Loading...
HomeMy WebLinkAboutPermit File 508 4th StreetPROJECT DATAABBREVIATIONSGENERAL NOTES SYMBOLS @ C d 0# AB AC A/C ALUM ANOD BD BLDG BLK(G) BN BOT CB CI CJ CL CLG CLR CMU CO COL CONT CSK DF DIA DN DS DWG DWR D/W E (E) EA EJ ELEV EN EQ EQUIP FAU FBO FD FE(C) FF FG FH FIN FL FLG FLR FN FOC FOF FOM FOP FOS FT GA GALV GYP HB HP HR HTR HVAC HW (R) AT CENTER LINE PENNY POUND PERPENDICULAR ANGLE ANCHOR BOLT ASPHALTIC CONCRETE AIR CONDITIONING ALUMINUM ANODIZED BOARD BUILDING BLOCK(ING) BOUNDARY NAILING BOTTOM CATCH BASIN CAST IRON CEILING JOIST CLOSET CEILING CLEAR CONCRETE MASONRY UNIT CLEAN OUT COLUMN CONTINUOUS COUNTERSINK DOUGLAS FIR DIAMETER DOWN DOWNSPOUT DRAWING DRAWER DISHWASHER EAST EXISTING EACH EXPANSION JOINT ELEVATION EDGE NAIL EQUAL EQUIPMENT FORCED AIR UNIT FURNISHED BY OWNER OR OTHERS, TO BE INSTALLED BY CONTRACTOR FLOOR DRAIN FIRE EXITING. (+ CABINET) FINISHED FLOOR FINISHED GRADE FLAT HEAD FINISH FLOW LEVEL FLASHING FLOOR FIELD NAILING FACE OF CONCRETE FACE OF FINISH FACE OF MASONRY FACE OF PLYWOOD FACE OF STUD FOOT OR FEET GAUGE GALVANIZED GYPSUM HOSE BIBB HORSE POWER HOUR HEATER HEATING/VENTILATING/ A/C HOT WATER (RTRN) INV LAM LAV LB LT MAS MATL MAX MB MECH MEMB MTL MFR MIN MISC N (N) NO / # NTS OC OH OPNG PL PLAM PLAS PLYWD P PR PT RD RH RM RO RWD S.A.M.U. SCHED S SHTNG SIM SMACNA SPEC SQ SSTL STD STL TC TOC TCB T&G TP TOW TYP UNO VERT VGDF VTR W WC WH WP WS WWF W/ WO W/O POC TBS INVERT LAMINATE(D) LAVATORY LAG BOLT LIGHT MASONRY MATERIAL MAXIMUM MACHINE BOLT MECHANICAL MEMBRANE METAL MANUFACTURER MINIMUM MISCELLANEOUS NORTH NEW NUMBER NOT TO SCALE ON CENTER OVAL HEAD OR OVER HEAD OPENING PLATE OR PROP. LINE PLASTIC LAMINATE PLASTER PLYWOOD PAINT (NUMBER - SEE SPECS) PAIR PRESSURE-TREATED ROOF DRAIN ROUND HEAD ROOM ROUGH OPENING REDWOOD SELF-ADHERING MEMBRANE UNDERLAYMENT SCHEDULE(D) SOUTH SHEATHING SIMILAR RE: THE ARCH SHEET METAL MANUAL SPECIFICATION SQUARE STAINLESS STEEL STANDARD STEEL TOP OF CURB OR TOP OF CONCRETE TOP OF CATCH BASIN TONGUE & GROOVE TOP OF PAVING TOP OF WALL TYPICAL UNLESS NOTED OTHERWISE VERTICAL GRAIN DOUGLAS FIR VENT THRU ROOF WEST WATER CLOSET WATER HEATER WATERPROOF WOOD SCREW OR WATER SOFTENER WELDED WIRE FABRIC WITH WALL OVEN WITHOUT POINT OF CONNECTION TO BE SELECTED L CONSTRUCTION TYPE: LOT # ZONE: PROJECT ADDRESS: OWNER: P56508 TYPE V-B (IBC) CLARITY MILLER MS A. GENERAL NOTES 1. INTERPRETATION OF DRAWINGS AND DOCUMENTS: EACH CONTRACTOR / SUB-CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT THE PROJECT SITE BEFORE EXECUTING ANY WORK AND SHALL NOTIFY THE OWNER/BUILDER AND THE DESIGNER OF ANY DISCREPANCIES BEFORE PROCEEDING. THE DESIGNER SHALL BE NOTIFIED OF ANY UNUSUAL OR UNFORESEEN CONDITIONS OR SITUATIONS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OR SAFETY OF THE PROJECT. 2. ADHERENCE TO PLANS: STRICT ADHERENCE TO THE CONSTRUCTION DOCUMENTS MUST BE MAINTAINED. NO CHANGES SHALL BE MADE IN THE PROJECT WHICH DEVIATE FROM THE PLANS AND SPECIFICATIONS WITHOUT THE WRITTEN CONSENT OF THE OWNER OR DESIGNER. NO STRUCTURAL CHANGES SHALL BE MADE WITHOUT THE WRITTEN CONSENT OF THE DESIGNER AND STRUCTURAL ENGINEER. 3. WORKING DRAWING: FIGURED DIMENSIONS AND DETAILED DRAWINGS SHALL BE FOLLOWED IN PREFERENCE TO SCALE MEASUREMENTS. IN CASE OF ANY DOUBT ON THE PART OF THE CONTRACTOR AS TO THE EXACT MEANING OF THE DRAWINGS AND THESE SPECIFICATIONS, HE SHALL APPLY TO THE DESIGNER OR OWNER FOR AN INTERPRETATION BEFORE PROCEEDING WITH HIS WORK. 4. SHOP DRAWINGS: CONTRACTORS SHALL SUBMIT COPIES OF ALL SHOP DRAWINGS FOR REVIEW BY DESIGNER AND OWNER/BUILDER PRIOR TO CONTRACTOR'S APPROVAL FOR CONSTRUCTION. 5. CONTRACTORS SHALL PROVIDE ALL SHORING AND BRACING REQUIRED AND TO INSURE SAFETY OF THE PROJECT WORK. 6. WHEREVER IN THESE DRAWINGS ANY MATERIAL OR PROCESS IS INDICATED, IT IS FOR THE PURPOSE OF FACILITATING DESCRIPTION OF THE MATERIAL OR PROCESS DESIRED. CONTRACTORS MAY OFFER ANY MATERIAL OR PROCESS WHICH SHALL BE DEEMED EQUIVALENT BY THE ENGINEER AND THE DESIGNER TO THAT MATERIAL OR PROCESS INDICATED OR SPECIFIED. 7. UNLESS OTHERWISE SPECIFIED, ALL MATERIALS SHALL BE NEW AND BOTH WORKMANSHIP AND MATERIALS SHALL BE THE BEST OF THEIR RESPECTIVE KINDS. CONTRACTORS SHALL, IF REQUIRED, FURNISH SATISFACTORY EVIDENCE AS THE KIND AND QUALITY OF MATERIALS. 8. IT SHALL BE THE DUTY OF EACH SUBCONTRACTOR TO REVIEW AND TO BE FULLY INFORMED WITH REGARD TO THE GENERAL CONDITIONS AND CONSTRUCTION DOCUMENTS, INCLUDING SPECIFICATIONS. 9. NOTES IN DETAILS AND DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES, TYPICAL DETAILS, AND SPECIFICATIONS. B. PERMITS AND REGULATIONS 1. THE CONTRACTOR SHALL PAY FOR AND OBTAIN ALL PERMITS REQUIRED BY LOCAL AUTHORITIES BEFORE PROCEEDING WITH HIS RESPECTIVE INSTALLATION AND SHALL ARRANGE AND PAY FOR ANY INSPECTIONS AND EXAMINATIONS REQUIRED BY THOSE AUTHORITIES. 2. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE CURRENT EDITION OF THE INTERNATIONAL BUILDING CODE, ALL CBC AMENDMENTS AND ADDITIONS, AND LAWS, ORDINANCES AND REGULATIONS OF ALL GOVERNMENTAL BODIES WITH JURISDICTION OVER THE PROJECT. 3. IF THE DRAWINGS AND SPECIFICATIONS ARE AT VARIANCE WITH ANY FEDERAL, STATE AND LOCAL OR MUNICIPAL LAW, ORDINANCE, RULES OR DEPARTMENTAL REGULATIONS, THE CONTRACTOR SHALL NOTIFY THE DESIGNER AND OWNER/BUILDER IN WRITING BEFORE PROCEEDING WITH THAT WORK. IF ANY OF THE CONTRACTOR'S WORK SHALL BE DONE CONTRARY THERETO WITHOUT SUCH NOTICE HE SHALL BEAR ALL COST ARISING THEREFROM. C. PROTECTION OF WORK & PROPERTY 1. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ALL VIOLATIONS OF CITY ORDINANCES AND STATE LAWS INVOLVED IN THE PERFORMANCE OF HIS WORK. HE SHALL PROVIDE, DURING THE PROGRESS OF HIS WORK, EVERY AND ALL SAFEGUARDS AND PROTECTION AGAINST ACCIDENTS, INJURY AND DAMAGE TO PERSONS AND PROPERTY INCLUDING ADJOINING PROPERTY. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK AND EVERY PART THEREOF, AND FOR ALL MATERIALS, TOOLS, APPLIANCES AND PROPERTY OF EVERY DESCRIPTION USED IN CONNECTION THEREWITH. 2. EACH CONTRACTOR / SUB-CONTRACTOR ASSUMES ALL RISKS, HAZARDS AND CONDITIONS IN CONNECTION WITH THE PERFORMANCE OF THE CONTRACT, AND EVEN IF THE PERFORMANCE OF THE CONTRACT INVOLVES A GREATER EXPENDITURE OF MONEY THAN THE CONTRACTOR EXPECTED AT THE TIME OF BIDDING, NO ALLOWANCE WILL BE MADE ON ACCOUNT THEREOF, AND THE CONTRACTOR SHALL CONTINUE WITH AND COMPLETE THE WORK. D. SUPERVISION 1. EACH CONTRACTOR SHALL GIVE PERSONAL SUPERVISION TO THE WORK, USING HIS BEST SKILL AND ATTENTION, AND SHALL KEEP A COMPETENT FOREMAN AND NECESSARY ASSISTANTS CONSTANTLY ON THE SITE. THE FOREMAN SHALL BE THE PERSONAL REPRESENTATIVE OF THE CONTRACTOR AND ALL DIRECTIONS GIVEN BY HIM SHALL BE AS BINDING AS IF DELIVERED TO THE CONTRACTOR. A FLUENT ENGLISH SPEAKING SUPERVISOR IS TO BE PRESENT AT ALL TIMES. E. DAMAGES IN THE WORK 1. THE OWNER, WITHOUT INVALIDATING THE CONTRACT, MAY ALTER BY ADDING TO OR DEDUCTING FROM THE WORK COVERED IN THE CONTRACT. ALL SUCH WORK SHALL BE EXECUTED UNDER THE CONDITIONS OF THE ORIGINAL CONTRACT EXCEPT THAT NO EXTRA WORK OR CHANGES SHALL BE DONE WITHOUT WRITTEN ORDER FROM THE DESIGNER OR OWNER. SUCH ORDERS SHALL COVER THE AGREED PRICE AND TERMS OF EXTRA WORK OF CHANGES, IF WORK IS TO BE OMITTED, THEN PROPER CREDIT FOR SUCH OMITTED WORK SHALL BE GIVEN THE OWNER. F. CLEANING BUILDING AND PREMISES 1. PRIOR TO THE COMPLETION OF THE WORK, EACH CONTRACTOR / SUB-CONTRACTOR SHALL THOROUGHLY CLEAN THE SITE WITH RESPECT TO MATERIALS AND WASTE ASSOCIATE WITH THE COMPLETION OF THEIR WORK. EACH CONTRACTOR SHALL DO THEIR BEST TO KEEP A CLEAN AND SAFE SITE DURING THE PERFORMANCE OF THEIR WORK. EACH CONTRACTOR WILL MAKE EFFORTS TO RESPONSIBLY DISPOSE OF WASTE IN THE APPROPRIATE RECYCLE OR WASTE RECEPTICALS. G. GUARANTEES 1. EXCEPT AS OTHERWISE SPECIFIED, ALL WORK SHALL BE GUARANTEED IN WRITING BY EACH CONTRACTOR AGAINST DEFECTS RESULTING FROM DEFECTIVE MATERIALS, POOR WORKMANSHIP OR FAULTY EQUIPMENT, FOR A PERIOD OF ONE YEAR FROM THE DATE OF FILING THE NOTICE OF COMPLETION AND THE ACCEPTANCE OF THE BUILDING BY THE OWNER. IF WITHIN THE GUARANTEE PERIOD CORRECTION OF FAULTY MATERIALS OR WORKMANSHIP IS NECESSARY IN THE OPINION OF THE OWNER, THE CONTRACTOR SHALL PROMPTLY, UPON RECEIPT OF NOTICE FROM THE OWNER AND WITHOUT EXPENSE TO THE OWNER, CORRECT FAULTY MATERIALS OR WORKMANSHIP. H. VERIFICATION OF UNDERGROUND UTILITY IMPROVEMENTS 1. EACH SUB-CONTRACTOR SHALL VERIFY WITH THE GENERAL CONTRACTOR THAT EXISTING UNDERGROUND UTILITY LOCATIONS HAVE BEEN IDENTIFIED AND LOCATED BEFORE COMMENCING WITH ANY SUB-GRADE WORK. I. RESERVED J. COORDINATION 1. EACH SUB-CONTRACTOR IS REQUIRED TO CONDUCT A PRE-CONSTRUCTION MEETING WITH THE GENERAL CONTRACTOR PRIOR TO STARTING WORK. THIS MEETING SHOULD OCCUR NO SOONER THAN 72 HOURS PRIOR TO STARTING WORK. 2. CONCRETE CONTRACTOR IS TO COORDINATE ALL REQUIRED BLOCK-OUTS, UNDER-SLAB PIPING/VENTING OR CONDUIT, AND ANY IN-SLAB ELEMENTS REQUIRED PRIOR TO POURING THE PERTINENT PORTION OF CONCRETE. 3. SHOP DRAWINGS SHALL BE PROVIDED FOR ALL STEEL WORK, MILLWORK, AND SPECIAL TIMBER CONNECTIONS K. TOLERANCES ALL WORK PLACED SHALL BE LEVEL, PLUMB, AND IN PROPER ALIGNMENT. FOR PRIMARY CONSTRUCTION SYSTEMS THE FOLLOWING TOLERANCES SHALL BE MET: UNLESS NOTED OTHERWISE, DEVIATION FROM PLUMB, LEVEL, & PROPER ALIGNMENT SHALL NOT EXCEED 1/4" IN 10'. 508 4TH STREET ANACORTES, WA 98221 BUILDING DEPARTMENT CODES SHEET NUMBER) SHEET NUMBER) SHEET NUMBER) SHEET NUMBER) WALL TYPE KEY D C A B A#.# - 1 A#.# 1 A#.# 1 A#.# 1 A#.# INTERIOR ELEVATION SECTION REFERENCE (DRAWING NUMBER, ELEVATION REFERENCE (DRAWING NUMBER, DETAIL REFERENCES (DRAWING NUMBER, (DRAWING NUMBER, KEYNOTE REVISION 0" 0" 1 0 M 0 P 0 1 EXT-00 000 ROOM NAME REFERENCE, EQUIPMENT ROOM NAME / NUMBER EXISTING GRADE MARKER REFERENCE, MECH. EQUIP. REFERENCE, PLUMBING FIXT. MATERIAL NOTE NEW GRADE MARKER A PROJECT DESCRIPTION A NEW DETACHED ACCESSORY DWELLNG UNIT, CONNECTION TO UTILITIES (WATER, SEWER, GAS), REAR YARD LANDSCAPING. ALL NEW WORK SHALL COMPLY WITH: --2015 INTERNATIONAL RESIDENTIAL CODE (IRC) --2015 INTERNATIONAL MECHANICAL CODE (IMC) --2015 INTERNATIONAL FIRE CODE (IFC) --2015 INTERNATIONAL PLUMBING CODE (IPC) --2015 WASHINGTON STATE ENERGY CODE --2020 ANACORTES UNIFIED DEVELOPMENT CODE CITY OF ANACORTES PLANNING & DEVELOPMENT FIRE DEPARTMENT INSPECTION SUMMARY PER CITY OF ANACORTES BUILDING AND PLANNING DEPARTMENT & WA STATE L&I (ELECTRICAL), NO SPECIAL INSPECTIONS REQUIRED 508 4TH STREET ANACORTES, WA 98221 DETACHED ACCESSORY DWELLING UNIT 508 4TH STREET ANACORTES, WA FRONT YARD REAR YARD SIDE YARD PROVIDED 25FT FOR DETACHED ADU (ROOF PITCH OF 6:12 OR GREATER) SET BACKS HEIGHT LIMIT REQUIRED 10'-0"NA 0'-0" (OFF ALLEYWAY)5'-0" CITY OF ANACORTES 10'-0" MIN.6'-0" AND 35'-9.5" 000 DOOR & WINDOW # TITLE SHEET T001 DRAWING INDEX XISSUE REVISIONORIGINAL ISSUE SHEET NUMBER FROM SET REMOVED SHEET TITLE XX"STEP SYMBOL (STEP IN FINISHED BUILDING CEILING) PROJECT DATA (CONT.) PERMIT SUBMITTAL ISSUED FOR PERMITDESCRIPTIONDATE COPYRIGHT MOA Architects PC, 2020 All ideas, designs, and plans indicated or represented by these drawings are owned by and are property of Mobile Office Architects PC (MOA) and were created and developed as instruments of service in connection with the specified project. None of such ideas, designs, or plans shall be used for any purpose whatsoever without the written permission of MOA. ARCHITECT MOA DESIGN-BUILD DUSTIN STEPHENS, RA LIC. # 11451 805 722-9083 DSTEPHENS@MO-ARCH.COM OWNER CLARITY MILLER 508 4TH STREET ANACORTES, WA 98221 CLARITYMILLERGOE@GMAIL.COM c MILLER / GOE DETATCHED ADU 508 4TH STREET, ANACORTES, WA 98221 APN P56508 07/13/20 ISSUED FOR PERMIT SEAL & SIGNATURE: T001 TITLE SHEET ARCHITECTURAL: A100 SITE PLAN W/ STORMWATER REQUIREMENTS A200 BUILDING ELEVATIONS 2 UNCOVERED PROVIDED, STREET PARKING AVAILABLE DIRECTLY PARKING STORMWATER REQUIREMENTS PER CITY OF ANACORTES FIGURE I 2.4.2 FLOW CHART: PROJECT SCOPE INCLUDES LESS THAN 2,000 SQFT OF NEW IMPERVIOUS AREA, INCLUDING HARDSCAPE; AND INCLUDES LESS THAN 7,000 SQFT OF TOTAL LAND DISTURBING ACTIVITY----------------------- MINIMUM REQUIREMENT #2 APPLIES A301 CONSTRUCTION SECTIONS STRUCTURAL: S100 STRUCTURAL NOTES S101 FOUNDATION & FRAMING PLANS A101 CONSTRUCTION PLANS A300 CONSTRUCTION SECTIONS T002 ENERGY CODE NOTES & REQUIREMENTS ADJACENT ON 4TH STREET, SEE SITE PLAN LOT SIZE:60FT X 100FT = 6,000 SQFT (0.14 AC) BUILDING LOT COVERAGE EXISTING BUILDING LOT COVERAGE 975 SQFT (16.25%) PROPOSED BUILDING LOT COVERAGE 350 SQFT (5.8%) TOTAL = 1,355 SQFT (22%) HARD SURFACE AREA EXISTING HARD SURFACE (NON-POLLUTING)1,080 SQFT NEW HARD SURFACE (NON-POLLUTING)425 SQFT TOTAL EXISTING HARD SURFACE AREA= 1,080 SQFT (18.0%) POLLUTING EXISTING HARD SURFACE (PARKING AREA)0 SQFT POLLUTING PROPOSED HARD SURFACE (PARKING AREA)585 SQFT TOTAL PROPOSED HARD SURFACE AREA= 1,010 SQFT (16.8%) TOTAL ALL HARD SURFACE AREA= 2,015 SQFT (34.8%) PROPOSED USE:SINGLE FAMILY RESIDENTIAL (ADU) OCCUPANCY:SINGLE FAMILY RESIDENTIAL BUILDING AREA AND HEIGHT EXISTING SINGLE FAMILY HOME BUILDING AREA (GROSS)1,620 SQFT 1,970 SQFT (22%) TOTAL BUILDING AREA (GROSS) = 26'-0"BUILDING HEIGHT PROPOSED DADU BUILDING AREA (GROSS)350 SQFT 20'- 4.5"BUILDING HEIGHT CITY OF ANACORTES PLANNING AND BUILDING DEPT: APPROVED PLANS REVIEWED FOR CODE COMPLIANCE PERMIT #:______________________________ ADDRESS:______________________________ APPROVED BY:__________________________ SUBJECT TO FIELD INSPECTION. APPROVED PLANS SHALL NOT BE ALTERED WITHOUT AUTHORIZATION. BLD-2020-0419 508 4th St & EQUIPMENT SPECS ENERGY COMPLIANCE T0.02 ISSUED FOR PERMITDESCRIPTIONDATE COPYRIGHT MOA Architects PC, 2020 All ideas, designs, and plans indicated or represented by these drawings are owned by and are property of Mobile Office Architects PC (MOA) and were created and developed as instruments of service in connection with the specified project. None of such ideas, designs, or plans shall be used for any purpose whatsoever without the written permission of MOA. ARCHITECT MOA DESIGN-BUILD DUSTIN STEPHENS, RA LIC. # 11451 805 722-9083 DSTEPHENS@MO-ARCH.COM OWNER CLARITY MILLER 508 4TH STREET ANACORTES, WA 98221 CLARITYMILLERGOE@GMAIL.COM c MILLER / GOE DETATCHED ADU 508 4TH STREET, ANACORTES, WA 98221 APN P56508 07/13/20 ISSUED FOR PERMIT SEAL & SIGNATURE: ENERGY COMPLIANCE GENERAL NOTES 1. Per Section 502.4.5, the project's building envelope shall be tested to determine air leakage is within acceptable levels. Leakage of .00030 SLA measured at 50 pascals is considered acceptable. Sealing of doors, windows, ducts or registers is not allowed during testing. 2. Section 503.10.2 requires leakage testing of the mechanical ducts, when applicable, to insure that the ducts are sealed. Testing may occur at rough-in or post construction. Testing must comply with standard RS-33. Individuals performing the test must be approved or certified by the WA State University Energy or approved other agency. 3. Per Section 505.1, 75% of all luminaries (lights and lamps) shall be high efficiency. 4. Per Section 105.4, the certificate of energy compliance shall be posted within three feet of the electrical panel, completed by the builder or design professional, and shall include the following information: R-values for ceiling, walls, floors, foundation, U-factors for windows, the type and efficiency of heating/cooling equipment, duct leakage rates from duct testing, and air leakage rates from the blower door testing. A certificate shall be supplied by the permitting agency at the time of permit issuance. 5. All applicable requirements listed on the energy compliance report (sheet T0.02) shall be met. 6. All insulation requirements represented in the energy compliance report are included in the Assemblies Schedule. 7. See floor plans for ventilation notes, see sheet T0.02 for additional mechanical equipment specifications MECHANICAL EQUIPMENT SPECIFICATIONS OUTDOOR HEAT PUMP UNIT: MANUF'R: DAIKIN MODEL # RXB12AXVJU HEATING CAPACITY ----------11,300 BTU COOLING CAPACITY----------11,000 BTU SEER--------------------------------17.0 HSPF---------------------------------9.0 INDOOR HEAT PUMP UNIT: MANUF'R: DAIKIN MODEL # FTXB12AXVJU HEATING CAPACITY ----------11,300 BTU COOLING CAPACITY---------- 11,000 BTU BATHROOM / WHOLE HOUSE EXHAUST FAN / LIGHT COMBO: MANUF'R: PANASONIC MODEL # FV-08VRE2 FLOW RATE-----------------------80 CFM MAX. COOKTOP EXHAUST FAN / MICROWAVE COMBO: MANUF'R: WHIRLPOOL MODEL #WML55011HS FLOW RATE----------------------------400 CFM MAX. EXHAUST AND WHOLE HOUSE VENTILATION WHOLE HOUSE VENTILATION SHALL BE PROVIDED WITH THE BATHROOM EXHAUST VENTILATION FAN SET FOR INTERMITTENT OPERATION CONTROLLED BY A 24-HOUR CLOCK TIMER. RUN TIME SHALL BE SET TO INTERVALS OF 15 MIN "ON" FOLLOWED BY 20 MIN. "OFF" FOR A CALCULATED AIR CHANGE PER HOUR RATE OF 0.38 RATED AT A FLOW OF 80CFM (80CFM X 26 MIN / HR = 2080 CU FT / 5348 CU FT TOTAL VOLUME = 0.38ACH), SEE FLOOR PLAN AND NOTES FOR LOCATION, SEE SHEET T0.02 FOR ADDITIONAL EQUIPMENT INFORMATION EXHAUST FANS SHALL BE PROVIDED AT KITCHEN COOKING, BATHROOM, LAUNDRY, AND OTHER ROOMS WHERE WATER VAPOR OR COOKING ODOR IS PRODUCED. SEE FLOOR PLAN AND NOTES FOR LOCATIONS AND MINIMUM FLOW SPECIFICATIONS. 1a EFFICIENT BUILDING ENVELOPE 1a: Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.28 Floor R-38 Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total UA by 5%. 3b HIGH EFFICIENCY HVAC EQUIPMENT 3b: Air-source heat pump with minimum HSPF of 9.0 To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. EXISTINGSINGLE-FAMILYRESIDENCE,NO CHANGESEXISTING NEIGHBORING FOOD BANK4TH STREET8' X 18'PARKING12FT W X 10FT DEEPGRAVELCONSTRUCTIONENTRANCEEXISTING YARD(NO NEWLANDSCAPING)EXISTING YARD(NO NEW LANDSCAPING)EXISTING YARD(NO NEW LANDSCAPING)EXISTING NEIGHBORINGACCESSORY STRUCTURE10'-0"5'-0"SITE PLAN NOTES //////////////////LOT AREA: 6,000 SQFT, 0.14 AC% OF SITE AREA LANDSCAPEDEXISTING: 4,400 SQFTRETAINED / PROVIDED: 3,300 SQFTPROPOSED: 0REQUIRED: 1,200 SQFT (20%)COMPLIANCE W/ AMC CH 16.50 TREEPRESERVATION:NO PROPOSED TREE REMOVAL ORPLANTING, RETAIN EXISTING CONDITIONSPROPOSED GRADING:+/-20 CU YRDS CUT+/-20 CUT YRDS FILLIMPORTANT NOTE: PROJECT IS SUBJECTTO THE CITY OF ANACORTES MINIMUMSTORMWATER REQUIREMENT #2 AND THE13 ASSOCIATED ELEMENTS. ALL SITEWORK SHALL BE CONDUCTED INACCORDANCE WITH THE STORMWATERREQUIREMENTS. SEE PROJECTSUPPLEMENTAL ATTACHMENTS8' X 18'PARKINGEXISTING NEIGHBORINGACCESSORY STRUCTURESIDEWALK10'-0" MIN.UNDERGROUND ELEC.,DATA, & WATER LINES(E)SEWER LINENEW SEWER CONNECTIONTO EXISTING MAIN LINEALLEYWAYEXISTINGNEIGHBORINGACCESSORYSTRUCTUREEXISTINGNEIGHBORINGACCESSORYSTRUCTUREEXISTINGNEIGHBORINGACCESSORYSTRUCTUREEXISTINGNEIGHBORINGSTRUCTUREPROPOSEDDETACHEDACCESSORYDWELLING UNIT8' X 18'PARKINGSPACE10'-0"18'-0"8'-0" 24FT X 25FT (600 SQFT) REQ'D OPEN SPACE8' X 18'PARKINGSPACE8'-0"10'-0"18'-2 1/2"31'-9 1/2"32'-0"22'-2 1/2"AREA OF PROJECTDISTURBANCE = 1,756 SQFTMARK LIMITS ON SITEPROPERTY LINE 100.0' PROPERTY LINE 100.0'PROPERTY LINE 60.0'PROPERTY LINE 60.0'25'-0"24'-0"(E) SLOPE< 5%CONSTRUCTION SILT FENCE INSTALLEDDURING CONSTRUCTION ALONG ALLEYAND WEST PROPERTY LINE, STARTS HERECONSTRUCTION SILT FENCE INSTALLEDDURING CONSTRUCTION ALONG ALLEYAND WEST PROPERTY LINE, ENDS HERE3" ROUND DOWNSPOUT CONNECT TO (E)STORM WATER SYSTEMSLOPE 2%(E) SLOPE< 5%SLOPE 2% SLOPE 5%CONCRETE WASH OUT AREASLOPE 5%PAVER ENTRY PATIO (40 SQFT)SET HEIGHT 6" BELOW F.F.HEIGHT(E)12" TREE TO BE RETAINED(OUTSIDE WORK AREA)GRAVEL PARKING AREA(585 SQFT)SIDE YARD SETBACK10'-0"10'-0"29'-9"38'-5 5/8"10'-0"SIDE YARD SETBACKFRONT YARD SETBACKREAR YARD SETBACKSLOPE 2%ISSUED FOR PERMITDESCRIPTIONDATE COPYRIGHT MOA Architects PC, 2020All ideas, designs, and plans indicated or representedby these drawings are owned by and are property ofMobile Office Architects PC (MOA) and were createdand developed as instruments of service inconnection with the specified project. None of suchideas, designs, or plans shall be used for anypurpose whatsoever without the written permission ofMOA.ARCHITECTMOA DESIGN-BUILDDUSTIN STEPHENS, RA LIC. # 11451805 722-9083DSTEPHENS@MO-ARCH.COMOWNERCLARITY MILLER508 4TH STREETANACORTES, WA 98221CLARITYMILLERGOE@GMAIL.COMcMILLER / GOEDETATCHED ADU508 4TH STREET,ANACORTES, WA 98221APN P5650807/13/20ISSUED FOR PERMITSEAL & SIGNATURE:01SITE PLANSCALE 1/8" = 1'-0"SITE PLANA100N 14 LOFT 131VTIW 04 01 S A201 N A201 E A201 W A201 $ 2 1 % A301 02 22 0A301 01 A302 03 A302 03 A301 02 A301 01 14 010 1114:1 :1 2 1782 178 01 02 2 03 28 11343 22 0 01 01 02 ( 201 ) 202 6 24 :2:2 :1 :1 03 20 01 12 08 05 06 06 15 13 07 10 09 14 LIVING 179VTIW BATH 49VTIW ENTRY 50VTIW7 43411 612 1134 3 3 8 05 016 17 183 1141 31 33 03 03 0S A201 N A201 E A201 W A201 $ 2 1 % A301 02 22 0A301 01 A302 03 A302 03 A301 02 A301 01 14 0 100 :1 :1 2 112 102 1012 1178(4(44 0 2 178103 19 $ 101 $ 102 % 103 & 104 ' 105 23 6 24 :1 :1 :1 :2 :1 :2 :2 :2 11 S A201 N A201 E A201 W A201 $ 2 1 % A301 02 22 0A301 01 A302 03 A302 03 A301 02 A301 01 14 0 * 301 * 301 * 301 * 301 * 301 * 301 21 21 6/23(6/23( 22 KEY NOTES 1 2 3 245$1*(:29(5+($'9(17 4 5 63/,7+($73803287'22581,7/*24. %78028172$%29(6855281',1**5$'( 21&21&5(7(3$' 6 7 8 9 10 11 12 13 14 15 67$&.('(/(&:$6+(5 '5<(5 2209  9(17'5<(57+58:$//72(;7(5,25 :$7(5+($7(5(/(&50*7$1. 24&2817(5'(37+5()5,*(5$725 )5((=(5 &$'(75(&(66('(/(&75,&:$//+($7(5 &/26(7 %8,/7,1'(6. 62,/ 6(('80522) %8,/7,17$%/( %8,/7,1%(1&+:6725$*(81'(56($7 %8,/7,16+(/9,1* 7$//3$175<&$%,1(7 29(5+($'23(16+(/9,1* 6+,3/$''(572/2)7 3(50($%/(&21&5(7(3$9(5685)$&( 6(775%(/2:'2257+5(6+2/' 16 150$03(/(&3$1(/17 145;240(',&,1(&$%,1(718 5(&(66('&(,/,1*/,*+7 9(17)$1 &20%2 80&)0 6(7217,0(5)25:+2/( +286(9(17,/$7,216((6+((77002)25 63(&6 5(48,5(0(176 19 &2$7+$1*%$5 23(16+2(6+(/9,1* %(/2: 20 4%2;*877(5:35281''2:163287 0$7&+522)&2/25 21 $//6.</,*+76)5$0('%(7:((124 )5$0,1*/$<2876((6758&785$/ )5$0,1*/$<287 22 (;7(5,25)5267)5((+26(%,%23 &20%2602.(&$5%210212;,'( '(7(&725&(,/,1*02817('+$5':,5(' ,17(5&211(&7(':%$77(5<%$&.83 24 WALL TYPES EXTERIOR 2X6 STUD WALL /// WOOD SHEATHING FINISH EXTERIOR (;7(5,25:$//),1,6+ $3$5$7('5871116,',1*6(((;7(5,25 0$7(5,$/66&+('8/()25),1,6+63(&6 29(5 :$7(55(6,67$17%8,/',1*:5$3 2;6678')5$0,1*3(56758&785$/63(&6: 521.5$)7)$&('%$77,168/$7,21,1),// ,17(5,25:$//),1,6+ 58%$/7,&%,5&+3/<:22')$67(1:175 *5.75,0+($'6&5(:6:5(9(56(7+5($' %5$66&2/25 #162&$/,*1)$67(1(5 /$<287 INTERIOR EXTERIOR INTERIOR MARK :1 SECTION DESCRIPTION 6&$/(1 1 0 *OPT 1 F.P. RATING INTERIOR INTERIOR :2 INTERIOR 2X6 STUD WALL /// PTD GWB OR PLYWOOD FINISH INTERIOR -/// WALL CONSTRUCTION IS THE SAME AS WALL TYPE "W3", EXCEPT FOR 2X6 FRAMING /// INTERIOR MARK SECTION DESCRIPTION F.P. RATING FLOOR TYPES CONCRETE SLAB ON GRADE INTERIOR 45(,1)25&('&21&5(7(6/$%3(5 6758&785$/63(&6),1,6+$1'6($/(57%' 25,*,',168/$7,21 510 100,/%/$&.32/<(7+</(1(9$325%$55,(5 2/(9(/,1*6$1' 6&203$&7('*5$9(/ 68%*5$'(3(56758&785$/63(&6 INTERIOR )1 SUBGRADE INTERIOR TYP WOOD FLOOR INTERIOR ),1,6+(':22')/225,1* 34$'9$17(&+7 *68%)/2256+($7+,1* (;32685(1 */8(':68%)/225$'+(6,9( $1'1$,/(' 7-,:22')5$0,1*3(56758&785$/63(&6: 5300,1(5$/:22/,168/$7,21,1),// ,17(5,25&(,/,1*),1,6+ OPTION 1: 37'58*:%/(9(/4),1,6+ OPTION 2:58%$/7,&%,5&+3/<:22')$67(1 :175*5.75,0+($'6&5(:6:5(9(56( 7+5($' %5$66&2/25 #162&$/,*1 )$67(1(5/$<287 INTERIOR )2 INTERIOR INTERIOR 15()(5726758&785$/'5$:,1*6)25$//5(%$5$1'6758&785$/0(0%(56,=,1*$1'&211(&7,216 2)$67(1$//7<3(;'5<:$//:17<3(6'5<:$//6&5(:682&$79(57,&$/-2,176$1'122&$7)/225$1'&(,/,1*5811(56$1' ,17(50(',$7(678'667$**(5-2,176242123326,7(6,'(6 3:$//),1,6+1(('127%($33/,(':+(5(3(50$1(17&$6(:25.,6&29(5,1*7+($33/,&$%/(:$//$5($7<3,&$/*:%0$<%(86(',1 7+(6($5($6:$//-2,1767$3('$1'6$1'('60227+ 812  45()(572),1,6+6&+('8/()25025(,1)250$7,2121),1,6+(6 55()(572(/(9$7,216)25),1,6+/2&$7,216 686(*2/'%21';33853/(%2$5'*:%25(4$/7,1/,(82)67$1'$5'*:%$7$//'$0325:(7/2&$7,216 %$7+6 /$81'5<$5($6  786(&(0(17%2$5'%(+,1'$//7,/($1',1$//',5(&7:(7/2&$7,216 8,17(5,25%$77,168/$7,2172%(KNAUF ECOBATT INSULATION OR EQ. ALT. 9$%29(*5$'(:$7(55(6,67$17%8,/',1*:5$372%(WATERBLOCK SYNTHETIC WATER RESISTANT BUILDING WRAP OR EQ. ALT. 10%(/2:*5$'()281'$7,21:$//:$7(53522),1*72%(DAMP PROOFING PER GC. GENERAL WALL NOTES 6&$/(1 1 0ROOF TYPES6&$/(1 1 0 MARK SECTION DESCRIPTION F.P. RATING METAL ROOFING EXTERIOR 24*$78'((3&2558*$7('522),1*0(7$/ 6$/(625(48$/$/7(51$7( 6(/)$'+(5(':$7(53522),1*0(0%5$1( 81'(5/$<0(17 34$'9$17(&+7 *522)'(&. :22')5$0,1*3(56758&785$/63(&6:15 5105 &/26('&(//635$<)2$0,168/$7,21 $33/,(',1',5(&7&217$&7:81'(56,'(2) 522)6+($7+,1*$1'81)$&('5300,1(5$/ :22/,168/$7,21,1),//%(/2: ,17(5,25&(,/,1*),1,6+ OPTION 1: 37'58*:%/(9(/4),1,6+ OPTION 2:58%$/7,&%,5&+3/<:22')$67(1 :175*5.75,0+($'6&5(:6:5(9(56( 7+5($' %5$66&2/25 #162&$/,*1 )$67(1(5/$<287 INTERIOR 51 EXTERIOR INTERIOR GREEN ROOF EXTERIOR 9(*(7$7,21$663(&,),(' 40$;/2$0<&$&7860,;3/$17,1*62,/ 121:29(1),/7(5)$%5,& '5$,1$*(0$7 5227%$55,(5 3527(&7,21&2856( 600,/(3'00(0%5$1(522),1* 34$'9$17(&+7 *522)'(&. 5,33('726/23(:22')5$0,1*3(5 6758&785$/63(&6:&/26('&(//635$< )2$0,168/$7,21 6$9(5$*(7+,&.1(66542 ,17(5,25&(,/,1*),1,6+ OPTION 1: 37'58*:%/(9(/4),1,6+ OPTION 2:58%$/7,&%,5&+3/<:22')$67(1 :175*5.75,0+($'6&5(:6:5(9(56( 7+5($' %5$66&2/25 #162&$/,*1 )$67(1(5/$<287 INTERIOR EXTERIOR INTERIOR 52 6/23(14)7 GENERAL ROOF NOTES 15()(572),1,6+6&+('8/()25025(,1)250$7,2121),1,6+(6 286(*2/'%21';33853/(%2$5'*:%25(4$/7,1/,(82)67$1'$5'*:%$7$//'$0325:(7/2&$7,216 386(&(0(17%2$5'%(+,1'$//7,/($1',1$//',5(&7:(7/2&$7,216 40,1(5$/:22/,168/$7,2172%(ROCKWOOL COMFORT BATT INSULATION OR EQ. ALT. 5522)32/<6,2,168/$7,2172%(RMAX MULTI-MAX FA-3 OR EQ. ALT. 6&/26('&(//635$<)2$0,168/$7,2172%(FOAM IT GREEN 602 OR EQ. ALT. 76(/)$'+(5(':$7(53522),1*0(0%5$1(81'(5/$<0(1772%(VAPROSHIELD SLOPESHIELD PLUS SA OR EQ. ALT 8'5$,1$*(0$772%(CCW MIRADRAIN GR9400 OR EQ. ALT. 95227%$55,(572%(CCW ROOT-BARRIER OR EQ. ALT. 103527(&7,21&2856(72%(CCW 300HV PROTECTION FABRIC OR EQ. ALT. 11(3'00(0%5$1(522),1*72%(FIRESTONE RUBBERGARD 60MIL EPDM SYSTEM OR EQ. ALT. 15()(572),1,6+6&+('8/()25025(,1)250$7,2121),1,6+(6 286(*2/'%21';33853/(%2$5'*:%25(4$/7,1/,(82)67$1'$5'*:%$7$//'$0325:(7/2&$7,216 386(&(0(17%2$5'%(+,1'$//7,/($1',1$//',5(&7:(7/2&$7,216 4:$7(53522),1*0(0%5$1($77,/()/22567258183:$//6$0,12)6 5,17(5,25%$77,168/$7,2172%(KNAUF ECOBATT INSULATION OR EQ. ALT. 6%(/2:*5$'(,168/$7,2172%(OWENS CORNING FOAMULAR 250 (XPS) OR EQ. ALT. 7)/225:$7(53522),1*0(0%5$1(72%(LATICRETE 9235 OR EQ. ALT. GENERAL FLOOR NOTES INTERIOR INTERIOR :3 INTERIOR 2X4 STUD WALL /// PTD GWB OR PLYWOOD FINISH INTERIOR -/// WALL CONSTRUCTION IS THE SAME AS WALL TYPE "W3", EXCEPT FOR 2X6 FRAMING /// INTERIORNOWINDOW DIM (R.O.)LOCATION WIDTH HEIGHT REMARKSWINDOW TYPE SILL HEIGHT (R.O.) WINDOW SCHEDULE 2 04 0101 102 2 11:+,7($),%(5*/$66/,9,1*0$59,1(66(17,$/ &2//(&7,21 3 04 0103 2 11%),%(5*/$66 OPERATION FINISH EXTINT ENERGY SPECS SHGCU-VALUE :+,7(%/$&. %/$&.&$6(0(17 ),;(' 6((*(1 127(6 6((*(1 127(6 6((*(1 127(6 6((*(1 127(6 7 02 0104 2 11&),%(5*/$66 :+,7(%/$&.$:1,1*6((*(1 127(6 6((*(1 127(6 $:1,1*3$,508//(' 3 04 0105 2 11'),%(5*/$66 :+,7(%/$&.6((*(1 127(6 6((*(1 127(6 106 GENERAL WINDOW NOTES 1),(/'9(5,)<$//528*+23(1,1*635,257225'(5,1* 2$//:,1'2:66+$//%(,168/$7(':,7+$0,1,08089$/8(2)03025$1$9(5$*('727$/ 352-(&79$/8(2)802825/(666(((1(5*<$1$/<6,6 35()(5723/$16$1'(;7(5,25(/(9$7,216729(5,)<:,1'2:23(5$7,216256:,1*6 46+23'5$:,1*66+$//%(3529,'(')25$//:,1'2:6$1'*/$=('6:,1* '2256 5:,1'2:*/$=,1*72%( -MARVIN DOUBLE PANE, "LOW-E1", ARGON FILL PANEL %$7+ /2)7 NO DOOR SCHEDULE DOOR DIM GENERAL DOOR NOTES (175< LOCATION WIDTH HEIGHT MANUF.REMARKS 100 DOOR TYPE 15()(5723/$16)256:,1*62)'2256$1''225+$1',1* 2),(/'9(5,)<$//&21',7,216)253/$&(0(176,=($1''(7$,/6 381'(5&87$//,17(5,25'2256)250,1,080&/($5$1&($%29()/225),1,6+$1'$//2:)25$,5029(0(179,):$5&+,7(&7 43529,'($//6($/6*$6.(76$1''2256:((3621$//(175<'22563529,'(),5(602.(5$7('6($/6$65(4 ' 5$//(175<'225+$5':$5(6+$//%((48,33(':'($'/2&.,1*/$7&+%2/7:,7+$7/($67$127+52:7+$73(1(75$7(67+(675,.(5127/(667+$114$1'6+$//%(23(1$%/()5207+(,16,'(:,7+28786(2)$ .(<2563(&,$/.12:/('*(25())257 46+23'5$:,1*66+$//%(3529,'(')25$//*/$=('6:,1*'2256 THICK- NESS MAT'L FINISH 7%' 101 (;76:,1* 1ST FLOOR 62/,'&25( :22' 6&: ,176:,1* 3 06 8134'87&+'225 (175<,17%,)2/'2 66 8138 102 %$7+ 7%' 3(5*& 103 6&: 6 8%$7+3(5*&7%' 3(5*& 2 66 81387%'3(5*& 6&: / MODEL ,17%,)2/' /289(5('2 6:22'138 MANUF. / MODEL FRAME MAT'RL /,9,1* /,9,1* 08//('72:,1'2:103 08//('72:,1'2:1011020$59,1(66(17,$/ &2//(&7,21 0$59,1(66(17,$/ &2//(&7,21 0$59,1(66(17,$/ &2//(&7,21 9(/8;)&0 ( 106 /2)7 ) 106 522)* &$6(0(17 &$6(0(17 ),;(' ),;(' 3 03 0 3 03 0 1 1053 1051$:+,7(%/$&. 0$59,1(66(17,$/ &2//(&7,21 0$59,1(66(17,$/ &2//(&7,21 ),%(5*/$66 ),%(5*/$66 :+,7(%/$&.6((*(1 127(6 6((*(1 127(6 :+,7(%/$&.6((*(1 127(6 6((*(1 127(6 4 0 4 0 ),%(5*/$66 043 027 ISSUED FOR PERMIT'(6&5,37,21'$7( &23<5,*+702$$UFKLWHFWV3&2020 $OOLGHDVGHVLJQVDQGSODQVLQGLFDWHGRUUHSUHVHQWHG E\WKHVHGUDZLQJVDUHRZQHGE\DQGDUHSURSHUW\RI 0RELOH2IILFH$UFKLWHFWV3& 02$ DQGZHUHFUHDWHG DQGGHYHORSHGDVLQVWUXPHQWVRIVHUYLFHLQ FRQQHFWLRQZLWKWKHVSHFLILHGSURMHFW1RQHRIVXFK LGHDVGHVLJQVRUSODQVVKDOOEHXVHGIRUDQ\ SXUSRVHZKDWVRHYHUZLWKRXWWKHZULWWHQSHUPLVVLRQRI 02$ ARCHITECT MOA DESIGN-BUILD DUSTIN STEPHENS, RA LIC. # 11451 805 722-9083 DSTEPHENS@MO-ARCH.COM OWNER CLARITY MILLER 508 4TH STREET ANACORTES, WA 98221 CLARITYMILLERGOE@GMAIL.COM F 0,//(5*2( '(7$7&+('$'8 50847+675((7 $1$&257(6:$98221 $31356508 071320 ,668(')253(50,7 6($/ 6,*1$785( 1 GROUND FLOOR CONSTRUCTION PLAN SCALE: 1/4"=1'-0" A101 CONSTRUCTION PLANS 2 LOFT LEVEL CONSTRUCTION PLAN SCALE: 1/4"=1'-0"3 ROOF PLAN SCALE: 1/4"=1'-0" Washing machine hookups shall be accessible, and drains shall be readily accessible under UPC 606.6, 804.1. Provide louvered doors or 100sq” make up air opening at dryer Closet. 12 EX-03 EX-01 EX-04 EX-05 /-20'-4.5" T.O. ROOF 0'-0" T.O. FINISHED SLAB 12'-6" T.O. TOP PLATE 7'-11.625" T.O.F.F. - LOFT 7'-0.625" T.O. TOP PLATE EX-03 EX-01 EX-04 BA 25-FOOT HEIGHT LIMIT 45 DEGREE HEIGHT LIMIT OFF SIDE YARD SETBACK15'-0"SIDE YARD SETBACKSIDE PROPERTY LINEEX-02 /-20'-4.5" T.O. ROOF 0'-0" T.O. FINISHED SLAB 12'-6" T.O. TOP PLATE 7'-11.625" T.O.F.F. - LOFT 7'-0.625" T.O. TOP PLATE 5'-0" 12 12 EX-03 EX-03 EX-01 EX-04 AB /-20'-4.5" T.O. ROOF 0'-0" T.O. FINISHED SLAB 12'-6" T.O. TOP PLATE 7'-11.625" T.O.F.F. - LOFT 7'-0.625" T.O. TOP PLATE EX-02 12 12 /-20'-4.5" T.O. ROOF 0'-0" T.O. FINISHED SLAB 12'-6" T.O. TOP PLATE 7'-11.625" T.O.F.F. - LOFT 7'-0.625" T.O. TOP PLATE 21 EX-03 EX-01 EX-04 EX-02 EX-03 EXTERIOR MATERIALS SCHEDULE APA RATED T1-11 SHEATHINGEX-01 TAG PRODUCT NAME / No.COLOR FINISH SIZE REMARKSMATERIAL / DESCRIPTION MANUFACTURER TBD CABOT'S SEMI-SOLID STAIN 4FT X 8FT X 5/8IN THICK RUN PANELS VERTICALLY, STAGGER SEAMS AS SHOWN IN ELEVATIONS APA RATED PRESSURE TREATED PLYWOODEX-02 EX-03 CORRUGATED METAL ROOF & MATCHING TRIM / FLASHING 24GAMETAL SALES OR EQ. ALT.7/8" CORRUGATED TBD FACTORY FINISH COLOR SELECTION TO BE CERTIFIED BY COOL ROOF RATING COUNCIL 4FT X 8FT X 5/8IN THICK CABOT'S SEMI-SOLID STAINTBD FASTEN WITH SS DECKING SCREWS AT MEASURED AND EQUALLY SPACED PLACEMENT EX-04 CONCRETE COVER BOARD 1/2" THICK PANELTBDFACTORY FINISH FASTEN W/ SS CONCRETE SCREWS ISSUED FOR PERMITDESCRIPTIONDATE COPYRIGHT MOA Architects PC, 2020 All ideas, designs, and plans indicated or represented by these drawings are owned by and are property of Mobile Office Architects PC (MOA) and were created and developed as instruments of service in connection with the specified project. None of such ideas, designs, or plans shall be used for any purpose whatsoever without the written permission of MOA. ARCHITECT MOA DESIGN-BUILD DUSTIN STEPHENS, RA LIC. # 11451 805 722-9083 DSTEPHENS@MO-ARCH.COM OWNER CLARITY MILLER 508 4TH STREET ANACORTES, WA 98221 CLARITYMILLERGOE@GMAIL.COM c MILLER / GOE DETATCHED ADU 508 4TH STREET, ANACORTES, WA 98221 APN P56508 07/13/20 ISSUED FOR PERMIT SEAL & SIGNATURE: 1 EAST ELEVATION SCALE: 1/4"=1'-0"A201 EXTERIOR ELEVATIONS 2 WEST ELEVATION SCALE: 1/4"=1'-0" 3 SOUTH ELEVATION SCALE: 1/4"=1'-0"4 NORTH ELEVATION SCALE: 1/4"=1'-0" 7'-0"2'-5"12 12 R1 F2 F1 +0-0" (EL. +0'-0") 01 FLOOR +/- 20'-4.5" T.O. ROOF +7'-11.625" F.F. LOFT +7'-5/8" TOP PLATE @ LOFT FRAMING +12'-6" TOP PLATE @ ROOF FRAMING AB 8" TYP. R10 CONT. RIGID SLAB PERIMETER INSULATION 3" MIN., TYP.1 1/2" MIN. COVERAGE, TYP. 2'-0"BITUMINOUS DAMP-PROOFING AT SLAB EDGE 1/2" CONCRETE PROTECTION BOARD 24GA Z-FLASHING OVER PROTECTION BOARD 2X6 PT LOWER SILL PLATE W/ 2X6 UPPER PLATE, PROVIDE CONT. FOAM SILL SEAL BETWEEN LOWER PLATE & CONCRETE ANCHOR BOLTS PER SHEAR WALL SCHEDULE WALL ASSEMBLY PER PLAN 2X6 SILL PLATE OVER LOFT SUBFLOOR 9 1/2" X 1 1/4" LVL RIM JOIST, TYP. 2X6 DOUBLE TOP PLATE 2X6 SILL PLATE OVER LOFT SUBFLOOR SINGLE TOP PLATE OVER WINDOW OPENING LVL RIM ACTS AS WINDOW HEADER, PROVIDE TJI HANGER FOR ANY JOIST ATTACHMENT OVER WINDOW (3) CONT. #4 HORIZ. REINFORCEMENT BARS WELDED WIRE REINFORCEMENT PER STRUCTURAL PLANS #4 BENT HOOKS @ MAX. 48" O.C. 4" BOX GUTTER W/ SS FINE MESH GUTTER GUARD AND 3" ROUND DOWNSPOUTS DOUBLE TOP PLATE SKYLIGHT INSTALLATION PER MANUF'R INSTALLATION INSTRUCTIONS, COORDINATE RAFTER LAYOUT WITH SKYLIGHT ROUGH OPENINGS 2X10 RAFTER TAIL BEYOND BIRDSMOUTH NOTCH. NOTE THAT RAFTER STRUCTURAL ANALYSIS IS SHOWN FOR 2X8 RAFTER TO ACCOUNT FOR DEEPER BIRDSMOUTH NOTCH. MAX NOTCH FOR 2X8 SIZE = 1.8125", TAIL DEPTH REQ'D = 7.25" - 1.8125" = 5.1875". 5.375" PROVIDED. GRADE SLOPES AWAY FROM BUILDING MIN. 1/4" PER FT, TYP. ALL SIDES 12" MIN., (FROST DEPTH)+0-0" (EL. +0'-0") 01 FLOOR +/- 20'-4.5" T.O. ROOF +7'-11.625" F.F. LOFT +7'-5/8" TOP PLATE @ LOFT FRAMING +12'-6" TOP PLATE @ ROOF FRAMING R1 F1 R2 AB 3'-0"7'-0"12 12 12" WIDE X 4" HIGH ALUMINUM SCUPPER OVERFLOW DRAIN, CONSTRUCT WITH 1/8" ALUMINUM SHEET 2X4 BUILT-UP CURB, ROOF MEMBRANE WRAPS COMPLETELY OVER CURB WITH WELDED SEAMS AND 4" DOWN VERTICAL FACE OF WALL, PROVIDE METAL FLASHING CAP Z-FLASHING AT SIDING TO ROOF MEMBRANE TRANSITION, ROOF MEMBRANE RUNS MIN. 4" ABOVE TOP OF PARAPET CURB, UP WALL AND UNDER Z-FLASHING 4X4 APPEARANCE GRADE POST W/ (2) 1/2" PLAIN STEEL BOLTS, USE SIMPSON DTTZ TIE AT TOP BOLT. 36" SOLID WALL FASTENS TO POSTS TO PROVIDE GUARDRAIL. SHIP LADDER ACCESS TO LOFT TV LOCATION WALL TYPES EXTERIOR 2X6 STUD WALL /// WOOD SHEATHING FINISH EXTERIOR -EXTERIOR WALL FINISH --- APA RATED 5/8" T1-11 SIDING, SEE EXTERIOR MATERIALS SCHEDULE FOR FINISH SPECS. OVER/ -WATER RESISTANT BUILDING WRAP -2X6 STUD FRAMING PER STRUCTURAL SPECS W/ R-21 KRAFT FACED BATT INSULATION INFILL -INTERIOR WALL FINISH --- 5/8" BALTIC BIRCH PLYWOOD, FASTEN W/ 1.75" GRK TRIM-HEAD SCREWS W/ REVERSE THREAD ("BRASS COLOR") @ 16" O.C., ALIGN FASTENER LAYOUT INTERIOR EXTERIOR INTERIOR MARK W1 SECTION DESCRIPTION SCALE: 1" = 1'-0" *OPT 1 F.P. RATING INTERIOR INTERIOR W2 INTERIOR 2X6 STUD WALL /// PTD GWB OR PLYWOOD FINISH INTERIOR -/// WALL CONSTRUCTION IS THE SAME AS WALL TYPE "W3", EXCEPT FOR 2X6 FRAMING /// INTERIOR MARK SECTION DESCRIPTION F.P. RATING FLOOR TYPES CONCRETE SLAB ON GRADE INTERIOR -4" REINFORCED CONCRETE SLAB PER STRUCTURAL SPECS, FINISH AND SEALER TBD -2" RIGID INSULATION (R-10) -10 MIL BLACK POLYETHYLENE VAPOR BARRIER -2" LEVELING SAND -6" COMPACTED GRAVEL -SUBGRADE PER STRUCTURAL SPECS INTERIOR F1 SUBGRADE INTERIOR TYP WOOD FLOOR INTERIOR -FINISHED WOOD FLOORING -3/4" ADVANTECH T&G SUBFLOOR SHEATHING (EXPOSURE 1), GLUED W/ SUBFLOOR ADHESIVE AND NAILED -TJI WOOD FRAMING PER STRUCTURAL SPECS W/ R-30 MINERAL WOOL INSULATION INFILL -INTERIOR CEILING FINISH --- OPTION 1: PTD 5/8" GWB, LEVEL 4 FINISH OPTION 2: 5/8" BALTIC BIRCH PLYWOOD, FASTEN W/ 1.75" GRK TRIM-HEAD SCREWS W/ REVERSE THREAD ("BRASS COLOR") @ 16" O.C., ALIGN FASTENER LAYOUT INTERIOR F2 INTERIOR INTERIOR 1.REFER TO STRUCTURAL DRAWINGS FOR ALL REBAR AND STRUCTURAL MEMBER SIZING AND CONNECTIONS. 2.FASTEN ALL TYPE-X DRYWALL W/ 1" TYPE-S DRYWALL SCREWS 8" O.C. AT VERTICAL JOINTS AND 12" O.C. AT FLOOR AND CEILING RUNNERS AND INTERMEDIATE STUDS. STAGGER JOINTS 24" ON OPPOSITE SIDES. 3.WALL "FINISH" NEED NOT BE APPLIED WHERE PERMANENT CASEWORK IS COVERING THE APPLICABLE WALL AREA. TYPICAL GWB MAY BE USED IN THESE AREAS W/ ALL JOINTS TAPED AND SANDED SMOOTH (UNO). 4.REFER TO FINISH SCHEDULE FOR MORE INFORMATION ON FINISHES 5.REFER TO ELEVATIONS FOR FINISH LOCATIONS 6.USE GOLD BOND XP PURPLE BOARD GWB OR EQ. ALT. IN LIEU OF STANDARD GWB AT ALL DAMP OR WET LOCATIONS (BATHS & LAUNDRY AREAS). 7.USE CEMENT BOARD BEHIND ALL TILE AND IN ALL DIRECT WET LOCATIONS. 8.INTERIOR BATT INSULATION TO BE: KNAUF ECOBATT INSULATION OR EQ. ALT. 9.ABOVE GRADE WATER RESISTANT BUILDING WRAP TO BE: WATERBLOCK SYNTHETIC WATER RESISTANT BUILDING WRAP OR EQ. ALT. 10.BELOW GRADE FOUNDATION WALL WATERPROOFING TO BE: DAMP PROOFING PER GC. GENERAL WALL NOTES SCALE: 1" = 1'-0"ROOF TYPESSCALE: 1" = 1'-0" MARK SECTION DESCRIPTION F.P. RATING METAL ROOFING EXTERIOR -24GA 7/8" DEEP CORRUGATED ROOFING, METAL SALES OR EQUAL ALTERNATE -SELF-ADHERED WATERPROOFING MEMBRANE UNDERLAYMENT -3/4" ADVANTECH T&G ROOF DECK -WOOD FRAMING PER STRUCTURAL SPECS W/ 1.5" (R10.5) CLOSED CELL SPRAY FOAM INSULATION APPLIED IN DIRECT CONTACT W/ UNDERSIDE OF ROOF SHEATHING AND UNFACED R-30 MINERAL WOOL INSULATION INFILL BELOW. -INTERIOR CEILING FINISH --- OPTION 1: PTD 5/8" GWB, LEVEL 4 FINISH OPTION 2: 5/8" BALTIC BIRCH PLYWOOD, FASTEN W/ 1.75" GRK TRIM-HEAD SCREWS W/ REVERSE THREAD ("BRASS COLOR") @ 16" O.C., ALIGN FASTENER LAYOUT INTERIOR R1 EXTERIOR INTERIOR GREEN ROOF EXTERIOR -VEGETATION AS SPECIFIED -4" MAX LOAMY "CACTUS MIX" PLANTING SOIL -NON-WOVEN FILTER FABRIC -DRAINAGE MAT -ROOT BARRIER -PROTECTION COURSE -60 MIL EPDM MEMBRANE ROOFING -3/4" ADVANTECH T&G ROOF DECK -RIPPED TO SLOPE WOOD FRAMING PER STRUCTURAL SPECS W/ CLOSED CELL SPRAY FOAM INSULATION (6" AVERAGE THICKNESS, R-42) -INTERIOR CEILING FINISH --- OPTION 1: PTD 5/8" GWB, LEVEL 4 FINISH OPTION 2: 5/8" BALTIC BIRCH PLYWOOD, FASTEN W/ 1.75" GRK TRIM-HEAD SCREWS W/ REVERSE THREAD ("BRASS COLOR") @ 16" O.C., ALIGN FASTENER LAYOUT INTERIOR EXTERIOR INTERIOR R2 SLOPE 1/4":FT GENERAL ROOF NOTES 1.REFER TO FINISH SCHEDULE FOR MORE INFORMATION ON FINISHES 2.USE GOLD BOND XP PURPLE BOARD GWB OR EQ. ALT. IN LIEU OF STANDARD GWB AT ALL DAMP OR WET LOCATIONS. 3.USE CEMENT BOARD BEHIND ALL TILE AND IN ALL DIRECT WET LOCATIONS. 4.MINERAL WOOL INSULATION TO BE: ROCKWOOL COMFORT BATT INSULATION OR EQ. ALT. 5.ROOF POLYSIO INSULATION TO BE: RMAX MULTI-MAX FA-3 OR EQ. ALT. 6.CLOSED CELL SPRAY FOAM INSULATION TO BE: FOAM IT GREEN 602 OR EQ. ALT. 7.SELF-ADHERED WATERPROOFING MEMBRANE UNDERLAYMENT TO BE: VAPROSHIELD SLOPESHIELD PLUS SA OR EQ. ALT 8.DRAINAGE MAT TO BE: CCW MIRADRAIN GR9400 OR EQ. ALT. 9.ROOT BARRIER TO BE: CCW ROOT-BARRIER OR EQ. ALT. 10.PROTECTION COURSE TO BE: CCW 300HV PROTECTION FABRIC OR EQ. ALT. 11.EPDM MEMBRANE ROOFING TO BE: FIRESTONE RUBBERGARD 60MIL EPDM SYSTEM OR EQ. ALT. 1.REFER TO FINISH SCHEDULE FOR MORE INFORMATION ON FINISHES 2.USE GOLD BOND XP PURPLE BOARD GWB OR EQ. ALT. IN LIEU OF STANDARD GWB AT ALL DAMP OR WET LOCATIONS. 3.USE CEMENT BOARD BEHIND ALL TILE AND IN ALL DIRECT WET LOCATIONS. 4.WATERPROOFING MEMBRANE AT TILE FLOORS TO RUN UP WALLS A MIN. OF 6" 5.INTERIOR BATT INSULATION TO BE: KNAUF ECOBATT INSULATION OR EQ. ALT. 6.BELOW GRADE INSULATION TO BE: OWENS CORNING FOAMULAR 250 (XPS) OR EQ. ALT. 7.FLOOR WATERPROOFING MEMBRANE TO BE: LATICRETE 9235 OR EQ. ALT. GENERAL FLOOR NOTES INTERIOR INTERIOR W3 INTERIOR 2X4 STUD WALL /// PTD GWB OR PLYWOOD FINISH INTERIOR -/// WALL CONSTRUCTION IS THE SAME AS WALL TYPE "W3", EXCEPT FOR 2X6 FRAMING /// INTERIOR ISSUED FOR PERMITDESCRIPTIONDATE COPYRIGHT MOA Architects PC, 2020 All ideas, designs, and plans indicated or represented by these drawings are owned by and are property of Mobile Office Architects PC (MOA) and were created and developed as instruments of service in connection with the specified project. None of such ideas, designs, or plans shall be used for any purpose whatsoever without the written permission of MOA. ARCHITECT MOA DESIGN-BUILD DUSTIN STEPHENS, RA LIC. # 11451 805 722-9083 DSTEPHENS@MO-ARCH.COM OWNER CLARITY MILLER 508 4TH STREET ANACORTES, WA 98221 CLARITYMILLERGOE@GMAIL.COM c MILLER / GOE DETATCHED ADU 508 4TH STREET, ANACORTES, WA 98221 APN P56508 07/13/20 ISSUED FOR PERMIT SEAL & SIGNATURE: 1 BUILDING CROSS SECTION SCALE: 1/4"=1'-0"2 BUILDING CROSS SECTION SCALE: 1/4"=1'-0" A301 CONSTRUCTION SECTIONS 1 2 +0-0" (EL. +0'-0") 01 FLOOR +/- 20'-4.5" T.O. ROOF +7'-11.625" F.F. LOFT +7'-5/8" TOP PLATE @ LOFT FRAMING +12'-6" TOP PLATE @ ROOF FRAMING 3'-0"7'-0"3'-0"3'-0"WALL TYPES EXTERIOR 2X6 STUD WALL /// WOOD SHEATHING FINISH EXTERIOR -EXTERIOR WALL FINISH --- APA RATED 5/8" T1-11 SIDING, SEE EXTERIOR MATERIALS SCHEDULE FOR FINISH SPECS. OVER/ -WATER RESISTANT BUILDING WRAP -2X6 STUD FRAMING PER STRUCTURAL SPECS W/ R-21 KRAFT FACED BATT INSULATION INFILL -INTERIOR WALL FINISH --- 5/8" BALTIC BIRCH PLYWOOD, FASTEN W/ 1.75" GRK TRIM-HEAD SCREWS W/ REVERSE THREAD ("BRASS COLOR") @ 16" O.C., ALIGN FASTENER LAYOUT INTERIOR EXTERIOR INTERIOR MARK W1 SECTION DESCRIPTION SCALE: 1" = 1'-0" *OPT 1 F.P. RATING INTERIOR INTERIOR W2 INTERIOR 2X6 STUD WALL /// PTD GWB OR PLYWOOD FINISH INTERIOR -/// WALL CONSTRUCTION IS THE SAME AS WALL TYPE "W3", EXCEPT FOR 2X6 FRAMING /// INTERIOR MARK SECTION DESCRIPTION F.P. RATING FLOOR TYPES CONCRETE SLAB ON GRADE INTERIOR -4" REINFORCED CONCRETE SLAB PER STRUCTURAL SPECS, FINISH AND SEALER TBD -2" RIGID INSULATION (R-10) -10 MIL BLACK POLYETHYLENE VAPOR BARRIER -2" LEVELING SAND -6" COMPACTED GRAVEL -SUBGRADE PER STRUCTURAL SPECS INTERIOR F1 SUBGRADE INTERIOR TYP WOOD FLOOR INTERIOR -FINISHED WOOD FLOORING -3/4" ADVANTECH T&G SUBFLOOR SHEATHING (EXPOSURE 1), GLUED W/ SUBFLOOR ADHESIVE AND NAILED -TJI WOOD FRAMING PER STRUCTURAL SPECS W/ R-30 MINERAL WOOL INSULATION INFILL -INTERIOR CEILING FINISH --- OPTION 1: PTD 5/8" GWB, LEVEL 4 FINISH OPTION 2: 5/8" BALTIC BIRCH PLYWOOD, FASTEN W/ 1.75" GRK TRIM-HEAD SCREWS W/ REVERSE THREAD ("BRASS COLOR") @ 16" O.C., ALIGN FASTENER LAYOUT INTERIOR F2 INTERIOR INTERIOR 1.REFER TO STRUCTURAL DRAWINGS FOR ALL REBAR AND STRUCTURAL MEMBER SIZING AND CONNECTIONS. 2.FASTEN ALL TYPE-X DRYWALL W/ 1" TYPE-S DRYWALL SCREWS 8" O.C. AT VERTICAL JOINTS AND 12" O.C. AT FLOOR AND CEILING RUNNERS AND INTERMEDIATE STUDS. STAGGER JOINTS 24" ON OPPOSITE SIDES. 3.WALL "FINISH" NEED NOT BE APPLIED WHERE PERMANENT CASEWORK IS COVERING THE APPLICABLE WALL AREA. TYPICAL GWB MAY BE USED IN THESE AREAS W/ ALL JOINTS TAPED AND SANDED SMOOTH (UNO). 4.REFER TO FINISH SCHEDULE FOR MORE INFORMATION ON FINISHES 5.REFER TO ELEVATIONS FOR FINISH LOCATIONS 6.USE GOLD BOND XP PURPLE BOARD GWB OR EQ. ALT. IN LIEU OF STANDARD GWB AT ALL DAMP OR WET LOCATIONS (BATHS & LAUNDRY AREAS). 7.USE CEMENT BOARD BEHIND ALL TILE AND IN ALL DIRECT WET LOCATIONS. 8.INTERIOR BATT INSULATION TO BE: KNAUF ECOBATT INSULATION OR EQ. ALT. 9.ABOVE GRADE WATER RESISTANT BUILDING WRAP TO BE: WATERBLOCK SYNTHETIC WATER RESISTANT BUILDING WRAP OR EQ. ALT. 10.BELOW GRADE FOUNDATION WALL WATERPROOFING TO BE: DAMP PROOFING PER GC. GENERAL WALL NOTES SCALE: 1" = 1'-0"ROOF TYPESSCALE: 1" = 1'-0" MARK SECTION DESCRIPTION F.P. RATING METAL ROOFING EXTERIOR -24GA 7/8" DEEP CORRUGATED ROOFING, METAL SALES OR EQUAL ALTERNATE -SELF-ADHERED WATERPROOFING MEMBRANE UNDERLAYMENT -3/4" ADVANTECH T&G ROOF DECK -WOOD FRAMING PER STRUCTURAL SPECS W/ 1.5" (R10.5) CLOSED CELL SPRAY FOAM INSULATION APPLIED IN DIRECT CONTACT W/ UNDERSIDE OF ROOF SHEATHING AND UNFACED R-30 MINERAL WOOL INSULATION INFILL BELOW. -INTERIOR CEILING FINISH --- OPTION 1: PTD 5/8" GWB, LEVEL 4 FINISH OPTION 2: 5/8" BALTIC BIRCH PLYWOOD, FASTEN W/ 1.75" GRK TRIM-HEAD SCREWS W/ REVERSE THREAD ("BRASS COLOR") @ 16" O.C., ALIGN FASTENER LAYOUT INTERIOR R1 EXTERIOR INTERIOR GREEN ROOF EXTERIOR -VEGETATION AS SPECIFIED -4" MAX LOAMY "CACTUS MIX" PLANTING SOIL -NON-WOVEN FILTER FABRIC -DRAINAGE MAT -ROOT BARRIER -PROTECTION COURSE -60 MIL EPDM MEMBRANE ROOFING -3/4" ADVANTECH T&G ROOF DECK -RIPPED TO SLOPE WOOD FRAMING PER STRUCTURAL SPECS W/ CLOSED CELL SPRAY FOAM INSULATION (6" AVERAGE THICKNESS, R-42) -INTERIOR CEILING FINISH --- OPTION 1: PTD 5/8" GWB, LEVEL 4 FINISH OPTION 2: 5/8" BALTIC BIRCH PLYWOOD, FASTEN W/ 1.75" GRK TRIM-HEAD SCREWS W/ REVERSE THREAD ("BRASS COLOR") @ 16" O.C., ALIGN FASTENER LAYOUT INTERIOR EXTERIOR INTERIOR R2 SLOPE 1/4":FT GENERAL ROOF NOTES 1.REFER TO FINISH SCHEDULE FOR MORE INFORMATION ON FINISHES 2.USE GOLD BOND XP PURPLE BOARD GWB OR EQ. ALT. IN LIEU OF STANDARD GWB AT ALL DAMP OR WET LOCATIONS. 3.USE CEMENT BOARD BEHIND ALL TILE AND IN ALL DIRECT WET LOCATIONS. 4.MINERAL WOOL INSULATION TO BE: ROCKWOOL COMFORT BATT INSULATION OR EQ. ALT. 5.ROOF POLYSIO INSULATION TO BE: RMAX MULTI-MAX FA-3 OR EQ. ALT. 6.CLOSED CELL SPRAY FOAM INSULATION TO BE: FOAM IT GREEN 602 OR EQ. ALT. 7.SELF-ADHERED WATERPROOFING MEMBRANE UNDERLAYMENT TO BE: VAPROSHIELD SLOPESHIELD PLUS SA OR EQ. ALT 8.DRAINAGE MAT TO BE: CCW MIRADRAIN GR9400 OR EQ. ALT. 9.ROOT BARRIER TO BE: CCW ROOT-BARRIER OR EQ. ALT. 10.PROTECTION COURSE TO BE: CCW 300HV PROTECTION FABRIC OR EQ. ALT. 11.EPDM MEMBRANE ROOFING TO BE: FIRESTONE RUBBERGARD 60MIL EPDM SYSTEM OR EQ. ALT. 1.REFER TO FINISH SCHEDULE FOR MORE INFORMATION ON FINISHES 2.USE GOLD BOND XP PURPLE BOARD GWB OR EQ. ALT. IN LIEU OF STANDARD GWB AT ALL DAMP OR WET LOCATIONS. 3.USE CEMENT BOARD BEHIND ALL TILE AND IN ALL DIRECT WET LOCATIONS. 4.WATERPROOFING MEMBRANE AT TILE FLOORS TO RUN UP WALLS A MIN. OF 6" 5.INTERIOR BATT INSULATION TO BE: KNAUF ECOBATT INSULATION OR EQ. ALT. 6.BELOW GRADE INSULATION TO BE: OWENS CORNING FOAMULAR 250 (XPS) OR EQ. ALT. 7.FLOOR WATERPROOFING MEMBRANE TO BE: LATICRETE 9235 OR EQ. ALT. GENERAL FLOOR NOTES INTERIOR INTERIOR W3 INTERIOR 2X4 STUD WALL /// PTD GWB OR PLYWOOD FINISH INTERIOR -/// WALL CONSTRUCTION IS THE SAME AS WALL TYPE "W3", EXCEPT FOR 2X6 FRAMING /// INTERIOR ISSUED FOR PERMITDESCRIPTIONDATE COPYRIGHT MOA Architects PC, 2020 All ideas, designs, and plans indicated or represented by these drawings are owned by and are property of Mobile Office Architects PC (MOA) and were created and developed as instruments of service in connection with the specified project. None of such ideas, designs, or plans shall be used for any purpose whatsoever without the written permission of MOA. ARCHITECT MOA DESIGN-BUILD DUSTIN STEPHENS, RA LIC. # 11451 805 722-9083 DSTEPHENS@MO-ARCH.COM OWNER CLARITY MILLER 508 4TH STREET ANACORTES, WA 98221 CLARITYMILLERGOE@GMAIL.COM c MILLER / GOE DETATCHED ADU 508 4TH STREET, ANACORTES, WA 98221 APN P56508 07/13/20 ISSUED FOR PERMIT SEAL & SIGNATURE: 3 BUILDING LONGITUDINAL SECTION SCALE: 1/4"=1'-0" A301 CONSTRUCTION SECTIONS A21B22'-0"14'-0"A21B22'-0"14'-0"N2LOFT LEVEL SHEARWALL PLANSCALE 1/4" = 1'-0"PLANSSTRUCTURALS100ISSUED FOR PERMITDESCRIPTIONDATE COPYRIGHT MOA Architects PC, 2020All ideas, designs, and plans indicated or representedby these drawings are owned by and are property ofMobile Office Architects PC (MOA) and were createdand developed as instruments of service inconnection with the specified project. None of suchideas, designs, or plans shall be used for anypurpose whatsoever without the written permission ofMOA.ARCHITECTMOA DESIGN-BUILDDUSTIN STEPHENS, RA LIC. # 11451805 722-9083DSTEPHENS@MO-ARCH.COMOWNERCLARITY MILLER508 4TH STREETANACORTES, WA 98221CLARITYMILLERGOE@GMAIL.COMcMILLER / GOEDETATCHED ADU508 4TH STREET,ANACORTES, WA 98221APN P5650807/13/20ISSUED FOR PERMITSEAL & SIGNATURE:N1GROUND LEVEL SHEARWALL PLANSCALE 1/4" = 1'-0"MARKSHEARWALL SCHEDULESHEATHINGNOTES7/16" CD-X OR OSB OR5/8" T1-11 (1) FACESHEARWALL NOTES:1.ALL EXTERIOR WALLS TO BE TYPE 1 U.N.O.2.BLOCK ALL PANEL EDGES3.PROVIDE 3X SILL PLATE4.OFFSET PANEL EDGES5.PROVIDE 1/2" A.B. @ 48" O.C. W/ 1/4" X 3" X 3" PLATE WASHERS6.PROVIDE 1/2" A.B. @ 24" O.C. W/ 1/4" X 3" X 3" PLATE WASHERS7.PROVIDE 1/2" A.B. @ 24" O.C. W/ 1/4" X 3" X 3" PLATE WASHERS8.STUDS SHALL BE SPACED NOT MORE THAN 16" O.C.NAILINGTOP PLCONNECTION8D@ 6" O.C. PNL EDGES8D@ 12"O.C. FIELDBOTTOM PLCONNECTION(2)16D@12" O.C.1,2,5,9LPT5@16" O.C. TO RAKEBOARD & BLOCKINGBETWEEN RAFTERS1 A 2 1 B 22'-0"14'-0" 3 3 2 2 2 1 3'-0"3'-6" 4'-0" 01 A301 01 A301 A 2 1 B 22'-0"14'-0" 01 A301 02 A301 A 2 1 B 22'-0"14'-0" 4 4 44 4 4 01 A301 N 2 UPPER FLOOR FRAMING PLAN SCALE 1/4" = 1'-0" PLANS FRAMING & FOUNDATION S200 ISSUED FOR PERMITDESCRIPTIONDATE COPYRIGHT MOA Architects PC, 2020 All ideas, designs, and plans indicated or represented by these drawings are owned by and are property of Mobile Office Architects PC (MOA) and were created and developed as instruments of service in connection with the specified project. None of such ideas, designs, or plans shall be used for any purpose whatsoever without the written permission of MOA. ARCHITECT MOA DESIGN-BUILD DUSTIN STEPHENS, RA LIC. # 11451 805 722-9083 DSTEPHENS@MO-ARCH.COM OWNER CLARITY MILLER 508 4TH STREET ANACORTES, WA 98221 CLARITYMILLERGOE@GMAIL.COM c MILLER / GOE DETATCHED ADU 508 4TH STREET, ANACORTES, WA 98221 APN P56508 07/13/20 ISSUED FOR PERMIT SEAL & SIGNATURE: N 3 ROOF FRAMING PLAN SCALE 1/4" = 1'-0" N 1 FOUNDATION PLAN SCALE 1/4" = 1'-0" STRUCTURAL NOTES 1 2 3 4 5 6" THICK CONC. EQUIPMENT PAD, SET 2" ABOVE FINISHED GRADE, REINFORCE W/ 6X6 WELDED WIRE MESH, HARD TROWEL SMOOTH TYP. THICKENED SLAB FOOTING: 1'-4" WIDE W/ 2-#5 BARS TOP AND BOTTOM. SEE SECTION DETAILS. SAW CUT CONTROL JOINT IN SLAB, 7/8" DEEP SKYLIGHT OPENING IN ROOF DECK, SKYLIGHT R.O. FITS BETWEEN TYP. FRAMING SPACING FOUNDATION GENERAL NOTES 1. Concrete shall have a minimum specified compressive strength of 3,000 psi at 28 days. The maximum weight of fly ash, other pozzolans, silica fume, slag or blended cements that is included in concrete mixtures for garage floor slabs and for exterior porches, carport slabs and steps that will be exposed to deicing chemicals shall not exceed the percentages of the total weight of cementitious materials specified in Section 19.3.3.4 of ACI 318. Materials used to produce concrete and testing thereof shall comply with the applicable standards listed in Chapters 19 and 20 of ACI 318 or ACI 332. Concrete shall be air-entrained. Total air content (percent by volume of concrete) shall be not less than 5 percent or more than 7 percent. *For garage floors with a steel-troweled finish, reduction of the total air content (percent by volume of concrete) to not less than 3 percent is permitted if the specified compressive strength of the concrete is increased to not less than 4,000 psi. 2. Where a construction joint is created between a footing and a stem wall, a minimum of one vertical No. 4 bar must be provided at not more than 4 feet on center. The vertical bar must extend to 3 inches clear of the bottom of the footing, have a standard hook and extend a minimum of 14 inches into the stem wall. Skagit County policy requires that these vertical bars be placed in the forms prior to the footing inspection and that concrete be cast with bars in place. Rebar with hooks may not be wet-set under Skagit County policy. 3. Foundation plates must be bolted to foundation with not less than 1/2" steel bolts embedded 7" minimum into concrete and spaced not more than 4' apart. There must be at least two bolts per piece with one bolt located between 3 ½" and 12" from each end of each piece. MARK HEADER / BEAM SCHEDULE HEADER / BEAM H1, H2 NOTES H3, H4 RIM BOARD ABOVE ACTS AS HEADER (LVL 1.25 X 9.5) 3.5" X 12" 24F-V4 DF GLULAM HEADER / BEAM NOTES: 1.REFER TO STRUCTURAL CALCULATIONS PACKAGE FOR ADDITIONAL DETAILS ON ADDITIONAL REQUIREMENTS FOR BEARING AREA, BLOCKING, AND ATTACHMENT. 2.REFER TO IRC TABLE 602.7(1) FOR STANDARD MEMBER SIZING. B1 SEE STRUCTURAL CALCULATIONS FRAME DOWN FOR ROUGH OPENING AS REQUIRED 4X10 #2 OR BETTER HEM FIR BEARING # OF KING STUDS 4x6 POST TO HEADER BELOW 2 TRIMMER STUDS EACH SIDE 1 EACH SIDE 2 TRIMMER STUDS EACH SIDE 2 KING STUDS EACH SIDE SEE STRUCTURAL CALCULATIONS H7 4X8 #2 OR BETTER HEM FIR 2 TRIMMER STUDS EACH SIDE 1 EACH SIDE SEE STRUCTURAL CALCULATIONS H5, H6 4X10 #2 OR BETTER HEM FIR 2 TRIMMER STUDS EACH SIDE 1 KING STUD EACH SIDE SEE STRUCTURAL CALCULATIONS pg. 1 of 5 MILLER / GOE DETACHED ADU STRUCTURAL CALCULATIONS PREPARED BY MOA, DUSTIN STEPHENS, ARCHITECT ISSUED FOR PERMIT 07/13/2020 STRUCTURAL DESIGN CRITERIA: Snow Load: 25 psf Seismic Zone: D1 Wind Speed: Ultimate 110mph, Wind Exposure B Assumed Soil Bearing Capacity: 1500 psf Frost Depth: 12” NOTE: REFER AND REVIEW ALL ATTACHMENTS W/ MANUFACTURER DATA AND STRUCTRUAL MEMBER CALCS. pg. 2 of 5 ROOF DEAD LOADS Type R1: Metal Roofing = 2.0 psf Self-Adhered Underlayment = 0.5 psf 23/32” Roof Deck = 2.4 psf 2x10 Roof Framing = 2.5 psf 1.5” Closed Cell Spray Foam Insulation = 1 psf R-30 Mineral Wool Batt Insulation = 2 psf 5/8” Finish Ply = 2.0 psf TOTAL = 12.4 psf, round to 15 psf Type R2: 4” Loamy Soil (wet) = 30 psf Filter Fabric & Drain Matt = 0.25 psf 60 mil EPDM Membrane = 1.0 psf 23/32” Roof Deck = 2.4 psf 2x8 Ripped Roof Framing = 2.0 psf 6” Closed Cell Spray Foam Insulation = 1.5 psf 5/8” Finish Ply = 2.0 psf TOTAL = 39.5 psf, round to 40 psf FLOOR DEAD LOADS Type F1: Hardwood or Tile Finish : 4.0 psf 23/32" Plywood Subfloor = 2.4 psf TJI Framing = 2.8 psf Insulation = 2.0 psf 5/8” Plywood Finish = 2.0 psf TOTAL = 13.2 psf, round to 15 psf pg. 3 of 5 BRACED WALLS - Per Requirements of IRC TABLE 602.10.3(3) – Wall Bracing General Notes: 1. All shear walls factored meet the minimum length requirement by factors shown in IRC Table 602.10.5. 2. Average wall height used in wall height factor for sloping walls. LEVEL ONE: Wall Line A: Provided Braced Wall Lengths = 5’-6” + 5’-6” =11’-0” Total Wall Length = 14’-0” Use Bracing “CS-WSP” per IRC 602.10 Seismic is greater requirement per R602.10.3(1) and R602.10.3(3) = 3.0ft (per IRC R602.10.3(3)), x1.6 (story height, projected from table), All other scaling factors 1.0 or not applicable = 4.8ft required Note: See tall stud lateral analysis in structural member calcs. Refer to RXXX Exception #2 for acceptable wall height up to 18ft, actual average wall height = 15’-8” Provided CS-WSP shear wall length exceeds minimum required. Wall Line B: Provided Braced Wall Lengths = 4’-0” + 4’-3” +4’-7” = 12’-10” Total Wall Length = 22’-0” Use Bracing “CS-WSP” per IRC 602.10 Seismic is greater requirement per R602.10.3(1) and R602.10.3(3) = 8.5ft (per IRC R602.10.3(3)) x1.2 (story height, partial 12’ high wall), all scaling factors 1.0 or not applicable = 10.2 ft required Provided CS-WSP shear wall length exceeds minimum required. Wall Line C : Provided Braced Wall Lengths = 11’-0” + 4’-0” = 15’-0” Total Wall Length = 22’-0” Use Bracing “CS-WSP” per IRC 602.10 Seismic is greater requirement per R602.10.3(1) and R602.10.3(3) = 8.5ft (per IRC R602.10.3(3)) x 1.2 (story height, partial 12’ high wall), all scaling factors 1.0 or not applicable) = 10.2ft required Provided CS-WSP shear wall length exceeds minimum required. Wall Line D: Provided Shear Wall Lengths = 8’-1” + 2’-8” = 10’-9” Total Braced Wall Length = 14’-0” Use Bracing “CS-WSP” per IRC 602.10 pg. 4 of 5 Seismic is greater requirement per R602.10.3(1) and R602.10.3(3) = 3.0ft (per IRC R602.10.3(3), all adjustment factor items 1.0 or not applicable) = 3.0ft required Provided CS-WSP shear wall length exceeds minimum required. Wall Line E: Provided Shear Wall Lengths = 5’-6” + 5’-6” = 11’-0” Total Braced Wall Length = 14’-0” Use Bracing “CS-WSP” per IRC 602.10 Seismic is greater requirement per R602.10.3(1) and R602.10.3(3) = 2.5ft (per IRC R602.10.3(3), all adjustment factor items 1.0 or not applicable) = 2.5ft required Provided CS-WSP shear wall length exceeds minimum required. Wall Line F: Provided Shear Wall Lengths = 11’-0” + 4’-0” = 15’-0” Total Braced Wall Length = 22’-0” Use Bracing “CS-WSP” per IRC 602.10 Seismic is greater requirement per R602.10.3(1) and R602.10.3(3) = 4.0ft (per IRC R602.10.3(3), x 1.2 (story height, partial 12’ high wall), all adjustment factor items 1.0 or not applicable) = 4.8ft required Provided CS-WSP shear wall length exceeds minimum required. Wall Line G: Provided Shear Wall Lengths = 11’-0” + 4’-0” = 15’-0” Total Braced Wall Length = 22’-0” Use Bracing “CS-WSP” per IRC 602.10 Seismic is greater requirement per R602.10.3(1) and R602.10.3(3) = 4.0ft (per IRC R602.10.3(3), x 1.2 (story height, partial 12’ high wall), all adjustment factor items 1.0 or not applicable) = 4.8ft required Provided CS-WSP shear wall length exceeds minimum required. pg. 5 of 5 ROOF RAFTER DESIGN: Refer to attached calculations. UPLIFT RAFTER CONNECTIONS: Per Table R802.11 – 86 lbs per connection required Use (1) Simpson H2.5A at each rafter to top plate connection (495lb allowable uplift) FLOOR JOIST DESIGN: Refer to Framing Plans, attached manufacturer span table, and individual member calculation. Use 9-1/2” Weyerhauser TrusJoist TJI 210 U.N.O. BEAM AND HEADER DESIGN: Refer to framing plans and attached individual member calculations. FOOTING DESIGN – Per Requirements of IRC Table R403.1(1) Refer to Foundation Plan and Details for more information. Soil bearing capacity = 1500lbs/sqft LOFT Member Name Results Current Solution Comments Floor: Joist Typical Passed 1 piece(s) 9 1/2" TJI® 210 @ 16" OC Wall: Headers H5 & H6 Passed 1 piece(s) 4 x 10 Hem-Fir No. 2 ROOF Member Name Results Current Solution Comments Roof: Joist Typical @ Roof Type R1 Passed 1 piece(s) 2 x 8 Hem-Fir No. 2 @ 24" OC Roof: Ridge Beam B1 Passed 1 piece(s) 3 1/2" x 15" 24F-V4 DF Glulam Roof: Joist @ Low Roof (Type R2) Passed 1 piece(s) 2 x 6 Hem-Fir No. 2 @ 16" OC GROUND Member Name Results Current Solution Comments Wall: Header H3 & H4 Passed 1 piece(s) 4 x 10 Hem-Fir No. 2 Wall: Tall Stud @ E & W Walls Passed 1 piece(s) 2 x 6 Hem-Fir No. 2 @ 16" OC Wall: Tallest Stud @ Gable End Passed 1 piece(s) 2 x 6 Hem-Fir No. 2 @ 16" OC Wall: Header H7 Passed 1 piece(s) 4 x 8 Hem-Fir No. 2 Cap Sante ADU JOB SUMMARY REPORT ForteWEB Software Operator Job Notes 7/13/2020 8:27:48 PM UTCDustin R Stephens Mobile Office Architects, PC (805) 722-9083 dstephens@mo-arch.com ForteWEB v3.0 File Name: Cap Sante ADU Page 1 / 10 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)495 @ 3"1198 (2.50")Passed (41%)1.00 1.0 D + 1.0 L (All Spans) Shear (lbs)480 @ 4"1330 Passed (36%)1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-lbs)1609 @ 6' 10 1/2"3000 Passed (54%)1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in)0.185 @ 6' 10 1/2"0.331 Passed (L/859)--1.0 D + 1.0 L (All Spans) Total Load Defl. (in)0.255 @ 6' 10 1/2"0.663 Passed (L/624)--1.0 D + 1.0 L (All Spans) TJ-Pro™ Rating 46 40 Passed ---- System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •A structural analysis of the deck has not been performed. •Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge™ Panel (24" Span Rating) that is glued and nailed down. •Additional considerations for the TJ-Pro™ Rating include: None. • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Total Accessories 1 - Stud wall - SPF 4.00"2.50"1.75"138 367 505 1 1/2" Rim Board 2 - Stud wall - SPF 4.00"2.50"1.75"138 367 505 1 1/2" Rim Board •TJI joists are only analyzed using Maximum Allowable bracing solutions. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)5' 1" o/c Bottom Edge (Lu)13' 6" o/c Dead Floor Live Vertical Load Location (Side)Spacing (0.90)(1.00)Comments 1 - Uniform (PSF)0 to 13' 9"16"15.0 40.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Dustin Stephens, RA Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED LOFT, Floor: Joist Typical 1 piece(s) 9 1/2" TJI® 210 @ 16" OC ForteWEB Software Operator Job Notes 7/13/2020 8:27:48 PM UTCDustin R Stephens Mobile Office Architects, PC (805) 722-9083 dstephens@mo-arch.com ForteWEB v3.0, Engine: V8.1.1.11, Data: V8.0.0.0 File Name: Cap Sante ADU Page 2 / 10 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1603 @ 1 1/2"4253 (3.00")Passed (38%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1544 @ 1' 1/4"3723 Passed (41%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2517 @ 1' 9"4879 Passed (52%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.008 @ 1' 9"0.081 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.013 @ 1' 9"0.162 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"665 939 1604 None 2 - Trimmer - SPF 3.00"3.00"1.50"665 939 1604 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)Continuous Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 3' 6"N/A 8.2 -- 1 - Point (lb)1' 9"N/A 1213 1790 Default Load 2 - Uniform (PSF)0 to 3' 6"1'25.0 25.0 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Dustin Stephens, RA Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED LOFT, Wall: Headers H5 & H6 1 piece(s) 4 x 10 Hem-Fir No. 2 ForteWEB Software Operator Job Notes 7/13/2020 8:27:48 PM UTCDustin R Stephens Mobile Office Architects, PC (805) 722-9083 dstephens@mo-arch.com ForteWEB v3.0, Engine: V8.1.1.11, Data: V8.0.0.0 File Name: Cap Sante ADU Page 3 / 10 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)302 @ 7' 6 1/4"911 (1.50")Passed (33%)--1.0 D + 1.0 S (Alt Spans) Shear (lbs)263 @ 7' 1 1/8"1251 Passed (21%)1.15 1.0 D + 1.0 S (Alt Spans) Moment (Ft-lbs)494 @ 4' 3"1477 Passed (33%)1.15 1.0 D + 1.0 S (Alt Spans) Live Load Defl. (in)0.068 @ 4' 2 5/8"0.312 Passed (L/999+)--1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in)0.125 @ 4' 2 11/16"0.468 Passed (L/898)--1.0 D + 1.0 S (Alt Spans) System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Member Pitch : 12/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (2L/360) and TL (2L/240). •Birdsmouth cut has not been analyzed. •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Birdsmouth - SPF 5.50"5.50"1.50"181 213 394 Blocking 2 - Hanger on 7 1/4" SPF beam 3.50"Hanger¹1.50"147 179 326 See note ¹ Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)Continuous Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger Connector not found N/A N/A N/A N/A •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Snow Vertical Load Location (Side)Spacing (0.90)(1.15)Comments 1 - Uniform (PSF)0 to 7' 9 3/4"24"15.0 25.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Dustin Stephens, RA Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.Member Length : 11' 2 7/8" MEMBER REPORT PASSED ROOF, Roof: Joist Typical @ Roof Type R1 1 piece(s) 2 x 8 Hem-Fir No. 2 @ 24" OC ForteWEB Software Operator Job Notes 7/13/2020 8:27:48 PM UTCDustin R Stephens Mobile Office Architects, PC (805) 722-9083 dstephens@mo-arch.com ForteWEB v3.0, Engine: V8.1.1.11, Data: V8.0.0.0 File Name: Cap Sante ADU Page 4 / 10 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)3223 @ 10 3/4"8181 (5.50")Passed (39%)--1.0 D + 1.0 S (Adj Spans) Shear (lbs)2567 @ 2' 4 1/2"10666 Passed (24%)1.15 1.0 D + 1.0 S (Adj Spans) Pos Moment (Ft-lbs)15937 @ 11' 8"30188 Passed (53%)1.15 1.0 D + 1.0 S (Alt Spans) Neg Moment (Ft-lbs)-111 @ 10 3/4"23270 Passed (0%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.448 @ 11' 8"0.718 Passed (L/577)--1.0 D + 1.0 S (Alt Spans) Total Load Defl. (in)0.751 @ 11' 8"1.077 Passed (L/344)--1.0 D + 1.0 S (Alt Spans) System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/360) and TL (L/240). •Overhang deflection criteria: LL (2L/360) and TL (2L/240). •Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 21' 5 7/8". •Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 11 3/16". •The effects of positive or negative camber have not been accounted for when calculating deflection. •The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Stud wall - SPF 5.50"5.50"2.17"1301 1922 3223 Blocking 2 - Stud wall - SPF 5.50"5.50"2.17"1301 1922 3223 Blocking Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)Continuous Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 23' 4"N/A 12.8 -- 1 - Uniform (PSF)0 to 23' 4" (Front)3' 3 1/2"15.0 25.0 Default Load 2 - Uniform (PSF)0 to 23' 4" (Back)3' 3 1/2"15.0 25.0 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Dustin Stephens, RA Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF, Roof: Ridge Beam B1 1 piece(s) 3 1/2" x 15" 24F-V4 DF Glulam ForteWEB Software Operator Job Notes 7/13/2020 8:27:48 PM UTCDustin R Stephens Mobile Office Architects, PC (805) 722-9083 dstephens@mo-arch.com ForteWEB v3.0, Engine: V8.1.1.11, Data: V8.0.0.0 File Name: Cap Sante ADU Page 5 / 10 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)155 @ 3' 9 1/2"911 (1.50")Passed (17%)--1.0 D + 1.0 S (All Spans) Shear (lbs)116 @ 3' 4"949 Passed (12%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)139 @ 2'921 Passed (15%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.005 @ 2'0.119 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.012 @ 2'0.179 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Member Pitch : 0.25/12 •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Beam - SPF 3.50"3.50"1.50"107 67 174 Blocking 2 - Hanger on 5 1/2" SPF beam 1.50"Hanger¹1.50"102 64 166 See note ¹ •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)3' 10" o/c Bottom Edge (Lu)3' 10" o/c Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger Connector not found N/A N/A N/A N/A •Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Snow Vertical Load Location (Side)Spacing (0.90)(1.15)Comments 1 - Uniform (PSF)0 to 3' 11"16"40.0 25.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Dustin Stephens, RA Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED ROOF, Roof: Joist @ Low Roof (Type R2) 1 piece(s) 2 x 6 Hem-Fir No. 2 @ 16" OC ForteWEB Software Operator Job Notes 7/13/2020 8:27:48 PM UTCDustin R Stephens Mobile Office Architects, PC (805) 722-9083 dstephens@mo-arch.com ForteWEB v3.0, Engine: V8.1.1.11, Data: V8.0.0.0 File Name: Cap Sante ADU Page 6 / 10 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1478 @ 1 1/2"4253 (3.00")Passed (35%)--1.0 D + 1.0 S (All Spans) Shear (lbs)1091 @ 6' 5 3/4"3723 Passed (29%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)2301 @ 4' 3"4879 Passed (47%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.032 @ 3' 9 1/4"0.181 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.071 @ 3' 9 3/16"0.363 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/240). •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Floor Live Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"802 40 676 1518 None 2 - Trimmer - SPF 3.00"3.00"1.50"696 -551 1247 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu)Continuous Bottom Edge (Lu)Continuous Dead Floor Live Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.15)Comments 0 - Self Weight (PLF)0 to 7' 6"N/A 8.2 ---- 1 - Point (lb)3"N/A 181 40 213 Roof Load on Stud (24" o.c. Advanced Framing) 2 - Point (lb)2' 3"N/A 181 -213 Roof Load on Stud (24" o.c. Advanced Framing) 3 - Point (lb)4' 3"N/A 181 -213 Roof Load on Stud (24" o.c. Advanced Framing) 4 - Point (lb)6' 3"N/A 181 -213 Roof Load on Stud (24" o.c. Advanced Framing) 5 - Uniform (PLF)0 to 7' 6"N/A 35.0 --Wall framing above (Dead Load) 6 - Uniform (PSF)0 to 7' 6"2'30.0 -25.0 Low Roof Load, Applies to Header H3 only Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Dustin Stephens, RA Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED GROUND, Wall: Header H3 & H4 1 piece(s) 4 x 10 Hem-Fir No. 2 ForteWEB Software Operator Job Notes 7/13/2020 8:27:48 PM UTCDustin R Stephens Mobile Office Architects, PC (805) 722-9083 dstephens@mo-arch.com ForteWEB v3.0, Engine: V8.1.1.11, Data: V8.0.0.0 File Name: Cap Sante ADU Page 7 / 10 Wall Height: 12' 6"Member Height: 12'O. C. Spacing: 16.00" Design Results Actual Allowed Result LDF Load: Combination Slenderness 26 50 Passed (52%)---- Compression (lbs)394 4296 Passed (9%)1.25 1.0 D + 1.0 Lr Plate Bearing (lbs)394 4383 Passed (9%)--1.0 D + 1.0 Lr Lateral Reaction (lbs)103 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)95 1320 Passed (7%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)308 @ mid-span 1264 Passed (24%)1.60 1.0 D + 0.6 W Total Deflection (in)0.21 @ mid-span 1.20 Passed (L/670)--1.0 D + 0.6 W Bending/Compression 0.27 1 Passed (27%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/120) •Input axial load eccentricity for this design is 16.67% of applicable member side dimension. •Applicable calculations are based on NDS. •A bearing area factor of 1.25 has been applied to base plate bearing capacity. •A 15% increase in the moment capacity has been added to account for repetitive member usage. Supports Type Material Top Dbl 2X Spruce-Pine-Fir Base Dbl 2X Spruce-Pine-Fir Max Unbraced Length Comments 1' System : Wall Member Type : Stud Building Code : IBC 2015 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 10d x 3" Box (End)2 N/A Base Nails 10d x 3" Box (Toe)1 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Roof Live Vertical Load Spacing (0.90)(non-snow: 1.25)Comments 1 - Point (lb)N/A 181 213 Default Load • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (17'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (110), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Spacing (1.60)Comments 1 - Uniform (PSF)Full Length 16.00"21.4 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Dustin Stephens, RA Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED GROUND, Wall: Tall Stud @ E & W Walls 1 piece(s) 2 x 6 Hem-Fir No. 2 @ 16" OC ForteWEB Software Operator Job Notes 7/13/2020 8:27:48 PM UTC Dustin R Stephens Mobile Office Architects, PC (805) 722-9083 dstephens@mo-arch.com ForteWEB v3.0, Engine: V8.1.1.11, Data: V8.0.0.0 File Name: Cap Sante ADU Page 8 / 10 Wall Height: 16' 3"Member Height: 15' 9"O. C. Spacing: 16.00" Design Results Actual Allowed Result LDF Load: Combination Slenderness 34 50 Passed (69%)---- Compression (lbs)180 2578 Passed (7%)1.15 1.0 D + 1.0 S Plate Bearing (lbs)180 4383 Passed (4%)--1.0 D + 1.0 S Lateral Reaction (lbs)130 ----1.60 1.0 D + 0.6 W Lateral Shear (lbs)122 1320 Passed (9%)1.60 1.0 D + 0.6 W Lateral Moment (ft-lbs)512 @ mid-span 1264 Passed (40%)1.60 1.0 D + 0.6 W Total Deflection (in)0.60 @ mid-span 1.58 Passed (L/316)--1.0 D + 0.6 W Bending/Compression 0.42 1 Passed (42%)1.60 1.0 D + 0.6 W •Lateral deflection criteria: Wind (L/120) •Input axial load eccentricity for this design is 16.67% of applicable member side dimension. •Applicable calculations are based on NDS. •A bearing area factor of 1.25 has been applied to base plate bearing capacity. •A 15% increase in the moment capacity has been added to account for repetitive member usage. Supports Type Material Top Dbl 2X Spruce-Pine-Fir Base Dbl 2X Spruce-Pine-Fir Max Unbraced Length Comments 1' System : Wall Member Type : Stud Building Code : IBC 2015 Design Methodology : ASD Lateral Connections Supports Connector Type/Model Quantity Connector Nailing Top Nails 10d x 3" Box (End)2 N/A Base Nails 10d x 3" Box (End)2 N/A •Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly. Dead Snow Vertical Load Spacing (0.90)(1.15)Comments 1 - Point (lb)N/A 80 100 Default Load • ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (17'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (110), Risk Category(II), Effective Wind Area determined using full member span and trib. width. • IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load. Wind Lateral Load Location Spacing (1.60)Comments 1 - Uniform (PSF)Full Length 16.00"20.6 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Dustin Stephens, RA Weyerhaeuser Notes Drawing is Conceptual MEMBER REPORT PASSED GROUND, Wall: Tallest Stud @ Gable End 1 piece(s) 2 x 6 Hem-Fir No. 2 @ 16" OC ForteWEB Software Operator Job Notes 7/13/2020 8:27:48 PM UTC Dustin R Stephens Mobile Office Architects, PC (805) 722-9083 dstephens@mo-arch.com ForteWEB v3.0, Engine: V8.1.1.11, Data: V8.0.0.0 File Name: Cap Sante ADU Page 9 / 10 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)437 @ 1 1/2"4253 (3.00")Passed (10%)--1.0 D + 1.0 S (All Spans) Shear (lbs)337 @ 10 1/4"2918 Passed (12%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)765 @ 3' 9"3247 Passed (24%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.022 @ 3' 9"0.181 Passed (L/999+)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.050 @ 3' 9"0.313 Passed (L/999+)--1.0 D + 1.0 S (All Spans) System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD •Deflection criteria: LL (L/480) and TL (L/5/16"). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Total Accessories 1 - Trimmer - SPF 3.00"3.00"1.50"249 188 437 None 2 - Trimmer - SPF 3.00"3.00"1.50"249 188 437 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)7' 6" o/c Bottom Edge (Lu)7' 6" o/c Dead Snow Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments 0 - Self Weight (PLF)0 to 7' 6"N/A 6.4 -- 1 - Uniform (PSF)0 to 7' 6"2'30.0 25.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Dustin Stephens, RA Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. MEMBER REPORT PASSED GROUND, Wall: Header H7 1 piece(s) 4 x 8 Hem-Fir No. 2 ForteWEB Software Operator Job Notes 7/13/2020 8:27:48 PM UTCDustin R Stephens Mobile Office Architects, PC (805) 722-9083 dstephens@mo-arch.com ForteWEB v3.0, Engine: V8.1.1.11, Data: V8.0.0.0 File Name: Cap Sante ADU Page 10 / 10 IIiIii20II 0II I 1I 0II I8I I2II80Il 0111,4 !!: , Skagit County Auditor 8/28/2001 Page 1 of 1 12:25:14PM wzvEr Norte THIS SURVEY HAS SEEN PREPARED FOR THE PURPOSE OF LOCATING DE -SCRIBING AND SETTING MONUMENTS TO MARK THE EXISTING BOUNDARIES OF THE LOTS AS SHOWN. THIS SURVEY WAS PREPARED USING A "TOPGON, APL I -A" ROBOTIC TOTAL STATION. ALL BEARINGS ARE ORIENTED TO THAT RECORDOF SURVEY RECORDED IN BOOK 21, SURVEYS, PAGE 10, RECORDS OF SKAGIT COUNTY. SURVEYOR'S CERTIFICATE THIS MAP REPRESENTS A SURVEY MADE BY ME OR UNDER MY DIRECT SUPERVISION IN CONFORMANCE WITH THE REQUIREMENTS OF THE SURVEY RECORDING ACT, IN AUGUST, 2001 AT THE REQUEST OF "ANACORTES 1 0 FOOD B RT F. PARRISH, CERT. NO. 29535 584;° 24'34 "E 112.02' 2 5841°24'34"E 102.00' 12 15 5 REBARS S GAPS LS Ig645 SEE BK. 21, SURVEYS NOO°35'26"E P6. 10 -L100.02' LAND DERIPTIcal THE EAST 18 FEET OF LOT 14 AND ALL OF LOT 15, BLOCK 251, MAP: OF THE CITY OF ANACORTES, ACCORD I N6 TO PLAT THEREOF, RECORDED IN VOLUME 2, OF PLATS, PAGE 4, RECORDS OF SKAGIT COUNTY, WASHINGTON. 5 -• 18 00'-....- 50.00' 58'f °24'54"E 1 14 15 0 No. 512 N841°24'34 "W 30 00' 4TH STET AUDITOR'S CERTIFICATE FE:D FOR RECORD THIS ZS DAY OF 2001 AT /2:45 PM. IN BOOK OF SURVEYS, AT PAGE A T THE REQUEST OF THATCHER, MORRISON & PARRISH, INC _iNDER AUDITOR'S FILE N0. Zeziorzt(Q%' C) r UN Y rA 58q °24'34"E 580.01 ' ��- RESAR 4 CAP, LS 29555 (TYPICAL:) 60.00' 10 GRAPHIC SCALE 20 40 80 ( IN FEET ) 1 inch = :.20 ft. 16.00' — 16 W Pt 0 ino to 0 00 9! N89 ° 24'34 "W 580.02' FOR: F000 BMW SCALE: 1" - 20' APPROVED BY: DRAWN BY:. B No."001 TM&P 1:08-0.15 ATE '8� 15-01 I7 58c1°24'34"E 150.01' rf� z 0 C11 ni 60.00' --‘-- N81 ° 24'34 "W 150.01' N841° 24'34 "W 40.00' REBAR $ CAP LS * ILLEGIBLE 10 20 40.00' 40.00' ---� 410. >r% STREET MONUMENT RECORD OF SURVEY, PREPARED AT THE REQUEST OF ANACORTES 1 DO FOOD BANK MAP OF THE CITY OF ANACORTES, VOL. 2, PLATS, PG. 4 Sift County Washington' Thatcher, Morrison & Parrish, Inc. IOIOB Sixth Street, Anacortes, Washington 98221 360-588 1868 Fax 360-588-1989 email survey@fidalgo.net San Juan County 360-378-2336 June 30, 2020 Clarity Miller 508 4th St. Anacortes, WA 98221 claritymillemoe@gmail.com 360.420.4952 Dear Clarity, N S Thank you for the opportunity to survey your property. This letter is intended to certify that on June 29, 2020 San Juan Surveying located your northwest and southwest property corners as set by Robert Parrish PLS# 29535 per that survey recorded under Auditor's File No. 200108280064, records of Skagit County, Washington. San Juan Surveying set additional 2" x 2" white stakes at said corners and showed you the corner locations. Northwest comer facing South Southwest corner facin North Your business is very much appreciated. Please don't hesitate to contact us if you have any questions or if San Juan Surveying can be of assistance in the future. Sincerely, 44 Robert J. Wilson, PLS Owner / Principal San Juan Surveying 365-D Spring Street • P.O. Box 611 • Friday Harbor, WA 98250 • (360)378-2300 www.sanjuansurveying.com