Loading...
HomeMy WebLinkAboutPermit File 4507 Blakely Drive r o CITY OF ANACORTL WASHINGTON vc BUILDING DEPARTMENT ock CERTIFICATE OF OCCUPANCY This is to certify that the(Description of Building or Structure): Single Family Residence Located At: 4507 Blakely Drive, STREET&NUMBER Owner: Homestead NW, Inc. Constructed By: Owner OWNER OR CONTRACTOR Bldg.Permit#CON98-0028 Date Of Issue: 2-17-.98 Occ.Group: R3 Use Zone: R2 Has Been Inspected And Occupancy Is Hereby Authorized, 27th This Day Of April 98 79 III ff�� pp AUTHORIZING OFFICIAL SEE REVERSE SIDE FOR SPECIAL REQUIREMENTS. ■ ■ COMBINATION PERMIT CITY OF ANACORTES PERMIT NO. : COM98-0033 P.O. BOX 547 APPLIED: 02/12/98 ANACORTES, WA 98221 ISSUED: 02/17/98 (206) 293-1901 EXPIRES: 02/17/99 SITE ADDRESS: 4507 BLAKELY DR ASSESSOR'S PARCEL NO. : 4699-000-030-0000 PROJECT DESCRIPTION: New single family — OWNER — CONTRACTOR — LENDER HOMESTEAD NW, INC HOMESTEAD NORTHWEST, INC. P.O. BOX 409 P.O. BOX 409 LYNDEN WA 98264 LYNDEN WA 98264 360-354-3366 360.961.3731 360.380.5163 HOMESNI088CF — FEES TYPE OF WORK •NEW AREA (sf) VALU--.$: 78444 Code Amount---- By- Date---- Receipt TYPE OF USE •SF LOT • 6337 REQUIRED SETBACKS---- ESPL $ -100.00 MD 02/17/98 8016 CENSUS CATEGORY •101 1ST FLR • 1166 FRONT • 15 ft PLCK $ 240.50 MD 02/17/98 8016 ZONING 2ND FLR 0 SIDE(1)..: 15 ft PRMT $ 370.00 MD 02/17/98 8016 :R2 BASEMENT • 0 SIDE(2)..: 5 ft PMEC $ 66.50 MD 02/17/98 8016 OCCUPANCY GROUP GAR/CARPORT...: 420 REAR • 20 ft STBC $ 4.50 MD 02/17/98 8016 :R3 •? •? :? : OTHER 0 REQUIRED PARKING-- PPLM $ 111.00 MD 02/17/98 8016 r TYPE OF CONSTRUCTION TOTAL • 0 SEWR $ 3483.00 MD 02/17/98 8016 :5N •? •? :? : NUMBER OF UNITS • 1 ACCESSIBLE.: 0 IMPT $ 400.00 MD 02/17/98 8016 OCCUPANT LOAD STORIES • 1 COMPACT • 0 STRM $ 1126.00 MD 02/17/98 8016 0: 0: 0: 0: BUILDING HEIGHT.: 0 ft IMPRV SURF.: 0 sf INSP $ 50.00 MD 02/17/98 8016 FUEL TYPES BOILERS/COMPRESSORS- DOMES. INCIN •0 :/GAS/ / /: 0-3 HP • 0 COMML. INCIN •0 FURN < 100K BTU: 1 3-15 HP • 0 RELOC/REPAIR...: 0 TOTAL $ 5751.50 FURN >=100K BTU: 0 15-30 HP • 0 CLOTHES DRYERS.: 1 FURN - FLOOR...: 0 30-50 HP • 0 GAS WTR HEATERS: 1 .— NOTES UNIT HEATERS...: 0 50+ HP • 0 STOVE, APPLI...: 1 VENT FANS • 3 AIR HANDLING UNITS-- FIRE LOG/LITE..: 0 VENT SYSTEMS...: 0 <= 10000 cfm.: 0 WOODSTOVES • 0 VENT W/O APPLI.: 0 > 10000 cfm.: 0 OTHER UNITS • 0 EVAP COOLERS...: 0 GAS OUTLETS • 1 HOODS • 1 _ WATER CLOSETS...: 2 WASHING MACHINES: 1 FLOOR DRAINS • 0 BATH TUBS • 2 ELEC WTR HEATERS: 0 WTR PIPING/TREAT: 1 SHOWERS • 0 LAUNDRY TRAYS...: 0 HOSE BIBBS • 2 DISHWASHERS • 1 URINALS • 0 GREASE TRAPS • 0 LAVATORIES • 2 WASTE INTERCEPT.: 0 ADD'L FIXTURES..: 1 KIT SINKS W/DISP: 1 DRINKING FOUNT..: 0 I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all ordinances and laws regulating activities covered by this permit. 6/1" -tea fileCaterr . sued by Applican or Owne s Signature 24 Hour Notice Required For All Inspections com_prmt, Rev: 11/04/93 G W COMPLETE ENGINEERING GEOLOGY a MATERIALS TESTING& INSPECTION SERVICES ! _ r SERVICES, INC. 741 MARINE DRIVE - BELLINGHAM, WA 98225 ❑ (360)733-7318❑FAX(360) 733-7418 FIELD DENSITY/MOISTURE TEST REPORT ♦ SOILS ASTM D2922 PROJECT: Woodridge Development JOB#: T7097 ADDRESS: Anacortes, WA REPORT#: S9 CLIENT: Homestead Northwest TEST DATE: 2-19-98 CONTRACTOR: Client PAGE#: 1 of 1 INSPECTOR: DW COMPACTION OF : Import fill at house pad. Field Data: TEST LOCATION, ' ' DEPTH/' FIELD IN-PLACE LAB COMPACTION COMPACTION # ELEV. MOISTURE DENSITY SAMPLE % % (ft.) (%) (pcf) # ATTAINED REQUIRED 1 Lot#35 See attached plan +.s;o GR 9.6 121.9 914 98 95 2 Lot#35 See attached plan fat-At'Et.Y GR 11.5 125.2 914 100 95 H 3 Lot#35 See attached plan GR 12.5 120.7 914 97 95 4 Lot#35 See attached plan GR 10.6 117.9 914 95 95 5 Lot#37 See attached plan N s o—/ GR 9.0 118.6 914 95 95 6 Lot#37 See attached plan 0LAKali GR 9.8 118.9 914 96 95 7 Lot#37 See attached plan GR 8.8 119.3 914 96 95 8 Lot#37 See attached plan GR 8.5 120.3 914 97 95 Lab Moisture-Density Data: Lab Soil Max.Dry Optimum Retained M-D Sample Type Source Density Moisture on#4 Test Method # (PO O (%) 914 Gravelly Sand AS&G 124.5 9 0 19 ASTM1557-91C Comments: Contractor stated that approximately 2'to 3'of import fill is at each house pad location. Results of tests today are at or above the 95%requirement. Copies: Homestead Northwest City of Anacortes r/ Submitted By-Dom,- _8e,nCt f Edt Grant Richardson Ma vials Testing Manager This report shall not be reproduced except in full,without the written approval of Gent Test Services,Inc. The above test results relate only to the sample(or location)tested y50rg `A Dr cuti f 37 Z4-0. 1 11 K---- sci AiL . , rrt, i"IwJ` Daa-q � 5-� / 1-(5 Is T 5 ' (,4- ? , L.O. is L� J , llg ) WOODRIDGE • — .a._..,_-- SCALE 1'020' \ LOT 837 4507 BLAKELY DRIVE BLAKELY 4IvE eil \ -- 6-88,2-1:t E 330.00' SS.Oo'' MO 330.00' .n 15'-0" i \I , / 12' / -'N CLEVELAND N RN RECEIVED �B-A N 0 E 0E Fk p,, :,,i 19St; I1 7 EI�1�,IME1°F�II ra 17 FRENCH DRAIN I (SEE SECTION) L J , LOT 31 20'-0" 1. 330.00'S \ -- S 83`IS' E 330.00' I 55.00' K .« a Op\\�L� �;�aj\ ' LEGAL DESCRIPTION, ��/ LOT 37, PLAT OF WOODRIDGE ESTATES, A Carr/ E Ru / PORTION OF THE NW QUARTER OF THE NE j QUARTER OF SECTION 27, TOWNSHIP 35 N TYPICAL DRAIN SECTION RANGE 1 EAST OF THE W.M., SKAGIT COUNTY 2 WASHINGTON. 3/I•. '