HomeMy WebLinkAboutPermit File BLD-20190529 3943 Rock Ridge Parkway!SUPERI R, INSULATION CERTIFICATION CARD Insulation Contractor Name: Jobsite Contractor: Job Name: Jobsite Address: SUPERIOR INSULATION PRODUCTS STRANDBERG CONSTRUCTION N/A 3943 ROCKRIDGE PARKWAY ANACORTES, WA 98221 Ceiling Insulation Manufactures Name: Knauf Nexseal Knauf Insulation Type: Fiberglass Batts Spray Foam Fiberglass Batts R-Value of Insulation: R38 R22 R49 Thickness of Insulation Installed: 12" 3" 115" Location of Insulation Installed: Cathedral Vault Ceiling Area Ceiling Area Wall Insulation Manufactures Name: Knauf Insulation Type: Fiberglass Batts R-Value of Insulation: R21 Thickness of Insulation Installed: 55' Location of Insulation Installed: Exterior Walls Floor Insulation Manufactures Name: Knauf Insulation Type: Fiberglass Batts R-Value of Insulation: R38 Thickness of Insulation Installed: 12" Location of Insulation Installed: Crawlspace THIS CARD MUST BE POSTED IN A PROMINENT LOCATION AND RETURNED TO THE BUILDING DEPARTMENT BEFORE YOUR FINAL INSPECTION Kdv,�y Mci vw SUPERIP833KT Insulation Contractors Signature 07,16.2020 Date License # Residential Building Air Leakage lest (Blower Door Test) Results Permit # . `VUVI( V S1ew� House address or lot number: Cond. Floor Area (ftZ): 3 Source (circle one): lans Zip: -I Z2 1 Age of house: NE I&J Estimated Measured Results shall be reported as Air Changes per Hour at 50 Pascals (ACH50) and shall be calculated as follows: ACH50 = (CFM50 x 60)/ Volume Where: CFM50 =Blower door fan flow at 50 Pascal pressure difference Volume = Conditioned Floor Area of the housing unit x ceiling height Blower Door Test Result: ,r •_'T ACH60 7, CFM@50Pa Ring (circle one if applicable): Open Blower Door Fan Location; I'�0�� 1�G7�1� Weather Conditions: ` 1�T 1� I certify that these blower door results are accurate and determined using standard industry protocol. Company Technician: � ki � I !� (��,/t/(()tzA Technician Signature: � v�--� Date: I 2.OPhone Number: �(9 ^ 113 2015 Washington State Energy Cade reference; R402AAsA Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g, (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written resort of the results of the test shall be siened by the party conduetine the test and provided to the code of rcial Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Once visual inspection has confirmed sealing (see Table R402.4.1.1), operable windows and doors manufactured by small business shall be permitted to be sealed off at the frame prior to the test. Duct Leakage Affidavit (New Construction) Permit #: douse address or lot number: City: Cond. Floor Area (ft2): l6 z G Source (circle one): Plans Estimated Measured ❑ Duct tightness testing is not required. The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope. Ducts located in crawl spaces do not qualify for this exception. Air Handler in conditioned space? ❑yes ❑ r�o Air handler present during test? ❑yes ❑ no Circle Test Method: Leakage to Outside Total Leakage Maximum duct leakage: Post Construction, total duct leakage: (floor area x .04) = CFM@25 Pa Post Construction, leakage to outdoors: (floor area x .04) = CFM@25 Pa Rough -In, total duct leakage with air handler installed: (floor area x .04) = CFM@25 Pa Rough -In, total duct leakage with air handler not installed: (floor area x .03) = CFM@25 Pa Test Result: CFM@25Pa Ring (circle one if applicable): Duct Tester Location: V` I I Open 1 E Tap Location: Pressure 3 I certify that these duct leak age rates are accurate and determined using standard duct testing protocol. Company Name: Technician Signature: Date: Phone Number: Technician: