INSULATION CERTIFICATION CARD
Insulation Contractor Name: SUPERIOR INSULATION PRODUCTS
Jobsite Contractor: STRANDBERG CONSTRUCTION
Job Name: INS
Jobsite Address: 3710 LEEWARD LANE ANACORTES WASHINGTON 98221
Ceiling Insulation
Manufactures Name: Certainteed Certainteed Certainteed
Insulation Type: Fiberglass Blown Fiberglass Batts Fiberglass Batts
R-Value of Insulation: R49 R49 R21
Thickness of Insulation Installed: 16" 13.5" 5.5"
Location of Insulation Installed: Ceiling Area Ceiling Area Ceiling Area
Wall Insulation
Manufactures Name: Certainteed
Insulation Type: Fiberglass Batts
R-Value of Insulation: R21
Thickness of Insulation Installed: 5.5"
Location of Insulation Installed: Exterior Walls
Floor Insulation
Manufactures Name: Certainteed
Insulation Type: Fiberglass Batts
R-Value of Insulation: R38
Thickness of Insulation Installed: 12"
Location of Insulation Installed: Crawl Space
THIS CARD MUST BE POSTED IN A PROMINENT LOCATION AND RETURNED TO THE BUILDING DEPARTMENT BEFORE
YOUR FINAL INSPECTION
KaylieJKlevvyp SUPERIP833KT
.nsulation Contractors Signature License#
4/29/2019
Date
E e
WASH INUTcN STATE UNIVERSITY_
s it /7' pC11" t EXTENSION ENERGY PROGRAM
R•-sidential Building Air Leakage Test (Blower Door Test) Results
Permit #: Cd ( !v
House address sr lot number: 7 ( 0 L e W AP) L b ,
City: /` kl otL v r Zip:
Cond. Floor Are- (ft2): 9"D Age of house: 0
Source (circle on-): Pla Estimated Measured
Results shall be -ported as Air Changes per Hour at 50 Pascals (ACH50) and shall be calculated as follows:
ACH50 = CFM50 x 60)/ Volume
Where:
CFM50 - Blower door fan flow at 50 Pascal pressure difference
Volume Conditioned Floor Area of the housing unit x ceiling height
Blower Door Te-t Result: /' Z ACH50
9 & 0 CFM@50Pa
Ring (circle one if .pplicable): Open B C
Blower Door Fan ocation: 1,.,1-1A5 c. r Weather Conditions:
I certify that th t. e blower door results are accurate and determined using standard industry protocol.
Company Name: H(`'41)y1 tile-ij f t, Technician: L,
Technician Signat nre: kl--1 1/,� Date: 7 o f Phone Number: Z Q b Ct
2012 Washington S -te Energy Code reference:
R402.4.1.2 Tes ing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding 5 air ' hanges per hour in Climate Zones 1 and 2, and 3- 5 air changes per hour in Climate Zones 3 through 8.
Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the
code official, te- ing shall be conducted by an approved third party. A written report of the results of the test shall be
signed by the pa ty conducting the test and provided to the code official. Testing shall be performed at any time after
creation of all penetrations of the building thermal envelope. Once visual inspection has confirmed the presence of a
gasket (see Section 502.4), operable windows and doors manufactured by small business shall be permitted to be
sealed off at the came prior to the test.