Loading...
HomeMy WebLinkAboutPermit File 3912 Cottage Place » E Sewer cc CITY OF ANACORTES AS—BUILT Stoaa CONTRACTOR: 746<g C G- PLATIDIVIS[ON: J )es BLOCK LOT ADDRESS: 37/--- � � n DATE: 7 - 3 [ --O7 PERMIT# SCALE S : TR EE 110111111/111 it ls1 a _ E I ' � - I LOCATE STREET(S)ON GRID MAP • 4‘ Y °•4‘ CITY OF ANACORTES WASHINGTON • BUILDING DEPARTMENT CERTIFICATE OF OCCUPANCY ' This is to certify that the(Description of Building or Structure): Single Family Residence Located At: 3912 Cottage Place STREET&NUMBER Owner: Habitat Construction Constructed By: Habitat Construction OWNER OR CONTRACTOR Bldg. Permit#: BLD-2006-0224 Date Issued: September 16, 2006 Occ.Group: R-3 Use Zone: R2 Has Been Inspected And Occupancy Is Hereby Authorized. This 7th Day of March 20 11. A 1-1CRI4IN F I SEE REVERSE SIDE FOR SPECIAL.REQUIREMENTS. ' 4 4. . � 5D - Public Works . Engineering and Development Services • Residential Inspection Address: 3s Z - COT[jt6� t _ Date: j 1 Ii l/D Owner: Vk1A 4'1-4 l/•) TtiILU OIO Contractor: �y1-T-y}-- l u "Cli1t�_Tlb ' Inspected Pe by: .�► VI\.%tAl.t,tztZ 1. Water _er Box Se and level to finished grade or backside of sidewalk elevation. id and box undamaged. E r meter and customer shutoff installed. . lig1KNo debris. nli accessible—no landscape obstruction. j D ' y installation has drive-over box and lid_ Customer gate valve intact. [ 6-leaks at connections. ` 2. Curb and Gutter ❑ No cracks, damage, graffiti, footprints, finishing blemishes, or other objectionable marks. If road frontage improvements: ❑ Expansion joints every 15 feet and at driveways. D Concrete has broom finish. DNo low spot at curb line, especially at driveway cut. Maximum grade change in 20 feet is % inch. 1/4 3. Sidewalk NNN ❑ No cracks, damage, graffiti, footprints, finishing blemishes, or other objectionable marks. ❑ ADA compliant— 1 percent slope to curb. . If road frontage improvements: ❑ Expansion joints every 15.feet and at driveways. - ❑ Concrete has broom finish - 4. Driveway Approaches tiallo racks, damage, graffiti, footprints, finishing blemishes, or other objectionable arks. ADA compliant. r r - y • - " 5: Streets ❑ No cracks, blemishes. -If road or alley improvements: ' - - - • - - ❑ - Received proctor and sieve analysis of ballast, crushed rock, and asphalt. ❑ Received passing materials testing reports for sub-grade, ballast, crushed rock, and asphalt. - ❑ Received tonnage tickets consistent with required thickness per approved . - plans. - 6. Sanitary S er inspection card signed off and/or verified in Building Department database. . [ems--built record filed in the address file. - • / [ircew cap(s).installed on clean-out(s). Clean-out(s)set at finished grade. V " 7. Storm Drainage nspection-card signed off.and/or verified in Building Department database. Er-kg-built record filed in address file. 'Not blocked or diverted to adjacent parcel. r v > -Public Utilities Out of Traveled Way ❑ Concrete collars around City utilities. - ❑ Final grading ok. - : ❑ Restored to prior condition or better.'QLQaiZ - 9. Landscape J.S?c1 c j j,. ......_ ❑ Bonded for completion at later date. Verified against approve d landscape plan: r.-------'--- E�nstallation_ - 9-1 pe and quantity of plants. [�Soor.seed in place. f barrier(receipt filed). • 10.Erosion trot Measures . s removed. FIWAII ris removed. Site clean. ermanent vegetation established. 39/20zYct,ye_e 1,74eCQ x J 8,t �I t \> 1 AAA i_ NSA t\ �s A _ \\A ,.j 'T A. {!\ f .Rti , O ..I -_'. ..I I li I II. II '�I:. I 1 ` ..I, I Ikl. , .. -� I� I '� '. r �• .I II ......_ • -" O I: ` O Y Gale Contractor Services A Masco Contractor Services Company a ;Jr 16910 59th Ave. NE, Suite 100 Arlington, WA 98223 k j` Installed Insulation Certificate =% y 'We certify that insulation material listed here and installed at the following residence K - surrounding conditioned space meed applicable federal,state and local specifications." ` V } Looea FIN Kraft Unlaced Fall Foam on R-Ydw Ara Thickness No.Pkge Coverage A -',{y Coifing. CR 0 CI ❑ 0 4$.._.._._. ...18,5. _ te a -< '> Floors 0 0 0 0 ❑ 0 .! Walk 0 0 ❑ ❑ 0 22 7 6" 64 r • i easement ❑ ❑ ❑ ❑ ❑ ❑ < • com► it& Jennifer A. Govern Addmsor Lot Number. 3912 Cottage Place .� 1 Y. (Signature) , 1 x City,ST,ap: Anacnrtw� i{ Washington • 'Mk Production Assistant Date instated: June 3 2010 II >,,,,, Mmarmn0008,801 1,4 .� ./°, a 4 r S}r �,[7y Y j t. + fe S7L �ti I' \ v V te R A./ i. 1/ / . mi 1q l } F. TR Preto.;(702)871-3018 1006404-1 0002 03105,2010 002 4 Permit Fees 005678 $341 .50 AZT` Y Q .- City of Anacortes permit#: BLD-2006-0224 904 6th Street Issue date: 09/16/2008 P.O.Box 547 Expire date: 09/0112011 ''Y' UJ Anacortes, WA 98221-0547 =�' I ` .,' (360) 293-1901 Job Address: 3912 COTTAGE PL Permit Type: Single Family Residence Permit ANACORTES WA 98221-1274 Project: APN: Remarks: New single family residence. Owner: HABITAT CONSTRUCTION Contractor: Address: 12940 SUNSET LN Address: ANACORTES WA 98221-8525 Phone: (360)293-8215 Phone: License#: General Information: Fees: Basement Square Footage 235 Plan Review Deposit 100.00 1st Floor Square Footage 720 Building Permit Fee 683.00 2nd Floor Square Footage 493 Plan Review Fee 343.95 Building Valuation 200000 Mechanical Permit Fees 100.15 # Forced Air Furnace<=1,000 1 Plumbing Permit Fee 111.00 #of Bathtubs 1 State Building Code Fee 4.50 #of Clothes Dryers 1 Sewer Inspection Fee 50.00 #of Clothes Washers 1 Storm Drain GFC-Residential 1,140.00 #of Dishwashers 1 Sewer GFC-Residential 6,592.00 #of Gas Fireplace 1 Park Impact Fee 615.00 #of Gas Piping 1 Traffic Impact Fee 900.00 #of Gas Water Heaters 1 Renew Building Permit Fee 341.50 #of Water Piping 1 Total Calculated: 10,981.10 #of Hose Bibbs 2 Deposits/Receipts: 10,639.60 #of Kitchen Sinks 1 #of Lavatories 2 Total Due: 341.50 #of Range Hoods 1 #of Showers 2 #of Ventilation Fans 2 #of Water Closets 2 THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR CAL LAW REGULA NG CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. SIGNATU 0 NER OR AUTHORIZED AGENT ISSUED BY 0 260:i4-1 0001 09,i 200S 002 4 Panntlit Fees 00 6�7t $11.:y539.60 ;GS"P 0 ., City of Anacortes Permit#: BLD-2006-0224 ! 904 6th Street Issue date: 09/16/2008 P.O.Box 547 $?+• iti, Anacortes, WA 98221-0547 Expire date: 09/16/2009 �'� - (360)293-1901 Job Address: 3912 COTTAGE PL Permit Type: Single Family Residence Permit ANACORTES WA 98221-1274 Project: APN: Remarks: New single family residence. Owner: HABITAT CONSTRUCTION Contractor: Address: 12940 SUNSET LN Address: ANACORTES WA 98221-8525 Phone: (360)293-8215 Phone: License#: • General Information: Fees: Basement Square Footage 235 Plan Review Deposit 100.00 1st Floor Square Footage 720 Building Permit Fee 683.00 2nd Floor Square Footage 493 Plan Review Fee 343.95 Building Valuation 200000 Mechanical Permit Fees 100.15 # Forced Air Furnace<=1,000 1 Plumbing Permit Fee 111.00 #of Bathtubs 1 State Building Code Fee 4.50 #of Clothes Dryers 1 Sewer Inspection Fee 50.00 #of Clothes Washers 1 Storm Drain GFC-Residential 1,140.00 #of Dishwashers 1 Sewer GFC-Residential 6,592.00 #of Gas Fireplace 1 Park Impact Fee 615.00 #of Gas Piping 1 Traffic Impact Fee 900.00 #of Gas Water Heaters 1 Total Calculated: 10,639.60 #of Water Piping 1 Deposits/Receipts: 100.00 #of Hose Bibbs 2 I #of Kitchen Sinks 1 Total Due: 10,539.60 #of Lavatories 2 #of Range Hoods 1 #of Showers 2 #of Ventilation Fans 2 #of Water Closets 2 THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND 0 DINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A RMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STAT 0 LATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. tr2-e Q laa f 1 SIG ATU 0 R AUTHORIZED AGENT I SUED BY CITY OF ANACORTES "AS-BUILT" E Sewer / CONTRACTOR: / /4 ` ' / F. storm PLAT/DIVISION: _4 S/t=S BLOCK LOT ADDRESS: ;3 7/L /S.%� Z o f DATE: %.'—. ,'- D PERMIT# SCALE IV 73 _ STREET ` i A\N i . 7 rl\S\I N i -x-'__ / , �\ ) . (3 Ni ,,r f r u ,,- T., , t „.._..„ 1-, _. , . i_,_____,, , ___. LOCATE STREET(S)ON GRID MAP O�2 Y Off City of Anacortes Permit#: BLD-2006-0283 904 6th Street Issue date: 04/20/2006 `• P.O.Box 547 �,y�, Expire date: 04/20/2007 '9 Uj Anacortes, WA 98221-0547 won Job Address: 3912 COTTAGE PL Permit Type: Foundation Permit ANACORTES WA 98221 Project: APN: Remarks: Install foundation for single family residence unde BLD-2006-0224 per approved plans as noted. Owner: HABITAT CONSTRUCTION Contractor: HABITAT CONSTRUCTION Address: 12940 SUNSET LN Address: 12940 SUNSET LN ANACORTES WA 98221-8525 ANACORTES WA 98221-8525 Phone: (360)293-8215 Phone: (360) 540-8215 License#: HABITC1*969KE General Information: Fees: Building Valuation 10000 Building Permit Fee 80.50 Plan Review Fee 52.33 State Building Code Fee 4.50 Total Calculated: 137.33 Deposits/Receipts: 0.00 Total Due. 137.33 THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, T " .RA r " •F A - RMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STAT. OR Li, AL LAW ;•:. LATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION c ( =rC SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED B Residential Building Permit Application Building Department C P.O. Box 547 Anacortes, WA 98221 Phone No.: 360-293-1901 FAX: 360.293.1938 j SITE ADDRESS: 394.2 C®449.e, Met_ �i..a _ ii:�i,�-`:4Myy}q�e'�.;. .:.df���::i•�"tK '' �i;:., fviA;r ';:;,. ..t , Name A/Alig 'r4 eerfi" Address /`)-9 3/49 c /, f�.s L�'_i City/State/Zip N-tttc[r'tsr-ri) Phone S-40 -51Q-1 S FAX .2 y,3 fl I S State License# fdi9-Q i•Tc%.L F?nap .S-o City of Anacortes License 5S3 7 MagAft0• .,,�..�.,_ 4.,.".:..-:.gAiliganr.,.,.� g v ?�, . t'" :^,4 <s, ti:�r« ., �� , . lt� a-,..- '.i'�C2�''-gym :�:.a;:Q''. �f�.. .. .. '�i.� Name ,5C1/"yt.`e Lo Y- Address City/State/Zip 1'*o*, : 1UATI.ON Phone FAX 2 S9,On, Number of Dwelling Units E-Mail Address Number of Stories _ Building Area: Clairgti3tegt iAeslgner:f7; ugi-jmegr,l ppli syut is,Floor Co s.f 2nd Floor 60 3 s.f. Name be e'b -IP t t5' 1/4—•• 3`d Floor s.f. Basement 351 s.f. Address 414 E 'K..I.?4. I-'- S�- Garage 2'4 /q s.f. Carport s.f. City/State/Zip 4 ida=1J9 Deck ��� s.f. "st- Phone 33C ' 7Ua FAX 5"'-'L- '" =' -11 CD E-mail Address _ ;"n:..�. "•''�l' :: -.ONTO - - .t?{,Aji t .. ... . ,r : y.;, ..y a:,� - - •�r .. �''..�,�'..-,I d ;:��::� :::... . ...:.. �. '. Pit.§t+!! T-F�1?��+}�".i1: �>:;":; ,. .. :�c::�. b , .,.,:..,.. ... .' • '' ///� LENDER INFORMATION MUST BE PROVIDEO�FOROW/MOTS-OVER$5,000 Name Air__ 7InA,'S•---' IN VALUATION PER R`CCW. i j L.! Address Name wL,'S� City/State/Zip Address •-- ' %3 r ��// _ ; Phone S'f6 ��eS FAX 1'- 83/ City/State/Zip i'Yr^e-etrz.44-1 Phone No. .2-9 % 30 0 l� ca tL E-mail Address `7 �,��;, w • 12724 1 CONTINUED ON THE BACKc c /--oaei) zav /o;oacfr Residential Mechanical Fixtures Fuel Type a 3Natural Gas ❑ Electric ❑ Wood 0 Propane Gas ❑ Other Type of Equipment Number of Type of Equipment Number of Fixtures Fixtures Furnace<=100K BTU Clothes Dryer / Boilers/AC/Heat Pump Gas Water Heater Gas Outlets �l Gas Fireplace / t Ventilation Fans % Fireplace Insert Stove,Appliance / Other Units 2 f/t 3 -u Range Hood he Residential Plumbing Fixtures Type of Fixture Number of Type of Fixture Number of Fixtures Fixtures Toilet 3 Clothes Washer / Bathtub / Electric Water Heater Shower 2 Utility Sink Dishwasher / Hose Bibb Hand Sink / Water Piping I Kitchen Sink w/Disposal / Additional Fixtures I HEREBY ACKNOWLEDGE IF HAVE READ THIS PERMIT APPLICANT AND STATE THE INFORMATION IS CORRECT,AND AGREE TO COMPLY WITH ALL CITY ORDINANCES AND STATE LAWS REGULATING ACITIVIES COVERED BY THIS PERMIT APPLICATION. WITH THIS PERMIT ALL CONTRACTORS AND SUBCONTRACTORS SHALL HAVE A CURRENT WASHINGTON STATE CONTRACTORS LICENSE AND A CITY BUSINESS LICENSE. STOP RHEAS LL BE ISSUED ON JOB SITES WHERE CONTRACTORS/SUBCONTRACTORS ARE WORKING WITHOUT PROPE_ APPLICAN SIGNATURE DATE r., rep — I� J LJ • •� 37.8 . I --7 r r1 11 r, I I r LJ 9.0 L.-1LJ L.J deck ir1 _r-1_ r,ZI— di, LTJ LJ L � 72II ' I + 1 J L1 I r I �r,—JLJ I I I 4.7 1 I -...---....„---1 LOT 4 J J 2494 SQ. Ff. r -1J$ I I ---1 r- JI I — i I L--I II 1 L i I I I p I w I 1 0.1 1. I I il -- - I II _J -_ --_I on ____IL I ��L J = -- I B7 L L _J I 9.0 • 378 1a. COTTAGE PLACE "-rth scale: 1" = 10' Erosion will be controlled by existing straw and hydoseeded V area will create bio-filter.Rolled edge of road way will force any runoff to hay waggle and silt fence,CB's have filter socks. 77/ 'SDP , ;�/'/�% / /ei/S // / // j / -- PAnO 1 -9 // / // // /0. ��jj // // / ° ////�/� Addendum to T i/ /' /2/7/// LOT v / �/ �,, r;J // /// ;/;';;//, Revised Final > / / /// --I- 0., /� / ///,//'//%%�/ /�/, ���1 /�j ,,//j; �%% w for clarification '// / ; /%/ // / / C/ . r 6 J.2 / , I //; :', // z j, i 5" SIDEWALK _ rISLE �A'Y / - 1--11 il r—r it 1. ,(� o +/ ,2ST / \\ , m / LOT 13 ‘� I_., LOT 12 U 1', 1 ///� /•`� • �//T 16 302251 7 ' 3166 sf ' LOT 11 EXIST. :•' IPAn. y255, sf POWER Ano1� 1 . �� !! '� \ POLE y , 'Pnno 'O I_ _ - _ Ap, ! - I — L-IOJ ar 1.•: 66__I \ . / h -0. rl6(\\ \ M1`� LOT 14AMP; Q\LOT 10 n 11r T 2794 , 3560 sf 'i . 3617 s I �r ✓. I* ■ - / , �no LOT S W 2ND STREET �.':'PAnOt. taw _ ON// 248s sf /41163 1/ TL //i%ii j/! gj/%! //j // r///'a,/se / . ' _ y 'sr\ `%/ ..., ///7 - a/, , %/• Y�- ri, [fit ' ////si''/ i /i/. ,.. • '- �� I `€ .rw. , l` hI.. I --. i �rw. sw. AJs �,^"...• -O- — i. IT lin- __'' ^I LOT 1 - ' LOT Z�{� 2822 s/f 1`I _i L07 li 2781 5f 3 _ el•6 1. ' LOT 7 -1 a 2670 sf J ;'1 2494 sf -o�,1 - ---_o 2494 sf _c _ 2506 sf 1 _12503 sf'� n 1 i _ .� , n �,, the „ O Lir c . bnl ••uo bhh 0r� 4U 11L. I1 ✓ 5 JZ9 J78 J78 I JIB 78 _ J6.6 PLAT MAP / SCALE I.=20• �'.--------__-" _ _COTTAGE PLACE 5' SIDEWALK _ — I __ SITE' SFf.TI N A-P PL OO.O�r� — 1 Q ".. �zY o Anacortes Planning & Community Development Dept. s Permit Center tppf•w P.O.Box 547,Anacortes,WA 98221-0547 PH(360)293-1901 °��'� Ian Munce,Director • Edwin Frank,Building Official FAX(360)293-1938 April 16, 2006 Habitat Construction 12940 Sunset Lane Anacortes, WA 98221 RE: 3912 Cottage Place The following are comments and questions concerning the plan review done on the above mentioned project. Please revise drawings as necessary. 1. Provide a site plan for each set of drawings and the file. 2. Based on the drawings and the final grades the site the structures are a three story building requiring the $1.00 a square feet fire ladder truck impact fee. 3. Please revise all notes to correspond with current codes IRC, etc. Thank You, CITY OF ANACORTES Don Measamer Senior Plans Examiner DM:md KEYNOTES: ■ J F,16 ATTIC ACCESS to be readily accessible. 22"MINIMUM WIDTH with 30"unobstructed 4. pi N- headroom. Sec. 1505.1. Frame cut access hole to depth of insulation with not less than C i` 20 rn 1/2"plywood.Access cover in garages to be hinged and shall be weather-stripped or ma- 0 - o sealed tight. Q o '2 18 4 :�L' o G.9 SMOKE DETECTOR. Every dwelling unit shall have a smoke detector located in every -0s o WIZ / WV bedroom and at a point centrally located in the corridor or area giving access to each p F M f o separate sleeping area. In new construction,required smoke detectors shall receive their 0m E c� s'-8" I 3"-4" 4F primary power from the building wiring and shall be equipped with a battery backup. Sec. c 4 uu 2-6x4o - sH x-A - --- - C Q 'ZY •-- A 2 310.9.1.4. � S _EGRESS _$ 2-Ox2-0 PIC _ t` 4` r ` ` \\ �\\\\ \\\\\\ ' \\\\\� a \ H.1 EGRESS WINDOW shall have openable section for emergency egress 5.7 square feet & _c c. I A !� min. Minimum net clear openable section to be 20"wide and 24"high. Sill height max. U) 7 Ay . I I - - 44"o f floor. Sec.310.4, , H.2 MECHANICAL FAN. Bathrooms,laundry rooms and the like shall be provided with a CRAWLSPACE a e" w w T mechanical fan connected to the outside capable of 50 c.f.m.and shall not terminate STORAGE / N. b UTILITY ROOM BEDROOM 2 W 2, N closer than 3 feet to any operable window cc opening into the building. Minimum dud WASHER)DRYER 50 WASHER) is 4 inches. UMC 504. 004eN LJ PLUMB FOR fan • H,3 FANS. Dryer, Kitchen,and bath fans to be separately vented to the outside. Sec. al` co rr _ - 9EAM�YBH.OYY'CEILING Q CD ` + �� 1203.3 Install ductwork prior to insulation fro framing inspection. - C o S°s� °yc 0 smoke B� HA EXHAUST FANS to be constructed of smoothbore, noncombustible materials. Approved i 'J 0 In 6-Ox6 8 BYPASS r.." In HW 2-6x6-8 smoke ' a�. .. ` flex connectors not exceeding 6 feet in length maybe used in connection with domestic N N N y i` sc .c`` CLOSET C co O�� 7.��' \ �\ N dryer exhaust. UMC 504.3 0 C c� A \ Ls\\ \\\\\\\\\\\\\\\\\\\\\\\\\\\\`�\\\\\\\ __. \ V O U„ " GARAGE SLAB ` b STOR 2_6x6-8 I 1 H.5 CLOTHES DRYER exhaust ducts shall not exceed a total combined horizontal and - o • MUD 8 sc it 56 dm vertical length of 14 feet, including(2)90 degree elbows. A minimum 4-inch diameter -�- c� ah 2' �� BI Off\ f �" \ exhaust duct of smoothbore, noncombustible materials required with back-draft damper. _ Cy e ,_ I,, � R" p BATH \ UMC504.3 A- cti C . r up tp fret fl 14Rtbs @ 7.5"° i' gi LINEN 1 2-0x6-8 i = p H.10 HOT WATER TANK. Provide pressure relief valve. Drain out, no trapping,end of pipe sc 1 (Ili L' �//l 7/J/O /iy.v aersi 5'-0" •••••;)•• ` N less than 2 feet above ground, pointing down. UPC Sec. 608.5 ` �� \ \ 1 \ -_^.._. - Revision Date $W2 a FOLD 1 1 H.11 HOT WATER TANKS shall be strapped within upper 1/3 and lower 1/3 to prevent w CL 1 �\ overturning in an earthquake. UPC Sec 510.5 (' LL 1 2ac4 FURRING L \ \\\\\\Q�\�t\� • H.12 DISHWASHER.Provide air gap. UPC Sec.807.4 FOR INSULATION \\ \\\\\\\\\\\\\\\\\\\\\\\ .__ .__ ____ _ __ __ _ --�- T -6' / 2 -0",, s'•2" / 1.1 FURNACE installed in garage.Apply gyp.wallboard and fire tape above and behind i 21 2" furnace prior to installation. �, 1.2 A FURNACE supported from the ground shall rest on a concrete slab projecting 3" above adjoining grade.UMC 304.8. Ducts passing through garage floor shall have a 0 minimum of 2 inches of concrete between the duct and Fe ground. j 1.3 No FURNACE shal be installed in any confined space with access only through a N bedroom, bathroom, or closet. UMC 304.5 SEE STRUCTURAL ENGINEERING PACKAGE FOR SHEARWALL SCHEDULE 1.4 Provide at least 30"ofworking space in front offurnace. _ DENOTES SHEARWALL 5 Q - - - - 1,5 COMBUSTION AIR required.UMC Chapter 7. ALL EXTERIOR WALLS, UNLESS NOTED OTHERWISE,ARE SW1 0 Q 1,6 APPLIANCES installed in garages shall be located out of the normal path of vehicles, M () or a means of protection shah be provided, UMC 304.9. Units generating a spade or , flame shall have pilots and burners located 18"min.above the floor.UMC 303.1.3 I.7 METAL DUCTS shall not be installed within 4"of the ground. UMC 603.2.2 1.8 When metal DUCTS are installed in or under concrete slabs, they shall be encased in at least 2"olc concrete. UMC 603.1 d) L.1 GARAGE AND HOUSE occupancy separation to be 5/8"type X G.W.B. on garage party C' wall and bearing walls, posts and beams supporting floors or roofs above,and 5/8"type X Q z - G.W.B.on ceiling.Sec 302.4. All holes through the wallboard to be sealed with approved r---. Ii9€10 materials. HOLD DOWN SCHEDULE p BUILDING INFORMATION CC 51 L.2 BETWEEN GARAGE AND HOUSE doors to be min. 1318"solid core with self-dosing 7- c 0 HOLD DOWN/POST POST TO SHTG. 1. MK. SIMPSON MODEL # HOLD DOWN TYPE POST SIZE NAILING NAIUNG CAPACITY 1 device. There shall be no openings in wall between garage and any room used for a, JO PLAN NAME : CATALA - REVERSED PLAN ch IF STUD TO STUD 16-10d x 1Y2' 8d © 6" O,C. sleeping.Sec.302.4. Two spring hinges are required. 2: .2 LL_ AREAS: MSTI36 CENTER ON RIM BOARD DOUBLE 2x 8 EA END EA. 2x POST 1260 LB JI , t/) L,3 FLOOR SURFACE in garage/carport to be noncombustible or asphaltic.Sec. 312.5. co c� Z MAIN FLOOR = 694 Sq. Ft. �� MSTI48 STUD TO UD CENTER ON RIMBOARD DOUBLE 2x 14 EAd END 1 EA.d C2x6POST 2205 LB IIIg you W cd W L.4 CONCRETE PORCH,walkway,steps,or landings shall not be poured against wood J u�ll CONS UPPER FLOOR = 407 Sq. Ft. STUD TO STUD 68-16d SINKERS 8d @ 4" 0.c. framing. .4-, W BONUS ROOM = 196 Sq. Ft. ® MSTC66 CENTER ON RIM BOARD DOUBLE 2x 34 EA END EA. 2x POST 5075 LB w U) Q N.1 WHOLE HOUSE FANS shall have a manual control and automatic control,such as a = N BASEMENT - HEATED & FINISHED AREA = 351 Sq. Ft. Q STHD10 CONCRETE TO STUD WALL DOUBLE 2x 28-16d SINKERS ad @ s" 0.C. i dock timer with a zone rating of 1.5 or less. Li j I-- Q CO EA. 2x POST 2990 LB r ' TOTAL FINISHED & HEATED AREA = 1648 Sq. Ft. CONCRETE TO STUD WALL 8d @ 6" O,C. I !1 NA DOORS. where outdoor air supplies are separated from exhaust points by doors, -.C?© STHDIORJ with RIM BOARD DOUBLE 2x 28-16d SINKERS EA. 2x POST 2990 LB 1 ; provisions shall be made to insure air flow by undercutting doors or installation of grilles DRAWN: SLG BASEMENT - UNHEATED & UNFINISHED AREA = 124 S Ft. 8d @ 4" O,C. �' 314*minimum, q STHD14 CONCRETE TO STUD WALL DOUBLE 2x 38-16d SINKERS 4160 L8 EA. 2x POST 4 MARCH 30, 06 PORCHES & DECKS : Q SSTBL28 ANCHOR CONCRETE TO STUD WALL 4x POST 24-SDS Yn'x3' III @)3ROOWC 8d 6295 LB a II 1'I SCALE: 1/4" - 1' 0" PHD8 SDS3 W (2 w1 1 41114i t :,n°du�t�Nl)j1)l)))N)l�))))1))))H'I�> � j wassulA n, u,�� 1' ' d r - rx. : Ii�U' " 4 �I'�xA _, w: ,hiaggI �m iltili 16111 ,1 hl. �j VIEW SIDE = 200 Sq. Ft. FRONT PATIO = 54 Sq. Ft. NOTES: 1. INSTALL ON SIDE OPPOSIT OF SHEATHING or OVER SHEATHING SHEET 2. BEGIN NAILING AT PLATE AND WORK OUT. ze. SEE STRUCTURAL ENGINEERING FOR ADDITIONAL NOTES AND DETAILS. Basement Floor Plan Al scale: 1/4" = 1P-0"