Conforms to UL STD NO.2703 Fax:86-21 -59972938 C 114 ° www.chlkolar.com/www.chikosolancom Solar Mounting Solutions PRODUCT LINE Item Product Name CK-7R-2100 CHIKO 7 RAIL 2100MM CK-7R-3200 CHIKO 7 RAIL 3200MM CK-7R-4200 CHIKO 7 RAIL 4200MM TECHNICAL DATA Main Material AL 6005-T5 Wind Velocity Up to 60 M/S 30.8 Xi=31918.082 mm4 L Yi=81501 .592 mm4 7RAIL Ln CHIKO 7R aluminium rail is designed for o roof mounting system, it could applied on �? CO all roof mount system. f 31.3 ADVANTAGES COMPONENT LIST WARRANTY ■ Easy installation MATERIAL QTY ZTY ■ Highclass anodized Aluminium Rail 01 0) • Tilt- in nut YEARS • Universal on roof mount system UL LISTED ORDERING SPECIFICS Standard Packaging 8 PCS/PKG U Q Dimensions 2100/3200/4200mm C ® L USus Weight 15/22.8/30KG isTE LISTED Intertek [PV MOUNTING SYSTEM 5010190 E483644 Conforms to UL STD NO.2703 Phone.86-21-59972267-861 Fax C 11 I I ( www.ch►kolar,com/www.ch►koso., - r.com Solar Mounting Solutions PRODUCT LINE Item Product Name CK-FT-SKA CHIKO 7 Rail Splice Kit TECHNICAL DATA Main Material AL 6005-T5 Wind Load Up to 60 M/S Snow Load 1 .4 KM/M2 � 7 RAIL SPLICEKIT 20�� 45.7mm CHIKO 7R aluminium rail splice kit is f: 0 designed for 7R rail connection from back to position. The most simple and handy installation way. [21 ADVANTAGES COMPONENT LIST WARRANTY Easy installation MATERIAL QTY l .tY U Highclass anodized Aluminium Rail Splice Kit 01 �� 0 92 SUS304 Bolt M8*25 02 �, R co0sgjRMOUNTING:.,4 Star Washer 02 y: ORDERING SPECIFICS Standard Packaging 200 PCS/PKG ( II. ) Dimensions 51 X38X22CM C US us Weight 30KG osTo LISTED Intertek [PV MOUNTING SYSTEM] 5010190 E483644 Conforms to UL STD NO.2703 Phone:86-21 -59972267-801 Fax:86-21-59972938 0E11 WWW.Ch . Solar Mounting Solutions _.�.__ �- _ ._ ._ _ . --�._- PRODUCT LINE Item Product Name CK-FTM-K30 CHIKO Intergated Grounding Mid Clamp 30mm ® CK-FTM-K33 CHIKO lntergated Grounding Mid Clamp 33mm CK-FTM-K35 CHIKO Intergated Grounding Mid Clamp 35mm CK-FTM-K38 CHIKO lntergated Grounding Mid Clamp 38mm CK-FTM-K40 CHIKO Intergated Grounding Mid Clamp 40mm _, ,4 6 TECHNICAL DATA Main Material AL 6005-T5 Intergated Grounding o Mid Clamp o of, 1 CHIKO end clamps is designed base on 7R rail to fix module on the end of rail, have ` =30/33/35/38/40/45/ `: 4 founction of intergated grounding, 30mm ! �U, to 50 mm thickness module are available. W '` ADVANTAGES COMPONENT LIST WARRANTY Intergated Grounding MATERIAL QTY Easy installation Mid Clamp 01 Pt.\,,ATY 6.0 SUS304 Bolt M8 01 0 1O % ',: — High class anodized YEARS, Tilt- in nut 050 SUS304 Nut 01 o r r,y MouNT,NG. _. Rivet 02 Fill T i ORDERING SPECIFICS U ajo, Standard Packaging 100 PCS/BOX 400PCS/CTN C ® L UsDimensionsuS 50X38X20CM s LISTED Intertek Weight 26.8/27.5/28/28.6KG [PV MOUNTING SYSTEM] 5010190 E483644 Conforms to UL STD NO.2703 C H I I- (b www.chikolar.com/www.chikousaacom Solar Mounting Solutions ._ ... .. PRODUCT LINE Item Product Name CK-FTE-K30 CHIKO Intergated Grounding End Clamp 30mm CK-FTE-K33 CHIKO Intergated Grounding End Clamp 33mm CK-FTE-K35 CHIKO Intergated Grounding End Clamp 35mm CK-FTE-K38 CHIKO Intergated Grounding End Clamp 38mm CK-FTE-K40 CHIKO Intergated Grounding End Clamp 40mm „. TECHNICAL DATA Main Material AL 6005-T5 Intergated Grounding CD End Clamp ®=30.'�''��:�f35�38��;��n'��a5,�', CHIKO end clamps is designed base on1414_ 7R rail to fix module on the end of rail, have founction of intergated grounding, 30mm to 50mm thickness module are available. ADVANTAGES COMPONENT LIST WARRANTY ■ Intergated Grounding MATERIAL QTY S�S7 Y G�j,"`. • Easy installation End Clamp 01 SUS304 Bolt M8*25 011 a High class anodized 4 YEARS Tilt- in nut SUS304 Washer M8 01 _. 050 SUS304 Nut 01 ►r1�� Rivet 01 UL LISTED ORDERING SPECIFICS _ °M Standard Packaging 100 PCS/BOX 400PCS/CTN F, I- US us Dimensions 50X38X20CM CIsr60 LISTED Intertek Weight 22/24.5/25.5/26KG [PV MOUNTING SYSTEM] 5010190 E483644 Conforms to UL STD NO.2703 Phone:86-21. -59972267-801 Fax:86-21-59972938