HomeMy WebLinkAboutPermit File 5512 Doon Way BUILDING PERMIT 0
CITY OF ANACORTES PERMIT NO.: BLD2001-00192
P.O. BOX 547 APPLIED: 6/22/01
ANACORTES, WA 98221 ISSUED: 6/22/01
(360)293-1901 EXPIRES: 6122102
SITE ADDRESS: 5512 DOON
ASSESSOR'S PARCEL NO.: 3823-000-073-0001
PROJECT DESCRIPTION: Reroof single family residence.
OWNER CONTRACTOR
JEFF MORRIS
5512 DOON WAY
ANACORTES,WA 98221
Primary Phone: Primary Phone:
Phone 1: 293-6910 Phone 1:
License#:
TYPE OF WORK: ROF AREA VALUE: $ 2,500.00
TYPE OF USE: SF LOT: sf REQUIRED SETBACKS:
CENSUS CATEGORY:
FLR: sf
ZONING: ? 1ST2NDFLR: sf ft FRONT:
Occupancy Groups BASEMENT: sf SIDE 1: ft
GAR/CARPORT: sf SIDE 2: ft
1: R3 2: OTHER: sf REAR: ft
3: 4:
REQUIRED PARKING
Construction Types NUMBER OF UNITS: TOTAL:
1: 5N 2: STORIES: HANDICAPPED:
3: 4: BUILDING HEIGHT: ft COMPACT:
IMPRV SURF: sf
FEES NOTES:
Type By Date Receipt Amount
PRMT MRD 6/22/01 0106599 $38.50
STBC MRD 6/22/01 0106599 $4.50
Total: $43.00
I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply
with all ordinances and state and federal laws regulating activities cover d b tjis permit.
Issued by Applic nt r v r�r's Signature
CONDITIONS OF APPROVAL:
24 Hour Notice Required For All Inspections
MECHANICAL PERMIT
CITY OF ANACORTES PERMIT NO. : MEC96-0088
P.O. BOX 547 APPLIED: 09/30/96
ANACORTES, WA 98221 ISSUED: 09/30/96
(206) 293-1901 EXPIRES: 09/30/97
SITE ADDRESS: 5512 DOON
ASSESSOR'S PARCEL NO. : 3823-000-073-0001
PROJECT DESCRIPTION: Gas furnace and gas piping
— OWNER — CONTRACTOR
JEFF NORRIS HANDY'S HEATING
5512 DOON WAY
ANACORTES WA 98221 SEDRO WOOLLEY WA 98284
293- 856-2654
HANDYHIO88JN
TYPE OF WORK. . . :ADD BOILERS/COMPRESSORS- DOMES. INCIN • 0
TYPE OF USE •RES 0-3 HP • 0 COMML. INCIN • 0
3-15 HP • 0 RELOC/REPAIR. . . : 0
FUEL TYPES 15-30 HP • 0 CLOTHES DRYERS. : 0
: /GAS/ / / : 30-50 HP • 0 GAS WTR HEATERS: 0
FURN < 100K BTU: 1 50+ HP • 0 STOVE, APPLI. . . : 0
FURN >=100K BTU: 0 AIR HANDLING UNITS-- FIRE LOG/LITE. . : 0
FURN - FLOOR. . . : 0 <= 10000 cfm. : 0 WOODSTOVES • 0
UNIT HEATERS. . . : 0 > 10000 cfm. : 0 OTHER UNITS • 0
VENT FANS • 0 EVAP COOLERS. . . : 0 GAS OUTLETS • 1
VENT SYSTEMS. . . : 0 HOODS • 0
VENT W/O APPLI. : 0
— FEES — NOTES
Code Amount---- By- Date---- Receipt
PRMT $ 40.75 MD 09/30/96 5983
TOTAL $ 40.75
I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all
ordinances and Laws regulating activities covered by this permit.
Issued by Applicant or Owner's Signature
24 Hour Notice Required For All Inspections
mec_prmt, Rev: 06/11/92
- CITY OF ANACORTES
BUILDING DEPARTMENT
CERTIFICATE OF OCCUPANCY
6 4
THIS IS TO CERTIFY that the (description of building
or structure):ths---
....0Q,...4-ekter ELL-4-4-v-0-1
09
(2,426A.R,
Owner: 14-Seict-0-4 Cilt..
Street and No S I 2 — 03-6-1AW—am.
Contractor: ee'lL-0..)--At"r-a— Fire Zone•
Building Permit No • it S 3 19
Occ. Group: it 3 Use Zone: P-has been inspected and occupancy is hereby
authorized:
tics ° 197
(' Th,
N'-‘\a'A-1
Building Inspector
APPLICATION FOR BUILDING PERMIT
CITY OF ANACORTES
Date / /- i 4 -1 g
Owner's Name / ea/ld S/71/F4C ,y
Owner's Address 2/ I? - i •Z ( eLee-,X6� (cPhone No.
Applicant's Name (9W,VF.
Applicant's Address Phone No.
Property Address 557Z / oo,v 3 49 7-
I
Legal Description of Property //)l 7 Z/// 7 LSI t-) 9A-r
Description of proposed improvement it4?7,I ,5,/-7 itaFj//ocWY 4.c
Yr.P '/€s7— 2/4.4%s Cor�,e�rTo ,a't oG PZ.e) c- .94
LAD/ CJVr/f .1/0/7's /UD �'�i9�tro�j Gvi7//Ov7-
('O,f457A/T//1/G
Improved property to be used as follows S frr7 5721l.) 2ric
Value of proposed improvement $ 3 L/-/ Y ��
PLOT PLAN _ l yre * fld9O • -/5.00
Instructions: Draw a sketch of the property on the reverse side of this page
or submit plot plan showing the following information:
1. Streets and alleys abutting property. •
2. North point.
3. Size and shape of property.
4. Size of existing building or improvements.
5. Size of proposed buildings or improvements.
6. Distance of all structures from all property lines.
A licant's or agent's signature
Sign only after reading attached
• building permit requirements.
PERMITS ISSUED
I D:o9,Ess' , 5-42 •.2- 00.44 f/A2
s7 ,,./j- Lct- —73 a (U7
TYPE PEP4IT NC. INSPECTIONS
•
453%
- BLDG.
•
97026
PMBING
t
GAS I �i
SEWER
CSC.
-' --_' / I �.
tf539 - zw 04. ..GeDv.t.e, )1-r`E-78 •
e/7a6 - � -�Gt'�. �� �� 4-/9-77
57.5-/C7 D D 6 0 (C)CIA .
v_Ahc>s� U
II o3'z9�48" R. . • 13aO� a03•act 004
30' ° 63.00' 81.50' •
>-[>"
NJ in
u3 in I' m
in
,. m
il
o co W 73 N. co T72. a 7f
0 30 • Co iu
0;-.I • - - - --, 0 ci i
0 F I in
in
O. I 0
i
v,�2 I 2
• 59.2a'
- - • 75.64'
•
a to1
'4 O
O in
_______________ .s. ar4 oo_g-.
sO6.584 DCON
---WAY --__ — O
i
I
SURVEYS FOR
HAROLD STEVENS
l
Oct . & Nov. , 1978
Lots 72 and 73 , plat of Skyline No. 7,
Anacortes, Washington .
scale.: 1"= 30' \( n",iS T E'.LE'n' 4,
Mon. Found: 0 1,`c "'"`•"5 If
Van Pipe Set: O c t
-40:tel. 2
WaSh. Cart. i84303
11 - 14-78