BLD-2020-0007 - FIRE ALARM
rr, •iYt t City of Anacortes Invoice/Permit#: BLD-2020-007 904 6th Street Applied date: 01/07/2020 4 P.O.Box 547 "" 'C • Issue date: 03/06/2020 0; Anacortes, WA 98221-0547 -'ts , ' Expire date: 09/02/2021 (360) 293-1901 Job Address: 907 30TH ST Permit Type: Fire Alarm Permit ANACORTES WA 98221 Project: APN: Remarks: Install a new Fire Alarm system for a Commercial building. Owner: EK TERAASARA LLC Contractor: SECURITY SOLUTIONS NW Address: 905 20TH ST Address: 1619 N STATE ST ANACORTES WA 98221-2504 BELLINGHAM WA 98225-4602 Phone: (360) 770-3701 Phone: (360)734-4940 License#: General Information: Fees: Building Valuation 40000 Building Permit Fee 543.25 Plan Review Fee 353.11 State Building Code Fee Comm 25.00 Total Calculated: 921.36 Deposits/Receipts: 0.00 Total Due: 921.36 Permits and Inspe...-BLD-2020-007-2020 020099-0008 Keri Kna...03/12/2020 02:21 PM 11L59227-SECURITY SOLUTIONS NW hONSBRUCT O glINWF LL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF S.1SySPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I IREAEWtr tft VY THAT I HAVE DEAD AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL PROVISIONS WarlsWiSrAR130104DINANCE§2bNERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE A.IHq,w, PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE P VISIONS OF ANY OTHER STATE OR STRUCTION OR THE PERFORMANCE OF CONSTRUCTION. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSU (; )4 c)—OcIO 0° _GlT I( O PLANNING, COMMUNITY, &ECONOMIC DE ELOPMENT DEPARTMENT --- icitmw pin FIRE ALARM PERMIT APPLICATION \.7� Mailing Address: P.O. Box 547, Anacortes, WA 98221 F- JAN 0 7 2020 I Office Location: 904 6th Street, Anacortes WA 98821 I L.) Phone: (360) 293-1901 PDDL4-49SFIRE ALARM PERMIT CHECKLIST FOR SUBMITTAL REQUIREMENTS ❑ MODIFY EXISTING SYSTEM El INSTALL NEW SYSTEM 0 COMMERCIAL ❑ RESIDENTIAL PROJECT ADDRESS(Street,Suite#): PARCEL(S)#: 907 30TH ST PROJECT VALUATION:40,000 APPLICANT: SECURITY SOLUTIONS NW Phone: 360-734-4940 Address(Street,City, State,Zip): 1619 N STATE ST BELLINGHAM WA Email Address: NATEG@SSNW.CO PROPERTY OWNER: Phone: Address(Street, City, State,Zip): Email Address: CONTACT PERSON: NATE GRAY Phone: 360-734-4940 Address(Street, City, State,Zip): 1619 N STATE ST BELLINGHAM WA Email Address: NATEG@SSNW.CO CONTRACTOR:* Phone: Address(Street, City, State,Zip): Email Address *All Contractors& subcontractors must have a valid CityContractor's License# Exp.Date:4/7/2021 o f SECURSN954JG Anacortes business license prior to doing work in the City. Contact Business License#: Exp.Date: the City's Finance Department at(360)299-1968. 600528172 10/31/2020 Is this work, associated with another project? Yes ❑ No 0 If yes, specify: PROPOSED WORK:FIRE ALARM I declare under penalty of perjury that the information I have provided on this form/application is true,correct, and .7 complete, and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Anacortes. Print Name(DARCY BOERSMA Owner ❑ Agent ❑ (specify): Signature: I Date:1/3/2020 Page 1 of 2 g .G-0 Y 0� PLANNING, COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT p dnik FIRE ALARM PERMIT CHECKLIST kMailingIw Address:P.O. Box 547, Anacortes, WA 98221 ` 111: Office Location: 904 61'Street, Anacortes WA 98821 Phone: (360) 293-1901 Plans shall be of sufficient clarity to indicate the location,nature, and extent of the work proposed, and conform to the provisions of the adopted International Codes and City Ordinances. PERMIT TYPE: b c C 01 m SUBMITTAL REQUIREMENTS: p CD I, CD I The number indicates the number of e) copies for submittal(if applicable). E' ;' C tv �' f D . y 01 AT s Fire Sprinkler Permit Application 1 1 Floor Plan (scaled construction drawings showing): 3 3 o Location of devices and appliances, end of the line devices, conduit wire runs, conduit size and number and size of devices. The zone indication shall be placed adjacent to the appropriate end of the line device o Manual fire alarm & strobes (including installation height) o Fire alarm control panel location,riser location, and control valves o Door hold-open device o Heat and smoke detectors (identify type) duct detectors o Fire alarm tamper Final inspection & approval from the Fire Marshal and Building Inspector is ✓ ✓ required once work is complete—Requested by the applicant Page 2 of 2 Oicles, Dave From: Oicles, Dave Sent: Wednesday, February 26, 2020 10:46 AM To: 'nateg@ssnw.co' Subject: 907 30th St (Salish Inn) Hello Nate, The Fire Marshal has reviewed your permit application for a fire alarm at 907 30th. Here are his requirements that need addressing before I can issue the permit: - Provide exterior horn strobe for fire alarm/water flow - Provide location of horn strobe on the north side of structure - Provide cut sheets for smoke detectors in the units Thank you, Dave Oicles Permit Services Coordinator Planning, Community, & Economic Development City of Anacortes 360-293-1901 1 ' SECURITY 1/2/2020 SOLUTIONS Fire Alarm & 2-Way Communicatior_ Product Subrrttals Salish Inn FILE COPY Security Solutions NW 1-pr:Treffi9w1 ,17] l JAN 0 7 2020 LU PITY OF ANAGORTES 907 30th St Anacortes WA 98221 Bellingham Lock&Safe,A Part of Security Solutions—Locally Owned for Over 100 Years 1619 N. State Street Ph: 360.734.4940 I www.securitysolutionsnw.com Bellingham, WA 98225 Fax: 360.647.9540 Honeywell Addressaole Fire Alarm Control Panels DsILENT. KNIGHT 6808 Addressable Fire Alarm Control Panel v i i i The 6808 is an addressable fire alarm control panel (FACP) that is a direct replacement for the 5808 FACP.The 6808 can be configured to achieve a point capacity of 198 points. It has one built-in signaling line circuit (SLC), which can support 99 System Sensor® (SK) sensors and 99 SK modules or 127 Hochiki® (SD) devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single-point communications. It also has a built-in, dual- line POTS and IP communicator with additional cellular options available. 6808 The 6808 system can be enhanced by adding modules such as the The supports a variety of devices, including the 6860 remote annunciator which also has four programmable function 6860, 5860, and 6855 remote annunciators, 5824 buttons to help automate tasks and reduce time spent at the panel. serial parallel printer interface module (for printing system reports), the 5496 NAC expander, 5895XL SWIFT® wireless compatibility provides options for wireless detection power module, and SK or SD devices. through a Class A mesh network. It is ideal for hard-to-wire locations, buildings where new wiring is not allowed, or to provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard-wired 6808 compatible devices. The 6808 also has a form-C trouble relay, two programmable form-C relays, along with powerful features such as drift compensation, pre- trouble maintenance alert, a built-in sensor test to comply with NFPA 72 calibration testing requirements, and calibration trouble alert. ATUPES & 3 -. NE = Iil 0 Capable of providing ® Convenient • 6860 annunciator with ® Programmable date a 125 software zones up to 198 points to fielcl-upgradeable a 4 x 40 large display setting for automatic and 125 output satisfy smaller firmware ® Four user- and convenient groups for flexible installation needs Built-in dual path programmable buttons Daylight Saving Time design options b Connect up to 17 POTS and IP minimize time spent changes panels on one site with communications with executing complex or ® JumpStart© auto convenient single- optional cellular routine tasks programming reduces point access using the models available for ® guilt-in USB interface installation time SK-NIC Network reliable backup for convenient and Interface Card. reporting quick programming Connected panels can have mixed compatible FACP models SIGNAL LINE CIRCUIT(SLC) PROGRAMMING ORDERING INFORMATION The 6808 SLC loop supports multiple The 6808 system offers several options 6808: Addressable Fire Alarm device types, maintenance alerts, and a to simplify and speed-up programming. Control Panel. (Red cabinet). built-in sensor test to comply with NFPA JumpStart® auto programming 72 calibration testing requirements. minimizes programming required to start COMPATIBLE ANNUNCIATORS a new system. The built-in keypad, or the 6860: 4x40 LCD remote fire INDICATOR LIGHTS 6860, 5860 or 6855 remote annunciator (4 lines and up to • General Alarm (Red): Flashes if in annunciators give you on-site access to 160 characters) per system; four alarm; solid when alarm is silenced current system programming. programmable buttons • Supervisory (Yellow): Flashes if a Programming can also be accomplished 5860: 4x20 LCD remote fire supervisory condition exists; solid using the Windows°-based Honeywell annunciator. 5860 is gray; 5860R is red when supervisory is silenced Fire Software Suite (HFSS) program. 6855: 4x20 LCD remote fire • System Troubles (Yellow): Flashes annunciator SOFTWARE TOOLS 5865-3 or 5865-4: LED annunciators if a trouble condition exists; SKST: Silent Knight Selection Tool solid when trouble is silenced can display up to 30 LEDs (15 red and provides the installer or design architect 15 yellow). The 5865-4 has key switches • System Silenced (Yellow): with a Windows° software system for silence and reset, and a system On when an alarm, trouble or configuration tool to create a detailed Bill trouble LED. supervisory condition has been of Material (BOM) and battery 5880: LED / 10 module has 40 silenced but not yet cleared calculations. programmable LED outputs and eight • System Power (Green): Flashes HFSS: Honeywell Fire Software Suite supervised dry contact inputs which are for AC failure; solid when provides communication and panel useful for custom applications. You can power systems are normal programming, detector status, event use up to eight 5880 modules on one history and additional data. Requires a USER INTERFACE control panel for maximum flexibility. PC running Microsoft° Windows®. Its compact size allows mounting inside The 6808 built-in 4 x 20 annunciator with 80 character LCD display ADDITIONAL INFORMATION the annunciator, or in an accessory and large easy-to-use tactile Twisted-unshielded pair cabinet. touchpad can be used for system wire is recommended. 6808 COMPATIBLE DEVICES AND operation, programming and The 6808 also has 13 preset notification ACCESSORIES maintenance. It has five LEDs for cadence patterns See the data sheets listed below for a complete listing of the SK, SD or SWIFT alarm, supervisory, system trouble, (including ANSI 3.41). devices. system silenced and system power. 53623: SK Devices Data Sheet AGENCY LISTINGS AND APPROVALS 53624: SD Devices Data Sheet System operations include silencing NPFA 13, NFPA 15, NFPA 16, NFPA 70, 350614, 350616 & 350618: SWIFT alarms and troubles, resetting alarms NFPA 72: Central station; remote wireless devices and the display of alarm troubles and Signaling; Local Protective Signaling For a complete and current listing of memory. The system's non-volatile Systems; Auxiliary Protected Premises compatible devices and accessories,visit event historybuffer stores 1,000 www.silentknight.com. Unit; Water Deluge releasing service. Important: You cannot mix SK and SD events for viewing from the built- Suitable for automatic, manual, devices in the same fire alarm system. in or remote annunciator. System waterflow, sprinkler supervisory (DACT operations can be initiated with a non-coded) signaling services mechanical firefighter's key or a • UL Listed: S2766 valid 4-to 7-digit operator's code. • CSFM: 7165-0559:0502 • FDNY: COA# 6246 • FM approved Page 2 of 4 — 351608:B 9/26/2018 SK COMPATIBLE ADDRESSABLE B200S-LF(-IV,-WH): Low-Frequency WSK-WGI: Wireless Gateway DEVICES intelligent sounder base WSK-PHOTO: Wireless Photoelectric smoke SK-ACCLI MATE: Multi criteria B200S-LF: Low-frequency intelligent detector photoelectric smoke detector with thermal sounder base WSK-PHOTO-T: Wireless Multi-criteria 135°F fixed temperature B224RB(-IV,-WH): Relay base photoelectric smoke detector with thermal SK-BEAM: Reflected beam smoke detector B224RB: Relay base detection (135°F fixed temperature) and without test feature B224B1(-IV,-WH): Isolator base B510W 4" base SK-BEAM-T: Reflected beam smoke B224B1: Isolator base WSK-HEAT: Wireless Heat, (135°F fixed detector with test feature temperature) and B510W 4" base SK-CONTROL: Supervised control module SD COMPATIBLE ADDRESSABLE WSK-HEAT-ROR: Wireless heat, ROR SK-CONTROL-6: Six circuit supervised DEVICES (135°F fixed temperature) and B510W 4" control module SD505-6AB:Addressable 6" base base SK-DUCT: Photoelectric duct smoke SD505-6IB: Addressable 6" short circuit WSK-MONITOR:Wireless monitor module detector with extended air speed range isolator base WSK-RELAY: Wireless relay module SK-FIRE-CO: Four criteria fire and carbon SD505-6RB: Addressable 6" relay base W-USB: SWIFT Tools USB transceiver used monoxide detector SD505-6SB:Addressable 6" sounder base for communication with SWIFT devices SK-HEAT: Fixed thermal detector(135°F) SD500-AIM: Addressable input module SK-HEAT-W: Fixed thermal detector (switch input) SBUS ACCESSORIES (135°F), white SD500-ANM: Addressable notification 5496: A 6 amp notification power expander SK-HEAT-ROR: Fixed rate of rise detector module with four power-limited notification (135°F) SD500-ARM: Addressable relay module appliance circuit outputs. SK-HEAT-ROR-W: Fixed rate of rise SD505-DTS-K: Remote test switch and 5883: Relay Interface. Provides 10 Form C detector (135°F), white LED indicator for the SD505-DUCTR relays. SK-HEAT-HT: Fixed high temperature SD505-DUCT:Addressable Duct Smoke 5824: Serial/Parallel Printer Interface thermal detector (190°F) Detector. Module for printer connection. SK-HEAT-HT-W: Fixed high temperature "" SD505-DUCTR: Addressable Duct 5895XL: Power Supply with six FlexputTM thermal detector (190°F), white Detector housing with relay base. circuits, and two Form C relays. Max. 16 per SK-ISO: Fault isolator module system. SD505-H EAT:Absolute temperature heat SK-MINIMON: Mini monitor module 5815RMK: Remote mounting kit. detector. Trip point range from SK-MONITOR: Monitor module 135°F-150°F (0°C-37°C). Dimensions: 10 3/8"W x 10-3/16"H x 3"D SK-MONITOR-2: Dual input monitor SD500-LIM: Addressable Line isolator COMMUNICATION OPTIONS module module SK-MON-10: 10 input monitor module SD500-MIM: Addressable Mini input CELL-CAB-SK: Cellular communicator, * SK-PHOTO: Photoelectric smoke detector monitor module (switch input) metal enclosure with lock/key SK-PHOTO-W: Photoelectric smoke SD505-PHOTO: Photoelectric smoke CELL-MOD: Cellular communicator, plastic detector enclosure* detector, white *Sole path, powered by panel. SK-PHOTO-T: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or with thermal (135°F fixed temperature) dual action pull station IPGSM-4G: Dual path fire alarm SD500-SDM: Addressable smoke detector communicator, cellular and/or IP (primary or SK-PHOTO-T-W: Photoelectric smoke module backup, selectable) detector with thermal (135°F fixed temperature), white SK-IP-2: Remote reporting via the Internet. SK-PHOTOR: Photoelectric detector with AUDIBLE/VISIBLE DEVICES Requires a VisorAlarm° receiver at the central remote test capability These AV devices are all 2-wire. Color: "R" station SK-PHOTO-R-W: Photoelectric detector indicates red; "W" denotes white. For a MISC.ACCESSORIES with remote test capability, white complete listing of Silent Knight AV devices SK-NIC: Network Interface Card. Provides a SK-PULL-SA: Addressable single action go to www.silentknight.com. common communications link for the 6808. pull station CHSRL/CHSWL:Wall chime/strobe SK-NIC-KIT: Installation Accessory Kit SK-PULL-DA:Addressable dual action pull CHSCRL/CHSCWL: Ceiling chime/strobe station SK-FML: Fiber-Optic Multi Mode, CHRL/CHWL:Wall chime transmitter and receiver SK-RELAY: Addressable relay module HRL/HWL:Wall horn SK-RELAY-6: Addressable Six relaycontrol SK-FSL: Fiber-Optic Single Mode module P2RL/P2WL: Wall horn/strobe RBB: Remote battery box accessory cabinet PC2RL/PC2WL: Ceiling horn/strobe for batteries that are too large to fit in the SK-RELAYMON-2:Addressable Dual SRL/SWL:Wall strobe FACP cabinet. Dimensions: 16" W x 10" H x relay/monitor module SK-ZONE: Addressable zone interface SCRL/SCWL: Ceiling strobe 6" D (406mm W x 254mm H x 152mm D). module SPSCRL/SPSCWL: Ceiling speaker/strobe SK-SCK: Seismic Compliance Kit used to SK-ZONE-6: Six zone interface module SPSRL/SPSWL: Wall speaker/strobe securely fasten batteries to the fire panel. B300-6(-IV): 6" base for SK-W Series SPRL/SPWL:Wall speaker B210LP: 6" mounting base SPCRL/SPCWL: Ceiling speaker B501(-BL,-IV,-WHITE): 4"flangeless base B501: 4" Flangeless mounting base SWIFT WIRELESS DEVICES B200S(-IV,-WH): Intelligent sounder base SWIFT is only compatible with System B200S: Intelligent sounder base Sensor(SK) devices. It is not compatible with Hochiki (SD) devices. Page 3 of 4 — 351608:B 9/26/2018 6808 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS (NACs) Flexput®, Honeywell°, Overall Dimensions: 16.36"W x 26.37"H x 3.91"D Four programmable circuits which can be JumpStart®, Silent Knight®, programmed individually as: SWIFT®, and System Shipping Weight: 32 lbs. Sensor°are registered Color: Red NACs: 3A @ 27.4VDC per circuit, power-limited trademarks of Honeywell (with a maximum current of 6A) International Inc. ENVIRONMENTAL Auxiliary Power Circuits: 3A @ 27.4VDC per circuit, 0 120°F (0°C power-limited Hochiki® is a registered Operating Temperature: 32°F to 120°F (0 C to trademark of Hochiki 49°C) Corporation. Microsoft° Humidity: 0 to 93% relative humidity (non- Supports Class B (Style 4) and Class A(Style 6 or 7) and Windows°are condensing) configuration for the SLC registered trademarks of Microsoft Corporation. ELECTRICAL WIRING: See the product manual for wiring details This document is not 6808 Primary AC: 120 VAC @ 60Hz, 3.3A Total intended to be used for Accessory Load: 6A @ 27.4VDC power-limited installation purposes.We Standby Current: 190mA try to keep our product information up-to Alarm Current: 250mA date and accurate.We Battery Charging Capacity: 7 to 35AH cannot cover all specific Battery Size: 7AH to 18AH max. allowed in control applications or anticipate panel cabinet. Larger capacity batteries can be all requirements.All specifications are subject housed in RBB accessory cabinet. to change without notice. For Technical Support, call 800-446-6444. Honeywell Silent Knight 12 Clintonville Road Honeywell Northford, CT 06472 351608 I B 109/18 D SILENT 800-328-0103 ©2018 Honeywell International Inc. KNIGHT !SYSTEM 4 SENSOR® e - _ 5600 Series _ aoatxd Mechanical Heat 7411/4 5601P Detectors System Sensor's 5600 series mechanical heat detectors (PP) offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. ro riate. 135 F 51 Ct. 5621 Features Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both • Multiple configurations for installations: single- and dual-circuit models are available for low- and high- - Single- and dual-circuit models — Fixed temp and combination fixed- temp/rate-of-rise temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of 135°F or 194°F ratings. the fixed/ROR models is restorable to accommodate field-testing. • Plain housing for residential installations (Model 5601P) • Easy-to-use terminal screws Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back • A broad range of back box mounting options: boxes. And these models accommodate four-square back boxes, — Single gang when used with a square to round plaster ring. The reversible — 3.5""and 4""Octagonal mounting bracket permits both flush- and surface-mount back box — 4"square with square to round plaster ring installations. • Reversible mounting bracket Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/ rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. Agency Listings -7I 41/1; vl LISTED APPROVED S2101 3016008 CS630 7270-1653:0167 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number , listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601 P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601P, 5602, 5621, and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage/Contact 6-125VAC /3A Ratings 6-28VDC / 1A 125VDC/0.3A 250VDC /0.1 A Input Terminals 14-22 AWG �� do �()\ � ' i 7 111111111r N\ / O O O O 1 , ,, id/ , s ‘ s ; ' k i ' ' (1(0, . , , / i __________ -. --___I .21‘,----- ., 5601P 5602, 5622 5603, 5623 5604, 5624 5621 Ordering Information Identification Method Temperature UL Protected Spacing - 10 Foot Model Circuit on Exterior Rating Activation Ceiling* 5601P Single None 135°F (57°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194°F (90°C) Fixed Temperature/ Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135°F (57°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. *, --- SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2013 System Sensor. Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com SENSOR' for current product information,including the latest version of this data sheet. www.systemsensor.com SPDS30001 •7/13 -114411 Honeywell SILENT'"6 KNIGHT SK- PHOTO, SK- PHOTO-T, and SK- PHOTOR Intelligent Photoelectric Smoke Detectors The SK-PHOTO is a photoelectric smoke detector, the SK PHOTO T is a photoelectric smoke detector with thermal and SK-PHOTOR is a photoelectric detector with remote test capability. These plug in smoke �- detectors, with integral communication, provide features that surpass • conventional detectors and are for use with the Honeywell Silent Knight series fire alarm control panels (FACPs). SK-PHOTO and SK-PHOTO-T are plug-in type smoke sensors that combine a photoelectric sensing chamber with addressable analog communications. Point ID capability allows each detector's address to be • set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK-PHOTO (BASE INCLUDED) SK-PHOTO and SK-PHOTO-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the SK-PHOTO-T, dual electronic thermistors add 135°F (57°C) thermaltechnology to maximize detection. The SK-PHOTOR is a remote test capable detector for use with the DNR/ DNRW duct smoke detector (not included). COMPATIBILITY SK-Photo, and SK-Photo-T are compatible with the following detector bases: B210LP: 6" base (included) B501: 2 wire base B224RB: Relay base B224BI: Isolator base FFAT `J lES & BENEFITS • Sleek, low-profile ® Superior EMI ® Detector transmits • Plug-in mounting Listed for use in duct design resistance for signal to indicate provides ease of applications ® Base included reliability maintenance is installation ® Rotary address • Reliable analog Simple field cleaning required ® Tamper-proof feature switches for fast communications for for code compliance ® Optional remote LED available on mounting installation annunciator (System bases trouble-free operation • Variety of mounting UL Listed options to meet any Sensor' PN RA100Z) • Age resistant polymer • FM Approved housing application • Dual electronic * Dual LED indicators thermistor design on for360°visibility the SK-Photo-T SK—PHOTO, SK—PHOTO—T and SK—PHOTOR Technical Specifications For a complete listing of all / � compliance approvals and �.-- SLC certifications, please visit �' IN OUT www.silentknight.com. / 1' fai FA t Compatible FACP L I- Microsoft,Windows, and + - + - the Windows Logo are registered trademarks RA100Z(Optional) or trademarks of Microsoft Corporation. Silent Knight®,System MIA Sensor° and Honeywell° ! cI, 4 F - are registered `rj trademarks of Honeywell � International, Inc. This document is not intended to be used for Class A Optional Wiring installation purposes.We ,try to keep our product Wiring SK-Serles Detector Mounting Bases information up-to date and accurate.We cannot cover all specific PHYSICAL ACCESSORIES applications or anticipate Height: 2.0" (5.0 cm) RA100Z: Remote LED annunciator all requirements.All Diameter: 4.1" (10.4 cm) installed in B501 base XR2B: Detector removal tool. A removal and specifications are subject replacement tool for SK series plug-in detectors. to change without notice. ELECTRICAL Includes theT55-127-000 For Technical Support, Operating Voltage: 15-32VDC M02-04-01: Detector test magnet. call 800-446-6444. Standby Current: 300 µA @ 24VDC Maximum M02-09-00:Test magnet with telescoping handle Alarm Current: 6.5mA @ 24VDC max (with LED on) XP-4: Extension Pole for XR2B. Extends from 5 — 15 ft. ENVIRONMENTAL T55-127-000: Detector Removal Head Operating Temperature BCK-200B: Black Detector Kit. For SK series SK-Photo: 32° — 120°F (0°C — 49°C) detectors SK-Photo-T: 32° — 100°F(0°C — 38°C) Humidity: 10% - 93% non-condensing COMPATIBILITY The SK-PHOTO, SK-PHOTO-T and SK-PHOTOR OTHER RATINGS are compatible with the following Honeywell SK-Photo-T Thermal: Fixed temperature set point Silent Knight fire alarm control panels: 135°F (57°C) 6820: Addressable fire alarm control panel Velocity: 0 -4000 fpm (0 — 20 m/sec) 6820EVS:Addressable fire alarm control panel with an emergency mass notification system. INSTALLATION 6808:Addressable fire alarm control panel The SK-PHOTO and SK-PHOTO-T plug into a 6700: Addressable fire alarm control panel compatible Silent Knight series detector bases.The 5700: Addressable fire alarm control panel SK-PHOTOR is a remote test capable detector head 5808: Addressable fire alarm control panel included within the DNR (W) duct smoke detector. 5820XL:Addressable fire alarm control panel ORDERING INFORMATION 5820XL-EVS: Addressable fire alarm control panel SK-PHOTO: Photoelectric smoke detector with an emergency mass notification system. SK-PHOTO-T: Photoelectric smoke detector with thermal (135°F fixed temperture) SK-PHOTOR: Photoelectric detector with remote test capability For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight Hone3ivell 12 Clintonville Road Northford, CT 06472 Doc 350118 I Rev G 111/17 rPl SII,ENT� 800-328-0103 ©2017 Honeywell International Inc. 1114KNIGHT -1911 Honeywell & SILENT' KNIGHT SK-CONTROL Intelligent Notification Module The SK-CONTROL is an addressable notification module for use with Honeywell Silent Knight series fire alarm control panels (FACPs). The SK-CONTROL provides supervised monitoring of wiring to load devices that require an external power supply to operate, such as bells, horns, and l,,Elos strobes. It is capable of Class B (Styles Y) and Class A (Style Z) supervision. ''OEM-�„ J A Q 1/ 340 J, Upon command from the FACP, the SK-CONTROL will disconnect the ' p ,, ,�w. b` may, r,♦.vi W ,. supervision and connect the external power supply across the load device. afrits I '•-r 1 The disconnection of the supervision provides a positive indication to the41 r panel that the control relay actually turned on. The external power supply is '-=: E_ • always relay isolated from the SLC loop, so that a trouble condition on the al► power supply will never interfere with the rest of the system. INSTALLATION SK-CONTROL The SK-CONTROL mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor° PN SMB500) is available from Silent Knight. FEATURES & BENEFITS • Flexible solution for • Polling LED visible ® Rotary address adding notification through the cover switches for fast circuits where needed plate installation • Support for Class B Attractive ivory cover • SEMS screws for easy (style Y) or Class A plate wiring (style Z)wiring UL Listed • Panel controlled status LED that flashes green in normal state and is solid red in alarm SK-CONTROL Technical. Specifications Fora complete listing of all compliance approvals and certifications, please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. Dimensions: 4.5" H x 4" W x 1.3" D (11.4 cm x 10.2 SK-Control: Notification Module Microsoft,Windows,and cm x 3.2 cm) the Windows Logo are ACCESSORIES. registered trademarks ELECTRICAL SMB500: 4" Square Surface Mount Electrical Box or trademarks of Operating Voltage: 15 — 32 VDC CB500: Module Barrier Microsoft Corporation. External Power Supply Silent Knight®, System Alarm Current: 7mA per module; Standby Current: COMPATIBILITY Sensor® and Honeywell® 1.7mA The SK-CONTROL is compatible with the are registered End-of-Line Resistance: 47KQ following Honeywell Silent Knight fire alarm trademarks of Honeywell SLC Standby&Alarm Current: .375mA max. @ 24 control panels: International, Inc. VDC (one communication every 5 sec with 47K 6820: Addressable fire alarm control panel This document is not EOL) 6820EVS: Addressable fire alarm control panel intended to be used for SLC Loop Resistance: 40 ) max. with an emergency mass notification system. installation purposes.We 6808: Addressable fire alarm control panel try to keep our product information up-to ENVIRONMENTAL 6700: Addressable fire alarm control panel date and accurate.We Operating Temperature: 32°F— 120°F(0°C — 5700:Addressable fire alarm control panel cannot cover all specific 49°C) applications or anticipate 5808: Addressable fire alarm control panel Humidity: 10% — 93% non-condensing all requirements.All 5820XL: Addressable fire alarm control panel specifications are subject 5820XL-EVS: Addressable fire alarm control panel to change without notice. with an emergency voice system. For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford, CT 06472 Doc 350125 I Rev E 111/17 D SILENT 800-328-0103 ©2017 Honeywell International Inc. KNIGHT - 41114911 Honeywell SILENT' KNIGHT SK- MONITOR Intelligent Monitor Module The SK-MONITOR is an addressable monitor module for use with Honeywell Silent Knight Series fire alarm control panels (FACPs). The SK-MONITOR is intended for use in intelligent, two-wire systems, where individual address of each module is selected using the built-in rotary switches. - The SK-MONITOR supports Class A supervised or Class B supervised • •, wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. INSTALLATION The SK-MONITOR mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor° PN SMB500) is available from Silent Knight. SK-MONITOR F ---- ATUES 3ENEFITS • Single contact monitor • Panel controlled • UL Listed • Support for Class A status LED that ® Rotary address and Class B wiring flashes green in switches for fast normal state and is installation • Fully supervised solid red in alarm • SEMS screws for easy wiring SK- MONITOR Technical Specifications Fora complete listing of all compliance approvals and certifications, please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. Height: 4.5"H x 4" Wx 1.25"D (11.4 X 10.2 X 3cm) SK-MONITOR: Monitor Module Microsoft,Windows, and Shipping Weight: 6.3 oz (196 g) the Windows Logo are ACCESSORIES. registered trademarks ELECTRICAL SMB500: 4" Square surface mount electrical box or trademarks of Operating Voltage: 15 — 32VDC Microsoft Corporation. Current Draw(LED on): 5.0mA max COMPATIBILITY Silent Knight®,System Operating Current (LED flashing): 375µA The SK-MONITOR is compatible with the Sensor®and Honeywell® Standby Current: 400 µA max @ 24 VDC (one following Honeywell Silent Knight fire alarm are registered communication every 5 sec with 47K EOL); 550 µA control panels: trademarks of Honeywell max @ 24 VDC (one communication every 5 sec 6820:Addressable fire alarm control panel International, Inc. with EOL <1K) 6820EVS: Addressable fire alarm control panel This document is not 5.5 mA(with LED latched on) with an emergency mass notification system. intended to be used for LED Current: 5.5 mA (with LED latched on) 6808:Addressable fire alarm control panel installation purposes.We End-of-Line Resistance: 47K S2 6700:Addressable fire alarm control panel try to keep our product information up-to Initiating Device Circuit Wiring Resistance: 1,500 5700:Addressable fire alarm control panel date and accurate.We S2 max 5808: Addressable fire alarm control panel cannot cover all specific SLC Loop Resistance:40 S2 max. 5820XL:Addressable fire alarm control panel applications or anticipate all requirements.All ENVIRONMENTAL 5820XL-EVS: Addressable fire alarm control panel specifications are subject with an emergency mass notification system to change without notice. Operating Temperature: 32°F — 120°F(0°C — 49°C) For Technical Support, Humidity: 10% — 93% non-condensing call800-44G-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road HOfle3' VeH Northford, CT 06472 Doc 350131 I Rev G 111/17 SILENT 800-328-0103 ©2017 Honeywell International Inc. D KNIGHT '44191 Honeywell SILENT' KNIGHT SK-ISO Intelligent Fault Isolator Module The SK-ISO is an addressable line isolator module for use with the Honeywell Silent Knight Series fire alarm control panels (FACPs). - rafe :mo mu a,U CM The SK-ISO acts as an automatic switch that opens when the line voltage no�.,,,», n n.. on the signaling line circuit (SLC) loop drops below four volts. Isolator acto)n I; modules should be spaced between groups of sensors or modules in a loop "'°"`°"""`"'" `° "�` " auatoTA to protect the rest of the loop. If a short occurs between any two isolators, then both isolators immediately switch to an open circuit state and isolate the devices between them. The remaining units on the SLC loop continue to fully operate. No more than 25 devices are recommended for each group. SK-ISO INSTALLATION The SK-ISO mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor'' PN SMB500) is available from Silent Knight. FEATURES & B = N FFIT • Panel. controlled • Protects the modules • SEMS screws for easy status LED that on the SLC loop so wiringUL Listed flashes green in other devices continue • CSFM Listed normal state and is to operate solid red in alarm • FM Approved • Standard 4 inch 9 Isolates short circuits electrical box on an SLC loop mounting SK-ISO Technical Specifications Fora complete listing of all compliance approvals and certifications, please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. Dimensions: 4.5" H x 4" W x 0.25" D (11.4 x 10.2 x SK-ISO: Line isolation module 6cm) Microsoft,Windows,and are Shipping Weight: 6.3 oz (196 g) ACCESSORIES rtegeistered Windows Logomtrademarks pP� g 9 registered trademarks SMB500: 4" Square Surface Mount Electrical Box or trademarks of ELECTRICAL Microsoft Corporation. Operating Voltage: 15 — 32 VDC COMPATIBILITY Silent Knight3,System Standby Current: 450 µA max(not isolating; relay The SK-ISO is compatible with the following Sensor® and Honeywell® closed) Honeywell Silent Knight fire alarm control panels: are registered Isolation Current: 5mA max 6820: Addressable fire alarm control panel trademarks of Honeywell Fault Detection Delay: 250ms min. 6820EVS:Addressable fire alarm control panel International, Inc. Fault Detection Threshold: 4V with an emergency voice system. This document is not Line Restoration Threshold: 7V 6808: Addressable fire alarm control panel intended to be used for 6700: Addressable fire alarm control panel installation purposes.We try to keep our product ENVIRONMENTAL 5700: Addressable fire alarm control panel information up-to Operating Temperature: 32°F— 120°F(0°C — 5808: Addressable fire alarm control panel date and accurate.We 49°C) 5820XL: Addressable fire alarm control panel cannot cover all specific Humidity: 10% — 93% non-condensing 5820XL-EVS: Addressable fire alarm control panel applications or anticipate enc voices stem all requirements.All with an emergency y y specifications are subject to change without notice. For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road HOnE3'Ii(eH Northford, CT 06472 Doc 350134 I Rev F 111/17 SILENT 800-328-0103 ©2017 Honeywell International Inc. D KNIGHT Honeywell SILENT KNIGHT SK— PULL—SA I SK— PULL— DA Intelligent Pull Stations The SK-PULL-SA is a single action pull station requiring only one motion to TF I R E activate the station. The SK-PULL-DA is a dual action pull station requiring two motions to active the station. The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel (FACP). PULL ,IF i , lirDOWN Extremely easy to operate, the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal. The FACP recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. Honeywell = Z %SILENT INSTALLATION a The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-I/0 SK-PULL-SA surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm) or double gang or 4" (10.61 cm) square i electrical box. You can also use the optional (System Sensor'' PN BG-TR) FIRE trim ring if the station is being semi-flush mounted. 4PUSH PULL DOWN Honeywell = , '. SILEl T it KNLGHT 0 SK-PULL-DA FEATURES & BENEFITS • Installer can open • Key operated test and • Meets the Americans • Reliable analog • Handle latches in station without reset lock using lock with Disabilities Act communications for down position and the causing an alarm plate actuator Accessibility trouble-free operation word Activated condition ® Key matches Guidelines (ADAAG) ® Braille text on station appears, clearly • Dual-color LED is compatible FACP controls and operating handle indicating the station visible through handle locks mechanisms has been pulled guidelines (Section • Rotary address of station blinks green • UL Listed, including ® Meets ADA 4.1.3[13]) switches for fast to indicate normal UL 38, Standard of requirement for 5 lbs installation operation and remains maximum pull force to • Shell, door, and handle Manually Actuated steady red in an alarm active molded from durable Signaling System condition LEXAN' • CSFM Listed • MEA Listed SK- PULL-SA / SK-PULL-DA Technical Specifications Fora complete listing of all compliance approvals and certifications, please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. Dimensions: 5.5" H x 4" W x 1.45" D (14 x 10.2 x SK-Pull-SA: Single Action Pull Station 3.7cm) SK-Pull-DA: Dual Action Pull Station Microsoft,Windows, andthe Windows Logo are Housing Material: LEXAN polycarbonate resin registered trademarks Bi-Colored LED: ACCESSORIES or trademarks of Blinking Green: Normal BG-TR: Optional trim ring. Microsoft Corporation. Steady Red:Alarm SB-I/O: Surface backbox, indoor/outdoor. Silent Knight®,System Switch: Single pole, single throw(SPST) normally * Unless otherwise noted, specifications apply to Sensor® and Honeywell® open (N/0) switch which closes upon activation of SK-Pull-SA and SK-Pull-DA are registered the pull station trademarks of Honeywell COMPATIBILITY International, Inc. ELECTRICAL The SK-PULL-SA AND SK-PULL-DA are This document is not Operating Voltage: 15 — 32VDC compatible with the following Honeywell Silent intended to be used for SLC Standby and Alarm Current: 350µA Knight fire alarm control panels: installation purposes.We try to keep our product Wire Gauge: Up to 12AWG (3.1 mm2) 6820: Addressable fire alarm control panel information up to 6820EVS: Addressable fire alarm control panel date and accurate.We ENVIRONMENTAL with an emergency voice system. cannot cover all specific Operating Temperature: 32°F— 120°F(0°C — 6808:Addressable fire alarm control panel applications or anticipate 49°C) 6700: Addressable fire alarm control panel all requirements.All specifications are subject Humidity: 10% — 93% non-condensing 5700:Addressable fire alarm control panel to change without notice. 5808: Addressable fire alarm control panel For Technical Support, 5820XL:Addressable fire alarm control panel call 800-446-6444. 5820XL-EVS:Addressable fire alarm control panel with an emergency voice system For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northforcl, CT 06472 Doc 350135 I Rev E 111717 SILENTr 800-328-0103 ©2017 Honeywell International Inc. NA KNIGHT - 11191 Honeywell co SILENT' KNIGHT 5860 Remote Annunciator The 5860 remote annunciator, can be used to operate and program Honeywell Silent Knight fire alarm control panels (FACPs) from anywhere -.,,a...U.. within the system. =.,.� The 5860 features include an 80-character backlit LCD providing easy-to m �' w 0 - understand system messages. The annunciator is ergonomically designedTY """�"' ' . with over-sized buttons for the most frequently used features, like Reset and Silence. -7 yr ir mom In addition to status messages displayed on the LCD, there are five LEDs for alarm, supervisory, trouble, silence, and AC power status. The 5860 annunciator is available in gray to match virtually any decor and 5860/5860R red for applications where the annunciator must stand out. The annunciator enclosure can be surface or flush mounted. A trim ring kit is available for surface mounting. COMPATIBILITY The 5860 is compatible with the following Honeywell Silent Knight FACPs: 6820: Addressable fire alarm control panel with up to 1,110 addressable points 6820EVS: Addressable fire alarm control panel with an emergency communication systems and up to 1,110 addressable points 6808: Addressable fire alarm control panel with up to 198 addressable points 6700:Addressable fire alarm control panel with up to 100 addressable points 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency communication systems 5808:Addressable fire alarm control panel 5700:Addressable fire alarm control panel FEATURES & BENEFITS • 80-character backlit • Support for • Five Status LEDs • Accommodates wiring • Accepts user codes or LCD display (4 lines simultaneous use of ® Available in red or light lengths up to 6000 ft, fire fighter's key with 20 characters per multiple 5860s gray color from the control panel Larger• keypad buttons line) for added design and • Easily view current makes it easier to • Tactile / audible status by alarms, install flexibility maneuver for system feedback when a key is supervisories, or reset and silencing pressed on the troubles annunciator • Uses the RS-485 SBUS to interface with the panel 5860 Technical Specifications Fora complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft,Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. • Wire Runs Up to 6000 Feet From FACP Silent Knight® and Honeywell®are registered •"'‘ trademarks of Honeywell International, Inc. it tag 4fW4 @ �W�R0. �r4+SBUS 44Q Lin o i of a lipvr This document is not ` -- intended to be used for 5860 5860 5860 installation purposes. We try to keep our product • Up to Eight 5860s Per 5700 or 6700 System information up-to • Up to 12 5860s Per 5808, 6808, 5820XL, or 5820XL-EVS System date and accurate.We • Up to 16 5860s per 6820 or 6820EVS System cannot cover all specific Compatible Silent Knight FACP applications or anticipate all requirements.All specifications are subject to change without notice. For Technical Support, 5860 Features call 800-446-6444. PHYSICAL ORDERING INFORMATION Dimensions: 9.1"W x 7.4"H x 1.5"D (23.1W x 18.8H x 5860: Remote Annunciator, four line (4x20) LCD 3.8D cm) annunciator with 20 characters per line. Gray Shipping Weight: 2.8 lbs (1.3 kg) 5860R: Remote Annunciator, four line (4x20) LCD Color: 5860R: Red; 5860: Gray annunciator with 20 characters per line. Red ENVIRONMENTAL ACCESSORIES Operating Temperature: 32°F to 120°F (0°C to 5860TR: Red Trim Ring for surface mounting 49°C) 5860TG: Gray Trim Ring for surface mounting Humidity: 10% - 93% non-condensing) AGENCY LISTINGS AND APPROVALS ELECTRICAL UL listed Operating Voltage: 24VDC CSFM approved Standby Current: 20rnA Meets NFPA 72 requirements Alarm Current: 25mA FM approved MEA approved For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford, CT 06472 Doc 3502241 RevJ 112/17 SILENT' 800-328-0103 ©2017 Honeywell International Inc. ® KNIGHT 111411 Honeywell SILENT' KNIGHT 5496 Intelligent Power Module The 5496 intelligent power module is the most cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO, and Wheelock®. The 5496's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. The 5496 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with the Honeywell Silent Knight series fire alarm control panels (FACPs). The 5496 is the cost-effective solution for powering notification appliances required bythe Americans with Disabilities Act Honeywell pp q (ADA). The 5496 has built-in ANSI cadence pattern. The output circuits can be programmed as notification appliance circuits, or as auxiliary power (configurable for constant, resettable, or door holder power). Hnneyw • Compatibility 5496 The 5496 is compatible with the following Honeywell Silent Knight FACPs: • 6820 / 6820EVS • 5820XL/ 5820XL-EVS • 6808 • 6700 • 5808 • 5700 FEATURES (St BFN EFITS • UL Listed or 6 amps • Built-in - • NACs are • Communicates to the • Lightweight design of notification power synchronization for programmable as FACP via 4-wire SBUS adds to ease of • Power supply's appliances from notification appliance (wire runs up to 6000 installation and advanced switch mode Gentex, AMSECO, circuits, or as auxiliary ft) reduces shipping System Sensor, and power to be used as costs design reduces • AC loss delay option damaging heat and Wheelock constant, resettable, shuts off power to • ANSI Cadence pattern manages power up to • Four power-limited or door holder power non-essential high output capability 50% more efficiently notification outputs; 2 • 3 amps per output current accessories built-in than other systems Class A or 4 Class B, or circuit like magnetic door • UL 864,1481 & 1971 • 24 VDC filtered output 1 Class A and 2 Class • Ground fault detector holders listed voltage •• CSFM approved MEA approved • OSHPD CCA) OSP-0065-10 (see accessories) 5496 Technical. Specifications For a complete listing of all compliance approvals and 4 Outputs Programmable certifications, please visit p g www.silentknight.com. as Notification Appliance Circuits, or as Auxiliary Power Microsoft,Windows, and the Windows Logo are registered trademarks or trademarks of Output 1 SBUS Communication Microsoft Corporation. To a Compatible Silent Knight FACP System Sensor° and Output 2 -441Honeywell®are registered trademarks of Honeywell International, Inc Output 3 , This document is not intended to be used for Output 4 All installation purposes.We try to keep our product HIMH1Nl'Y I information up-to Auxiliary Power Can Be date and accurate.We Programmed To Be Constant, apppplicaatio cannotapplications or anticipate ate Resettable, or Door Holder Power all requirements.All specifications are subject to change without notice. For Technical Support, PHYSICAL required on each Class B circuit call800-446-6444 Overall Dimensions: 16" H x 12.25"W x 3" D (40.6 x Battery Charging Capacity: 7.0 — 35.0AH 30.9 x 7.6 cm) Shipping Weight: 8.71bs ORDERING INFORMATION 5496: Intelligent Power Module ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to ACCESSORIES 49°C) RBB: Remote Battery Box Accessory Cabinet. 16" Humidity: 10 to 93% relative humidity (non- Wx 10" H x 6" D (406 mm W x 254 mm H x 152 mm condensing) D) SK-SCK: Seismic Compliance Kit ELECTRICAL: AC Input: 120VAC at 2.7A AGENCY LISTINGS AND APPROVALS Output: 24VDC at 6A • CSFM approved Standby&Alarm Current: 10mA Notification/Aux. Power Circuits: 4 • N FPA 72 Output Configuration: • UL listed 2 Class A (Style Z) 4 Class B (Style V) • FM approved 1 Class A& 2 Class B Amps Per Output Circuit: 3.0 (6.0 amps total) • City of NY: 429-90-E Vol XIV Notification Circuit Output: 20.4— 27.3VDC @ 3.0A each End-of-Line Resistance:4.7k W EOL resistor For more information Learn more about Silent Knight's Product and other products available by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road HoneyveH Northford, CT 06472 800-328-0103 Doc 3503371 Rev FI 11/17 SILENT" www.silentknight.com ©2017 Honeywell International Inc. ®KNIGHT P POTTER RTs _o/RTs_c The Symbol of Protection Room Temperature Switch Features • Easily installed • Completely sealed sensor, moisture and vapor resistant • Highly resistant to vibration and corrosion • Highly sensitive to temperature changes • No sensitivity loss due to aging (41) • Repetitive operation without the need to replace sensing elements • Small compact design • Precision and quality at low cost SIGNALING c UL US LISTED Important: This document contains important information on the installation and operation of room temperature switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. Description Technical Specifications Each unit consists of a bi-metal operating mechanism, featuring Enclosure White ABS hermetically sealed precious metal contacts, N.O. or N.C., which automatically reset for repetitive operation, eliminating the need for Dimensions 2 1/16"W x 3 7/16"L x 1 1/4"H sensing element replacement. (5,2cm W x 8,7cm L x 3,2cm H) Small compact design, highly resistant to vibration and corrosion. Epoxy sealed stainless steel case, bi-metallic P �� g Y Sensor Easily installed using the enclosed hardware or adhesive mounting operating mechanism. pad. Contacts Silver clad, available normally open or normally Screw terminals permit easy installation in single or multiple closed detector circuits. Electrical 1 Amp at 24VDC Rating Application Temperature 40° ±5°F (4,5° ±3°C) Setting The RTS Series complies with the requirements of NFPA 13 and 72 for a room temperature switch to operate at 40°F to protect a dry pipe Terminals Screw Terminals valve from freezing. The RTS can also be used for other temperature Mounting Wall Mount, Surface detection applications. Operation The normally open detector, RTS-O, will close the contact when the temperature drops below 40°F (4,5°C). The normally closed detector, RTS-C, will open the contact when the temperature drops below 40°F (4,5°C). The detector will automatically reset to the normal state when the temperature rises above 40°F (4,5°C). The RTS Series Room Temperature Sensors are precision engineered, designed and manufactured for commercial or residential use. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-0988 / Canada 888-882-1833 • www.pottersignal.com 5401019-REV H • 09/15 PAGE I OF 2 P POTTER RTS -O/RTS -C The Symbol of Protection Room Temperature Switch Inspection, Testing, & Maintenance The frequency of inspection and testing of the RTS and its associated monitoring system shall be in accordance with applicable local and NFPA codes and standards. Manufacturer recommends quarterly or more frequently. Functional test can be accomplished by spraying the RTS with circuit cooler or equivalent. More accurate test requires exposing the RTS to 40°F ± 5°F. The RTS requires no maintenance other than ensuring the vent holes are not obstructed. Fig I RTS-0 RTS-0 0 Control Unit Supervisory Device EOLR Circuit O RTS-C RTS-C 0 O O O O Control Unit Supervisory Device EOLR Circuit 0 DWG# 1019-1 NOTE: This RTS does not have duplicate terminals. Do not use looped wire under terminals. Break wire run to provide supervision of connections. RTS Mounting Template Ordering Information Fig 2 Model Description Stock No. i RTS-0 Normally Open Room Temperature 1010108 ® O Switch ID RTS-C Normally Closed Room Temperature 1010109 I O O - O 0 i Switch o O NOTICE Supervisory switches have a normal service life of 10-15 years. i 0 0 - O 0 J However, the service life may be significantly reduced by local environmental conditions. CI 0 0 l Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-0988 / Canada 888-882-1833 • www.pottersignal.com 5401019-REV H • 09/15 PAGE 2 OF 2 AcROX DBX As Built Drawings Cabinets f BY SPACE AGE ELECTRONICS Offer fire departments and other authorized personnel the convenience of having AS BUILT building layouts and alarm documents DRAWINGS readily accessible with one of these durable cabinets available in a variety of sizes. AS BUILT AS BUILT DRAWINGS DRAWINGS SPECIFICATIONS The DBX As Built Drawings Cabinet shall be constructed of 16 gauge cold rolled steel and finished with a durable red powder coat. The front cover will include a durable label displaying "AS BUILT DRAWINGS" in 1" white indelible lettering, applied to the FEATURES cover relative to the orientation of the installed back box. The front cover will feature a high security CAT 30 keyed door lock. Mp0.1101sa • 16 gauge steel construction Back box shall have universal surface mount design and wall mounting holes. SINCE • Durable red powder coat • White 1" indelible lettering "AS BUILT DRAWINGS" ORDERING INFORMATION on included label P/N# Size Width Height Depth • Stainless steel piano hinge with CAT 30 keyed SSU00674 AA 12 1/4" 14 1/4" 4" door lock SSU00677 A 26 1/4" 14 1/4" 4" • Surface mount box SSU00678 D 26 1/4" 23 5/8" 4" • Wall mounting holes for vertical or horizontal ACCESSORIES orientation • Semi flush flange available P/N#SS000680 for both A and D sizes A Size Semi-Flush Flange Kit P/N#SS000681 D Size Semi-Flush Flange Kit www.isae.com I toll free 1.800.486.1723 I fax 508.485.4740 n =ma �,s � �� ©Copyright 2018 Space Age Electronics,Inc.I This document subject to change without notice I LT10045 I Rev.G NFPA ADA (çBatteryCenter , Your Replacement Battery Source Rechargeable Sealed Lead Acid Battery (12V 12Ah/20hr) 151±1 98±1 I These rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is +, ,a absorbed by separators and thus *BatteryCenter* immobilized. Should the battery I be accidentally overcharged BC-1�212r0 r producing hydrogen and oxygen, Sealed Rechargeable Bailer*/ cAa,� special one-way valves allow the . .. �-, m I G.35 I �H gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is ® Q completely sealed and is, therefore, maintenance-free, leak TerminalF2 proof and usable in any position. Unit:mm Battery Construction Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid SPECIFICATION Performance Characteristics .. 20 hour rate (0.6A, 10.5V) 12Ah Nominal voltage 12V 10 hour rate (1.14A, 10.5V) 11.4Ah Number of cells 6 Capacity 77°F(25°C) 5 hour rate (2.05A, 10.5V) 10.2Ah Length (mm/inch) 151/5.94 1 hour rate (7.5A, 9.6V) 7.5Ah Width (mm/inch 98/3.86 Internal Resistance Full charged Battery77°F(25°C):20mQ Height(mm/inch) 95/3.74 104°F(40°C) 102% Total Height (mm/inch) 101/3.98 Capacity affected by 77°F(25°C) 100% Temperature Approx.Weight (kg/lb) 3.4/7.48 (20 hour rate) 32°F(10°C) 85% 5°F(-15°C) 65% Capacity after 3 month storage 90% Self-Discharge Capacity after 6 month storage 80% 68°F(20°C) General Features Capacity after 12month storage 60% • Absorbent Glass Mat(AGM) Max. discharge current 77°F(25°C): 180 A(5S) technology for efficient gas Float: 13.6-13.8 V/77°F/(25°C) recombination of up to 99% and Charge Cycle: 14,5-14,9 V/77°F/(25°C) freedom from electrolyte (Constant Voltage) Max. Current: 3.0A maintenance or water adding. ® Not restricted for air transport- Discharge Constant Current (Amperes at 77°F 25°C) complies with IATA/ICAO Special EVolndtsP/Cell oints 5 min 10 min 15 min 30 min lh 3h 5h 70h 20h Provision A67. 1.60V 45.6 31.0 24.3 13.3 7.50 3.15 2.12 1.18 0.61 o UL-recognized component. 1.65V 44.2 30.1 23.8 12.9 7.43 3.12 2.10 1.17 0.61 o Can be mounted in any orientation. 1.70V 42.7 29.2 23.2 12.6 7.37 3.09 2.07 1.16 0.61 ® Computer designed lead, calcium tin 1.75V 41.3 28.3 22.7 12.3 7.30 3.06 2.05 1.14 0.60 alloy grid for high power density. 1.80V 39.8 27.5 22.1 12.0 7.23 3.03 2.02 1.12 0.59 o Long service life, float or cyclic applications. Discharge Constant Power (Watts at 77°F 25°C) o Maintenance-free operation. V End°I Points ts/Cell 5 min 10 min 15 min 30 min 45 min lh 2h 3h 5h Low self discharge. 1.60V 88.0 59.2 47.7 28.2 21.0 15.6 9.78 6.52 4.24 • 1.65V 82.5 55.7 45.1 26.8 20.0 14.9 9.49 6.36 4.17 1.70V 77.1 52.3 42.5 25.3 19.0 14.2 9.17 6.19 4.09 1.75V 71.7 48.8 39.8 23.9 18.0 13.5 8.81 6.00 4.00 1.80V 66.4 45,4 37.2 22.4 17.0 12.8 8.43 5.80 3.90 Your Replacement Battery Source Charge characteristic curve Discharge characteristic (25°C) ki; ai Constant voltage charging characteristic 13.0 .Co> ' (13 (0.25CA, 25°C) (%)- (rCA)- (V)- 12.0 120- 0.25- 15.0- Charged volume w 11.0 100 0.20- 05A 11.4A 0.6A 14.0- 0 10.0 .09A 80 Charge voltage >- 0.15- 36A 24A 12A 7.5A 60- 13.0- w 9.0 ' - 0.10- I-- 40- 12.0 m 8.0 20- 0.05- 11.0- Charging current 0 0- 0- 0 0 1 2 3 5 mi 10 20 30 60 2 3 h5 10 20 30 0 2 4 6 8 10 12 14 16 18 20 CHARGING TIME (HOURS) DISCHARGE TIME Temperature effects on float life Cycle service life in relation to depth of discharge 10 120 - 100 -wiiiivi‘k iri 0 :: \ ix w 2.30 V/cell >- LL1 a 100%D.O.D. 50%D.O.D. 30%D.O.D. V 40 20 0.1 0 200 400 600 800 1000 1200 1400 10 20 30 40 50 60 70 TEMPERATURE CC) NUMBER OF CYCLES (CYCLES) Relationship between charging voltage Self-discharge characteristic and temperature N > > > _ 1 110 - > - > - > -> - v v v v 100 w 0 15.6 - 10.4 - 7,8 - 5,2 -2.6 - 90 - 0 15.0 - 10.0 - 7.5 - 5.0 - 2.5 CyC`FSF } 80 . _ 0 1- 3- 14.4 - 9.6 - 7.2 - 4.8 -2.4 (.7 70 _ • a Q U13.8 _ 9.2 _ 6.9 _ 4.6 _ 2.3 STAND e�US V 60 = 40`C 30'C 20°C E 50 13.2 _ 8.8 _6.6 4.4 2,2 - 40 -1 I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 I - - -10 0 10 20 30 40 50 60 O 2 4 6 8 10 12 14 16 18 20 AMBIENT TEMPERATURE (°C) STORAGE TIME: MONTHS Life characteristics of standby use Temperature effects on capacity 120 120 100 100 0 p5C F' 80 0 80 01C >-~ >- 0.2C U 60 V 60 a Testing conditions floating voltage: 2.27 to 2.30 V/ II a 0C 0 40 ambient temperatu'e: 25°C(77°C ) 0 40 2.00 20 20 - 3'0C 0 0 0 1 2 3 -20 -10 0 10 20 30 40 50 LIFE (YEAR) TEMPERATURE CC) HWF2 COM SERIES LTE / I P Single or Dual Path Commercial Fire Communicators The HWF2-COM Series LTE / IP fire communicators are single or dual path commercial fire alarm communicators that offer Contact ID reporting with any FACP (fire HWF2A-COM alarm control panel) with a built-in dialer. IMC244061 Carensecil Fire CarsvAcalor . ,. Moron Models include: Noseyagas HWF2A-COM (AT&T LTE& I P) HWF2V-COM (Verizon LTE & IP) Both models connect directly to the primary or secondary communication ports of a fire panel's digital alarm communicator transmitter(DACT). Three selectable reporting paths include: LTE cellular only, IP only, or IP primary with LTE cellular backup. All signals from the HWF2-COM Series are delivered to the AlarmNet® network control center which routes highly encrypted, cybersecured Ethernet data packets via a customer-provided Internet connection or LTE cellular network to the appropriate central station. The AlarmNet® network control center is fully redundant and monitored 24/7. Installation and programming are easy using the handheld 7720P Programming toot HWF2V-COM iffifw-cou camulcski Mmannouks ■I ..a. Kau K�. liontneeli FEATURES AND BENEFITS • LTE and IP connection tested every day connection (LAN or WAN), DSL model or • Diagnostic LEDs indicate signal strength • Three selectable reporting paths: LTE cable modem and status cellular only, IP only, or IP Primary with LTE • Data transmits over standard Contact ID • Choice of LTE provider services cellular backup protocol but is secured with the industry's • QOS: Quality of Service diagnostics via • Requires no change to the existing FACP advanced encryption standard (AES 256 AlarmNet conveys vital communicator configuration bit) information including signal strength, • Connects directly to the primary and • Supports both dynamic (DHCP) or public message path used, and when the message secondary telephone ports of a DACT and private Static IP addressing was received • Plan choices range from 5 minute, 60 • Reliable connection: IP and cellular • 7720P Handheld programmer for easy minute, 6 hour, and 24 hour supervision connection tested every day setup intervals • Built-in, standalone power supply module. • Operates overthe following communication Onboard charging circuit design protocols: LTE, HSPA+(4G) HSPA (3G) accommodates battery backup. Includes • Works over any type of customer provided primary power and battery supervision Ethernet 10/100 based network Honeywell The HWF2-COM LTE/ IP fire communicators operate over the most • Primary Subscriber ID (four digits), obtained from your monitoring modern and common cellular networks including LTE, 4G and3G. station • Communication Module MAC ID, and MAC CRC number located on They connect to any customer provided Ethernet 10/100 base the outside of the box and inside of the module network connection (LAN or WAN), DSL or cable modem. Selectable All parameters are assigned by the monitoring station. reporting path feature allows the radios to be configured for a single or dual path, while providing appropriate supervision intervals ALARMNET based on NFPA 72 requirements. Selectable paths and supervision AlarmNet communications technology provides a highly reliable timing intervals include: alternative for the transmission of alarm signals. The network SELECTABLE DESCRIPTION SUPERVISION provides extensive coverage in the United States and Canada. The PATH TIMES Alarm Net Network Control Center processes signals from powerful servers in multiple locations equipped with 24/7 infrastructure 2010 Cell Single path, cellular 5 Minutes support. Redundant hardware servers, real-time backup databases, 2010 IP Single path, IP 5 Minutes and generators with battery backup at all locations ensure 2010 IP & Cell Dual path, IP and cellular 24 Hours continuity of service. Signals from AlarmNet are transmitted to 2013 Cell Single path, cellular 60 Minutes central station receivers using multiple communication paths consisting of the Internet, LTE radio network, or toll free plain old 2013 IP Single path, IP 60 Minutes telephone service (POTS). Visit AlarmNet.com to learn more. 2013 IP& Cell Dual path, IP and cellular 6 Hours INSTALLATION REQUIREMENTS, UL COMPLIANCE OPERATION To meet UL864/NFPA requirements, ensure the following: When an event occurs, the FACP goes off-hook to dial the central station. The HWF2-COM Series dialer capture module detects the • HWF2-COM Series must be installed in accordance with the National off-hook condition and provides the fire panelwith a dial tone.When Fire Protection Association (NFPA) standards 70 and 72 the fire panel detects the dial tone, it begins dialing the central • HWF2-COM Series must be mounted in the same room and within station. 20 feet of the fire panel. • HWF2-COM Series and all equipment used for the IP connection After the dialing is completed, the dialer capture module returns a (e.g., router, hub, modem, etc) must be UL-listed, powered from an signal to the fire panel. The fire panel then sends the Contact ID unswitched branch circuit, and be provided with appropriate standby. reports to the dialer capture module, which in turn sends a signal power. after the report is successfully received from the fire panel. The • HWF2-COM Series must use the 7AH battery(not included) to dialer capture nodule sends the Contact ID reports to the HWF2- provide 24 hour backup capability COM Series communications module.When all the reports are sent, the fire panel goes on-hook. The HWF2-COM Series communications module then transmits the messages to the central station either over the LTE network or the Internet (depending on configuration). FIRE COMMUNICATOR / PANEL CAPABILITY The HWF2-COM Series is compatible with fire alarm control panels that use the Contact ID communications format as described in the SIA DC-05 standard. EASY TO PROGRAM The HWF2-COM communicator can be pre-programmed using the 7720P programmer to enter all central station information. This is saved to the HWF2-COM communicator panel memory. When the HWF2-COM is installed at the site and connected to the Internet/ Intranet, it registers with the AlarmNet Receiver. For most installations, the only required parameters are: • Primary City ID (two digits), obtained from your monitoring station • Primary Central Station ID (two digits), obtained from your monitoring station Page 2 of 3 — DH-62010:B • 6/27/2019 HWF2-COM SERIES TECHNICAL SPECIFICATIONS ELECTRICAL Both models include: Transformer: • Red cabinet with key and lock AlarmNet'' is a registered • Primary: 120VAC, 60Hz, 0.5A • Wall outlet box trademarks of Honeywell • Secondary: 18VDC, 50VA • Dialer capture module International Inc. Battery: • LTE communications module ©2019 by Honeywell International • One 12 V 7.0 AH lead-acid battery: (not • Antenna and mounting adapter Inc. All rights reserved. supplied) • PowerBoostl power supply Unauthorized use of this document • Battery charging current: 1 Amp maximum • LED display board is strictly prohibited. • Battery discharge current: Standby 230mA, • Transformer Active 950mA • Manual and required screws This document is not intended to be • Cables, etc. used for installation purposes. We CABINET SPECIFICATIONS try to keep our product information ANTENNA AND EXTERNAL up-to-date and accurate.We cannot • Dimensions: 14.875" H x 12.75" W x 3.0" D HARDWARE (37.8cm H x 32.4cm W x 7.6cm D) cover all specific applications or • Color: Red CELL-ANT3DB: 3dBA gain antenna anticipate all requirements. All WA7626-CA: SMA to N adapter cable specifications are subjectto change SHIPPING DIMENSIONS 7626-50HC: 50 ft. antenna cable, low loss without notice. • Weight: 5.3 lbs (6.94kg) • Dimensions: 15.625" H x 13.79" W x 9.25" D Note: The WA7626-CA adapter cable and Country of origin: USA (39.7cm H x 34.9cm W x 23.9cm D) 7626-50HC antenna cable are only required when installing the CELL-ANT3DB TEMPERATURE AND HUMIDITY antenna remotely. RANGES OTHER ACCESSORIES This system meets NFPA requirements for operation at 0 - 49°C/32-120°F and at a 7720P: HWF2V-COM, HWF2A-COM and relative humidity 93%+- 2% RH (non- IPGSM-4G handheld programmer condensing at 32°C +- 2°C(90°F +-3°F). HPTCOVER: Plug-in transformer box for However the useful life of the system's HWF2V-COM, HWF2A-COM, and IPGSM- standby batteries and the electronic 4G communicators components may be adversely affected by BAT-1270: Battery 12 Volts, 7AH, sealed extreme temperature ranges and humidity. AGENCY LISTINGS AND Therefore, it is recommended that this APPROVALS system and its peripherals be installed in an environment with a normal room The listings and approvals below apply to temperature of 15 - 27°C/60-80°F. the HWF2-COM Series communicators. In some cases, certain modules may not be PRODUCT LINE INFORMATION listed by certain approval agencies,or listing HWF2V-COM: LTE Digital Cellular Fire may be in process. Consult the factory for Alarm Communicator and Internet Panel, latest listings. Verizon LTE/ IP UL Listed: S789 HWF2A-COM: LTE Digital Cellular Fire CSFM: 7300-1645:0511 Alarm Communicator and Internet Panel, FDNY: Approved AT&T LTE / I P THE FUTURE IS Honeywell Power Products WHAT 12 Clintonville Road WE MAKE IT Northford, CT 06472-1610 203.484.7161 DH-62010 I B 106/19 www.honeywellpower.com �2019 Honeywell International Inc. Honeywell Th SYSTEM 4SENSOR® Selectable-Output - Low Frequency Sounder and Low - �� F - -, t Frequency Sounder 111 . ' f R Strobes for Wall E E F Applications R SPECTFIert SpectrAlert° Advance audible visible notification products ,4 o v A IIV c E are rich with features guaranteed to cut installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of low frequency sounder and low frequency • 520 Hz ± 10% square wave tone sounder strobes in the industry. With white and red plastic housings, • Plug-in design with minimal intrusion into the back box dual listed for wall and ceiling mounting, SpectrAlert Advance can • Tamper-resistant construction meet virtually any application requirement. • Field-selectable candela settings on wall units: The wall-mount low frequency sounder, and low frequency sounder 135, 150, 177, and 185 strobes were designed to address the NFPA 72 sleeping space • Rotary switch for low frequency sounder tone requirements that require a low frequency notification appliance that • Universal mounting plate for wall units operates within frequency range of 520 Hz ± 10% and is of a square wave tone. Like the entire SpectrAlert Advance product line they • Mounting plate shorting spring checks wiring continuity before include a variety of features that increase their application versatility device installation while simplifying installation. All devices feature plug-in designs • Electrically compatible with legacy SpectrAlert devices with minimal intrusion into the back box, making installations fast • Compatible with MDL3 sync module and foolproof while virtually eliminating costly and time-consuming • Listed for ceiling or wall mounting ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, Agency Listings automatic selection of 12- or 24-volt operation, and a rotary switch for 520 Hz low frequency sounder tones. SIGNALING MEA .. LISTED APPROVED approved i`- S4011 (sounder) 3047563 MEA452-05-E 7135-1653:0223 S5512(strobes) 7125-1653:0224 SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•CircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings including 135, 150, 177, and 185. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone and have a permanent marking on the housing that reads "low frequency sounder". Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for fire protective service. The low frequency sounder and the Sync•CircuitTM MDL3 Module accessory, if used, shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts (includes fire alarm panels with built in sync). When used with the Sync•Circuit Module MDL3, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three pattern, non-temporal (continuous) pattern and coded supply within the frequency range of 520Hz ± 10% square wave tone. The low frequency sounder shall operate on a coded or non-coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes, the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 4"/is x 4"/le x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Frequency Range 520 Hz ± 10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 DC/FWR or regulated 24 DC/FWR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (162 mm L x 119 mm W x 64 mm D) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inches D (142mmLx 119mmWx33mmD) Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D Dimensions (SBBR, SBBW) (162 mm L x 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D (SBBR, SBBW) (145 mm L x 120 mm W x 76 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. UL Current Draw Data UL Max.Low Frequency Sounder Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal 3 High 191 262 138 166 Continuous High 292 384 138 208 Coded High 292 388 153 205 UL Max.Current Draw(mA RMS),2-Wire Low Frequency Sounder Strobe,High Candela Range 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal 3 277 292 325 344 Temporal 3 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 Low Frequency Sounder Tones and Sound Output Data Low Frequency Sounder and Low Frequency Sounder Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Volts Volts Reverberant Anechoic Switch Position Sound Pattern DC FWR DC FWR DC FWR DC FWR 1 Temporal 3 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 3t Coded 80 80 80 80 80 80 90 90 t Sounder ratings provided are for continuous voltage as provided by the NAC SpectrAlert Advance Dimensions 4.7 in. 2.5 in. ► r 4.7 in. -1.3 in1.1 ♦ �� I . � � it ��-�� no nnr r�uvr � =y ill 1 in ll - it =El /I \\ii \\ // i\ i!!' 1 lir' ��^ rflt t'1, PiIFif If 6.4 in. it 5.6 in. 11; t� r, \, ,, p n _ i / � %k c/ 11111 ,I Q LOW MOUE=SOUNDER , ...I A-.,-,-,,..... IP Wall-mount low frequency sounder strobes Wall-mount low frequency sounder • SpectrAlert Advance Ordering Information Model Description Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe, High cd, Red P2WH-LF 2-Wire Low Frequency Sounder Strobe, High cd, White Low Frequency Sounders HR-LF Low Frequency Sounder, Red HW-LF Low Frequency Sounder, White Accessories SBBR Surface Mount Back Box, Wall, Red SBBW Surface Mount Back Box, Wall, White TR-HS Trim Ring, Wall, Red Notes: "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. *-, SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2015 SystemSensor. Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com . SENSORwww.systemsensor.com for current product information,including the latest version of this data sheet. AVDS16404. 1/15 VI SYSTEM ...,._ . . SENSOR® pr 100 •I1I•I1I1 1I1I1III1 ,, ,, ,_. F II1I1I1II F 1 1 t . � 1 Sill, 1111111i ti Indoor Selectable- - .�I I ' R _ y R Output Horns, E h E f.r Strobes, and . Horn Strobes for 1 Wall Applications ,,,,, System Sensor L-Series audible visible notification �2 II products are rich with features guaranteed to cut u ,? , A• }; • installation times and maximize profits with lower4 *F current draw and modern aesthetics. -�'V — .....) __ Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns, strobes, and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, • Tamper-resistant construction and FUEGO-printed devices, System Sensor L-Series can • Automatic selection of 12- or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns, strobes, and horn strobes 15, 30, 75, 95, 110, 135, and 185 include a variety of features that increase their application versatility • Horn rated at 88+ dBA at 16 volts while simplifying installation. All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage, the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring, so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING oL ® LISTED APPROVED I'“ t I 85512 FM approved except 7125-1653.0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 AVDS865-05•2/22/2018•Page 1 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•CircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 1.91 "D (143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"Lx4.7"Wx 1.25"D (143mmLx 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D (133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05•2/22/2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-1Z5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9" Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 *Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVOS865-05.2/22/2018•Page 3 L-Series Dimensions 1.91" = 3.46° - 3.46" --E.- 48.5 mm 88 mm 1.25" 3.57° 1.55" 88 mm = = 1.25" 32 mm (9.1 cm) (3.9 cm) 32 mm - . -r"....� l� r� ii .o� ,:.� ., i�' .Ir'�rT,::, ,ur-,a'\l. pOtiir�e ;1Qp iii iTi,', i eee ' 'ee eeeeee ni 5.27" �e�,ee1e�gea p"ppp '" 5.38" : : C 133.9 mm mil' 5.27" ,8QOQOp0p1QQ (13.7 cm) O �' !J!! 133.9mm ppppppppppp iee•iei•111111.1111 `� ' `eeeeee!II j T o Y A0548-00 A0547-00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL --zi 4.70" (11.94cm) _ — 1.91" 4.7" 1.25" 4.82" _— (4.85 cm) 119 mm 32 mm (12.24 cm) -a 1.85" 1.25" V a (4.69 cm) (3.18 mm) ii I-----i --K 0 .‘ .fee 1el l 0 iii;ii:i,ii .67° 0.1.1e 00. 5.67" 5.78" O I'.EQoa ;14.68cm) i i (14.4 cm) 144 mm e�eoaoo�e�p I ieeaeee'eeeeeeeeeee I_�, , e4heeeehiit1 , ,ihhhhh � Ail A0550-00 A0549-00 A0554-01 Strobe, Horn Strobe Horn Wall Surface Mount Back Box SBBRUSBBWL . L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns* P2RL 2-Wire, Horn Strobe, Red HRL* Horn, Red P2WL 2-Wire, Horn Strobe, White HWL* Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HGRL* Compact Horn, Red P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White HGWL* Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBRL Wall Surface Mount Back Box, Red P4RL 4-Wire, Horn Strobe, Red SBBWL Wall Surface Mount Back Box, White P4WL 4-Wire, Horn Strobe, White SBBGRL Compact Wall Surface Mount Back Box, Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box, White SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All-P models have a plain housing (no "FIRE" marking on cover). All -SP models have "FUEGO" marking on cover. All-ALERT models have "ALERT" marking on cover. *Horn-only models are listed for wall or ceiling use. *-Th_ SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2018 System Sensor. Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com ,SENSOR y stemsensor.com for current product information,including the latest version of this data sheet. www.s AVDS865-05•2/22/2018 *Th, SYSTEM __V 51LSOI?® .1 yIsIs ISI1iI1I1 F , F ' 1 ' 1 ' 1 ' I . ..' Illy - Indoor Selectable- 1 ' R e_ R Output Horns, E E Strobes, and Horn Strobes for • - _ , _11.141.1 Wall Applications . „yrs _ . I , System Sensor L-Series audible visible notification ilit, . \.s �,• #. y, ti '. products are rich with features guaranteed to cut .,� Q ir rl N I i-; ; - i installation times and maximize profits with lower current draw and modern aesthetics. *_-. - Features • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns, strobes, and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, • Tamper-resistant construction and FUEGO-printed devices, System Sensor L-Series can • Automatic selection of 12- or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns, strobes, and horn strobes 15, 30, 75, 95, 110, 135, and 185 include a variety of features that increase their application versatility • Horn rated at 88+ dBA at 16 volts while simplifying installation. All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage, the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring, so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING 7.-r UL o APPROVED I.�y vt:i LISTED S5512 FM approved except 7125-16530504 S4011 for ALERT models 7135-16530503 3057383,3057072 AVDSB65-05•2/22/2018•Page 1 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•CircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 2'/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 1.91 "D (143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D (143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D (133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05•2/22/2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe.Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1KTemporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 *Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains • constantly on. AVDSB65-05.2/22/2018•Page 3 L-Series Dimensions 1,91" _ 3.46° - 3,46" 48.5 mm 88 mm 1.25" ---3.57° 1.55" 88 mm = = 1.25° 32 mm (9.1 cm) (3.9 cm) /� 32 mm i _..;[ gyp/Ipi,,,/p1 i 10/ .. I . 1.A 5.385.27" 1_ 1_1•4■_•_•• (13.7 c m) I O133.9mm 5.27"133.9mm 0000IJIl wooly wooly 1 A0548-00 A0547-00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL 4.70" a (11.94 cm) _ — 1.91" 4.7" 1.25" 4.82" (4.85 cm) 119 mm 32 mm (12.24 cm) �� 1.85" 1,25" r a (4.69 cm) (, --e----,-..-.-„.7. -,-,.:-.-,, „. IPO K=3 — Di - .. + : d,i ,NM1r,r r 611.Lri.1.e■ 5.78 5.67 5.67' Iiiiiii0 li��;:14.68 cm) O (14.4 cm) 144 mm • .0000.81, i loll ) ililelilil _ 0 (... i.//Mil P,, ,, AI _4111 ---" E. 1--ff IF _ A0554-01 Strobe, Horn Strobe A0550-00 Horn A0549-00 Wall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns* P2RL 2-Wire, Horn Strobe, Red HRL* Horn, Red P2WL 2-Wire, Horn Strobe, White HWL* Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HGRL* Compact Horn, Red P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White HGWL* Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBRL Wall Surface Mount Back Box, Red P4RL 4-Wire, Horn Strobe, Red SBBWL Wall Surface Mount Back Box, White P4WL 4-Wire, Horn Strobe, White SBBGRL Compact Wall Surface Mount Back Box, Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box, White SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All-P models have a plain housing (no "FIRE" marking on cover). All -SP models have "FUEGO" marking on cover. All -ALERT models have "ALERT" marking on cover. *Horn-only models are listed for wall or ceiling use. Vi SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2018 System Sensor. Phone, 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com SENSOR stemsensor.com v for current product information,including the latest version of this data sheet. wVUW.s AVDS865-05•2/22/2018 INSTALLATION AND MAINTENANCE INSTRUCTIONS SILENT W 91 KNIGHT 0 by Honeywell 12 Clintonville Road, Northford, CT 06472 SK-Relay 203.484.7161; Fax: 203.484.7118 y www.silentknight.com SPECIFICATIONS Normal Operating Voltage: 15 to 32 VDC Maximum Current Draw: 6.5 mA (LED on) Average Operating Current: 2301iA direct poll; 255pA group poll EOL Resistance: Not used Temperature Range: 32°F to 120°F (0°C to 49°C) Humidity: 10% to 93% Non-condensing Dimensions: 41/2" H x 4" W x 11/4" D (Mounts to a 4"square by 21/8" deep box.) Accessories: SMB500 Electrical Box BEFORE INSTALLING MOUNTING This information is included as a quick reference installation guide. Refer to The SK-Relay mounts directly to 4-inch square electrical boxes (see Figure the appropriate Silent Knight control panel installation manual for detailed 2A). The box must have a minimum depth of 21/8 inches. Surface mounted system information. If the modules will be installed in an existing operational electrical boxes (SMB500) are available from Silent Knight. system, inform the operator and local authority that the system will be tern- FIGURE 2A. MODULE MOUNTING FIGURE 2B: porarily out of service. Disconnect power to the control panel before installing WITH BARRIER: the modules. NOTICE: This manual should be left with the owner/user of this equipment. ! ... ' ® 4 Ca GENERAL DESCRIPTION _ The SK-Relay is intended for use in intelligent, two-wire systems where the in- 1�� , �"�� dividual address of each module is selected usingthe built-in rotaryswitches. . �`' ♦ '��� \I J) It allows a compatible control panel to switch discrete contacts by code com 4 I \F' mand. The relay contains two isolated sets of Form-C contacts, which operate ��� _ �� 1 as a DPDT switch and are rated in accordance with the table in the manual. ,,� Circuit connections to the relay contacts are not supervised by the module. The module also has a panel controlled LED indicator. COMPATIBILITY REQUIREMENTS To ensure proper operation, this module shall be connected to a compatible e Silent Knight system control panel (list available from Silent Knight). litelfr ^^, `` FIGURE 1. CONTROLS AND INDICATORS: - i , I .‹ ., -- 1 - , El - --•.-:,.:.„„_,_ , ij :int Q e oP1 T11 0 I� o0411110,.C' IIt I'll T10 TI Z C c 00° le T9 T2 C1070-00 II} WIRING T8 T3 NOTE: All wiring must conform to applicable local codes, ordinances, and reg- ulations. When using control modules in nonpower limited applications, the I�}_T7 5 : 7 8 910 5 ; 7 8 a T4E CB500 Module Barrier must be used to meet UL requirements for the separa- 1151 17 T6 4`ate• II 4� T5 tion of power-limited and nonpower-limited terminals and wiring. The barrier 2 t2 2 ,1 must be inserted into a 4" x 4" x 2'/8"junction box, and the control module 106 I 0 must be placed into the barrier and attached to the junction box (Figure 2A). = .TENS 8 OI1ES p The power-limited wiring must be placed into the isolated quadrant of the - module barrier (Figure 2B). CI D 1. Install module wiring in accordance with the job drawings and appropri- iLOOP ADDRE I ate wiring diagrams. J i 2. Set the address on the module per job drawings. 3. Secure module to electrical box (supplied by installer), as shown in C1071-00 Figure 2A. SK-470-001 1 156-3438-001 Relay Contact Ratings: CURRENT RATING MAXIMUM VOLTAGE LOAD DESCRIPTION APPLICATION 3 A 30 VDC Resistive Non-coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-coded .9 A 125 VDC Resistive Non-coded .5 A 30 VDC Inductive(UR=5ms) Coded 1 A 30 VDC Inductive(UR=2ms) Coded .3 A 125 VAC Inductive(PF=.35) Non-coded 1.5 A 25 VAC Inductive(PF=.35) Non-coded .7 A 70.7 VAC Inductive(PF=.35) Non-coded 2 A 25 VAC Inductive(PF=.35) Non-coded AWARNING All relay switch contacts are shipped in the standby state (open) state,but may have transferred to the activated(closed) state during shipping.To ensure that the switch contacts are in their correct state,modules must be made to communicate with the panel before connecting circuits controlled by the module. FIGURE 3.RELAY MODULE WIRING DIAGRAM: CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY TO NEXT"n11( OR DEVICE t (—) �� \ 4. FROM PANEL VI (+)�00 + PREVIOUS DEVICE CONTROL I $ SIGNAL LINE CIRCUIT(SLC) MODULE 32 VDC MAX. f-1 (-1 $ $ TWISTED PAIR ,.,IO O , IS RECOMMENDED `�'�AL e o T1 © _ RELAY COMMON 2 -no n il (+) IF ANY WIRING TO TERMINALS 4—10 IS NONPOWER NORMALLY CLOSED 2 ±I' LIMITED,THE CB500 BARRIER IS REQUIRED.THE CB500 NORMALLY OPEN 2 INCLUDES A NONPOWER LIMITED LABEL,WHICH MUST RELAY COMMON 1 n r ;il'l UNUSED BE PLACED OVER THE POWER LIMITED TERMINAL NORMALLY CLOSED ` TO NORMALLY OPEN 1 INFORMATION ON THE NAMEPLATE LABEL. 49 O O MODULE DOES NOT SUPERVISE CONTROLLED CIRCUITS *NOTE:ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE. C0946-00 SK-470-001 2 I56-3438-001 ©2009 Honeywell International Inc. - hwrz Ultratech Power Products UT 1270 12V 7Ah Sealed Lead Acid Alarm Battery Which alarm batteries do technicians, installers, and security professionals choose when buying 12 Volt 7 Amp Hour SLA Backup Alarm Batteries? UltraTech Power Products UT 1270, time and time again. UltraTech Power Products is known to be the most reputable brand in the country. When choosing a 12 Volt 7 Amp Hour SLA battery, the UltraTech UT 1270 is the ideal backup power source. Here are a few reasons the UT 1270 (commonly known as the IM-1270) is recognized as the best in the industry: • 2 Year Manufacturer's Warranty - (Covers Defect Only, not Lifespan) • Highest quality parts in the industry: ISO 9002 Certified • Easy Installation • Rechargeable • Non-Spillable: Can be operated in any position without leakage This battery is the direct replacement for all previous versions of UltraTech UT1270. Ultratech batteries are often found in burglar alarm systems, fire alarm systems, access control systems, low-voltage lighting, uninterruptible power supplies (UPS) systems, as well as other security and battery backup applications. Both Residential and commercial Alarm panels made by Honeywell Ademco, Napco, DSC and GE are common applications of the UltraTech UT 1270. The UT1270 is also used to replace existing 12V 7AH batteries found in UPS and Battery Backup Systems. Terminals: Fast-on F1 (0.187") Connectors Click Here for the UT 1270 Spec Sheet Battery Specifications: 20Hr. rate of 0.35A to 10.5V 7Ah 10Hr. rate of 0.65A to 10.5V 6.5Ah 5Hr. rate of 1.20A to 10.2V 6Ah 1 Hr. rate of 4.20A to 9.6V 4.2Ah Weight (approx.): 5.42 pounds (2.46kgs.) Energy Density (20Hr. rate) - 1.46WH/cubic inch (89.4WH/ liter) Maximum Discharge Current with Standard Terminals - 35A Amperes Charge Retention (shelf life) at 60° F (20° C) : 1 Month 97% 3 Month 91% 6 Month 85% Life Expectancy: Standby use - 3 to 5 years Cycle use (approx.) - 100% Depth of Discharge 250 cycles, 50% Depth of Discharge 550 cycles, 30% Depth of Discharge 1200 cycle. (R,ATI) Area of Refuge & Elevator Landing Communication Systems Power Supply 2500-PWR24U Recognized Component G�,sTEE Intertek Conforms to UL STD 2017 Dimensions: • 8.78" H x 12.29" W x 2.81" D Input: • 100-120vac, 50/60Hz, 4.0A Output: • 24vdc @5A total continuous output • Filtered and electronically regulated output • 12 PTC protected outputs @0.500A current limited • Class 2 • 24vdc adjustable output • 24vdc S1 on/off switch • Input and output status LED indicators Protection: • Short Circuit/Overload/Over Voltage Supervision: • DC power failure supervision (form C contacts) Environmental: • For indoor use ONLY • Operating temperature 32° F to 120° F (0° C to 49° C) ambient N56W24720 N. Corporate Circle • Sussex, WI 53089 01/19 800-451-1460 • www.RATHCommunications.com MADE IN THE USA 1: RAT.} Area of Refuge & Elevator Landing Communication Systems ® 2100-958NSR SmartRescue System Call Box Y • • EMERGENCY PHONE • •• • SOLID LIGHT:CALLING •• BLINKING LIGHT:RECEIVED If Face Plate Size: 9-1/2" H x 7-1/2" W Back Box Size: 8" H x 6" W x 3" D Style: Brushed Stainless Steel, Flush Mount Options: Strobe Interface & Relay, Mushroom Push Button Features: • Meets all IBC, ADAAG, and NFPA code requirements • Requires analog telephone line (POTS, PBX, or central office line) • Power Requirements: 24vdc from model 2500-PWR24U • 7.2V 300mAH battery (part# RP7300110) • Built-in battery backup recharges from 24vdc power(allows for a minimum of 4 hours of talk time upon power loss) • Built-in 10 phone consolidator feature allows you to install 10 Call Boxes and 1 Base Station on a single telephone line • Programmable with up to 5 emergency numbers • On-site programming • Remote or on-site diagnostic test • Recordable location message (18 seconds) • Phone checks every 24 hours for an active phone line, if one is not detected, phone will provide a relay trip • Compatible with SmartRescue Base Station or Command Center for in-building rescue coordination • Automatic dialer (31 digit programmable memory) • Automatic answer feature with audible ring • Touch Tone operation only (Touch Tone is an AT&T registered trademark) • 3 year warranty N56W24720 N. Corporate Circle • Sussex, WI 53089 01/19 800-451-1460 • www.RATHCommunications.com IN THE USA 1 YEAR WARRANTY Cia0)RATEL Area of Refuge 8 Elevator Landing Communication Systems SmartRescue Base Station 2500-205B • r -...Size: 15.07" H x 12" W x 6" D Style: • Powder coated steel enclosure • Surface mount • Twist lock closure for use with Fireman's lock (not provided) • Coil cord Features: • Use with up to 5 Call Boxes on the same telephone line • Run twisted and shielded 4 wire set from each Call Box to Base Station unit and one standard phone line to outside world • Can be installed on an IP phone system when used with our 2100-VOIP Interface Device • Easy to use push buttons • Passively monitor communications between Call Boxes and outside world via the LEDs: 1. Solid lit LED indicates there is an emergency call in progress 2. Slow blinking LED indicates there is a call on hold • Audible alert when Call Box initiates call, silenced when call is joined from Base Station • Includes relay contact that trips if any Call Box has been activated • Includes connections for(2) Sub-Stations • The Base Station is able to: 1. Call into all or individual Call Boxes as needed 2. Join existing conversations between Call Boxes and outside world 3. Hang up and original conversation will continue 4. Terminate outside world so it is only talking to the Call Boxes or terminate the call with all parties entirely • Volume control handset meets ADA requirements • Designed for either 120vac or 24vdc power • 16.8V 1400mAH battery (part# RP7300109A) • Built-in battery backup recharges from 120vac or 24vdc power (allows for a minimum of 4 hours talk time upon loss of power) • Telephone Line Voltage: 24v-48v • Meets all IBC, ADAAG, and NFPA code requirements • 3 year warranty N56W24720 N. Corporate Circle • Sussex, WI 53089 08/19 800-451-1460 • www.RATHCommunications.com MADE IN THE USA '1 VFAN WARRANTY