HomeMy WebLinkAboutPermit File BLD-20190529 3943 Rock Ridge Parkway!SUPERI R,
INSULATION CERTIFICATION CARD
Insulation Contractor Name:
Jobsite Contractor:
Job Name:
Jobsite Address:
SUPERIOR INSULATION PRODUCTS
STRANDBERG CONSTRUCTION
N/A
3943 ROCKRIDGE PARKWAY ANACORTES, WA 98221
Ceiling
Insulation
Manufactures Name:
Knauf
Nexseal
Knauf
Insulation Type:
Fiberglass Batts
Spray Foam
Fiberglass Batts
R-Value of Insulation:
R38
R22
R49
Thickness of Insulation Installed:
12"
3"
115"
Location of Insulation Installed:
Cathedral Vault
Ceiling Area
Ceiling Area
Wall
Insulation
Manufactures Name:
Knauf
Insulation Type:
Fiberglass Batts
R-Value of Insulation:
R21
Thickness of Insulation Installed:
55'
Location of Insulation Installed:
Exterior Walls
Floor
Insulation
Manufactures Name:
Knauf
Insulation Type:
Fiberglass Batts
R-Value of Insulation:
R38
Thickness of Insulation Installed:
12"
Location of Insulation Installed:
Crawlspace
THIS CARD MUST BE POSTED IN A PROMINENT LOCATION AND RETURNED TO THE BUILDING DEPARTMENT BEFORE
YOUR FINAL INSPECTION
Kdv,�y Mci vw SUPERIP833KT
Insulation Contractors Signature
07,16.2020
Date
License #
Residential Building Air Leakage lest (Blower Door Test) Results
Permit # . `VUVI( V S1ew�
House address or lot number:
Cond. Floor Area (ftZ): 3
Source (circle one): lans
Zip: -I Z2 1
Age of house: NE I&J
Estimated
Measured
Results shall be reported as Air Changes per Hour at 50 Pascals (ACH50) and shall be calculated as follows:
ACH50 = (CFM50 x 60)/ Volume
Where:
CFM50 =Blower door fan flow at 50 Pascal pressure difference
Volume = Conditioned Floor Area of the housing unit x ceiling height
Blower Door Test Result: ,r •_'T ACH60
7, CFM@50Pa
Ring (circle one if applicable):
Open
Blower Door Fan Location; I'�0�� 1�G7�1� Weather Conditions: ` 1�T 1�
I certify that these blower door results are accurate and determined using standard industry protocol.
Company
Technician: � ki � I !� (��,/t/(()tzA
Technician Signature: � v�--� Date: I 2.OPhone Number: �(9 ^ 113
2015 Washington State Energy Cade reference;
R402AAsA Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g, (50
Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written resort
of the results of the test shall be siened by the party conduetine the test and provided to the code of
rcial Testing
shall be performed at any time after creation of all penetrations of the building thermal envelope. Once visual
inspection has confirmed sealing (see Table R402.4.1.1), operable windows and doors manufactured by small business
shall be permitted to be sealed off at the frame prior to the test.
Duct Leakage Affidavit (New Construction)
Permit #:
douse address or lot number:
City:
Cond. Floor Area (ft2):
l6 z G
Source (circle one): Plans
Estimated Measured
❑ Duct tightness testing is not required. The total leakage test is not required for ducts and air handlers located
entirely within the building thermal envelope. Ducts located in crawl spaces do not qualify for this exception.
Air Handler in conditioned space? ❑yes ❑ r�o Air handler present during test? ❑yes ❑ no
Circle Test Method: Leakage to Outside Total Leakage
Maximum duct leakage:
Post Construction, total duct leakage: (floor area x .04) = CFM@25 Pa
Post Construction, leakage to outdoors: (floor area x .04) = CFM@25 Pa
Rough -In, total duct leakage with air handler installed: (floor area x .04) = CFM@25 Pa
Rough -In, total duct leakage with air handler not installed: (floor area x .03) = CFM@25 Pa
Test Result: CFM@25Pa
Ring (circle one if applicable):
Duct Tester Location: V` I I
Open
1
E
Tap Location:
Pressure
3
I certify that these duct leak
age rates are accurate and determined using standard duct testing protocol.
Company Name:
Technician Signature:
Date:
Phone Number:
Technician: