Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File 2018 29th Place
y v `%1 o„ CITY OF ANACORTES WASHINGTON gCQP1� BUILDING DEPARTMENT CERTIFICATE OF OCCUPANCY This is to certify that the(Description of Building or Structure): Single Family Residence LocatedAt: 2019 27th Place STREET&NUMBER Owner: R&M LLP Constructed By: OWNER OR CONTRACTOR Bldg. Permit#: BLD-2005-0577 Date Issued: November 17 , 2005 Occ. Group: R3 Use Zone: R2 Has Been Inspected And Occupancy Is Hereby Authorized. This 27th Day ofApril 20 06 JA HORIZING OFFICIAL SEE REVERSE SIDE FOR SPECIAL REQUIREMENTS. ■ 0530104-1 0004 10/28/2005 002 4 SI Y 0 3Fe rt Fees. o t92 onacortes Permit#: BLD-2005- 0551 904 6th Street Issue date: 10/28/2005 P.O.Box 547 Expire date: 10/28/2006 90 Anacortes, WA 98221-0547 ' 10210,44-- .a (360)293-1901 Job Address: 2018 29TH PL Permit Type: Single Family Residence Permit ANACORTES WA 98221-3870 Project: APN: • Remarks: New single family residence. Owner: R&M LLP Contractor: RONMINN LLC Address: 4620 HICKORY DR Address: 2219 HICKORY DR ANACORTES WA 98221-8729 ANACORTES WA 98221-8730 Phone: (360)661-3594 Phone: (360)293-2596 License#: RONMIL*955CB General Information: Fees: Occupancy Group it-1 Plan Review Deposit 100.00 Use Zone R2 Building Permit Fee 870.50 Lot Area 9941 Plan Review Fee 465.83 1st Floor Square Footage 2873 Mechanical Permit Fees 118.50 Garage Square Footage 644 Plumbing Permit Fee 139.00 Building Valuation 274230 State Building Code Fee 4.50 # Forced Air Furnace<=1,000 1 Sewer Inspection Fee 50.00 #of Bathtubs 2 Storm Drain GFC-Residential 1,126.00 #of Clothes Dryers 1 Sewer GFC-Residential 5,646.00 #of Clothes Washers 1 Park Impact Fee 615.00 #of Dishwashers 1 Traffic Impact Fee 900.00 #of Gas Fireplace 1 Total Calculated: 10,035.33 #of Gas Piping 1 Deposits/Receipts: 100.00 #of Gas Water Heaters 1 #of Water Piping 1 Total Due: 9,935.33 #of Hose Bibbs 2 #of Kitchen Sinks 1 #of Lavatories 5 #of Showers 1 #of Ventilation Fans 6 #of Water Closets 3 i THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULA NO-6 NSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. c OF OWNER OR AUTHORIZED AGENT ISSUED BY Como aro : li/C Giae-'&7 4cb/ Anote re 0oi37 .2‘7TrNP/ C /0 �17� aSr Cr / N , SO r I ) 1 . f _____________________ ti Sep , . if I e >f, I, ® . ' 5 C' cp 1f� crra t 4y 005986 $137.33 0.1 0 ., City of Anacortes Permit#: BLD-2005-0720 904 6th Street Issue date: 09/16/2005 `!,.iyletorior Z. P.O.Box 547 Anacortes, WA 98221-0547 Expire date: 09/16/2006 Job Address: 2018 29TH PL Permit Type: Foundation Permit ANACORTES WA 98221 Project: APN: Remarks: Construct foundation only for a single family residence under permit BLD-2005-0551 Owner: R&M LLP Contractor: RONMINN LLC Address: 4620 HICKORY DR Address: 2219 HICKORY DR ANACORTES WA 98221-8729 ANACORTES WA 98221-8730 Phone: (360)661-3594 Phone: (360)293-2596 License#: RONMIL*955CB General Information: Fees: Building Valuation 10000 Building Permit Fee 80.50 Plan Review Fee 52.33 State Building Code Fee 4.50 Total Calculated: 137.33 Deposits/Receipts: 0.00 Total Due: 137.33 THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REG, G CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. SIGNATURE IGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY - ---- -- 0520F,04-1 0004 07/25/2005 002 4 11 f Pet-Di �� 005aL6 1100.00 f j ` kst1,"�a w"CI'mo'"}� F y '. . a .�� F �$ �` xk K � a "Xe f: :9-t., r4,',-: .- "5^'3` t:,3,`` s�A S �.: try:, c-- „.:-v;a' --:, :tr e�.''��'"`'dZ' � e� ' t `� ' '� `d. a. »�� z . ":" ^y�` ,�"pk ?z ' t. Y"",' i 9 -,, r Y dvi r �Ca" �, �- F3' � � �. �.xc Vi );,xt�' � `` ' 1 9Cri It"1!!'L' ....kl i I e.,�' FRio 37.2- t V?'.4-zeIIr- - r:A-s `I� Site Address: a r t Q, ,jh PEACE _ _ Parcel No.: 1 Lot: t '1 Block: Div: Addition: rfl:IP-7:7;71fs =�ts� <f'tz `� '�`:� � a rd �� u� -'�tn� ,-. 3.�'�a �*�e.�,'`��a �c_`R� Z#',� .��� b�.....,�5-ra �� `'�3a-,s . a . �!ems-, r f : �,'.-„ a..5: Name Name Name a i-'M LLT le Cel.e.-tcrTtick Ot)CO10 1 Li-C Mailing Address Mailing Address Mailing Address LIA-2.0 i-tic rr e V De_ 1}fm90 \-k c ce ? DC.. City: State: Zip: City: State: Zip: City: State: Zip: .AtJACOe-F51 WA gPi71.l n Patifs, LJ1a 98ZZI Contractor Lic.No.:k CC.tl e CiP"1Aeti, Phone No.: &lcPhone No.: Phone No.:L 1A.3591Fxp Date: Contact Person: Phone No.: �e..� � ��`, 'kE,,, -_ �ttteASN'Di .a*i h. Cz1 t ,,. re,4 }'.`S f a-2,t41 'T .. 1 Y (Check One) N ^! C l Single Family: X Multi Family: Apartment:_ Condominimum:_Senior Housing._ Retail:_Office: Restaurant:_ �� Manufacturing: Storage: Bank:_Assembly:_Accessory:_Automotive Repair: Other(Specify) \p N-D \ DESCRIPTION OF WORK: V a x€z- .a=n .. '�:r.- - .Szr H � c��i, �'�aw�:..."*'1r^�.xs....�'.�3�',LL`ciEx..,,Ntts.�.4Tt��'eG`�k�'P,�'�. 5��-n._-r,...__>r rY.a.:...-�.-G-?:��..,�..hF�t."•+..�.r Ttrkk.7x- �s�'33',,,�-"' .tS�e^irY:aaxra� . � � i Street Setback d D R. 2id Floor: se (Circle Yor N) In Side Setback ' 6' ft. 3`d Floor: sf. Shoreline/Wetlands Y rd Side Setback /D' ft. Basement sf. Water on/Adj.To Property Y - tear Setback 'jO' ft. Occ.Group: V.--3 Soils Report Y Jse Zone: Carport Area: sf. Sensitive Area Y 0 Cype of Constructin,Ltg _ Garage Area: sf. Latecomers Agreement Y (81 .ot Area: 9,95) sf. No.of Stories: .I I Mae, Fire Hydrant(250 Feet) n N S. Jo.of Dwellings- t Building Height: IS' INS-}- Variance Y iJN eot Covereee' gi % Deck Area: sf. Covenant 7) N 51 Floor Q879-,_ sf 01o,c1.¢) l, 2 Flood Zone X A AE VE 'reject Valuation(Labor and Material Cost): �I I 2 Jt) HIS APPLICATION IS RECEIVED BY THE BUILDING OFFICIAL UNDER 771E PROVISIONS OF THE UNIFORM BUILDING CODE,AND SHALL EXPIRE BY LIMITATION ND BECOME NULL AND VOID IF PERMIT IS NOT OBTAINED WITHIN 180 DAYS OF THIS APPLICATION. BY AFFIXING MY SIGNATURE I HEREBY CER7IFYTHATI M TIE LEGAL OWNER OF THE PROPERTY FOR WHICH THIS APPLICATION IS ISSUED OR AN AUTHORIZED AGENT OF THE OWNER. ALL PROVIS101VS OF LAWS ND ORDINANCES GOVERNING S TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT,INCLUDING CAT I S FOR INSPECTIONS.SP IGNA LURE: DATE: 7 ! is/oS 6)J- Noes- D SS.) 6 ' Ism► `�`l3i. 3� n Ceraa �s.L' „ S e a ¢ a SITE ADDRESS: 4),01r� 29m PLACEASSESSOR'S NO.: LOT: 1-1 BLOCK: ADDITION: Name: (`l1 L T Name: Re_ uss I nN�01• CON3SV LLG• Mailing Address: y(o ! kuCc _�' 02. Mailing Address:Yla20 City: Ft3AC e6.5 State: WA Zip:gg,ZZl City: is State: CiA Zip: f3ZZ1 PhoneNo.: 3600 • (9(ol •.�S9y Phone No.: Ida 3S H Contractors License No.: NC.C4.112C1.%I G NO: Type of Fixture NO: Type of Equipment 3 Water Closet 1.5 OFF Air Cond.Unit HP z Bathtub Refrigeration Unit HP Shower 2.5 GPM Boiler BTTm R Dishwasher 2.5 GPM Forced Air System BTu 5 Lavatory 2.5 GPM Floor Furnace Kitchen Sink 2.5 GPM Wall Heater I Clothes Washer < Clothes Dryer Urinal i.o GPM S Ventilation Fan Drinking Fountain Range Hood Floor Sink or Drain Air Handling Unit cFM Slop Sink Pre-Manf. Stove or Fireplace V Water Piping S Gas Fireplace Hose Bibs ( Gas Water Heater Back Flow Prevention Device Gas Piping Other(Describe) Other(Describe) GAS: ELEC: OTHER: r1S APPLICATION IS RECEIVED BY THE BUILDING DEPARTMENT UNDER THE PROVISIONS OF THE UNIFORM PLUMBING AND MECHANICAL CODES AND SHALL EXPIRE BY MUTATION AND BE.COMENULL AND VOID IF PERMIT IS NOT OBTAINED WITHIN ISO DAYS OF THIS APPLICATION. BY AFFIXING MY SIGNATURE I HEREBY CERTIFY THAT I AM THE LEGAL OWNER OF THE PROPERTY FOR WHICH THIS APPLICATION IS ISSUED OR AN AUTHORIZED AGENT OF THE OWNER. ALL PROVISIONS OF LAWS AND ORDINANCE GOVERNING THIS TYPE OF WORK WILL BE COMPLETED WITH, WHETHER SPECIFIED HEREIN OR NOT,INCLUDING CALLS FOR INSPECTION. SIGNATURE: 1 ` a�%/;� / DATE: _I 1 ie lQS • i • Residential Energy Code (Simple Form) 2003 Washington State Ventilation &Indoor Air Quality Code 2003 Washington State Energy Code This worksheet is intended to assist you in deciding which methods of construction will be used to meet the requirements of the WA ST VIAQ and WSEC Codes. After completing this form,please add all relevant information to your construction plans. PART 1 Whole-House Ventilation:select one of the following methods. _A. Fresh air will be circulated by the central forced air furnace along with a whole house exhaust fan. A single whole- house exhaust fan,which usually does double duty as a room spot fan,is required and must be controlled by a timer set to operate fan a minimum of 8 hours per day. The CFM capacity of the fan must be measured at 0.25 w.g.and have a maximum sone(noise)rating of 1.5. Fresh air intake ports or ducts are required with this option. (WA VIAQ 303.4.1) The minimum size of the fan is based on the number of bedrooms and the size of the house. For houses up to 3,000 square feet,the following sizes are acceptable: 1 or 2 bedrooms—75 CFM 3 bedrooms—90 CFM 4 bedrooms—105 CFM For other-options contact the Planning&Permit Center. X B. Fresh air will be circulated by the central forced air furnace system. The furnace must have a fresh air intake duct and the blower must be activated by a timer to circulate air daily. An exhaust fan is not required with this system. (WA VIAQ 303.4.2) _C. Fresh air will be supplied by wall or window vent ports in each bedroom,kitchen,living room and other habitable rooms along with a whole-house exhaust fan as described in Option A. (WA VIAQ 303.4.1) _D. A heat-recovery ventilation system.(WA VIAQ 303.4.4) PART 2 Insulation and Windows:select one of the following methods. (WSEC Table 6-1) Glazing% U-factor Ceiling Vaulted Walls Floor Slab _1. (2x4 construction) up to 12% 0.35 R-38 R-30 R-15 R-30 R-10 �2. (2x6 construction) unlimited 0.40 R-38 R-30 R-21 R-30 R-10 If you intend to use 2x4 construction,compute the window glazing percentage of heated floor area to verify that the project falls below the 12%maximum allowed glazing: Total area of windows,skylights and patio doors: Lt.49CA sq.ft. Total heated area: 2812 sq.ft. Total window area divided by total heated area=glazing cQ3 - Updated: August 24,2004 Page 1 of 2 • . CITY OP ANACORTES BUIDLING DEPARTMENT RESIDENTIAL. CHECKLIST• • '(Phis form is to be completed poor to issuing the building permit) - j 1 Site Address: 301 aGl\" PLe>1/4.412_ Date: 8-Y—a S' Contact Person s -^- C2 a Phone No.: (of - 3 S qc f • • Assessors No.: Lot f 7 Block Addition: P * 49-Q. 1 (Building Department Checklist for Completeness) . • OK NA • OK NA 0 ❑ - Fire Department Access ❑ 0 Fire Hydrant Locatedwithin 250 feet e ❑ ❑ Fire Flow Required • 0 ❑ Shoreline or Wetlands ❑ Site Plan ❑ ❑ Covenant Approval ❑ ❑ Variance El •❑ Plat Facts and Findings Compliance 0 D S• Rut v n tyy in Flees ❑ ❑ Fill on Site • 1 R.eccived and Rovievied by: . • Date - . ii (Engineering Department Checklist for Completeness) • • OK NA ` OK NA . . ®. ❑ Water Extension/Meter ❑ Sewer Eatension/Connection ❑ 0 Street Improvements/Sidewalks ' . ❑ Site Drainage Plan - 4 0 Covenant Not to Oppose Future LID . ❑' Latecomers Agreement L] 0 Street Drainage ❑ Driveway location,slope,culvert ©©©© 0 Storm Drain Eatensio • P.eceived and Reviewed by: )` 'C^ .?% C �— Dater 1 4E -°S- [FURTIiER CObmnENTS4•• • Lot She: 9 '14 1 ' Coverage Allowed 347 97 s -z, S-l -7 S � L_ - l " nttaye - -a ---- Dt.c.NiN,,, REVISION DATE 6\ Pc1c> PLEASAN T SLOPE LOT # 17 (—)?t:c; ( ic)_) ANACORTES , WA Z 0c‘i a co _,.., . c„, .., PROPERTY LINE - 78.90' _ / �' J {� . . . . . . . . . . . . . . . . . . . . �� W w oW / Q 3 • O 111111111111 CC W r ti • in CD 10'-0" (4-&- \, � a0 EASEMENT IIIIII W M • N a r LOT 17 (PLAN 0427) • I - I r • • O 1 Y c0 ti to 10' CONC PATIO Q F {. Irl .I�III HI I H I, t I 1t 1 I �,, I � • f Z II "Illy : IrI III nH ill I !' 'I _ (%/ CO •,i 11 I I I 1 I '11 II I 11 I' 11 I, I, } , I T' _ I I ,II I� II .11111i I1 { IIII' . , �,„,:_t•,,r Y II I II l I I -1' I I I' • I I 1 11, I II I I I < co M If ,'� I1111 !, 'I)�1 IIIII ,1, ',' I' _i T'1TYTi'STTTf•tTT I ',I II ',I' 1 I' !,1 'll I I I I H r I {' ' I (D U I { } I, 1 .'ill ' I II I, �I , i 1 Il • dl {III I 11,I, '1i' }I '' IIII , !' O II II , 1 II ' . ,I l I RRQP,oE�? - ,R ' "t"S"]T '� I ♦ FFNN I I IIIII ,, � , fi r I • 1 III I III,III,II, IIII' 111 . i t I { II II 11 Ir III I IIII' II i N ' �i,ili,1�, 111 I I{I1 IIII 1'' ' i,11, I' h rl''II HT ...LA I ' I ':I I, rl I II'i I IIIII 11 Im. ,.� 1 ''I', II :r Ill II Ltin,' il,: rh 11111r 'i III 11 Hill • 1 I1 II 1 1 ' I I , I II I :i I I III w I ICI lI 1 I,. IIII fI IIII _ . }w '= 11,1,, , : {,1 ' It1' II Ih III IIII II ll1II III 111' I`Iy.•I!h ' IIr.,i'•T II I II 'I' 'I IIII '{ \ •F— Jux- Ij rill ri I I'}I II. LI 111 .I ial IIIII r i VI I I II I, I II {I ,I I,' � w _ b w I i II'�1 '", � I II 't', 1 I,II1 ',, I I I! Y' IR '1�1 „1 II• I 1 I III , IIII{ t ' I'] I iI' III ', . ' i ! '' 16- Z. ' ', �,11 + I''I! I1 II rl,ll , 4, I L', II ' : 1 ,II 1 III , , IIII' r1' llll 'I } , If, l{I , I, I' ollrll:ll I i • I I pIl I I I },'� l 1i I, I II ,11 I ' p 11I I ", I 11':I • ' ' ' I {I II , IIIIII -I, II II II II II III ' 't II ' ' II I' .i 11 , IIIII IVII{+ u I t ,l f , II I I'I III I I I 1 I Tit':',i I I11 If 1 1 •:W +H I 'll11 III 1r IIi 1 t i ,I, I it 11 4' I II 1I 5'-0" III'1 �1: i '' III 'I 1 ', IIII I I ' ; SETBACK al + I I 'I L'., I IIII ',,, 'll { ' {i j .........................................l it 1 1 I l l II tl l III I1 I, , ' 111 IIII I„' 1 1 , ,, 1111 1 11 +,i1,1` I tII i1i I IIj1 I I IIII , , II 'I r I '1 I II 1 , ' 'I I ,i 1, I 1 ;., II ....,.. I ' 1"' n r'� , 11'I - I. 1 ,'I II' 11 q' ;. II I h,1 I II I, I I ;I I 4H, ." , :r''''+'TIT I 'i I',. 1 I , I „ 1,11+1 it ! I ' , 11 -i I„I r -rri •r T'I''I'I III', - c+r I , 11 ,1 I p IIIII } L II ;„' , ,, F', .,,, - r II 11 I , . Ir } II I ! I II III it III { I Irl'II 11 { ' 111 F1tl', IIII t t'' I I II 'I i 'I ,I { , ! III' tll al 1 'I III, }III„ I{ '' IvIII �, I. { III,�II � I I II I , I {IJ I I. 11 { 11I,:Iiil to ll,y, II lur j1,Il I '' I I I ' � I ' 1 11 { I I 1 IIII I1 I! , {� y '1jI 11' til ' ;1 11 ' I II i I , I 1 I IIIIIIIr Iry 1111I1r II 1 II II ' I I 11 I r 1 ! IIII i ii ', III '' 11 I { IIIIII {Il' 1:.[I",i4 ' ll IIII! Illtll1:1 ' , 'I}IIII I '„ I 1 I'Gl Ih1 II I III II 1 IIII rI ' . +I I It 11 I r ',I I • PirLt y l l'IN I riIII , } n1� I a 11 ''Ifl IIIIII'J tiff III '1 I it lr II I l II 1 I I I I rl I i, I I it ',{ I klt:11II� t', II I I t , , I I li, II • I I I III i1 11, it I } I I} I I IIi t , I I 1 ,; 1 II 1 I I t Oltl 1 I , 1 t llI III d I'll II , I 111, I ,I II li } ll 1 rn :r TrR; IT 'll.{I + 'll III 11 { II li' , 1'i 1 11'I , ,II I11111If1 IIil11 I I 'I Ili r I, III I L u, 111 lrl 1 , 1'I I IL' I I 'I I 1 !' I III Ill, III 1l1 I I, • • rl �'Tr �•i•�I r,'1 r,,�{ II ' n,:I, +II °i I{, 1 , 1, III I III I. . .L II . l � '',I ! II \\\ II it I I I � I �:I \ I II !'� Iti I I rill 1 III it 'I I 1 '" I I , I , L I 1 II ' 1 II I II ' I {'I I I � I II :,_ - .. ,II11 I, IIIIII II I , 1, ' I. I I III'',1111I II IIIII II ', ,! _ I I,1 I,• III li 'Ij I Ii I IIII 1l II uld l III{!I I{ ilt I ,', 1 n N I Ili 1 i, 1 1 U , I, 1 I d I I I , , 1 I 1I,, 0: 10 ' III ' III I , I''I 5-0„ • . I II' l 11 I , }{II II III II. !I ', 1 III II II 'I.-',� I ,, TO BLDG iii p r I 1 11-7 11 I J 1 1 i III I I L `` 11 z'-a a,ilr ri?,Flh? ,II + ., I ll Ij I ➢ S 'els3/4 \c, \ N 9 — m • _ CONC DRIVEWAY\ ——_____ 111 m o \p-gi ••N — w NOTE: PROVIDE 12' WIDE x 20' LONG I 1F°yg DRAINAGE NOTE: z CONSTRUCTION ACCESS W/ 2 1/4" ROCK I P Q • • PROPERTY LINE - 57.90' BASE ® GONG DRIVEWAY LOCATIONS (TYP) TIE ALL FOUNDATION, ROOF DRAIN AND PARKING DRAINS TO . . . • • • - 4' PVC TIGHTLINE TO STORM DRAIN. DRAWING INDEX ^^ EXISTING 5'-0' SIDEWALK EROSION CONTROL NOTE: i� CONTRACTOR TO COVER ALL DISTURBED AND STOCK PILED W EARTH WITH STRAW, STRAW TO REMAIN UNTIL ALL ((�� FIRE CONSTRUCTION IS COMPLETED AND LANDSCAPE IS IN PLACE. ARCHITECTURAL , MHYDRANT v , A1.1 SITE PLAN A2.1 FOUNDATION PLAN & DETAILS JOB: 0427 A3.1 FLOOR PLAN DWN: ALT NORTH SITE PLAN A4.1 ROOF FRAMING PLAN & SHEAR WALL PLAN DATE: 7/18/05 SCALE: = 1/8" = 1' 0" A5.1 WALL SECTIONS 1-4 SHEET NO. 35% LOT COVERAGE A5.2 BUILDING SECTIONS AA—CC & GENERAL NOTES "• ,,,, ,(4......\ po: • LOT SIZE = 9,941 S.F. .....,.....________ 29TH PLACE A6.1 BUILDING ELEVATIONS Al • 1 501-0" RIGHT OF WAY