Loading...
HomeMy WebLinkAboutPermit File 2409 26th Street �.z Y o CITY OF ANACORTES WASHINGTON h 1COH4�.. BUILDING DEPARTMENT CERTIFICATE OF OCCUPANCY This is to certify that the(Description of Building or Structure): SIn("1 L f Qrn.L Ee s4enCr1 � C Located At: C'1+l'7 �W $(CS-Fr • • STREET&NUMBER Owner: NU-"ITh.a_ij%'>`Q.Ckri Constructed By: O I^Tn-1 OWNER OR CONTRACTOR Bldg.Permit#C°t I`Doi 1 Date Of Issue: Occ.Group: K Use Zone: !K 'II Has Been Inspected And Occupancy Is Hereby Authorized, This I 1 Day Off-C.thk 1997 . AUTHORIZING OFFIGAAL SEE REVERSE SIDE FOR SPEC/AL REQUIREMENTS. COMBINATION PERMIT CITY OF ANACORTES PERMIT NO. : COM97-0011 P.O. BOX 547 APPLIED: 01/16/97 ANACORTES, WA 98221 ISSUED: 01/22/97 (206) 293-1901 EXPIRES: 01/22/98 SITE ADDRESS: 2409 26TH ASSESSOR'S PARCEL NO. : 2409 26TH PROJECT DESCRIPTION: New single family I — OWNER — CONTRACTOR — LENDER HOMESTEAD NW, INC. P.O. BOX 409 LYDEN WA 98264 360-354-3366 — FEES TYPE OF WORK •NEW AREA (sf) VALU...$: 70000 Code Amount---- By- Date---- Receipt TYPE OF USE •SF LOT • 7500 REQUIRED SETBACKS---- ESPL $ -100.00 MD 01/22/97 6405 CENSUS CATEGORY •101 1ST FLR • 1166 FRONT • 20 ft PLCK $ 222.95 MD 01/22/97 6405 ZONING 2ND FLR • 0 SIDE(1)..: 5 ft PRMT $ 343.00 MD 01/22/97 6405 :R2 BASEMENT • 0 SIDE(2)..: 10 ft PMEC $ 66.50 MD 01/22/97 6405 OCCUPANCY GROUP GAR/CARPORT...: 420 REAR • 20 ft PPLM $ 97.00 MD 01/22/97 6405 :R3 :? •? :? OTHER 0 REQUIRED PARKING-- STBC $ 4.50 MD 01/22/97 6405 TYPE OF CONSTRUCTION TOTAL • 0 SEWR $ 3333.00 MD 01/22/97 6405 :5N •? •? :? : NUMBER OF UNITS • 1 ACCESSIBLE.: 0 IMPT $ 400.00 MD 01/22/97 6405 - OCCUPANT LOAD STORIES • 1 COMPACT • 0 INSP $ 50.00 MD 01/22/97 6405 . 0: 0: 0: 0: BUILDING HEIGHT.: 0 ft IMPRV SURF.: 0 sf FUEL TYPES BOILERS/COMPRESSORS- DOMES. INCIN •0 :/GAS/ / /: 0-3 HP - 0 COMML. INCIN •0 FURN < lOOK BTU: 1 3-15 HP • 0 RELOC/REPAIR...: 0 TOTAL $ 4416.95 FURN >=100K BTU: 0 15-30 HP • 0 CLOTHES DRYERS.: 1 FURN - FLOOR...: 0 30-50 HP • 0 GAS WTR HEATERS: 1 — NOTES UNIT HEATERS...: 0 50+ HP • 0 STOVE, APPLI...: 1 VENT FANS • 3 AIR HANDLING UNITS-- FIRE LOG/LITE..: 0 VENT SYSTEMS...: 0 <= 10000 cfm.: 0 WOODSTOVES • 0 VENT W/O APPLI.: 0 > 10000 cfm.: 0 OTHER UNITS • 0 EVAP COOLERS...: 0 GAS OUTLETS • 1 HOODS - 1 WATER CLOSETS...: 2 WASHING MACHINES: 1 FLOOR DRAINS • 0 BATH TUBS • 2 ELEC WTR HEATERS: 0 WTR PIPING/TREAT: 0 SHOWERS • 0 LAUNDRY TRAYS...: 0 HOSE BIBBS • 2 DISHWASHERS • 1 URINALS • 0 GREASE TRAPS • 0 LAVATORIES • 2 WASTE INTERCEPT.: 0 ADDIL FIXTURES..: 0 KIT SINKS W/DISP: 1 DRINKING FOUNT..: 0 I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply with all ordinances and laws regulating activities covered by this permit. IMAIssue by App1i ant r 0 4's Signature 24 Hour Notice Required For All Inspections comprmt, Rev: 11/04/93 Gest `;ci\T COMPLETE ENGINEERING GEOLOGY❑MATERIALS TESTING& INSPECTION SERVICES SERVICES, INC. 741 MARINE DRIVE- BEWNGHAM, WA 98225 ❑ (360)733-7318❑FAX(360)733-7418 TEST REPORT FIELD DENSITY/MOISTURE • SOILS ASTM D2922 PROJECT: Cypress Ridge JOB NO: T6090A ADDRESS: Anacortes, WA REPORT NO: S14 CLIENT: Homestead Northwest TEST DATE: 2-3-97 CONTRACTOR: Client PAGE: 1 of 1 D'10 � �'� TECHNICIAN: JM PERMIT #: COMPACTION OF: Lot #54 Import Fill at House Footings. FIELD DATA: TEST DEPTH/ FIELD IN-PLACE LAB COMPACTION PERCENT NO. LOCATION ELEV. MOISTURE DRY DENSITY SAMPLE ATTAINED REQUIRED FT. PERCENT PCF 1 Lot #54 West Side South End GR 7.2 138.2 646 97 95 2 Lot #54 East Central GR 7.7 136.1 646 96 95 3 Lot #54 North End Central GR 7.4 138.1 646 97 95 LAB MOISTURE-DENSITY DATA: Soil 'Sauna . Maximum Dry Optimum Retained : Moisture-Density Sample: : Type -• . . : .Musky- Moisture on#4 Test Method #: . . Pa - :% • . % • • 646 Gravelly Sand Arne Svenson Pit 142.0 6.0 47 ASTM D1557-C Comments: Lot #54 was recompacted with a 15 ton single drum Hyster. Test's resulted in greater than or equal to the required 95% compaction. copies: Homestead Northwest Submitted By: S City of Anacortes Grant Richardson Materials Testing Manager ow r.oi..m..rpn.,.ewe-Teaaan.r+.amu.ttp This report shall not be reproduced except in full,without the written approval of Geo\Test Services, Inc. The above test results relate only to the sample for location)tested. XT-7 COMPLETE ENGINEERING GEOLOGY 0 MATERIALS TESTING&INSPECTION SERVICES SERVICES, INC. 741 MARINE DRIVE- BEWNGHAM, WA 98225 0 (360)733-7318 0 FAX(360)733-7418 TEST REPORT FIELD DENSITY/MOISTURE • SOILS ASTM D2922 PROJECT: Cypress Ridge JOB NO: T6090A ADDRESS: Anacortes, WA REPORT NO: S13 CLIENT: Homestead Northwest TEST DATE: 1-31-97 CONTRACTOR: Client PAGE: 1 of 1 TECHNICIAN: DW PERMIT #: COMPACTION OF: Lot #54 Import Fill at House Footings. FIELD DATA: TEST DEPTH/ FIELD IN-PLACE LAB COMPACTION PERCENT NO. LOCATION ELEV. MOISTURE DRY DENSITY SAMPLE ATTAINED REQUIRED,. FT. PERCENT PCF 1 Lot #54 North Footing Line GR 9.0 135.0 646 95 95 2 Lot #54 East Footing Line GR 8.5 133.4 646 94 95 3 Lot #54 West Footing Line GR 9.6 132.0 646 93 95 4 Lot #54 South Footing Line GR 10.4 135.6 646 96 95 LAB MOISTURE-DENSITY DATA: tab.- Sod • ... • • . ' Source :': • :.._Maximum.Dry Optimum 6fetamed- - Moisture-Density Sample' . . Type -:` - - `: - .. . : density: .Moisture,.._ an#4 •• - Test Method 646 Gravelly Sand Arne Svenson Pit 142.0 6.0 47 ASTM D1 557-C Comments: Results of test #2 and #3 was below 95% compaction. Lot #53 was not ready for testing at the time of our visit. Retest of lot #54 and initial testing of lot #53 is scheduled for 2-3-97 in the afternoon. copies: Homestead Northwest Submitted By: City of Anacortes Grant Richardson Materials Testing Manager o ro_mi.a ei..¢n•.==aaa•-rsoao..v==mpiop This report shall not be reproduced except in full, without the written approval of Geo\Test Services,Inc. The above test results relate only to the sample for location)tested. 0 0 II 26m STREET ' . . ..:, V — f ~ J BOW mac" I I xr rSrE N. • 0,1 / CYPRESS bar i ` Mar Y j :: RIDGE :: \ I . ------7/ G z SITE PLAN °'°" "A" 9[AL 1'-i a-a" r —— __ — — 4, E^ -1 gi 6<WI�111f�\AZ. W keel. I aaBOBBN N BLOW aM ME aB.a),aN.Ls.as.An. .LOT)I y' I • fanwuEue.BLOCK ms.MP IF TIE CITY a A19L'attEN, V y W I?m)a To Fa FEST nl9E..B!(GRlD is MAJI.E)6 RAT.. q CL' O PAGE..nmaw 2.AYa®9 OP sumprO1OY,ANM9GTO1 at.Cr HARTFORD I't; ' "T' BLoa 220 MOW/AACOOMS WO I Wee $ B.fO' Q Lanni.aewC -- 1 MAr• I • "~. • I e \ ` a i i II11 0 r1 \ \ O I I OS i CD ;se OS d * Car Dw L ca. LOT •54 ` r TYPICAL DRAIN SECTION UM LO if , Oa.... Wee a Mw OAN9S t. \ BBrt -, • B BP u m E , l \\\\\ mar In Sat w Mille GRAM coxs.A:d.. MIT , N. ,y ti O YL4�.wvm� 1 1 Olt 1 E\IEapw u A\SiiFu . 1-1lKa 1=RBE D^ES* J