Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File BLD-2020-0067 3011 Oakes Avenue (2)
--.-- - illIPPrar _ _ - ' 'r ' SCOPE OF WORK .- - _ _ .�- .: . � 6" PROPOSED NEW 6 . 21 KW ( DC) ROOF MOUNTED _ /►� PHOTOVOLTAIC ( PV) SYSTEM WITH FOLLOWING # r ` ' `" V < C • o° ails sfeer- ae V121x62 • EQUIPMENT: .; .11#111.111Pill lilt arm- - . .. AH APP��c)��AL. ( 17 ) HYUNDAI HIA-S365H1 SOLAR MODULE r • ‘__ , .. . %.. ,, _._ fl1ncwr . - . fl V/ , c. ( 1 ) SOLAREDGE SE6000H-US INVERTER ' FEB "^ 1' D 2 6 2020 UNIRAC SOLARMOUNT FLUSH RACKING SYSTEM _ g �` g � � i �` f . a q-. + .+tw ,` . NW .A _ A. t I 1( . CAPSTRNE SITE DETAIL - '' `` • SOLUTIONSNrI ELECTRIC UTILITY PROVIDER: PUGET SOUND ENERGY DESCRIPTION DATE REVISION ELECTRIC SERVICE RATING : 1 25A �N.. INITIAL 1/ 1 G/ZO ".4 t ''t\ ROOF MATERIAL: COMPOSITE SHINGLE 'cl �'' �` • ASCE 7 GROUND SNOW LOAD: 25 PSF 3. ` ASCE 7- 10 WINSPEEDS ( 3 SEC GUST IN MPH ) k -RISK CATEGORY I : 100 CC.; . Solar Developer -RISK CATEGORY II : 1 10 CHRISTOPHER CANAVAN -RISK CATEGORY III-IV: 1 15 RICH PHILLIPS ASCE 7-05 WINDSPEED: 85 ( 3-SEC PEAK GUST IN MPH ) ASCE 7-93 WINDSPEED: 71 ( FASTEST MILE IN MPH ) System Engineer Irk ERIC WILSON TIM WACHTMAN I 4 li • ,p-.,� Customer Info - CAROL LEE & DOUG ALLEN 30 I I OAKES AVE ANACORTES PtiorovoLfefic NOT- � CODE AUTHORITY: WA 98221 20. ALL WIPING' CONCEALED I!J WALL ��JD GE 5P �5 SI��LL oe !N MET-AL CONDUIT, PARCEL#: P58403 21. TH5 SEISMIC PPACTING AND ANCHORAGE OF CLECTPIGAL CONDUITS 51IALL ICE IN AGGOPDAot V/Irnn THE 1. AIJ INVERTEP OP AN AG MODULE IN AN /NT-EDICT Nf PHUT r1/OLT A/G _SYSTEM SHALL AUi OMAr/G ALL DE-E,VC SIZr 115 'StI Gl JA"-GUIDUNCS POI' St151110- PrSTI'A/HH S OP MtGHAI•UGAL SYSTEMS AND PLUMING PIPING SY5rr115. Project Details ourrur To 511E CONNECTED ELECTRICAL Peoa rcrlol J AND D15TPIPUT-ION l JCR/0PK UPON Lo 55 OF VOLTAGE 111 THAT 22. ALL OF THE uSrtD S7-E,'15 KEDUIKKD THAT THE SEISMIC LArreAL FORCE P INCLUDING GONSIDEPATIOI.I OF o^P AND 2015 WAS H I N G TO N STATE BUILDING CODE ( 2 015 IBC) SYSTEM AND 5HALL P511AW IN rr1Ar STATE uvHL Tree ELECTRICAL PRODUCTION AND DIS1 IDUTION NETWOj',C VOLTAGE it P PE DETEPPIINtD Ar PAGli LEVEL- OF rND PU/LDING 50 r17Ar C%l'AGP -PAGING cm of GALcJLATCD. T1it DISTRICT 2015 WAS H I N GTO N STATE ENERGY CODE ( 2 015 I E CC) 6 .2 I KW HAS PEEN RESTORED, CNEG 690361) SnnUGrURAL t1\ INCEP CAN APPPOI 'E nit 5t15`11G LATERAL FOPCC DETERMINATION. ROOFTOP PV 2. ALL EXTEPIOK ELECTRICAL METALLIC TUPING(SMr) CONDUIT- FIrTINr St1 ALL PE PAIN TIGHT THREAD-LE55 25. A C-OPV OFTHE (.7H05EN PPACING SYSTEM(-) INSTALLATION GUIDE/MANUAL- SHALL ✓E 01,17-nt JOP SITE PP10P ro 2015 WAS H I N GTO N STATE RESIDENTIAL CODE ( 2015 SYSTEM GOMPPESSIONnPE. STAFT INS nit INSTALLING OFI1ANGCPSAND/OP °PACES. INTERNATIONAL RESIDENTIAL CODE WASHINGTON 5. 110DULE5 AND SUPPORT STPUGTUPE5 SHALL- PE &POUNDED 24,WHEI 111157-ALLINS DRILLED-IN AIJCHOPS AND/OP POWDER DPI.; EN PINS IN EXISTING NOI l-PPE5rPCSSED TILT 4, NAMEPLATES SHALL DE FPO/ IDED FOP ALL CIRCUITS IN THE SEPV IOC D15TPIPUTION AND POWER' DISTP/PiUTIOJ RE/NFOKGED coNcetrt, USE GAPE AND CAUTION�r TO AVOID GUTTING oe DAMAGING THE PCIVFOKGCD PAPS . WHEN AMENDMENTS 2014 WA C 51 -51 -2 3 0 0 SECTION M 2 3 0 2 ) 514 w-otl POAPP S, PANEL POAPDS, DISCONNECTING SV: 1rct1cS, TEPi lINAL CAPIVETS, ETC. ALL NAMEPLATES SHALL DE INSTALLING THEM INTO EXISTING PPE-5TPESSED CONCRETE TENDONS DY USING A NON-DtSTPUGTI✓C METHOD PPIOP PERMANENTLY ATTACHED AND DC OF SUFFICIENT- CAPACITY rC WITHSTAND THE WEATTIEP. TO INSTALLATION. EXERCISE EX,TPEME GAPE AND GAL1TION TO AVOID TATTING OP DAMAGING THE TENDONS DUPING- 2017 WAC 29 6-4 6 B ( 2 017 NEC) 14. 5° 5, JUNCTION 00X/c ,011PINEK PDX HAVE TO USE C,071PPCS510N TYPO 57-PAIN RELIEF POSITIONED FOP APPPOPPIATE INSTALLATION. MAD I rA1N A MINIMUM CLEARANCE OF ONE INCH DSTbVEEN THE PEINFOPGEME1•IT AND THEE PILLED-Iv ANGHOP, 2015 WAS H I N G TO N STATE MECHANICAL CODE ( 2 015 U M C ) AZIMUTH V/ATEP PUN OFF. 25, rtcWOKKINS GLEAKANGES AROUND THE EXISTING ELEGTP. IGAL EQUIPMENT ASV/ELL AS THE NEW ELEGTPICAL 6. CONDUIT PUNS SHALL PE PROVIDED V/1111 SurriclENrWEATHEPPPOOP PULL FOXES OF .,UNCTION 00X/G0110/NCR EOUIPMEl 17- WILL PE MAINTAINED !N AGGOPP/INGE WITH NEC 110.26. 2015 WAS H I N GTO N STATE PLUMBING CODE ( 2 015 UPC) 160° PDXES PEP APPPOPPIATE NEG REOUIPENENT S• 26, CONDUCTORS EXPOSED TO SUNU6177- SHALL DE LISTED AS SUNLIGHT PE SI STANT (NEC 500.6 01, 510.8 D) Z 015 WAS H I N G TO N STATE FIRE CODE ( Z 01 I FC) 7. 5EE PPO�/IDLD cur SHEETS FOP ADDITIONAL earn SrecIr/CATIONS 27. &POUNDING DUSHINSS APE PEQUIKEP AROUND PPE-PUNCHED CCNCEN7KIG KNOG,rour5 ON THE DC SIDE OF riff SOLAR MODULE 8, WI?1NG MATERIALS SHALL ICE SUIrAPLC POP THE SUN EXPOSURE AND IVCT LOCATIONS. FIELD APPLIED PKOTECTA/E SYSTEM, (NEC 250.97) COATINGS APE NOT ACCCPIAPLE, 28•1715 GROUNDING ELECTRODE CONDUCTOR MUST DE PKoreGTED PROM PH,'S1GAL DAMAGE 1F SMALLER THAN #6 1 AVeI HYUNDA9Jo IC7ION, PULL Al ID OUTLETPDXES LOCATED DEMI :ID MODULES SH 5 ALL GE 0 INSTALLED THAT nit WIPING COPPER WIPE MC 250.64 P) 3 0 { ogke5 H iA-S3 6 5 H 1 f THEM 1 PENDCP, tD AGGESSIPLE DIRECTLY OP DY DISPLACEMENT OF NOP-ULECS) SECURED 3Y 29. GROUNDING ELECTRODE CONDUCTOR, WILL PE CONTINUOUS: EXCEPT POP SPLICES OP JOINTS AT PL1504 ?5 WITHIN GOIJTAI!\ ED IN r E GA J t . PENOVAPLE FASTEI.15PS AND CONNECTED Pi' 4 FLEX IDLE WIPING C'STEN. (NEC 69034) LISTED EQUIPMENT. Cl-:ISG 250,64 C) - ET INDEX: INVERTER 10• /k AN UVDEKGPOUND P110m, OLTAIG SYSTEM, 7-H5 PUNIER SOURCE SHALL. DC LAPEL-CD W17-11 THE FOLLOWIIJS 50• RACEWAY roe &POUNDING ELEG7PCDC CONDUCT-OP SHALL PE PONPED Ar EACH END. CCEG 250.64 CC) WARN/NG AT EACH JUNCTION PDX, GOMD/NEP PDX, D/XONNEGT AND DEV1Gt WHERE THE' UNGROUNDED G/POJITS MAY PE 51. WHERE ALL TERMINALS or 511E DISCONNECTING r 1EM15 MAY PE ENEPGIZ_ED I I THE OPEN POSITION, A SIGN WILL Of A- 1 : NOTES, INDEX, SITE INFO, PROJECT DATA, CODE SOLAREDGE SE6000H-US EXPOSED DUPING SEPI/ICE : " WAPNIIIS - El FCTP/G SHOCK tIAZAI?P, THE CUPPCNT CIRCUIT GONDUGTOPS OF MI5 PROVIDED W APNIN& OF THE 1IA7_An D PEP REG 690,11. 54. EACH UNGROUNDED CONDUCTOR OF THE NULT-RVIPE vPA1JGll A-2 : SITE PLAN PHOTOVOLTAIC ROVER SYSTEM APE UNGPCUIJDED PUT- MAY Pr ENERGIZED WITH THE RESPEcr 7-0 GROUND DUE TO G/PGUTT WILL DE 10E1 gra PEP PHASE Al ID SY SrEM PEP NEC210.5. ESTIMATED ANNUAL PRODUCTION LEAKAGE PATHS AND/OP GROUND FAULTS" (Nrot 690. (P)) 32 ClRGUIrs OVER 250V TO GROUND SHALL COMPLY WITH NCG250.97 8 250.92 CP) 1 LA,NG 95250.97. A-3 : PV LAYOUT AND COMPONENT LOCATION 11, ALL Ptloror /oLrAIG MODULES ARID ASSOCIATED EQUIPMENT 4ND WIPING MATERIAL SHALL PE PPOTCGTCP FP011 AM' 33, PC GO/ IDUGTOKS mute DO Nor CIJTCR THE DUILDIIJG OP APE PUN IN METALUG KAGCW AYS OP El IGLOSUPr5 r0 THE E- 1 : ELECTRICAL LINE DIAGRAM 6578 kWh/Yr PHYSICAL DAMAGE. FIRST AGCt55IOLt DG DISCONNECTING MEANS PEP NJEG 690._'i1 (E), LANG 95.67051 (C) 12. ALL ELECTRICAL DEVICES AND UTILIZATION EOUIPMEI T SrIALL PC USrtn DY AN APPROVED TESTING AGENCY, 54. ALL MEIN-LIG FRAME PAILS AND OTHEP CUPPENT GAMIN& METALLIC. COMPONENTS (COIJDUIT, uUNGreoN et PULL E-2 : LABELING INFORMATION Drawing 15. otrDOOK toU/PMENT SI TALL PE Ar LEAST 115114 5P RATED. PDXES, RACEWAY, ETC) SHALL GE SOLIDLY &ROUNDED PEP THE MAINUPAGrUPrP'S INST-ALLATION /AI STPUCT/0115 LAME E-3 : EQUIPMENT: P V MODULE SPECIFICATION SHEET /4. ALL SPECIFIED WIRING 15 PASEO ON THE U5E OF COPPER 95.690.110 ff 95.110502 NOTES, 15. careAGToe SHALL ODTAINtLEG -PIGALPSPMIr5AND SHALL. GvoPDINATEALL INSPECTION, COMMISSIONING AME) r, SGKCWS, NUr5: 60Lr5et+ASHER'SrHATATTAGHEDUIPMEIIrGPOUNDING LUGS 5HALLPiE STAINLESS STEEL- LANG E-4: EQUIPMENT: INVERTER SPECIFICATION SHEET INDEX, SITE INFO, PROJECT DATA, AGGterAIJCt Wild rl/E CLIENT. UTILITY co AND CITY INSPECT-0PS AS NEEDED 95.1/03(0). I6, DPNJAIG5 APE DIAGKAMMAr1G ONLY, KOUII1IS OF PAGEWAYS SHALL DE AT nit OPTION of nit GONIKACTOP UNLESS 36. NO PIPING, DUETS oe EQUIPMENT POKtIGN ro cw:rfICAL EQUIPMENT SHALL DE PER'?11rr5D ro of LOCATED WITHIN E-5 : EQUIPMENT: DC/DC OPTIMIZER SPECIFICATION SHEET CODE orllC,PVVISr NOTED AND SHALL PE GOORDIIIATEP W/TH OTHER' TRADES. THE DEDICATED SPACE ADO✓E THE CLCCTK/GAL ECUIPMEI\Tf, S- 1 : EQUIPMENT: RACKING SYSTEM 17. IF DISTANCES Of CADI -F PUNS ARE DIFFERENT THAN SHOWN; THE CONTRACTOR SHALL NOTIFY CLEGTPICAL ENOINEEe 37 ALL. FIELD INSTALLED JUNCTION, PULL NJD OUTLET BOXED LOCATCP PEHIND MODULES CP PANELS SHALL_ DE Sheet TO V AUDATE THE WIPE SIZE. FINAL DPAWING'S WILL PE PED-LINED AND UPDATED AS APPROPRIATE, AGGE55InLE EXPEGTL'Y OP DY DISPLACEMENT OF A MODUI f (5) OP PANEL CS) Staler") PiY PEMOVADLE FASTENERS, S-2 : EQUIPMENT: RACKING SYSTEM 18. WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT, ARISES ON nit PPAWINGS OP SPECIFICATIONS, nit 58. P.CMOVAL OF A DWP-1NrEPAGTNc IN/ERI ER OP OTHER EQUIPMENT SHALL NOT DISCONNECT THE PONDING GONrPAGTOP SHALL Tat PESPONSIOLE POP PROVIDING AND INSTALLING ALL MATERIAL AND SEKVIGES PCOUIPED DY THE CONNECTION PETWECN THE &POUNDING ELECTRODE GONDUGTOP AND nit PHOTOVOLTAIC SOURCE AND/OP ourPUr S-3 : EQUIPMENT: RACKING SYSTEM 57T/GTt5rGOI D/1/0/J5IJolCDONnitDPAIW/NGSoe /vTHESPECIFICATIONJ5TOC1,IDUetCOMPUTEGOMPUANGC GiPc,IJ1rGKOUVDEDcOA'DUGroP• S-4: EQUIPMENT: RACKING SYSTEM ANT) LONGEVITY OF Pit OPEPADLC Si/STEM KEQUIPED P/'Y THE APCNITECC/ENGINEER', 59. nit KDOF MOUNT-EP PHOTOVOLrA/G MODULES, PANELS: OP SOLARVOLIA(G POLL ROOFING HATER/AL SHALL HA✓r /9. ALL PPOGHUPES; OPERATION MANUALS, CATALOGS, 5HOP Dn LININGS: ETC,. SHALL PC HANDED OVER ro THE OWNER'S THE SAME OK PrrrtR LISTED F/PE-PE5/SrANCE RATING THAN rHt PIA-DING ROOF-COVERING NArEPIAL. S-5 : EQUIPMENT: RACKING SYSTEM, SITE SPECIFIC DETAIL KtPKESENIAINCATIHt COMPLETION OKWOPK. 40. ALL eoorNOUNTEPComDUt WILL PEAMIIUMUM6" OFF n /CKoofSURPAct. S-6 : EQUIPMENT: RACKING SYSTEM BILL OF MATERIALS PLOT PLAN W1W POOL PLAN 1 SCALE: 1/32"= 1'-0" A-2 2"XZ" AH 1 APPROVAL 1 STAMP ,'raft 0 0 w 20 p - jammiiiiiii CAPST9NE 0 L] IP 3011 Oakes Avenue \ / SOLUTIONS -rt �U DESCRIPTION DATE REVISION 9 � � INITIAL 1/1 6/20 1 C.- I ` 0 ' VVV w (E) MAIN SERVICE PANEL(INSIDE) V1‘?"6 4 Solar Developer (E) UTILITY(NET) METER CHRISTOPHER CANAVAN ,r, RICH PHILLIPS o, (N) SOLAREDGE SE6000H-US(OUTSIDE) 4 INTEGRATED DC DISCONNECT System Engineer 7L EQUIPPED WITH AUTOMATIC RAPID SHUTDOWN ERIC WILSON ro TIM WACHTMAN of (N)SOLAR AC DISCONNECT(OUTSIDE) liw Customer Info y _ ,�, CAROL LEE&DOUG ALLEN rA ' • 1 Q 0 p 30 11 OAKES AVE ANACORTES 1 e. WA 98221 } r i ,,, PARCEL#:P58403 \ Project Details �' if: 6.2 I KW �' .� ROOFTOP PV •"iii ' - SYSTEM r .` :,R ; II TT 0111111 a Craft L , \(6) HYUNDAI HIA-S365H1 SOLAR MODULES I AL (6) SOLAR EDGE P370 DC/DC POWER OPTIMIZER L AZIMUTH % t *EVERY MODULE WITH 1 POWER OPTIMIZER / \ 160° ° ARRAY 2* + ,- (1 I) HYUNDAI HIA-S365H1 SOLAR MODULES <,�* MODULE 1 I) SOLAR EDGE P370 DC DC POWER OPTIMIZER HYUNDAI SOLAR ( *EVERY MODULE WITH 1 POWER OPTIMIZER HiA-S365H1 `t- boa'3011 Oakes Avenue INVERTER SOLAREDGE SE6000H-US o • -<_ ESTIMATED ANNUAL PRODUCTION a, 6578kWh/Yr 7 1 Drawing W- ill.". - �: �,•-` \rip• �- SITE PLAN CO11 , x' ', Sheet . r . d q_Z oDv�E.� MOUNTING CALCULATIONS 1 Poor PLAN e A MOUNTING SYSTEM AND MANUFACTURER UNIRAC SOLARMOUNT FLUSH A-3 SCALE: 3/32" = 1'-O" B TOTAL WEIGHT OF MODULES AND RAILS 991.94 LBS MODULE WEIGHT(49.8)X NUMBER OF MODULES 17 846.6 LBS RACKING COMPONENTS 145.3 LBS 2°X2" C TOTAL NUMBER OF ATTACHMENTS POINTS 36 POINTS AHJ APPROVAL D WEIGHT PER ATTACHMENT POINT(B/C) NOT TO EXCEED 45 LBS 27.6 LBS STAMP E MINIMUM RAIL CANTILEVER 16 IN F TOTAL SURFACE AREA OF PV MODULES 21.29 SQI TX MOI)UI.I S 361.9 SO I T G DISTRIBUTED WEIGHT OF PV MODULE ON ROOF(B/F) 991.94 LBS/361.9 SO FT 2.7 PSF APT °NE 'C)‘ (E) MAIN SERVICE PANEL (INSIDE) SOLUTIONS DESCRIPTION DATE REVISION INITIAL 1/1G/20 (E) UTILITY (NET) METER (N) SOLAREDGE SE6000H-US (OUTSIDE) / ` INTEGRATED DC DISCONNECT C EQUIPPED WITH AUTOMATIC RAPID SHUTDOWN N SOLAR AC DISCONNECT (OUTSIDE) Solar Developer ( ) CHRISTOPHER CANAVAN VIS RICH PHILLIPS ,, e System Engineer 0 , ERIC WILSON . i TIM WACHTMAN Customer Info CAROL LEE & DOUG ALLEN 30 I I OAKES AVE ANACORTES WA 98221 O PARCEL#: P58403 _- --- Project Details 6.21 KW ROOFTOP PV SYSTEM ARRAY I TILT (6) HYUNDAI HiA-S365HI SOLAR MODULES 14.5° (6) SOLAR EDGE P370 DC/DC POWER OPTIMIZER AZIMUTH *EVERY MODULE WITH I POWER OPTIMIZER 160° ARRAY 2 SOLAR MODULE ( I I ) HYUNDAI HiA-S365HI SOLAR MODULES HYUNDAI ( I 1 ) SOLAR EDGE P370 DC/DC POWER OPTIMIZER HiA-S365H1 *EVERY MODULE WITH I POWER OPTIMIZER INVERTER SOLAREDGE SE6000H-US ESTIMATED ANNUAL PRODUCTION 6578kWh/Yr 39.06"), *--- PV LAYOUT AND COMPONENT LOCATION HYUNDAIN. Sheet • HiA-S365HI SOLAR MODULES CONDUIT WIRE RATING DEBATE FOR TEMPERATIRE ISC WIRE VOLTAGE DROP CALCULATION 10AWG RUN AMPS VOLTAGE VOLTAGE VOLATGEA LENGTH DROP DROP% TLOAD A "PVC SCHEDULE (3)10 AWG THHN 1118 AWG Cu 10 AWG RATE 90'C= TEMPERATURE DE RATING @ 104'F= ISC x I5.5 x 1.25= 10 AWG OK ,= IF 1-WAY LENGTH OF CIRCUIT EXCEEDS 50' 40 CONDUIT (Black,Red,White) Bond Conductor 40A p.q 1 40A x 0.91=36.4A 15.52A TAW NEC Vd= 0380 =3.1 I volts 50 25 3.11 1.29 236.89 RECALCULATE Vd TO VERIFY LIMITS (Green or bare) 690.8(B)1 I) B (2) (1)8 AWG Cu 10 AWG OK IF 1-WAY LENGTH OF CIRCUIT EXCEEDS 50' "EMT CONDUIT IO AWG THHN Bond Conductor 10 AWG RATE 90'C= TEMPERATURE DE-RATING @)04'F= 40A x 0.91=36.4A ISC x 1.25 x 1.25= IAW NEC Vd=2 x 12 9 x 50'=v90 x 15A=187 volts 50 15 1.g6 0.78 238.14 ?X_7 (Positive,Negative) (Green or bare) 40A 0.91 15.52A 690.8(B)(I) 0380 RECALCULATE Vd TO VERIFY LIMITS AHJ APPROVAL C PVWIREINFREEAIR BARECuEGCOR STAMP MINIMUM I OAWG Cu POSITIVE, OR THHN IN (90'RATED)WIRE NEGATIVE INSULATED EGC IN CONDUIT CONDUIT CONTROLLED FONDNG,ORS ARE umrr DTO SolarEdge Power Optimizer P370 (1) STRING OF 8 HYUNDAI HiA-365H1 MODULES NOT MORE THAN 30 VOL TS AND 210 VOETHOPFERES WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION CONNECTED IN SERIES _ OUTSIDE THE ARRAY. DC Input Power: 370 watts UTILITY METER • NOT MORE!HANOO VOLTS AND).40VOLTAAIPERES WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION • INSIDE THE ARRAY, Maximum Input Voltage:48 Vdc - --- BI-DIRECTIONAL(NET) I IIF VAPID SHUTDOWN INITIATION IS PERFORMED DV EITHER DISCONNECTING THE AC FEED TO THE INVEFTE^. MPPT Range:8 to 48 Vdc OR-If CL 200, FM2S,60Hz THE INVERTER DC SAFETY SWITCH IS READILY ACCESSIBLE-BY TURNING OFF THE DC SAFETY SWITCH GJ Maximum Short Circuit Current(Isc): 11 Adc 2 0 0 o I/// CAPST9NE 1-PHASE,3W, 1 20/240V PHOTOVOLTAIC SYSTEM EQUIPPED WITH Maximum Output Current: 15 Adc per string METER#:U 13 875 617 INVERTER-EMBEDDED AUTOMATIC,RAPID SHUTDOWN SOLUTIONS Maximum Output Voltage:60 Vdc AIL AIL Limitations:8 to 25 Optimizers per string LI +� + _ + DESCRIPTION DATE REVISION Maximum Power Per String: 6000W I I ; ; 111 INITIAL 1/16/20 1 I I,Z SUPPLY SIDE TAP B \L` DICDOI 0 0 o a A o \\...-„__ __ + - - Solar Developer I _ _ CHRISTOPHER CANAVAN oACo RICH PHILLIPS JUNCTION BOX System EngineerA IOODV NEMA 3 I I UA PROV L LISTEDORERIC WILSON PV WIRE IN FREE AIR OR THHN IN CONDUIT Q� Q EQUAL MINIMUM IOA\VG Cu 190'RATED)WIRE TIM WACHTMAN \ POSITIVE,NEGATIVE I�--(1 I_IM BARE Cu EGC OR INSULATED EGC IN CONDUIT ��---�F f u _\ MAXIMUM 295 VOLTAGE DROP Customer Info \v/ CAROL LEE&DOUG ALLEN 1 �� (1) STRING OF 9 HYUNDAI HiA-365HI MODULES 301) OAKESAVEANACORTES a Line LI Q ❑ CONNECTED IN SERIES PARCEL#A g 58403 0\�_ Project Details Load _ 6.21 KW DC O 1 0 0 0 89 ROOFTOP PV p_... SYSTEM J = SOLAREDGE SE6000H-US . 111 /\ /\ TILT OUTPUT: 25A @ 240V ; 1- + - + - 14.5° MAIN SERVICE AC DISCONNECT: NEMA 3R, UL LISTED, TH rA AZIMUTH PANEL VISIBLE,LOCKABLE __I I_I 160° 125A OCPD INTERNAL GFDI JUNCTION NEMA3 EXTERNALLY UL US 3 OPERABLE INTEGRATED DC n A PROV OR DODc D000 0 0 0 7DC DCDc SOLAR MODULE 30A FUSES DISCONNECT WITH RAPID EQUAL + - + + - + - HYUNDAI _ 240V, NEMA 3R SHUTDOWN KIT o >�- �- �- m- HiA-S365HI UL LISTED INVERTER DG22 I NRB J 0 SOLAREDGE SE6000H-US Module Information Inverter Specifications Conductor Calculation Interconnection Method ESTIMATED ANNUAL PRODUCTION 6578kWh/Yr PV MODULE: HYUNDAI HiA-S365HI SOLAREDGE SE6000H-US MAX BRANCH DC CONDUCTOR AMPACITY: CONNECT NEW SOLAR CIRCUIT TO EXISTING Drawing RATED/MAXIMUM AC POWER OUTPUT: 6000W 365W x 9=3285W/380V=8.64Ax 125% 10.81 A ELECTRICAL SYSTEM VIA LINE SIDE TAP;LOAD ELECTRICAL DATA PER MODULE (STC): P370 MAXIMUM OUTPUT CURRENT= 15A SIDE OF NET METER AND SUPPLY SIDE OF MAIN ELECTRICAL LINE MAXIMUM POWER-Pmax (Wp): 365 MAX. CONTINUOUS OUTPUT CURRENT: 25A 10 AWG Cu 90°RATED=40A 91 36.4A 1 -36.4A SERVICE PANEL TAW 705.12 A 230.82 6 690.13 DIAGRAM I' )- I ) I )- I ), MAXIMUM POWER VOLTAGE-Vmpp (V): 39.39 MAX.DC INPUT POWER: 9300@240V 36.4A�10.8I A OK TO INSTALL TAW NEC (C) &690.15 MAXIMUM POWER CURRENT-Impp (A): 9.72 MAX. INPUT VOLTAGE: 480V Sheet 690.8(8)(1-2) OPEN CIRCUIT VOLTAGE Voc(V): 47.21 NOMINAL DC INPUT VOLTAGE: 380V MAX BRANCH AC CONDUCTOR AMPACITY: I 25A RATED BUSS x I20%o= I 50A SHORT CIRCUIT CURRENT Isc 9.77 MAX. INPUT CURRENT: 16.5A@240V 25A MAXIMUM CONT. OUTPUT CURRENT 150A- 125A MAIN OCPD=25A E. 1 (A): MODULE EFFICIENCY: 18.40% CEC WEIGHTED EFFICIENCY: 99p/o4A 25A ALLOWABLE POWER SOURCE INTERCONNECTION MAX. EFFICIENCY: 99.2% 10 AWG Cu 90°=40A x.91=36.4A x 1=36. -30A MINIMUM-SUPPLY SIDE TAP REQUIRED 36.4A>-25A OK TO INSTALL IAW NEC 690.8(B)(1-2) \ ET V ET E t UTILITY/AHJ (PHENOLIC) �`��� �i '� r ` NjMIC7) c POWER TO THIS BUILDING IS SUPPLIED FROM THE AHJ APPROVAL NEC705.12(B)(3) FOLLOWING SOURCES WITH DISCONNECT LOCATED AS SHOWN STAMP 1 WARNING AC SOLAR DISCONNECT PHOTOVOLTAIC DC SOLAR DISCONNECT iiiminsigi TURN OFF PHOTOVOLTAIC NET METER AC DISCONNECT PRIOR TO■� WORKING INSIDE PANEL 0 1110 ;.■Io 0� * CAPST9NE AC DISCONNECTma. NEC 110.21(B)&NEC 705.12 0li SOLUTIONS NEC 690.13(B) :n■ru■ , :�■I'�■■I',■ ,,,,,Q DESCRIPTION DATE REVISION AN IAN ® , MN EnINITIAL IG ZO 1 '..!`..' NEC 705.12(B)(3) A WARNING -w. . INVERTER OUTPUT CONNECTION.DO SUPPLY SIDE TAP NOT RELOCATE AS REQUIRED IF PV Solar Developer THIS OVERCURRENT INTERCONNECTION IS DEVICE. MADE TO SUPPLY SIDE OF CHRISTOPHER CANAVAN RICH PHILLIPS NEC 705.12(B)(2)(3)(b) SERVICE DISCONNECT System Engineer ERIC WILSON SERVICED BY QUALIFIED PERSONNEL ONLY TIMWACHTMAN Customer Info NEC 690.53 CAROL LEE&DOUG ALLEN ADt1E51VE FASTENED 5/6N5; 30 I I OAKES AVE ANACORTES PHOTOVOLTAIC DC DISCONNECT -THE LADEL SYIALL DE SU[TADLE FOP PIE ENV/PONMENT WYIERE 8-15 INSTALLED. WA 98221 MAXIMUM VOLTAGE 480 V.c -WYtERE REQUIRED E1-5EWi1EPE IN 77115 CODE,ALL FIELD APPLIED LADELS,WAPNIN65,ANP PARCEL#:P58403 MAXIMUM CIRCUIT CURRENT MEM MARKIN65 5t1OULD COMPLYWICt1 ANSI Z535,4[NEC IIO,2I09 FIELD NAPKINS], Project Details -ADt1E5IVE FASTENED 5/SN5 MAY DE ACCEPTADLE lF PROPERLY APYlEPED.VINYL 5/GN5 SYIALL 6.2 I KW NEC 690.56 DEWEATHEPPE5I5TANT[IFC 605.11,131 ROOFTOP PV SOLAR PV SYSTEM EQUIPPED PHOTOVOLTAIC SYSTEM 1, ALL EOUIPMENT TO DE LISTED DY UL OR 07-11EP NM__,AND LADELED FOP SYSTEM WITH RAPID SHUTDOWN w �"""° — EQUIPPED WITH RAPID lTSAPPLICATION, TILT S DEGREE G WET ENVIRONMENT,f SHUTDOWN 2,ALL CONDUCTORS 5tIALL PE GOPPEP,PATER FOP GOO V AND 90 14.5° �' TURN RAPID SHUTDOWN ...;,:..:: SWITCH TO THE ' NEC 690.31 G)(3)&(4) 3,WIPING,CONDUIT,AND RACEWAYS MOUNTED ON PODFTOPS ShALL DE AZIMUTH "OFF"POSITION TO !Y :. 160° SHUTDOWN PV SYSTEM -_ wq WARNING: PHOTOVOLTAIC POUTED DIPEGTLY TO,AND LOCATED A5CLOSEA5P055IDLETOTIIE SAND REDUCE HOCK HAZARD I POWER SOURCE NEAREST RIDGE,MP,OP VALLEY, SOLAR MODULE :NI'"art '.f4 IN THE ARRAY 4.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL HYUNDAI NEC 690.56(C)(1)(a) EOUIPMENT 5I1ALL COMPLYWITi1 NEC 110,26, HiA-5365HI ,DRAWINGS INDICATE T11E GENERAL APPANGEMENT OF SYSTEMS, INVERTER PHOTOVOLTAIC DISCONNECT MAXIMUM AC OPERATINGG CURRENT 25 A CONTPAGTOP 511ALL FUPNl511 ALL NEGE55APY OUTLETS,SUPPORTS, SOLAREDGE SE6000H-US MAXIMUM AC OPERATING VOLTAGE 240 VAC FITTINGS AND ACCE550P1E5 TO FULFILL APPLICADLE CODES AND ESTIMATED ANNUAL PRODUCTION NEC 690.54 STANDARDS, 6578kWh/Yr 6,Wl1EPE SIZES OF JUNCTION PDXES,PAGEWAYS,AND CONDUITS APE Drawing NOT SPECIFIED,Tl1E CONTPAGTOP 5tIALL 5/ZE TI1EM ACCORDINGLY, ELECTRIC SHOCK HAZARD RAPID SHUTDOWN WARNING: PHOTOVOLTAIC -,ALLWIPETEPMINAT/ON55Y1ALLPEAPPPOPPIATELYLAPELEDAND LABELING INFORMATION DO NOT TOUCH TERMINALS SWITCH FOR SOLAR • PEADILYVl5IPLE. TERMINALS ON BOTH LINE AND POWER SOURCE 8,MODULE GROUNDING GLlPS TO DE INSTALLED DETWEEN MODULE LOAD SIDES MAY BE ENERGIZED PV SYSTEM NEC 690.31 G 3 & Sheet IN THE OPEN POSITION• NEC 690.56(C)(3) ( )( ) (4) FRAME AND MODULE 5UPPOPT PAIL,PEP TI>E GROUNDING CLIP NEC 690.13(B) & NEC 690.115(D) SYSTEM DC CIRCUIT CONDUCTORS.EXPOSED RACEWAYS,CABLE TRAYS&OTHER WIRING METHODS. COVERS OR ENCLOSURES OF PULL BOXES&JUNCTION BOXES.CONDUIT BODIES IN WHICH ANY OF MANUFACTURER'S INSTRUCT/ON, THE AVAILABLE CONDUIT OPENINGS ARE UNUSED. 9,MODULE SUPPORT PAIL TO PE PONDED TO CONTINUOUS COPPED G,E,G, E._2 LABELS OR MARKINGS SHALL BE VISIBLE AFTER INSTALLATION.REFLECTIVE WITH I"UPPERCASE,WHITE VIA WEEP LUG OP ILSCO GPL-4D0T LAY-IN LUG, ON RED.EVERY SECTION OF THE WIRING SYSTEM SEPARATED BY ENCLOSURES,WALLS,PARTITIONS,CEILINGS,OR FLOORS.SPACING BETWEEN LABELS OR MARKINGS SHALL NOT BE MORE THAN 10' /0,T11E POLARITY OF TI iN E GROUNDED CONDUCTORS 15 NEGATIVE 110.• Electrical Characteristics Mono-Crystalline Type(HiA-S HI) SOLAR MODULE O� ��� 2X2° HYUNDAI 1111111111111*1111411111� AHJ APPROVAL Nominal Output F I 360 365 370 375 380 385 STAMP i 47.21 47,40 47.61 47.80 48.00 HI r�-Mill � Open Clrcuti Voltage ., .I 47 01Mono-Crystalline Type ��� Short Circuit Current l; 9.69 9.77 9.85 9.93 10.01 10.08 HiA-S360H1 HIA-S365H1 HiA-S370H1 HIA-S375H1 �����112� Voltage at Pmax 39.20 39.39 39.60 39.81 40.02 40.21 HIA-S380H1 HiA-S385H1 ���� - SERIES �--.1 1.11 Current at Pmax i 1 , I 9.18 9.27 9.35 9.43 9.50 9.58 -��--- Module Efficiency j 18,10 18.40 18.65 18.90 19.15 19.40 r�® �- Cell Type j mono-crystalline silicon .mme �-���_ Maximum System Voltage 1,500 --- -� Temperature Coefficient of Pmax -0.417 �ir� 4CAPST9NE Tem erature Coefficient of Voc ",+ -0.306 _ ... --- IIU A II Temperature Coefficient of Isc : �; +O.U46 L V T I O 1 S <1 44o � 11811111�� 'All data at SIC(Standard Test Conditions)Above data may be changed without prior notice. DESCRIPTION DATE REVISION ,50 -r 1� INITIAL 1/ 6/20 i Cells For commercial UL 1,500V More Power & Utility IEC 1,500V Generation INITIAL Applications Saves BOS Costs In Low Light ���MI � Mechanical Characteristics Installation Safety Guide � m����� •Only qualified personnel should install or �� Dimensions 992 mm(39.06")(W)x 2,000 mm(78.74")(L)x 40 mm(1.57")(H) perform maintenance. �`�wa�� • Be aware of dangerous high DC voltage. �111111111M11111 Weight Approx.22.6 kg(49.8 ibs) • Do not damage or scratch the rear surface Solar Developer Solar Cells 144 half cells(2 parallel x 72 half cells in series) of the module. glA • Do not handle or install modules when they CHRISTOPHER CANAVAN • ' 4 • mm2(12AWG)cables with polarized weatherproof connectors, are wet, RICH PHILLIPS l r �� Output Cables III.- i M �( Anti-LID / PID Mechanical Strength IEC certified{UL listed and UL 4703 certified),Length 1.2 m(47 ) Nominal Operating 45°C t 2 System Engineer PERL Technologyt t t Cell Temperature Junction Box 1P68,weatherproof,IEC certified(UL listed) PERL technology provides ultra-high Both LID(Light Induced Degradation) and Tempered glass and reinforced frame Operating Temperature -40-85°C ERIC WILSON Bypass Diodes 3 bypass diodes to prevent power decrease by partial shade Maximum TIM WACHTMAN efficiency with better performance in low PID(Potential Induced Degradation) are design withstand rigorous weather DC 1,500V irradiation. Maximizes installation capacity strictlyeliminated to ensure higher actual conditions such as heavysnow and strongSystem Voltage p ty g Front:Anti reflection coated glass__Construction Maximum Customer info in limited space. yield during lifetime. wind. Encapsulant:EVA I Back Sheet:Weatherproof film Reverse Current 20A CAROL LEE & DOUG ALLEN Frame Clear anodized aluminum alloy type 6063 Maximum Front 113 psf(>400 Pa) 30 I I OAKES AVE ANACORTES Test Load Rear 50 psf (2,400 Pal �-._---------- WA 9822 4 N a 414 VDE PARCEL#: P58403 Reliable Warranty ,....A........ Corrosion Resistant UL / VDE Test Labs Module Diagram (unit:mnl) I-V Curves Project Details HYUNDAI AMww.A Global brand with powerful financial Various tests under harsh environmental Hyundai's R&D center is an accredited test Mono-Crystalline Current[A] 6.2 I KW Si Type-Front Side View ROOFTOP PV strength provide reliable 25-year conditions such as ammonia and salt-mist laboratory of both UL and VDE. _ ii SYSTEM warranty. passed. I i 1 111 HI It, ICI lirz _ 9 - � 11 Iilillti 1i11 li i ii�i�i a TILT II III 1IIIIll 111In II m ' - 11TI 1 n ilium 11J 6 \ 14.5° ti11 #11 1111I 11t q . Incid.Ind=1,000W1rtr 11 I III_ 11111 f Operating Cell Temp=5 C AZIMUTH III I III 1 111( I 3 - Operating Cell Temp=25°C Hyundai's Warranty Provisions About Hyundai Solar I I III t Mir 1 2 - °perating Cell Temp=45'C 11 160° III I 1 I sl / , - -- OperawgCell-temp=65°c Established in 1972, Hyundai Heavy Industries (HIfl) is one of the most trusted names in the heavy III 1 1 , I , ;b o --- --a - 40 - 1 • 10-Year Product Warranty { 4 o ,o so 30 35 - SOLAR MODULE ).I I III I N,n l II9 industries sector with 48,000 employees and more than 40 Billion USE) in annual sales (2015). As It n 1 1111 1111011 nr1I - Voltage►V1 YEARS • On materials and workmanship s idle) I i 1 tllll, I li I a global leader and innovator, Hyundai Heavy Industries is committed to building a future growth a ti p t11111�1�11( Current[A) HYUNDAI u U 111 I ttn#fill in '7 HiA S365H1 engine by developing and investing heavily in the field of renewable energy. 11,1 i•1 i i I' �1f1IJ Ii III L I u • 25-Year Performance Warranty �I��,t g ;acid.Wad=1,000Y1/m' 25 Started as a core business division of I-iHI, Hyundai Solar (Hyundai Heavy Industries Green Energy) )1 i_. 1i n I.1u1Ui I # INVERTER YEARS • Initial year: 97% ,. , _ , 1HI Iltl t 7- kxldtrra1=800W1m,now stands as an independent company and an affiliate of HHI as from December 2016. Vdc haver 1I1 Milli r ° - SOLAREDGE SE6000H US • Linear warranty after second year: strong pride in providing high-quality solar PV products to more than 3,000 customers worldwide. ; II i triii _ It 11_111L 11 i I 5 - Incid.Irrad=600W/m7 �, h-. .-.�._11111�-,.,,,R,_II"hh.I.1 with 0i.7%,p annual degradation, _ --- 4 Batt 1 r,,,,, 35 3 .Inclalrrad=400Wlm' ESTIMATED ANNUAL PRODUCTION 80%is guaranteed up to 25 years 1 - --Incid.land=200Wvm' A 6578kWh/Yr co."--- to w n 40 5'0 'ro'tage[VI Drawing Certification EQUIPMENT: i'` r E c 0 In IK ell15 aria 1FC 61 730 New Stonclary by 1w SLID • Ill 1/03 l isles by tll Type MOT Hr Uass A) AHYUNDAI A. HYUNDAI PV MODULE SPECIFICATION SHEET LISTED GREEN ENERGY GREEN ENERGY Sheet Sales&Marketing Printed half :05/2019 Printed Date:05/2019 r'iinied cn rsc term c i vwnv.tlhiczreen.com 55.Bundang-ro, Bundang-gu,Seongnam-si,Gyeonggi-do, 13591,Korea 1 info@hhigreen.com eco,r uJyp per, Pse Tel:America:+1-212-220-5764.Japan:+81-3-6717-4435 I Fax:+82-31-8006-6967 Europe: +49-89-71042-2023.Australia:+61-2-9238-2283 E.."3 Single Phase Inverter2„X2„ with H i -Wave Technology for [North Amerricl AHJ APPROVALSTAMP Si SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ Phase Inverter SE7600H-US / SE10000H-US / SE11400H-US SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US HDVVave Technology OUTPUT with M Rated AC Power Output 3000 3Boo @�40v 5000 @ 20BV 11400 @ 240V VA 3300 @ 208V 5000 5000 @ 208V 7b00 10000 10000 @ 208V for ] ° 3ROt1 fo_l 740V 6000 @ 240V I 11400 @ 240V North �� �'Q(C Maximum AC(rower Output 3000 3300 @ 208V 5000 I 5000 @ 208V 7600 10000 10000 @ 208V VA - AC Output Voltage Min. Nom. Max. ✓ ✓ ✓ ✓ ✓ I ✓ Vac CAPSNE SE3000H-US / SE3800H-US / SE5000H-US / SE6000H US / (211 240 2lta __ SE7600H-US / SE10000H-US / SE11400H-US AC output Voltage Min. Nom. Max. ✓ ✓ Vac SOLUTIONS , (183-208-229) ✓ j --_... _ 1 2-25 m AC Frequency(Nominal) 59.3-60-60.50) --- Hz 7:1 Maximum Continuous OutputDESCRIPTION DATE REVISION YEAR 12-5...-_...__,__ 16 21 25 32m.._..— 42 ------ 47.5 ___-- A -- 1 Current @24oV — ---- --- — -- INITIAL 1/16/20 I Swarm7 111 WARRANTY Maximum Continuous Output _ Current @206V 16 i 24 48.5 A GFDI Threshold 1 A O solar:1 tr,, r=1 Utility Monitoring,islanding Protection, Yes Country Configurable Thresholds INPUT ___ _. Solar Developer i Maximum DC Power©240V 4650 5900 7750 9300 11800 — 15500 17650 I W Maximum DC Power 0208V - 5100 7750 - 15500 W CHRISTOPHER CANAVAN RICH PHILLIPS O c fransformel=less,Ungrounded Yes NM Maximum Input Voltage - 480 _ - � - - Vdc System Engineer Ca o O +D • • • •• Nominal DC Input Voltage-- — — ___ --- 380 l 400 - __ Vdc _ ERIC WILSON ti • v Maximum Input Current @240V ' 8.5 10.5 — 13.5-- I 16.5 20 — —27 I 30.5 I Adc TIM VVACHTMAN O n (.-1 Maximum Input Current @208Vf21 - 9 - 13.5 - - I 27 -- Adc o n Max.Input Short Circuit Current -- 45 - --- Adc Customer Info Reverse-Polarity Protection Yes CAROL LEE & DOUG ALLEN ,� Ground-Fault Isolation Detection 600ku Sensitivity 301 I OAKES AVE ANACORTES Maximum Inverter Efficiency 99 I 99.2 WA 98221 / 0 CEC Weighted Efficiency99 99 @ 240V PARCEL#: P58403 g98.5 @ 208V +e Nighttime Power Consumption <2.5 W Project Details -r ADDITIONAL FEATURES 6.2 I KW ROOFTOP PV Supported Communication Interfaces R5485,Ethernet,ZigBee(optional),Cellular(optional) SYSTEM Revenue Grade Data,ANSI C12.20 Optional°' ___________________________ -______ ____ Rapid Shutdown-NEC 2014 and —-- -- Automatic Rapid Shutdown upon AC Grid Disconnect TILT installation 1 1 2017 690.12 p 14.5° ) `l[�l(11� C 1 nst u la l O�11 1fa9�`lt 11! C-1 �_> �1 ` `LI CSC'ill l O CSC��� STANDARD COMPLIANCE AZIMUTH Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 I Specifically designed to work with Extremely small Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) 160° power optimizers Emissions FCC Part 15 Class B SOLAR MODULE INSTALLATION SPECIFICATIONS Record-breaking efficiency Built-in module-level monitoring ---- - - - ____._ HYUNDAI AC Output Conduit Size/AWG Range _w_ __ 1°Maximum/14-6 AWG --- 1'Maximum/14-4 AWG H IA S365H I DC Input Conduit Size/#of Strings/ 1" Maximum/1-2 strings/14-6 AWG 1"Maximum/1-3 strings/14-6 AWG Fixed voltage inverter for longer strings Outdoor and indoor installation AWG Range --_--_._____ __-_ ------- -------- - _ _ INVERTER Dimensions with Safety Switch 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 x 185 y in (HxwxD) Mtn SOLAREDGE SE6000H-US Integrated arc fault protection and rapid shutdown for Optional: Revenue grade data, ANSI C12.20 Weight with Safety Switch 22/10 I 25.1/114 26.2/11.9 38.8/17.6 lb/kg ESTIMATED ANNUAL PRODUCTION NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy) Noise <25 <50 dBA 6578kWh/Yr Cooling Natural Convection UL1741 SA certified, for CPUC Rule 21 grid Operating Temperature Range -13 to+140/-25 to+6V1(-40°F/-40°C option)i`} °F/'C Drawing compliance Protection Rating NEMA 4X(inverter with Safety Switch) EQUIPMENT: ",For other regional settings please contact SolarEdge support INVERTER SPECIFICATION SHEET rr A higher current source may be used;the inverter will limit its input current to the values stated S o I a r ' , , Revenue`' grade Ling terinformation P/N:rma SExxion' H to.hil NNC2 solaredge.com tr '"For p e inve info:matiun xxi-i-c.hnps-J/wvrwsolarcdge-com/sitrsfd tatilt/hies/se temr,mature-deratinrf nate na.l%i1 '-40 version p/N;5ExxxxH•US00014Ntpt Sheet •b SotarEdge Technologies,Inc.Alf rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All Ro H S other trademarks mentioned herein are trademarks of their respective owners.Date:03/2019/V01/ENG NAM.Subject to change without notice. 2"X2° CC AHJ APPROVAL STAMP _li :111 a r all ll . INF- Lu solar . s , .. Power Optimizer P320 / P370 / P400 / P405 / P505 NI _ iliwom P370 1 • Power Optimizer (typical module compatibility) P320 (for high-power 60-cell modules) 60 and 72-cell modules) P400 modules) P405 modules) P505 OPTIMIZER MODEL (for higher-power (for 72&96-cell (for thin film (for higher current modules) „. INPUT MINII - ---- P320 / P370 / P400 / P405 / P505 I- -- Rated Input DC Poweriii Absolute Maximum Input Voltage 320 48 370 60 400 80 405 125(2) 505 - W IINI 83(') Vdc , • --.,... (Voc at lowest temperature) MPPT Operating Range 8-48 8-60 8-80 12.5-105 12.5-83 Vdc CAPST A NE Maximum Short Circuit Current(Isc) 11 10.1 14 Adc CDMaximum DC Input Current 13.75 12.63 17.5 Adc SOLUTIONS -',,, Maximum Efficiency 99.5 % DESCRIPTION DATE REVISION Weighted Efficiency 98.8 98.6 % Er _Overvoltage Category II _ INITIAL 1/1 6/20 1 ' 1' s ) .--‘\ ,' -N OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) I Lill Maximum Output Current 15 Adc Maximum Output Voltage 60 I 85 Vdc . 1 . ; . I , Illii OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power lutenummommisis 1±0.1 Vdc Optimizer Solar Developer 11 i !I I II STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 - CHRISTOPHER CANAVAN I . ' '1 i ' vemer0 ' i [ 1 . • e,,, Safety IEC62109-1(class II safety),UL1741 RICH PHILLIPS ' 1 1 1 1 , ,45' 1 Clem ' ; f25{oss RoHS Yes _ __ ____. , . . ------- System Engineer INSTALLATION SPECIFICATIONS ' I I i `4„. i Maximum Allowed System Voltage 1000 Vdc . ' I 1 i 1 Y °'•Jazia ERIC WILSON Compatible inverters All SolarEdge Single Phase and Three Phase inverters TIM WACHTMAN 128 x 152 x 36/ 128 x 152 x 50/ 128 x 152 x 59/ Dimensions(W x L x H) 128 x 152 x 28/5 x 5.97 x 1.1 mm/in 5 x 5.97 x 1.42 5 x 5.97 x 1.96 5 x 5.97 x2.32 Customer Info Weight(including cables) 630/1.4 750/1.7 845/1.9 1064/2.3 gr/lb Input Connector MC40 CAROL LEE & DOUG ALLEN Output Wire Type/Connector I ) Double Insulated;MC4 ft 30 I I OAKES AVE ANACORTES Output Wire Length 0.95/3.0 1.2/3.9 m/ WA 98221 Operating Temperature Range -40-+85/-40-+185 'C/*F PARCEL#: P58403 Protection Rating IP68/NEMA6P Project Details Relative Humidity 0-100 % (n Rated STC power of the module.Module of up to+5%power tolerance allowed 6.2 I KW (n NEC 2017 requires max input voltage be not more than BOV ROOFTOP PV M For other connector types please contact SolarEdge ------- - -------- ----------- SYSTEM PV SYSTEM DESIGN USING SINGLE PHASE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER(05) HD-WAVE - TILT Minimum String Length P320,P370,P400 8 10 18 (Power Optimizers) P405/P505 6 8 14 I 4.5° ... „ Maximum String Length 25 25 5001 AZIMUTH (Power Optimizers) PV power optimization at the module-level , 5700(6000 with I 60° Maximum Power per String SE7600-US-SE11400- 5250 600017) 12750181 \A) Specifically designed to work with SolarEdge inverters us) SOLAR MODULE Parallel Strings of Different Lengths HYUNDAI Up to 25% more energy Yes or orientations 1 HiA-S365HI Superior efficiency (99.5%) --------- -- • 14)For detailed string sizing Information refer to:http://www.solaredge.corn/sites/default/files/string_sizing_na.Pdf (&)It is not allowed to mix P405/P505 with P320/P370/P400/13600/P700/P800 in one string INVERTER , Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading to A string with more than 30 optimizers does not meet NEC rapid shutdown requirements;safety voltage will be above the 30V requirement II For SE14AKUS/5E43.2KUS:It is allowed to Install up to 6,500W per string when 3 strings are connected to the inverter(3 strings per unit for SE43.2KUS)and when the maximum power difference between the Flexible system design for maximum space utilization strings is up to 1,000W SOL/WEDGE SE6000H-US tai For SE3OKUS/SE33.3KUS/SE66.6KUS/SE100KUS:It Is allowed to install up to 15,000W per string when 3 strings are connected to the inverter(3 strings per unit for 5E66.6KU5/SE100KUS)and when the maximum • Fast installation with a single bolt power difference between the strings is up to 2,000W ESTIMATED ANNUAL PRODUCTION Next generation maintenance with module-level monitoring 6578kWh/Yr - Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Drawing - Module-level voltage shutdown for installer and firefighter safety C E a EQUIPMENT: DC/DC POWER OPTIMIZER SPECIFICATION SHEET www.solaredge.us it SolarEdge Technologies.Inc.All rights reserved.SOLAREDGE.the SolarEdge logo,OPTIMIZED BY SOLAREDGE . Sheet are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:10/2018/VOVENG NAM.Subject to change without notice. __ _ Ii i itp-_---1 1 I -1 I ___.) ZX2° PRO SERIES END CLAMP PRO SERIES MID CLAMP AHJ APPROVAL STAMP cD_______... , 11 �� 11 1 2�� 6 6, END CLAMP 1 1" r'_ MID CLAMP O t I CAPSTNE 30mmto51mm � _ SOLUTIONS MODULE FRAME ' DESCRIPTION DATE REVISION PART#TABLE INITIAL 1/1 G/20 P/N DESCRIPTION ir.-- 302035M ENDCLAMP PRO 302030M MIDCLAMP PRO-MILL 302030D MIDCLAMP PRO-DRK Solar Developer t. CHRISTOPHER CANAVAN RICH PHILLIPS System Engineer ERIC WILSON TIM WACHTMAN PART#TABLE �0546" Customer Info 1 P/N DESCRIPTION I � —WA 11 CAROL LEE&DOUG ALLEN I' D 302027C SM BND MIDCLAMP BC SS 17/" 301 I OAKES AVE ANACORTES MID CLAMP WA 98221 302027D SM BND MIDCLAMP BC DRK SS 1 PARCEL#:P58403 302028C SM BND MIDCLAMP EF SS Project Details 302028D SM BND MIDCLAMP EF DRK SS 1s/6 13�6" 6.2 I KW ROOFTOP PV 302029C SM BND MIDCLAMP DK SS SYSTEM ® END CLAMP 302029D SM BND MIDCLAMP DK DRK SS TILT FOR BONDING END CLAMP VARIES-REFER TO 14.5° 14n� 1-0— SHEET SM-P05 AZIMUTH REFER TO SHEET SM-P05 160° ��vit SOLAR MODULE END CAP HYUNDAI INCLUDED WITH END CLAMP -, BONDING SM MID CLAMP BONDING SM END CLAMP HiA-S365H1 INVERTER SOLAREDGE SE6000H-US , PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE ,-� PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE Q ESTIMATED ANNUAL PRODUCTION IN I ALL DIMENSIONS ARE CD i��U N I RAC i� ALL DIMENSIONS ARE 6578kWh�rr DRAWING TYPE: PART&ASSEMBLY NOMINAL DRAWING TYPE: PART&ASSEMBLY NOMINAL � Q "C ` Drawing 1411 BROADWAY BLVD.NE 1411 BROADWAY BLVD.NE PRO SERIES Z BONDING TOP e ALBUQUERQUE,NM 87102 USA DESCRIPTION: PRODUCT PROTECTED BY Cn ALBUQUERQUE,NM 87102 USA DESCRIPTION: PRODUCT PROTECTED BY z EQUIPMENT: BONDING CLAMPS CLAMPS RACKING SYSTEM PHONE:505.242.6411 ONE OR MORE US PATENTS PHONE:505.242.6411 ONE OR MORE US PATENTS WWW.UNIRAC.COM REVISION DATE: 10/26/2017 LEGAL NOTICE J SHEET WWW.UNIRAC.COM J REVISION DATE: 10/26/2017 S. LEGAL NOTICE J SHEET i Sheet s— i 2"X2° NOTES: AHJ APPROVAL 1.INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S WRITTEN SPECIFICATIONS s�� STAMP AND INSTALLATION INSTRUCTIONS. h /16 " 2. PACKAGING: KITS OF 10 ('. ` 3/" 16 IFLANGE NUT II �. 3/" 16X3/"TBOLT ��\ 213/6' idill1111111111 ifi,"-NNI f - iiu ���� CAPST9NE 12" 1,�['"-- "--.1 k 2" f SOLUTIONS DESCRIPTION DATE REVISION /s" L-FOOT INITIAL 1/1 G/20 et. I Solar Developer OUNI!7.,, CHRISTOPHER CANAVAN y� MINIMUM 3 5/8" L RICH PHILLIPS -2" y MINIMUM 4" System Engineer 8 1/16" MINIMUM 2 ° HEIGHT J 13�6 HEIGHT 1 I ERIC WILSON HEIGHT i TIM WACHTMAN %"-16 X 1" SS SERRATED T-BOLT Customer Info CAROL LEE& 3/g" % ALLEN " HEX FLANGE NUT 301 1 OAKESAVEOUG ANACO TES 1 14" WA 98221 PARCEL#:P58403 �-„� Project Details 2 7/n U. -11 6.21KW "� 'i L�- I ROOFTOP PV,� MAXIMUM 415/6" I SYSTEM I 1 P p1 --- MAXIMUM HEIGHT TILT 4 9/6" -- ni MAXIMUM 31116" HEIGHT I4.5° W ; HEIGHT i AZIMUTH -- , - 160° PART#TABLE SOLAR MODULE P/N DESCRIPTION SOLARMOUNT LIGHT SOLARMOUNT STANDARD SOLARMOUNT HD HYUNDAI 004055M FLASHKIT PRO MILL HiA-S365HI 004055D FLASHKIT PRO DRK ON L-FOOT ON L-FOOT ON L-FOOT INVERTER SOLAREDGE SE6000H-US `' p ` PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE II `' PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE, ,--I ESTIMATED ANNUAL PRODUCTION ii'U I V I�1 ! ALL DIMENSIONS ARE p :II U I V I RAC ALL DIMENSIONS ARE 6578kWh/Yr DRAWING TYPE: KIT DETAIL NOMINAL a DRAWING TYPE: PART&ASSEMBLY NOMINAL , 1 Drawing 1411 BROADWAY BLVD,NE E 1411 BROADWAY BLVD,NE e ALBUQUERQUE,NM 87102 USA DESCRIPTION: FLASHKIT PRO PRODUCT PROTECTED BY (I) ALBUQUERQUE,NM 87102 USA DESCRIPTION: L-FOOT PRODUCT PROTECTED BY (1) EQUIPMENT: PHONE:505,242.6411 ONE OR MORE US PATENTS PHONE:505.242.6411 ONE OR MORE US PATENTS RACKING SYSTEM WWW.UNIRAC.COM REVISION DATE: 9/24/2018 LEGAL NOTICE SHEET WWW.UNIRAC,COM REVISION DATE: 11/19/2018 N. LEGAL NOTICE SHEET Sheet S-2 2°X2" BONDING SPLICE BAR 1/" BOLT LOCATION AHJ TAMPVAL O O O O ate• ,, 7 , 4-- en ,,,, ,, .2 „........„ �15�6��� ,... 4" I CAPST9NE SOLUTIONS DESCRIPTION DATE REVISION 2 9/6" ' 0 INITIAL 1/1 6/20 I \\\_ Solar Developer CHRISTOPHER CANAVAN RICH PHILLIPS #12 X 3A"SELF DRILLING SS SCREWS INCLUDED 3/8" BOLT LOCATION- System Engineer TYPICAL SPLICE BAR DETAIL ERIC WILSON r / 0 TIM WACHTMAN 1„H H / 1 Customer Info CAROL LEE&DOUG ALLEN PART#TABLE 30 I I OAKES AVE ANACORTES WA 9822I P/N DESCRIPTION LENGTH PARCEL#:P58403 320132M SM RAIL 132"MILL 132" Project Details 310132C SM RAIL 132"CLR 132" 6.2 I KW ROOFTOP PV NOTE THAT ONLY 2 SCREWS ARE 320168M SM RAIL 168"MILL 168" SYSTEM USED AT AN EXPANSION JOINT. 310168C SM RAIL 168"CLR 168" TILT TYPICAL EXPANSION JOINT DETAIL THE SPLICE BAR DOES NOT BOND ACROSS AN EXPANSION JOINT. 320168D SM RAIL 168"DRK 168" 14.5° SEE INSTALLATION GUIDE FOR 320208M SM RAIL 208"MILL 208" AZIMUTH INSTRUCTION. 160° PART#TABLE 310208C SM RAIL 208"CLR 208" P/N DESCRIPTION 320240M SM RAIL 240"MILL 240" SOLAR MODULE HYUNDAI 303018C BND SPLICE BAR SERRATED CLR 310240C SM RAIL 240"CLR 240" HIA-S365H1 303018D BND SPLICE BAR SERRATED DRK 310240D SM RAIL 240"DRK 240" INVERTER SOLAREDGE SE6000H-US .. U w ,I Rr PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE �� /� PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE ESTIMATED ANNUAL PRODUCTION ��� Iv l ALL DIMENSIONS ARE o ii'U N I RAC ALL DIMENSIONS ARE 6578kWh/Yr DRAWING TYPE: PART&ASSEMBLY NOMINAL Q DRAWING TYPE: PART DETAIL NOMINAL o- Drawing 1411 BROADWAY BLVD.NE g 1411 BROADWAY BLVD.NE r 1 ALBUQUERQUE,NM 87102 USA DESCRIPTION: BONDING SPLICE PRODUCT PROTECTED BY' LA ALBUQUERQUE,NM 87102 USA DESCRIPTION: STANDARD RAIL PRODUCT PROTECTED BY t/1 EQUIPMENT: PHONE:505.242.6411 BAR ONE OR MORE US PATENTS PHONE:505.242.6411 ONE OR MORE US PATENTS RACKING SYSTEM WWW.UNIRAC,COM REVISION DATE: 9/27/2017 LEGAL NOTICE i SHEET WWW,UNIRAC.COM REVISION DATE: 9/11/2017 ` LEGAL NOTICE J SHEET Sheet S-3 2"X2" AHJ APPROVAL STAMP 1/4"BOLT LOCATION Ar Ai 1/4"BOLT LOCATION—\ issimaimi...._ r3 n r r --� CAPST9NE BOTTOM CLIP SLOT^� SOLUTION S / L DESCRIPTION DATE REVISION ' INITIAL 1/1 6/20 I 1 ll�bn 3" Solar Developer 3/"BOLT LOCATION P9-1 - CHRISTOPHER CANAVAN RICH PHILLIPS System Engineer / 1 _I ERIC WILSON J 3/"BOLT LOCATION TIM WACHTMAN 0Customer Info Z_. CAROL LEE&DOUG ALLEN 301 I OAKES AVE ANACORTES 1 WA 9822 I PARCEL#:P58403 1�/" Project Details 6.21 KW ROOFTOP PV SYSTEM TILT PART#TABLE PART#TABLE 14.5° P/N DESCRIPTION LENGTH P/N DESCRIPTION LENGTH AZIMUTH 315168M SM LIGHT RAIL 168"MILL 168" 410144M SMHD,RAIL 144"MILL 144" 160° 315168D SM LIGHT RAIL 168"DRK 168" 410168M SMHD,RAIL 168"MILL 168" SOLAR MODULE 315240M SM LIGHT RAIL 240"MILL 240" 410204M SMHD,RAIL 204"MILL 204" HYUNDAI HIA-S365HI 315240D SM LIGHT RAIL 240"DRK 240" 410240M SMHD,RAIL 240"MILL 240" INVERTER SOLAREDGE SE6000H-US •■i U N IRA( PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE ��U N I RAC PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE ESTIMATED ANNUAL PRODUCTION ■i ALL DIMENSIONS ARE p ALL DIMENSIONS ARE 657ekWr/Y DRAWING TYPE: PART DETAIL NOMINAL a •'. DRAWING TYPE: PART DETAIL NOMINAL o. Drawing 1411 BROADWAY BLVD.NE i 1411 BROADWAY BLVD,NE E ALBUQUERQUE,NM 87102 USA DESCRIPTION: LIGHT RAIL PRODUCT PROTECTED BY (I) ALBUQUERQUE,NM 87102 USA DESCRIPTION: HD RAIL PRODUCT PROTECTED BY V) EQUIPMENT: PHONE:505.242,6411 ONE OR MORE US PATENTS PHONE:505.242.6411 ONE OR MORE US PATENTS RACKING SYSTEM WWW.UNIRAC.COM REVISION DATE: 9/11/2017 LEGAL NOTICE SHEET WWW.UNIRAC,COM REVISION DATE: 9/11/2017 LEGAL NOTICE SHEET Sheet S-4 2"X2° AHJ APPROVAL STAMP ENGINEERING REPORT Array 1 Plan review Inspection ROOF POINT LOAD UP -111.50 lbs DESIGN RAIL SPAN 48.00" CAPST9NE AVERAGE PSF 2.11 psf PRODUCT SOLARMOUNT FLUSH ROOF POINT LOAD DOWN 294.50 lbs MAXIMUM RAIL SPAN 63.00" SOLUTIONS �. MODULE MANUFACTURER Hyundai DESCRIPTION DATE REVISION TOTAL NUMBER OF MODULES 17 MODEL 17 - H1s-S365R1 TOTAL NUMBER OF MODULES: 6 MAXIMUM RAIL CANTILEVER: 16,00" INITIAL 1/1 6/20 I TOTAL KW 6.20 KW MODULE WATTS 365 watts TOTAL KW: 2.19 KW ROOF PITCH: 23° TOTAL AREA -358 ft2 MODULE LENGTH 77.17" ROWS/COLUMNS: 2 / 3 (no gaps) Solar Developer MODULE WIDTH 39.29" NS DIMENSION: - 12,9/1 ft CHRISTOPHER CANAVAN Loads Used for Design RICH PHILLIPS MODULE THICKNESS 1.58" EW DIMENSION: - 9.99 ft System Engineer BUILDING CODE ASCE 7-10 MODULE WEIGHT 50.50 lbs ERIC WILSON TIM WACHTMAN BASIC WIND SPEED 110.00 mph Array2 EXPANSION JOINTS Every40' Customer Info GROUND SNOW LOAD 25.00 psf CAROL LEE & DOUG ALLEN RAILS DIRECTION EW ROOF POINT LOAD UP -111.50 lbs DESIGN RAIL SPAN 48.00" 30 I 1 OAKES AVE ANACORTES SEISMIC(SS) 1,08 WA 98221 BUILDING HEIGHT 30.00 ft PARCEL#: P58403 ELEVATION 4$2,00 ft Project Details ROOF TYPE Shingle ROOF POINT LOAD DOWN 294.50 lbs MAXIMUM RAIL SPAN 63.00" 6.2 I KW WIND EXPOSURE g ROOFTOP PV RAFTER SPACING 24.00" SYSTEM Loads Determined by Zip 98221 TOTAL WEIGHT 991.94 lbs TOTAL NUMBER OF MODULES: 1 1 MAXIMUM RAIL CANTILEVER: 16.00" TILT 14.5° TOTAL KW: 4.02 KW ROOF PITCH: 23° AZIMUTH CITY,STATE Anacortes, WA 160° ROWS/COLUMNS: 2 / 6 (with gaps) BASIC WIND SPEED 110.00 mph SOLAR MODULE NS DIMENSION: - 12.95 ft HYUNDAI HiA-S365HI GROUND SNOW LOAD 0,00 psf EW DIMENSION: -• 20.06 ft INVERTER SOLAREDGE SE6000H-US ESTIMATED ANNUAL PRODUCTION 6578kWh/Yr Drawing EQUIPMENT: RACKING SYSTEM, SITE SPECIFIC DETAIL Sheet 2"X2° DETAILED PARTS DESCRIPTION an AHJ APPROVAL !g------: 0 Rail 320168M SM RAIL 168" MILL 16 Structural aluminum extrusion containing slots that accept module and roof attachment hardware,electrical bonding accessories,and splice bars. --44. -__-_-_----__ Splic: 303019M BND SPLICE BAR PRO SERIES MILL CA? r i °NE r 4 Mill finished aluminum extrusion for joining adjacent lengths of rail to one another. Includes T r` pre-assembled bolts. Uses 1/2"socket for 1-tool system install. LU DESCRIPTION DATE REVISION INITIAL 1/16/20 1 /PI. Mid Clamp 302029C SM I3ND MIDCLANIP DK SS 24 Located between adjacent PV modules, mounts 38-41 mm(1.5-1.61 in)thick modules to rail by clamping module frame from above. Includes T bolt and nut. If mounting on short side of module frame,confirm this is acceptable with PV Solar Developer CHRISTOPHER CANAVAN End Clamp 302023C SM ENDCLAMP D CLR AL 20 RICH PHILLIPS la Mounts 38-40 nun(1.50-1.57 in)thick PV modules to rail by clamping module frame from System Engineer above. Includes T bolt and nut.If mounting on short side of module frame, confirm this is acceptable with PV module manufacturer. ERIC WILSON TIM WACHTMAN Customer Info Microinverter Mounting 008013S MICRO MNT BND T-BOLT 1/4in x 3/4in SS 17 CAROL LEE & DOUG ALLEN Attaches micro inverter flange to beam using 3/4"x 1/4" bonding T Bolt. 30 I I OAKES AVE ANACORTES WA 98221 PARCEL#: P58403 Project Details 6.2 I KW Flashing 004055M FLASHKIT PRO, MILL 10PI< 36 ROOFTOP PV AI • FLASHKIT PRO is the complete attachment solution for composition shingle roofs. Featuring SYSTEM Unirac's patented SHED&SEAL technology,a weather proof system which provides the TILT ultimate protection against roof leaks. Kitted in 10 packs for maximum convenience. Includes mill finish flashing and L-foot,lag with pre-assembled sealing washer, and 3/8"t- 14.5° bolt and nut. AZIMUTH 160° Grounding Lug(Weeb) 008002S GROUND WEEBLUG#1 5 SOLAR MODULE llitr- r For electrical bonding of PV modules and rails.Accepts one 14AWG to 6AWG or two 12 AWG HYUNDAI to 10 AWG copper wires.Tin plated copper body, 1/4"stainless steel fasteners. HiA-S365H1 INVERTER SOLAREDGE SE6000H-US ESTIMATED ANNUAL PRODUCTION 6578kWh/Yr Drawing EQUIPMENT: RACKING SYSTEM BILL OF MATERIALS Sheer ((Na \�I 1 t Jl