Loading...
HomeMy WebLinkAboutPermit File 3710 Leeward Lane ' SUPERIOR INSULATION CERTIFICATION CARD Insulation Contractor Name: SUPERIOR INSULATION PRODUCTS Jobsite Contractor: STRANDBERG CONSTRUCTION Job Name: INS Jobsite Address: 3710 LEEWARD LANE ANACORTES WASHINGTON 98221 Ceiling Insulation Manufactures Name: Certainteed Certainteed Certainteed Insulation Type: Fiberglass Blown Fiberglass Batts Fiberglass Batts R-Value of Insulation: R49 R49 R21 Thickness of Insulation Installed: 16" 13.5" 5.5" Location of Insulation Installed: Ceiling Area Ceiling Area Ceiling Area Wall Insulation Manufactures Name: Certainteed Insulation Type: Fiberglass Batts R-Value of Insulation: R21 Thickness of Insulation Installed: 5.5" Location of Insulation Installed: Exterior Walls Floor Insulation Manufactures Name: Certainteed Insulation Type: Fiberglass Batts R-Value of Insulation: R38 Thickness of Insulation Installed: 12" Location of Insulation Installed: Crawl Space THIS CARD MUST BE POSTED IN A PROMINENT LOCATION AND RETURNED TO THE BUILDING DEPARTMENT BEFORE YOUR FINAL INSPECTION KaylieJKlevvyp SUPERIP833KT .nsulation Contractors Signature License# 4/29/2019 Date E e WASH INUTcN STATE UNIVERSITY_ s it /7' pC11" t EXTENSION ENERGY PROGRAM R•-sidential Building Air Leakage Test (Blower Door Test) Results Permit #: Cd ( !v House address sr lot number: 7 ( 0 L e W AP) L b , City: /` kl otL v r Zip: Cond. Floor Are- (ft2): 9"D Age of house: 0 Source (circle on-): Pla Estimated Measured Results shall be -ported as Air Changes per Hour at 50 Pascals (ACH50) and shall be calculated as follows: ACH50 = CFM50 x 60)/ Volume Where: CFM50 - Blower door fan flow at 50 Pascal pressure difference Volume Conditioned Floor Area of the housing unit x ceiling height Blower Door Te-t Result: /' Z ACH50 9 & 0 CFM@50Pa Ring (circle one if .pplicable): Open B C Blower Door Fan ocation: 1,.,1-1A5 c. r Weather Conditions: I certify that th t. e blower door results are accurate and determined using standard industry protocol. Company Name: H(`'41)y1 tile-ij f t, Technician: L, Technician Signat nre: kl--1 1/,� Date: 7 o f Phone Number: Z Q b Ct 2012 Washington S -te Energy Code reference: R402.4.1.2 Tes ing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air ' hanges per hour in Climate Zones 1 and 2, and 3- 5 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, te- ing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the pa ty conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Once visual inspection has confirmed the presence of a gasket (see Section 502.4), operable windows and doors manufactured by small business shall be permitted to be sealed off at the came prior to the test.