HomeMy WebLinkAboutPermit File 2200 20th Place ANACORTES PUBLIC WORKS DEPARTMENT
Steven Lange, Project Manager
P.O.BOX 547,ANACORTES,WA 98221 PH(360)661.3468
E-MAIL:stevel@cityofanacortes.org FAX(360)293-1938
Memo
Date: November 13,2007
To: Dale Herrigstad, PE
From: Steven Lange
Subject: Submitted Revisions, Dated 11-09-07—Sheet 3(PW#06-074-DEV)
cc: Eric Shjarback, Fred Buckenmeyer, Dave Walde, Jim Baldwin
A review was completed on November 13, 2007 of the submitted revised Sheet 3 of 4 on
November 9, 2007.
The proposed revisions require an Encroachment Agreement, per the City of Anacortes
Encroachment Ordinance, to be in the Public Right-of-Way. The fill area above the Cul-
de-Sac fill slope and key, including the retaining wall and asphalt parking lot shall be
considered-an encroachment.
An Encroachment Agreement can be obtained by Marc Krueger at the Maintenance and
Operations Facilities, located at 37th and D Avenue. Marc can be reached by calling
360.293.1921 if you have any questions regarding the encroachment agreement
process.
A review copy of the submitted sheet will be available for pick up at the front counter in
the Engineering/Building Departments. If you have any questions, please contact me at
360.661.3468.
Sincerely,
teven ange
Project Manager
ANACORTES PUBLIC WORKS DEPARTMENT
Steven Lange, Project Manager
P.O.BOX 547,ANACORTES,WA 98221 PH(360)661.3468
4,22
E-MAIL:stevel@cityofanacortes.org FAX(360)293-1938
Memo
Date: December 11,2007
To: Don Measamer
From: Steven Lange
Subject: Structural Calculation Review Retaining Wall—11-27-07(PW#06-074-DEV)
cc: Eric Shjarback
A review was completed on December 11, 2007 of the Site Plan, dated December 10,
2007, that was submitted with the Structural Calculations for the D Avenue Duplex Site
Retaining Walls, dated December 6, 2007. Below are the follow comments:
1. An Encroachment agreement is required. The encroachment shall include: A)
The parking lot B) Fill placement above the 2:1 slope from the Cul-de-Sac to the
Key at the toe of slope C) Concrete Retaining Wall.
2. The Storm Drainage system along the east boundary line, as well as the
drainage from the parking lot will need to be redesigned from the original
approval.
3. The Retaining Wall, under this design is uphill from the proposed Storm Drainage
system along the east boundary line. There needs to be a 20-foot minimum
clearance between the Storm System and the retaining wall for future
maintenance needs.
Please give the applicant a copy of this letter and the enclosed documents. If you have
any questions, please contact me at 360.661.3468.
Sincerely, j
Steven Lange
Project Manager
Enclosed: 177 S�-
1. Letter, dated November 1-1', 2007 to Dale regarding review of wall layout.
2. Encroachment Agreement.
I 1 7-1....____— I
/RE: rAIN
_ I �� r DOES NO1
10 PUBLIC UTI' ITY, ROAD & SW ESMT 1, 1 o TO SW NU
4 ATER METE
/ r,�g/ ,� ROW
LL
BD ES 1 APS 00 9 .,
EX, . PP '' ;y _W. _ 40 LF .811 CPE
�, / SLUPE-0,2092
::ERE ® 7 \ '' / I ,,
i - _-. _— CB TYPE2
CB TYPL2
411 RIM ELEV,-= 125:591
►
RIM :LEV,-y
'w.' At, 2 0 I ' 3,yN89 26 14 INV, EL EV,TNN , 120,50` �1 - _ If INV, ELEVE=
I , -T RE T
�0.
� ,
r A A. ., \ Afr ,, .JNC,
YP ,..' AIL VAX I
,fir{.- Y.Y""-
mci
.' .. :, '' ' L--160 LF 12'
..
;frat
6" PV �. 84,00 —
' 1 .. �'g.;, ,00` SLOPE:-,177
\,.. _i
10 PUB IC UTILITY — — — —
READ ; .... .MT
I7 '-- . - - 18'X6" S
6 SD
SIDE 'iI Ln
I
60,5 FIR HYDRANT ASSYt SIDE co ` -- 611 SS -1-�--- I _I I .
I 8X TEE FLXf LXEI Im SIDE 1 lI �--,
c° 6 VALVE. I 1 z I
w ,
o� 8� JXF L
( RN rAP F-I n1 1 ,,., I , I f 1 ,