Loading...
HomeMy WebLinkAboutPermit File 4501 Blakely Drive • I`\t Y o CITY OF ANACORTES(L i WASHINGTON ti 9cos-k BUILDING DEPARTMENT CERTIFICATE OF OCCUPANCY This is to certify that the(Description of Building or Structure): Single Family Residence P' Located At: 4501 Blakely Drive STREET&NUMBER Owner: Homestead NW, Inc. Constructed By: OWNER OR CONTRACTOR Bldg.Permit# C0M98-0136 Date Of Issue: 6-29-98 Occ.Group: R3 Use Zone: R2 Has Been Inspected And Occupancy Is Hereby Authorized, Ili This 11th Day Of September 19 98 n yr,.a AUTHORIZING OFFICIAL SEE REVERSE SIDE FOR SPECIAL REQUIREMENTS. fi 4 2OMBINATION C PERMIT CITY OF ANACORTES PERMIT NO. : COM98-0136 P.O. BOX 547 APPLIED: 06/26/98 ANACORTES, WA 98221 ISSUED: 06/29/98 (206) 293-1901 EXPIRES : 06/29/99 SITE ADDRESS : 4501 BLAKELY DR ASSESSOR' S PARCEL NO. : 4699-000-040-0000 PROJECT DESCRIPTION: New single family — OWNER — CONTRACTOR — LENDER HOMESTEAD NW, INC. HOMESTEAD NORTHWEST, INC. P.O. BOX 409 P.O. BOX 409 LYNDEN WA 98264 LYNDEN WA 98264 360-354-3366 360.961.3731 360.380.5163 HOMESN I088CF — FEES TYPE OF WORK -NEW AREA (sf) VALU...$: 109000 Code Amount---- By- Date---- Receipt TYPE OF USE -SF LOT • 5514 REQUIRED SETBACKS---- ESPL $ -100.00 MD 06/29/98 8630 CENSUS CATEGORY •101 1ST FLR • 1049 FRONT • 15 ft PLCE $ 296.08 DID 06/29/98 8630 ZONING 2ND FLR • 569 SIDE(1)..: 8 ft PRNT $ 455.50 MD 06/29/98 8630 :R2 BASEMENT 0 SIDE(2)..: 5 ft PMEC $ 71.00 MD 06/29/98 8630 OCCUPANCY GROUP GAR/CARPORT...: 402 REAR • 20 ft PPLM $ 132.00 ND 06/29/98 8630 :R3 :? :? :? OTHER 0 REQUIRED PARKING-- STBC $ 4.50 MD 06/29/98 8630 - TYPE OF CONSTRUCTION TOTAL • 0 SEWR $ 3483.00 ND 06/29/98 8630 :5N :? :? :? : NUMBER OF UNITS • 0 ACCESSIBLE.: 0 IMPT $ 400.00 ED 06/29/98 8630 OCCUPANT LOAD STORIES • 2 COMPACT • 0 STRN $ 1126.00 MD 06/29/98 8630 . 0: 0: 0: 0: BUILDING HEIGHT.: 0 ft IMPRV SURF.: 0 sf ZNSP $ 50.00 MD 06/29/98 8630 FUEL TYPES BOILERS/COMPRESSORS- DOMES. INCIN •0 :/GAS/ / /: 0-3 HP • 0 COMML. INCIN •0 FURN < 100K BTU: 1 3-15 HP • 0 RELOC/REPAIR...: 0 TOTAL $ 5918.08 FURN >=100K BTU: 0 15-30 HP • 0 CLOTHES DRYERS.: 1 FURN - FLOOR...: 0 30-50 HP • 0 GAS WTR HEATERS: 1 — NOTES UNIT HEATERS...: 0 50+ HP • 0 STOVE, APPLI...: 1 VENT FANS • 4 AIR HANDLING UNITS-- FIRE LOG/LITE..: 0 VENT SYSTEMS...: 0 <= 10000 cfm.: 0 WOODSTOVES • 0 VENT W/O APPLI.: 0 > 10000 cfm.: 0 OTHER UNITS • 0 EVAP COOLERS...: 0 GAS OUTLETS • 1 HOODS • 1 WATER CLOSETS...: 3 WASHING MACHINES: 1 FLOOR DRAINS • 0 BATH TUBS • 2 ELEC WTR HEATERS: 0 WTR PIPING/TREAT: 1 SHOWERS • 1 LAUNDRY TRAYS...: 0 HOSE BIBBS • 2 DISHWASHERS • 1 URINALS • 0 GREASE TRAPS • 0 LAVATORIES • 3 WASTE INTERCEPT.: 0 ADD'L FIXTURES..: 1 KIT SINKS W/DISP: 1 DRINKING FOUNT..: 0 i I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all ordinances and laws regulating activities covered by this permit. Issued y Applican or Owner' s Signature 24 Hour Notice Required For All Inspections com_prmt, Rev: 11/04/93 C) _ , r • BLAKELY DRIVE \ \ \\ NSS'IS' W 330.00'S . \\ 35.56' Ir 329.00' s o \\ 15,-p" 'e-m / \ kI \ 0 1 LOP\EZ \ -Z LOT 'r2k Z 0 • \ l0N \ �N ' \ ' \ FRENCH DRAIN • \ SEE DETAIL \ L \ j o \ RECEIVED \m '' 20'-0" I JUN 0 8 1998 mt 330.00' 1 329.00' BUILDING DEW 1 N SS'IS' W \ 55.00' 0 I LEGAL DESCRIPTION, LOT 40, PLAT OF WOODRIDGE ESTATES, A WOODRIDGE PORTION OF THE NW QUARTER OF THE NE LOT 040 4601 BLAKELY DRIVE QUARTER OF SECTION 27, TOWNSHIP 35 N RANGE 1 EAST OF THE W.M., SKAGIT COUNTY SCALE 1' • 20'-0' WASHINGTON. GEO :Ra., (---) n SERVICES, INC. Engineers,Geologists and WABO Special Inspectors 741 Marine Drive•Bellingham,WA 98225•Phone 360.733.7318•Fax 360.733.7418•email geotest@nas.com FIELD DENSITY/MOISTURE TEST REPORT • SOILS ASTM D2922 PROJECT: Woodridge Development JOB#: T7097 ADDRESS: Anacortes, WA REPORT#: S19 CLIENT: Homestead Northwest TEST DATE: 6-24-98 CONTRACTOR: Client PAGE#: 1 of 1 INSPECTOR: JW COMPACTION OF : Lot#40, 4301 See Map. 11 Co..) B t W `( s Field Data: TEST LOCATION DEPTH/ FIELD IN-PLACE LAB COMPACTION COMPACTION # ELEV. MOISTURE DENSITY SAMPLE % (ft.) (T0) (pcf) #- ATTAINED REQUIRED 1 Southwest Corner GR 8.0 119.7 914 96 95 2 Northwest Corner GR 8.0 118.3 914 95 95 3 Center GR 8.5 119.1 914 96 95 4 Southeast Corner GR 8.1 121.0 914 97 95 5 Northeast Corner GR 7.7 119.4 914 96 95 Lab Moisture-Density Data: I Lab Soil Max.Dry - Optimum Retained M-D I Sample Type Source Density Moisture on#4 Test Method # (pc1) (%) .(%) 914 Gravelly Sand AS&G Pit 124.5 9.0 19 ASTM1557-91C j Comments: Geo Test was on site this date to retest compaction of structural fill. Material was recompacted after rainfall. All tests met 95% compaction requirement. Fill depths varied from 1 foot at the East end of the pad to 3 feet at the West end. Copies: Homestead Northwest City of Anacortes Submitted B Grant Richardson Materials Testing Manager ns,mp x,p This report shall not be reproduced except in full,without the written approval of Geo\Test Sernces,Inc The above test results relate only to the sample(or location)tested ,, r t_� ii.J. ..„ . ., ..,..... , . , • . .1 , .► . .. t 1 i a E . lY -�L-`-� O LJ $• • R : 7. 10, 0„, :'.° 39: ;10t56 : ;i.ot37 ; I II II 1 F I ! 11 I I 11 • 1I I i II 11 IJ±JJte .meeJleaetJ / f ' • / •alliaalle- sie eiglialiasfr Sillseenealr 1 ge NieeePd , 1/ /I • ��., _ _ .4I- .. ,, hccR'SS: Aso eumt:-f Coolepo-cZ', SORu'Scpl ptc€ OI-ot-`f ' 1t f citR : STeNIE- Lam. LoT 40 9 2.3 2$ 4 fTh #.1 As r - 00,-10 >ot—gas L-thiE ,r 41-Q9S-1,1 yP 12' Qt. Pc. • S O ` ` �I