HomeMy WebLinkAboutPermit File BLD-2019-0452 4208 Osprey Lane (2)4" Concrete Slab over 6 mil
vapor barrier on 2" gravel bed
1' - 0"18' - 0"16' - 0"7' - 0"5' - 0"
1
A501
1
A501
1
A500
2
A500
continuous footing4
A501
slope slab 2% for positive drainage
1
2
4
6
ABCE
A1
B1
6a
3
120.00°2' - 8"19' - 0 1/2"1' - 0"8' - 0"1' - 0"7' - 0"1' - 0"5
3 ' - 1 0 1 /2 "b lo c k o u t fo r g a ra g e d o o r o p e n in g
1 6 ' - 3 "2 4 ' - 0 "9'
-
4 3/4"
3' - 0"
F3 5 "2 4 ' - 1 0 "12' - 0"2' - 0"1' - 2 3/4"10' - 9 1/4"8' - 0"8' - 0"8' - 0"9' - 3"13' - 2 1/4"
5' - 2 1/4"8' - 0"9' - 8 1/2"11' - 7 1/2"crawl space control joint 21'
-
4 1/2"
120.00°
A500
3
4
A500
4
A500
5
A500
66" max spacing
1' - 10 1/4"A500
7
A500
85' - 0"14' - 2 3/4"
0"33' - 3"
crawl space grade lines proposed -
may change per site conditions
9
A500
step in stem wall
24"x24"x8" thick footing
w/ (2) #4's each way -(3) at location
A500
10
stepped footing/stem wall -
site/grade dependent
4
A501
4
A501
retaining walls
retaining walls 4' - 2 1/4"7
pier 30 pier 30
Pier 18 6' - 2"5' - 10 1/2"9' - 6"
D
to framing10' - 0"8' - 7 1/2"(2) stud column
8946#
1453#
7493#
4887 4887#
pier 30
HDU2
HDU2
HDU2
HDU8
HDU8
HDU4
HDU4
18" wide x 18"
deep thickened
slab grade beam
18" wide x 12"
deep thickened
slab grade beam
control joint -typ.
12 ft spacing
4" Concrete Slab over 6 mil
vapor barrier on 2" gravel bed
at daylight basement
17' - 9"
HDU2 HDU2
HDU4
HDU2
HDU2
HDU2
HDU2
HDU4
HDU2
HDU2
HDU2
HDU2
HDU4HDU2
HDU2
HDU2 HDU2
HDU2
HDU2
HDU2 HDU21' - 6"1' - 6"2' - 0"1' - 6"2
A501
HDU4
HDU4
HDU2
HDU4
41' - 0"10' - 0"28' - 6 1/2"37' - 8 65/256"
HDU2 HDU2 HDU2 HDU2
4" Concrete Slab over 6 mil
vapor barrier on 2" gravel bed
at daylight basement
control joint -typ.
12 ft spacing
12'
-
0"
8 "8 "4
A501
4
A501 4
A501
4
A501
4
A501
2
A501
Foundation Plan Notes:
1. Coordinate w/ mechanical and
electrical for locations and sizes of
foundation / slab block-outs.
2. Fasteners: metal elements
including, connectors, must use hot-
dipped galvanized metal when in
contact with ACZA pressure treated
materials. [r319.3] -see 37/sp1
3. Trusses: all concentrated loads
from roof trusses must be
transferred to the foundation with a
built-up post and footing as required.
Verify locations with truss engineer.
4. See Lateral Sheets A3.2 and
A3.3 for holdown locations.
3. Provide blocking between i-joists at
interior bearing locations where there is
a load bearing wall above.
4. Provide timberstrand rims where
floor joists bear at exterior walls.
5. Connections: Simpson Company or
eq.
Fasteners:
Metal elements, including connectors,
must use hot-dipped galvanized metal
when in contact with ACZA pressure
treated materials. [r319.3] -see 37/sp1
Floor framing notes:
Layout shown here is for schematic
design only. Manufacturer shall
provide and submit engineered design
to the building department for approval
prior to fabrication and installation.
All joist to joist and joist to beam
connectors to be designed by truss
manufacturer.
Floor sheathing:
1. Use 3/4" cdx or OSB Sturdi-floor
T&G, glue and nail w/ ring shank 8d's
at 6" at edges and 12" in the field.
Face grain perpendicular to supports.
2. Provide sold blocking in the joist
cavity beneath all post locations and
between upper and lower studs at floor
to floor holdown locations.
HDU2-SDS2.4 6-SDS 1/4 x 2 1/2" screws, 5/8" bolt, 3" min wood thickness, [3075 #]
HDU2-SDS2.5 6-SDS 1/4 x 2 1/2" screws, 3" min wood thickness, SB5/8x24 bolt, 18" embed. [3075 #]
HDU4-SDS2.5 10-SDS 1/4 x 2 1/2" screws, 3" min wood thickness, SB5/8x24 bolt, 18" embed. [4565 #]
HDU5-SDS2.5 14-SDS 1/4 x 2 1/2" screws, 3" min wood thickness, SB5/8x24 bolt, 18" embed. [5645 #]
HDU8-SDS2.5 20-SDS 1/4 x 2 1/2" screws, 3.5" min wood thickness, PAB7-18 bolt, 15" embed. [6970 #]
HDU11-SDS2.5 30-SDS 1/4 x 2 1/2" screws, 5.5" min wood thickness, PAB8-18 bolt, 15" embed. [9535 #]
HDU14-SDS2.5 36-SDS 1/4 x 2 1/2" screws, 4x6 min wood thickness, PAB8-18 bolt, 15" embed. [10,770 #]
HDU14-SDS2.5 (6X6)36-SDS 1/4 x 2 1/2" screws, 6x6 min wood thickness, PAB8-24 bolt, 21" embed. [14,445 #]
MST37 14-16d's -double stud to double stud [2465 #]
MST48 32-16d's -double stud to double stud [3960 #]
MST60 40-16d's -double stud to double stud [6235 #]
ST6224 28-16d's -double stud above [2540 #]
Issue Date:
Project:
1005 4th Street
anacortes, washington 98221
360.588.0471
mike underwood, AIA
mike@underwoodarchitecture.com
Project name:
Project Address:
Registered
ARCHITECT
9878
Michael G. Underwood
State of Washington
9-22-21
C:\Users\Admin\revit local files\Stout Lot 3 - 3 storyv4_mike@underwoodarchitecture.com.rvt9/28/2020 11:02:08 AM
A104
Foundation
Plan
1/27/2020
Stout Lot 3
Stout Lot 3
Residence
Permit Set
4208 Osprey Ln
1/4" = 1'-0"1 level 0 - Foundation Plan
1/4" = 1'-0"
Holdown Schedule
Revisions
No. Date Description
3/4" T&G plywood -glue & nail
to supporting members
Manufacturered I-joist see
plan (see plan for direction),
R30 insulation
5/8"X10" anchor bolts, embedded 7" into
concrete, at 4'-0"o.c. u.n.o., and set between 3
1/2" AND 12" from board ends with 3" X 3" X
1/4" thick washers. Min. (2) A.B.'S per board
[R403.1.6.1] Use galvanized washers or provide
an isolator gasket between washer and sill
plate.
15# building paper
or vapor barrier
slab per plan
12" wide drain rock
2 coats of asphalt emulsion brush
or spray applied per manufactures
recommendations
compacted fill
rigid insulation
grade
5 1/2"
1"
2x4 studs at 16" o.c.
R15 insulation
1/2" g.w.b.
2x4 p.t. sill
DB E
2" clr typ. -where fill against
wall is less than 5'-0" high -
place reinf. @ wall
centerline
Rh
A4" perf drain pipe to
building exterior
C
Rv
garage
4" concrete slab over 6 mil vapor
barrier on 2" gravel bed
2" R-10 rigid insulation
expansion felt
isolate w/ 30# felt
18"h s.s. flashing extended
below top of stem
3/4" T&G plywood -glue & nail
to supporting members
Manufacturered I-joist see
plan (see plan for direction),
R30 insulation
5/8"X10" anchor bolts, embedded 7" into
concrete, at 4'-0"o.c. u.n.o., and set between 3
1/2" AND 12" from board ends with 3" X 3" X
1/4" thick washers. Min. (2) A.B.'S per board
[R403.1.6.1] Use galvanized washers or provide
an isolator gasket between washer and sill
plate.
15# building paper
or vapor barrier
slab per plan
12" wide drain rock
2 coats of asphalt emulsion brush
or spray applied per manufactures
recommendations
compacted fill
rigid insulation
grade
5 1/2"
1"
2x4 studs at 16" o.c.
R15 insulation
1/2" g.w.b.
2x4 p.t. sill
DB E
2" clr typ. -where fill against
wall is less than 5'-0" high -
place reinf. @ wall
centerline
Rh
A4" perf drain pipe to
building exterior
Rv
wall framing
wall sheathing
4"h self-adhering
membrane over flashing
metal flashing
2x4 cedar ripped
saw kerf 1/8" deep drip edge
5/4x10 cedar
sealant
siding1"1/2"1 1/4"
house wrap
1x6 cedar
1/4 trim
'z' Flashing
As Req'd
3"3/4"8" strip of vycor wrap over
window flange
8" strip of vycor wrap over 'z'
flashing
typ. window and casing
8" strip of vycor wrap
each side
8" strip of vycor wrap
over rough sill
Install building wrap per manufacturer’s
instructions.
Install window per manufacturer’s
recommendations.
Caulk all windows to sheathing joints
with flexible butyl caulk.
Install siding and window trim. Install
metal "z" flashing over top of trim.
Caulk top and side trim to window frame
and siding.
Follow Grace Vycor self-adhearing
flashing application instructions for
weather resistive barrier installation.
Elevation8"8"8"sealant
siding
4"h self-adhering
membrane over flashing
metal flashing
sealant
4" concrete slab over 6 mil vapor
barrier on 2" gravel bed
1/2" type x GWB
lower floor slab floor
where occours AB E
C D30 dia.Rbend
Rh
Rv
Rft
2" min.
A B C D E Rft Rh Rv Rbend
unbalanced
height
wall
offset
footing
width
footing
height
wall
thickness
footing
continuous
horizontal
rebar
vertical
rebar
length of
bent bar base
0' to 4'centered 18"6"8"(3) #4 #4 @ 24" oc 6"#4 @ 24" oc
4'-1" to 6'5"36"8"8"(3) #4 #4 @ 24" oc 6"#4 @ 18" oc
6'-1" to 8'8"48"12"8"(4) #5 #5 @ 18" oc 8"#5 @ 12" oc
8'-1" to 10'8"60"12"8"(6) #5 #5 @ 18" oc 12"#5 @ 9" oc
4" concrete slab over 6 mil vapor barrier
on 2" rigid insulation and / or gravel
1/2" type x GWB
AB E
C DRbend
Rft2' - 0"2' - 0"
Issue Date:
Project:
1005 4th Street
anacortes, washington 98221
360.588.0471
mike underwood, AIA
mike@underwoodarchitecture.com
Project name:
Project Address:
Registered
ARCHITECT
9878
Michael G. Underwood
State of Washington
9-22-21
C:\Users\Admin\revit local files\Stout Lot 3 - 3 storyv4_mike@underwoodarchitecture.com.rvt9/28/2020 11:02:25 AM
A501
Details
1/27/2020
Stout Lot 3
Stout Lot 3
Residence
Permit Set
4208 Osprey Ln
3/4" = 1'-0"2 fndn at retaining - mid. residence
3/4" = 1'-0"1 Residence at Garage Detail
1 1/2" = 1'-0"3 watertable detail
1" = 1'-0"5 Window Flashing
1 1/2" = 1'-0"6 Window Trim Detail
3/4" = 1'-0"7 Retaining Wall Dimensions
3/4" = 1'-0"4 Level 0 foundation
Revisions
No. Date Description
PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT
RESUBMITTAL/ PLAN REVISION /ADDITIONAL INFO COVER SHEET
Mailing Address: P.O. Box 547, Anacortes, WA 98221
Office Location: 904 6th Street, Anacortes WA 98821
Phone: (360) 299-1984
Please use this form to submit revisions or additional information to your permit application.
Permit /Project #: _________________________________ Date: ____________________________________
Project Name: ___________________________________ Project Address: ___________________________
Project Contact: __________________________________ Company Name: ___________________________
Contact Phone: ____________________________ Contact Email: ___________________________________
Has the permit been issued yet? Yes No
All revisions must be either clouded or highlighted & wet stamped by an architect/ engineer (if applicable).
Has this been done? Yes No
What department(s) is this resubmittal/ revision /additional information to go to?
Planning Dept. Building Dept. Fire Dept. Stormwater Public Works Dept.
Is the plan revision or additional information, in r esponse to a plan review letter?
Yes. A copy of the plan review letter with itemized responses to each item is required.
No, the revision or additional information is initiated by the applicant, landowner, designer, or builder.
If not in response to a Plan Review Letter, please explain the nature of the revisions and/or additional info:
Are you submitting a full replacement? Yes No If not what page # is being replaced? _________
Two full sized copies of all revised /additional information is required. Has this been done? Yes No
Two 11” X 17” reduced copies of revised site or floor plan is required. Has this been done? Yes No
Check the box next to the type of plan, report, or calculation where revisions or additional
information can be found.
Site Plan Building Plans Structural Plan
Landscape Plan Parking Plan Tree Preservation Plan
Arborist Report SEPA checklist Wetland Report
Geotechnical Report Storm Drainage Analysis TESC Plan
Civil Plan Lot Coverage Calculations Impervious Surface Calculations
FAR Calculations Grading Plan Survey (Boundary /Topo)
Mechanical Plan Plumbing Plan Other: _____________________
FOR OFFICE USE ONLY:
ROUTED: ROUTED TO: DATE
ROUTED: APPROVED BY: DATE
APPROVED:
Building Dept.
Planning Dept.
Stormwater
Public Works Dept.
Fire Dept.
Third Party Review