HomeMy WebLinkAboutPermit File BLD-2020-0590 1605 Tartan Place Y
�- 4` ` .. Cityof Anacortes BLD-2020-0590
_,, *� Invoice/Permit #: BLD 2020 0590
904 6th Street Applied date: 09/29/2020
P.O.Box 547 Issue date: 09/30/2020
Anacortes, WA 98221-0547
=;L,r Expire date: 03/29/2022
(360) 293-1901
Job Address: 1605 TARTAN PL Permit Type: Single Family Alteration/Repair Permit
ANACORTES WA 98221-3127 Project:
APN: P59849
Remarks: INSTALL ROOFTOP SOLAR PV SYSTEM.
Owner: JAMES & MARILYN SOLLERS Contractor: WESTERN SOLAR INC.
Address: 1605 TARTAN PL Address: 4041 HOME RD
ANACORTES WA 98221-3127 BELLINGHAM WA 98226-9158
Phone: (360) 558-9239 Phone: (360) 746-0859
License #:
General Information: Fees:
Building Valuation 3300 Building Permit Fee 97.25
Occupancy Group it-1 Plan Review Fee 63.21
State Building Code Fee Resi 6.50
Total Calculated: 166.96
Deposits/Receipts: 0.00
Total Due: 166.96
The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of
the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or
granting cf this permit is interpreted to allow construction activity during any period of time when such construction is prohibited or restricted by any state or
federal law, or order, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be
valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this
jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of
the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect,
inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or any order, proclamation, guidance or
decision of the Governor. This permit becomes null and void if work or construction authorized is not commenced within 180 days or if construction work is
suspended or abandoned for a period of 180 days at any time after work is commenced. I have read and exa •s application and know the same to
be true and correct.
SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY
1
/
N41Iskitess'
\IPA0101000
4CO3• ./4
Finance Department
020350-0029 Erin W. 09/30/2020 01 :18PM
PERMITS AND INSPECTIONS
WESTERN SOLAR INC,
BLD-2020-0590
Single Family
Alteration/Repair Permit
INSTALL ROOFTOP SOLAR PV
SYSTEM.
issued
2020 Item; BLD-2020-0590
Building Permit Fee 97,25
Plan Review Fee 63,21
State Building Code Fee
Reel 6.50
Mechanical Permit Fees 0.00
Plumbing Permit Fee 0,00
Payment Id: 295516
166.96
Subtotal 166.96
Fee FEE 2.50
Total 169.46
O3FINANCE CREDIT CARD 169,46
MasterCard ************5945
Ref42263622195
Auth:z05436J
8945
• Change due 0.00
Paid by: WESTERN SOLAR INC.
11111111111111111111111011111111111111
Signature: _
Thank you for your payment
COPY
DUPLICATE RECEIPT
•
1 vl � PLANNING,COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT
RESIDENTIAL BUILDING PERMIT APPLICATION
Mailing Address:P.O. Box 547, Anacortes, WA 98221
w Office Location: 904 6`"Street, Anacortes WA 98821
` �-" Phone: (360) 293-1901, Fax: (360) 293-1938
i-
PLEASE REFER TO THE RESIDENTIAL BUILDING PERMIT CHECKLIST BELOW FOR SUBMITTAL REQUIREMENTS
PROJECT ADDRESS(Street,Suite#): 1605 Tartan PL Parcel(s)#:P59849 I
Subdivision/Lot#: Project Valuation: $ I
3300
APPLICANT:Cheryl Beadle/Western Solar Inc. Phone:360-746-0859 Fax: 1
j Address(Street,City,State,Zip): E-Mail Address:cheryl@westernsolarinc.com '
4041 Home Rd.,Suite A.Bellingham,WA 98226
PROPERTY OWNER: Marilyn Sollers Phone:360-746-0859 Fax:
Address(Street,City,State,Zip):1605 Tartan FL,Anacortes,WA 98221 E-Mail Address:jandm_sollers@frontier.com
CONTACT PERSON:Cheryl Beadle Phone:360-746-0859 Fax:
Address(Street,City,State,Zip): E-Mail Address:cheryl@westernsolarinc.com
4041 Home Rd.,Suite A,Bellingham,WA 98226
LENDING AGENCY: Phone: Fax:
I
Address(Street,City,State,Zip): E-Mail Address:
CONTRACTOR:*Western Solar Inc. Phone:360-746-0859 Fax: l
I
Address(Street,City,State,Zip): E-Mail Address:
4041 Home Rd.,Suite A,Bellingham,WA 98226 cheryl@westernsolarinc.com ,
r
f Professional License#: Exp.Date:04/25/2022 r
All Contractors&Subcontractors must have a valid City o Anacortes CCWESTES"910J0
business license prior to doing work in the City. Contact the City's Business License#: Exp.Date:
Finance Department at(360)299-1968. 602258981 12/31/2020
PROPOSED WORK: Install Solar PV System
I
r
PROPOSED NEW SQUARE FOOTAGE:
Basement SQ': Finished Basement: ❑ Unfinished Basement ❑
1"Floor SQ': Garage/Carport SQ': r
2nd Floor SQ': Deck/Covered Porch/Patio SQ':
Fire Sprinkler: Yes 0 No 0 Lot Area SQ':
Is construction associated with an accessory dwelling unit? Yes ❑ No 0
I declare under penalty of perjury that the information I have provided on this form/application is true,correct,and
complete,and that I am the property owner or duly authorized agent of the property owner to submit a permit
application to the City of Anacortes.
Print Name: Cheryl Beadle Owner El Agent e (specify): Western Solar Inc.
Signature: .-------- Date: 9' 2 • 2A
Page 1 of 3 1
1
1
1 IMPERVIOUS SURFACE AREA
i
Existing Impervious SQ': New Impervious SQ':
1 _Total Disturbed Land/Soil SQ': Total Proposed: Cut: Fill:
INew hard surfaces(pervious&impervious)
' Land converted from native vegetation to lawn or landscaping SQ':
Land converted from native vegetation to pasture SQ':
NMFCI-IANICAL:
Equipment Type: Appliance/Equipment Information(new and relocated): Total#:
1
s Furnace: Gas#: Elec#: Other#:
Gas Water Heater: #: Location(s):
Heat Pump: Elec#: Other#:
Air Conditioning: Elec#: Other#:
Boiler: Gas#: Elec#: Other#: BTUs:
1 Exhaust Fans: Bath#: Laundry#: Other:
1 _Range Hood: #: Location(s):
1 Fireplace: Gas#: Elec#: Other:#: Location(s):
i
1 Clothes Dryer:/Duct: Gas#: Elec#: Other:#: Location(s):
'• Stove/Range/Oven: Gas#: Elec#: Other:#: Location(s):
Range Hood: Location(s):
Gas Outlet(s): #: Location(s):
Other: #: Location(s):
TOTAL
i PLUMBING FIXTURES:
• Fixture Type(new and relocated): Total#: Fixture Type(new and relocated): Total#:
Water Closet(Toilet): Refrigerator water supply(for water/ice dispenser):
Kitchen Sink: Pressure Reduction Valve/Pressure Regulator:
1 Utility Sink: Water Service Line:
Tub: Water Piping:
Hand Sink: Clothes Washer:
Shower: Electric Water Heater: Tank-less? Yes 0 No 0
Dishwasher: Backflow Prevention Device:
Hose Bib:
• TOTAL OUTLETS: TOTAL OUTLETS:
Page 2 of 3
fJG � PLANNING, COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT
lca
RESIDENTIAL BUILDING PERMIT CHECKLIST
-,',,,-, Mailing411611rAddress:P.O. Box 547, Anacortes, WA 98221
- wy Office Location: 904 6`h Street, Anacortes WA 98821
"�" Phone: (360) 293-1901, Fax: (360) 293-1938
S
Plans shall be of sufficient clarity to indicate the location,nature,and extent of the work proposed,and conform to the
provisions of the adopted International Codes and City Ordinances.
j PERMIT TYPE:
�;' SUBMITTAL REQUIREMENTS: = v' c o °a. o �;
.. The number indicates the number of 2 A ... b n rz
ara
ten„ copies for submittal(if applicable). 4,1 ° f
n aD r 0 0 Aa
M 5 C C a
ul= 0 C C
`- n
r
Residential Building Permit Application 1 1 1 1 1
Site Plan (Drawn to Scale& Surveyed— 2 7 0 ., 7
if applicable) `
Building Plans(Drawn to Scale) 2 2 2 2 2
Reduced Site Plan(11"X 17") 2 2 0 1 1
Reduced Floor Plan(I I"X 17") 2 2 2 2 1
Structural Calculations(if applicable) 2 2 2 2 2
Energy Code Compliance(shown on
plans)
Complete Stormwater Plan 2 2 0 2
13 Elements SWPPP Checklist 2 2 0 2
Landscape Plan 2 2 2
Grading Plan/Cut/Fill 2 2 2
Critical Areas Report(if applicable) 1 I 1 1
Geotechnical Report(if applicable) 1 I I 1
Plan Review Deposit(due upon ✓
• submittal)
1. Handouts and Standard Details may be found on the City's website at www.cityofanacortes.org or can be
obtained at City Hall during normal business hours.
2. Plans/calculation/reports prepared by state licensed architects or professional engineers must be stamped and
signed by the design professional.
3. For details on the Complete Stormwater plan,please see the Residential Stormwater Application Checklist.
Page 3 of 3
• To Be Completed By the Applicant
Project Address: 1605 Tartan PL, Anacortes, WA 98221
Western Solar Inc./Cheryl l Beadle
Project Applicant: ry
Applicant Email:info@westernsolarinc.com Phone No.:360-746-0859
Site Owner Name:Marilyn Sollers
PV system Description: 6.6 kW System with (20) Panasonic 330AC modules.
with integrated Enphase IQ-7X inverters.
Determine if your project is eligible for an over-the-counter Permit(Check Yes or No) Yes No
1. PV System is designed and proposed for a detached single-family house,duplex or y ❑
townhome.
2. PV System is designed for rooftop of house in general compliance with applicable . ❑
codes.
3. Mounting system is engineered and designed for PV.
4. Rooftop is made from light weight material such as shingles. .1;2 ❑
• 5. PV system will be permitted and pre-approved by Labor&Industries Electrical ❑
division.
6. To address uplift, panel are mounted no higher than 18"above the surface of the g ❑
roofing to which they are affixed. Except for flat roofs,no portion of the system
may exceed the highest point of the roof.
7. Total deal load of panels,supports, mountings,race ways,and all other ] ❑ 1°,
appurtenances weight no more than one of the following.IF Yes, indicate which:
o No more than three and one half(3.5 pounds per square foot(PSF)
o Frameless panels on at least 3/12 pitch roof weighing no more than four and
one-half(4.5)PSF
o Frameless panels on at least 5/12 pitch roof weighing no more than five(5.0)
PSF
8. Supports for solar panels are installed to spread the dead load across as many { ❑
roof-framing members as needed to ensure that no point loads in excess of fifty
(50)pounds are created.
9. Attachment to the roof is specified by the mounting system manufacturer. �j ❑
10. Panels are mounted no higher than the roof ridge or apex of roof(applies only toj ❑
pitched roofs).
Comments:
• o By Checking this box, I certify that all of the information provided on this form is correct.
•
If you answered yes to all of the above questions,your PV installation is eligible for an over-the-counter
building permit. To apply please bring in this completed form to our permit center at City Hall for an
over-the-counter permit.
To be Completed By Staff
Project is eligible for over-the-counter permit? ❑Yes ❑ No
614 City of Anacortes Photovoltaic System Permit
Submittal Requirements
. Permit Required: A building permit is required for the installation or replacement of
solar/photovoltaic(PV)systems, including roof top arrays,ground-mounted arrays and PV
water heaters. An electrical permit is required from the State Department of Labor&
Industries.
Single family residence rooftop installations meeting the criteria in the attached checklist are
eligible to obtain a building permit over-the-counter at the permit center in City Hall.
CODES: International Residential Code (Current Edition)
International Building Code (Current Edition)
International Fire Code (Current Edition)
National Electrical Code (Current Edition)
FEES: Building Permits for installations are based on the material cost of the support system
and labor for the installation.
SUBMITTAL REQUIREMENTS FOR PV(OTHER THAN ONLINE OR OVER-THE-COUNTER PERMITS):
1) Permit Application Form A.
2) Site plan showing location of house and array/equipment on lot,with setback
dimensions to property lines.
3) Roof plan showing the array.
4) Manufacturer specifications or the PV panels and mounting hardware. Include the
weight of the equipment.
5) For rooftop systems not conforming to all of the criteria in the attached checklist,
provide a roof framing plan and either:
a) Structural calculations by a WA State Licensed Engineer or other competent person
showing the adequacy of the existing roof structure to support the additional load,
or
b) Documentation showing that the roof structure was substantially overbuilt
compared to prescriptive code requirements.
6) For ground mounted systems provide structural calculations by a WA state licensed
engineer or other competent person showing how the structure meets wind design
requirements for the structure and footings. Note that ground mounted equipment
greater than 36 inches in height must adhere to minimum required property line
setbacks of the applicable zoning district.
NOTE:The purpose of this handout is to assist the public in complying with detailed permit
submittal requirements. It is NOT a complete list of permit or code requirements and
should NOT be used as a substitute for applicable laws and regulations. It is the
responsibility of the owner/design professional to review the submittal for completeness
and applicability to other codes. Only complete applications will be accepted by the City for
review.
Prime Consultants Inc.
dba.Western Solar Inc.
- (20)Panasonic N330E HIT AC Series Black 96ce11,330 Watt Photovoltaic Modules 4041 Home Rd Ste A
• Total System Size:6,600 Watts DC,6.60 kWs Bellingham,WA 98226
Vmp=58.0 V,Imp=5.7 A,Voc=69.7 V,Isc=6.07 A LIC#:WESTES*910J0
— Module Dimensions:41.5"x 62.6"x 1.38"
-- - '-- ,_• Installed as(1)Strings of(12)Modules with Project Manager:
(12)Enphase IQ7X Microinverters in parallel Eric Blatz
• J and(1)Strings of(8)Modules with
(8)Enphase IQ7X Microinverters in parallel 4041 Home Rd Ste A
—L ---. - . Bellingham,WA 98226
Tel:360-224-9839
.' '' '— Installing Electrician:
Module PV Wire with MC4 Connectors Prime Consultants Inc.
dba.Western Solar Inc.
Enphase IQ7 AC Interconnect Cables 4041 Home Rd Ste A
Black-L1,Red-L2 Bellingham,WA 98226
LIC#:WESTES*872DD
Client Name:
Primary PSE Utility Meter Marilyn Sollers
to be changed to Solar Net Meter 1605 Tartan PL
Located Exterior Residence Anacortes WA 98221
— Roof Mounted Junction Box O
Project Size:
6.60 kW PV System
(4)#12 THHN,
1 (1)#12 Ground
(1)20 Amp&(1)15 Amp,240VAC Solar Interconnect Breakers Drawn by:
Circuit 1:(1.31 Amps max output per inverter)x(12 inverters in parallel)=(15.72 A) Lindsey Bear,WSI
(15.72 A)x(1.25 NEC Safety Factor)=(19.65 A Maximum Output Current)
Issue Date:
Circuit 2:(1.31 Amps max output per inverter)x(8 inverters in parallel)=(10.48 A) 9/24/2020
(10.48 A)x(1.25 NEC Safety Factor)=(13.10 A Maximum Output Current)
240VAC Sub-Array
Combiner Panel One Line Diagram vs1
AC Disconnect 200A 240VAC
Initiates Rapid Shutdown Main Panel
Located Interior Residence a_
— (3)#8 THHN, 1
(1)#10 Ground 23
I
All from rooftop junction box 40 Amp,240VAC Solar Interconnect Breaker —
Al combiner conductorsare pulled throughpjunction
tio3/4n boxNT (1.31 Amp Peak Output)x(20 Microinverters)=(26.20 A)
to (26.20 A)x(1.25 NEC Safety Factor)=(32.75 A Maximum Output Current)
raceways per NEC
Notes:
Exterior/Interior DC Conduit Runs
to be labeled as:
"Photovoltaic Conductors" (20) Panasonic N330E HIT AC Series Black 96ce11, 330 Watt Photovoltaic Modules
Main Disconnect to be Identified as: Total System Size: 6,600 Watts DC, 6.6 kWs
"Photovoltaic Power Source" Vmp=58.0 V, Imp=5.7 A, Voc=69.7 V, Isc=6.07 A Prime Consultants Inc.
Module Dimensions: 41.5" x 62.6" x 1.38" dba. Western Solar Inc.
Design meets requirements of: 4041 Home Rd Ste A
WAC 51-54A-0605 Installed per Manufacturer Recommendations Bellingham, WA 98226
Section 605.11.1.1, 605.11.1.2 on roof of residence using flushmount Snap N Rack LIC#: WESTES*910]0
Mounting System installed at 48" on center,
into premanufactured trusses at 24" o.c.
Project Manager:
Eric Blatz
Meets all City of Anacortes Structural Permitting Requirements 4041 Home Rd Ste A
42.99 lbs per solar module x 20 modules = 859.8 lbs Bellingham, WA 98226
18.04 sqft per solar module x 20 modules = 360.8 sqft Tel: 360-224-9839
Panasonic 330W AC Modules 859.8 lbs / 360.8 sqft = 2.38 lbs/sqft.
Installing Electrician:
Prime Consultants Inc.
dba. Western Solar Inc.
4041 Home Rd Ste A
Bellingham, WA 98226
LIC#: WESTES*872DD
18" setbacks from roof hip
, Client Name:
, �` `4 f= Marilyn Sailers
'\ \ �\ +'e' /// /j/% 1605 Tartan PI
-441 / Anacortes, WA
98221
\ i i /' Project Size:
� ��- / ,J/ 6.6 kW PV System
4 ---- \\
A v��, Sales/Designer:
���� A� ///, / Callum McSherry
\ \ \� /
CITY OF ANACGd ES
-_-: % // PLANNING AND BUILb?k ° APT:
N 9 I / / // ,. / APPROVED PLANS
r // // / RQ fp
w E /I,% /// REVIEWED FOR CODE CM3tIR IViiew
PERMIT#: BLD-2020-0590
'44111140
S �/ ADDRESS: Tartan PI
APPROVED BY: 72,< /_j
SUBJECT TO FIELD INSPECTION.APPROVED PL S SHALL NOT
BE ALTERED WITHOUT AUTHORIZA ON.
Notes: Total PV Array Area: 360.8 sqft
Exterior/Interior DC Conduit Runs Total Roof Area: N 3,300 sqft
to be labeled as: % Roof Area of Array: 10.9%
"Photovoltaic Conductors"
Main Disconnect to be Identified as: 33% Rule Applies
"Photovoltaic Power Source" PV System installed with 18" setback Prime Consultants Inc.
from ridges and hips dba. Western Solar Inc.
Design meets requirements of: 4041 Home Rd Ste A
WAC 51-54A-0605 Bellingham, WA 98226
Section 605.11.1.1, 605.11.1.2 LIC#: WESTES*910J0
106' Project Manager:
Eric Blatz
4041 Home Rd Ste A
Bellingham, WA 98226
PSE Utility meter and Tel: 360-224-9839
PV system disconnect Installing Electrician:
Prime Consultants Inc.
dba. Western Solar Inc.
4041 Home Rd Ste A
Bellingham, WA 98226
LIC#: WESTES*872DD
129'
Client Name:
— Marilyn Sollers
1605 Tartan PI
Anacortes, WA 98221
185'
..•. Project Size:
.....• ', '''''' 6.6 kW PV System
• ''�
Sales/Designer:
� Callum McSherry
18"+ ridge setbacks & Issue Date:
18" hip setbacks 9/28/2020
Parcel # P59849
Site Plan
58' Existing Roof SFR: N 3,300 sf
W E Proposed PV Solar Array: 360.8 sf