Loading...
HomeMy WebLinkAboutBLD-2026-0148 - RESIDENTIAL REMODELPlease request inspections online through the permit portal. If that is not possible please call (360) 293-1901 for Building or Planning inspections. For Public Works inspections, please call (360) 293-1938. PARCEL: P126714 LEGAL DESCRIPTION: LOT 7, THE WOODS AT SUNSET COVE, ACCORDING TO THE PLAT THEREOF, RECORDED OCTOBER 17, 2007, UNDER AUDITOR'S FILE NO. 200710170081, RECORDS OF SKAGIT COUNTY, WASHINGTON. APPLICANT: Hatfield, George 2709 Strom Place Anacortes, WA 98221 3605433220 OWNER: HATFIELD PATRICIA LOUISE HATFIELD GEORGE MICHAEL ANACORTES, WA 98221 VALUATIONS: Estimated construction cost 3000.00 $3,000.00 $3,000.00Total: FEES:Paid Due Building Permit Fee $83.25 $0.00 Plan Review Fee $54.11 $0.00 State Building Code Council fee $6.50 $0.00 $0.00Totals : REQUIRED INSPECTIONS Building Final $143.86 BLD-2026-0148 RESIDENTIAL REMODEL WITH NO NEW SQ FOOTAGE ISSUED: EXPIRES: 03/11/2026 03/11/2028 PROJECT NAME: PONY WALL SHEATHING SITE ADDRESS: 2709 STROM PLACE ANACORTES Page 1 of 1Printed by : Jennifer Watson on: 03/24/2026 12:16 PM City of Anacortes, WA 904 6th Street Anacortes, WA 98221 (360) 293-1901 http://cityofanacortes.org/ 36" 3'-2 1/4" 0'-6" 16" SIMPSON HANGER 1/2" X 10" A.B. 48" O.C. W/ 3" X 3" BEARING PLATE R-21 INSULATION 1 TYPICAL 6" FOUNDATION WALL 2 X 6 WALL 7/16 OSB SHEATHING 1/2" SHEETROCK 3/4" OSB SUBFLOOR2 X TREATED PLATE SILL SEAL #4 VERT. "L" REBAR 48" O.C. (2) GRADE 40 # 4 HORZ. REBAR (2) GRADE 40 #4 REBAR 8" CONCRETE WALL SCALE: 3/4" = 1' SIDING TYVEK HOUSE WRAP INSTALL 6 MILL BLACK VAPOR BARRIER OVERLAP JOINTS 12" NOTE: JOISTS MAY RUN PERPENDICULAR TO DIRECTION SHOWN. NOTE: FOUNDATION WALL HEIGHTS MAY VARY DEPENDING ON FINAL GRADE 5/8" +/- WASHED DRAIN ROCK 4" PERFORATED PVC FOOTING DRAIN R-30 INSULATION 11 7/8" BCI FLOOR JOIST NOTE: FOUNDATION WALL HEIGHTS MAY VARY DEPENDING ON FINAL GRADE 16" 24" 6" R-21 INSULATION NOTE: JOISTS MAY RUN PERPENDICULAR TO DIRECTION SHOWN. NOTE: FOUNDATION WALL HEIGHTS MAY VARY DEPENDING ON FINAL GRADE SCALE: 3/4" = 1' 6" CONCRETE WALL 7/16 OSB SHEATHING 2 X 6 WALL 1/2" X 10" A.B. 48" O.C. W/ 3" X 3" BEARING PLATE 2 X TREATED PLATE #4 VERT. "L" REBAR 48" O.C. (2) GRADE 40 #4 HORZ. REBAR 5/8" +/- WASHED DRAIN ROCK 4" PERFORATED PVC FOOTING DRAIN (2) GRADE 40 #4 REBAR 2 TYPICAL 6" FOUNDATION WALL @ GARAGE SILL SEAL SIDING TYVEK HOUSE WRAP 4" CONC. SLAB OVER 6 MIL VAPOR BARRIER ON GRANULAR FILL NOTE: FOUNDATION WALL HEIGHTS MAY VARY DEPENDING ON FINAL GRADE 1/2" SHEETROCK 16" 24" 6" 6" CONCRETE WALL SCALE: 3/4" = 1' GARAGE DOOR #4 VERT. "L" REBAR 48" O.C. (2) GRADE 40 # 4 HORZ. REBAR 5/8" +/- WASHED DRAIN ROCK 4" PERFORATED PVC FOOTING DRAIN (2) GRADE 40 #4 REBAR BUCK OUT FOR GARAGE DOOR 3 TYPICAL FOUNDATION WALL @ GARAGE DOOR 4" CONC. SLAB OVER 6 MIL VAPOR BARRIER ON GRANULAR FILL NOTE: FOUNDATION WALL HEIGHTS MAY VARY DEPENDING ON FINAL GRADE 36" 0'-6" 16" #4 VERT. "L" REBAR 48" O.C.(2) GRADE 40 # 4 HORZ. REBAR (2) GRADE 40 #4 REBAR 6" CONCRETE WALL INSTALL 6 MILL BLACK VAPOR BARRIER OVERLAP JOINTS 12" 11 7/8" BCI FLOOR JOIST SILL SEAL 4" CONC. SLAB OVER 6 MIL VAPOR BARRIER ON GRANULAR FILL SCALE: 3/4" = 1' 1/2" X 10" A.B. 48" O.C. W/ 3" X 3" BEARING PLATE 4 TYPICAL 6" FOUNDATION WALL AT GARAGE R-21 INSULATION 1/2" SHEETROCK 2 X 6 WALL 1/2" SHEETROCK 3/4" OSB SUBFLOOR2 X TREATED PLATE NOTE: JOISTS MAY RUN PERPENDICULAR TO DIRECTION SHOWN. NOTE: FOUNDATION WALL HEIGHTS MAY VARY DEPENDING ON FINAL GRADE R-30 INSULATION SIMPSON HANGER 1/2" X 6" A.B. 48" O.C. W/ 3" X 3" BEARING PLATE TREATED SOLE PLATE 2 X 6 STUDS 16" O.C. WITH DOUBLE TOP PLATE. 3/4" OSB 11 7/8" BCI JOISTS R-30 INSULATION 6" X 16" CONC. FOOTING W/ (2) GRADE 40 # 4 HORZ. REBAR 6 MILL VAPOR BARRIOR 5 FLOOR SUPPORT - PONY WALL SCALE: 3/4" = 1' CONTINUOUS BLOCKING 8" 18" 2'-0" (4) GRADE 40 #4 REBAR EACH WAY 6 FOOTING W/ SONOTUBE SCALE: 3/4" = 1' 6 X 6 P.T. POST (4) GRADE 40 #4 REBAR VERT. HOOKS 12" SONO-TUBE CB66 POST BASE 18" MIN. BELOW GRADE SCALE: 3/4" = 1' 7 LATERAL RESTRAINT PANEL (LRP) 2X SINGLE TOP PLATE RAFTERS TIE @ 24" O.C. (IF TRUSSES BEAR ON HEADER) HEADER PER PLAN END OF HEADER (2) 2 X STUDS & SILL PL. 7/16" OSB SHEATHING FASTEN SHEATHING TO HEADER WITH 8D NAILS IN A 3" GRID AS SHOWN AND 3" O.C. IN ALL FRAMING (STUDS & SILLS). SIMPSON HDU2 SIMPSON SSTB20 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO OF: PAGE: BUILDER INFO: A4 MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout J. SYKORA, CPBD THE WOODS - LOT 7 ANACORTES WA 98221 PHONE: 360-293-7431 WEB: www.strandbergconstruction.com DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLING FOUNDATION DETAILS FOUNDATION DETAILS CONSIDER SHEATHING ONE SIDE OF PONY WALL WITH 7/16" OSB WITH 8D NAILS @ 6" O.C., USE 8' LONG SHEET AND SKIP EVERY OTHER 8' SECTION NOT TO SCALE NOT TO SCALENOT TO SCALE Nail Boise Rimboard nail into each flange. to BCI joist with 8d NOT TO SCALE NOT TO SCALE NOT TO SCALE 1 TOP PLATE HANGER NOT TO SCALE BEND TAB AND FASTEN WITH 10dx1 1/2" NAILS WHEN WEB STIFFENERS ARE NOT USED Simpson Strong-Tie ITS11.88 30 LB FELT OR SUITABLE BARRIER TO BE USED BETWEEN HANGER AND ACQ-D & CA-B TREATED SILL SILL SEAL Floor Joist Blocking per IRC 502.7 (Seismic Design Categories D1 & D2) NOT TO SCALE Beam width shall exceed Versa-Lam or Boise GLULAM Beam: Joist hanger Face Mount 2x specified hanger nail length ® Boi s e Ri mb o a r d Boi s e Ri mboar d ® into each flange. or rimboard closure. 23/32" min. plywood/OSB Nail with 8d nails required for cantilever. BCI joist blocking® 2 CONTINUOUS BLOCKING NOT TO SCALE (WALL OR BEAM)Nailing per local code provisions Blocking BCI Joist Intermediate Bearing NOT TO SCALENOT TO SCALE Nail Boise Rimboard nail into each flange. to BCI joist with 8d NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE Floor Joist Blocking per IRC 502.7 (Seismic Design Categories D1 & D2) NOT TO SCALE Beam width shall exceed Versa-Lam or Boise GLULAM Beam: Joist hanger Face Mount 2x specified hanger nail length ® Boi s e Ri mb o a r d Boi s e Ri mbo a r d ® into each flange. or rimboard closure. 23/32" min. plywood/OSB Nail with 8d nails required for cantilever. BCI joist blocking® 4" CONCRETE SLAB SLOPE GARAGE FLOOR 10'-3 1/2"11'-10"14'-2" 18'-6 1/2"5'-5 1/2"5'-9"11'-10"13'-10"6'-7" 14'-2" 17'-9" 14'-7" 53'-6" 53'-6" 31'-5 1/2" 0'-6 1/2" 24'-0" 29'-6" 86'-0" 14'-5 1/2" 86'-0" 14'-5"10'-9 1/2"6'-9 1/2"5'-5 1/2"18'-6 1/2" 3'-8" 10'-11" 4'-5" 8'-7 1/2" 3'-10" 1'-6" 2'-6" 1'-5"11'-10"10'-8 1/2" 6'-0"32'-0"24'-0"24'-0" 6'-0"13'-0"23'-11 1/2"7'-0 1/2"36'-0" 7'-0" 3'-0" 11'-6" 18'-0" 14'-0" 1 A4 3 A4 2 A4 SSTB20 HDU2 2 2 A4 3 A4 2 A4 2 A4 4 A4 2 X 6 PONY WALL 2 X 6 PONY WALL 5 A4 2 X 6 PONY WALL 5 A4 STEP IN STEMWALL STEP IN STEMWALL SIMPSON HANGERS 1 A52 A5 SIMPSON HANGERS A5 2 A5 2MAIN FLOOR FRAMING PLAN SCALE: 1/4" = 1' A5 2 A4 1 BCI 6000 1.8 "I" JOISTS 16" O.C. SIMPSON HANGERS SIMPSON HANGERS SIMPSON HANGERS 1 A5 1 A5 2 X 6 PONY WALL 2 X 6 PONY WALL 6 A4 6 A4 6 A4 A4 5 A4 1 A4 1 A4 1 A4 1 A4 A4 1 A4 1 SSTB20 HDU2 1 A4 1 A4 5 A4 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 LRP (7/A4)LRP (7/A4) A4 6 A4 6 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO OF: PAGE: BUILDER INFO: A5 MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout J. SYKORA, CPBD THE WOODS - LOT 7 ANACORTES WA 98221 MAIN FLOOR FRAMING PLAN PHONE: 360-293-7431 WEB: www.strandbergconstruction.com DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLINGCOORDINATE W/ MECH. & ELEC. FOR LOCATIONS & SIZES OF FOUNDATION/SLAB/ JOISTS BLOCKOUTS. REFER TO SHEET A3 & A4 FOR FOUNDATION NOTES AND DETAILS. 2. 1. FLOOR JOIST OR ROOF TRUSS/RAFTER LAYOUT SHOWN HERE IS FOR SCHEMATIC DESIGN ONLY. MANUFACTURER SHALLPROVIDE AND SUBMIT ENGINEERED DESIGN TO THE BUILDING DEPARTMENT FOR APPROVAL PRIOR TO THE FABRICATIONAND INSTALLATION. 3. ALL TRUSS TO TRUSS & TRUSS TO BEAM CONNECTORS TO BE DESIGNED BY MANUF. 4. FLOOR SHEATHING TO BE 3/4" CDX OR OSB STURDI-FLOOR T&G, GLUE AND NAIL W/ RING SHANK 8d's @ 6" EDGES & 12" IN THEFIELD. FACE GRAIN PERPENDICULAR TO SUPPORTS. ROOF SHEATHING TO BE 7/16" OSB OR EQUAL. 5. PROVIDE SOLID BLOCKING IN THE JOIST CAVITY BENEATH ALL POST LOCATIONS AND BETWEEN UPPER AND LOWER STUDS AT FLOOR TO FLOOR HOLDOWN LOCATIONS. 6. PROVIDE BLOCKING BETWEEN I-JOISTS AT INTERIOR BEARING LOCATIONS WHERE THERE IS A LOAD BEARING WALL ABOVE. 7. 8.ALL CONNECTIONS TO BE SIMPSON OR EQUAL. FRAMING NOTES ALL HEADER MATERIAL TO BE 4 X 10 D.F. # 2 U.N.O. ALL DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE. 2. 1. ALL EXTERIOR WALLS ARE 2x6 - 16" O.C. STUDS, UNLESS NOTED OTHERWISE. 3. ALL INTERIOR WALLS ARE 2x4 - 16" O.C. STUDS, UNLESS NOTED OTHERWISE. 4. PROVIDE BACKING IN ALL BATHROOMS FOR TOWEL BARS, TOILET PAPER DISPENSERS, MEDICINE CABINETS, ETC. COORDINATE WITH OWNER FOR LOCATIONS. 5. GENERAL NOTES CONSIDER SHEATHING ONE SIDE OF PONY WALL WITH 7/16" OSB WITH 8D NAILS @ 6" O.C., USE 8' LONG SHEET AND SKIP EVERY OTHER 8' SECTION CONSIDER SHEATHING ONE SIDE OF PONY WALL WITH 7/16" OSB WITH 8D NAILS @ 6" O.C., USE 8' LONG SHEET AND SKIP EVERY OTHER 8' SECTION 1100--0066--1155 COVER SHEET THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. A1 PROJECT DESCRIPTION NEW SINGLE FAMILY RESIDENCE ZONING TYPE: R-2 FIRE RATING: NOT RATED CODE COMPLIANCE ALL CONSTRUCTION TO COMPLY WITH LOCAL CODES AND ORDINACES AND THE FOLLOWING: - 2012 INTERNATIONAL RESIDENTIAL CODE - 2012 WASHINGTON STATE ENGERGY CODE DEFERRED SUBMITTALS 1.MECHANICAL HVAC SYSTEM DRAWINGS 2.ELECTRICAL POWER DISTRIBUTION DRAWINGS 3.NATURAL GAS DISTRIBUTION DRAWINGS 4.PLUMBING DRAWINGS 5.ROOF TRUSS DRAWINGS / CALCULATIONS 6.FLOOR JOIST DRAWINGS / CALCULATIONS 7.LANDSCAPE PLANS 8.LIGHTING PLANS 9.CABINET SHOP DRAWINGS 10.CUSTOM HARDWARE / BRACKET SHOP DRAWINGS INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO DESIGN INFORMATION BUILDER: STRANDBERG CONSTRUCTION, INC. P.O. BOX 319 ANACORTES WA 98221 360-293-7431 DESIGNER: JIM SYKORA CPBD - STRANDBERG CONSTRUCTION INC. JIM@STRANDBERGCONSTRUCTION.COM PROJECT INFORMATION OF: PAGE: BUILDER INFO: PROJECT ADDRESS: PARCEL #: P126714 BUILDING SQUARE FEET MAIN FLOOR: 1,633 SQ.FT. UPPER FLOOR: 694 SQ.FT. GARAGES: 932 SQ.FT. FOUNDATION DETAILS TOTAL LIVING AREA: 2,327 SQ.FT. FIRE AREA: 3,588 SQ. FT. 2709 STROM PLACE ANACORTES WA 98221 FIRE FLOW REQ. = N/A NEAREST HYDRANT = N/A THE WOODS - LOT 7 2709 STROM PLACE ANACORTES, WA 98221 SHEET INDEX COVER SHEET A2 SITE PLAN A3 FOUNDATION PLAN A4 A1 A5 MAIN FLOOR FRAMING PLAN MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout A6 MAIN FLOOR PLAN A7 UPPER FLOOR FRAMING PLAN A8 A9 J. SYKORA, CPBD THE WOODS - LOT 7 A10 LOWER ROOF FRAMING PLAN A11 ANACORTES WA 98221 PHONE: 360-293-7431 WEB: www.strandbergconstruction.com DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLING A12 BUILDING SECTIONS A13 EXTERIOR ELEVATIONS A14 EXTERIOR ELEVATIONS A15 ENGINEERING INFO BID DATE PERMIT DATE CONTRACT DATE CHANGE 1 CHANGE 2 CHANGE 3 COVERED ENTRY: 176 SQ. FT. COVERED PORCHES: 153 SQ. FT. DRAFTSMAN: JASON STERLING - STRANDBERG CONSTRUCTION INC. JASONS@STRANDBERGCONSTRUCTION.COM UPPER FLOOR AND ROOF PLAN BUILDING SECTIONS N 4 2 . 5 8 ' 20.00' 32.06' 100.53' 55.92' 91.31' 39.44' 76.69' 36.29' S S S S S S S S S S S S S S S S S S S 30.01' 12'-0" 5'-0" 5'-0" 5'-0" 10'-0" 10'-0" 5'-0" 5'-0" 25.88' 6.18' 30.51' 3.10'5 7.5 0' 1 0 % S L O P E S T R O M P L A C E LOT 9 P126722 P126716 STORM DRAIN 5' SETBACK 5' S E TBA C K 5' SETBACK 5' S E T B A C K10' SETBACK 2 0 ' S E T B A C K 1 0 ' U T I L I T Y E A S E M E N T DRIVEWAY 781 SQ.FT. 6,703 SQ.FT. S E PTIC LIN E WATER METER PROPOSED SFR SEWER CONNECTION GARAGE 6 STORM DRAIN 10' DRAINAGE EASEMENT LOT 7 FENCE FENCE FENCE 25' 18' 5' SIDE SETBACK 5' SIDE SETBACK 5 ' S I D E S E T B A C K SEWER WATER METER DRIVEWAY GARAGE SFR FENCE 5' SIDE SETBACK 10' UTI LI T Y EASEMENT 6" OFFSET PATIO 2 0 ' S TR E E T SE TB A CK 10' REAR SETBACK 10' REAR SETBACK STORMWATER PATIO PATIO P126715 3 3 3 3 2 2 1 3 3 3 2 OK TO SPREAD ROOF AND FOOTING DRAIN NORTH ONTO LAWN IF LOT DRAIN IS TOO HIGH. LOT 8 P126714 P126713 1 0 % S L O P E SOIL STOCKPILE 2 3 3 1 3 SILT FENCE SILT FENCE 3 2 2 2 STR O M PLACE 10' SETBACK 10' SETBACK 5' SETBACK CONCRETE DRIVEWAY 20' SETBACK 1P126708 ALL DOWN SPOUTS AND FOOTING DRAINS TO SPLASH BLOCKS. WATER LINE 1,609 SQ.FT. COVERED ENTRY 96 SQ.FT. COVERED ENTRY 69 SQ.FT. COVERED ENTRY 84 SQ.FT. GARAGE SFR MINIMUM TREE DENSITY ANACORTES MUNICODE - 16.50.070 Calculation of the Total Tree Units Required. The total number of tree units required to be provided by a regulated project or tree conservation permit approval listed in Section 16.50.100 shall be calculated by dividing gross site area, minus any public or private street rights-of-way, by one thousand Table 16.50.120(D). The result of the calculation will be the total number of tree units required for the project approval within the building site. LOT SIZE: 8,059 SQ. FT.TREES REQUIRED: 9 SMALL PARCEL STORM WATER PLAN 1 A) A GRAVEL CONSTRUCTION ROAD SHALL BE INSTALLED WHICH SHALL REMOVE AS MUCH MUD AND DIRT FROM THE VEHICLES AS POSSIBLE PRIOR TO ENTERING THE PUBLIC ROADWAY. THE EFFECTIVENESS AND EFFICIENCY OF THE REMOVAL SHALL BE TO THE SATISFACTION OF THE OFFICIAL. SPSP # 1 CONSTRUCTION ACCESS ROUTESPSP # 1 CONSTRUCTION ACCESS ROUTE B) SEDIMENT TRACKED ONTO THE PUBLIC ROADWAY SHALL BE CLEANED ON AT LEAST A DAILY BASIS. 2 A) ALL EXPOSED SOILS SHALL BE PREVENTED FROM MOVING OFF SITE OR INTO NATURAL OR ARTIFICIAL DRAINAGE SYSTEMS THROUGH SUITABLE APPLICATION OF BMP'S. SPSP # 2 STABILIZATION OF DENUDED AREASSPSP # 2 STABILIZATION OF DENUDED AREAS 3 A) ADJACENT PROPERTIES SHALL BE PROTECTED FROM SEDIMENT DEPOSITION BY APPROPRIATE USE OF VEGETATIVE BUFFER STRIPS, SEDIMENT BARRIERS OR FILTERS, DIKES, BERMS, OR MULCHING. SPSP # 3 PROTECTION OF ADJACENT PROPERTIESSPSP # 3 PROTECTION OF ADJACENT PROPERTIES 4 A) ALL EROSION AND SEDIMENT CONTROL BMP'S SHALL BE INSPECTED AND MAINTAINED REGULARLY BY THE DEVELOPER TO ENSURE CONTINUED PERFORMANCE OF THEIR INTENDED FUNCTION. SPSP # 4 MAINTENANCESPSP # 4 MAINTENANCE 5 A) OTHER APPROPRIATE BMP'S TO MITIGATE THE EFFECTS OF INCREASED RUN-OFF OR INADEQUACY OF ALREADY INSTALLED BMP'S SHALL BE APPLIED AS REQUIRED OR ORDERED BY THE OFFICIAL. SPSP # 5 OTHER BMP'SSPSP # 5 OTHER BMP'S LANDSCAPE LEGEND LAWN AREA CONCRETE DRIVE MULCH - PLANTING BED DECIDUOUS TREE CONIFER TREE SHRUBS / PLANTINGS 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO A2 OF: PAGE: BUILDER INFO: SITE PLAN MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: SITE PLAN SUMMARY PROJECT ADDRESS: 2709 STROM PLACE ANACORTES, WA 98221 PARCEL # P126714 LOT SIZE: 8,059 SQ. FT. BUILDING FOOTPRINT: 2,894 SQ. FT. 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout 1/8" = 1' J. SYKORA, CPBD THE WOODS - LOT 7 ANACORTES WA 98221 PHONE: 360-293-7431 WEB: www.strandbergconstruction.com DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLING 4" CONCRETE SLAB SLOPE GARAGE FLOOR 4" CONCRETE SLAB 4" CONCRETE SLAB 4" CONCRETE SLAB 12'-9" 1'-3" 0'-9" 4'-9"1'-3"0'-9" 10'-3" 1'-3" 0'-9" 6'-0" 53'-6" 14'-5 1/2" 2'-0" 4'-11 1/2" 2'-0" 4'-11 1/2" 7'-0"11'-8"12'-4" 10'-3 1/2"11'-10"14'-2" 5'-4"1'-4"6'-2"1'-4"3'-0"1'-4"12'-6"1'-4"5'-8" 1'-0" 1'-4" 5'-4"1'-4"1'-0"5'-0"1'-6"3'-0"1'-4"12'-6"1'-4"5'-8" 14'-2" 4'-10" 8'-7 1/2" 3'-10" 1'-6" 14'-2" 18'-2" 1'-0" 7'-3" 2'-0" 9'-6 1/2" 2'-0" 9'-0" 1'-2 1/2" 0'-9 1/2" 2'-6" 86'-0" 2'-0"4'-3 1/2"7'-8"10'-10"13'-6"4'-9"1'-3"0'-9" 24'-0"18'-6"5'-6"32'-0"6'-0" 53'-6" 24'-0" 29'-6" 86'-0" 7'-0" 3'-0" 11'-6" 18'-0" 14'-0" 3'-0" 7'-0" 0'-10" 36'-0"31'-0"13'-0"6'-0" 5'-8"3'-1"3'-2"2'-7 1/2"8'-3" 1'-10 1/2"1'-10 1/2" 9'-3"1'-9"9'-3" 1'-10 1/2" GARAGE 932 SQ. FT. BUCKOUT FOR GARAGE DOOR 1 A4 3 A4 2 A4 CRAWLSPACE 1,630 SQ. FT. BUCKOUT FOR GARAGE DOOR FOUNDATION PLAN SCALE: 1/4" = 1' SSTB20 HDU2 CRAWLSPACE VENTILATION CRAWLSPACE AREA: 1,630 SQ.FT. 1,630 / 150 = 10.9 SQ. FT. OF VENT IS REQUIRED. USING 6 X 16 FOUNDATION VENTS, 16 VENTS ARE REQUIRED. ONE SUCH VENTILATING OPENING SHALL BE WITHIN 3 FEET OF EACH CORNER OF THE BUILDING. 2012 IRC - R408.1 FINAL LOCATIONS OF FOUNDATION VENTS TO BE DETERMINED ON SITE. 6" X 16" CONCRETE FOOTING 6" X 16" CONCRETE FOOTING 6" X 16" CONCRETE FOOTING 6" X 16" CONCRETE FOOTING 2 2 A4 3 A4 2 A4 2 A4 4 6" X 16" CONCRETE FOOTING A4 5 A4 5 A4 A4 CRAWLSPACE ACCESS 24" X 30" MIN. 1 18" X 18" X 18" CONCRETE FOOTING 24" x 24" x 8" FOOTING AT FROST DEPTH W/ 12" SONOTUBE TO GRADE. 69 sq ft 84 sq ft 24" x 24" x 8" FOOTING AT FROST DEPTH W/ 12" SONOTUBE TO GRADE. 24" x 24" x 8" FOOTING AT FROST DEPTH W/ 12" SONOTUBE TO GRADE. 24" x 24" x 8" FOOTING AT FROST DEPTH W/ 12" SONOTUBE TO GRADE. 24" x 24" x 8" FOOTING AT FROST DEPTH W/ 12" SONOTUBE TO GRADE. 6 A4 6" THICK WALL 6" THICK WALL 6" THICK WALL 8" THICK WALL 8" THICK WALL 6 A4 6 A4 STEP IN STEMWALL A4 5 A4 1 A4 1 A4 1 A4 1 A4 A4 1 A4 1 SSTB20 HDU2 1 A4 STEP IN STEMWALL 1 A4 5 A4 6" X 16" CONCRETE FOOTING BUCKOUT FOR GARAGE DOOR SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 LRP (7/A4)LRP (7/A4) A4 6 A4 6 LTP5 @ 16" O.C. SHEARWALL SCHEDULE MARK NAILING 2 3 1 4 5 6 8d @ 6" O.C. PNL EDGES SHEATHING 7/16" CD-X OR OSB (1) FACE 7/16" CD-X OR OSB (1) FACE 7/16" CD-X OR OSB (1) FACE 7/16" CD-X OR OSB (1) FACE 7/16" CD-X OR OSB (2) FACE 7/16" CD-X OR OSB (2) FACE 8d @ 12" O.C. PNL FIELD 8d @ 4" O.C. PNL EDGES 8d @ 12" O.C. PNL FIELD 8d @ 3" O.C. PNL EDGES 8d @ 12" O.C. PNL FIELD 8d @ 2" O.C. PNL EDGES 8d @ 12" O.C. PNL FIELD 8d @ 4" O.C. PNL EDGES 8d @ 12" O.C. PNL FIELD 8d @ 3" O.C. PNL EDGES 8d @ 12" O.C. PNL FIELD LTP5 @ 16" O.C. TOP PLATE CONN. LTP5 @ 16" O.C. LTP5 @ 12" O.C. LTP5 @ 10" O.C. LTP5 @ 6" O.C. SOLE PLATE CONN. (2) 16d @ 12" O.C. (2) 16d @ 8" O.C. SDS 25312 @ 10" O.C. SDS 25500 @ 8" O.C. SDS 25500@ 6" O.C. (2) SDS 25500@ 10" O.C. NOTES 1,2,6,9 2,3,6,9 2,3,7,9 2,3,4,8,9 2,3,4,8,9 2,3,4,8,9 NOTES 1. ALL EXTERIOR WALLS TO BE U.N.O.1 2. BLOCK ALL PANEL EDGES. 3. PROVIDE NOMINAL 3 X FRAMING AT ABUTTING PANEL EDGES RECEIVING EDGE NAILING. 4. PROVIDE 3 X SILL PLATE. 5. OFFSET PANEL EDGES. 6. PROVIDE 1/2" A.B. @ 48" O.C. W / 3" X 3" X 1/4" BEARING PLATE WASHER, OR (2) 16d @ 8" O.C. 7. PROVIDE 1/2" A.B. @ 24" O.C. W / 3" X 3" X 1/4" BEARING PLATE WASHER. 8. PROVIDE 1/2" A.B. @ 12" O.C. W / 3" X 3" X 1/4" BEARING PLATE WASHER. 9. STUDS SHALL NOT BE SPACED MORE THAN 16" O.C. SIMPSON HOLD DOWN DETAILS NOT TO SCALE 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO OF: PAGE: BUILDER INFO: A3 MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: FOUNDATION PLAN 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout J. SYKORA, CPBD THE WOODS - LOT 7 ANACORTES WA 98221 PHONE: 360-293-7431 WEB: www.strandbergconstruction.com DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLING 36" 3'-2 1/4" 0'-6" 16" SIMPSON HANGER 1/2" X 10" A.B. 48" O.C. W/ 3" X 3" BEARING PLATE R-21 INSULATION 1 TYPICAL 6" FOUNDATION WALL 2 X 6 WALL 7/16 OSB SHEATHING 1/2" SHEETROCK 3/4" OSB SUBFLOOR2 X TREATED PLATE SILL SEAL #4 VERT. "L" REBAR 48" O.C. (2) GRADE 40 # 4 HORZ. REBAR (2) GRADE 40 #4 REBAR 8" CONCRETE WALL SCALE: 3/4" = 1' SIDING TYVEK HOUSE WRAP INSTALL 6 MILL BLACK VAPOR BARRIER OVERLAP JOINTS 12" NOTE: JOISTS MAY RUN PERPENDICULAR TO DIRECTION SHOWN. NOTE: FOUNDATION WALL HEIGHTS MAY VARY DEPENDING ON FINAL GRADE 5/8" +/- WASHED DRAIN ROCK 4" PERFORATED PVC FOOTING DRAIN R-30 INSULATION 11 7/8" BCI FLOOR JOIST NOTE: FOUNDATION WALL HEIGHTS MAY VARY DEPENDING ON FINAL GRADE 16" 24" 6" R-21 INSULATION NOTE: JOISTS MAY RUN PERPENDICULAR TO DIRECTION SHOWN. NOTE: FOUNDATION WALL HEIGHTS MAY VARY DEPENDING ON FINAL GRADE SCALE: 3/4" = 1' 6" CONCRETE WALL 7/16 OSB SHEATHING 2 X 6 WALL 1/2" X 10" A.B. 48" O.C. W/ 3" X 3" BEARING PLATE 2 X TREATED PLATE #4 VERT. "L" REBAR 48" O.C. (2) GRADE 40 #4 HORZ. REBAR 5/8" +/- WASHED DRAIN ROCK 4" PERFORATED PVC FOOTING DRAIN (2) GRADE 40 #4 REBAR 2 TYPICAL 6" FOUNDATION WALL @ GARAGE SILL SEAL SIDING TYVEK HOUSE WRAP 4" CONC. SLAB OVER 6 MIL VAPOR BARRIER ON GRANULAR FILL NOTE: FOUNDATION WALL HEIGHTS MAY VARY DEPENDING ON FINAL GRADE 1/2" SHEETROCK 16" 24" 6" 6" CONCRETE WALL SCALE: 3/4" = 1' GARAGE DOOR #4 VERT. "L" REBAR 48" O.C. (2) GRADE 40 # 4 HORZ. REBAR 5/8" +/- WASHED DRAIN ROCK 4" PERFORATED PVC FOOTING DRAIN (2) GRADE 40 #4 REBAR BUCK OUT FOR GARAGE DOOR 3 TYPICAL FOUNDATION WALL @ GARAGE DOOR 4" CONC. SLAB OVER 6 MIL VAPOR BARRIER ON GRANULAR FILL NOTE: FOUNDATION WALL HEIGHTS MAY VARY DEPENDING ON FINAL GRADE 36" 0'-6" 16" #4 VERT. "L" REBAR 48" O.C.(2) GRADE 40 # 4 HORZ. REBAR (2) GRADE 40 #4 REBAR 6" CONCRETE WALL INSTALL 6 MILL BLACK VAPOR BARRIER OVERLAP JOINTS 12" 11 7/8" BCI FLOOR JOIST SILL SEAL 4" CONC. SLAB OVER 6 MIL VAPOR BARRIER ON GRANULAR FILL SCALE: 3/4" = 1' 1/2" X 10" A.B. 48" O.C. W/ 3" X 3" BEARING PLATE 4 TYPICAL 6" FOUNDATION WALL AT GARAGE R-21 INSULATION 1/2" SHEETROCK 2 X 6 WALL 1/2" SHEETROCK 3/4" OSB SUBFLOOR2 X TREATED PLATE NOTE: JOISTS MAY RUN PERPENDICULAR TO DIRECTION SHOWN. NOTE: FOUNDATION WALL HEIGHTS MAY VARY DEPENDING ON FINAL GRADE R-30 INSULATION SIMPSON HANGER 1/2" X 6" A.B. 48" O.C. W/ 3" X 3" BEARING PLATE TREATED SOLE PLATE 2 X 6 STUDS 16" O.C. WITH DOUBLE TOP PLATE. 3/4" OSB 11 7/8" BCI JOISTS R-30 INSULATION 6" X 16" CONC. FOOTING W/ (2) GRADE 40 # 4 HORZ. REBAR 6 MILL VAPOR BARRIOR 5 FLOOR SUPPORT - PONY WALL SCALE: 3/4" = 1' CONTINUOUS BLOCKING 8" 18" 2'-0" (4) GRADE 40 #4 REBAR EACH WAY 6 FOOTING W/ SONOTUBE SCALE: 3/4" = 1' 6 X 6 P.T. POST (4) GRADE 40 #4 REBAR VERT. HOOKS 12" SONO-TUBE CB66 POST BASE 18" MIN. BELOW GRADE SCALE: 3/4" = 1' 7 LATERAL RESTRAINT PANEL (LRP) 2X SINGLE TOP PLATE RAFTERS TIE @ 24" O.C. (IF TRUSSES BEAR ON HEADER) HEADER PER PLAN END OF HEADER (2) 2 X STUDS & SILL PL. 7/16" OSB SHEATHING FASTEN SHEATHING TO HEADER WITH 8D NAILS IN A 3" GRID AS SHOWN AND 3" O.C. IN ALL FRAMING (STUDS & SILLS). SIMPSON HDU2 SIMPSON SSTB20 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO OF: PAGE: BUILDER INFO: A4 MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout J. SYKORA, CPBD THE WOODS - LOT 7 ANACORTES WA 98221 PHONE: 360-293-7431 WEB: www.strandbergconstruction.com DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLING FOUNDATION DETAILS FOUNDATION DETAILS NOT TO SCALE NOT TO SCALENOT TO SCALE Nail Boise Rimboard nail into each flange. to BCI joist with 8d NOT TO SCALE NOT TO SCALE NOT TO SCALE 1 TOP PLATE HANGER NOT TO SCALE BEND TAB AND FASTEN WITH 10dx1 1/2" NAILS WHEN WEB STIFFENERS ARE NOT USED Simpson Strong-Tie ITS11.88 30 LB FELT OR SUITABLE BARRIER TO BE USED BETWEEN HANGER AND ACQ-D & CA-B TREATED SILL SILL SEAL Floor Joist Blocking per IRC 502.7 (Seismic Design Categories D1 & D2) NOT TO SCALE Beam width shall exceed Versa-Lam or Boise GLULAM Beam: Joist hanger Face Mount 2x specified hanger nail length ® Boi s e Ri mb o a r d Boi s e Ri mboar d ® into each flange. or rimboard closure. 23/32" min. plywood/OSB Nail with 8d nails required for cantilever. BCI joist blocking® 2 CONTINUOUS BLOCKING NOT TO SCALE (WALL OR BEAM)Nailing per local code provisions Blocking BCI Joist Intermediate Bearing NOT TO SCALENOT TO SCALE Nail Boise Rimboard nail into each flange. to BCI joist with 8d NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE Floor Joist Blocking per IRC 502.7 (Seismic Design Categories D1 & D2) NOT TO SCALE Beam width shall exceed Versa-Lam or Boise GLULAM Beam: Joist hanger Face Mount 2x specified hanger nail length ® Boi s e Ri mb o a r d Boi s e Ri mbo a r d ® into each flange. or rimboard closure. 23/32" min. plywood/OSB Nail with 8d nails required for cantilever. BCI joist blocking® 4" CONCRETE SLAB SLOPE GARAGE FLOOR 10'-3 1/2"11'-10"14'-2" 18'-6 1/2"5'-5 1/2"5'-9"11'-10"13'-10"6'-7" 14'-2" 17'-9" 14'-7" 53'-6" 53'-6" 31'-5 1/2" 0'-6 1/2" 24'-0" 29'-6" 86'-0" 14'-5 1/2" 86'-0" 14'-5"10'-9 1/2"6'-9 1/2"5'-5 1/2"18'-6 1/2" 3'-8" 10'-11" 4'-5" 8'-7 1/2" 3'-10" 1'-6" 2'-6" 1'-5"11'-10"10'-8 1/2" 6'-0"32'-0"24'-0"24'-0" 6'-0"13'-0"23'-11 1/2"7'-0 1/2"36'-0" 7'-0" 3'-0" 11'-6" 18'-0" 14'-0" 1 A4 3 A4 2 A4 SSTB20 HDU2 2 2 A4 3 A4 2 A4 2 A4 4 A4 2 X 6 PONY WALL 2 X 6 PONY WALL 5 A4 2 X 6 PONY WALL 5 A4 STEP IN STEMWALL STEP IN STEMWALL SIMPSON HANGERS 1 A52 A5 SIMPSON HANGERS A5 2 A5 2MAIN FLOOR FRAMING PLAN SCALE: 1/4" = 1' A5 2 A4 1 BCI 6000 1.8 "I" JOISTS 16" O.C. SIMPSON HANGERS SIMPSON HANGERS SIMPSON HANGERS 1 A5 1 A5 2 X 6 PONY WALL 2 X 6 PONY WALL 6 A4 6 A4 6 A4 A4 5 A4 1 A4 1 A4 1 A4 1 A4 A4 1 A4 1 SSTB20 HDU2 1 A4 1 A4 5 A4 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 LRP (7/A4)LRP (7/A4) A4 6 A4 6 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO OF: PAGE: BUILDER INFO: A5 MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout J. SYKORA, CPBD THE WOODS - LOT 7 ANACORTES WA 98221 MAIN FLOOR FRAMING PLAN PHONE: 360-293-7431 WEB: www.strandbergconstruction.com DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLINGCOORDINATE W/ MECH. & ELEC. FOR LOCATIONS & SIZES OF FOUNDATION/SLAB/ JOISTS BLOCKOUTS. REFER TO SHEET A3 & A4 FOR FOUNDATION NOTES AND DETAILS. 2. 1. FLOOR JOIST OR ROOF TRUSS/RAFTER LAYOUT SHOWN HERE IS FOR SCHEMATIC DESIGN ONLY. MANUFACTURER SHALLPROVIDE AND SUBMIT ENGINEERED DESIGN TO THE BUILDING DEPARTMENT FOR APPROVAL PRIOR TO THE FABRICATIONAND INSTALLATION. 3. ALL TRUSS TO TRUSS & TRUSS TO BEAM CONNECTORS TO BE DESIGNED BY MANUF. 4. FLOOR SHEATHING TO BE 3/4" CDX OR OSB STURDI-FLOOR T&G, GLUE AND NAIL W/ RING SHANK 8d's @ 6" EDGES & 12" IN THEFIELD. FACE GRAIN PERPENDICULAR TO SUPPORTS. ROOF SHEATHING TO BE 7/16" OSB OR EQUAL. 5. PROVIDE SOLID BLOCKING IN THE JOIST CAVITY BENEATH ALL POST LOCATIONS AND BETWEEN UPPER AND LOWER STUDS AT FLOOR TO FLOOR HOLDOWN LOCATIONS. 6. PROVIDE BLOCKING BETWEEN I-JOISTS AT INTERIOR BEARING LOCATIONS WHERE THERE IS A LOAD BEARING WALL ABOVE. 7. 8.ALL CONNECTIONS TO BE SIMPSON OR EQUAL. FRAMING NOTES ALL HEADER MATERIAL TO BE 4 X 10 D.F. # 2 U.N.O. ALL DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE. 2. 1. ALL EXTERIOR WALLS ARE 2x6 - 16" O.C. STUDS, UNLESS NOTED OTHERWISE. 3. ALL INTERIOR WALLS ARE 2x4 - 16" O.C. STUDS, UNLESS NOTED OTHERWISE. 4. PROVIDE BACKING IN ALL BATHROOMS FOR TOWEL BARS, TOILET PAPER DISPENSERS, MEDICINE CABINETS, ETC. COORDINATE WITH OWNER FOR LOCATIONS. 5. GENERAL NOTES PLAN AREAS SCALE: 1/4" = 1' MAIN FLOOR GARAGE 1,633 SQ.FT. 932 SQ.FT. COVERED ENTRY 176 SQ.FT. COVERED PORCHES 153 SQ.FT. UPPER FLOOR 694 SQ.FT. TOTAL LIVING AREA:2,327 SQ.FT.2,327 SQ.FT. V Y C O R STEP A - INSTALL TYVEK APRON BELOW WINDOW SILL STEP B - INSTALL VYCOR ACROSS WINDOW SILL STEP C - INSTALL TYVEK FLEX WRAP IN WINDOW CORNERS WINDOW FLASHING INSTALLATION STEP A - INSTALL WINDOW & 4" VYCOR TAPE STEP A - INSTALL TYVEK HOUSE WRAP STEP B - INSTALL TYVEK TAPE STEP # 1STEP # 2STEP # 3 WH W1 2650 SH. W2 3050 SH.W3 3050 SH.W4 3050 SH. W5 3050 SH. W6 6080 PATIO DOOR W7 2660 SH. W8 3016 PIC. W9 3016 PIC. W10 2660 SH. W11 6080 PATIO DOOR W12 3050 SH. W13 2650 SH. W14 1660 SH. 3080 W15 1660 SH. W16 2650 SH. 4068 90809080 2668 W17 2650 SH. 3080 8080 3068 2868 2668 2668 2668 2868 2868 2868 2868 3068 3068 FIREPLACE DIMENSIONS TBD 2668 2668 UP 50 CFM MIN 50 CFM MIN 50 CFM MIN 50 CFM MIN 12 sq ft 78 sq ft 906 sq ft 202 sq ft 35 sq ft 100 sq ft 343 sq ft 83 sq ft 10 sq ft 31 sq ft 22 sq ft 216 sq ft 191 sq ft 25 sq ft 157 sq ft43 sq ft 32'-0" 2'-0" 9'-0" 2'-0" 9'-6 1/2" 2'-0" 2'-2 3/4" 6'-0" 6'-1 1/2"5'-6" 1'-9" 1'-11" 4'-0" 5'-9" 3'-2" 2'-3" 2'-0" 2'-8 1/2"4'-4" 12'-11 1/2" 2'-0"1'-9" 3'-2 7/16" 2'-8" 5'-0 1/2" 2'-0" 2'-0" 4'-11"1'-10" 1'-8 1/4" 2'-0"8'-0"2'-10"3'-0"4'-8"2'-6"1'-0" 6'-11 1/2" 2'-6" 5'-6 3/4" 1'-6" 0'-3" 3'-0" 0'-3"1'-6" 3'-5 3/4" 2'-6" 4'-6" 7'-0"9'-3 1/2"14'-8 1/2" 1'-9 1/2" 3'-0" 1'-8" 5'-5" 1'-4" 3'-0" 1'-9 1/2" 1'-9"3'-0"0'-3"3'-0"0'-3"3'-0"1'-9" 1'-0" 6'-0" 0'-8" 3'-0" 0'-10" 2'-10"2'-6" 0'-8" 2'-10"2'-6" 0'-8" 2'-0" 3'-0" 1'-11" 6'-1" 1'-0" 4'-2" 2'-4 1/2" 2'-1" 2'-1" 2'-4 1/2" 2'-6" 5'-5" 4'-1" 6'-9" 23'-6 1/2"19'-0"5'-11"3'-10" 1'-10" 11'-10 1/2"14'-0" 10'-3"2'-6"18'-3" 2'-0"4'-3 1/4"7'-2"3'-6"7'-4"14'-0" 2'-1" 7'-0" 10'-0 1/2" 4'-5 1/2" 2'-6" 2'-0"9'-0"2'-0"9'-0"2'-0" 14'-0"4'-1"3'-7"3'-2"7'-2"5'-6" 3'-2" 5'-0" 4'-0" 3'-6"3'-0" 9'-0" 7'-1" 5'-8" 5'-9" 5'-8" 6'-0"14'-3 1/2"3'-6"7'-0 1/2"7'-2" 2'-2 1/2"18'-1"4'-4 1/2"2'-4 1/2"4'-10" 3'-9 1/2" 4'-6" 4'-8 1/2" 4'-8 1/2" 5'-4" 4'-0" 0'-7 1/2" 3'-8" 6'-1" 7'-11" 4'-4 1/2" 3'-8" 6'-1 1/2" 86'-0" 6'-0"13'-0"31'-0"36'-0" 14'-0" 18'-0" 11'-6" 3'-0" 7'-0" 53'-6" 86'-0" 24'-0"24'-0"32'-0"6'-0" 53'-6" 24'-0" 29'-6" GARAGE ENTRY KITCHEN MASTER BATH LINEN LAUNDRY BATH SHOWER CLOSET BENCH MASTER BDRM CLOSET / DRESSING FURNACE LIVING DINING TOILET SSTB20 HDU2 4 X 8 @ 96" CLOSET BEARING WALL BEARING WALL BENCH MAIN FLOOR PLAN BEARING WALL ATTIC ACCESS BEARING WALL SCALE: 1/4" = 1' 4 X 8 @ 96" HALL PANTRY CO DET. SMOKE DET. 1 4 X 8 @ 96" SMOKE DET. 1 2 3 6 1098 2 7 11 16 16 10 RISER 7 7/16" RUN 10" COVERED PORCH 84 sq ft 2 4 X 8 @ 96" COVERED PORCH 69 sq ft 17 A10 2 X 6 WALL FOR PLUMBING ABOVE 2 2 1 4 X 8 @ 96" 4 X 10 @ 96" DF.#2 HDR 4 X 8 @ 96" 2 10' CEILINGS 4 X 8 @ 96" 4 X 8 @ 96" 4 X 8 @ 96" 24' LONG 4 X 12 D.F. #2 GARAGE DOOR HEADER 6 X 12 D.F. #2 GARAGE HEADER 4 X 8 @ 96" 4 X 8 @ 96" 4 X 8 HEADER 10 10 A10 1 A11 4 4 A11 5 A11 5 A11 2 2 A10 2 A10 2 3 3 A11 A11 COVERED ENTRY 69 sq ft SSTB20 HDU2 CULTURED STONE BUILT-OUT PILLAR W/ TOP COLUMN 9' CEILINGS 15 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 LRP (7/A4)LRP (7/A4) 9' CEILINGS CULTURED STONE BUILT-OUT PILLAR W/ TOP COLUMN CULTURED STONE BUILT-OUT PILLAR W/ TOP COLUMN 9' CEILINGS 9' CEILINGS 9' CEILINGS9' CEILINGS 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO OF: PAGE: BUILDER INFO: A6 MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout J. SYKORA, CPBD THE WOODS - LOT 7 ANACORTES WA 98221 PHONE: 360-293-7431 WEB: www.strandbergconstruction.com MAIN FLOOR PLAN DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLING ALL HEADER MATERIAL TO BE 4 X 10 D.F. # 2 U.N.O. 20 MIN. FIRE RATED DOOR. FLOOR PLAN NOTES SMOKE DETECTOR. EVERY DWELLING UNIT SHALL HAVE A SMOKE DETECTOR LOCATED IN EVERY BEDROOM AND AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO EACH SEPARATE SLEEPING AREA. IN NEW CONSTRUCTION, REQUIRED SMOKE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. SMOKE DETECTOR AND CO DETECTOR ARE REQUIRED ON EACH LEVEL OF THE STRUCTURE. 1 2 SHELF AND HANGING ROD. BUILT IN SHELVES.3 CABINET - OWNER / CONTRACTOR TO VERIFY.4 EGRESS WINDOWS SHALL HAVE AN OPENABLE SECTION FOR EMERGENCY EGRESS 5.7 SQUARE FEET MIN. MINIMUM NET CLEAR OPENABLE SECTION TO BE 20" WIDE AND 24" HIGH. SILL HEIGHT MAXIMUM 44" OFF FLOOR. 5 WHOLE HOUSE FANS SHALL HAVE A MANUAL CONTROL AND AUTOMATIC CONTROL, SUCH AS A CLOCK TIMER WITH A ZONE RATING OF 1.5 OR LESS.6 F.A.U. ON 18" HIGH PLATFORM. TOP OF PLATFORM TO BE 1 1/8" T & G PLYWOOD. EXPOSED FACE AND SIDES TO HAVE 1 LAYER 5/8" TYPE "X" GYP. BD. NO FURNACE SHALL BE INSTALLED IN ANY CONFINED SPACE WITH ACCESS ONLY THROUGH A BEDROOM, BATHROOM, OR CLOSET. PROVIDE AT LEAST 30" OF WORKING SPACE IN FRONT OF FURNACE.7 ALL BUILDING WATER SUPPLY SYSTEMS IN WHICH QUICK ACTING VALVES ARE INSTALLED, SHALL BE PROVIDED WITH DEVICES TO ABSORB HIGH PRESSURES RESULTING FROM THE QUICK CLOSING OF THESE VALVES. DRAIN OUT, NO TRAPPING, END OF PIPE LESS THAN 2 FEET ABOVE GROUND, POINTING DOWN. TANKS SHALL BE STRAPPED WITHIN UPPER 1/3 AND LOWER 1/3 TO PREVENT OVERTURNING IN AN EARTHQUAKE. 8 PROVIDE DRYER VENT TO EXTERIOR. PROVIDE RECESSED HOT & COLDSHUTOFF CONTROL VALVES & WASTE AT WASHER. EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 25 FEET. THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 2.5 FEET FOR EACH 45-DEGREE BEND AND 5 FEET FOR EACH 90- DEGREE BEND. A MINIMUM 4-INCH DIAMETER EXHAUST DUCT OF SMOOTHBORE, NONCOMBUSTIBLE MATERIALS REQUIRED WITH BACK-DRAFT DAMPER. 9 ALL DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE. 2. 1. ALL EXTERIOR WALLS ARE 2x6 - 16" O.C. STUDS, UNLESS NOTED OTHERWISE. 3. ALL INTERIOR WALLS ARE 2x4 - 16" O.C. STUDS, UNLESS NOTED OTHERWISE. 4. PROVIDE BACKING IN ALL BATHROOMS FOR TOWEL BARS, TOILET PAPER DISPENSERS, MEDICINE CABINETS, ETC. COORDINATE WITH OWNER FOR LOCATIONS. 5. GENERAL NOTES TEMPERED GLASS16 MECHANICAL FAN. BATHROOM, LAUNDRY ROOMS AND POWDER ROOMS SHALL BE PROVIDED WITH A MECHANICAL FAN CONNECTED TO THE OUTSIDE CAPABLE OF 50 C.F.M. AND SHALL NOT TERMINATE CLOSER THAN 3 FEET TO ANY OPENABLE WINDOW OR OPENING INTO THE BUILDING. MINIMUM DUCT SIZE IS 4 INCHES. DRYER, KITCHEN, AND BATH FANS TO BE SEPERATELY VENTED TO THE OUTSIDE. INSTALL DUCTWORK PRIOR TO INSULATION FOR FRAMING INSPECTION. EXHAUST FANS TO BE CONSTRUCTED OF SMOOTHBORE, NONCOMBUSTIBLE MATERIALS. APPROVED FLEX CONNECTORS NOT EXCEEDING 6 FEET IN LENGTH MAY BE USED IN CONNECTION WITH DOMESTIC DRYER EXHAUST. 10 22" x 30" MIN. ATTIC ACCESS TO BE ACCESSIBLE WITH UNOBSTRUCTED HEADROOM. FRAME OUT ACESS HOLE TO DEPTH OF INSULATION WITH NOT LESS THAN 1/2" PLYWOOD. ACCESS COVER IN GARAGES TO BE HINGED AND SHALL BE WEATHER-STRIPPED OR SEALED TIGHT.11 GUARDRAIL 36" ABOVE FIN. FLR. INTERMEDIATE RAIL SPACING SHALL NOT ALLOW A 4" DIAMETER SPHERE TO PASS THROUGH PER I.R.C. SECTION 312.2.12 PRE-MANUFACTURED, ZERO CLEARANCE GAS FIREPLACE. CONSULT WITH OWNER FOR TRIM PACKAGE. CONTRACTOR SHALL ASSUME ALL OPTIONS. REFER TO MANUFACTURER'S SPECS FOR MINIMUM REQUIREMENTS OF NON-COMBUSTABLE SURROUND & HEARTH MATERIAL.13 STAIR HANDRAIL 36" ABOVE STAIR NOSING. INTERMEDIATE RAIL SPACING SHALL NOT ALLOW A 4" DIAMETER SPHERE TO PASS THROUGH PER I.R.C. SECTION 312.2.14 GARAGE FLOOR SUFACES SHALL BE MIN. 4" CONCRETE. SLOPE CONCRETE FLOOR MIN 1/8" PER 12" TOWARDS MAIN VEHICLE ENTRY DOORWAY OR TOWARDS FLOOR DRAIN.15 17 UP 5'-6" 17'-4 1/2" 5'-10" 53'-6" 24'-0" 10'-4 1/2" 9'-3 1/2" 9'-10" 86'-0" 6'-0"13'-0"31'-0"36'-0" 53'-6" 14'-0" 18'-0" 11'-6" 3'-0" 7'-0" 4'-6" 8'-4 1/2" 9'-3 1/2" 9'-10" 4'-6" 8'-4" 5'-0" 34'-0" 32'-0" 2'-0" 12'-10 1/2" 19'-1 1/2" 86'-0" 14'-0"6'-3 1/2"13'-8 1/2" 14'-7 1/2" 22'-0"34'-0"6'-0" 14'-3 1/2"7'-4 1/2"10'-4"2'-0" SSTB20 HDU2 4 X 12 DF. #2 FLOOR BEAM SIMPSON - HUCQ UPPER FLOOR FRAMING PLAN SCALE: 1/4" = 1'BEARING TO FOOTING 4 X 10 DF. #2 FLOOR BEAM BEARING WALL 4 X 12 DF. #2 FLOOR BEAM BEARING WALL HANGER TO BEAM BEARING WALL 4 X 10 DF. #2 BEARING WALL 3 A7 1 BCI 6000 1.8 "I" JOISTS 16" O.C. A7 1 A7 2 A7 1 A7 4 X 12 DF. #2 FLOOR BEAM 6 X 6 PT POST A10 1 A10 1 A11 4 4 A11 5 A11 5 A11 2 A10 2 A10 3 3 A11 A11 SSTB20 HDU2 4 X 12 DF. #2 FLOOR BEAM 4 X 12 DF. #2 11 7/8" RIM BOARD 5 1/4" X 11 7/8" PSL TO SUPPORT ROOF TRUSSES ABOVE 11 7/8" RIM BOARD 11 7/8" RIM BOARD 11 7/8" RIM BOARD 11 7/8" RIM BOARD SSTB20 HDU2 5/4" POST WRAP 6 X 6 PT POST 5/4" POST WRAP SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 LRP (7/A4)LRP (7/A4) BEARING TO FOOTING NOT TO SCALE NOT TO SCALENOT TO SCALE Nail Boise Rimboard nail into each flange. to BCI joist with 8d NOT TO SCALE 3 JOIST TO BEAM NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE Beam width shall exceed Versa-Lam or Boise GLULAM Beam: Joist hanger Face Mount 2x specified hanger nail length ® Boi s e Ri mboar d Boi s e Ri mb oar d ® into each flange. or rimboard closure. 23/32" min. plywood/OSB Nail with 8d nails required for cantilever. BCI joist blocking® NOT TO SCALE NOT TO SCALENOT TO SCALE Nail Boise Rimboard nail into each flange. to BCI joist with 8d NOT TO SCALE NOT TO SCALE 2 CANTILEVERED JOIST NOT TO SCALE NOT TO SCALE NOT TO SCALE Beam width shall exceed Versa-Lam or Boise GLULAM Beam: Joist hanger Face Mount 2x specified hanger nail length ® Boi se Ri mboar d Boi s e Ri mboar d ® into each flange. or rimboard closure. 23/32" min. plywood/OSB Nail with 8d nails required for cantilever. BCI joist blocking® NOT TO SCALE 1 NOT TO SCALE RIMBOARD NOT TO SCALE Nail Boise Rimboard nail into each flange. to BCI joist with 8d NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE Beam width shall exceed Versa-Lam or Boise GLULAM Beam: Joist hanger Face Mount 2x specified hanger nail length ® Boi se Ri mboar d Boi s e Ri mboar d ® into each flange. or rimboard closure. 23/32" min. plywood/OSB Nail with 8d nails required for cantilever. BCI joist blocking® 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO OF: PAGE: BUILDER INFO: A7 MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout J. SYKORA, CPBD THE WOODS - LOT 7 ANACORTES WA 98221 PHONE: 360-293-7431 WEB: www.strandbergconstruction.com UPPER FLOOR FRAMING PLAN DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLING ALL HEADER MATERIAL TO BE 4 X 10 D.F. # 2 U.N.O. ALL DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE. COORDINATE W/ MECH. & ELEC. FOR LOCATIONS & SIZES OF FOUNDATION/SLAB/ JOISTS BLOCKOUTS. REFER TO SHEET A3 & A4 FOR FOUNDATION NOTES AND DETAILS. 2. 1. FLOOR JOIST OR ROOF TRUSS/RAFTER LAYOUT SHOWN HERE IS FOR SCHEMATIC DESIGN ONLY. MANUFACTURER SHALLPROVIDE AND SUBMIT ENGINEERED DESIGN TO THE BUILDING DEPARTMENT FOR APPROVAL PRIOR TO THE FABRICATIONAND INSTALLATION. 3. ALL TRUSS TO TRUSS & TRUSS TO BEAM CONNECTORS TO BE DESIGNED BY MANUF. 4. FLOOR SHEATHING TO BE 3/4" CDX OR OSB STURDI-FLOOR T&G, GLUE AND NAIL W/ RING SHANK 8d's @ 6" EDGES & 12" IN THEFIELD. FACE GRAIN PERPENDICULAR TO SUPPORTS. ROOF SHEATHING TO BE 7/16" OSB OR EQUAL. 5. PROVIDE SOLID BLOCKING IN THE JOIST CAVITY BENEATH ALL POST LOCATIONS AND BETWEEN UPPER AND LOWER STUDS AT FLOOR TO FLOOR HOLDOWN LOCATIONS. 6. PROVIDE BLOCKING BETWEEN I-JOISTS AT INTERIOR BEARING LOCATIONS WHERE THERE IS A LOAD BEARING WALL ABOVE. 7. 8.ALL CONNECTIONS TO BE SIMPSON OR EQUAL. FRAMING NOTES 2. 1. ALL EXTERIOR WALLS ARE 2x6 - 16" O.C. STUDS, UNLESS NOTED OTHERWISE. 3. ALL INTERIOR WALLS ARE 2x4 - 16" O.C. STUDS, UNLESS NOTED OTHERWISE. 4. PROVIDE BACKING IN ALL BATHROOMS FOR TOWEL BARS, TOILET PAPER DISPENSERS, MEDICINE CABINETS, ETC. COORDINATE WITH OWNER FOR LOCATIONS. 5. GENERAL NOTES 11'-5 3/16" 34'-0" 2'-0"5'-0"27'-0" 32'-0" 17'-4 1/2" 14'-7 1/2" 32'-0" 12'-10 1/2" 9'-3 1/2" 9'-10" 34'-0" 20'-2"13'-10" 24" OVERHANG 24" OVERHANG UPPER ROOF PLAN 24" OVERHANG 24" OVERHANG SCALE: 1/4" = 1' 5/4" X 8" PRIMED FACIA W/ BUILD UP MANUFACTURED TRUSSES 24" O.C. 5/4" X 8" PRIMED FACIA W/ BUILD UP 24" OVERHANG 24" OVERHANG 24" OVERHANG 24" OVERHANG 5/4" X 8" PRIMED FACIA W/ BUILD UP 5/4" X 8" PRIMED FACIA W/ BUILD UP RIDGE VENT 3 A9 7:12 RIDGE BEAM 7:12 RIDGE VENT RIDGE BEAM RIDGE VENT 7:12 7:12 4:12 7:12 7:12 7:12 7:12 2 4 1 A9 A9 1 2 A9 A11 1 A9 GIRDER TRUSS GIRDER TRUSS MATCHES TRUSSES BELOW A9 4 A11 5 A11 2 A9 5 A11 2 A10 2 A10 3 3 A11 A11 W20 3050 SH. W21 2640 SH. W22 2640 SH. W23 2040 SH. W18 3050 SH. W19 3050 SH. 2868 2668 5068 2668 6068 2668 2668 W24 3050 SH. W25 3050 SH. 50 CFM MIN50 CFM MIN 62 sq ft 181 sq ft 190 sq ft 129 sq ft 68 sq ft 49 sq ft 30 sq ft 15 sq ft 26 sq ft 4'-11 1/2" 1'-10 3/4" 2'-11 1/2" 1'-6" 1'-8" 4'-0 1/2" 1'-8" 0'-5" 5'-3 1/2" 3'-7" 2'-0"3'-7 1/2"6'-2 1/2"3'-6"4'-10" 1'-7 1/2" 2'-3 1/2" 2'-6" 0'-3" 2'-6" 2'-3 1/2" 3'-3 3/4" 3'-0" 0'-3" 3'-0" 3'-3 3/4" 3'-7" 2'-0" 3'-8 1/2" 5'-1"3'-0"4'-11" 2'-4" 12'-3 1/2" 5'-0" 32'-0" 34'-0" 32'-0" 34'-0" 14'-0"6'-2" 14'-0"13'-0" 9'-9"4'-6 1/2"5'-10 1/2"2'-0"4'-4 1/2"5'-5 1/2" 12'-8 1/2" 2'-4 1/2" 6'-11" 10'-0" 13'-10"20'-2" 17'-4 1/2" 14'-7 1/2" 27'-0"5'-0"2'-0" 12'-10 1/2" 9'-3 1/2" 9'-10" 4'-4 1/2" 2'-10" 2'-6 1/2" 3'-0" 0'-3" 3'-0" 3'-0" STAIRS LINEN BEDROOM BEDROOM CLOSET OFFICE CLOSET LANDING UPPER FLOOR PLAN SCALE: 1/4" = 1' BATH BATH ATTIC ACCESS CO DET. SMOKE DET. SMOKE DET. 1 1 SMOKE DET. 1 2 2 11 5 5 4 X 8 @ 80" 4 X 8 @ 80" 4 X 8 @ 80" 8' CEILINGS 4 A11 RISER 7 7/16" RUN 10" 4 X 8 @ 80" 4 X 8 @ 80" 4 A11 5 A11 5 A11 10 2 A10 2 A10 3 3 A11 A11 8' CEILINGS 8' CEILINGS 10 PLAN AREAS SCALE: 1/4" = 1' MAIN FLOOR GARAGE 1,633 SQ.FT. 932 SQ.FT. COVERED ENTRY 176 SQ.FT. COVERED PORCHES 153 SQ.FT. UPPER FLOOR 694 SQ.FT. TOTAL LIVING AREA:2,327 SQ.FT.2,327 SQ.FT. 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO OF: PAGE: BUILDER INFO: MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: A8 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout J. SYKORA, CPBD THE WOODS - LOT 7 ANACORTES WA 98221 PHONE: 360-293-7431 WEB: www.strandbergconstruction.com DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLING UPPER FLOOR AND ROOF PLAN 3. 20 MIN. FIRE RATED DOOR. FLOOR PLAN NOTES SMOKE DETECTOR. EVERY DWELLING UNIT SHALL HAVE A SMOKE DETECTOR LOCATED IN EVERY BEDROOM AND AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO EACH SEPARATE SLEEPING AREA. IN NEW CONSTRUCTION, REQUIRED SMOKE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WITH A BATTERY BACKUP. SMOKE DETECTOR AND CO DETECTOR ARE REQUIRED ON EACH LEVEL OF THE STRUCTURE. 1 2 SHELF AND HANGING ROD. BUILT IN SHELVES.3 CABINET - OWNER / CONTRACTOR TO VERIFY.4 EGRESS WINDOWS SHALL HAVE AN OPENABLE SECTION FOR EMERGENCY EGRESS 5.7 SQUARE FEET MIN. MINIMUM NET CLEAR OPENABLE SECTION TO BE 20" WIDE AND 24" HIGH. SILL HEIGHT MAXIMUM 44" OFF FLOOR. 5 WHOLE HOUSE FANS SHALL HAVE A MANUAL CONTROL AND AUTOMATIC CONTROL, SUCH AS A CLOCK TIMER WITH A ZONE RATING OF 1.5 OR LESS.6 F.A.U. ON 18" HIGH PLATFORM. TOP OF PLATFORM TO BE 1 1/8" T & G PLYWOOD. EXPOSED FACE AND SIDES TO HAVE 1 LAYER 5/8" TYPE "X" GYP. BD. NO FURNACE SHALL BE INSTALLED IN ANY CONFINED SPACE WITH ACCESS ONLY THROUGH A BEDROOM, BATHROOM, OR CLOSET. PROVIDE AT LEAST 30" OF WORKING SPACE IN FRONT OF FURNACE.7 ALL BUILDING WATER SUPPLY SYSTEMS IN WHICH QUICK ACTING VALVES ARE INSTALLED, SHALL BE PROVIDED WITH DEVICES TO ABSORB HIGH PRESSURES RESULTING FROM THE QUICK CLOSING OF THESE VALVES. DRAIN OUT, NO TRAPPING, END OF PIPE LESS THAN 2 FEET ABOVE GROUND, POINTING DOWN. TANKS SHALL BE STRAPPED WITHIN UPPER 1/3 AND LOWER 1/3 TO PREVENT OVERTURNING IN AN EARTHQUAKE. 8 PROVIDE DRYER VENT TO EXTERIOR. PROVIDE RECESSED HOT & COLDSHUTOFF CONTROL VALVES & WASTE AT WASHER. EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 25 FEET. THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 2.5 FEET FOR EACH 45-DEGREE BEND AND 5 FEET FOR EACH 90- DEGREE BEND. A MINIMUM 4-INCH DIAMETER EXHAUST DUCT OF SMOOTHBORE, NONCOMBUSTIBLE MATERIALS REQUIRED WITH BACK-DRAFT DAMPER. 9 ALL EXTERIOR WALLS ARE 2x6 - 16" O.C. STUDS, UNLESS NOTED OTHERWISE. 1. 2. ALL DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE. ALL HEADER MATERIAL TO BE 4 X 10 D.F. # 2 U.N.O. 4. PROVIDE BACKING IN ALL BATHROOMS FOR TOWEL BARS, TOILET PAPER DISPENSERS, MEDICINE CABINETS, ETC. COORDINATE WITH OWNER FOR LOCATIONS. ALL INTERIOR WALLS ARE 2x4 - 16" O.C. STUDS, UNLESS NOTED OTHERWISE. 5. GENERAL NOTES TEMPERED GLASS16 MECHANICAL FAN. BATHROOM, LAUNDRY ROOMS AND POWDER ROOMS SHALL BE PROVIDED WITH A MECHANICAL FAN CONNECTED TO THE OUTSIDE CAPABLE OF 50 C.F.M. AND SHALL NOT TERMINATE CLOSER THAN 3 FEET TO ANY OPENABLE WINDOW OR OPENING INTO THE BUILDING. MINIMUM DUCT SIZE IS 4 INCHES. DRYER, KITCHEN, AND BATH FANS TO BE SEPERATELY VENTED TO THE OUTSIDE. INSTALL DUCTWORK PRIOR TO INSULATION FOR FRAMING INSPECTION. EXHAUST FANS TO BE CONSTRUCTED OF SMOOTHBORE, NONCOMBUSTIBLE MATERIALS. APPROVED FLEX CONNECTORS NOT EXCEEDING 6 FEET IN LENGTH MAY BE USED IN CONNECTION WITH DOMESTIC DRYER EXHAUST. 10 22" x 30" MIN. ATTIC ACCESS TO BE ACCESSIBLE WITH UNOBSTRUCTED HEADROOM. FRAME OUT ACESS HOLE TO DEPTH OF INSULATION WITH NOT LESS THAN 1/2" PLYWOOD. ACCESS COVER IN GARAGES TO BE HINGED AND SHALL BE WEATHER-STRIPPED OR SEALED TIGHT.11 GUARDRAIL 36" ABOVE FIN. FLR. INTERMEDIATE RAIL SPACING SHALL NOT ALLOW A 4" DIAMETER SPHERE TO PASS THROUGH PER I.R.C. SECTION 312.2.12 PRE-MANUFACTURED, ZERO CLEARANCE GAS FIREPLACE. CONSULT WITH OWNER FOR TRIM PACKAGE. CONTRACTOR SHALL ASSUME ALL OPTIONS. REFER TO MANUFACTURER'S SPECS FOR MINIMUM REQUIREMENTS OF NON-COMBUSTABLE SURROUND & HEARTH MATERIAL.13 STAIR HANDRAIL 36" ABOVE STAIR NOSING. INTERMEDIATE RAIL SPACING SHALL NOT ALLOW A 4" DIAMETER SPHERE TO PASS THROUGH PER I.R.C. SECTION 312.2. 14 GARAGE FLOOR SUFACES SHALL BE MIN. 4" CONCRETE. SLOPE CONCRETE FLOOR MIN 1/8" PER 12" TOWARDS MAIN VEHICLE ENTRY DOORWAY OR TOWARDS FLOOR DRAIN. 15 17 2'-0"OPEN SOFFIT 1/2" SHEETROCK 1 TYPICAL EAVE DETAIL SCALE: 1/2" = 1' 5/8" SHEETROCK R-49 INSULATION MANUFACTURED TRUSSES 24" O.C. COMPOSITION ROOFING 7/16" OSB 5/4 X 8 PRIMED FACIA ALUM. DRIP EDGE AIR BAFFLE W/ 1" GAP GUTTER SIMPSON SDWC 7 12 2'-0" 1/2" SHEETROCK 5/8" SHEETROCK 7/16" OSB 2 EAVE DETAIL @ GABLE W/ STEPPED FACIA SCALE: 1/2" = 1' R-49 INSULATION MANUFACTURED TRUSSES 24" O.C. ROOFING MATERIAL ROOFING FELT 5/4 X 8 PRIMED FACIA ALUM. DRIP EDGE 5/4 X 4 PRIMED FACIA 3 HURRICANE CONNECTION DETAIL NOT TO SCALE 5'-6" 17'-4 1/2" 2'-6" 32'-0" 86'-0" 24'-0"18'-6"5'-6"32'-0"6'-0" 53'-6" 7'-0" 3'-0" 11'-6" 18'-0" 14'-0" 86'-0" 36'-0"31'-0"19'-0" 53'-6" 24'-0" 29'-6" 2'-0"5'-0"2'-0"22'-0" 5/4" X 8" PRIMED FACIA W/ BUILD UP BEARING WALL BEARING WALL BEARING WALL ROOF FRAMING PLAN BEARING WALL MANUFACTURED TRUSSES 24" O.C. 3:12 SCALE: 1/4" = 1' SIMPSON HANGERS MANUFACTURED TRUSSES 24" O.C. 2 MATCHES TRUSSES ABOVE 16" HEEL 16" HEEL 16" HEEL ROOF BEAM @ 109 1/8" 4 X 10 DF. #2 ROOF BEAM @ 109 1/8" 4 X 10 DF. #2 ROOF BEAM @ 109 1/8" 6 x 6 TREATED POST 24" OVERHANG 4 X 10 DF. #2 ROOF BEAM @ 109 1/8" 6 x 6 TREATED POST 6 x 6 TREATED POST 6 x 6 TREATED POST 6 x 6 TREATED POST MANUFACTURED TRUSSES 24" O.C. MANUFACTURED TRUSSES 24" O.C. 24" OVERHANG 24" OVERHANG 24" OVERHANG 24" OVERHANG 24" OVERHANG 24" OVERHANG 24" OVERHANG 4 X 10 DF. #2 ROOF BEAM @ 109 1/8"7:12 7:12 7:12 7:12 7:12 7:12 RIDGE BEAM RIDGE VENT 7:12 7:12 3:12 3:12 3:12 RIDGE VENT RIDGE BEAM RIDGE BEAM RIDGE VENT GIRDER TRUSS 5/4" X 8" PRIMED FACIA W/ BUILD UP 5/4" X 8" PRIMED FACIA W/ BUILD UP 5/4" X 8" PRIMED FACIA W/ BUILD UP A10 RIDGE VENT A9 1 A9 1 A9 1 SIMPSON HANGERS A9 GIRDER TRUSS SIM. 1 MANUFACTURED TRUSSES 24" O.C. A10 1 A11 4 4 A11 5 2 A9 A9 A11 2 A9 2 5 A11 2 A10 SIMPSON HANGERS 2 A10 3 3 A11 A11 RIDGE VENT RIDGE VENT 4 X 10 DF. #2 ROOF BEAM @ 109 1/8" 4 X 10 DF. #2 ROOF BEAM @ 109 1/8" 4 X 10 DF. #2 ROOF BEAM @ 109 1/8" MANUFACTURED TRUSSES 24" O.C. SITE FRAME MANUFACTURED TRUSSES 24" O.C. 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO OF: PAGE: BUILDER INFO: MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout A9 J. SYKORA, CPBD THE WOODS - LOT 7 ANACORTES WA 98221 PHONE: 360-293-7431 WEB: www.strandbergconstruction.com DESIGNED BY: SCALE LOWER ROOF FRAMING PLAN DATE DRAFTED BY: J. STERLING 3. COORDINATE W/ MECH. & ELEC. FOR LOCATIONS & SIZES OF FOUNDATION/SLAB/ JOISTS BLOCKOUTS. REFER TO SHEET A3 & A4 FOR FOUNDATION NOTES AND DETAILS. 2. 1. FLOOR JOIST OR ROOF TRUSS/RAFTER LAYOUT SHOWN HERE IS FOR SCHEMATIC DESIGN ONLY. MANUFACTURER SHALLPROVIDE AND SUBMIT ENGINEERED DESIGN TO THE BUILDING DEPARTMENT FOR APPROVAL PRIOR TO THE FABRICATIONAND INSTALLATION. 3. ALL TRUSS TO TRUSS & TRUSS TO BEAM CONNECTORS TO BE DESIGNED BY MANUF. 4. FLOOR SHEATHING TO BE 3/4" CDX OR OSB STURDI-FLOOR T&G, GLUE AND NAIL W/ RING SHANK 8d's @ 6" EDGES & 12" IN THEFIELD. FACE GRAIN PERPENDICULAR TO SUPPORTS. ROOF SHEATHING TO BE 7/16" OSB OR EQUAL. 5. PROVIDE SOLID BLOCKING IN THE JOIST CAVITY BENEATH ALL POST LOCATIONS AND BETWEEN UPPER AND LOWER STUDS AT FLOOR TO FLOOR HOLDOWN LOCATIONS. 6. PROVIDE BLOCKING BETWEEN I-JOISTS AT INTERIOR BEARING LOCATIONS WHERE THERE IS A LOAD BEARING WALL ABOVE. 7. 8.ALL CONNECTIONS TO BE SIMPSON OR EQUAL. FRAMING NOTES ALL EXTERIOR WALLS ARE 2x6 - 16" O.C. STUDS, UNLESS NOTED OTHERWISE. 1. 2. ALL DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE. ALL HEADER MATERIAL TO BE 4 X 10 D.F. # 2 U.N.O. 4. PROVIDE BACKING IN ALL BATHROOMS FOR TOWEL BARS, TOILET PAPER DISPENSERS, MEDICINE CABINETS, ETC. COORDINATE WITH OWNER FOR LOCATIONS. ALL INTERIOR WALLS ARE 2x4 - 16" O.C. STUDS, UNLESS NOTED OTHERWISE. 5. GENERAL NOTES R-21 INSULATION T&G PINE 6 X 10 D.F. #2 @ 109 1/8" WRAP BEAM W/ 5/4" PRE-PRIMED SPRUCE WRAP BEAM WITH HARDI MATERIAL T&G PINE 6 X 10 D.F. #2 @ 109 1/8" GUTTER 5/4 X 8" FASCIA OPEN SOFFIT COMPACTED FILLCRAWLSPACE 12 5/8" FLOOR SYSTEM R-30 INSULATION SIMPSON HANGER 4" CONCRETE SLAB MANUFACTURED TRUSSES 24" O.C. 2 X 6 WALL 5/8" SHEETROCK 1/2" SHEETROCK MANUFACTURED TRUSSES 24" O.C. R-49 INSULATION 7 12 RIDGE VENT 7 12 RIDGE VENT RIDGE VENT 5/4" X 4" PRIMED FACIA BUILD UP 5/4" X 8" PRIMED FACIA SIDING 7/16" SHEATHING COMPOSITION ROOFING COMPOSITION ROOFING SIMPSON HANGER SIMPSON HANGER 2 X 6 PONY WALL 2 X 6 PONY WALL 5/4" X 4 PRIMED CORNER TRIM DINING KITCHEN LAUNDRY GARAGE 16" HEELSIMPSON HANGER OPEN SOFFIT5/4 X 8 PRIMED FACIA GUTTER 1 BUILDING SECTION SCALE: 1/4" = 1' 25'-6" 9'-1 1/8" 8'-1 1/8" 8'-1 1/8" 9'-1 1/8" CRAWLSPACE 12 5/8" FLOOR SYSTEM R-30 INSULATION SIMPSON HANGERSIMPSON HANGER BEDROOM MAIN FLOOR SIMPSON HANGER 5/4" X 4" PRIMED FACIA BUILD UP 5/4" X 8" PRIMED FACIA RIDGE VENT RIDGE VENT COMPOSITION ROOFING COMPOSITION ROOFING 7 12 OVERALL BUILDING HT. 12 5/8" FLOOR SYSTEM 4" CONCRETE SLAB LIVING T&G PINESIMPSON HANGER MANUFACTURED TRUSSES 24" O.C. MANUFACTURED TRUSSES 24" O.C. GUTTER 5/4 X 8" FACIA OPEN SOFFIT WRAP BEAM WITH HARDI MATERIAL BUILT OUT COLUMN BEAMS @ 109 1/8" 1/2" SHEETROCK 5/8" SHEETROCK R-21 INSULATION R-49 INSULATION R-49 INSULATION R-30 INSULATION 2 X 6 PONY WALL 2 X 6 PONY WALL 2 BUILDING SECTION SCALE: 1/4" = 1' 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO OF: PAGE: BUILDER INFO: MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout J. SYKORA, CPBD THE WOODS - LOT 7 A10 ANACORTES WA 98221 PHONE: 360-293-7431 WEB: www.strandbergconstruction.com DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLING BUILDING SECTIONS 8'-1 1/8" 9'-1 1/8" 25'-6" 8'-1 1/8" 9'-1 1/8" 5/4 X 8" FACIA ROOF BEAM @ 109 1/8" WRAP BEAM W/ 5/4" PRE-PRIMED SPRUCE BUILT OUT COLUMN OPEN SOFFIT GUTTER CULTURED STONE 4" CONCRETE SLAB COMPOSITION ROOFING RIDGE VENT 7 12 SHINGLE SIDING 6" EXPOSURE SHINGLE SIDING 6" EXPOSURE 5/4" X 4" PRIMED FACIA BUILD UP RIDGE VENT 5/4" X 8" PRIMED FACIA HARDI-PLANK SIDING 7" EXPOSURE HARDI-PLANK SIDING 7" EXPOSURE 4" CONCRETE SLAB MAIN FLOOR OVERALL BUILDING HT. T&G PINE COMPACTED FILL 2 X 6 PONY WALL R-30 INSULATION 2 X 6 PONY WALL CRAWLSPACE 12 5/8" FLOOR SYSTEMSIMPSON HANGER SIMPSON HANGER 12 5/8" FLOOR SYSTEM OFFICE FLOOR BEAM RIDGE VENT COMPOSITION ROOFING COMPOSITION ROOFING MANUFACTURED TRUSSES 24" O.C. SIMPSON HANGER SHINGLE SIDING 6" EXPOSURE 1/2" SHEETROCK 5/8" SHEETROCK R-21 INSULATION BEDROOM MASTER BEDROOM 5/4 X 8" FACIA OPEN SOFFIT R-49 INSULATION MASTER BATH 1/2" SHEETROCK 5/8" SHEETROCK R-21 INSULATION 9'-1 1/8" 8'-1 1/8" 9'-1 1/8" 8'-1 1/8" MANUFACTURED TRUSSES 24" O.C. MANUFACTURED TRUSSES 24" O.C. MAIN FLOOR 12 5/8" FLOOR SYSTEM R-30 INSULATION 4 BUILDING SECTION SCALE: 1/4" = 1' 18" X 18" X 18" CONCRETE FOOTING R-30 INSULATION 1/2" SHEETROCK 5/8" SHEETROCK R-21 INSULATION R-49 INSULATION RIDGE VENT COMPOSITION ROOFING R-49 INSULATION 5/4" X 4" PRIMED FACIA BUILD UP 5/4" X 8" PRIMED FACIA RIDGE VENT CRAWLSPACE 12 5/8" FLOOR SYSTEM 12 5/8" FLOOR SYSTEM COMPACTED FILL 2 X 6 PONY WALL 4 X 4 POST GUTTER OPEN SOFFIT 5/4 X 8" FASCIA 2 X 6 PONY WALL OFFICE KITCHEN BATHCABINET T.B.D. 9'-1 1/8" 8'-1 1/8" 9'-1 1/8" 8'-1 1/8" 12 5/8" FLOOR SYSTEM CRAWLSPACE CABINET T.B.D.CABINET T.B.D. MAIN FLOOR 12 5/8" FLOOR SYSTEM MANUFACTURED TRUSSES 24" O.C. RIDGE VENT 5 BUILDING SECTION SCALE: 1/4" = 1' 7 12 5/4" X 4" PRIMED FACIA BUILD UP 5/4" X 8" PRIMED FACIA 1/2" SHEETROCK 5/8" SHEETROCK R-21 INSULATION MANUFACTURED TRUSSES 24" O.C. R-49 INSULATION R-49 INSULATION GUTTER OPEN SOFFIT 5/4 X 8" FASCIA 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO OF: PAGE: BUILDER INFO: MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout J. SYKORA, CPBD THE WOODS - LOT 7 ANACORTES WA 98221 PHONE: 360-293-7431 WEB: www.strandbergconstruction.com DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLING A11 2'-0" 8'-1 1/8" 9'-1 1/8" 25'-6" 3'-7 3/16" MAIN FLOOR OVERALL BUILDING HT. OPEN SOFFIT COMPOSITION ROOFING 6" EXPOSURE 5/4" X 8" PRIMED FACIA SHINGLE SIDING 4" CONCRETE SLAB COMPOSITION ROOFING SHINGLE SIDING 6" EXPOSURE RIDGE VENT 6" EXPOSURE COMPOSITION ROOFING RIDGE VENT 5/4" X 4" PRIMED FACIA BUILD UP RIDGE VENT HARDI-PLANK SIDING 7" EXPOSURE SHINGLE SIDING HARDI-PLANK SIDING 7" EXPOSURE 12 7 12 3 3 12 HARDI-PLANK SIDING 7" EXPOSURE HARDI-PLANK SIDING 7" EXPOSURE COMPOSITION ROOFING 4 12 12 7 12 5/8" FLOOR SYSTEM 5/4" X 4 PRIMED CORNER TRIM 5/4" X 4 PRIMED CORNER TRIM 5/4" X 8" PRIMED FACIA 5/4" X 8" PRIMED FACIA 5/4" X 4" PRIMED FACIA BUILD UP OPEN SOFFIT 5/4 X 8 PRIMED FACIA GUTTER5/4" X 4" PRIMED FACIA BUILD UP 5/4 X 8 PRIMED FACIA GUTTER5/4" X 4" PRIMED FACIA BUILD UP OPEN SOFFIT 5/4 X 8 PRIMED FACIA GUTTER OPEN SOFFIT 5/4 X 8 PRIMED FACIA GUTTER 4" CONCRETE SLAB CULTURED STONE 5/4 WRAPPED BEAM 5/4 WRAPPED POST 5/4 WRAPPED BEAM W10 2660 SH. W17 2650 SH. W19 3050 SH. NORTH ELEVATION SCALE: 1/4" = 1' 25'-6" 9'-1 1/8" 8'-1 1/8" 2'-0" 2'-0" 2'-0" 5/4" X 8" PRIMED FACIA RIDGE VENT 5/4" X 4" PRIMED FACIA BUILD UP SHINGLE SIDING 6" EXPOSURE COMPOSITION ROOFING COMPOSITION ROOFING COMPOSITION ROOFING 3 12 7 12 CULTURED STONE RIDGE VENT RIDGE VENT HARDI-PLANK SIDING 7" EXPOSURE 12 5/8" FLOOR SYSTEM CULTURED STONE CULTURED STONE OPEN SOFFIT 5/4 X 8 PRIMED FACIA GUTTER OPEN SOFFIT 5/4 X 8 PRIMED FACIA GUTTER OPEN SOFFIT 5/4 X 8 PRIMED FACIA GUTTER 5/4 WRAPPED BEAM 5/4" X 4" PRIMED FACIA BUILD UP W13 2650 SH. W14 1660 SH.W15 1660 SH. W16 2650 SH. W20 2640 SH.W21 2640 SH.W22 2040 SH. WEST ELEVATION SCALE: 1/4" = 1' W23 3050 SH.W24 3050 SH. HARDI-PLANK SIDING 7" EXPOSURE OVERALL BUILDING HT. 5/4" X 4 PRIMED CORNER TRIM MAIN FLOOR 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO OF: PAGE: BUILDER INFO: MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout J. SYKORA, CPBD THE WOODS - LOT 7 A12 ANACORTES WA 98221 PHONE: 360-293-7431 WEB: www.strandbergconstruction.com DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLING EXTERIOR ELEVATIONS 8'-1 1/8" 25'-6" 9'-1 1/8" 12 7 5/4" X 8" PRIMED FACIA RIDGE VENT 5/4" X 4" PRIMED FACIA BUILD UP 7 12 12 3 HARDI-PLANK SIDING 7" EXPOSURE HARDI-PLANK SIDING 7" EXPOSURE HARDI-PLANK SIDING 7" EXPOSURE COMPOSITION ROOFING W6 6080 PATIO DOORW11 6080 PATIO DOOR OPEN SOFFIT RIDGE VENT RIDGE VENT 5/4" X 4 PRIMED CORNER TRIM RIDGE VENT RIDGE VENT 5/4 X 8 PRIMED FACIA GUTTER 5/4" X 4" PRIMED FACIA BUILD UP OPEN SOFFIT5/4 X 8 PRIMED FACIA GUTTER OPEN SOFFIT5/4 X 8 PRIMED FACIA GUTTER 5/4 WRAPPED BEAM 5/4 WRAPPED POST 5/4 WRAPPED POST 5/4 X 8 PRIMED FACIA 5/4" X 4" PRIMED FACIA BUILD UP EAST ELEVATION SCALE: 1/4" = 1' W5 3050 SH. W8 3016 PIC.W9 3016 PIC. W12 3050 SH. W17 3050 SH.W18 3050 SH. 12 5/8" FLOOR SYSTEM MAIN FLOOR OVERALL BUILDING HT. 8'-1 1/8" 25'-6" 9'-1 1/8" COMPOSITION ROOFING COMPOSITION ROOFING COMPOSITION ROOFING COMPOSITION ROOFING HARDI-PLANK SIDING 7" EXPOSURE HARDI-PLANK SIDING 7" EXPOSURE HARDI-PLANK SIDING 7" EXPOSURE 6" EXPOSURE SHINGLE SIDING 12 7 12 7 12 7 5/4" X 8" PRIMED FACIA RIDGE VENT 5/4" X 4" PRIMED FACIA BUILD UP RIDGE VENT RIDGE VENT RIDGE VENT 12 5/8" FLOOR SYSTEM 5/4" X 4 PRIMED CORNER TRIM PRIMED TRIM OPEN SOFFIT MAIN FLOOR W1 2650 SH. W2 3050 SH.W3 3050 SH.W4 3050 SH. W7 2660 SH. OVERALL BUILDING HT. 5/4" X 4 PRIMED CORNER TRIM SOUTH ELEVATION SCALE: 1/4" = 1' 5/4 X 8 PRIMED FACIA GUTTER 5/4" X 4" PRIMED FACIA BUILD UP OPEN SOFFIT 5/4 X 8 PRIMED FACIAGUTTER OPEN SOFFIT 5/4 X 8 PRIMED FACIAGUTTER OPEN SOFFIT 5/4 X 8 PRIMED FACIA GUTTER 5/4" X 4" PRIMED FACIA BUILD UP 5/4 WRAPPED BEAM 5/4 WRAPPED POST 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO EXTERIOR ELEVATIONS OF: PAGE: BUILDER INFO: MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout J. SYKORA, CPBD THE WOODS - LOT 7 A13 ANACORTES WA 98221 PHONE: 360-293-7431 WEB: www.strandbergconstruction.com DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLING SSTB20 HDU2 BEARING WALL BEARING WALL BEARING WALL BEARING WALL SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 SSTB20 HDU2 LRP (7/A4)LRP (7/A4) SW5 SW5 SW4 SW4 SW4 SW0 SW4 NOTE: SW5 - 5/8" CD PLY REQUIRED ON EXTERIOR SIDE ONLY 1100--0066--1155 THE INFORMATION, PLANS, DESIGNS, NOTES AND ARRANGEMENTS SHOWN ON THIS DRAWING ARE CONFIDENTIAL AND MAY NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF STRANDBERG CONSTRUCTION INC. DRAWINGS NOTED AS PRELIMINARY, SCHEMATIC, AND/ OR CONCEPT CONTAIN INFORMATION THAT IS CONCEPTUAL AND SUBJECT TO CHANGE. THE DESIGNER MAKES NO CLAIM FOR ACCURACY OF CONCEPTUAL INFORMATION OR OF INFORMATION SUPPLIED BY OTHERS. INITIAL: OWNER APPROVAL PROJECT / CLIENT INFO OF: PAGE: BUILDER INFO: MAILING ADDRESS: P.O. BOX 319 Tuesday, October 06, 2015 PRINTED: 1/4" = 1' U.N.O. FILE: S:\Strandberg Companies\SCINC\DESIGN JOBS\The Woods\Lot 7\Lot 7 - The Woods 24x36 Layout.layout J. SYKORA, CPBD THE WOODS - LOT 7 ANACORTES WA 98221 A14 PHONE: 360-293-7431 WEB: www.strandbergconstruction.com DESIGNED BY: SCALE DATE DRAFTED BY: J. STERLING ENGINEERING INFO