Loading...
HomeMy WebLinkAboutPermit File BLD-2020-0471 1401 Dakota Avenue • City of AnacortesInvoice/Permit #: BLD-2020-0471 904 6th Street `7."10111111elow- Applied date: 08/11/2020 P.O.Box 547 Issue date: 08/20/2020 Anacortes, WA 98221-.0547 . 1891 Expire date: 02/16/2022 r:. (360) 293-1901 Job Address: 1401 DAKOTAAVE Permit Type: Single Family Alteration/Repair Permit ANACORTES WA 98221-1310 Project: APN: P31725 Remarks: INSTALL A SOLAR PV SYSTEM, ROOFTOP. Owner: MATTHEW & ASHLEIGH GALAMISON Contractor: WESTERN SOLAR INC. Address: 1401 DAKOTA AVE Address: 4041 HOME RD ANACORTES WA 98221-1310 BELLINGHAM WA 98226-9158 Phone: (904) 334-5704 Phone: (360) 746-0859 License #: General information: Fees: Building Valuation 3465 Building Permit Fee 97.25 Plan Review Fee 63.21 State Building Code Fee Resi 6.50 Total Calculated: 166.96 Deposits/Receipts: 0.00 Total Due: 166.96 The issuance or granting of this permit shall not be construed to be a permit for, or approval of, any violation of this Code or any other ordinance or order of the City, of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor of this State. To the extent the issuance or granting cf t Norm t is interpreted to allow construction activity during any period of time en such construction is prohibited or restricted by any state or teaerai lavtiw, or oraer, proclamation, guidance advice or decision of the Governor of this State, this permit shall not authorize such work and shall not be valid. The building official is authorized to prevent occupancy or use of a structure where in violation of this Code, any other City ordinances of this jurisdiction or any other ordinance or executive order of the City, or of any state or federal law, or of any order, proclamation, guidance advice or decision of the Governor. The building official is authorized to suspend or revoke this permit if it is determined to be issued in error or on the basis of incorrect, inaccurate or incomplete information, or in violation of any City ordinance, regulation or order, state or federal law, or.any order, proclamation, guidance or decision of the Governor. This permit becomes null and void if work or construction authorized is not comme -= hin 180 days or if construction work is suspended or abandoned for a period of 180 days at any time after work is commenced. I have read an, -xamined this application and know the same to be true and correct. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISS CITY OF ANACORTES i ' 11�L®ING DEPART f v'ENT '� = INSPECTION CARD ,,,,_ (360) 293-1901 Q (Card tf be on job site a! all times) Job Address: 1401 DAKO- \AVE APN: P31725 Permit #: BLD-2020-0471 issue daa� : 08/20/2020 Permit Type: Single Fami y /- Iteration/Repair Permit Expire ci .: e: 02/16/2022 Remarks: INSTALL A SOLAR PV SYSTEM, ROOFTOP. Applicant: Contractor: Owner: Lender: WESTERN SOLAR INC. WESTERN SOLAR INC. MATTHEW & ASHLEIGH GALAMISON 4041 HOME RD 4041 HOME RD 1401 DAKOTA AVE BELLINGHAM, WA 98226-t 1 E8 BELLINGHAM WA 98226-9158 ANACORTES WA 98221-1310 (360) 746-0859 (360) 746-0859 (904) 334-5704 License #: Inspector's Inspector's inspection Date Initial Comments Inspection Date initial Comments Stormwater BMPs * Insulation*** Site, Soil, & Footings ** Drywall Foundation ** Roofing Perimeter Drains*** Site Drainage i Post Pads ** Stormwater Final AA Plumbing Ground Work ** Building Final **'`* A Do not remove window labels until' Slab Insulation** approved. * Do not clear, grade, or dig before Stormwater Underfloor Framing*** BMPs inspection passes. Exterior Nailing *** Pub c \ forks ** Do not pour concrete until signed off. Rough Plumbing*** Sewer Connection *** Do not cover until signed off., Gas Piping*** Storm Drain Connection *** Do not occupy buikang Rough Ducts & Vents*** Curb Cut beIore final is signed off and Certificate of Occupancy is Fenestration U-Factors A Public Works Final **** Public Works inspector esuscl]- Framing *** Cell 360-293-1920 a 0 )\() -- 0411 ra , COivi u Ni T`r. . E CrNO lC DEVELOPMENT ELOPMENT DEPARTMENT RESIDENTIAL BUILDING PERMIT APPLICATION UG 12020 Mailing Address: P.D. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901, Fax: (360) 293-1938 Y OF ANACORTES PLEASE REFER TO THE RESIDENTL IL BUILDING PERMIT CHECKLIST BELOW FOR SUBMIT L4L REQUIREMENTS PROJECT ADDRESS(Street,Suite 4): 1401 Dakota Ave, Parcel(s)4: P31725 Subdivision Lot#: Project Valuation: S 3465 APPLICANT:Cheryl Beadle/Western Solar Inc. Phone:360-746-0859 Fax: Address(Street,City; State.Zip): E-Mail Address: 4041 Home Rd.,Suite A,Bellingham,WA 98226 Cheryl@westernsolarinc.com PROPERTY OWNER:Ashleigh Galamison Phone:904.334-5704 Fax: Address(Street,City,State,Zip):1401 Dakota Ave,Anacortes,WA 98221 E-Mail Address: a.galamison a©gmail.com CONTACT PERSON:Cheryl Beadle Phone:360-746-0859 Fax: Address(Street,City,State,Zip): E-Mail Address: 4041 Home Rd.,Suite A,Bellingham,WA 98226 Cheryl@westernsolarinc.com LENDING AGENCY: Phone: Fax: Address(Street,City.State,Zip): E-Mail Address: CONTRACTOR:*Western Solar Inc. Phone:360-746-0859 Fax: Address(Street,City,State,Zip): E-Mail Address: 4041 Home Rd.,Suite A.Bellingham,WA 98226 cheryl@westernsolarinc.com Professional License#: Exp.Date:04/25/2022 All Contractors&Subcontractors must have a valid Cityof,4nacortes CCWESTES*910J0 business license prior to doing work in the City. Contact the City's Business License#: Exp.Date: Finance Department at(360)299-1968. 602258981 1 2/31/2020 PROPOSED WORK: Install Solar PV System PROPOSED NEW SQUARE FOOTAGE: Basement SQ': Finished Basement: ❑ Unfinished Basement ❑ 151 Floor SQ': Garage/Carport SQ': 2nd Floor SQ': Deck/Covered Porch/Patio SQ': Fire Sprinkler: Yes ❑ No ❑ Lot Area SQ': Is construction associated with an accessory dwelling unit? Yes ❑ No ❑ I declare under penalty of perjury that the information 1 have provided on this form/application is true, correct,and complete,and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Anacortes. Print Name: Cheryl Beadle Owner 0 Agent a(specify): Western Solar Inc. Signature: - — � _• `' Date: 8r4120 Page 1 of 3 Notes: Exterior/Interior DC Conduit Runs 1 (21) Panasonic N330E HIT AC Series Black 96ce11, 330 Watt Photovoltaic Modules to be labeled as: Total System Size: 6,930 Watts DC, 6.93 kWs "Photovoltaic Conductors" Vmp=58.0 V, Imp=5.7 A, Voc=69.7 V, Isc=6.07 A Main Disconnect to be Identified as: Module Dimensions: 41.5" x 62.6" x 1.38" "Photovoltaic Power Source" Installed per Manufacturer Recommendations Prime Consultants Inc. Design meets requirements of: dba. Western Solar Inc. WAC 51-54A-0605 on roof of residence using flushmount Snap N Rack 4041 Home Rd Ste A Section 605.11.1.1, 605.11.1.2 Mounting System installed at 48" on center, Bellingham, WA 98226 into premanufactured trusses at 24" o.c. LIC#: WESTES*910J0 Meets all City of Anacortes Structural Permitting Requirements 42.99 lbs per solar module x 21 modules = 902.79 lbs Project Manager: 18.04 sqft per solar module x 21 modules = 378.84 sqft Eric Blatz Panasonic 330W AC Modules 902.79 lbs / 378.84 sqft = 2.38 lbs/sqft. 4041 Home Rd Ste A Bellingham, WA 98226 Tel: 360-224-9839 Installing Electrician: 18"I� Prime Consultants Inc. dba. Western Solar Inc. 15° comp 4041 Home Rd Ste A Bellingham, WA 98226 -, LIC#: WESTES*872DD 3,TAI o I• Client Name: 32 comp ' . Ashleigh & Matthew Galamison •0 ‘ 1401 Dakota Ave • •00 Anacortes, WA 98221 - i i ; - - -: - _ __ _ Project Size: 18"V - ._---- __ --- -= -- ---1 6.93 kW PV System Sales/Designer: Callum McSherry ---- -- d f 1 III I Updated Issue Date: in --- � 1 ' 8/19/2020 in=1I PN 43,►/ Roof Overview N w E S Notes: Exterior/Interior DC Conduit Runs to be labeled as: "Photovoltaic Conductors" Main Disconnect to be Identified as: "Photovoltaic Power Source" Prime Consultants Inc. Design meets requirements of: dba. Western Solar Inc. WAC 51-54A-0605 4041 Home Rd Ste A Section 605.11.1.1, 605.11.1.2 Bellingham, WA 98226 LIC#: WESTES*910J0 Total PV Array Area: 378.84 sqft Total Roof Area: N 2,150 sqft Roof Area of Array: 17.6% Project Manager: 33% Rule Applies 1 1 Parcel # P31725 Eric Blatz PV System installed with 18" setback 4041 Home Rd Ste A from idges ® Existing Roof SFR: N 2,150 sf Bellingham, WA 98226 Proposed PV Solar Array: 378.84 sf Tel: 360-224-9839 Installing Electrician: Prime Consultants Inc. dba. Western Solar Inc. /r 120' — or 4041 Home Rd Ste A �' A Bellingham, WA 98226 _ 65 PSE utility meter 11' LIC#: WESTES*872DD & PV system disconnect "` Client Name: Ashleigh & Matthew Galamison 1401 Dakota Ave 30' ► Anacortes, WA 98221 36" eave setbacks - = I Project Size: ,,,,/ / 86 6.93 kW PV System 53' 84'\ ..• ► Sales/Designer: Callum McSherry 18" setbacks 31' from ridges Updated Issue Date: N 8/19/2020 • W E 93'� I Site Plan s ems,,... 85 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT C � RESIDENTIAL BUILDING PERMIT CHECKLIST Mailing Address: P.O. Box 547, Anacortes, WA 98221 .?'101:q ``' Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901, Fax: (360) 293-1938 Plans shall be of sufficient clarity to indicate the location,nature,and extent of the work proposed, and conform to the provisions of the adopted International Codes and City Ordinances. PERMIT TYPE: etftc oa , O^z cc F• SUBMITTAL REQUIREMENTS: cl et o a o. 9 et . The number indicates the number of ° 1 *� n CFO CT n copies for submittal (if applicable). 11 0 ' ,� p io = F o o ty o 0 o C n Residential Building Permit Application I 1 1 1 1 Site Plan (Drawn to Scale & Surveyed— 2 2 0 2 2 if applicable) Building Plans (Drawn to Scale) 2 2 2 2 2 Reduced Site Plan(11" X 17") 2 2 0 1 1 Reduced Floor Plan(11"X 17") 2 2 2 2 1 Structural Calculations (if applicable) 2 2 2 2 2 Energy Code Compliance(shown on plans) Complete Stormwater Plan 2 2 0 2 13 Elements SWPPP Checklist 2 2 0 2 Landscape Plan 2 2 2 Grading Plan/Cut/Fill 2 2 2 Critical Areas Report(if applicable) 1 1 1 1 Geotechnical Report(if applicable) 1 1 1 1 Plan Review Deposit(due upon ✓ submittal) 1. Handouts and Standard Details may be found on the City's website at www.cityofanacortes.org or can be obtained at City Hall during normal business hours. 2. Plans/calculation/reports prepared by state licensed architects or professional engineers must be stamped and signed by the design professional. 3. For details on the Complete Stormwater plan, please see the Residential Stormwater Application Checklist. Page 3 of 3 To Be Completed By the Applicant Project Address: 1401 Dakota Ave, Anacortes, WA 98221 Project applicant:Cheryl Beadle/Western Solar Inc. Applicant Email:cheryl@westernsolarinc.com Phone No.:360-746-0859 Site Owner Name:Ashleigh Galamison PV System Description:6.93 kW system. (21) Pansonic 330AC modules w/integrated inverters Determine if your project is eligible for an over-the-counter Permit(Check Yes or No) Yes No 1. PV System is designed and proposed for a detached single-family house,duplex or z ❑ townhome. 2. PV System is designed for rooftop of house in general compliance with applicable g1 ❑ codes. 3. Mounting system is engineered and designed for PV. ❑ 4. Rooftop is made from light weight material such as shingles. �j ❑ 5. PV system will be permitted and pre-approved by Labor&Industries Electrical ❑ division. 6. To address uplift,panel are mounted no higher than 18"above the surface of the ❑ roofing to which they are affixed. Except for flat roofs, no portion of the system may exceed the highest point of the roof. 7. Total deal load of panels,supports, mountings,race ways,and all other ❑ appurtenances weight no more than one of the following. IF Yes,indicate which: x No more than three and one half(3.5 pounds per square foot(PSF) o Frameless panels on at least 3/12 pitch roof weighing no more than four and one-half(4.5)PSF o Frameless panels on at least 5/12 pitch roof weighing no more than five(5.0) PSF 8. Supports for solar panels are installed to spread the dead load across as many �j ❑ roof-framing members as needed to ensure that no point loads in excess of fifty (50) pounds are created. 9. Attachment to the roof is specified by the mounting system manufacturer. ❑ 10. Panels are mounted no higher than the roof ridge or apex of roof(applies only to 5 ❑ pitched roofs). Comments: By Checking this box,I certify that all of the information provided on this form is correct. If you answered yes to all of the above questions,your PV installation is eligible for an over-the-counter building permit. To apply please bring in this completed form to our permit center at City Hall for an over-the-counter permit. To be Completed By Staff Project is eligible for over-the-counter permit? o Yes o No G, A City of Anacortes Photovoltaic System Permit Submittal Requirements Permit Required: A building permit is required for the installation or replacement of solar/photovoltaic (PV) systems, including roof top arrays, ground-mounted arrays and PV water heaters. An electrical permit is required from the State Department of Labor& Industries. Single family residence rooftop installations meeting the criteria in the attached checklist are eligible to obtain a building permit over-the-counter at the permit center in City Hall. CODES: International Residential Code (Current Edition) International Building Code (Current Edition) International Fire Code (Current Edition) National Electrical Code (Current Edition) FEES: Building Permits for installations are based on the material cost of the support system and labor for the installation. SUBMITTAL REQUIREMENTS FOR PV (OTHER THAN ONLINE OR OVER-THE-COUNTER PERMITS): 1) Permit Application Form A. 2) Site plan showing location of house and array/equipment on lot, with setback dimensions to property lines. 3) Roof plan showing the array. 4) Manufacturer specifications or the PV panels and mounting hardware. Include the weight of the equipment. 5) For rooftop systems not conforming to all of the criteria in the attached checklist, provide a roof framing plan and either: a) Structural calculations by a WA State Licensed Engineer or other competent person showing the adequacy of the existing roof structure to support the additional load, or b) Documentation showing that the roof structure was substantially overbuilt compared to prescriptive code requirements. 6) For ground mounted systems provide structural calculations by a WA state licensed engineer or other competent person showing how the structure meets wind design requirements for the structure and footings. Note that ground mounted equipment greater than 36 inches in height must adhere to minimum required property line setbacks of the applicable zoning district. NOTE:The purpose of this handout is to assist the public in complying with detailed permit submittal requirements. It is NOT a complete list of permit or code requirements and should NOT be used as a substitute for applicable laws and regulations. It is the responsibility of the owner/design professional to review the submittal for completeness and applicability to other codes. Only complete applications will be accepted by the City for review.