Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File BLD-2020-0758 4515 Blakely Drive
1 C} City of Anacortes Invoice/Permit#: BLD-2020-0758 904 6th Street • Applied date: 12/04/2020 P.O.Box 547 Issue date: 12/07/2020 _ 0, Anacortes, WA 98221-0547 (360) 293-1901 Expire date: 06/05/2022 Job Address: 4515 BLAKELY DR Permit Type: PV Solar Permit ANACORTES WA 98221-1161 Project: APN: P111877 Remarks: INSTALL A ROOFTOP SOLAR PV SYSTEM, 2 ARRAYS OF 16 PANELS. Owner: STEPHEN &VELDA BROWN Contractor: TML INTERNATIONAL LLC Address: 4515 BLAKELY DR Address: 6405 E MILL PLAIN BLVD ANACORTES WA 98221-1161 VANCOUVER WA 98661 Phone: (360)395-5716 Phone: (775)842-1905 License#: General Information: Fees: Building Valuation 1600 Building Permit Fee 57.05 Plan Review Fee 37.08 State Building Code Fee Resi 6.50 Total Calculated: 100.63 Deposits/Receipts: 0.00 Total Due: 100.63 The issuance or granting of this permit shall not be construed to be a permit for,or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting of this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City,or of any state or federal law,or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or decision of the Governor.This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and examined this application and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY PHOTOVOLTAIC ROOF MOUNT SYSTEM 16 MODULES - SYSTEM SIZE STC (5.44 kW DC / 3.84 kW AC) 00_HO 4515 BLAKELY DR, ANACORTES, WA 98221 , USA (48.49613, -122.66627) ccolEEK 10HL000 SAFETY PLANS LOCATION OF NEAREST URGENT CARE FACILITY SHEET INDEX GREEN THINK ENERGY LLC SYSTEM SUMMARY STC DC/AC NOTES: NAME: PV-1 SITE PLAN&SAFETY PLAN 50 HARRISON STREET, (5.44 kW DC / 3.84 kW AC) PV-2 ROOF PLAN WITH MODULES SUITE 202B INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME. ADDRESS: CITY OF ANACORTES PV-3 ATTACHMENT DETAIL HOBOKEN,NJ 07030 • INSTALLERS SHALL UPDATE NAME,ADDRESS AND PHONE NUMBER OF • 2x STRINGS OF 8 CONNECTED IN PARALLEL PHONE NUMBER: PV-4 SINGLE LINE DIAGRAM www.GreenThinkEnergy.com NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE PLANNING AND BUILDING D E PT: PV-5 THREE LINE DIAGRAM -(16) Hanwha Q.Peak Duo-G6 340 MODULES STARTING WORK. CONTRACTOR -(16) Enphase IQ7-60-2-US MICROINVERTERS PV- CALCULATION APPROVED PLANS PV-7NAME:N/A PLACARDS LARDS STC DC: (16)340 = 5.44 kW PV-8+ EQUIPMENT SPECIFICATION ADDRESS:N/A STC AC: (16)240 = 3.84 kW REVIEWED FOR CODE COMPLIANCE PHONE#:N/A PERMIT#: BLD-2020-0758 LICENSE it N/A GOVERNING CODES ADDRESS: 4515 Blak ly DR REVISIONS 2015 INTERNATIONAL BUILDING CODE APPROVED BY: �"'�S V �J • PROJECT ID: N/A DESCRIPTION DATE REV 2015 INTERNATIONAL ENERGY CONSERVATION CODE al SUBJECT TO FIELD INSPECTION.APPROVED PL S SHALL NOT AHJ: SKAGIT 2015 INTERNATIONAL FIRE CODE rr ---- - - --- BE ALTERED WITHOUT AUTHORIZA ON. (f ' 2015 INTERNATIONAL RESIDENTIAL CODE D �- 87r_Grr 6'-, „ . _ _J ARRAY LOCATION - SIGNATURE&SEAL i _ _ ►.� � / PROP —< I LINE v I " - Ci / B'-2" 75,?, . .. i Zi r N...4. •_, . . c0 '^ii_______ • _< CJ I •I j �,1•0/ PROJECT NAME - � � co • GENERAL NOTES: z i D • ALL PANELS,SWITCHES,ETC.SHALL HAVE SUFFICIENT GUTTER / -- . ��r 4, z SPACE AND LUGS IN COMPLIANCE TO UL REQUIREMENTS TO i ;� Q N ACCOMMODATE CONDUCTORS SHOWN. ai, • THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL W ,^ co FROM THE LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. 71-711 Pir �' v J HOUSE PHOTO 0 J 0., • ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT Q_ ii I INCLUDING THOSE THAT ARE EXPOSED TO OUTSIDE a SCALE: NTS Ct LLI < ENVIRONMENT SHALL BE WEATHERPROOF AND SHALL BE PROP _ .� m SHALLLISTED BY'UL"FOR THE TYPE OF APPEAR ON ALL ELECTRICAL EQUIPMENT.AND"UL"LABEL ERTY LINES _ ' W Q • WIRING METHOD SHALL BE EMT ABOVE GROUND MOUNTED IN _ m LLI CONCEALED SPACES(UNLESS APPROVED OTHERWISE)AND 871�5,- •I - > in I- I- SCHEDULE-40 PVC FOR BELOW GROUND INSTALLATIONLLI v UNLESS NOTED OTHERWISE. PROJECT SITE In • AN OSHA APPROVED LADDER PROVIDING ACCESS TO ALL �� =� H O PORTIONS OF THE ARRAY SHALL BE SECURED IN PRIOR TO 7-2 Cr)REQUESTING INSPECTION. "1/4 "' Q • IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A z SUPPLEMENTAL GROUNDING ELECTRODE CONDUCTOR IF Q NECESSARY. [. MSP MAIN SERVICE PANEL AC AC DISCONNECT I NV (0)INVERTER SUB SUB-PANEL EE EEQUIPMNG ENT ROOF ATTACHMENT ---------- PROPERTY LINE r 4515 Blakely Cum SHEET NAME NEW(200A) UNFUSED NEW N/A N/A m LOAD CENTER SITE PLAN & UM UTILITY METER ACF AC DISCONNECT LC (COMBINER PANEL) DCD DC DISCONNECT • OPTIMIZER - // -DIMENSIONS FENCE m NEW FUSED N/A _ NEW N/A z SAFETY PLAN PRODUCTION METER JUNCTION BOX SOLAREDGE METER DCC COMBINER MICRO-INVERTER PV MODULE GATE PM N/A JB NEW SM N/A DCC N/A0 SHEET SIZE ANSI B BAT BATTERY AT AUTO TRANSFORMER BLP BACKUP LOAD PANEL 11" X 17" _ N/A N/A N/A 3 VICINITY MAP SHEET NUMBER SITE PLAN & SAFETY PLAN PV 1 SCALE: 1/16" = 1'-0" MODULE AREA &WEIGHT CALCULATIONS • PANEL TYPES(COUNT,AREA,WEIGHT):•(16x)Hanwha Q.Peak Duo-G6 340(68.5"x 40.55",43.9 LBS) COTEK ATTACHMENT COUNT:45 �M MOUNTING SYSTEM WEIGHT/MODULE:1.5 LBS u u _HE TOTAL ROOF AREA: 1992 SF � LE n n�����7 TOTAL ARRAY AREA:(16)68.5"x 40.6"=308.63 SF L^\u� Un 1J \'rV/ TOTAL ARRAY WEIGHT:(16)43.9+(16)1.5=726 LBS \\\\N ` `, A CD J U LJ I',7\` GREEN THINK ENERGY LLC WEIGHT AT EACH CONNECTION:726 LBS/45=16.14 LBS �� 50 HARRISON STREET, DISTRIBUTED LOAD:726 LBS/308.63 SF=2.35 PSF *wee \\\\\\\\ ` L CD SUITE 202B ROOF AREA COVERED BY ARRAY:309 SF/1992 SF=15.5% \ !,1:144h HOBOKEN,NJ 07030 BILL OF MATERIALS k` � i`__\,� , `\ www.GreenThinkEnergy.com SOLAR PV MODULES 16 Hanwha Q.Peak Duo-G6 340 '""� -_ -_`i_i �►`\! CONTRACTOR MICRO INVERTERS 16 Enphase IQ7-60-2-US U U _ ____ NAME:N/A LOAD CENTER 01 AC COMBINER PANEL(MIN RATING 20A) Q Q ___ _ ___ —_ ADDRESS:N/A AC DISCONNECT 01 PV VISIBLE LOCKABLE I-- m LU ____ ____ __ PHONE#:N/A LABELED DISCONNECT _ _ __ —_ __ LICENSE#:N/A (30A UNFUSED 1PH 240VAC) 'I 0 — ——__— — _ REVISIONS Li CCATTACHMENTS 45 IronRidge-FlashFoot2 ' _ __ —_RAIL - IronRidge-XR10 7 _- -___ -___ - - DESCRIPTION DATE REV )>, t SIGNATURE&SEAL pil ‘... ,... ,.., ,...,,, or Nk tir- -- = if l «i 'Ililir •Ia a1iE, LLc-Ito PROJECT NAME a117' _ io ir z aol :' . -=Ili) at 1::: v:" lir CV CO 18" access permitted - � i` � �;�'�l � II! _ w under 605.11.12 '-1 II i '- II \i� . _ --_ _ Q 1 6 0111 _ — m Q exception #5 __ J rn 3'-4►' - ---_ - I CO w N - O I W LO LO fl I- 6 -1y E o II Cl) U 2'-2 II z ROOF DESCRIPTION I Q MAIN SERVICE PANEL AC INV ( )INVERTER SUB AC DISCONNECT 0 ERT EXISTING • ROOF ATTACHMENT RAFTERS ROOF ARRAY AZIMUTH RAFTERS RAFTERS SPACING MSP NEW(200A) UNFUSED NEW N/A SUB-PANEL EE EQUIPMENT r TILT SIZE (ATTACHMENT SPACING) m^ I SHEET NAME I LOAD CENTER U J #1 20° 100° 2"X4" 12"O.C. (48") UTILITY METER ACF AC DISCONNECT LC (COMBINER PANEL) DCD DC DISCONNECT • OPTIMIZER — // —DIMENSIONS ROOF RAILS m ROOF PLAN WITH 20° 280° 2"X4" 12"o.c. (48") NEWZ #2 _ FUSED N/A NEW N/A _ MODULES Pm PRODUCTION METER J g JUNCTION BOX S M SOLARED N/AI N/A EMETER D C C DC COMBINER MICRO-INVERTER PV MODULE 1 7 77 FIRE SETBACK SHEET SIZE BAT BATTERY AT AUTO TRANSFORMER gLp BACKUP LOAD PANEL ANSI B N/A N/A N/A Ariv. 11" X 17" ROOF PLAN WITH MODULESSHEET NUMBER SCALE: 1/8" = 1'-0" PV-2 \,c_, 171H_HE c IFE117 PV MODULE ,--� GREEN THINK ENERGY LLC 50 HARRISON STREET, SUITE 202B SEE (2/PV-4) FOR HOBOKEN,NJ 07030 ENLARGED VIEW www.GreenThinkEnergy.com :TRACTOR NAME:N/ ADDRES PHONE#: �' (E SINGLE LAYER OF LICENSE COMPOSITE SHINGLE REVISIONS DESCRIPTION DATE REV RAFTERS JOSIGNATURE&SEAL ATTACHMENT DETAIL SCALE: NTS PROJECT NAME Q PV MODULES D IRONRIDGE INTEGRATED Z GROUNDING & END/MID 0 N CLAMP 0 2 IRONRIDGE XR10 RAIL Et W < m w J � (E) SINGLE LAYER OFm W 0.0.014 COMPOSITE SHINGLE > inrl � � O Q 1 Q ALUMN. "L" BRACKET = FLASHING W/3/8" SS BOLT & NUT ' -_ SHEET NAME ATTACHMENT IRONRIDGE FLASH -I DETAIL FOOT2 ATTACHMENTS 5/16"x3.5" SS LAG BOLT 11 WITH MIN 2%2" THREAD 'Fittl JILL ■1111W EMBEDMENT, SEALED ANSI B PENETRATION 11" X 17" 2 ATTACHMENT DETAIL (ENLARGED SECTION VIEW) SHPVU3ER SCALE: NTS RAFTERS SYSTEM SUMMARY STC DC/AC NOTE: NOTE: • ALL GROUNDING TO COMPLY WITH NEC 690.47. GROUNDING ELECTRODE CONDUCTOR/SYSTEM ) (5.44 kW DC / 3.84 kW AC) • ROOF TOP CONDUIT SHALL BE LOCATED MIN.7/8" BONDING JUMPER NOT REQUIRED FOR SOLAREDGE OMMMM • 2x STRINGS OF 8 CONNECTED IN PARALLEL ABOVE ROOF SURFACE. POWER OPTIMIZER.PROPERLY INSTALLED SYSTEM • ALL TERMINALS SHALL BE MIN.90 DEG.C RATED. MEETS THE REQUIREMENTS OF NEC 690.35 FOR 'MAE -(16)Hanwha Q.Peak Duo-G6 340 MODULES UNGROUNDED PV POWER SYSTEMS.PROVIDE u u -(16)Enphase IQ7-60-2-US MICROINVERTERS EQUIPMENT GROUNDING PER MANUFACTURER'S �lJ�J�J U� lJ STC DC: (16)340=5.44 kW REQUIREMENTS IN COMPLIANCE WITH THE NEC. IIL���I�f\\"lulllll���JnUU11 \'rv/ STC AC: (16)240=3.84 kW o LJ GREEN THINK ENERGY LLC 50 HARRISON STREET, SUITE 202B HOBOKEN,NJ 07030 www.GreenThinkEnergy.com CONTRACTOR NAMEMAIN SERVICE PANEL N/A MOD: Hanwha Q.Peak Duo-G6 340 ADDRESS: N/A INV: Enphase IQ7-60-2-US (240V) (NEW, TOP-FED) PHONE UTILITY METER PI NE#:N/A it/A (1 STRING X 8 MICRO-INV) BUS RATING: 200A MAIN BREAKER: 200A(N) UTILITY: A PSE REVISIONS SERVICE: 240V 60HZ 1 PH DESCRIPTION DATE REV 1 2 ° ° 8 PV VISIBLE LOCKABLE 200A TO JUNCTION BOX _,/_ 600V, NEMA 3R AC COMBINER PANEL LABELED DISCONNECT 411) — UTILITY WITH ENPHASE ENVOY (30A UNFUSED 1PH 240VAC) GRID Vry MS-01 UL LISTED XAM1-120 (OR EQUIV) �— SIGNATURE&SEAL MCB-01 EE 10A I LC 01 r, .y, LC-01 F �� MOD: Hanwha Q.Peak Duo-G6 340 MCB-01 INV: Enphase IQ7-60-2-US (240V) 15A (1 STRING X 8 MICRO-INV) 1 A 5 ON OFF v _ 1 2 ° ° 8 20A —n— I PROJECT NAME 1 V MS-01 _L Q G7 D z r: 0 N O ›- SS O� Et LLI < m Q w U W in I— W - AC wire details I--��/� 0 Wire Min Ampacity Live Neutral Ground Min EMT Min PVC Min RMC vJ Q MS-01 10.00A (2) 10 AWG PV 10 AWG PV 10 AWG THWN-2 0.75 in 0.75 in 0.75 in z MCB-01 10.00A (2) 10 AWG THWN-2 10 AWG THWN-2 10 AWG THWN-2 0.50 in 0.50 in 0.50 in Q LC-01 20.00A (2) 10 AWG THWN-2 10 AWG THWN-2 10 AWG THWN-2 0.50 in 0.50 in 0.50 in INTERCONNECTION SHEET NAME 120% RULE (MAIN PANEL) EXTREME CASE MODULE OUTPUT SINGLE LINE Hanwha Q.Peak Duo-G6 340 UTILITY FEED +TOTAL BACKFEED DIAGRAM 200A+20A=220A Isc(25°C)= 10.68A,Tisc=0.040%/°C Isc(T)= Isc(25°C)x[1 +Tisc x(T-25°C)] LESS OR EQUAL TO Isc(0°C)= 10.57A, Isc(40°C)= 10.74A SHEET SIZE BUS RATING X 120% ANSI B 200A x 120%=240A Voc(25°C)=40.24V,Tvoc=-0.280%/°C 11" X 17" ELECTRICAL SINGLE LINE DIAGRAM Vooc(0c(T)C)Voc(25°6V,C)x Voc(40°C)Tvoc (T-25°C)]38. CALCULATION ENSURES BUS IS Voc(0°C)=43.06V, =38.55V SHEET NUMBER SCALE: NTS SAFE REGARDLESS OF LOADS PV-4 LYSTEM SUMMARY STC DC/AC NOTE: NOTE: • ALL GROUNDING TO COMPLY WITH NEC 690.47. GROUNDING ELECTRODE CONDUCTOR/SYSTEM .44 kW DC / 3.84 kW AC) • ROOF TOP CONDUIT SHALL BE LOCATED MIN.7/8" BONDING JUMPER NOT REQUIRED FOR SOLAREDGEx STRINGS OF 8 CONNECTED IN PARALLEL ABOVE ROOF SURFACE. POWER OPTIMIZER.PROPERLY INSTALLED SYSTEM16)Hanwha Q.Peak Duo-G6 340 MODULES • ALL TERMINALS SHALL BE MIN.90 DEG.C RATED. MEETS THE REQUIREMENTS OF NEC 690.35 FOR16)Enphase IQ7-60-2-US MICROINVERTERSUNGROUNDED PV POWER SYSTEMS.PROVIDEC DC: 16 340=5.44 kW EQUIPMENT GROUNDING PER MANUFACTURER'S( ) REQUIREMENTS IN COMPLIANCE WITH THE NEC.0 AC: (16)240=3.84 kW GREEN THINK ENERGY LLC 50 HARRISON STREET, SUITE 202B HOBOKEN,NJ 07030 www.GreenThinkEnergy.com CONTRACTOR MOD: Hanwha Q.Peak Duo-G6 340 MAIN SERVICE PANEL NAME:N/A INV: Enphase IQ7-60-2-US (240V) ADDRESS:N/A (NEW, TOP-FED)(1 STRING X 8 MICRO-INV) BUS RATING: 200A UTILITY METER PHONE#:N/A LICENSE#:N/A MAIN BREAKER: 200A(N) UTILITY: PSE SERVICE: 240V 60HZ 1 PH REVISIONS 1 2 O O 8 DESCRIPTION DATE REV PV VISIBLE LOCKABLE 200A TO JUNCTION BOX �— MS-01 600V, NEMA 3R AC COMBINER PANEL LABELED DISCONNECT — CI E-- UTILITY UL LISTED WITH ENPHASE ENVOY (30A UNFUSED 1 PH 240VAC) �� GRID XAM1-120 (OR EQUIV) —` SIGNATURE&SEAL MCB-01 EE 10A LC-01 I ElLC-01 _� B MOD: Hanwha Q.Peak Duo-G6 340 MCB-01 INV: Enphase IQ7-60-2-US (240V) 8 15A (1 STRING X 8 MICRO-INV) -C--4- la 15A ON OFF v 1 2 0 0 8 20A 00tt MS-01 PROJECT NAME D Z E N O >- ss d� _, D W < m Q w Uw LU F-- W - AC wire details L 0 Wire Min Ampacity Live Neutral Ground Min EMT— Min PVC Min RMC (] 0 MS-01 10.00A (2) 10 AWG PV 10 AWG PV 10 AWG THWN-2 0.75 in 0.75 in 0.75 in Z MCB-01 10.00A (2) 10 AWG THWN-2 10 AWG THWN-2 10 AWG THWN-2 0.50 in 0.50 in 0.50 in Q LC-01 20.00A (2) 10 AWG THWN-2 10 AWG THWN-2 10 AWG THWN-2 0.50 in 0.50 in 0.50 in INTERCONNECTION SHEET NAME 120% RULE (MAIN PANEL) EXTREME CASE MODULE OUTPUT Hanwha Q.Peak Duo-G6 340 THREE LINE UTILITY FEED+TOTAL BACKFEED DIAGRAM Isc(25°C)= 10.68A,Tisc=0.040%/°C 200A+20A=220A Isc(T)= Isc(25°C)x[1 +Tisc x(T-25°C)] LESS OR EQUAL TO Isc(0°C)= 10.57A, Isc(40°C)= 10.74A SHEET SIZE BUS RATING X 120% ANSI B 200A x 120%=240A Voc(25°C)=40.24V,Tvoc=-0.280%/°C 11" X 17" Voc(T)=Voc(25°C)x[1 +Tvoc x(T-25°C)] ELECTRICAL THREE LINE DIAGRAM CALCULATION ENSURES BUS IS _Voc(0°C)=43.06V,Voc(40°C)=38.55V SHEET NUMBER SCALE: NTS SAFE REGARDLESS OF LOADS PV-5 SYSTEM SUMMARY (5.44 kW DC / 3.84 kW AC DC/AC 7 � 1EL� • 2x STRINGS OF 8 CONNECTED IN PARALLEL \ \ IM HE - (16) Hanwha Q.Peak Duo-G6 340 MODULES > IJ LJ - (16) Enphase IQ7-60-2-US MICROINVERTERS Cill EHE M STC DC: (16) 340 = 5.44 kW �( STC AC: (16) 240 = 3.84 kW GREEN THINK ENERGY LLC 50 HARRISON STREET, SUITE 202B HOBOKEN,NJ 07030 www.GreenThinkEnergy.com CONTRACTOR NAME:N/A ADDRESS:N/A PHONE#:N/A LICENSE#:N/A REVISIONS DESCRIPTION DATE REV SIGNATURE&SEAL AC wire details Nominal Backfeed*1.25 Min Total Conductor ccConductors Expected Temp Conduit fill Conductor& EGC size Conductor Max Min EMT Min PVC Min RMC WirelD #Modules Voltage /cond. set OCPD Power sets /conduit max temp derate derate neutral size (Cu) metal Insulation length V drop size size size MS-01 8 240 V 10.00 A 15 A 1.9 kW 1 2 40 0.91 1.00 10 AWG 10 AWG Cu PV 50 ft 0.35% 0.75 in 0.75 in 0.75 in MCB-01 8 240 V 10.00 A 15 A 1.9 kW 1 2 40 0.91 1.00 10 AWG 10 AWG Cu THWN-2 50 ft 0.35% 0.50 in 0.50 in 0.50 in LC-01 16 240 V 20.00 A 20 A 3.8 kW 1 2 40 0.91 1.00 10 AWG 10 AWG Cu . THWN-2 10 ft 0.14% 0.50 in 0.50 in 0.50 in PROJECT NAME Q INTERCONNECTION C/) 120% RULE (MAIN PANEL) EXTREME CASE MODULE OUTPUT Z D Hanwha Q.Peak Duo-G6 340 UTILITY FEED +TOTAL BACKFEED N 200A+20A=220A Isc(25°C)= 10.68A, Tisc=0.040%/°C i� N Isc(T)= Isc(25°C)x[1 +Tisc x(T-25°C)] CO LESS OR EQUAL TO Isc(0°C)= 10.57A, Isc(40°C)= 10.74A O J 6) BUS RATING X 120% ► Et W Q 200A x 120%=240A Voc(25°C)=40.24V,Tvoc=-0.280%/°C m Q Voc(T)=Voc(25°C)x[1 +Tvoc x(T-25°C)] CALCULATION ENSURES BUS IS Voc(0°C)=43.06V,Voc(40°C)=38.55V in J c SAFE REGARDLESS OF LOADS \ CIOin ELECTRICAL NOTES in LLI In o 1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. I 0 2) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. /) Q 3) WIRING, CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO,AND z LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. Q 4) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND SHEET NAME STANDARDS. WIRING 6) WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED,THE CALCULATION CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT SHEET SIZE RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. ANSI B 9) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO 11" X 17" GBL-4DBT LAY-IN LUG. 10) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NEC 690. SHEET NUMBER 11) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF INSTALL. `, 12) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER NEC 310.15(B)(16). P V-6 A�� QWARN I NG 0EEEK CAUTIONA CAUTION A PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC SYSTEM DUAL POWER SOURCE SECOND UH_HE CIRCUIT IS BACKFED COMBINER PANEL SCORCE IS PHOTOVOLTIC CI ���J Uow LABEL LOCATION:BACKFED BREAKER DO NOT ADD LOADS LABEL LOCATION:SERVICE METER �u CODE REF:NEC 705.2(4) MAIN PANEL CODE REF:UTILITY GREEN THINK ENERGY LLC 50 HARRISON STREET, LABEL LOCATION:AC COMBINER PANEL CODE REF: NEC 690.12(B) HOBOKEN SUITE 202B ,NJ 07030 NAME: A WARN I N G QWARN I N G www.Gr SUIT ergy.com CONTRACTOR 2 INVERTER OUTPUT CONNECTI 0 14 INVERTER OUTPUT ADDRESS:N/A DO NOT RELOCATE THI CONNECTION PHONE#:N/A LICENSE#:N/A VERCURRENT DEVIC ) DO NOT RELOACATE THIS REVISIONS LABEL LOCATION: BACKFED BREAKER OVERCURRENT DEVICE DESCRIPTION DATE REV CODE REF:2017 NEC 705.12(2)(3)(b) WARNING LABEL LOCATION: IF APPLICABLE SERVICE PANEL ArA ATION SCOURGE IS CONNECTED TO THE SUPPLY(UTILITY) 3 QWARNING CODE REF:NEC 705.12(D)(7) SIDE OF THE MAIN SERVICE DISCONNECT.FOLLOW THE PROPER ALOCK-OUT/TAG-OUT PROCEDURES TO ENSURE THE PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH IS OPENED PRIOR TO ELECTRICAL SHOCK HAZARD PERFORMING WORK ON THIS DEVICE TERMINALS ON BOTH LINE AND LOAD SIDES LABEL LOCATION:(IF APPLICABLE)SUPPLY SIDE TAP THE OPEN POSITIONIZED IN DCVOLTAGEISALWAYSPRESENT APHOTOVOLTAIC SYSTEM LOAD PANELUTILITY DISCONNECT SWITCH CODE REF:UTILITY WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION:AC DISCONNECT SIGNATURE&SEAL LABEL LOCATION: DC DISCONNECT,COMBINE BOX CODE REF:UTILITY PHOTOVOLTAIC AC DISCONNECT CODE REF:NEC 690.13(B) PROJECT NAME A RATED AC OPERATING CURRENT: 16_AMPS NOMINAL OPERATING AC VOLTAGE: 240 VAC Mr àWA R N I N G I LABEL LOCATION:MAIN PANEL AC DISCONNECT(S) ALSOLARPVSYSTEM EQUIPPED ELECTRICAL SHOCK HAZARD D CODE REF:NEC 690.54 IF GROUND FAULT IS INDICATEDEt WITH RAPID SHUTDOWN ALL NORMALLY GROUNDED 0 N CONDUCTORS MAY BE 0 SHUTDOWN SWITCH UNGROUNDEDAND ENERGIZED / YAIAPID MM FOR SOLAR PV SYSTEM LABEL LOCATION:AC DISCONNECT W Q TURN RAPID SHUTDOWN COMBINER BOX SERVICE PANEL IJJ _1COSWITCH TO THE "OFF" SOLAR ELECTRIC CODE REF:NEC 690.5(C) CO in PV PANELS > LABEL LOCATION:MAIN PANEL POSITION TO SHUTDOWN CODE REF:NEC 690.12 PV SYSTEM AND REDUCE w j fl III Aal A SHOCK HAZARD IN THE PV SOLAR BREAKER ARRAY. WARNING DO NOT RELOCATE THIS z ELECTRICAL SHOCK HAZARD OVERCURRENT DEVICE Q TERMINALS ON BOTH LINE AND • • LOAD SIDES MAY BE ENERGIZED LABEL LOCATION:MAIN SERVICE LABEL LOCATION: MAIN PANEL SHEET NAME IN THE OPEN POSITION CODE REF: NEC 690.12 DEAD FRONT NEC 690.56(C)(1)(A) CODE REF:NEC 705.12(B)(2)(3)(B) PLACARDS LABEL LOCATION:COMBINER PANEL AC DISCONNECT 12 LOCATION: DC CONDUIT JUNCTION JUNCTION BOX INVERTER(S) WARNING PHOTOVOLTAIC POWER SOUR CO MORE THEN 10FT CODE REF:NEC 690.13(b) CODE REF:NEC 690.31(G)(3) SHEET SIZE NEC 690.31(G)(4) ANSI B A0T°v° b0 11" x 17" SYSTEM METER REFLECTIVE AND WEATHER RESISTANT LABEL REQUIRES CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF 3/8 INCH,WHITE LETTERS ON RED BACKGROUND LABELS SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, SHEET NUMBER LABEL LOCATION: DEDICATED KWH METER RACEWAYS,ENCLOSURES,AND CABLE ASSEMBLIES EVERY 10FEET,WITHIN 1 FOOT OF TURNS ON BENDS AND PV-7 CODE REF:NEC 690.4(B)UTILITY WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS OF BARRIERS. coEEEK I 1 1 IIIH_HE , 1 -powered by MECHANICAL SPECIFICATION - Q.ANTUM /DUO/ Format 1740mm x 1030mm x 32mm(including frame) 17.10ntm GREEN THINK ENERGY LLC Weight 19.9kg I-"°mm •I "°'° • 50 HARRISON STREET, Front Cover 3.2mm thermally pre-stressed glass with Ic ; SUITE 202B anti-reflection technology �� HOBSUITEOKEN,NJ 07030 Back Cover Composite film www.GreenThinkEnergy.com Frame Black anodised aluminium Cell 6 x 20 monocrystalline Q.ANTUM solar half cells ® mw.., CONTRACTOR Junction boo 61-71mm x 41-50mm x 13-21mm ,,,,,� NAME N/A Protection class IP67,with bypass diodes xuso Cable 4mm2 Solar cable;(+)1150mm,(-)1150mm • ('�° � oM ADDRESS:N/A 1 Connector Multi-Contact MC4,IP68 L r a1 wu ..w0 a I • PHONE#:N/A 1 -I l-az- SmI�I85mm LICENSE#:N/A \ \ P \ REVISIONS 1 11 `4 .. ELECTRICAL CHARACTERISTICSPOWER CLASS as DESCRIPTION DATE REV P A D O ' e\:' \\I 114 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+Syy33 OW) 335 340 345 t1 Power at MPP' P [W] 330 335 340 345 1 �1 1 1 \ Short Circuit Current' I. [A] 10.57 10.62 10.68 10.73 Q.ANTUM SOLAR MODULE E Op en Circuit Voltage' V. [V] 39.74 39.99 40.24 40.49 Current at MPP Ix„ (Al 10.06 10.11 10.16 10.22 SIGNATURE&SEAL Voltage at MPP VM„ [V] 32.81 33.13 33.45 33.76 Efficiency' n [%] z18.4 z18.7 z19.0 019.3 The new D PEAK DUO G6 solar module from Q CELLS impresses thanks '■----- MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' to innovative Q.ANTUM DUO Technology, which enables particularly 111111111111.11111111111m Power at MPP Pu,, (W] 246.5 250.2 254.0 257.7 high performance on a small surface.Q.ANTUM's world-record-holding 1������ E Short Circuit Current Iu [A] 8.52 8.56 8.60 8.65 1��--- a Open Circuit Voltage V. [V] 37.39 37.63 37.87 38.10 1111 cell concept has now been combined with state-of-the-art circuitry u■10�f•�� MINENIIIIIIIIIIIIIIIN f Current at MPP Ia„ [A] 7.92 7.96 8.00 8.04 half cells and a six-busbar design,thus achieving outstanding perfor- II■EN1=®1•11111 Voltage at MPP Vu,, [V] 31.14 31.45 31.75 32.04 maneeunderrealeonditions-bothwithlowintensitysolarradiation MEMININIMIIMIIMI 'Measurement tolerances P.,,x3%;Ix,Vo,05%at STC:1000W/m',25x2°C,AM1.5G according to IEC 60904-3•=800W/m',NMOT,spectrum AM1.5G as well as on hot, clear summer days. M■MM=IMMI Y ■■----- OCELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE ■•_--_- PROJECT NAME At least 98%of nominal power during r T ■■----- :S m first year.Thereafter max.0.54% 10 ■��---- ® degradation per year.At least 93.1%of Q.ANTUM TECHNOLOGY:LOW LEVELISED COST OF ELECTRICITY ����-- nominal power up to 10 years.At least Q 1.. ■ 85%of nominal power up to 25 years. Higher yield per surface area,lower BOS costs,higher power I♦��l♦��� /___ classes,and an efficiency rate of up to 19.5%. ��--��� All data within measurement tolerances. ��==--- Full warranties in accordance with the ' .' warranty terms of the Q CELLS sales organisation of your respective country. Z Q INNOVATIVE ALL-WEATHER TECHNOLOGY �1�-=== m r� Z IRRADIANCE WWI Ct Optimal yields,whatever the weather with excellent low-light 1111.11111.11111111- . a Typical module performance under low irradiance conditions in N and temperature behaviour. ,orn,,,,,,,,,0,,,„„„ ,oao,„,,,„„, oo:o 'um comparison to STC conditions(25°C,1000W/m2). a N TEMPERATURE COEFFICIENTS 16 \_ CO CO �J ENDURING HIGH PERFORMANCE ,.CELLS Temperature Coefficient of Isc a [%/K] +0.04 Temperature Coefficient of V°° R [%/K] -0.28 0 IJ LF1W7 Long-term yield security with Anti LID Technology,Anti PID EUPD Temperature Coefficient of Px„ y [%/K] -0.37 Normal Module Operating Temperature NMOT 1°C] 43+3 � (Et -I Technology',Hot-Spot Protect and Traceable Quality Tra.QT"". TOP tIaANovv ,,(Aom no E MUG CO ‘1.2,a EE ✓,°.,° r PROPERTIES FOR SYSTEM DESIGN,ssx Mazimum System Voltage V,., [V] 1000 Safety Class II EXTREME WEATHER RATING 2018 ✓ w L1J J u) High-tech aluminium alloy frame,certified for ✓ U° m,°,a, Maximum Reverse Current Is [A] 20 Fire Rating C CO high snow(5400 Pa)and wind loads(4000 Pa). Max.Design Load,Push/Pull [Pa] 3600/2667 Permitted Module Temperature -40°C up to+85°C \ W V C in 1- Man.Test Load,Push/Pull [Pa] 5400/4000 on Continuous Duty /� O A RELIABLE INVESTMENT G QUALIFICATIONS AND CERTIFICATES PARTNER Inclusive 12-year product warranty and 25-year linear Quality Tested •h H 7 VDE Quality Tested,IEC 61215:2016;IEC 61730:2016,Application class A '" / 1 performance warranty2. _/J This data sheet complies with DIN EN 50380. LJ Q STATE OF THE ART MODULE TECHNOLOGY iD:aoo3zsai ® z Q.ANTUM DUO combines cutting edge cell separation DVE E ttttttttttt� and innovative wiring with Q.ANTUM Technology. ' APT test conditions according - toIEC/TS 62804-1:2015, method B(-1500V,168h) 2 See data sheet on rear NOTE:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation for further information. and use of this product. SHEET NAME il THE IDEAL SOLUTION FOR: cc� Rooftop arrays on Rooftop arrays on Naawha I CELLS GmbH - EQUIPMENT Of. residential buildings ^T commercial/industrial Sonnenallee 17-21,06766 Bitterfeld-Wolfen,Germany I TEL+49(0)3494 66 99-23444 I FAX+49(0)3494 66 99-23000 1 EMAIL sales@q-cells.com I WEB www.q-cells.com H SPECIFICATION �1� buildings Engineered in Germany L CE LLS Engineered in Germany Cat CELLS SHEET SIZE ANSI B 11" X17" SHEET NUMBER PV-8 _, . . . C 1 I I°41 EHE1 DE-\Idln[g Data Sheet Enphase IQ 7 and IQ 7+ Microinverters Enphase Microinverters GREEN THINK ENERGY LLC INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Region:AMERICAS 50 HARRISON STREET, Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ SUITE 202B Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules HOBOKEN,NJ 07030 Maximum input DC voltage 48 V 60 V www.GreenThinkEnergy.com Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V CONTRACTOR Min/Max start voltage 22 V/48 V 22 V/60 V NAME:N/A Max DC short circuit current(module Isc) 15 A 15 A ADDRESS:N/A Overvoltage class DC port II II Enphase The high-powered smart grid-ready PHONE#:N/A pEnphase IQ 7 Micro'and Enphase IQ 7+Micro'° DC port backfeed current o A o A LICENSE#:N/A IQ 7 and IQ 7+ PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; dramatically simplify the installation process while AC side protection requires max 20A per branch circuit REVISIONS achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter DESCRIPTION DATE REV M icroi nverters Part of the Enphase IQ System,the IQ 7 and Peak output power 250 VA 295 VA p y Maximum continuous output power 240 VA 290 VA IQ 7+Microinverters integrate with the Enphase Nominal(L-L)voltage/range° 240 V/ 208 V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V IQ Envoy'°,Enphase IQ Battery",and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Enlighten'monitoring and analysis software. Nominal frequency 60 Hz 60 Hz SIGNATURE&SEAL Extended frequency range 47-68 Hz 47-68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms standards set forth by previous generations and Maximum units per 20 A(L-L)branch circuit° 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) Overvoltage class AC port III III undergo over a million hours of power-on testing, AC port backfeed current 0 A 0 A enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 Warranty of up to 25 years. Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% PROJECT NAME MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) (n Easy to Install Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(IMC4 intermateable). I • Lightweight and simple Adaptors for modules with MC4 or UTX connectors: 7 - • Faster installation with improved,lighter two wire cabling -PV2 to MC4:order ECA-S20-S22 ` PV2 to UTX:order ECA-S20 S25 (V • Built-in rapid shutdown compliant(NEC 2014&2017) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) 0 (\I Weight 1.08 kg(2.38 Ibs) 0 \_ CO II. Productive and Reliable Cooling Natural convection-No fans Approved for wet locations Yes IY UJ•J < • Optimized for high powered 60-cell and 72-cell*modules Pollution degree PD3 CO • More than a million hours of testing Enclosure Class II double-insulated,corrosion resistant polymeric enclosure O �. _ • Class II double-insulated enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor w J (n - • UL listed FEATURES COuJ \ Communication Power Line Communication(PLC) / in H /ENPHASE yl� - Monitoring Enlighten Manager and MyEnlighten monitoring options. w ,QL- --- Smart Grid Ready Both options require installation of an Enphase IQ Envoy. F O F (_: Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break , E, • Complies with advanced grid support,voltage and disconnect required by NEC 690. �/'� 0 frequency ride-through requirements �+ Q 1 ®m OO as -�e5 I P Compliance CA Rule 21(UL 1741-SA) • Remotely updates to respond to changing UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, Z grid requirements CAN/CSA-C22.2 NO.107.1-01 Q This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and • Configurable for varying grid profiles NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC • Meets CA Rule 21(UL 1741-SA) and DC conductors,when installed according manufacturer's instructions. 11 *The IQ 7+Micro is required to support 72-cell modules. SHEET NAME 1.No enforced DC/AC ratio.See the compatibility calculator at httos://enphase.com/en-us/su000rt/module-comoatibility. 2.Nominal voltage range can be extended beyond nominal if required byy the utility. EQUIPMENT CERTIFIED 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. SPECIFICATION EN PHASE To learn more about Enphase offerings,visit enphase.com E N P H AS E. (o learn more about Enphase offerings,visit enphase.com %./ ‘../ ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-05-24 SHEET SIZE ANSI B 11" X17" SHEET NUMBER PV-9 .IIIIIIIIIIRa IRE C Datasheet Datasheet 6 IRONRIDGE Flush Mount System XR Rails e - ( a r [\7 XR10 Rail XR100 Rail XR1000 Rail Bonded Splices GREEN THINK ENERGY LLC 50 HARRISON STREET, �� SUITE 202B III HOBOKEN,NJ 07030 I i www.GreenThinkEnergy.com ____...1 .....,......_1 ____________... CONTRACTOR NAME:N/A f._ ADDRESS:N/A A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices PHONE#:N/A for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. LICENSE#:N/A • 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-drilling screws REVISIONS • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails DESCRIPTION DATE REV • Clear and black finish • Clear and black finish • Clear anodized finish • Forms secure bonding s71 ' Clamps & Grounding e — �' �' MI— SIGNATURE&SEAL �� UFOs Stopper Sleeves Grounding Lugs Microinverter Kits illb.�� '":1101 � Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount Mls or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. PROJECT NAME • Fully assembled&lubed • Bonds modules to rails • Low profile • Bonds devices to rails • Single, universal size • Sized to match modules • Single tool installation • Kit comes assembled Q • Clear and black finish • Clear and black finish • Mounts in any direction • Listed to UL 2703 0) Built for solar's toughest roofs. D Attachments e — Z IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to N the limit and proven in extreme environments. FlashFoot2 Slotted L-Feet Bonding Hardware Flush Standoffs 0 N Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and — _ — 0 09 — .-, a is also why our products are fully certified, code compliant and backed by a 20-year warranty. i i Q rui4—,,,Tifi.„ < ... hale; Strength Tested PE Certified - — — �? � _ - w m co laAll components evaluated for superior Q Pre-stamped engineering letters Flash and mount XR Rails Drop-in design for rapid rail Bond and attach XR Rails Raise Flush Mount System ~ structural performance. available in most states. with superior waterproofing. attachment. to roof attachments. to various heights. w in • Twist-on Cap eases install • Secure rail connections • T&Square Bolt options • Works with vent flashing �� O �/•� • Wind-driven rain tested • Slot for vertical adjusting • Nut uses 7/16"socket • 4"and 7"lengths v J Q 6 Class A Fire Rating Certified to maintain the fire resistance JJ1 Design Assistant • Mill and black finish • Clear and black finish • Assembled and lubricated • Ships assembled Z Online software makes it simple to Q - rating of the existing roof. create, share, and price projects. Resources I _ Design Assistant ORFPFpp, NABCEP Certified Training SHEET NAME UL 2703 Listed System 20-Year Warranty eft 0 Go from rough layout to fully NABCEP Earn free continuing education credits, EQUIPMENT _ engineered system. For free. 0 Go to IronRidgecom/design while learning more about our systems. O Entire system and components meet Twice the protection offered by _ . Go to IronRidge.com/training SPECIFICATION newest effective UL 2703 standard. competitors. I SHEET SIZE ANDS I B w.©2016 IronRidge,Inc.All rights reserved.Visit wwironridge.com or call 1-800-227-9523 for more information.Version 1.30 1 1" X 1 7" SHEET NUMBER PV-10 MEEK 'MAE Tech Brief Tech Brief H J��EJ Uow /lr IRON RI DGE Integrated Grounding System Installation Overview GREEN THINK ENERGY LLC 50 HARRISON STREET, SUITE 202B Install Roof Attachments HOBOKEN,NJ 07030 Simplified Grounding www.GreenThinkEnergy.com 1 • Install appropriate roof flashing and/or standoff for roof type. 1 CONTRACTOR For Greater Safety & Lower Cost •Attach L Feet to flashing or standoff. NAME:N/A ADDRESS:N/A Traditionally, solar modules are grounded by attaching ,� PHONE#:N/A lugs, bolts or clips to the module frame, then connecting LICENSE#:N/A Prepare Rail Connections ��/ these to a copper conductor that runs throughout the o, REVISIONS array.This process adds time and cost to the installation, • Insert splice into first rail, then secure with Grounding Strap and �` /! DESCRIPTION DATE REV and often results in improper grounding, creating self-drilling screw. �\ significant long term safety risks. • Slide second rail over splice,then secure with opposite end of r The IronRidge Integrated Grounding System solves these Grounding Strap and self drilling screw. challenges by bonding modules directly to the mounting SIGNATURE&SEAL rails.This approach eliminates separate module — grounding hardware, and it creates many parallel Ilil nMount&Ground Rails grounding paths throughout the array, providing •Attach rails to L-Feet and level rails. 4 greater safety for system owners. Grounding Mid Clamp • Install one Grounding Lug per row of modules. Each Grounding Mid Clamp pierces through the • Connect GroundingLugto groundingconductor. anodized coatings of both the module frame and the mounting rail to form secure electrical bonds, which are repeated throughout the array. ®���������/ tV� Install Modules&Clamps PROJECT NAME I 40 • Install first module usingEnd Clamps and GroundingMid Clamps.�I// /j /I �/I/ pQ �j��41W�/ // �I �/ 4 '��/ • Install additional modules using Grounding Mid Clamps. �/��/��/I����� ��•� �//�/�// Asp • Finish row with a second pair of End Clamps. #41Tr I��11Ai0i /k,_, 04‘4 /I //1 /1i Testing & Certification ®w/ �� / :-, • / i /��//•//�//•/ r.,31Module Frame Compatibility J dir,/ / �� _ �/ / �/ The IronRidge Integrated Grounding 03 40 7��� r, /4,e_ — • .���� �/�/� System has been tested and certified to I Dimension Range w Q ��-- �00/ • �y /� � �� UL 2703 by Intertek Group plc. A 31.Omm 51.0mm W m `� �� 77 'E/4"; �� I, UL 2703 is a proposed UL standard B 5.08mm (minimum) in B7 I--- �\ �i for evaluatingsolar module mounting/® �� fl Any module frames whose parameters are not listed in the 0 �j� and clamping devices. It ensures these provided table have not been tested for compatibility. /�/ ��® 0 devices will maintain strong electrical and (f� `�� \\�� mechanical connections over an extended �� / period of time in extreme outdoor The Grounding Clamp has proven robust in grounding 60-cell and z I/I environments. 72-cell solar module frames with box construction and a range of Q / -.1'v / / anodization thicknesses. �• "y, The testing process closely mirrors that All solar modules listed to UL 1703 and with frame construction Grounding Strap , i 1 of UL 1703,the solar module testingSHEET NAME Grounding Straps are used to within the parameters stated above are compatible with the 9. =="'r bond rail-to-rail connections. standard, including temperature and IronRidge Integrated Grounding System. EQUIPMENT Grounding Lug humiditycycling, SPECIFICATION "` They are only required on the electrical and mechanical A single Grounding Lug rail with the grounding lug. connects an entire row load testing, and manufacturing quality O Go to ironridge.com/ig of PV modules to the reviews. grounding conductor. SHEET SIZE ANSI B 11" X17" ©2013 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information. SHEET NUMBER PV-11 c(101 , D IRONRIDGE UFO Family of Components System Diagram rl gW' GREEN THINK ENERGY LLC 50 HARRISON STREET, SUITE 202B Simplified Grounding for Every Application _ HOBOKEN,NJ 07030 MIO _O_ _ _ : __O O • 4 _= www.GreenThinkEnergy.com The UFO family of components eliminates the need for CONTRACTOR separate grounding hardware by bonding solar modules NAME:N/A directly to IronRidge XR Rails.All system types that feature ADDRESS:N/A PHONE#:N/A LICENSE#:N/A the UFO family—Flush Mount,Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. ow ) 0 O- - - _ - - O 4 'aREVISIONS UFO hardware forms secure electrical bonds with both the DESCRIPTION DATE REV module and the rail, resulting in many parallel grounding paths throughout the system.This leads to safer and more reliable installations. Ell) O O- _ _m_ _ _ O • 4 = SIGNATURE&SEAL illik Stopper Sleeve Universal Fastening Object(UFO) The Stopper Sleeve snaps The UFO securely bonds solar modules to XR onto the UFO,converting it into Rails.It comes assembled and lubricated,and a bonded end clamp. can fit a wide range of module heights. E. O O_ _ :LE: _ __ _ _m__ _ _O O , _ \ / ,, ��® PROJECT NAME. /7 j/� .r, ���,w��y�w/g� . �-�\ O UFO Stopper Sleeve • Grounding Lug I-T-I Bonded Splice _ Ground Wire D JI �j��/.�, /�jjv.%fir �•..- ", �� Q Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for � (v y����y/���,�p��/%`, �; grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the 4r(Pi� ,��,�—..�/I �� same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. 0 � � ��ii m • Y Q � w -,� ` UL Certification Q � `� Cross-System Compatibility W J Uj i m , 4P4.``'��" �� The IronRidge Flush Mount, Feature Flush Mount Tilt Mount Ground Mount > in H in Al ��j � �_' Tilt Mount, and Ground Mount XR Rails d XR1000 Only W N— fl Bonded Splice �-.� / Systems have been listed to UL Each Bonded Splice uses \� / a \;'ry// 2703 by Intertek Group plc. UFO/Stopper V V V U self-drilling screws to form ' `� a secure connection.No Fli Bonded Splice �/ d N/A Z bonding strap needed. MD//A UL 2703 is the standard for - — evaluating solar mounting Grounding Lugs 1 per Row 1 1 per Row 1 per Array Q — systems. It ensures these devices Microinverters Enphase-M250-72, M250-60, M215-60,C250-72 . will maintain strong electrical and &Power Darfon-MIG240, MIG300, G320, G640 Grounding Lug mechanical connections over A single Grounding Lug Bonded Attachments Optimizers SolarEdge P300, P320, P400, P405, P600, P700, P730 SHEET NAME connects an entire row The bonding bolt attaches an extended period of time in _ of PV modules to the and bonds the L-foot to the extreme outdoor environments. Fire Rating Class A Class A N/A EQUIPMENT nor . .It i SPECIFICATION Ismgrounding conductor. Tested or Evaluated with over 400 Framed Modules same rail socket is asnstalled thewith restthe of the Modules system. O Go to IronRidge.com/UFO Refer to installation manuals for a detailed list. SHEET SIZE ANSI B ©2016 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.0 11�� /� 17" SHEET NUMBER PV-12