Loading...
HomeMy WebLinkAboutPermit File BLD-2019-0293 3938 Rock Ridge Parkway (4) GST Y 0 PLANNING, COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT AihosON /ADDITIONAL INFORMATION COVER SHEET ��� w� .ifng Address:P.O. Box 547, Anacortes, WA 98221 <o6 gnuOf/0 Location: 904 6th Street,Anacortes.WA 98821 II_ FE8 11 Luzil PPhone: (360) 299-1984, Fax: (360) 293-1938 Please use this form to submit revisions or additional information to your permit application. MI Permit/Project#: LI).o Q,C) 02 Date: 02/18/2020 Project Name: Mockos Residence Project Address: 3938 Rock Ridge Parkway,Anacortes,WA 98221 Project Contact: Jeremy McCormick Company Name: Strandberg Construction Inc. Contact Phone: 360-202-1804 Contact Email: Jeremy@strandbergconstruction.com Has the permit been issued yet? El Yes 0 No All revisions must be either clouded or highlighted L wet stamped by an architect/engineer(if applicable). Has this been done? 0 Yes 0 No Is the plan revision or additional information,in response to a plan review letter? ❑ Yes. A copy of the plan review letter with itemized responses to each item is required. El No,the revision or additional information is initiated by the applicant,designer,or builder. If not in response to a Plan Review Letter, please explain the nature of the revisions and/or additional information: Stair Detail as requested by the City Are you submitting a full replacement Q Yes 0 No If not,what page# or title is being replaced: Two full sized copies of all revised /additional information is required. Has this been done? 8 Yes 0 No Check the box next to the type of plan, report, or calculation where revisions or additional information can be found. ❑ Site Plan ❑ Building Plans 0 Structural Plan ❑ Landscape Plan 0 Parking Plan 0 Tree Preservation Plan ❑ Arborist Report ❑ SEPA checklist 0 Wetland Report ❑ Geotechnical Report 0 Storm Drainage Analysis 0 TESC Plan ❑ Civil Plan 0 Lot Coverage Calculations 0 Impervious Surface Calculations ❑ FAR Calculations 0 Grading Plan 0 Survey(Boundary/Topographic) ❑ Mechanical Plan 0 Plumbing Plan 0 Other: Stair Design l No In Floor Heating from 112" to 132" Exampe only not to scale: Down / Upper Floor _ 18 Risers / 1 IL / 16 T- 3/8" x 24" Plate RFW ., _ r- - - - - -� ,- I- " t f— — — — I I Floor to Floor Height as measured 135-3/4" 19-1/4" I ' L — Base_Ela.a ,_ Red Oxide Prime Only 4 Top Tread Flush to Finish Floor I I Based on a landing platform design from Strandberg (modification TBD) L — _- — — — J r— — — — — -1 /- - - - - , Dimensions Based on a 2" Tread Thickness = I I I 1 Ground Floor to Finish Landing - 75-7/16" 4 r- - - -- - _1 r- - - - - Treads and Landing Material Based on 3" Gap All Sides. r• I I 10" Run I L - - - - - J L _ _ . _ _ _J 90" I I 70" L — — — — — _J L - - - - - -J . , I I I L _ _ , _ _ J L _ _ _ _ - -J 132" 131-1/4" Finish 1- - - - - -1 ',— - - -- - _1 3" Gap 1- - - - - -1 r-- — — — — � 3" Gap I * L - - - - - J L - - - - - J - - i - I I o 0 T 42" .. -J _Y rn Window 1_ 1_ Z Co n ) �; , ---1 No In Floor Heating from 112" to 132" Exampe only not to scale: Down / Upper Floor 18 Risers / 1 IL/ 16 T - 3/8" x 24" Plate RFW _ _ 1- 7 — — — , 1 —1 I Floor to Floor Height as measured 135-3/4" 19-114" I I ___L Bas e eaa.e_ J Red Oxide Prime Only Top Tread Flush tp Finish Floor I I Based on a landing platform design from Strandberg (modification TBD) tL — — — _- __ J r_ — — — — -1 r— — — — — 1 Dimensions Based on a 2" Tread Thickness = I I I I Ground Floor to Finish Landing - 75-7/16" kr r— — - — --- —7 I — — — — 7 Treads and Landing Material Based on 3" Gap All Sides. I I 10" Run L — — — — — J L — — — — — J 90" r— ____ — ___ _1 1,- - ____ ____ - -7 70" L — — — r_ _ J L — - - J . r- - - - - -7 - - - - - I I L — _ J L — — — — — J 132" 131-1/4" Finish r- - - - - -1 'r- - - - - -1 I I L — — — — J L — — — — — J 3" Gap r — — — 7 r— — — - - � 3" Gap I I I I * L — — — — — J L - - - - - J - • I I 0 0 4 7T —_- 42" A t.„----,_v__a! 1 Ell 0 rn m '. l • > aria r Window I_ -- n Y 3 ,- L i