HomeMy WebLinkAboutPermit File 1203 14th Street Willgaire41 CERTIFICATE OF OCCUPANCY This is to certify that the below listed building or structure has been inspected and occupancy is hereby authorized: Description: New Single Family Residence Location: 1203 14th Street Owner: Bill Mendum Constructed by: William Mendum Building Permit #: BLD-2015-0086 Date issued: March 19, 2015 Use Zone: R-4 Dated: December 31, 2015 Authorizing Official: 1 . INSTALLED INSULATION CERTIFICATE *NERAL PLUS Insulation, LLC "A�svldiq�ffnare Efjkiency And area(C,ornjor!For Your IdnoTe 10614 COLLINS ROAD OFFICE (360) 630-6341 SEDRO-WOOLLEY,WA 98281 GM (360)708-3479 We certify that the following residence has been insulated with the following materials: Fiat Ceiling R - 49 Sloped Ceiling R - 38 Exterior Walls R - 23 (BIBS) Floors R— 30 // Address: 1203 14i1'Street,Anacortes,.WA 98221 Certify by Lot#: Date Installed: July 16th,2015 Title General Manager Lyrrce, Groc From: Bill Mendum <maggiministorage@hotmail.com> Sent: Wednesday, January 06, 2016 11:00 AM To: Fyrrce, Groc Subject: Fwd:Insulation Certificates Attachments: Insul Cert for 1203.pdf; ATT00001.htm; Insul Cert for 1205.pdf; ATT00002.htm; Insul Cert for 1207.pdf;ATT00003.htm;Insul Cert for 1209.pdf;ATT00004.htm;Insul Cert for 1211.pdf; ATT00005.htm Here's insulation certs Sent from my iPhone Begin forwarded message: From: "General Plus Insulation, LLC" <gpiinsulation c@hotmail.com> Date: December 29, 2015, 12:18:41 PM PST To: 'Bill Mendum' <maggiministorage a@,hotmail.com> Subject: Insulation Certificates Hello Bill: Sorry for the delay, attached are certificates of insulation for 14th Street, Anacortes, WA. Any questions please do not hesitate to ask. Thank you, Thank you, M&rift Nvvv0 GENERAL PLUS Insulation, LLC "Providing Energy Efficiency and Great Comfort For Your Home" 10614 Collins Rd., Sedro-Woolley,WA 98284 Maria Nuno Office Admin. 360-630-6341 apiinsulation(ahotmail.com From: Bill Mendum [mailto:maggiministorage{a hotmail.com] Sent: Wednesday, December 23, 2015 5:58 PM To: GENERAL PLUS INSULATION Subject: Re: Invoice 2662 from GENERAL PLUS INSULATION, LLC Any chance I could get Insulation certificates for all five units on 14th St. That would be 1205 1207 1209 1211 and 1203 14th St. thank you bill Mendum home builders 1 � f� -��� • am, - .- City of Anacortes Invoice/Permit#: BLD-2015-0086 r - 904 6th Street _ Applied date: 02/25/2015 P.O.Box 547 Issue date: 0 311 912 01 5 1 01 Anacortes, WA 98221-0547 Expire date: 09/14/2016 ,,• . (360) 293-1901 Ctp , Job Address: 1203 14TH ST Permit Type: Single Family Residence Permit ANACORTES WA 98221 Project: APN: Remarks: New single family residence one 5 dwelling unit lot. Owner: BILL MENDUM Contractor: WILLIAM MENDUM Address: PO BOX 1656 Address: PO BOX 1656 ANACORTES WA 98221-6656 ANACORTES WA 98221-6656 Phone: (360) 293-6396 Phone: (360)661-6391 License#: WILLIM*901Q4 General Information: Fees: 1st Floor Square Footage 671 Plan Review Deposit 200.00 Building Valuation 74725 Building Permit Fee 818.75 #of Bathtubs 1 Plan Review Fee 332.19 #of Clothes Dryers 1 Mechanical Permit Fees 78.10 #of Clothes Washers 1 Plumbing Permit Fee 83.00 #of Dishwashers 1 State Building Code Fee 4.50 #of Gas Fireplace 1 Sewer Inspection Fee 50.00 #of Gas Piping 1 Storm Drain GFC-Residential 1,383.17 #of Gas Water Heaters 1 Sewer GFC-Residential 8,828.48 #of Water Piping 1 Park Impact Fee 615.00 #of Hose Bibbs 1 Traffic Impact Fee 900.00 #of Kitchen Sinks 1 Total Calculated: 13,293.19 #of Lavatories 1 Deposits/Receipts: 0.00 #of Range Hoods 1 #of Showers 1 Total Due: 13,293.19 #of Ventilation Fans 1 #of Water Closets 1 C7 --1 -riW —.10 1 ,-t -, cn v, in a= f,.] ;..j i-'• .. 0i VO -r ri .'- F^'- r II' r—, s-- it..rt cc d� o c. 1-'- i0 ,-.. ;_, i t o r-- CD , _ I. z' o. -' 1- t-t Z' ,-i- r71 re fl .. 'it OD 10 F ' x tom' O -n r— THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DA, S, OM l CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMM ICEL : r' HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL PRIDVISLC N 'j OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, r1HE. GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER'r TATh 13k, LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. '-'' r r1 0::t w'. , �.. PJ e...1 i_<. , /\j''.%-77441 f' Icy'' f ( S' -''� `� SIGNATURE OF OW OR AUTHORIZED AGENT ISSUED BY F'' •-' !;.' ... ol pro=--t=`Ft - - - - _ _ • • zu ._ ubilt orks'- - • ?,-= -� - Engineering and Develop lent Services •1 Res-idontial Inspection •. _ Address: I�0-`'.5 — 1.4%. 517 7 e=Dat r z _z•_ i s ne►- L. • c l L1 us, 1)u�.e &1� �. _ - -:"Coactor_• ��l L m. th ii . - - ntr • Inspected by j :. -___- 1. , rP�n>� 1M: �va�1 . • Water Me ox•. S and level to finished grade or backside of sidewalk.elevation_ • • - - i box undamaged_ . " W meter and customer shutoff installed. . - -•• _ No .s, • . Accessibte-no landscape Obstruction_ . . • " QI D ev�ay installation has-drive-over box and rid_ = • !4 .er gate valve intact - • No leaks at connections_ - • ' . ' " - • . ' : ' 2: Curb and•G tter - ' Ill o cracks, damage, graffiti, footprints,finishing,blemishes, or other objectionable C' marks_ - if road frontage improvements: . ' - - ❑ •Expansion joints every l5 feet and at driveways_ f -Concrete has.broom finish.. . . low spot at curb tine, especially at driveway cut_ Maximum grade change in - feet is 74 inch. . • _ 3. Sidewalk • • i. o cracks, damage,graffiti, footprints, finishing blemishes, or other objectionable - • ciA . . arks_ - . . - • . . -, Q ADA compliant-1 percent slope to curb. - . • if road frontage improvements: -' ' . . ❑ ,Expansion joints every 15,feet and at driveways_ - - - . [] - Concrete has broom finish • • - • _ - ffq1A-4. Driveway Approaches Oc e`er ' - No cracks, damage, graffitilfootprints,finishing blemishes, or other.objectionable - [_T 'marks_ • . • • ' 0 ADA cornpllant - • . q4. 5: Streets _ _` . ❑ l\lo-cracks,blemishes: _ • - . if road or alley impro�rernents_ -• . • - - ' fl - Received proctpr and sieve analysis o€ballast,crushed rock,and asphalt - -Received passing;ma erials testing reports for sub--grede,-ballast, crushed - . • " rock• }-and asphalt_ - _ • D Received-tonnage tickets consistent with required thickness-per approved.- . plans_ • . . 6.. Sanitary wer - - • • t ction card'signed off and/or verified in Building Department database_, - 1 As-built record filed in the address fib_ • _ S ew cap(s).instaiied on clean-out(s),_ - . Clean-outs)•set at finished grade. - r 7_ Storm Drainage : - .• � . L.\ ��,‘� _ n `an•card.signed Off.andlor verified in Building Department database. ` • [As-b it-record filed in address file_ - ot blocked or.diverted to adjacent parcel_ . 04, a. Public_Utilities Out of Traveled Way ' 0 . Concrete collars around-City utilities_ - • • , . El Final grading ok . ' • - . - • ElRestored to prior condition or better.• • 9. Landscape:. 3-Ito. �e) - • ❑• .Bonded for completion at later date_ . Verified against approved landscape plan: - - . . . - . ❑ • installation_ ' - - ❑ Type and quantity of plants. - • • - ; ' 0 Sod or seed in place. - - • - ` , - • Q: Root barrier (receipt filed). . 10. Erosion Control pleasures _ •• • MPs rerrioved. • . . - All debris removed. Site clean. •• . ' • ` • Permanent vegetation established_ - • Anacortes,WA Code of Ordinances about:bla 17.28.060 - Minimum setback requirements. Minimum setback requirements in an RH R4 district shall be as follows: A. Front and side yard on a flanking street, ten feet from property lines. If the street is a designated arterial, the distance shall be increased to twenty feet. B. Interior side,five feet or one foot for every five feet of building height, whichever is greater. C. Rear,ten feet or one foot for every four feet of building height, whichever is greater. 1. Where the rear yard does not abut a platted alley, no portion of the primary structure shall extend into the setback area, regardless of the use of that primary structure. One detached accessory structure no larger than one hundred forty-four square feet and twelve feet in height may be placed in a rear yard, or in the rear twenty-five feet of an interior side yard, provided that it is set back a minimum of five feet from the rear property line, and three feet from any side property line. 2. Where the rear yard abuts a platted alley, a detached accessory structure, or that portion of the primary structure used as an accessory structure, may be built in a rear yard up to the alley property line, provided that it is set back a minimum of three feet from any side property line, and is no larger than one thousand square feet and no more than sixteen feet in height. if the accessory structure is a garage, built so that vehicles enter the garage from the alley in a direction substantially perpendicular to the alley, the garage doors shall be set back a minimum of ten feet from the alley property line to allow adequate turning distance for vehicles, 3, One detached accessory structure not exceeding one hundred forty-four square feet shall be permitted without counting as part of the lot coverage. The lot coverage of any additional accessory structures, or of any accessory structure exceeding one hundred forty-four square feet shall count as part of the percentage of lot coverage permitted in this zone. (Ord. 2756 Att. A(part), 2006; Ord. 2614 Att. A(part), 2003; Ord. 2482 Att. A§ 11, 1999; Ord. 2316 (part), 1994) (Ord. 2794, § 1(Att,A), 12-15-2008) 1 of 1 3/16/2015 4:39 P G4zY o� Anacortes Planning& Community Development Dept. Permit Center P.O.Box 547,Anacortes,WA 98221-0547 PH(360) 293-1901 Don Measarner,Building Official,Planning Director FAX(360)293-1938 March 17, 2015 Bill Mendum PO Box 1656 Anacortes, WA 98221 RE: Plan Review notes for the proposed 5 units at 1203-1211 14th St. Please address the following items so I can complete the plan review. £ti l. Show overall lot dimensions on the site plan. .c ,(,(2. Indicate the required side setbacks on the site plan. The East side setback can be 5 feet, but the west must be 5 Y2 feet due to the height of the 2-story building(5 feet for every 5 feet of building height. Zoning code Section 17.28.060, B. i j,,e 1- 3. What type furnace is planned for 1205 146? If gas,must have combustion air from 11 outside U or Please contact me if you have any questions about these notes. Sincerely, Paul Ingalls Plans Examiner City of Anacortes 360-293-1901 Fire-Rated Wood Doors Simpson Door Company Page 1 of 3 FIRE-RATED DOORS FIRE-RATED DOORS Simpson offers thousands of choices for fire-rated doors, including 20-minute fire-rated wood doors and MDF doors with fire ratings-up to 90-minute.And since Simpson fire doors have been designed to match other interior doors,your fire-rated doors will blend seamlessly with all doors in your home. Simpson MDF doors are available with 90-, 60-, 45- and 20-minute fire ratings. Learn more about your design options for these doors here: • Infinity Doors —90-, 60-, 45- and 20-minute fire ratings available • Ovation Doors—90-, 60-,45- and 20-minute fire ratings available • Encore Doors—90-, 60-, 45- and-20-minute fire ratings available 20-minute Wood Fire-Rated Doors Simpson 20-minute fire-rated doors comply with major code requirements for the 20-minute fire safety classification. This classification covers most residential requirements and can also meet commercial requirements for 20-minute.And best of all, Simpson 20-minute fire-rated doors match up perfectly with virtually any Simpson interior panel door, regardless of design or species. • Fire door designs complement Simpson interior door designs for architectural consistency throughout your home • Nearly unlimited design flexibility • Choose from two profiles—traditional ovolo or Shaker • Two panel-types available—3/"flat or 1-7/16"double hip-raised • Order in any size up to 3'6"wide and 8'0"tall • Choose from virtually any wood species • Excellent finishing characteristics • Select decorative options to meet your-design needs • Arched rail components • V-groove raised panels • Product covered—Simpson 20 minute (with hose stream) single-swing stile and rail wood door • Architecture Code-- 08200 Wood and Plastic Doors and Frames file:///C:/Users/Patti/AppData/Local/Temp/Low/SVNQ4MJLhtm 12/30/2015 Fire-Rated Wood Doors ` Simpson Door Company Page 2 of 3 Architecture Subcode -- 08210 Wood Doors o Fire Resistance -- 20 Min wlHose Stream PP Cat B Door o Swing-- Single Swing o Listed or Inspected --LISTED ▪ Report Number-- 3089369C0Q-005; 3137943C0Q-003; 3157209C0Q-005 • These doors have been tested and evaluated for compliance with applicable requirements for the following standards. • UL 10(c) (1998) • UBC 7-2 (1997) o UBC 7-2 (1994) • UL 10(b) (1997) o ASTM E2074 (2000) o NFPA 252 (2003) o CAN/ULC S104 (1980 R1985) I ' I : I F - - I * f i __. • . . 4 i _ . . . . _ [ , 9266 RP 9360 Shaker FP 9255 FP 9366 Shaker FP Shown in poplar Shown in cherry Shown in Douglas fir Shown in maple RAISED PANEL FIRE DOORS Stile 1.7/16'Raised Panel with FR core 9 ,,,,...,„, ,...,,, ..„„tr, „,............ _-, Bulinose / ) / '>''''16 J,11 ��'� Edge Strip .. . ., . ,�,.. � Woad Core 2 Sticking file:///C:/Users/Patti/AppData/LocallTemplLow/SVN04MTl.htm 12/30/2015 Fire-Rated Wood Doors I Simpson Door Company Page 3 of 3 FLAT PANEL FIRE DOORS SHAKER FIAT PANEL FIRE DOORS fit! g/with F Pa CCore ____:;57-:.\\ 1 ifil " F_/.7-'--,:. ,,-. . ,,. N , Edge Strip l&ewe -•;;:': \ /. -,- ....• - Ai1IJ4iiL -` Wood Core Shaker Sticking Available Options ' FII WHERE TO BUY FIND A DOOR liall file:///C:/Users/Patti/AppData/Local/Temp/Low/SVNQ4MJI.htm 12/30/2015 Q Cityof Anacortes Invoice/Permit#: BLD-2015-0256 904 6th Street Applied date: 06/02/2015 P.O.Box 547 Anacortes, WA 98221-0547 Issue date: 06/10/2015 (360) 293-1901 Expire date: 1 210 6/2 0 1 6 Job Address: 1203 14TH ST Permit Type: Fire Sprinkler Permit ANACORTES WA 98221 Project: APN: Remarks: Install fire sprinkler system info new residential building • Owner: BILL MENDUM Contractor: X-FIRE Address: PO BOX 1656 Address: 1511 KENTUCKY ST ANACORTES WA 98221-6656 BELLINGHAM WA 98229-4718 Phone: (360) 293-6396 Phone: (360) 715-8088 License#: XFIRE**961 PN General Information: Fees: Building Valuation 2258 Plan Review Fee 54.11 State Building Code Fee 4.50 Building Permit Fee 83.25 Total Calculated: 141.86 Deposits/Receipts: 0,00 Total Due: 141.86 01 -., l 4 Z, r .. • �-,, r•.:r r rr (iI I11 Q tr f;i I.-. `.. I'ti i;q 7_J.'. :-r ilti. rr) ir. i i i ik a. '.1 J l fll THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED 1S NOT COMMENCED WITHIN 180 DAYS, OIL I ' CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMM10EQ:,; I:F� HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL PROVISIONS. OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR MOT, IT:HW GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER, 'TAT7 :„O b LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION, SIGNATURE OF OWNER OR AUTHORIZED AGENT SSUED BY '— :: y - --_-t .. . - -- .iceMP Fire SprinkleriAlarm Permit plication " d5-7-3, City of Anacortes Building Department • 904 6th Street -�- Anacortes, Washington Phone: 360 293-1901 Fax: (360 293-1938 r r f : I 'i L Ali iii ilkik: AL li V ds414 1 ii • • LA] :10 Site address: Parcel No.: , • Lot: Block: Addition: -2 Owner , Owners Name: ti\\ �w 4 .-N _Phone No,: 6O $ M - i Address: iC.% jp Sfate:Mi ' Zip, . ____� r Tenant Tenant's Name: Phone No : Contractor information Contractor: X- C 4 Phone No.: 344 -7( 'ece ' • Mailing Address: 601 Kt f1t 1C.VN ' Q„Acre,eir . State'. VV Zip: 41 aa _ t State Sprinkler Certificate Level and License No.: cii2I, PN __Exp. Date:114081 General information • . . Please Check: Fire Alarm ❑ Fire Sprinkler . Modify Existing System ❑ Install New System r Underground Fire Line D Value of Project (labor and materials) $_ . . , „ J • Required Submittals Three(3): Scaled construction drawings showing•t#re following elements along with their dimensions z 1. Floor plan indicating the location of devices and appliance, end of the line devices, ; conduit wire runs, conduit size and number and size of devices. The zone Indication shall be placed adjacent to the appropriate end of the line device, 2. interior, exterior and underground fire alarmisprinkler components • 3. Transition from exterior to interior. • 4. Manual fire alarms and strobes (including installation height) ' 5. Fire alarm control panel location, riser locations and control valves • - 6. Door hold-open device 7. Heat and smoke detectors (identify type) duct detectors • 8. System Calculations and manufacturers information on system components 9. Fire Sprinkler tamper • 10, Water flow and control valves 11. Site Plan,(S ow FOC, PIV cations) 'z Signature: �J� Date: 5/31//5- Applicant or fh'aner 1 �, l UpdCcd m Novcber 4, 2009 G!TY CA- NACU RT E 'PH -Mr-�NF7 r Li E c ' . APPROVED PLANS :Miff NO-4/a: �•`r Ess• iliPPPICNED t3Y, -. '�._; ;IBJECI 10 FIELD uN PECT1O . CA/ERSIt.* s'' # VInLATPON OF nlIF IS Nr.T INC[ LJDr Fire Sprinkler System Calculations X-Fire Security 1511 Kentucky St, Bellingham, WA 98229 Job No: L-2573 Job Name: 1203 14th Street Residence Building Type Single Family Residence Location: 1203 14th St,Anacortes WA System Type: NFPA 13D 2010 a WASKINGTON STATE CERTIFICATE OF COMPETENCY e! FIRE PROTECTION SPRINKLER SYSTEMS Rodney L. Durham 8511-0705-A Level 1 X--illtrh, ./ N �� !Expires P a to 12/3.1/15 a,umunvss gem Ds!vx,ai ire mex,an c®ear ens-r M.mow min Designed by X-Fire Security- 1511 Kentucky St, Bellingham, WA 98229 - 360.715.8088 L-2573 1203 14th Street Residence -Two Head Calculation -(H.5 H.6) Page 2 of 5 Final Calculations -Summary Wednesday, May 27, 2015 Hydraulic Design Information Sheet _ Job Name 1203 14th Street Residence Opened Date 5/27/2015 Location 1203 14th St,Anacortes WA Job No L-2573 Building Type Single Family Residence Ceiling Height (ft) 9 Calculated By Rod Durham Construction Combustible Occupancy Residential System Design Type of Calculation NFPA 13D 2010 Listed Flow at Start Point (gpm) 13.000 System Type Wet Listed Pressure at Start Point (ps 9.100 Sprinkler Make Reliable Maximum Listed Spacing (ft) 16 Sprinkler Model RFC43 Domestic Flow(gpm) 0.000 Sprinkler Size (in) 0.50 Elevation at Highest Outlet (ft) 112 Sprinkler K-Factor 4.3 Temp. Rating (°F) 165 Coverage Area (ft2) 256 Listed Flow(gpm) 13.000 Calculation Summary Flowing Sprinkler Heads H.5 H.6 Flow Required (gpm) 26.000 Pressure Required (psi) 37.924 At Reference Point METER Overhead C-Factor Used 150 Underground C-Factor Used 150 Water Supply Water Flow Test: Static Pressur 60.000 Residual Pres 52.500 Flow(gpm) 30.000 Elevation (ft) 97 Manifold & Water Flow Switch Additional Pressure Loss (psi) 4.60 L-2573 1203 14th Street Residence-Two Head Calculation - (H.5 H.6) Page 3 of 5 Final Calculations -Water Supply Curve Wednesday, May 27, 2015 100 90 - _ 80 70 - - 60 ek, (n d 50 112 N N o- 40 - - 30 - - 20 10 - - 0 - 10 202530 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Flow(N"1.85)GPM • • Demand Curve Required Pressure: 37.924 psi @ 26.000 gpm Required Flow: 26.000 gpm o O Supply Curve Static Pressure: 60.000 psi @ 0.000 gpm Residual Pressure: 52.500 psi © 30.000 gpm WASHINGTON STATE Available Flow: 30.000 gpm CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS >C • Pressure Cushion Rodney L. Durham Available Pressure: 54.244 psi @ 26.000 gpm 8511-0705-A Level 1 Pressure Cushion: 16.321 psi X-Fire XFIRE""96 •N 6 idpr `,ii-Vaatear •,p-isnt - Sseem U, U,�s P:n rm®•- 'Mrm w.-ras; i L-2573 1203 14th Street Residence -Two Head Calculation - (H.5 H.6) Page 4 of 5 Final Calculations - Nodes Wednesday, May 27, 2015 Actual Actual Elevation Pressure Flow Node No. (ft) (psi) (gpm) Model-Coverage(DxW)-Temperature S.0 102.0 28.398 0.000 SOURCE H.1 109.0 16.563 0.000 RFC43-1212-165 D.T.1 109.0 17.203 0.000 Rehau PEX 0.75in Dom Tee H.2 109.0 18.945 0.000 RFC43-1212-165 H.3 109.0 20.124 0.000 RFC43-1212-165 H.4 109.0 22.563 0.000 RFC43-1616-165 H.5 112.0 9.176 13.000 RFC43-1616-165 H.6 112.0 9.100 13.000 RFC43-1616-165 H.7 112.0 18.045 0.000 RFC43-1616-165 FT.6 112.0 12.601 0.000 Rehau PEX 0.75in Sprinkler Tee FT.5 112.0 12.677 0.000 Rehau PEX 0.75in Sprinkler Tee 11 L-2573 1203 14th Street Residence -Two Head Calculation - H.5 H.6 Pa e 5 of 5 Final Calculations -Pipes Wednesday, May 27, 2015 Pipe# Hyd. Qa Dia. Fitting Pipe Pt Notes 1 Ref. C-Factor Fittings Pe Point Qt Pf1UL +PrLoss, Total Pf p0 FT.6 11.158 0.681 10.102 16.563 to 150 1 R1 H 1.000 1.299 Vel = -9.8 H.1 -11.158 0.2399 0.00 11.102 2.663 sup° METE 0.000 1.380 75.000 28.398 i to 150 MNF 0.000 2.166 Vel = 5.6 1 S.0 26.000 0.0368 4.60 75.000 2.760 p1 H.1 -11.158 0.681 1.670 17.203 to 150 1 R 1 H 1.000 0.000 Vel = -9.8 D.T.1 -11.158 0.2399 0.00 2.670 . 0.640 p2 D.T.1 0.000 0.681 6.260 18.945 to 150 1 H1 R 1.000 0.000 Vel = -9.8 H.2 -11.158 0.2399 0.00 7.260 1.741 p3 H.2 0.000 0.681 3.917 20.124 to 150 2H 1.000 0.000 Vel =-9.8 H.3 -11.158 0.2399 0.00 4.917 1.179 p4 H.3 0.000 0.681 9.170 22.563 to 150 2H 1.000 0.000 Vel=-9.8 1 H.4 -11.158 0.2399 0.00 10.170 2.439 _ p5 H.4 0.000 0.681 11.186 28.398 to 150 1 H 0.500 3.032 Vel = -9.8 S.0 -11.158 0.2399 0.00 11.686 2.803 p8 S.0 -11.158 0.681 14.309 18.045 to 150 1H 0.500 4.331 Vel = 13,1 H.7 14.842 0.4067 0.00 14.809 6.022 p7 H.7 0.000 0.681 12.201 12.677 to 150 1 H 1 R 1.000 0.000 Vel= 13.1 FT.5 14.842 0.4067 0.00 13.201 5.368 p6 FT.5 -1.842 0.681 7.922 12.601 to 150 2R 1.000 0.000 Vel = 1.6 FT.6 1.842 0.0086 0.00 8.922 0.076 _ hp6 H.6 0.000 0.681 0.000 12.601 to 150 1 H 1 B 11.000 0.000 Vel = 11.5 FT.6 13.000 0.3182 0.00 11.000 0.000 hp5 H.5 0.000 0.681 0.000 12.677 to 150 1H1B 11.000 0.000 Vel = 11.5 FT.5 13.000 0.3182 0.00 11.000 0.000 Bulletin 006 Rev,D Rel iabld Model RFC43 (SIN RA0612) co Model RFC49 (SIN RA0616) Flat Concealed Residential Sprinklerscp -- a A Concealed Residential l Sprinkler engineered for a ` minimum design density :11; of 0.05 gpm{ft2 with low GPM requirements. f, Features 1 . Very low water flow requirements. • • 2. %" (13mm) Total adjustment. ' • 3. Thread-On/Thread-Off or Push-On/Thread Off cover attachment option. 4. Smooth aesthetic ceiling profile. • 5. Available in brass, chrome and sir*441".... black plated or painted finishes, . Listings & Approval r: 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) 2. NYC MEA 258-93-E UL Listing. Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC43 and RFC49 Concealed Residential Sprinklers The RFC43 and RFC49 are UL Listed Residential Sprinklers are fast response residential fusible solder link automatic to be installed in the residential portions of any occupancy in sprinklers. Residential sprinklers differ from standard accordance with NFFA 13, 13R, & 13D. sprinklers primarily in their response time and water The RFC43 and RFC49 can reduce the need for precise distribution patterns. cutting of drop nipples_ The threaded cover plate assembly Model RFC43 and RFC49 sprinklers discharge water in a can be adjusted without tools to fit accurately against the hemispherical pattern below the sprinkler deflector, ceiling. The fire protection system need not be shut down to Residential distribution patterns are higher and generally adjust or remove the cover plate assembly. contain a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge Application and Installation pattern required for residential sprinklers has demonstrated, The RFC43 and RFC49, for residential installations, use a in fire testing, an ability for controlling residential fires, and 165°F(74°C)fusible solder link in a tuning fork style sprinkler thereby providing significant evacuation time for occupants, frame with a drop-down deflector. This assembly is recessed The RFC43 and RFC49 Sprinklers provide the best form of into the ceiling and concealed by a flat cover plate. The cover fire protection by combining an attractive appearance and plate is attached to the skirt, using 135°F (57°C) ordinary '/z" (13mm)of cover adjustment for ease of installation. The temperature classification solder. When the ceiling small diameter cover plate is easily and positively attached temperature rises,the solder holding the cover plate releases and blends into the ceiling,concealing the most dependable the cover allowing the deflector to drop into position and fire protection available, an automatic sprinkler system. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 exposing the sprinkler inside to ceiling temperature. The should be taken to prevent damage to the sprinkler. DO NOT subsequent operation of the solder link opens the waterway WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP and causes the deflector to drop into position to distribute the ASSEMBLY. MODEL RFC43 AND RFC49 CONCEALED discharging water in a hemispherical pattern below the SPRINKLERS MUST BE INSTALLED ONLY WITH 135°F sprinkler deflector, Any adjustment of thread engagement RATED COVERS. between the cover plate and cup will assure that the Cover assemblies provide up to y" (13mm) of drop-down deflector is properly located below the ceiling. adjustment. Turn the cover clockwise until the flange is in The residential distribution pattern contains a finer droplet size contact with the ceiling. For the push-on/thread-off option, than a standard sprinkler, and the pattern produces the cover assembly is pushed onto the cup and final significantly higher wall wetting. adjustment is made by turning the cover clockwise until the After a 2 5/8 inch diameter hole is cut in the ceiling, the skirt flange makes full contact with the ceiling. Cover sprinkler is to be installed with the Model FC Wrench. When removal requires turning in the counter-clockwise direction. installing a sprinkler, the wrench is first positioned into the In ceilings that have a plenum space above the sprinkler, sprinkler/cup assembly and around the hexagonal body of the plenum space may have neutral or negative the sprinkler frame. The Wrench must bottom out against the pressurization but must not be positively pressurized. Inspect cup in order to ensure proper, safe installation. The sprinkler all sprinklers after installation to ensure that the gap between is then tightened into the pipe fitting. When inserting or the cover plate and ceiling and the 4 slots in the cup are ail removing the wrench from the sprinkler/cup assembly, care open and free from any air flow impediment. Temperature Rating Sprinkler Cover Plate Max,Ambient Temp. 165`F/74`C 135''F/57"C 100'F/38'C Installation Data: RFC43 (SIN RA0612) Minimum Required Thread Size K Sprinkler Maximum Minimum Sprinkler Discharge inch(mm) Factor Spacing Distance Distance between ft.(m) to Wall ft.(m) sprinklers,ft.(m) Flow Press. gpm(Lpm) psi (bar) 'h"(15rnrn) 4.3 12 x 12(3,6x3.6) 6(1.83) 8(2.43) 12(45) 7,8(0.54) 1/2"(15mm) 4.3 14 x 14(4.3x4.3) 7(2.13 8(2.43) 13(49) 9.1 (0.63) 1/2"(15mm) 1.3 16 x 16(4,9x4.9) 8(2.43) 8(2.43) 13(49) 9.1 (0.63) /2"(15mm) 4,3 18 x 18(5.5x5.5) 9(2,74) 8(2,43) 18(68) 17.5(1.21) /"(15mm) 4.3 20 x 20(6.Ox6.0) 10(3.05) 8(2.43) 21 (79) 23,8(1.64) Note: 1 bar= 100 Kpa Installation Data: RFC49 (RA0616) Minimum Required Thread Size K Sprinkler Maximum Minimum Sprinkler Discharge inch(mm) Factor Spacing Distance Distance between — ft.(m) to Wall ft. (m) sprinklers,ft, (m) Flow Press. gpm (Lpm) psi(bar) '/a"(15mm) 4.9 12 x 12(3.6x3,6) 6(1.83) 8(2,43) 13(49) 7.0(0.48) /s"(15mm) 4.9 14 x 14(4.3x4.3) 7(2.13) 8(2,43) 13(49 7.0(0.48) /"(15mm) 4.9 16 x 16(4.9x4.9) 8(2.43) 8(2.43 13(49) 7.0 0.48 1/2"(15mm) 4.9 18 x 18(5.5x5.5) 9(2.74) 8(2,43) 17(64.3) 12.0(0.83) 1/2"(15mm) 4.9 20 x 20(6.0x6.3) 10(3.05) 8(2.43) 20(75.7) 16.7(1.14) Note: 1 her= 10D Kpa FOR SLOPED CEILING APPLICATIONS SEE RASCO BULLETIN 035. 2, 1 Maintenance Model RFC43 and RFC49 Concealed Sprinklers should be 135°F(57°C). Cover plate assembly shall consist of a brass inspected quarterly and the sprinkler system maintained in cover plate and copper alloy retainer flange allowing a '/" accordance with NFPA 25. Do not clean sprinklers with soap cover plate adjustment. Any secure engagement between and water, ammonia or any other cleaning fluids. Remove the cover plate and the cup will assure that the drop-down dust by using a soft brush or gentle vacuuming. Remove any deflector is properly located below the ceiling. A plastic sprinkler cover plate assembly which has been painted(other protective cap shall be provided and factory installed inside than factory applied) or damaged in any way. A stock of the sprinkler cup to protect the drop-down sprinkler deflector spare sprinklers should be maintained to allow quick from damage,which could occur during construction before replacement of damaged or operated sprinklers. Prior to the cover plate is installed. Standard cover finish: [Chrome] installation, sprinklers should be maintained in the original [White][Specialty—specify]. Residential concealed sprinklers cartons and packaging until used to minimize the potential for shall be Reliable Model RFC43, SIN RA0612(Bulletin 006)or damage to sprinklers that would cause improper operation or Model RFC49, SIN RA0616(Bulletin 006). non-operation, Model RFC43 and RFC49 Residential Ordering Information Cover date Finishes'1) Concealed Sprinkler Specification Specify: Standard Finishes Sprinklers shall be cULus Listed low flow residential 1. Sprinkler Model Chrome concealed sprinklers with drop-down deflector and 2. Cover Plate Finish White adjustable flat cover plate engineered for a minimum design 3. Thread-On or density of 0.05 gprr,/ft2. Sprinkler frame and deflector shall be push do Feature Special Application of bronze frame construction having a 1/" NPT thread. Finishes Thermal element shall consist of an approved black-painted Bright Brass beryllium-nickel fusible solder link with symmetric lever ack Hating mechanism, maintaining a Teflon-coated Belleville spring washer and machined brass cap water seal assembly Back Paint containing no plastic parts, Sprinkler K-factor shall be nominal oft white 4.3(62.4), having a 7/16"orifice. Temperature rating shall be Satin Chrome Ordinary 165°F (74°C); cover plate temperature rating to be other colors and finishes available. Consult lactory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. 1" x 1/2" REDUCING l TEE OR ELBOW ii ____ ,___.4 lib, r- 1 2 " (66.7mm] DIA, IMF" A" [58,7mm] DIA — HOLE IN CEILING 1. J CUP 2" [50,8mm] A/AX, ;* i FACE OF FITTING !1 TO FACE OF CEILING 0ff/ENS/ON 4+4 :.�.> CEILING _" (12.7mm] VAX. T l COVER ADJUST!/ENT " DIA, '3/16 3 — COVER PLATE (84.1 mm] [4,Bmm] LH " A5SEBLY SPRINKLER i' 1 --- COVER PLATE: 1/2" [12.7mm] ADJUSTMENT ,...._-- I 3. 1 EHHB Product • Submittal Product: RAUPEX(2)Non-Barrier Pipe Date: 19-August-05 Submittal#: 100RAUPEXNB Category; RAUPEX Pipes Page: 1 of: 1 I REHAJ RAUPEX Non- arrier Pipe A I a - ff8 --- Nominal Article No. A OD'In.(mm) 13 ID°in.(mm) C Wall t2 In. Weight Capacity Diameter (mm) lb/ft(kg/m) Gal*/foot film) _ 261683 318" 0.500(12.7) 0.360(9..1) 0.070(1.8) 0.04(0.06) 0.0050(0.0624) 261026 1/2" 0.625(15.9) 0.485(12.3) 1 0.070(1.8) 0.05(0.08) 0.0098(0.1222) 261046" 314" 0.875(22.2) 0.681 (E7,3) 0-eri_2.5) 0.10(0.16) _ 0.0189(0 2356) • 261066* _ 1" 1.125(28.6) 0.875(22.2) 0.125(3.2) 0.17(0.26) 0.0316(0.3939) 261086 1 1(4" 1.375(34.9) 1.069(27.2) 0.153/3.9) 0.25(0.37) 0.0467(0.5827) 261106 1 1/2" 1.625(41.3) 1.263(32.1) 0.181 (4.6) 0.350.52) 0.0650(0.8118) 138331 2" 2.125 54.0 1,653 42.0 0.236(6.0) 0,60(0.90) 0.1114(1.3906) 1-Average OD from ASTM F 876 2.Minimum Waif t from ASTM F 876 3-tD is calculated based on OD(1) and Walt I(2) 'US Galion TECHNICAL DESCRIPTION Specification English Si Standard Specification English SI Standard i Minimum 4194 4355 26-3 ASTM F 876 Density 58 lb/ft' 925 kg/rn' DIN 53479 Tensile @ 68°F psi @0 0lCm2 Degree of ASTM F 876 Strength 2610-2900 psi 18-20 Nimm2 DIN 53455 Cross-Linking 70-89% 70-89% DIN 16892 @ 176°F @ 80°C Thermal 0.24 0.41 DIN 52612 IZOD Impact No Break No Break DIN 53453 Conductivity BTU/(hr ft°F) w!(m°K) Res. Linear Exp. 9,33 x 10-4 inlfl°F @ 68°F 0,14 mml(m°C)@ 20°C DIN 42328 Temperature _40°F to 200°F -40°C to 93°C N/A 1.33 x 10-3 in/ft°F @ 212°F 0.2 mmi(m°C)@ 100°C Working Range 87,000-130,500 psi 600-900 Nlmm2 Roughness e=0.00028 in e=0.007 mm N/A Modulus of @ 68°F @ 20°C Max.Short- 150 psig @ 1035 kPa Elasticity DIN 53457 term Exposure 210°F(48 Fr) 99°C(48 Fr)r) ASTM F 876 43,500-58,000 psi 300-400 Nlmm2 @176°F @ 80°C UV Resistance 15 days 15 days PPI TN-33 FUNCTIONAL DESCRIPTION RAUPEX Non-Barrier pipe is manufactured using REHAU's high-pressure peroxide method for cross-linked polyethylene (Engel method, PEXa),Ail RAUPEX Non-Barrier pipe meets or exceeds the requirements of ASTM F 876,F 877,CSA B 137.5 and PP4 TR-3,and is certified to NSF Standards 14/61. RAUPEX Non-Barrier pipe also meets the requirements of NSF P 171 and ASTM F 2023 for chlorine resistance. RAUPEX Non-Barrier pipe is produced In REHAU's ISO 9001 certified manufacturing facilities. `These pipes are certified by UL to UL 1821 and by ULC to ULC-ORD C199P for NFPA 13D fire protection applications, RAUPEX Non-Barrier pipe is rated for continuous operation of 160 psi @ 73.4°F(1105 kPa @ 23°C), 130 psi @ 120°F(900 kPa @ 49°C), 100 psi @ 180°F(690 kPa @ 82.2°C)and 80 psi @ 200°F(550 kPa @ 93.3°C). it is compatible with brass crimp ring fittings certified to ASTM F 1807, RAUPEX compression nut fittings, and EVERLOC compression-sleeve fittings certified to ASTM F 2080 and CSA B 137.5. Use of RAUPEX Non-Barrier pipe in heating systems requires corrosion protection and/or isolation by using a heat exchanger or non-ferrous components throughout the system. The Information contained herein is believed to he reliable,but Ile representations,guarantees,or warranties of any kind are made as to its accuracy.suitability for particular applications or the results to be attained therefrom. Before using,the user shall determine suitability of the information for user's Intended use and shall assume all risk and liability in connection therewllh. installation shall comply with local codes where applicable. To the extent permitted by law,REHAU DISCLAIMS ALL WARRANTIES,EXPRESS OR IMPLIED,INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE, I POLYETHYLENE CTS PIPE FASTENER • Itemli Submitted 555 series Tube Talon'., Job Name SPECIFICATION Location Sioux Chief 555 Series Tube Talon'CTS pipe fasteners shall be used where Engineer necessary to secure CTS tube in piping systems. Fastener shall be 100% Contractor corrosion proof and U.V. resistant. Fastener shall be impact resistant to 0°F, po# TAG and be able to withstand continuous temperatures up to 160°F. Fastener shall have a preleaded nail,which shall be rust resistant, zinc plated yellow irradite. Preloaded nail shall have a continuous ring shank to provide a more permanent installation. Fastener shall snap onto CTS tube for easy installation,and shall allow for expansion and contraction of tube with less • noise. Fastener shall be designed to avoid tube damage if nail is over driven. MATERIALS „xi fastener body: High density black polyethylene; 100%corrosion proof; U.V. resistant; impact resistant to 0°F; max temp: 1.60°F continuous. nail: Rust resistant; zinc-plated yellow irradite; continuous ring shank, MAXIMUM LOAD RATING 555-1:3 lbs. 555-2 555-2:5 lbs. 555-3: 8 lbs. 555-4: 12 lbs. APPROVED USES Manufacturer has approved the Tube Talon for use with: copper tube,CPVC tube, PEX/PB tube, CSST lines,flexible gas tubing,plastic/steel conduit, low voltage DataCom cable. INSTALLATION Manufacturer suggests the Tube Talon be installed in alternating directions Lw.. (so that the fastener's nail is on alternating sides of the tube being fastened)to ensure secure installation. Install fasteners at intervals described in local plumbing code for the type of pipe or tube being fastened. ® To install IPS tube, use the next larger size fastener, e.g. if you are fastening I ® s 1/2" IPS tube, use a 3/4"fastener. 1 DIMENSIONS: 555-1 555-2 555-3 555-4 A A: width 0.848" 1.125' 1.375" 1.6875" r B: height 0.735' 0.875" 1.1875" 1,4375" C: depth 0.375" 0.375" 0.4375" 0.5" D: nail length 1.625" 1.625" 2.125" 2.375" 0 c E: hook height 0.468" 0.5625" 0.75" 0.9063" F. width to center of tube 0,5" 0.6563" 0.75" 0.9375" Create Item Number 555-A e.g.555-3=Tube Talon for°G"CTS piping A TUBE SIZE o 1 3/a"CTS oo 2 1/2"CTS ❑ 3 3/4"CTS ❑ 4 1"CTS Sioux Chief Sioux Chief iulanufacturing Company •tei:1-800-821-3944 •www.slouxchief.com • fax:1-800-758-5950 14-08 • Avoid contact with eyes. Splash-proof chemical goggles are recommended. • Review the Material Safety Data Sheet (MSDS) and the important product information provided on the label for Spears'FS-5 One-Step Low VOC Solvent Cement. Failure to follow the above recommendations could result in death or serious personal injury. Listings, Approvals, Application & Use Spe it Flan'Guard' Fire Sprinkler Products are fully tested and approved for use in wet pipe fire sprinkler systems by Underwriters Laboratories Inc., FM Global, and the Loss Prevention Certification Board. Spears° FlameGuard® CPVC Fire Sprinkler Products are approved for use in low pressure dry pipe or pre-action systems by Underwriters Laboratories Inc. Spears° FlameGuard® CPVC Fire Sprinkler Products are listed by NSF® International for use in potable water systems. For specific listing information not covered in this manual concerning Factory Mutual,The Loss Prevention Certification Board or NSF® International, please contact your nearest Spears°Regional Distribution Center. NOTICE: National Fire Protection Association (NFPA) Standards 13, 13R, and 13D must be referenced for design and installation requirements in conjunction with this manual and all local codes, CAUTION: Spears° FlameGuard® CPVC Fire Sprinkler Products are NOT listed for outdoor applications. Outdoor installation could result in product failure and property damage and will not be covered under the Spears° FlameGuard®CPVC Fire Sprinkler Products warranty. CAUTION: Spears° FlameGuard® CPVC Fire Sprinkler Products are to be used in wet pipe systems only, except as provided for dry pipe or pre-action systems in this manual. A wet pipe system is one that contains water and is connected to a water supply system so that the water will discharge immediately when the sprinkler is opened. A low pressure dry pipe or pre- action system is a piping system containing air or nitrogen under pressure that is release with the opening of a sprinkler which activates a special dry pipe valve allowing water to flow into the piping system and to the open sprinkler. WARNING: Spears° FlameGuard°CPVC Fire Sprinkler Products must never be used for distribution of compressed air or other gases except as provided for under Low Pressure Dry Pipe and Pre-action Systems specified in this manual. Failure to follow this warning could result in product failure, property damage and severe personal injury or death. Light Hazard Occupancies Spears°FlameGuard°CPVC Fire Sprinkler Products are UL Listed for use in Light Hazard Occupancies, as defined in the NFPA 13. In accordance with NFPA 13,2002 Edition paragraph 6.3.6,2,"Pipe or tube listed for light hazard occupancies shall be permitted to be installed in ordinary hazard rooms of otherwise light hazard occupancies where the room does not exceed 400 square feet". NOTICE: Local jurisdictions must approve of this exception. Residential Occupancies Spears°FlameGuard°CPVC Fire Sprinkler Products are UL Listed for use in: Residential occupancies up to and including four stories in height, as defined in NFPA 13R. Residential occupancies, as defined in the Standard for the Installation of Sprinkler Systems in One and Two Family Dwellings and Manufactured Homes, NFPA 13D, PG-3-1010 ©2010 Spears'Manufacturing Company Page 7 FOR SMALL PIPE p poyfER VANE TYPE WATERFLOW ALARM SWITCH • The Symbol of Protection WITH RETARD AND GLUE-IN UNION CUL,UL and CSFM Listed,CE Marked,NYMEAACCEPTED Service Pressure: Up to 175 PSI(12,07 BAR) -' Minimum Flow Rate for Alarm: 8-I0 GPM(30-38 I.PM) • Maximum Surge: I S FPS(5,5 tills) Enclosure: Die-cast,red powdercoat finish No,1113555:Cover held in place with tamper resistant screws No. 1113600- Tamper:Cover incorporates micro-switch. Clover Tamper: Activated by cover removal. Cover Tamper Switch Contacts: One set SPOT,Rated at 250VAC. • Cover Tamper Switch Terminations: 8"22AWG wire leads. Contact Ratings: Two sets of SPOT(Form C) 15.0 Amps at 125/250 VAC 2.0 Amps al;to VDC Conduit Entrances: Two knockouts provided for 1/2"conduit. Usage: Listed CPVC plastic piping systems manufactured by Central Sprinkler Corp.,Grinnell Sprinkler Corp.,Spears Manufacturing Co.,and 1PEX(Scepter). Fits pipe sizes- 1", 1-1/4", 1-112"and 2" US Patent No.6,4-71,255 Environmental Specifications: • Suitable for indoor or outdoor use with factory installed gasket Stock No. 1113555 and die-cast housing. 1113600 W/TSK • For NEMA 4/1P55 rated enclosure-use with appropriate conduit Service use: fitting and/or plugs. Automatic Sprinkler NFPA-13 Temperature range:40°F to 120°F(4,5°C to 49°CI One'or two Family dwelling NFPA-13D Caution: This device is not intended for applications in explosive Residential occupancy up to four stories 'NEPA-13R environments. National Fire Alarm Code NFPA-72 The Model VSR-SFG is avanetypewaterflow switch for use on wet sprinkler operation of the VSR-SFC.i. See Fig. I.) Wait 2 to 4 hours to allow the systems using CPVC plastic fittings manufactured by Central Sprinkler glue to dry before attaching the VSR-SFG to the I"male fitting. Select the Corp., Grinnell Sprinkler Corp., Spears Manufacturing Co., and !PfiX proper paddle for the pipe size and type of TEE used.See Fig.3 and Fig.5 (Scepter)that use 1", I-1/4", 1-1/2"or 2"pipe sizes. It is equipped with a for instructions on how to change paddle.Verify that the o-ring is properly union to accommodate installation in confined spaces. positioned in its groove.'land tighten the nut on the union after orienting the. The unit contains Iwo single pole double throw snap action switches and an device in the appropriate direction to detect waterllow as shown in Fig.2. adjustable,instantly recycling pneumatic retard.The switches are actuated CAUTION:Do nut over-tighten the union not,hand tighten only! • when a flow of 8-101 gallons per minute(30-18 liters per minute)or more The vane mull not rub the inside of lire TEE or bind i,1 any way.The stem occurs downstream oldie device,The flow condition must exist fora period should move freely when operated by hand. of time necessary to overcome the selected retard period. INSPECTION AND TESTING:Check the operation of the unit by opening INSTALLATION: These devices maybe mounted on horizontal or vertical the inspector's test valve at the end of the sprinkler line or the drain and test pipe.On horizontal pipe they should be installed on the top side of the pipe connection,Wan inspector's test valve is not provided. where they will be accessible.The units should not be installed within 6"(15 cm)ofa valve,drain or fitting which changes the direction of the waterfiow. If:here are no provisions for testing the operation of the flow detection The unit has a I"male fitting,for gluing into a CPVC plastic TEE. device on the system..application of the VSR-SFG is not recommended or advisable. Loosen the union nut and separate the 1"male fitting front the VSR-SFG. Glue the I" male fitting into the TEE following the.TEE manufacturer's frequency of the inspection and testing and its associated protective instructions for preparation and gluing of CPVC;piping systems. (NOTE; monitoring system should be in accordance with the applicable NFPA The,- I" male fitting must buttons out on the stop of the '1"1 1. for proper Codes and Standards and/or authority having jurisdiction (manufacturer recommends quarterly or more frequently). Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800.325-3936lCanada 188-882-1833 • www.pouersignal.cont I'RtN I'E❑IN USA MKT.111100009-REV P PAGE I OF 2 • MFG.45401062_I I los SENSOR*Th .ce4 14 `° r *141 p Outdoor Selectable- lit Output Horns, Strobes, ! . e and Horn Strobes for Wall Applications • SpectrAlert°Advance outdoor audible visible products S �� �.o , �=PECT � rtIL are rich with features that cut installation times and "`"=''� 5 maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, •Weatherproof per NEMA 4X,IP56 strobes,and horn strobes in the industry.With white or red plastic Listed to UL 1638(strobe)and UL 464(horn) housings,wall or ceiling mounting options,and plain or FIRE-printed • devices,SpectrAlert Advance can meet virtually any application •Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151°F. •Field-selectable candela settings:15,15/75,30,75,95,110,115, 135, 150, 177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes,and •Automatic selection of 1 2-or 24-volt operation at 15 and 15/75 horn strobes for wall applications include a variety of features that candela increase application flexibility and simplify installation.First,field- Rotary switch for horn tone and three volume selections selectable settings,including candela,automatic selection of 12-or • 24-volt operation,horn tones,and three volume options enable •Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. •Rated from—40°F to 151°F • •Universal mounting plate with an onboard shorting spring that Next,SpectrAlert Advance devices use a universal mounting plate tests wiring continuity before devices are installed for both wall and ceiling applications.This mounting plate includes Plug-in design with minimal intrusion into the back box an onboard shorting spring that ensures wiring continuity before • devices are installed,so installers can verify proper wiring without •Tamper-resistant construction mounting the devices and exposing them to potential construction damage.Once the plates are mounted,all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults, Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)[hat accommodate in-and- Agency Listings _ out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING " corrosion.Knock-outs located on the back eliminate the need to drill holes for screw-in mounting.Plastic and metal weatherproof back ME boxes come with 3/4-inch top and bottom conduit entries and'/4-inch LISTED •••" �soo-iai3 ia�(au °or>nr,6es) approved r2`-'^"'"9(homsirohes, knock outs at the back.A screw in NPT plug with an 0-ring gasket WI I lchimes,hMncnnheL horn,l APPROVED PP enure wabes} sin ioi¢dnnrenr,Alert crnb^s, 1,1;3•7> MFA457-04-F 7135.15,1.1N Thor ns,rhIr ) for a watertight seal is included with each back box. 1 N POWM. icy 25' o, q6' lo' - kS OEMVdAr___..____-_,---7 i & CA�3LE �" STOPM SFW�F PIPFS o'ELEVATION l; SMIrAQY TVkl?, 90' LEVAr 7N 7OWN5PO T 5117&W� • ►, \ �PkOPEPIY LINE 100' / II: . r'''' 1 a'...V,5 i- - - -• • - Ls\ r ,r '- ZJ�— 1 `' rr, • i' 11 11 E 1', tE Sz JJ_' [A /y� a1 ill L fit le 'r _l� r TI �� 1 E i'�I.. ,__,�,.,-_-._ • 1l-£i :11 l ,„ ____ -l--V irr - IIE_I ! JI Yu , ., 31 1 131 '11�... .2111,1 / r_-, ,'-I I 1 it 3I 11 - 0 ' lM_= JL_a01 _'J 1 i i11 a11 O I I ,r l\5 F 1 1 , ( I I Ll Li J .. .,,_— 'L \ H 1 Z f_JJJr 1 1i i i'= E1 _..:;�..� 7 Ire � `- ��« {� {.�{{ _il i1L E i '1 'L 05 I. r 'i1 .0 1i--- �L--d>•-...._ -,IL PAII0 =—=f sL_e=��'' 1 _ n O h ! An li`\.,',{ i I 1 1 O , 11.E li el > '� r, sL1 f I i 1 >AY_ '.>•',. 1E 7 4 i r�-,j IE r3 al 44 ►,� F 1203 5112:�T : "'3 r-r. I •3_, lie_ 1 �_�_, 1205 II-, 511:�r1- �;_ I - 1u11 ;Ir�� 1li 1 1 I Lv J, 3 Ei 1�1 Y ,� F�� 1 I t il��_hi ..1�_ I\ I n [ i I I f}r-yl I 1 ,I 111 ,, IIrl clt'T1, II 11('__J I .' I I 1 i r-e L_..y A JLJ II 1 L f,- ll "f% 11 __ 5�_=4.._y' -:a-.i .�= - __--'J If 1 --oiT`fir=7,�-�-i1 11 1 rl�l'£�:';�I. 1 I ;_-'- JIl �. ' L -�'i�1i 1:{��---t-� •y'. `Ym 111 i 1 11 1_'_F� II 1 i L____'�L _7S __2'-_'_` _tea'. _'1 1--_ 11 yj �"a �1 FL IA to V� 07 ►I4 f7� rf% r43 ►ny1 r .- fi► p m far fi`r • ID •3i1 0 n .A fi. �. fi fi N SIq�WW K r \ \\ \ I I. ,.... .. ` �' ��� �t4 h '` ,.' Ad v a♦ ��j PAWING 'fit wa 1AV fi► 40 fi. i► rtm fit fi p No 0 1i� 0 Ca �PRK 1`l9.HA-1' __ — `\ Ili_ £1 _II} _�? w r 1 �.—_ —�IIi- i,rt_ V1 L -Y"'�=31Ed��_r_..,_ I — �n� i I' ,._..JF11r 1` me �l — I I__y y,%F:, I' r LI it II IE c..__ F 1 11 FF '____�`_1lL_... _ 411, rirt� Iii+ LjL_j, 1 f Ui 1/1 Is1'.rJ ���\_�,-'- , I { IrT,a 1I i'"?71 r-- Al I. I 1 1'1 L H i- -1 'll� I y''L11 £ 1`� I l i 1 ' l Nt.JE >__J / .11, Yc_.rjJJ_ !ill Il = M k1 �lsk S � I } . _> I �� HD I211 I�0 5T � 1 1 I 1 11 I 11 I!U;r _; Ia • f. 1-! ••__�i fry � f-:1T = }~_..B_�.._ I I : , 11 [V 1 1 F i 1 1 :•11 ,I L--_J I , i tlqc1 }j �3 II s� '1 I i`\Ili(1 ° :1 L---1 1,EIl i1 0 f. _J E �- ( .� r } -7 / L__ __ EI t V 1 6' IL_ -- -_ ,I PAT© 131 1 ! it t ft } JI �« }III 11 rF';N,Lr e I.i F..• ,Sr4� H III ,' %IIEI Ya✓ N ,I _r' 13 1 '1;:'I L"" 11 �� 11 .),.!'1' 11 L__,_JL_LT'�::.0t 1 �; E !'�I.e i' 1 -- iri f r u -,`" __[KJ !n +l n ° 1-=---:t_---11 r 7;e. _r,.rizm} r'. r rf z -! :I' ro7� O [I I '1� f�� 1SI ;I �I I I 1 : erl�r III it {r i11. aL' __ 1 I 1 1 1 3 s i 1 I 1 rL _la :L______ J. li 4___q L_J'1 I' a E ' 1 • i I l' o Lt ____ _ J: L_..._J_ 11 e1 1 NE , I i . _ ' <_� st»-r,�..�ir•']�s F�.7'iz'a-tr-.5iss_saa.r O 4 " ELEVATI N [ \ -- -- \ - ul •� �115ropM swF�pier 19°"51'01_tr 1 120714th 511',) -1 Lovv�R APAerMENT I209 €nth STP. T • ` f0 A'P12figNI-P001 E / d► • �`�4-TorI rTY LINE 100' ''� 6011 ELeVP.TION 10' i 25' gr _ qb' i 10' k CITYWA7%MET1ip5 12MWINCI INI2�}(; II^al"pr�eRsze-- c�:ls3i;z°' ccffrVI� Cof18 CXI5TING 1. 517E FLAN22"x „PA P,51lf---5-CCA 15>/1r7",I'(COf'a @ 200%) At717 2 MOF 2, NQ�M PI?OPEpiY NLf VRT1ON 0. 1207& 1209 C LI NATIONS LOT AREA 50.1 T,- 8998,2 51 PLAN 2. NO;20 ELEVATION&FLOOD PLAN 1. 1207&1209-MAIN&LiPPFP FLOOD pLAIJS 13ULi?ING AMA 50.Ff.- /1269.1 II. 2, 1207&1209-FOUNr7ATION PLAN PCPCENT Or AI:EA COVE C- 47% b� �p � 5. 20311203-SECT10ANAL& 3IKE WALLAN:, �, 1207& 1209- C PLAN 5. 1207&1209-5PPE1 FLOG':FP.i1MING PLAN& r.00F PLAN 1203, 120�, I207, 1209, 1211 WTIQNAL DETAIL I1TI 131M—i- NS51I7NCF5 b, 1209-ELEVATION 5, 1207& 1209-MAIN&LiPrl p FLOOi;513PACE WALL LINE PLAN 5PFINKL II & FIEWATNR 7, 120_9-FLOOD PLAN 6, 1211 -ELEVATION&FLOOD PLAN f3JI1,17Ei r0v ?IrV L t7IMGN510N5 'A'CN,#. 1'S5295 8, 1209-FOUNDATION&POOP PLANS 7. 1211 -FOUNDATION&POOP PLANS (ON5TF/IL11ON rOcoMFLYwmA-L. 0 I0,fl - r"-nn,1AI P (3pArr Vt/A1 I I lklr•PI li!SI P I711 .a=r,ri/)n 1 of n r l7nrr lhlhl I 111.11;ni a I I 11r171 CrLTG o G*r7.-"UG1 1T1111 I7IkI.I rl.S lee •-,,-.,...-.,, .._.,_._.- .--• i c- . .- . Ni .•-- .-,-;) .,, i.„.t. \ ,,,/) --''' rr% I '') '''.----‘-''. ' ----74) 1 , 1 -- , i •01,-.-, , 1 • • -: N -..-.' ) •t '\-,,, , - .\ 1 _,'- ,C... ' - •., x-, c ..., _. .. , .. i r \67:J t'4 8, • t.::: ' 4- . i ,.....„/ '1•-.)- I-,"Z ( (.). 4.-. ..'i .7-'.•::._ ..„..... , N ...t, ,, .,,_ c' ,. ,, ,. . . . ., ,,,,, i• C.,::: :1:;:-..;..'-'- 'I'''''' ' 1 ..z , ..- 4 ‘,-, , . -----__,__.------'-'-- - -'- ' \---.• tL.'.k-.?-It--.3 - - __ _ .__..-- " fr-- 1.,..• 0 o' ,. . r-•.?.. ,P • 1 N. ..Z• Vii.-0. ,, ----„, -7.,:11-'. ---, C. ....?4••-.... ,-.) '1"-C'1. ip-4'...-.- !.••' - - ...._ , t•----, • „..,_________A 1 -.4,-. . . k ..... 117,A, 0 F • ( 1 ..„,..4 _ ,.., ,, ty ., .- 1 4. • • 1 - Li .! ''''''N'A-Nr."3. ''....• .(1') ''1,r :PIZ , ) F41 1,1-‘,A •C:, ? 'Li, ._(11 . r , ..., 9 ,--4.- p ,,,_,,P,_.{.., tf...,/ I ....f.77,...,. , __________ . i 0 • (-„.) . .------) t, 4,,___ 4 f, ,......,...... i ,'., .s.......›. .,- , '1',, " k,...k.„.'Li_f'15.se 4'''' ' )'i• '., l'1.4 f.k„c''. 4... . `_•.1.i.- .4' J .'-- (r----6 . •_ ,, r .,-,j• ,-('':". ,:- ,..A.,. , ,-.. i'•-• (- -C-' • _. r:-,,, t; II". \ j ?„-'t. 1.,,',.'•. -k, ''' , '' '.. . . ,, .---.)\) ', k - L, • --... - ':1/4, . ,,, • ., ---....-_. itri ,.... ...,) ,,,, i„,.. 'i' ) ' . _ k -1 \,L ,. i'.!.._i' • . '.:' 4,'.., . . . A : T:i .•I':.-..: • . ,,r. ty , i:-.:---F—v— -, ,...'2,,,. ! k • '''' C.)\ ) i,,,,,2' 11 I I\ ,,..,,,,, , i c ,„ ,,,r,(..,,,,,.,:t„. ,..„..._ :, 1 4 I. 'i ) ' \ ,...! ' , ,,r, ,.,,, ,•.:,..,. i ..., .c• '' ...k, ,,.“if , .7,,,.. ., 1 • tr'' kc‘,..v.1 ,?-: k• 1 ..1 \S ti 1 - — (Vet 4' et-'''''7'.-= '''f '':-'' l' ''''.-- 'V --6:' -.. -,, ,---- ,, C.____55:',''"...,,-. , , .,-_k ---, ,i, x.,.„) •', + '•,f,),'i• . ' --•- i ,.. , ,,,;\— • • i v -..— : ,-----...., . V, , (1, \ . .?......,,, p- 1 ,......\ i ..).1(- k'. .,-,,.4 ',d k ... .' C ,, -5- ..---• '' ' • ..,..-,,i ":„ . i., ,.., , ,.. . . , 7,1 -.,.. , . ...__. ....— — • '----- , • sA _ — fir.- , C--, -\-' ' r I' . - 'C 5 ,,r tr--- (1.',4- „.t. \.,...., ,,.. ' !/ fLi/LAJ • .J-V LA t...4(4..-1-71 iC1 1../1 lac) 'AtJ I I/YWCA-4 7C-14..Li VIVID III l'cl 11C.0 0 A.4S7_4-', IVA/ I 1V HIM AlChNO)01 NOUJIAI-SNO 66Z6c '#11)AIJ NOISN'10111 1-W A4c:I1A GI Ncrii% 5.1.1\1 1)\116-15A1 Jllai-S '1171 coi 11N\ici INM AW,‘,.;i0 aNN?lalli GMACJV NV-Ici C100-1 'S SNOIJA/A111 , - S.2.I ,..--NimIMMmimmE 7 1 (%coWOD) I 7/iSITd%- ZIth k 7 fm( 001aAdO» 1g/I(1 Z15Gi GI I r ii iom \.. _...) 1:10:3 2,01-1iNV LP Ill/1 III I -ZW: ndopac V;)/ a 6:10\1 l ' i+4,r IL. JM 0 -,111.)1 • 1 5J-111\11P v‘Nii_tjw.,...(0)0 NVld ,010' . 4V0'4 30 11/4-1';'.;19(.11 •:.'''::,, ::"-':-,-.[•:1,._---U1,15 lltiVcIO 51,1111VN ?,d11-INNA I/-9 ' `,[- '0 V,"%W 11A11 r ,....... . 14,-...,,..,...[0. Gf1J-5 kail 0.1. !rQ,•-•.'''''••4' :•::'4.14-2--- .1A11VN 9N11,41.10ri Sall; •II.Z CZ) I .6Z --:r :1,4-..-.--:-.1-.1:::•:•..,•, ,,,:, .7'liZI '.,:11).'N PY ,.!:.," ."-:.•-,---..'7,14.--'.`:•:•::::: TIN/1-6 '1.4::,',...;•••..4i.:),:::,•:;,r.,1,. SAINI:AIONIK/JJ- 1'.1::••;;:.:::::;•11'r,,",!::::,k __...-00W,1,1..91/4 111N 2.1-)101101N1 Ild 71:,:•• ••••••••,,,,i'l•;'f••-•::•:":f.t -:- I 1 '411.-1.;:;:-::;:..!1"1.•.::.:,..›.:,:•: r .. .19-19 .01 .'• .19-19 :•-..1-;,...•:••4l2----1,:..„4„,....4.: Zli 7 / I irk1-16•— - -,9 -'._ _ _.'g-p,1 lip,' .......---- /-49.. -. H:'"I • : 1 1 %HMV ,;%)VIVA 1.1-Yld JO:1-al -s,-. •••,,,,- . 1 ..7.ri,Z;11 gq:" 1 ..\•,.1.50c1 14.1"747-)...1 11.1.0.W1-15 I Cid)99 1 1 \0 AIA',-1 -,-110S \01J-VA'1'- .1- V. i ! J.JI.A0) I , .. ,, xoc„,,,,6, dm. I I r' I . .. .1_, , - r__J —I ° W:ald WO l'101'OZ s4 s, • '1, .- `r r ,T. ,; , , -r -r•-. _ ,10,,m I I / 1 „ ,___,, zno,P MI- 1 1 I! I I i I II, i i 4 i j' ; i I I - I1N I-lain OH i r I . 1 l'I 1 ,. . . 1H 11 III = ,,) I I 1 1 11 1 I HI VOID 31 ,.)-, -T \ 1 ' 1!.! I : I: : f _. P I IIIF+ I I II I ; I Ill i 1 I N11/111 ,rp A. .,, I - IMI . _ J., NIN161 i 4.)''' ;,,t- rt'''; ; t4•';'1;: . 'TH."; 0 4'0! „u_,; '''f ' '' I I; ii ,_114i1A1,11th fr.;.-F'I', •• ' . :,•,_,, .'..T l'• qA'... -,In-I-rn.rrn-p. . . ' I - i• 1 t 1' IT- 511-Al Wk%iall'Il JAL 1"1 -' ! E ..) c•DK' AY. - T" ' -:I' -r"1:;: ,u, •:•• • 111.:#-L. -- t::r.r.., ,,MT i': Fi-pr''' —,_..) .:: -:' : 'il-1:1:17 .' 7.7.4,- 1 , 'i i i!., 11 L ,, I ,, '.!_i 1 I I I • , : ...x,•• h:rti ,,uuu A:H;,ii,(...,•?......:,,4L. 1 , ); ,________,_. , , , j_ ,,,.I. 0 INGI '5.)...).,91 6 tOZ•-..., ! r r —1.' -1' 'ii;LI.1 • , ,Ji,,,,. 1, . IIIIIH4.444 -I-4. . 'N dit ,,, -t..,... -- 91 55D2ri 7111•V ' . . ---- ,. --- • . );_iy, •, ' pi• Ihrft,L,'IIttl.'ir.I..vr 471`-',, ri 'Mr! 11,10 • •:•••1 1-. ,.; 411 Pi' -itii gt.111: ••• l'',,,a1111! 1 , •• 17-Fil-IT .. - _,„,t,'n',.' il-trt • • , ti.,.4 o:I. ,,,,,J ." ,.. . fig,. ,I Ellik-. -• ' I ' I 1 ' 'I II T•' ‘ ,.)i •ri,,A. _?:.t., . .t 14'. ..d 6rri, I..,-II1 rI,' .0' -,- Fri. ,' . - i . z '-----'-,y,-'6 9.-Nd-Id„ I 1 - ,C- - 14 . %:ft.'.-•'};I t. ji,j-,t • 't'.4t'.l . .di•-• n7 . .iii..,J,1-frnr . 1, , , .-. 1 ,, c 9 ' ll : Kil'''1 NINP41J 11 '''' — \- ](,...ii.. '.7 . I.,A, .7.,..)1-..,,. :=,;), t•,.: • . . -1 .t Li'i•Latni 'h. . .-r.,:t1 t.:ii .0,1,-.N',, r1...-M,.„-r,444,. .,:,„,, ,,,,,,,41,,„.Mt.111:0.11k,li.,,1,„".',.'rl - 1"" ; . ; a .11. ',J.; i. .-1 = a, - E - .,.= ''vj II , ,I, ,... •k)NorD.0 ! - - * - 1,31- 0100i61Jj 6_ c° I c"). 'I (--)I_ID;P t —0— OVA 51 ON \01VA'1' IS'W — Rtv6 ,011,1z1/9 ---iy - ,•„, ,,o-,, , , ,,,,,...,..,„.1,— 1 . - - 1-..NI- ! 1111, fl'' 1 TkicZ'01, . v.- NA- ' II = i .--. . . r -L'i -1-.-' r '7 T T 71 71 r -• N i Jgg .2,C.fer) L_ - mr _ allI) k- U•-•tral '..____.: I I ; : I' ' k 1 1 I II : , , 11 t,-4,11(115 1 1 1 :: 1 1 :I 1 1 1 1 11 . , _----•: _ (WOO U 4,1-‘4`g "-IVY Pj'P.z I' L 1 1 1 I F ' ' I i 1 -'': 1! I 1 '' 1 11 1 [ 1 1 F L i II i ,,G-•,, !'"---4- ','11--,,r I 1E ' - 1_,... ,.!1 i,., _ 0_ Z 7 . - _ -d:',W -.' AT'lal I I— --in%cIdl %I-1d-ACEIV1-1 ._.. . ; : •'?—.5 ' .57., ., , lit' 4 -1,1-,! r11. .•, ,,„: ...,,,...„.,,,. .... .",., . . , ..-..., • : I:t • ' .. t,,titt,:;,-.Y'' 1H",'T . ,'' ‘•:•,..ft-t-i' 1-1 ii l I I -li ' 1 •••• IC, ' fill il iL .--qh., i , ii lir I FL1_1. .n,th'..IH'44`1 PI,.,.: ff t.i'n .1Lri`II:ri.rr . 11-1 (r-,,,,i7r ' ' !I V!. ,I.I. .. P '-..."'-'7;'::.)...1-10111 A,T4.• ."11PT ' H I.i., li I Fr', , 11--;Li' EI7....."-..'I.. .. .a.V.T ,17.1.1.111.44.i., .1 PY 1:::'Ir'k? - 4 -:11:7' .1:1,- Hy :•‘...,. ,1:1"1 1...:-- 41112'.7_,1173 4[11Y,L71 ."; , 1; ; 11 1 , ; ,. 1! ;I ; y..X'" '' .;7111. Tr" ; 1.1_1 ro_Hi;;:i,.1 'II -1-"-W- ..`r • tttrr': ttn--....,„*. . •-1,-.FiYtrhr,11137. . .• _I 7F 1•1'L11•1...ar...ri.•„. pr: 51"..5.,1- 10/-110,H. ,' ' 44'd 6'1 .,.-L,i ,11. ;!. 1j i; F1-Tri.?...ji.r.,,....j-,b. ,,-, „ r, D.,,r: ' -:-'[i, -1';1 j.li,1'4::L. 11:::- 110 • •fq . ,'. d A ir in -.-iffi N , 41 ',ii_,',. If: :: ji 1.i„,:,:, :,,,i:LL:,:_ .,_, : ::ilii;':; •';',La_:„..:'j_,:,. L_L,1. ..;..:2:.:u.: , LI '-ev,- 1-J (3c ‘c q J\:. %;-..1 ',. k,%-- ,--, i ',' ----)c. t-1-- — __T-1- 1_ 3 I .-J-,"4,Fit'v--- ,. o I ,4%),) /I, c., ram.- - ‘\ I ut Is toyiki\ ...4„/..2,,,--- I 6 otI ,.47. , 4 lir I ,.5 lilp (2-) t-r;› 1021 -- 1. 1 = �f i , , 0- Ir.? 6 -.-'- -iP , 1 i \re21)%>bc /* ,. i. 1 bj1.\ P\-tviivv--- IN, Fv.is ...,"\,1 \--file\ 1 12_ .-3, Ros, 1 -2.m7 Ric) LP* j - — . Pt --t.c ,r L4 )V\1 I � I it ( fit;. � " � V 1 ' 7 ►' ' A 1--- -Q, rrft-- 1 1I.t S p-1.+2:_s NN ( l'-ferl tLe kij %'-.3, 11"'.( \01 ti 45.,'I L.10.t , 4 \il) \ i L______:::4t. t...... 1 0)04'0 i ?r‹.____ --2.j5. Lis ,,,,, i 3 ______ ______„) 1\ 1 • • - -- .--- . 1 ' tpki-u3k4, 4'\ ',a NI f+js , - . 1 � r ,----„---___ .• ,,,,, _„„ _ ,, ,, , , ,,: y2.1 ___ _ .1 ' 3'94 \.,;, '-^ N --1 Z 71 1-- ,\,,,,,, ., 12 V,...,1/ . 1 2 lellfr 7 1 \-2_o _7 '1 '1 , - 4\ 1 I I f ‘ 1%) I C-6NeNk \ticitty-- 11•21't \ 2-41 9 - 3`1 r 1 tAJI\D use. t ' ` , - - . '� l . c. ) k 4 i ..---. i 12.zkS , tz. q.1201 E I 1=f- --- . I 1 ••, t-(t__ 7(--. _____---------- 1 _ _ 1 II • , ---- ' 1 T - i b4'1 .\ 1 - 1 1 • D % s ' I, .. ..,,.._........._____:_____\,raei YN-- . 1 - i I 1 .,_. ! B m ikio/N , - . k i , I -3 I ` i 1) 1 � I ; , 1 t . - 1 )263 1 1 V ji. I ) 2_ 1 I 1 , i � 1 . ` 1 14 f a i / j _ i I i ' ) - - "k------V 0 s i-p t. Pl- ) Vk-‘,A ÷ - - <;_ - 1 1 ' , zz 5 •L -in, •2___c -7 / c-2_,0 q , , II ,e, ~ ` f e.3 p.) -i-C t\4-1°.4 ra 4.... 1 ' ,---; ii_ ____ _:-:-/-1411 I I . Dilv-)Nezir 0,3 ild-• !' (N.73 B 1\ fk__&\A6r.--- _Si . iz1,-- v 42-1 [r3 li 1 i r 1\ -1 (-0 S- - - _ ). i, . _ ' 11% if\' -__ 11 I ) -13 i 1 'I I 1 ti a 1 1 S • 0--- LJ H - 5+ , v\i e 1 I �t 1 i I` 1. MOST HYDRAULICALLY REMOTE HEAD ► J1EAD # GPM PRESSURE REQVD AT STREET 2. HEAD i : :. 11.6 GPM 26 PSI 6i; 1M� ifrr.-.,a •- =-1 1 " HD SYMBOL MODEL # K FACTOR MAX SPACING ~ Ipiliq , I{: RFC43-12 SIN-RFC43-RA0612 4.3 12X12 illi•WziJ ' RFC43-14 SIN-RFC43-RA0612 4.3 14X14 r �,,,,,,1 °� �' 0 RFC43-16 SIN-RFC43-RA0612 4.3 16X16 -all °0•-s~ - 0 RFC43-18 SIN-RFC43-RA0612 4.3 18X18 0 RFC43-20 SIN-RFC43-RA0612 4.3 20X20 Temp 'K' Sprinkler Max.` Norminal Minimum Required Sprinkler Discharge Model Orifice Size Rating Factor Spacing Distance Single Sprinkler Two or More Sprinklers (in) CO (ft.) To Wall Flow 1 Pressure Flow Fa. Pressure Ea (ft-) (9Pm) (Psi) _ (9Pm) (Psi) 12x12 6 12 7.8 12 7.8 • 14 x 14 7 13 9.1 13 9.1 SIN RFC43 1/2' 165 4.3 16 x 16 8 13 9.1 13 9.1 18 x 18 9 18 17.5 18 17.5 20 x 20 10 21 23.8 21 23.8 I I I 1 NUMBER OF SPRINKLER HEADS: 07 251 e -. 51 - IM�II I_11 I II I WATER SUPPLY It Requires esInsul the pipe A'�� �' It Reqclrea Insulation 5e moved SUPPLY allow heat from the a sprinkler pipe toee 314" METER space below to transfer into the • attic space and keep the pipe STATIC PRESSURE 60.000 warm. / 1- '1 - ---- - III-.42I I t , RESIDUAL PRESSURE 52.500 AVAILABLE FLOW (GPM) 30.000 f{t11.II I'-7" TOTAL PRESSURE REQUIRED 37.924 I- 67- TOTAL REQUIRED FLOW (GPM) 26.000 2x6 ' 16" y� TRAPPED AIR SPACE - 1 ' X11 L5 SAFETY MARGIN (PSI) 16.321 LBAITINSULAIONTENIEO OVER PIPING SAFETY MARGIN (GPM) 4.000 TENTING - WALL - --, "- 1 1I CLOSET LI 1 E ----IN ,, . 1 A V. i tC1 BEDROOM 0 ) n n in II ti Er CEILING L.Y 2 ' !� _ rl.i Ir1�. i 11r�9fI�;LIiFLE - -- - tritt. - , IP z _ r -- 4 _ _ fir' (30 i 1 -N: ., I RFC43-16 RT04,Nii j ---n r 1.3-12 _-- `- --IN H'4 1 H-1 ------, Q F tu _ 1 L�4 1 '' r BATH 1 N ' ti1 l_^ "��` fi I 6'CEILING I ,,�q�� $1 _ / � ' I I -IN w r __=�, ___--___-, r _-____ I r; % CLOSET j W' MANIFOLD EXAMPLE �� • I, - 1 --, I . --� FBI' L =.:,-16S1. 165 _ 1 - 1.1.f- - -- - \ ! l s f 1 1 m4-5TT 'tiidr.hr4LJ8 -I- PATIO ' i I t I I OR III"--"f... 1 l I I DINING I :1.- II;,1."1 -:. :'a?.C„ly� 1 I X I W Q I N.G 1. B'CEILING Z , Ri ELEVATIONS-CROSS SECTION OF HOME pi c rJ r %e I I I I ��Fw , { Uml "g 4 1 ! I H N 11 1 1 rnr� I- !IV!" I I .=1 IRF 4 -1!ISST-16 I r 1: 3-16 11 III --- Z 0 >0 W -% - I01-1.7 ;�I. I I . # -, Zzz O O I I ; EJ_I I I - 109 FT uj , ,w - 0 LIVING I KITCHEN f,t'^h I l LI,J Q Ili 1 Ir COLNo I .8'CEILING I L,)�JI 11 �• CC II0 Ce 0 I 1�T1 • ri �f 1 � ~ -� I wa p � � I MAIN FLOOR S.0 - 102FTCO - - G �1112 Lt 1 1, 1- -- - j, 1_ J 100 FT uju j c.,) ct - O I 7 \ (� /f �� iT -- HV? ILL; `,c W CC Z _ � - 1 I L �__�__, I AMP I I O O CoN 1 1 I - CO p Ce 0 ~ O < r1'• t,l 11 ,.r I 1 �./�) rCrHI fy0 I 1 a Jr A AL i Q a , I I � VI 1LLI el- -- N 1, 1 • 2 Z I!�II_!.II 4x8 . . I -_ - cn r N MAIN FLOOR PLAN • LU • U-I m W Wz ce W H < g 1 9limn 1.1:5: CO 7 c l >61 CO " ' I- 0.% 1 W rl� R ! 2 34 • L� J J ion 0 r- 0 kZLIflC M Z Cn I_- i33 D1 c N Z Ce L) x - r� r-. W tiin OI- L . .u.l W EaJ � 6 N. in ua a� , • S 3 a Qi m - J I JJ W pr (l 4' _ MCe �� ZX N - - Q ,J CO ❑ & lrliaa CD �' Q V r U- aco RESIDENTIAL PUMP - NFPA 13D 2010 HANGERS AND SUPPORT-CPVC FLAMEGUARD 1'1PE GENERAL NOTES CONTRACTORS INFO, OWNER STANDARD SYMBOL KEY HYDRAULIC CALCULATION SYMBOL KEY M ti 6.2.1' PRIOR TO SYSTEM ACCEPTANCE,A SYSTEM UTILIZING 2. PUMP MOTORS USING AC POWER SHALL BE CONNECTED TO PIPE SIZE MAX SUPPORT SPACING 1.HORIZONTAL RUNS MUST BE BRACED SO THAT THE STRESS 5.RISERS MUST BE SUPPORTED BY PIPE CLAMPS 1. THESE HYDRAULIC CALCULATION'S AND SYSTEMS MEM 1" FLAMEGUARD (CPVC) PIPE SPRINKLER HEAD WITH HEAD S.0 SOURCE Dla INSIDE DIAMETER OF PIPE 0 -CC'► COI O A PUMP SHALL BE TESTED BYOPENING THE DRAINITEST A 240V NORMAL CIRCUT. LOADS WILL NOT BE PLACED ONA FITTING ORAJOINT. OR BY HANGERS LOCATED ON THE HORIZONTAL ARE DESIGNED IN COMPLIANCE WITH NEPA13D WILLIAM MENDUM CONSTRUCTION WILLIAM MENDUM CONSTRUCTION H NUMBER, SPRINKLER TYPE M C CI) CO CD CONNECTION. EOM5-1/2 FT SUPPORT SPACING IS SHOWN IN THE FOLLOWING TABLE. CONNECTION CLOSE TO THE RISER.ONLY LISTED 2,ALL INTERIOR PIPING TO BE"REHAU"PIPE UNLESS 1.5"' FLAMEGUARD (CPVC) PIPE H.1 HEAD NUMBER C-Factor INSIDE OF PIPE SMOOTHNESS 3, ANY DISCONNECTING MEANS FOR THE PUMP SHALL BE HANGERS AND CLAMPS CAN BE USED.VERTICAL OTHERWISE NOTED. BILL MENDUM BILL MENDUM `:rC43-1€, NUMBER &COVERAGE t = m 13.2,1.1 THE PUMP SHALL SENSE THE FLOW,TURN ON,AND FLOW APPROVED. 1'" 6 FT 2,WHEN A SPRINKLER HEAD ACITIVATES,A SIGNIFICANT LINES MUST BE SUPPORTED AT INTERVALS TO 3. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'0" _ DOMESTIC PIPING R.30.A RISER NUMBER FT FLOWING TEE I C) - N crO o toWATER FOR THE REQUIRED DURATION 8.1.2 OR 6,1,3 REACTIVE FORCE CAN BE EXERTED ON THE PIPE,WITH AVOID PLACING EXCESSIVE LOAD ON A FITTING PER NFPA 130,REFER TO SPACING CHARTS FOR PO BOX 1656 PO BOX 1656 • • r CO o) U. WITHOUT INTERRUPTION. 4.A METHOD FOR REFILLING THE TANK SHALL BE PIPED A PENDET HEAD,THIS REACTIVE FORCE CAN CAUSE THE AT THE LOWER END.THIS CAN 8E DONE 8Y USING MAXIMUM SPACING BETWEEN SPRINKLERS AND TO THE TANK. ® 6-1/2 FT PIPE TO LIFT VERTICALLY IF IT IS NOT SECURED PROPERLY, RISER CLAMPS OR DOUBLE-BOLT PIPE CLAMPS FROM WALLS. ANACORTES, WA 98221 ANACORTES, WA 98221 3/4" REHAU PEX PIPE I T.30 TEE 1 B 1 BRANCH OF A TEE 6.2.2 WHERE A PUMP AND TANK IS THE SOURCE OF SUPPLY ESPECIALLY IF THE SPRINKLER DROP IS FROM SMALL LISTED FOR THIS SERVICE. 4, THE ROUTING OF THE.TU$ING SHOWN ON THIS lij FOR A FIRE SPRINKLER SYSTEM BUT IS NOT A PORTION 5.A METHOD OF SEEING THE WATER LEVEL IN THE TANK DIAMETER PIPE.THE PIPE MUST BE BRACED AGAINST THE DRAWING IS INTENDED TO BE SCHEMATIC.THIS 1" REHAU PEX PIPE pie R STROBE o P.1 PIPE N UMBER 1 R 1 RUN OF A TEE Csilw 1 112"" 7 FT X VERTICAL LIFT-UP WITH THE CLOSEST HANGER. rr'V r3'f tit 1 fti [] a I OF THE DOMESTIC WATER SYSTEM,THE FOLLOWING SHALL BE PROVIDED WITHOUT HAVING TO OPEN THE 8.THE RISER SHALL BE SUPPORTED VERTICALLY DRAWING SHOWS SUGGESTED ROUTING ONLY. SHALL BE MET: TANK. WITHIN 2 FEET OF THE CEILING OR BOTTOM ALTERNATE ROUTING MAY BE USED,SO LONG AS PHONE (360)-661-6396 PHONE (360)-661-6396 2" 8 FT OF THE JOIST. L.1 90 DEGREE ELBOW PT PSI TOTAL 1H 1 SPRINKLER HEAD 3.ALL INTERIOR PIPING TO SE 1.5'SPEARS CPVC. THE SPRINKLERS ARE CONNECTED IN THE _ 1.A TEST CONNECTION SHALL BE PROVIDED DOWNSTREAM 6, THE PUMP SHALL NOT BE PERMITTED TO SIT DIRECTLY SCHEDULE ED FITTINGS AND PIPE. ARRANGEMENT SHOWN. EMAIL maggimmn(Storage@hotmall.com EMAIL maggiministorage@hotmail.com I OF THE PUMP THAT CREATES A FLOW OF WATER EQUAL ON THE FLOOR. 2-1/2" 9 FT 7.MAINTAIN VERTICAL PIPING IN A STRAIGHT 5.ALL PIPING TO BE SUPPORTED ACCORDING TO D.T DOMESTIC TEE P F PIPE FRICTION 1 L 90 DEGREE ELBOW TOME SMALLEST SPRINKLER IN THE SYSTEM.THE 4.SPRINKLER RISER DIAMETER TO BE 1.5" ALIGNMENT WITH SUPPORTS AT EACH FLOOR NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. CONNECTION SHALL RETURN WATER TO THE TANK. 3" 10 FT LEVEL,OR AT 10 FEET INTERVALS. 8. THE PIPING ARRANGEMENT ANO HYDRAULIC T.30 • NODE (TEE) NUMBER ; PE PSI ELEVATION Mil MANIFOLD - CALCULATIONS ARE PROPRIETARY PROPERTY RISER FLOOR CONNECTER OFE AND XFIRE RESERVES THE EXCLUSIVE RIGHTS - AND RISER NUMBER QA GPM L.2 90 DEGREE ELBOW TO THE TO THEM, UNAUTHORIZED REPRODUCTION OR USE IS P11 PIPE NUMBER _ ;1 s Off- FORBIDDEN. Up QT GPM QUANITY D.T DOMESTIC TEE Willgaire41 CERTIFICATE OF OCCUPANCY This is to certify that the below listed building or structure has been inspected and occupancy is hereby authorized: Description: New Single Family Residence Location: 1203 14th Street Owner: Bill Mendum Constructed by: William Mendum Building Permit #: BLD-2015-0086 Date issued: March 19, 2015 Use Zone: R-4 Dated: December 31, 2015 Authorizing Official: 1 . INSTALLED INSULATION CERTIFICATE *NERAL PLUS Insulation, LLC "A�svldiq�ffnare Efjkiency And area(C,ornjor!For Your IdnoTe 10614 COLLINS ROAD OFFICE (360) 630-6341 SEDRO-WOOLLEY,WA 98281 GM (360)708-3479 We certify that the following residence has been insulated with the following materials: Fiat Ceiling R - 49 Sloped Ceiling R - 38 Exterior Walls R - 23 (BIBS) Floors R— 30 // Address: 1203 14i1'Street,Anacortes,.WA 98221 Certify by Lot#: Date Installed: July 16th,2015 Title General Manager Lyrrce, Groc From: Bill Mendum <maggiministorage@hotmail.com> Sent: Wednesday, January 06, 2016 11:00 AM To: Fyrrce, Groc Subject: Fwd:Insulation Certificates Attachments: Insul Cert for 1203.pdf; ATT00001.htm; Insul Cert for 1205.pdf; ATT00002.htm; Insul Cert for 1207.pdf;ATT00003.htm;Insul Cert for 1209.pdf;ATT00004.htm;Insul Cert for 1211.pdf; ATT00005.htm Here's insulation certs Sent from my iPhone Begin forwarded message: From: "General Plus Insulation, LLC" <gpiinsulation c@hotmail.com> Date: December 29, 2015, 12:18:41 PM PST To: 'Bill Mendum' <maggiministorage a@,hotmail.com> Subject: Insulation Certificates Hello Bill: Sorry for the delay, attached are certificates of insulation for 14th Street, Anacortes, WA. Any questions please do not hesitate to ask. Thank you, Thank you, M&rift Nvvv0 GENERAL PLUS Insulation, LLC "Providing Energy Efficiency and Great Comfort For Your Home" 10614 Collins Rd., Sedro-Woolley,WA 98284 Maria Nuno Office Admin. 360-630-6341 apiinsulation(ahotmail.com From: Bill Mendum [mailto:maggiministorage{a hotmail.com] Sent: Wednesday, December 23, 2015 5:58 PM To: GENERAL PLUS INSULATION Subject: Re: Invoice 2662 from GENERAL PLUS INSULATION, LLC Any chance I could get Insulation certificates for all five units on 14th St. That would be 1205 1207 1209 1211 and 1203 14th St. thank you bill Mendum home builders 1 � f� -��� • am, - .- City of Anacortes Invoice/Permit#: BLD-2015-0086 r - 904 6th Street _ Applied date: 02/25/2015 P.O.Box 547 Issue date: 0 311 912 01 5 1 01 Anacortes, WA 98221-0547 Expire date: 09/14/2016 ,,• . (360) 293-1901 Ctp , Job Address: 1203 14TH ST Permit Type: Single Family Residence Permit ANACORTES WA 98221 Project: APN: Remarks: New single family residence one 5 dwelling unit lot. Owner: BILL MENDUM Contractor: WILLIAM MENDUM Address: PO BOX 1656 Address: PO BOX 1656 ANACORTES WA 98221-6656 ANACORTES WA 98221-6656 Phone: (360) 293-6396 Phone: (360)661-6391 License#: WILLIM*901Q4 General Information: Fees: 1st Floor Square Footage 671 Plan Review Deposit 200.00 Building Valuation 74725 Building Permit Fee 818.75 #of Bathtubs 1 Plan Review Fee 332.19 #of Clothes Dryers 1 Mechanical Permit Fees 78.10 #of Clothes Washers 1 Plumbing Permit Fee 83.00 #of Dishwashers 1 State Building Code Fee 4.50 #of Gas Fireplace 1 Sewer Inspection Fee 50.00 #of Gas Piping 1 Storm Drain GFC-Residential 1,383.17 #of Gas Water Heaters 1 Sewer GFC-Residential 8,828.48 #of Water Piping 1 Park Impact Fee 615.00 #of Hose Bibbs 1 Traffic Impact Fee 900.00 #of Kitchen Sinks 1 Total Calculated: 13,293.19 #of Lavatories 1 Deposits/Receipts: 0.00 #of Range Hoods 1 #of Showers 1 Total Due: 13,293.19 #of Ventilation Fans 1 #of Water Closets 1 C7 --1 -riW —.10 1 ,-t -, cn v, in a= f,.] ;..j i-'• .. 0i VO -r ri .'- F^'- r II' r—, s-- it..rt cc d� o c. 1-'- i0 ,-.. ;_, i t o r-- CD , _ I. z' o. -' 1- t-t Z' ,-i- r71 re fl .. 'it OD 10 F ' x tom' O -n r— THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DA, S, OM l CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMM ICEL : r' HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL PRIDVISLC N 'j OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, r1HE. GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER'r TATh 13k, LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. '-'' r r1 0::t w'. , �.. PJ e...1 i_<. , /\j''.%-77441 f' Icy'' f ( S' -''� `� SIGNATURE OF OW OR AUTHORIZED AGENT ISSUED BY F'' •-' !;.' ... ol pro=--t=`Ft - - - - _ _ • • zu ._ ubilt orks'- - • ?,-= -� - Engineering and Develop lent Services •1 Res-idontial Inspection •. _ Address: I�0-`'.5 — 1.4%. 517 7 e=Dat r z _z•_ i s ne►- L. • c l L1 us, 1)u�.e &1� �. _ - -:"Coactor_• ��l L m. th ii . - - ntr • Inspected by j :. -___- 1. , rP�n>� 1M: �va�1 . • Water Me ox•. S and level to finished grade or backside of sidewalk.elevation_ • • - - i box undamaged_ . " W meter and customer shutoff installed. . - -•• _ No .s, • . Accessibte-no landscape Obstruction_ . . • " QI D ev�ay installation has-drive-over box and rid_ = • !4 .er gate valve intact - • No leaks at connections_ - • ' . ' " - • . ' : ' 2: Curb and•G tter - ' Ill o cracks, damage, graffiti, footprints,finishing,blemishes, or other objectionable C' marks_ - if road frontage improvements: . ' - - ❑ •Expansion joints every l5 feet and at driveways_ f -Concrete has.broom finish.. . . low spot at curb tine, especially at driveway cut_ Maximum grade change in - feet is 74 inch. . • _ 3. Sidewalk • • i. o cracks, damage,graffiti, footprints, finishing blemishes, or other objectionable - • ciA . . arks_ - . . - • . . -, Q ADA compliant-1 percent slope to curb. - . • if road frontage improvements: -' ' . . ❑ ,Expansion joints every 15,feet and at driveways_ - - - . [] - Concrete has broom finish • • - • _ - ffq1A-4. Driveway Approaches Oc e`er ' - No cracks, damage, graffitilfootprints,finishing blemishes, or other.objectionable - [_T 'marks_ • . • • ' 0 ADA cornpllant - • . q4. 5: Streets _ _` . ❑ l\lo-cracks,blemishes: _ • - . if road or alley impro�rernents_ -• . • - - ' fl - Received proctpr and sieve analysis o€ballast,crushed rock,and asphalt - -Received passing;ma erials testing reports for sub--grede,-ballast, crushed - . • " rock• }-and asphalt_ - _ • D Received-tonnage tickets consistent with required thickness-per approved.- . plans_ • . . 6.. Sanitary wer - - • • t ction card'signed off and/or verified in Building Department database_, - 1 As-built record filed in the address fib_ • _ S ew cap(s).instaiied on clean-out(s),_ - . Clean-outs)•set at finished grade. - r 7_ Storm Drainage : - .• � . L.\ ��,‘� _ n `an•card.signed Off.andlor verified in Building Department database. ` • [As-b it-record filed in address file_ - ot blocked or.diverted to adjacent parcel_ . 04, a. Public_Utilities Out of Traveled Way ' 0 . Concrete collars around-City utilities_ - • • , . El Final grading ok . ' • - . - • ElRestored to prior condition or better.• • 9. Landscape:. 3-Ito. �e) - • ❑• .Bonded for completion at later date_ . Verified against approved landscape plan: - - . . . - . ❑ • installation_ ' - - ❑ Type and quantity of plants. - • • - ; ' 0 Sod or seed in place. - - • - ` , - • Q: Root barrier (receipt filed). . 10. Erosion Control pleasures _ •• • MPs rerrioved. • . . - All debris removed. Site clean. •• . ' • ` • Permanent vegetation established_ - • Anacortes,WA Code of Ordinances about:bla 17.28.060 - Minimum setback requirements. Minimum setback requirements in an RH R4 district shall be as follows: A. Front and side yard on a flanking street, ten feet from property lines. If the street is a designated arterial, the distance shall be increased to twenty feet. B. Interior side,five feet or one foot for every five feet of building height, whichever is greater. C. Rear,ten feet or one foot for every four feet of building height, whichever is greater. 1. Where the rear yard does not abut a platted alley, no portion of the primary structure shall extend into the setback area, regardless of the use of that primary structure. One detached accessory structure no larger than one hundred forty-four square feet and twelve feet in height may be placed in a rear yard, or in the rear twenty-five feet of an interior side yard, provided that it is set back a minimum of five feet from the rear property line, and three feet from any side property line. 2. Where the rear yard abuts a platted alley, a detached accessory structure, or that portion of the primary structure used as an accessory structure, may be built in a rear yard up to the alley property line, provided that it is set back a minimum of three feet from any side property line, and is no larger than one thousand square feet and no more than sixteen feet in height. if the accessory structure is a garage, built so that vehicles enter the garage from the alley in a direction substantially perpendicular to the alley, the garage doors shall be set back a minimum of ten feet from the alley property line to allow adequate turning distance for vehicles, 3, One detached accessory structure not exceeding one hundred forty-four square feet shall be permitted without counting as part of the lot coverage. The lot coverage of any additional accessory structures, or of any accessory structure exceeding one hundred forty-four square feet shall count as part of the percentage of lot coverage permitted in this zone. (Ord. 2756 Att. A(part), 2006; Ord. 2614 Att. A(part), 2003; Ord. 2482 Att. A§ 11, 1999; Ord. 2316 (part), 1994) (Ord. 2794, § 1(Att,A), 12-15-2008) 1 of 1 3/16/2015 4:39 P G4zY o� Anacortes Planning& Community Development Dept. Permit Center P.O.Box 547,Anacortes,WA 98221-0547 PH(360) 293-1901 Don Measarner,Building Official,Planning Director FAX(360)293-1938 March 17, 2015 Bill Mendum PO Box 1656 Anacortes, WA 98221 RE: Plan Review notes for the proposed 5 units at 1203-1211 14th St. Please address the following items so I can complete the plan review. £ti l. Show overall lot dimensions on the site plan. .c ,(,(2. Indicate the required side setbacks on the site plan. The East side setback can be 5 feet, but the west must be 5 Y2 feet due to the height of the 2-story building(5 feet for every 5 feet of building height. Zoning code Section 17.28.060, B. i j,,e 1- 3. What type furnace is planned for 1205 146? If gas,must have combustion air from 11 outside U or Please contact me if you have any questions about these notes. Sincerely, Paul Ingalls Plans Examiner City of Anacortes 360-293-1901 Fire-Rated Wood Doors Simpson Door Company Page 1 of 3 FIRE-RATED DOORS FIRE-RATED DOORS Simpson offers thousands of choices for fire-rated doors, including 20-minute fire-rated wood doors and MDF doors with fire ratings-up to 90-minute.And since Simpson fire doors have been designed to match other interior doors,your fire-rated doors will blend seamlessly with all doors in your home. Simpson MDF doors are available with 90-, 60-, 45- and 20-minute fire ratings. Learn more about your design options for these doors here: • Infinity Doors —90-, 60-, 45- and 20-minute fire ratings available • Ovation Doors—90-, 60-,45- and 20-minute fire ratings available • Encore Doors—90-, 60-, 45- and-20-minute fire ratings available 20-minute Wood Fire-Rated Doors Simpson 20-minute fire-rated doors comply with major code requirements for the 20-minute fire safety classification. This classification covers most residential requirements and can also meet commercial requirements for 20-minute.And best of all, Simpson 20-minute fire-rated doors match up perfectly with virtually any Simpson interior panel door, regardless of design or species. • Fire door designs complement Simpson interior door designs for architectural consistency throughout your home • Nearly unlimited design flexibility • Choose from two profiles—traditional ovolo or Shaker • Two panel-types available—3/"flat or 1-7/16"double hip-raised • Order in any size up to 3'6"wide and 8'0"tall • Choose from virtually any wood species • Excellent finishing characteristics • Select decorative options to meet your-design needs • Arched rail components • V-groove raised panels • Product covered—Simpson 20 minute (with hose stream) single-swing stile and rail wood door • Architecture Code-- 08200 Wood and Plastic Doors and Frames file:///C:/Users/Patti/AppData/Local/Temp/Low/SVNQ4MJLhtm 12/30/2015 Fire-Rated Wood Doors ` Simpson Door Company Page 2 of 3 Architecture Subcode -- 08210 Wood Doors o Fire Resistance -- 20 Min wlHose Stream PP Cat B Door o Swing-- Single Swing o Listed or Inspected --LISTED ▪ Report Number-- 3089369C0Q-005; 3137943C0Q-003; 3157209C0Q-005 • These doors have been tested and evaluated for compliance with applicable requirements for the following standards. • UL 10(c) (1998) • UBC 7-2 (1997) o UBC 7-2 (1994) • UL 10(b) (1997) o ASTM E2074 (2000) o NFPA 252 (2003) o CAN/ULC S104 (1980 R1985) I ' I : I F - - I * f i __. • . . 4 i _ . . . . _ [ , 9266 RP 9360 Shaker FP 9255 FP 9366 Shaker FP Shown in poplar Shown in cherry Shown in Douglas fir Shown in maple RAISED PANEL FIRE DOORS Stile 1.7/16'Raised Panel with FR core 9 ,,,,...,„, ,...,,, ..„„tr, „,............ _-, Bulinose / ) / '>''''16 J,11 ��'� Edge Strip .. . ., . ,�,.. � Woad Core 2 Sticking file:///C:/Users/Patti/AppData/LocallTemplLow/SVN04MTl.htm 12/30/2015 Fire-Rated Wood Doors I Simpson Door Company Page 3 of 3 FLAT PANEL FIRE DOORS SHAKER FIAT PANEL FIRE DOORS fit! g/with F Pa CCore ____:;57-:.\\ 1 ifil " F_/.7-'--,:. ,,-. . ,,. N , Edge Strip l&ewe -•;;:': \ /. -,- ....• - Ai1IJ4iiL -` Wood Core Shaker Sticking Available Options ' FII WHERE TO BUY FIND A DOOR liall file:///C:/Users/Patti/AppData/Local/Temp/Low/SVNQ4MJI.htm 12/30/2015 Q Cityof Anacortes Invoice/Permit#: BLD-2015-0256 904 6th Street Applied date: 06/02/2015 P.O.Box 547 Anacortes, WA 98221-0547 Issue date: 06/10/2015 (360) 293-1901 Expire date: 1 210 6/2 0 1 6 Job Address: 1203 14TH ST Permit Type: Fire Sprinkler Permit ANACORTES WA 98221 Project: APN: Remarks: Install fire sprinkler system info new residential building • Owner: BILL MENDUM Contractor: X-FIRE Address: PO BOX 1656 Address: 1511 KENTUCKY ST ANACORTES WA 98221-6656 BELLINGHAM WA 98229-4718 Phone: (360) 293-6396 Phone: (360) 715-8088 License#: XFIRE**961 PN General Information: Fees: Building Valuation 2258 Plan Review Fee 54.11 State Building Code Fee 4.50 Building Permit Fee 83.25 Total Calculated: 141.86 Deposits/Receipts: 0,00 Total Due: 141.86 01 -., l 4 Z, r .. • �-,, r•.:r r rr (iI I11 Q tr f;i I.-. `.. I'ti i;q 7_J.'. :-r ilti. rr) ir. i i i ik a. '.1 J l fll THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED 1S NOT COMMENCED WITHIN 180 DAYS, OIL I ' CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMM10EQ:,; I:F� HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL PROVISIONS. OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR MOT, IT:HW GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER, 'TAT7 :„O b LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION, SIGNATURE OF OWNER OR AUTHORIZED AGENT SSUED BY '— :: y - --_-t .. . - -- .iceMP Fire SprinkleriAlarm Permit plication " d5-7-3, City of Anacortes Building Department • 904 6th Street -�- Anacortes, Washington Phone: 360 293-1901 Fax: (360 293-1938 r r f : I 'i L Ali iii ilkik: AL li V ds414 1 ii • • LA] :10 Site address: Parcel No.: , • Lot: Block: Addition: -2 Owner , Owners Name: ti\\ �w 4 .-N _Phone No,: 6O $ M - i Address: iC.% jp Sfate:Mi ' Zip, . ____� r Tenant Tenant's Name: Phone No : Contractor information Contractor: X- C 4 Phone No.: 344 -7( 'ece ' • Mailing Address: 601 Kt f1t 1C.VN ' Q„Acre,eir . State'. VV Zip: 41 aa _ t State Sprinkler Certificate Level and License No.: cii2I, PN __Exp. Date:114081 General information • . . Please Check: Fire Alarm ❑ Fire Sprinkler . Modify Existing System ❑ Install New System r Underground Fire Line D Value of Project (labor and materials) $_ . . , „ J • Required Submittals Three(3): Scaled construction drawings showing•t#re following elements along with their dimensions z 1. Floor plan indicating the location of devices and appliance, end of the line devices, ; conduit wire runs, conduit size and number and size of devices. The zone Indication shall be placed adjacent to the appropriate end of the line device, 2. interior, exterior and underground fire alarmisprinkler components • 3. Transition from exterior to interior. • 4. Manual fire alarms and strobes (including installation height) ' 5. Fire alarm control panel location, riser locations and control valves • - 6. Door hold-open device 7. Heat and smoke detectors (identify type) duct detectors • 8. System Calculations and manufacturers information on system components 9. Fire Sprinkler tamper • 10, Water flow and control valves 11. Site Plan,(S ow FOC, PIV cations) 'z Signature: �J� Date: 5/31//5- Applicant or fh'aner 1 �, l UpdCcd m Novcber 4, 2009 G!TY CA- NACU RT E 'PH -Mr-�NF7 r Li E c ' . APPROVED PLANS :Miff NO-4/a: �•`r Ess• iliPPPICNED t3Y, -. '�._; ;IBJECI 10 FIELD uN PECT1O . CA/ERSIt.* s'' # VInLATPON OF nlIF IS Nr.T INC[ LJDr Fire Sprinkler System Calculations X-Fire Security 1511 Kentucky St, Bellingham, WA 98229 Job No: L-2573 Job Name: 1203 14th Street Residence Building Type Single Family Residence Location: 1203 14th St,Anacortes WA System Type: NFPA 13D 2010 a WASKINGTON STATE CERTIFICATE OF COMPETENCY e! FIRE PROTECTION SPRINKLER SYSTEMS Rodney L. Durham 8511-0705-A Level 1 X--illtrh, ./ N �� !Expires P a to 12/3.1/15 a,umunvss gem Ds!vx,ai ire mex,an c®ear ens-r M.mow min Designed by X-Fire Security- 1511 Kentucky St, Bellingham, WA 98229 - 360.715.8088 L-2573 1203 14th Street Residence -Two Head Calculation -(H.5 H.6) Page 2 of 5 Final Calculations -Summary Wednesday, May 27, 2015 Hydraulic Design Information Sheet _ Job Name 1203 14th Street Residence Opened Date 5/27/2015 Location 1203 14th St,Anacortes WA Job No L-2573 Building Type Single Family Residence Ceiling Height (ft) 9 Calculated By Rod Durham Construction Combustible Occupancy Residential System Design Type of Calculation NFPA 13D 2010 Listed Flow at Start Point (gpm) 13.000 System Type Wet Listed Pressure at Start Point (ps 9.100 Sprinkler Make Reliable Maximum Listed Spacing (ft) 16 Sprinkler Model RFC43 Domestic Flow(gpm) 0.000 Sprinkler Size (in) 0.50 Elevation at Highest Outlet (ft) 112 Sprinkler K-Factor 4.3 Temp. Rating (°F) 165 Coverage Area (ft2) 256 Listed Flow(gpm) 13.000 Calculation Summary Flowing Sprinkler Heads H.5 H.6 Flow Required (gpm) 26.000 Pressure Required (psi) 37.924 At Reference Point METER Overhead C-Factor Used 150 Underground C-Factor Used 150 Water Supply Water Flow Test: Static Pressur 60.000 Residual Pres 52.500 Flow(gpm) 30.000 Elevation (ft) 97 Manifold & Water Flow Switch Additional Pressure Loss (psi) 4.60 L-2573 1203 14th Street Residence-Two Head Calculation - (H.5 H.6) Page 3 of 5 Final Calculations -Water Supply Curve Wednesday, May 27, 2015 100 90 - _ 80 70 - - 60 ek, (n d 50 112 N N o- 40 - - 30 - - 20 10 - - 0 - 10 202530 35 40 45 50 55 60 65 70 75 80 85 90 95 100 Flow(N"1.85)GPM • • Demand Curve Required Pressure: 37.924 psi @ 26.000 gpm Required Flow: 26.000 gpm o O Supply Curve Static Pressure: 60.000 psi @ 0.000 gpm Residual Pressure: 52.500 psi © 30.000 gpm WASHINGTON STATE Available Flow: 30.000 gpm CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS >C • Pressure Cushion Rodney L. Durham Available Pressure: 54.244 psi @ 26.000 gpm 8511-0705-A Level 1 Pressure Cushion: 16.321 psi X-Fire XFIRE""96 •N 6 idpr `,ii-Vaatear •,p-isnt - Sseem U, U,�s P:n rm®•- 'Mrm w.-ras; i L-2573 1203 14th Street Residence -Two Head Calculation - (H.5 H.6) Page 4 of 5 Final Calculations - Nodes Wednesday, May 27, 2015 Actual Actual Elevation Pressure Flow Node No. (ft) (psi) (gpm) Model-Coverage(DxW)-Temperature S.0 102.0 28.398 0.000 SOURCE H.1 109.0 16.563 0.000 RFC43-1212-165 D.T.1 109.0 17.203 0.000 Rehau PEX 0.75in Dom Tee H.2 109.0 18.945 0.000 RFC43-1212-165 H.3 109.0 20.124 0.000 RFC43-1212-165 H.4 109.0 22.563 0.000 RFC43-1616-165 H.5 112.0 9.176 13.000 RFC43-1616-165 H.6 112.0 9.100 13.000 RFC43-1616-165 H.7 112.0 18.045 0.000 RFC43-1616-165 FT.6 112.0 12.601 0.000 Rehau PEX 0.75in Sprinkler Tee FT.5 112.0 12.677 0.000 Rehau PEX 0.75in Sprinkler Tee 11 L-2573 1203 14th Street Residence -Two Head Calculation - H.5 H.6 Pa e 5 of 5 Final Calculations -Pipes Wednesday, May 27, 2015 Pipe# Hyd. Qa Dia. Fitting Pipe Pt Notes 1 Ref. C-Factor Fittings Pe Point Qt Pf1UL +PrLoss, Total Pf p0 FT.6 11.158 0.681 10.102 16.563 to 150 1 R1 H 1.000 1.299 Vel = -9.8 H.1 -11.158 0.2399 0.00 11.102 2.663 sup° METE 0.000 1.380 75.000 28.398 i to 150 MNF 0.000 2.166 Vel = 5.6 1 S.0 26.000 0.0368 4.60 75.000 2.760 p1 H.1 -11.158 0.681 1.670 17.203 to 150 1 R 1 H 1.000 0.000 Vel = -9.8 D.T.1 -11.158 0.2399 0.00 2.670 . 0.640 p2 D.T.1 0.000 0.681 6.260 18.945 to 150 1 H1 R 1.000 0.000 Vel = -9.8 H.2 -11.158 0.2399 0.00 7.260 1.741 p3 H.2 0.000 0.681 3.917 20.124 to 150 2H 1.000 0.000 Vel =-9.8 H.3 -11.158 0.2399 0.00 4.917 1.179 p4 H.3 0.000 0.681 9.170 22.563 to 150 2H 1.000 0.000 Vel=-9.8 1 H.4 -11.158 0.2399 0.00 10.170 2.439 _ p5 H.4 0.000 0.681 11.186 28.398 to 150 1 H 0.500 3.032 Vel = -9.8 S.0 -11.158 0.2399 0.00 11.686 2.803 p8 S.0 -11.158 0.681 14.309 18.045 to 150 1H 0.500 4.331 Vel = 13,1 H.7 14.842 0.4067 0.00 14.809 6.022 p7 H.7 0.000 0.681 12.201 12.677 to 150 1 H 1 R 1.000 0.000 Vel= 13.1 FT.5 14.842 0.4067 0.00 13.201 5.368 p6 FT.5 -1.842 0.681 7.922 12.601 to 150 2R 1.000 0.000 Vel = 1.6 FT.6 1.842 0.0086 0.00 8.922 0.076 _ hp6 H.6 0.000 0.681 0.000 12.601 to 150 1 H 1 B 11.000 0.000 Vel = 11.5 FT.6 13.000 0.3182 0.00 11.000 0.000 hp5 H.5 0.000 0.681 0.000 12.677 to 150 1H1B 11.000 0.000 Vel = 11.5 FT.5 13.000 0.3182 0.00 11.000 0.000 Bulletin 006 Rev,D Rel iabld Model RFC43 (SIN RA0612) co Model RFC49 (SIN RA0616) Flat Concealed Residential Sprinklerscp -- a A Concealed Residential l Sprinkler engineered for a ` minimum design density :11; of 0.05 gpm{ft2 with low GPM requirements. f, Features 1 . Very low water flow requirements. • • 2. %" (13mm) Total adjustment. ' • 3. Thread-On/Thread-Off or Push-On/Thread Off cover attachment option. 4. Smooth aesthetic ceiling profile. • 5. Available in brass, chrome and sir*441".... black plated or painted finishes, . Listings & Approval r: 1. Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) 2. NYC MEA 258-93-E UL Listing. Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC43 and RFC49 Concealed Residential Sprinklers The RFC43 and RFC49 are UL Listed Residential Sprinklers are fast response residential fusible solder link automatic to be installed in the residential portions of any occupancy in sprinklers. Residential sprinklers differ from standard accordance with NFFA 13, 13R, & 13D. sprinklers primarily in their response time and water The RFC43 and RFC49 can reduce the need for precise distribution patterns. cutting of drop nipples_ The threaded cover plate assembly Model RFC43 and RFC49 sprinklers discharge water in a can be adjusted without tools to fit accurately against the hemispherical pattern below the sprinkler deflector, ceiling. The fire protection system need not be shut down to Residential distribution patterns are higher and generally adjust or remove the cover plate assembly. contain a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge Application and Installation pattern required for residential sprinklers has demonstrated, The RFC43 and RFC49, for residential installations, use a in fire testing, an ability for controlling residential fires, and 165°F(74°C)fusible solder link in a tuning fork style sprinkler thereby providing significant evacuation time for occupants, frame with a drop-down deflector. This assembly is recessed The RFC43 and RFC49 Sprinklers provide the best form of into the ceiling and concealed by a flat cover plate. The cover fire protection by combining an attractive appearance and plate is attached to the skirt, using 135°F (57°C) ordinary '/z" (13mm)of cover adjustment for ease of installation. The temperature classification solder. When the ceiling small diameter cover plate is easily and positively attached temperature rises,the solder holding the cover plate releases and blends into the ceiling,concealing the most dependable the cover allowing the deflector to drop into position and fire protection available, an automatic sprinkler system. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 exposing the sprinkler inside to ceiling temperature. The should be taken to prevent damage to the sprinkler. DO NOT subsequent operation of the solder link opens the waterway WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP and causes the deflector to drop into position to distribute the ASSEMBLY. MODEL RFC43 AND RFC49 CONCEALED discharging water in a hemispherical pattern below the SPRINKLERS MUST BE INSTALLED ONLY WITH 135°F sprinkler deflector, Any adjustment of thread engagement RATED COVERS. between the cover plate and cup will assure that the Cover assemblies provide up to y" (13mm) of drop-down deflector is properly located below the ceiling. adjustment. Turn the cover clockwise until the flange is in The residential distribution pattern contains a finer droplet size contact with the ceiling. For the push-on/thread-off option, than a standard sprinkler, and the pattern produces the cover assembly is pushed onto the cup and final significantly higher wall wetting. adjustment is made by turning the cover clockwise until the After a 2 5/8 inch diameter hole is cut in the ceiling, the skirt flange makes full contact with the ceiling. Cover sprinkler is to be installed with the Model FC Wrench. When removal requires turning in the counter-clockwise direction. installing a sprinkler, the wrench is first positioned into the In ceilings that have a plenum space above the sprinkler, sprinkler/cup assembly and around the hexagonal body of the plenum space may have neutral or negative the sprinkler frame. The Wrench must bottom out against the pressurization but must not be positively pressurized. Inspect cup in order to ensure proper, safe installation. The sprinkler all sprinklers after installation to ensure that the gap between is then tightened into the pipe fitting. When inserting or the cover plate and ceiling and the 4 slots in the cup are ail removing the wrench from the sprinkler/cup assembly, care open and free from any air flow impediment. Temperature Rating Sprinkler Cover Plate Max,Ambient Temp. 165`F/74`C 135''F/57"C 100'F/38'C Installation Data: RFC43 (SIN RA0612) Minimum Required Thread Size K Sprinkler Maximum Minimum Sprinkler Discharge inch(mm) Factor Spacing Distance Distance between ft.(m) to Wall ft.(m) sprinklers,ft.(m) Flow Press. gpm(Lpm) psi (bar) 'h"(15rnrn) 4.3 12 x 12(3,6x3.6) 6(1.83) 8(2.43) 12(45) 7,8(0.54) 1/2"(15mm) 4.3 14 x 14(4.3x4.3) 7(2.13 8(2.43) 13(49) 9.1 (0.63) 1/2"(15mm) 1.3 16 x 16(4,9x4.9) 8(2.43) 8(2.43) 13(49) 9.1 (0.63) /2"(15mm) 4,3 18 x 18(5.5x5.5) 9(2,74) 8(2,43) 18(68) 17.5(1.21) /"(15mm) 4.3 20 x 20(6.Ox6.0) 10(3.05) 8(2.43) 21 (79) 23,8(1.64) Note: 1 bar= 100 Kpa Installation Data: RFC49 (RA0616) Minimum Required Thread Size K Sprinkler Maximum Minimum Sprinkler Discharge inch(mm) Factor Spacing Distance Distance between — ft.(m) to Wall ft. (m) sprinklers,ft, (m) Flow Press. gpm (Lpm) psi(bar) '/a"(15mm) 4.9 12 x 12(3.6x3,6) 6(1.83) 8(2,43) 13(49) 7.0(0.48) /s"(15mm) 4.9 14 x 14(4.3x4.3) 7(2.13) 8(2,43) 13(49 7.0(0.48) /"(15mm) 4.9 16 x 16(4.9x4.9) 8(2.43) 8(2.43 13(49) 7.0 0.48 1/2"(15mm) 4.9 18 x 18(5.5x5.5) 9(2.74) 8(2,43) 17(64.3) 12.0(0.83) 1/2"(15mm) 4.9 20 x 20(6.0x6.3) 10(3.05) 8(2.43) 20(75.7) 16.7(1.14) Note: 1 her= 10D Kpa FOR SLOPED CEILING APPLICATIONS SEE RASCO BULLETIN 035. 2, 1 Maintenance Model RFC43 and RFC49 Concealed Sprinklers should be 135°F(57°C). Cover plate assembly shall consist of a brass inspected quarterly and the sprinkler system maintained in cover plate and copper alloy retainer flange allowing a '/" accordance with NFPA 25. Do not clean sprinklers with soap cover plate adjustment. Any secure engagement between and water, ammonia or any other cleaning fluids. Remove the cover plate and the cup will assure that the drop-down dust by using a soft brush or gentle vacuuming. Remove any deflector is properly located below the ceiling. A plastic sprinkler cover plate assembly which has been painted(other protective cap shall be provided and factory installed inside than factory applied) or damaged in any way. A stock of the sprinkler cup to protect the drop-down sprinkler deflector spare sprinklers should be maintained to allow quick from damage,which could occur during construction before replacement of damaged or operated sprinklers. Prior to the cover plate is installed. Standard cover finish: [Chrome] installation, sprinklers should be maintained in the original [White][Specialty—specify]. Residential concealed sprinklers cartons and packaging until used to minimize the potential for shall be Reliable Model RFC43, SIN RA0612(Bulletin 006)or damage to sprinklers that would cause improper operation or Model RFC49, SIN RA0616(Bulletin 006). non-operation, Model RFC43 and RFC49 Residential Ordering Information Cover date Finishes'1) Concealed Sprinkler Specification Specify: Standard Finishes Sprinklers shall be cULus Listed low flow residential 1. Sprinkler Model Chrome concealed sprinklers with drop-down deflector and 2. Cover Plate Finish White adjustable flat cover plate engineered for a minimum design 3. Thread-On or density of 0.05 gprr,/ft2. Sprinkler frame and deflector shall be push do Feature Special Application of bronze frame construction having a 1/" NPT thread. Finishes Thermal element shall consist of an approved black-painted Bright Brass beryllium-nickel fusible solder link with symmetric lever ack Hating mechanism, maintaining a Teflon-coated Belleville spring washer and machined brass cap water seal assembly Back Paint containing no plastic parts, Sprinkler K-factor shall be nominal oft white 4.3(62.4), having a 7/16"orifice. Temperature rating shall be Satin Chrome Ordinary 165°F (74°C); cover plate temperature rating to be other colors and finishes available. Consult lactory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. 1" x 1/2" REDUCING l TEE OR ELBOW ii ____ ,___.4 lib, r- 1 2 " (66.7mm] DIA, IMF" A" [58,7mm] DIA — HOLE IN CEILING 1. J CUP 2" [50,8mm] A/AX, ;* i FACE OF FITTING !1 TO FACE OF CEILING 0ff/ENS/ON 4+4 :.�.> CEILING _" (12.7mm] VAX. T l COVER ADJUST!/ENT " DIA, '3/16 3 — COVER PLATE (84.1 mm] [4,Bmm] LH " A5SEBLY SPRINKLER i' 1 --- COVER PLATE: 1/2" [12.7mm] ADJUSTMENT ,...._-- I 3. 1 EHHB Product • Submittal Product: RAUPEX(2)Non-Barrier Pipe Date: 19-August-05 Submittal#: 100RAUPEXNB Category; RAUPEX Pipes Page: 1 of: 1 I REHAJ RAUPEX Non- arrier Pipe A I a - ff8 --- Nominal Article No. A OD'In.(mm) 13 ID°in.(mm) C Wall t2 In. Weight Capacity Diameter (mm) lb/ft(kg/m) Gal*/foot film) _ 261683 318" 0.500(12.7) 0.360(9..1) 0.070(1.8) 0.04(0.06) 0.0050(0.0624) 261026 1/2" 0.625(15.9) 0.485(12.3) 1 0.070(1.8) 0.05(0.08) 0.0098(0.1222) 261046" 314" 0.875(22.2) 0.681 (E7,3) 0-eri_2.5) 0.10(0.16) _ 0.0189(0 2356) • 261066* _ 1" 1.125(28.6) 0.875(22.2) 0.125(3.2) 0.17(0.26) 0.0316(0.3939) 261086 1 1(4" 1.375(34.9) 1.069(27.2) 0.153/3.9) 0.25(0.37) 0.0467(0.5827) 261106 1 1/2" 1.625(41.3) 1.263(32.1) 0.181 (4.6) 0.350.52) 0.0650(0.8118) 138331 2" 2.125 54.0 1,653 42.0 0.236(6.0) 0,60(0.90) 0.1114(1.3906) 1-Average OD from ASTM F 876 2.Minimum Waif t from ASTM F 876 3-tD is calculated based on OD(1) and Walt I(2) 'US Galion TECHNICAL DESCRIPTION Specification English Si Standard Specification English SI Standard i Minimum 4194 4355 26-3 ASTM F 876 Density 58 lb/ft' 925 kg/rn' DIN 53479 Tensile @ 68°F psi @0 0lCm2 Degree of ASTM F 876 Strength 2610-2900 psi 18-20 Nimm2 DIN 53455 Cross-Linking 70-89% 70-89% DIN 16892 @ 176°F @ 80°C Thermal 0.24 0.41 DIN 52612 IZOD Impact No Break No Break DIN 53453 Conductivity BTU/(hr ft°F) w!(m°K) Res. Linear Exp. 9,33 x 10-4 inlfl°F @ 68°F 0,14 mml(m°C)@ 20°C DIN 42328 Temperature _40°F to 200°F -40°C to 93°C N/A 1.33 x 10-3 in/ft°F @ 212°F 0.2 mmi(m°C)@ 100°C Working Range 87,000-130,500 psi 600-900 Nlmm2 Roughness e=0.00028 in e=0.007 mm N/A Modulus of @ 68°F @ 20°C Max.Short- 150 psig @ 1035 kPa Elasticity DIN 53457 term Exposure 210°F(48 Fr) 99°C(48 Fr)r) ASTM F 876 43,500-58,000 psi 300-400 Nlmm2 @176°F @ 80°C UV Resistance 15 days 15 days PPI TN-33 FUNCTIONAL DESCRIPTION RAUPEX Non-Barrier pipe is manufactured using REHAU's high-pressure peroxide method for cross-linked polyethylene (Engel method, PEXa),Ail RAUPEX Non-Barrier pipe meets or exceeds the requirements of ASTM F 876,F 877,CSA B 137.5 and PP4 TR-3,and is certified to NSF Standards 14/61. RAUPEX Non-Barrier pipe also meets the requirements of NSF P 171 and ASTM F 2023 for chlorine resistance. RAUPEX Non-Barrier pipe is produced In REHAU's ISO 9001 certified manufacturing facilities. `These pipes are certified by UL to UL 1821 and by ULC to ULC-ORD C199P for NFPA 13D fire protection applications, RAUPEX Non-Barrier pipe is rated for continuous operation of 160 psi @ 73.4°F(1105 kPa @ 23°C), 130 psi @ 120°F(900 kPa @ 49°C), 100 psi @ 180°F(690 kPa @ 82.2°C)and 80 psi @ 200°F(550 kPa @ 93.3°C). it is compatible with brass crimp ring fittings certified to ASTM F 1807, RAUPEX compression nut fittings, and EVERLOC compression-sleeve fittings certified to ASTM F 2080 and CSA B 137.5. Use of RAUPEX Non-Barrier pipe in heating systems requires corrosion protection and/or isolation by using a heat exchanger or non-ferrous components throughout the system. The Information contained herein is believed to he reliable,but Ile representations,guarantees,or warranties of any kind are made as to its accuracy.suitability for particular applications or the results to be attained therefrom. Before using,the user shall determine suitability of the information for user's Intended use and shall assume all risk and liability in connection therewllh. installation shall comply with local codes where applicable. To the extent permitted by law,REHAU DISCLAIMS ALL WARRANTIES,EXPRESS OR IMPLIED,INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE, I POLYETHYLENE CTS PIPE FASTENER • Itemli Submitted 555 series Tube Talon'., Job Name SPECIFICATION Location Sioux Chief 555 Series Tube Talon'CTS pipe fasteners shall be used where Engineer necessary to secure CTS tube in piping systems. Fastener shall be 100% Contractor corrosion proof and U.V. resistant. Fastener shall be impact resistant to 0°F, po# TAG and be able to withstand continuous temperatures up to 160°F. Fastener shall have a preleaded nail,which shall be rust resistant, zinc plated yellow irradite. Preloaded nail shall have a continuous ring shank to provide a more permanent installation. Fastener shall snap onto CTS tube for easy installation,and shall allow for expansion and contraction of tube with less • noise. Fastener shall be designed to avoid tube damage if nail is over driven. MATERIALS „xi fastener body: High density black polyethylene; 100%corrosion proof; U.V. resistant; impact resistant to 0°F; max temp: 1.60°F continuous. nail: Rust resistant; zinc-plated yellow irradite; continuous ring shank, MAXIMUM LOAD RATING 555-1:3 lbs. 555-2 555-2:5 lbs. 555-3: 8 lbs. 555-4: 12 lbs. APPROVED USES Manufacturer has approved the Tube Talon for use with: copper tube,CPVC tube, PEX/PB tube, CSST lines,flexible gas tubing,plastic/steel conduit, low voltage DataCom cable. INSTALLATION Manufacturer suggests the Tube Talon be installed in alternating directions Lw.. (so that the fastener's nail is on alternating sides of the tube being fastened)to ensure secure installation. Install fasteners at intervals described in local plumbing code for the type of pipe or tube being fastened. ® To install IPS tube, use the next larger size fastener, e.g. if you are fastening I ® s 1/2" IPS tube, use a 3/4"fastener. 1 DIMENSIONS: 555-1 555-2 555-3 555-4 A A: width 0.848" 1.125' 1.375" 1.6875" r B: height 0.735' 0.875" 1.1875" 1,4375" C: depth 0.375" 0.375" 0.4375" 0.5" D: nail length 1.625" 1.625" 2.125" 2.375" 0 c E: hook height 0.468" 0.5625" 0.75" 0.9063" F. width to center of tube 0,5" 0.6563" 0.75" 0.9375" Create Item Number 555-A e.g.555-3=Tube Talon for°G"CTS piping A TUBE SIZE o 1 3/a"CTS oo 2 1/2"CTS ❑ 3 3/4"CTS ❑ 4 1"CTS Sioux Chief Sioux Chief iulanufacturing Company •tei:1-800-821-3944 •www.slouxchief.com • fax:1-800-758-5950 14-08 • Avoid contact with eyes. Splash-proof chemical goggles are recommended. • Review the Material Safety Data Sheet (MSDS) and the important product information provided on the label for Spears'FS-5 One-Step Low VOC Solvent Cement. Failure to follow the above recommendations could result in death or serious personal injury. Listings, Approvals, Application & Use Spe it Flan'Guard' Fire Sprinkler Products are fully tested and approved for use in wet pipe fire sprinkler systems by Underwriters Laboratories Inc., FM Global, and the Loss Prevention Certification Board. Spears° FlameGuard® CPVC Fire Sprinkler Products are approved for use in low pressure dry pipe or pre-action systems by Underwriters Laboratories Inc. Spears° FlameGuard® CPVC Fire Sprinkler Products are listed by NSF® International for use in potable water systems. For specific listing information not covered in this manual concerning Factory Mutual,The Loss Prevention Certification Board or NSF® International, please contact your nearest Spears°Regional Distribution Center. NOTICE: National Fire Protection Association (NFPA) Standards 13, 13R, and 13D must be referenced for design and installation requirements in conjunction with this manual and all local codes, CAUTION: Spears° FlameGuard® CPVC Fire Sprinkler Products are NOT listed for outdoor applications. Outdoor installation could result in product failure and property damage and will not be covered under the Spears° FlameGuard®CPVC Fire Sprinkler Products warranty. CAUTION: Spears° FlameGuard® CPVC Fire Sprinkler Products are to be used in wet pipe systems only, except as provided for dry pipe or pre-action systems in this manual. A wet pipe system is one that contains water and is connected to a water supply system so that the water will discharge immediately when the sprinkler is opened. A low pressure dry pipe or pre- action system is a piping system containing air or nitrogen under pressure that is release with the opening of a sprinkler which activates a special dry pipe valve allowing water to flow into the piping system and to the open sprinkler. WARNING: Spears° FlameGuard°CPVC Fire Sprinkler Products must never be used for distribution of compressed air or other gases except as provided for under Low Pressure Dry Pipe and Pre-action Systems specified in this manual. Failure to follow this warning could result in product failure, property damage and severe personal injury or death. Light Hazard Occupancies Spears°FlameGuard°CPVC Fire Sprinkler Products are UL Listed for use in Light Hazard Occupancies, as defined in the NFPA 13. In accordance with NFPA 13,2002 Edition paragraph 6.3.6,2,"Pipe or tube listed for light hazard occupancies shall be permitted to be installed in ordinary hazard rooms of otherwise light hazard occupancies where the room does not exceed 400 square feet". NOTICE: Local jurisdictions must approve of this exception. Residential Occupancies Spears°FlameGuard°CPVC Fire Sprinkler Products are UL Listed for use in: Residential occupancies up to and including four stories in height, as defined in NFPA 13R. Residential occupancies, as defined in the Standard for the Installation of Sprinkler Systems in One and Two Family Dwellings and Manufactured Homes, NFPA 13D, PG-3-1010 ©2010 Spears'Manufacturing Company Page 7 FOR SMALL PIPE p poyfER VANE TYPE WATERFLOW ALARM SWITCH • The Symbol of Protection WITH RETARD AND GLUE-IN UNION CUL,UL and CSFM Listed,CE Marked,NYMEAACCEPTED Service Pressure: Up to 175 PSI(12,07 BAR) -' Minimum Flow Rate for Alarm: 8-I0 GPM(30-38 I.PM) • Maximum Surge: I S FPS(5,5 tills) Enclosure: Die-cast,red powdercoat finish No,1113555:Cover held in place with tamper resistant screws No. 1113600- Tamper:Cover incorporates micro-switch. Clover Tamper: Activated by cover removal. Cover Tamper Switch Contacts: One set SPOT,Rated at 250VAC. • Cover Tamper Switch Terminations: 8"22AWG wire leads. Contact Ratings: Two sets of SPOT(Form C) 15.0 Amps at 125/250 VAC 2.0 Amps al;to VDC Conduit Entrances: Two knockouts provided for 1/2"conduit. Usage: Listed CPVC plastic piping systems manufactured by Central Sprinkler Corp.,Grinnell Sprinkler Corp.,Spears Manufacturing Co.,and 1PEX(Scepter). Fits pipe sizes- 1", 1-1/4", 1-112"and 2" US Patent No.6,4-71,255 Environmental Specifications: • Suitable for indoor or outdoor use with factory installed gasket Stock No. 1113555 and die-cast housing. 1113600 W/TSK • For NEMA 4/1P55 rated enclosure-use with appropriate conduit Service use: fitting and/or plugs. Automatic Sprinkler NFPA-13 Temperature range:40°F to 120°F(4,5°C to 49°CI One'or two Family dwelling NFPA-13D Caution: This device is not intended for applications in explosive Residential occupancy up to four stories 'NEPA-13R environments. National Fire Alarm Code NFPA-72 The Model VSR-SFG is avanetypewaterflow switch for use on wet sprinkler operation of the VSR-SFC.i. See Fig. I.) Wait 2 to 4 hours to allow the systems using CPVC plastic fittings manufactured by Central Sprinkler glue to dry before attaching the VSR-SFG to the I"male fitting. Select the Corp., Grinnell Sprinkler Corp., Spears Manufacturing Co., and !PfiX proper paddle for the pipe size and type of TEE used.See Fig.3 and Fig.5 (Scepter)that use 1", I-1/4", 1-1/2"or 2"pipe sizes. It is equipped with a for instructions on how to change paddle.Verify that the o-ring is properly union to accommodate installation in confined spaces. positioned in its groove.'land tighten the nut on the union after orienting the. The unit contains Iwo single pole double throw snap action switches and an device in the appropriate direction to detect waterllow as shown in Fig.2. adjustable,instantly recycling pneumatic retard.The switches are actuated CAUTION:Do nut over-tighten the union not,hand tighten only! • when a flow of 8-101 gallons per minute(30-18 liters per minute)or more The vane mull not rub the inside of lire TEE or bind i,1 any way.The stem occurs downstream oldie device,The flow condition must exist fora period should move freely when operated by hand. of time necessary to overcome the selected retard period. INSPECTION AND TESTING:Check the operation of the unit by opening INSTALLATION: These devices maybe mounted on horizontal or vertical the inspector's test valve at the end of the sprinkler line or the drain and test pipe.On horizontal pipe they should be installed on the top side of the pipe connection,Wan inspector's test valve is not provided. where they will be accessible.The units should not be installed within 6"(15 cm)ofa valve,drain or fitting which changes the direction of the waterfiow. If:here are no provisions for testing the operation of the flow detection The unit has a I"male fitting,for gluing into a CPVC plastic TEE. device on the system..application of the VSR-SFG is not recommended or advisable. Loosen the union nut and separate the 1"male fitting front the VSR-SFG. Glue the I" male fitting into the TEE following the.TEE manufacturer's frequency of the inspection and testing and its associated protective instructions for preparation and gluing of CPVC;piping systems. (NOTE; monitoring system should be in accordance with the applicable NFPA The,- I" male fitting must buttons out on the stop of the '1"1 1. for proper Codes and Standards and/or authority having jurisdiction (manufacturer recommends quarterly or more frequently). Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800.325-3936lCanada 188-882-1833 • www.pouersignal.cont I'RtN I'E❑IN USA MKT.111100009-REV P PAGE I OF 2 • MFG.45401062_I I los SENSOR*Th .ce4 14 `° r *141 p Outdoor Selectable- lit Output Horns, Strobes, ! . e and Horn Strobes for Wall Applications • SpectrAlert°Advance outdoor audible visible products S �� �.o , �=PECT � rtIL are rich with features that cut installation times and "`"=''� 5 maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, •Weatherproof per NEMA 4X,IP56 strobes,and horn strobes in the industry.With white or red plastic Listed to UL 1638(strobe)and UL 464(horn) housings,wall or ceiling mounting options,and plain or FIRE-printed • devices,SpectrAlert Advance can meet virtually any application •Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151°F. •Field-selectable candela settings:15,15/75,30,75,95,110,115, 135, 150, 177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes,and •Automatic selection of 1 2-or 24-volt operation at 15 and 15/75 horn strobes for wall applications include a variety of features that candela increase application flexibility and simplify installation.First,field- Rotary switch for horn tone and three volume selections selectable settings,including candela,automatic selection of 12-or • 24-volt operation,horn tones,and three volume options enable •Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. •Rated from—40°F to 151°F • •Universal mounting plate with an onboard shorting spring that Next,SpectrAlert Advance devices use a universal mounting plate tests wiring continuity before devices are installed for both wall and ceiling applications.This mounting plate includes Plug-in design with minimal intrusion into the back box an onboard shorting spring that ensures wiring continuity before • devices are installed,so installers can verify proper wiring without •Tamper-resistant construction mounting the devices and exposing them to potential construction damage.Once the plates are mounted,all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults, Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)[hat accommodate in-and- Agency Listings _ out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING " corrosion.Knock-outs located on the back eliminate the need to drill holes for screw-in mounting.Plastic and metal weatherproof back ME boxes come with 3/4-inch top and bottom conduit entries and'/4-inch LISTED •••" �soo-iai3 ia�(au °or>nr,6es) approved r2`-'^"'"9(homsirohes, knock outs at the back.A screw in NPT plug with an 0-ring gasket WI I lchimes,hMncnnheL horn,l APPROVED PP enure wabes} sin ioi¢dnnrenr,Alert crnb^s, 1,1;3•7> MFA457-04-F 7135.15,1.1N Thor ns,rhIr ) for a watertight seal is included with each back box. 1 N POWM. icy 25' o, q6' lo' - kS OEMVdAr___..____-_,---7 i & CA�3LE �" STOPM SFW�F PIPFS o'ELEVATION l; SMIrAQY TVkl?, 90' LEVAr 7N 7OWN5PO T 5117&W� • ►, \ �PkOPEPIY LINE 100' / II: . r'''' 1 a'...V,5 i- - - -• • - Ls\ r ,r '- ZJ�— 1 `' rr, • i' 11 11 E 1', tE Sz JJ_' [A /y� a1 ill L fit le 'r _l� r TI �� 1 E i'�I.. ,__,�,.,-_-._ • 1l-£i :11 l ,„ ____ -l--V irr - IIE_I ! JI Yu , ., 31 1 131 '11�... .2111,1 / r_-, ,'-I I 1 it 3I 11 - 0 ' lM_= JL_a01 _'J 1 i i11 a11 O I I ,r l\5 F 1 1 , ( I I Ll Li J .. .,,_— 'L \ H 1 Z f_JJJr 1 1i i i'= E1 _..:;�..� 7 Ire � `- ��« {� {.�{{ _il i1L E i '1 'L 05 I. r 'i1 .0 1i--- �L--d>•-...._ -,IL PAII0 =—=f sL_e=��'' 1 _ n O h ! An li`\.,',{ i I 1 1 O , 11.E li el > '� r, sL1 f I i 1 >AY_ '.>•',. 1E 7 4 i r�-,j IE r3 al 44 ►,� F 1203 5112:�T : "'3 r-r. I •3_, lie_ 1 �_�_, 1205 II-, 511:�r1- �;_ I - 1u11 ;Ir�� 1li 1 1 I Lv J, 3 Ei 1�1 Y ,� F�� 1 I t il��_hi ..1�_ I\ I n [ i I I f}r-yl I 1 ,I 111 ,, IIrl clt'T1, II 11('__J I .' I I 1 i r-e L_..y A JLJ II 1 L f,- ll "f% 11 __ 5�_=4.._y' -:a-.i .�= - __--'J If 1 --oiT`fir=7,�-�-i1 11 1 rl�l'£�:';�I. 1 I ;_-'- JIl �. ' L -�'i�1i 1:{��---t-� •y'. `Ym 111 i 1 11 1_'_F� II 1 i L____'�L _7S __2'-_'_` _tea'. _'1 1--_ 11 yj �"a �1 FL IA to V� 07 ►I4 f7� rf% r43 ►ny1 r .- fi► p m far fi`r • ID •3i1 0 n .A fi. �. fi fi N SIq�WW K r \ \\ \ I I. ,.... .. ` �' ��� �t4 h '` ,.' Ad v a♦ ��j PAWING 'fit wa 1AV fi► 40 fi. i► rtm fit fi p No 0 1i� 0 Ca �PRK 1`l9.HA-1' __ — `\ Ili_ £1 _II} _�? w r 1 �.—_ —�IIi- i,rt_ V1 L -Y"'�=31Ed��_r_..,_ I — �n� i I' ,._..JF11r 1` me �l — I I__y y,%F:, I' r LI it II IE c..__ F 1 11 FF '____�`_1lL_... _ 411, rirt� Iii+ LjL_j, 1 f Ui 1/1 Is1'.rJ ���\_�,-'- , I { IrT,a 1I i'"?71 r-- Al I. I 1 1'1 L H i- -1 'll� I y''L11 £ 1`� I l i 1 ' l Nt.JE >__J / .11, Yc_.rjJJ_ !ill Il = M k1 �lsk S � I } . _> I �� HD I211 I�0 5T � 1 1 I 1 11 I 11 I!U;r _; Ia • f. 1-! ••__�i fry � f-:1T = }~_..B_�.._ I I : , 11 [V 1 1 F i 1 1 :•11 ,I L--_J I , i tlqc1 }j �3 II s� '1 I i`\Ili(1 ° :1 L---1 1,EIl i1 0 f. _J E �- ( .� r } -7 / L__ __ EI t V 1 6' IL_ -- -_ ,I PAT© 131 1 ! it t ft } JI �« }III 11 rF';N,Lr e I.i F..• ,Sr4� H III ,' %IIEI Ya✓ N ,I _r' 13 1 '1;:'I L"" 11 �� 11 .),.!'1' 11 L__,_JL_LT'�::.0t 1 �; E !'�I.e i' 1 -- iri f r u -,`" __[KJ !n +l n ° 1-=---:t_---11 r 7;e. _r,.rizm} r'. r rf z -! :I' ro7� O [I I '1� f�� 1SI ;I �I I I 1 : erl�r III it {r i11. aL' __ 1 I 1 1 1 3 s i 1 I 1 rL _la :L______ J. li 4___q L_J'1 I' a E ' 1 • i I l' o Lt ____ _ J: L_..._J_ 11 e1 1 NE , I i . _ ' <_� st»-r,�..�ir•']�s F�.7'iz'a-tr-.5iss_saa.r O 4 " ELEVATI N [ \ -- -- \ - ul •� �115ropM swF�pier 19°"51'01_tr 1 120714th 511',) -1 Lovv�R APAerMENT I209 €nth STP. T • ` f0 A'P12figNI-P001 E / d► • �`�4-TorI rTY LINE 100' ''� 6011 ELeVP.TION 10' i 25' gr _ qb' i 10' k CITYWA7%MET1ip5 12MWINCI INI2�}(; II^al"pr�eRsze-- c�:ls3i;z°' ccffrVI� Cof18 CXI5TING 1. 517E FLAN22"x „PA P,51lf---5-CCA 15>/1r7",I'(COf'a @ 200%) At717 2 MOF 2, NQ�M PI?OPEpiY NLf VRT1ON 0. 1207& 1209 C LI NATIONS LOT AREA 50.1 T,- 8998,2 51 PLAN 2. NO;20 ELEVATION&FLOOD PLAN 1. 1207&1209-MAIN&LiPPFP FLOOD pLAIJS 13ULi?ING AMA 50.Ff.- /1269.1 II. 2, 1207&1209-FOUNr7ATION PLAN PCPCENT Or AI:EA COVE C- 47% b� �p � 5. 20311203-SECT10ANAL& 3IKE WALLAN:, �, 1207& 1209- C PLAN 5. 1207&1209-5PPE1 FLOG':FP.i1MING PLAN& r.00F PLAN 1203, 120�, I207, 1209, 1211 WTIQNAL DETAIL I1TI 131M—i- NS51I7NCF5 b, 1209-ELEVATION 5, 1207& 1209-MAIN&LiPrl p FLOOi;513PACE WALL LINE PLAN 5PFINKL II & FIEWATNR 7, 120_9-FLOOD PLAN 6, 1211 -ELEVATION&FLOOD PLAN f3JI1,17Ei r0v ?IrV L t7IMGN510N5 'A'CN,#. 1'S5295 8, 1209-FOUNDATION&POOP PLANS 7. 1211 -FOUNDATION&POOP PLANS (ON5TF/IL11ON rOcoMFLYwmA-L. 0 I0,fl - r"-nn,1AI P (3pArr Vt/A1 I I lklr•PI li!SI P I711 .a=r,ri/)n 1 of n r l7nrr lhlhl I 111.11;ni a I I 11r171 CrLTG o G*r7.-"UG1 1T1111 I7IkI.I rl.S lee •-,,-.,...-.,, .._.,_._.- .--• i c- . .- . Ni .•-- .-,-;) .,, i.„.t. \ ,,,/) --''' rr% I '') '''.----‘-''. ' ----74) 1 , 1 -- , i •01,-.-, , 1 • • -: N -..-.' ) •t '\-,,, , - .\ 1 _,'- ,C... ' - •., x-, c ..., _. .. , .. i r \67:J t'4 8, • t.::: ' 4- . i ,.....„/ '1•-.)- I-,"Z ( (.). 4.-. ..'i .7-'.•::._ ..„..... , N ...t, ,, .,,_ c' ,. ,, ,. . . . ., ,,,,, i• C.,::: :1:;:-..;..'-'- 'I'''''' ' 1 ..z , ..- 4 ‘,-, , . -----__,__.------'-'-- - -'- ' \---.• tL.'.k-.?-It--.3 - - __ _ .__..-- " fr-- 1.,..• 0 o' ,. . r-•.?.. ,P • 1 N. ..Z• Vii.-0. ,, ----„, -7.,:11-'. ---, C. ....?4••-.... ,-.) '1"-C'1. ip-4'...-.- !.••' - - ...._ , t•----, • „..,_________A 1 -.4,-. . . k ..... 117,A, 0 F • ( 1 ..„,..4 _ ,.., ,, ty ., .- 1 4. • • 1 - Li .! ''''''N'A-Nr."3. ''....• .(1') ''1,r :PIZ , ) F41 1,1-‘,A •C:, ? 'Li, ._(11 . r , ..., 9 ,--4.- p ,,,_,,P,_.{.., tf...,/ I ....f.77,...,. , __________ . i 0 • (-„.) . .------) t, 4,,___ 4 f, ,......,...... i ,'., .s.......›. .,- , '1',, " k,...k.„.'Li_f'15.se 4'''' ' )'i• '., l'1.4 f.k„c''. 4... . `_•.1.i.- .4' J .'-- (r----6 . •_ ,, r .,-,j• ,-('':". ,:- ,..A.,. , ,-.. i'•-• (- -C-' • _. r:-,,, t; II". \ j ?„-'t. 1.,,',.'•. -k, ''' , '' '.. . . ,, .---.)\) ', k - L, • --... - ':1/4, . ,,, • ., ---....-_. itri ,.... ...,) ,,,, i„,.. 'i' ) ' . _ k -1 \,L ,. i'.!.._i' • . '.:' 4,'.., . . . A : T:i .•I':.-..: • . ,,r. ty , i:-.:---F—v— -, ,...'2,,,. ! k • '''' C.)\ ) i,,,,,2' 11 I I\ ,,..,,,,, , i c ,„ ,,,r,(..,,,,,.,:t„. ,..„..._ :, 1 4 I. 'i ) ' \ ,...! ' , ,,r, ,.,,, ,•.:,..,. i ..., .c• '' ...k, ,,.“if , .7,,,.. ., 1 • tr'' kc‘,..v.1 ,?-: k• 1 ..1 \S ti 1 - — (Vet 4' et-'''''7'.-= '''f '':-'' l' ''''.-- 'V --6:' -.. -,, ,---- ,, C.____55:',''"...,,-. , , .,-_k ---, ,i, x.,.„) •', + '•,f,),'i• . ' --•- i ,.. , ,,,;\— • • i v -..— : ,-----...., . V, , (1, \ . .?......,,, p- 1 ,......\ i ..).1(- k'. .,-,,.4 ',d k ... .' C ,, -5- ..---• '' ' • ..,..-,,i ":„ . i., ,.., , ,.. . . , 7,1 -.,.. , . ...__. ....— — • '----- , • sA _ — fir.- , C--, -\-' ' r I' . - 'C 5 ,,r tr--- (1.',4- „.t. \.,...., ,,.. ' !/ fLi/LAJ • .J-V LA t...4(4..-1-71 iC1 1../1 lac) 'AtJ I I/YWCA-4 7C-14..Li VIVID III l'cl 11C.0 0 A.4S7_4-', IVA/ I 1V HIM AlChNO)01 NOUJIAI-SNO 66Z6c '#11)AIJ NOISN'10111 1-W A4c:I1A GI Ncrii% 5.1.1\1 1)\116-15A1 Jllai-S '1171 coi 11N\ici INM AW,‘,.;i0 aNN?lalli GMACJV NV-Ici C100-1 'S SNOIJA/A111 , - S.2.I ,..--NimIMMmimmE 7 1 (%coWOD) I 7/iSITd%- ZIth k 7 fm( 001aAdO» 1g/I(1 Z15Gi GI I r ii iom \.. _...) 1:10:3 2,01-1iNV LP Ill/1 III I -ZW: ndopac V;)/ a 6:10\1 l ' i+4,r IL. JM 0 -,111.)1 • 1 5J-111\11P v‘Nii_tjw.,...(0)0 NVld ,010' . 4V0'4 30 11/4-1';'.;19(.11 •:.'''::,, ::"-':-,-.[•:1,._---U1,15 lltiVcIO 51,1111VN ?,d11-INNA I/-9 ' `,[- '0 V,"%W 11A11 r ,....... . 14,-...,,..,...[0. Gf1J-5 kail 0.1. !rQ,•-•.'''''••4' :•::'4.14-2--- .1A11VN 9N11,41.10ri Sall; •II.Z CZ) I .6Z --:r :1,4-..-.--:-.1-.1:::•:•..,•, ,,,:, .7'liZI '.,:11).'N PY ,.!:.," ."-:.•-,---..'7,14.--'.`:•:•::::: TIN/1-6 '1.4::,',...;•••..4i.:),:::,•:;,r.,1,. SAINI:AIONIK/JJ- 1'.1::••;;:.:::::;•11'r,,",!::::,k __...-00W,1,1..91/4 111N 2.1-)101101N1 Ild 71:,:•• ••••••••,,,,i'l•;'f••-•::•:":f.t -:- I 1 '411.-1.;:;:-::;:..!1"1.•.::.:,..›.:,:•: r .. .19-19 .01 .'• .19-19 :•-..1-;,...•:••4l2----1,:..„4„,....4.: Zli 7 / I irk1-16•— - -,9 -'._ _ _.'g-p,1 lip,' .......---- /-49.. -. H:'"I • : 1 1 %HMV ,;%)VIVA 1.1-Yld JO:1-al -s,-. •••,,,,- . 1 ..7.ri,Z;11 gq:" 1 ..\•,.1.50c1 14.1"747-)...1 11.1.0.W1-15 I Cid)99 1 1 \0 AIA',-1 -,-110S \01J-VA'1'- .1- V. i ! J.JI.A0) I , .. ,, xoc„,,,,6, dm. I I r' I . .. .1_, , - r__J —I ° W:ald WO l'101'OZ s4 s, • '1, .- `r r ,T. ,; , , -r -r•-. _ ,10,,m I I / 1 „ ,___,, zno,P MI- 1 1 I! I I i I II, i i 4 i j' ; i I I - I1N I-lain OH i r I . 1 l'I 1 ,. . . 1H 11 III = ,,) I I 1 1 11 1 I HI VOID 31 ,.)-, -T \ 1 ' 1!.! I : I: : f _. P I IIIF+ I I II I ; I Ill i 1 I N11/111 ,rp A. .,, I - IMI . _ J., NIN161 i 4.)''' ;,,t- rt'''; ; t4•';'1;: . 'TH."; 0 4'0! „u_,; '''f ' '' I I; ii ,_114i1A1,11th fr.;.-F'I', •• ' . :,•,_,, .'..T l'• qA'... -,In-I-rn.rrn-p. . . ' I - i• 1 t 1' IT- 511-Al Wk%iall'Il JAL 1"1 -' ! E ..) c•DK' AY. - T" ' -:I' -r"1:;: ,u, •:•• • 111.:#-L. -- t::r.r.., ,,MT i': Fi-pr''' —,_..) .:: -:' : 'il-1:1:17 .' 7.7.4,- 1 , 'i i i!., 11 L ,, I ,, '.!_i 1 I I I • , : ...x,•• h:rti ,,uuu A:H;,ii,(...,•?......:,,4L. 1 , ); ,________,_. , , , j_ ,,,.I. 0 INGI '5.)...).,91 6 tOZ•-..., ! r r —1.' -1' 'ii;LI.1 • , ,Ji,,,,. 1, . IIIIIH4.444 -I-4. . 'N dit ,,, -t..,... -- 91 55D2ri 7111•V ' . . ---- ,. --- • . );_iy, •, ' pi• Ihrft,L,'IIttl.'ir.I..vr 471`-',, ri 'Mr! 11,10 • •:•••1 1-. ,.; 411 Pi' -itii gt.111: ••• l'',,,a1111! 1 , •• 17-Fil-IT .. - _,„,t,'n',.' il-trt • • , ti.,.4 o:I. ,,,,,J ." ,.. . fig,. ,I Ellik-. -• ' I ' I 1 ' 'I II T•' ‘ ,.)i •ri,,A. _?:.t., . .t 14'. ..d 6rri, I..,-II1 rI,' .0' -,- Fri. ,' . - i . z '-----'-,y,-'6 9.-Nd-Id„ I 1 - ,C- - 14 . %:ft.'.-•'};I t. ji,j-,t • 't'.4t'.l . .di•-• n7 . .iii..,J,1-frnr . 1, , , .-. 1 ,, c 9 ' ll : Kil'''1 NINP41J 11 '''' — \- ](,...ii.. '.7 . I.,A, .7.,..)1-..,,. :=,;), t•,.: • . . -1 .t Li'i•Latni 'h. . .-r.,:t1 t.:ii .0,1,-.N',, r1...-M,.„-r,444,. .,:,„,, ,,,,,,,41,,„.Mt.111:0.11k,li.,,1,„".',.'rl - 1"" ; . ; a .11. ',J.; i. .-1 = a, - E - .,.= ''vj II , ,I, ,... •k)NorD.0 ! - - * - 1,31- 0100i61Jj 6_ c° I c"). 'I (--)I_ID;P t —0— OVA 51 ON \01VA'1' IS'W — Rtv6 ,011,1z1/9 ---iy - ,•„, ,,o-,, , , ,,,,,...,..,„.1,— 1 . - - 1-..NI- ! 1111, fl'' 1 TkicZ'01, . v.- NA- ' II = i .--. . . r -L'i -1-.-' r '7 T T 71 71 r -• N i Jgg .2,C.fer) L_ - mr _ allI) k- U•-•tral '..____.: I I ; : I' ' k 1 1 I II : , , 11 t,-4,11(115 1 1 1 :: 1 1 :I 1 1 1 1 11 . , _----•: _ (WOO U 4,1-‘4`g "-IVY Pj'P.z I' L 1 1 1 I F ' ' I i 1 -'': 1! I 1 '' 1 11 1 [ 1 1 F L i II i ,,G-•,, !'"---4- ','11--,,r I 1E ' - 1_,... ,.!1 i,., _ 0_ Z 7 . - _ -d:',W -.' AT'lal I I— --in%cIdl %I-1d-ACEIV1-1 ._.. . ; : •'?—.5 ' .57., ., , lit' 4 -1,1-,! r11. .•, ,,„: ...,,,...„.,,,. .... .",., . . , ..-..., • : I:t • ' .. t,,titt,:;,-.Y'' 1H",'T . ,'' ‘•:•,..ft-t-i' 1-1 ii l I I -li ' 1 •••• IC, ' fill il iL .--qh., i , ii lir I FL1_1. .n,th'..IH'44`1 PI,.,.: ff t.i'n .1Lri`II:ri.rr . 11-1 (r-,,,,i7r ' ' !I V!. ,I.I. .. P '-..."'-'7;'::.)...1-10111 A,T4.• ."11PT ' H I.i., li I Fr', , 11--;Li' EI7....."-..'I.. .. .a.V.T ,17.1.1.111.44.i., .1 PY 1:::'Ir'k? - 4 -:11:7' .1:1,- Hy :•‘...,. ,1:1"1 1...:-- 41112'.7_,1173 4[11Y,L71 ."; , 1; ; 11 1 , ; ,. 1! ;I ; y..X'" '' .;7111. Tr" ; 1.1_1 ro_Hi;;:i,.1 'II -1-"-W- ..`r • tttrr': ttn--....,„*. . •-1,-.FiYtrhr,11137. . .• _I 7F 1•1'L11•1...ar...ri.•„. pr: 51"..5.,1- 10/-110,H. ,' ' 44'd 6'1 .,.-L,i ,11. ;!. 1j i; F1-Tri.?...ji.r.,,....j-,b. ,,-, „ r, D.,,r: ' -:-'[i, -1';1 j.li,1'4::L. 11:::- 110 • •fq . ,'. d A ir in -.-iffi N , 41 ',ii_,',. If: :: ji 1.i„,:,:, :,,,i:LL:,:_ .,_, : ::ilii;':; •';',La_:„..:'j_,:,. L_L,1. ..;..:2:.:u.: , LI '-ev,- 1-J (3c ‘c q J\:. %;-..1 ',. k,%-- ,--, i ',' ----)c. t-1-- — __T-1- 1_ 3 I .-J-,"4,Fit'v--- ,. o I ,4%),) /I, c., ram.- - ‘\ I ut Is toyiki\ ...4„/..2,,,--- I 6 otI ,.47. , 4 lir I ,.5 lilp (2-) t-r;› 1021 -- 1. 1 = �f i , , 0- Ir.? 6 -.-'- -iP , 1 i \re21)%>bc /* ,. i. 1 bj1.\ P\-tviivv--- IN, Fv.is ...,"\,1 \--file\ 1 12_ .-3, Ros, 1 -2.m7 Ric) LP* j - — . Pt --t.c ,r L4 )V\1 I � I it ( fit;. � " � V 1 ' 7 ►' ' A 1--- -Q, rrft-- 1 1I.t S p-1.+2:_s NN ( l'-ferl tLe kij %'-.3, 11"'.( \01 ti 45.,'I L.10.t , 4 \il) \ i L______:::4t. t...... 1 0)04'0 i ?r‹.____ --2.j5. Lis ,,,,, i 3 ______ ______„) 1\ 1 • • - -- .--- . 1 ' tpki-u3k4, 4'\ ',a NI f+js , - . 1 � r ,----„---___ .• ,,,,, _„„ _ ,, ,, , , ,,: y2.1 ___ _ .1 ' 3'94 \.,;, '-^ N --1 Z 71 1-- ,\,,,,,, ., 12 V,...,1/ . 1 2 lellfr 7 1 \-2_o _7 '1 '1 , - 4\ 1 I I f ‘ 1%) I C-6NeNk \ticitty-- 11•21't \ 2-41 9 - 3`1 r 1 tAJI\D use. t ' ` , - - . '� l . c. ) k 4 i ..---. i 12.zkS , tz. q.1201 E I 1=f- --- . I 1 ••, t-(t__ 7(--. _____---------- 1 _ _ 1 II • , ---- ' 1 T - i b4'1 .\ 1 - 1 1 • D % s ' I, .. ..,,.._........._____:_____\,raei YN-- . 1 - i I 1 .,_. ! B m ikio/N , - . k i , I -3 I ` i 1) 1 � I ; , 1 t . - 1 )263 1 1 V ji. I ) 2_ 1 I 1 , i � 1 . ` 1 14 f a i / j _ i I i ' ) - - "k------V 0 s i-p t. Pl- ) Vk-‘,A ÷ - - <;_ - 1 1 ' , zz 5 •L -in, •2___c -7 / c-2_,0 q , , II ,e, ~ ` f e.3 p.) -i-C t\4-1°.4 ra 4.... 1 ' ,---; ii_ ____ _:-:-/-1411 I I . Dilv-)Nezir 0,3 ild-• !' (N.73 B 1\ fk__&\A6r.--- _Si . iz1,-- v 42-1 [r3 li 1 i r 1\ -1 (-0 S- - - _ ). i, . _ ' 11% if\' -__ 11 I ) -13 i 1 'I I 1 ti a 1 1 S • 0--- LJ H - 5+ , v\i e 1 I �t 1 i I` 1. MOST HYDRAULICALLY REMOTE HEAD ► J1EAD # GPM PRESSURE REQVD AT STREET 2. HEAD i : :. 11.6 GPM 26 PSI 6i; 1M� ifrr.-.,a •- =-1 1 " HD SYMBOL MODEL # K FACTOR MAX SPACING ~ Ipiliq , I{: RFC43-12 SIN-RFC43-RA0612 4.3 12X12 illi•WziJ ' RFC43-14 SIN-RFC43-RA0612 4.3 14X14 r �,,,,,,1 °� �' 0 RFC43-16 SIN-RFC43-RA0612 4.3 16X16 -all °0•-s~ - 0 RFC43-18 SIN-RFC43-RA0612 4.3 18X18 0 RFC43-20 SIN-RFC43-RA0612 4.3 20X20 Temp 'K' Sprinkler Max.` Norminal Minimum Required Sprinkler Discharge Model Orifice Size Rating Factor Spacing Distance Single Sprinkler Two or More Sprinklers (in) CO (ft.) To Wall Flow 1 Pressure Flow Fa. Pressure Ea (ft-) (9Pm) (Psi) _ (9Pm) (Psi) 12x12 6 12 7.8 12 7.8 • 14 x 14 7 13 9.1 13 9.1 SIN RFC43 1/2' 165 4.3 16 x 16 8 13 9.1 13 9.1 18 x 18 9 18 17.5 18 17.5 20 x 20 10 21 23.8 21 23.8 I I I 1 NUMBER OF SPRINKLER HEADS: 07 251 e -. 51 - IM�II I_11 I II I WATER SUPPLY It Requires esInsul the pipe A'�� �' It Reqclrea Insulation 5e moved SUPPLY allow heat from the a sprinkler pipe toee 314" METER space below to transfer into the • attic space and keep the pipe STATIC PRESSURE 60.000 warm. / 1- '1 - ---- - III-.42I I t , RESIDUAL PRESSURE 52.500 AVAILABLE FLOW (GPM) 30.000 f{t11.II I'-7" TOTAL PRESSURE REQUIRED 37.924 I- 67- TOTAL REQUIRED FLOW (GPM) 26.000 2x6 ' 16" y� TRAPPED AIR SPACE - 1 ' X11 L5 SAFETY MARGIN (PSI) 16.321 LBAITINSULAIONTENIEO OVER PIPING SAFETY MARGIN (GPM) 4.000 TENTING - WALL - --, "- 1 1I CLOSET LI 1 E ----IN ,, . 1 A V. i tC1 BEDROOM 0 ) n n in II ti Er CEILING L.Y 2 ' !� _ rl.i Ir1�. i 11r�9fI�;LIiFLE - -- - tritt. - , IP z _ r -- 4 _ _ fir' (30 i 1 -N: ., I RFC43-16 RT04,Nii j ---n r 1.3-12 _-- `- --IN H'4 1 H-1 ------, Q F tu _ 1 L�4 1 '' r BATH 1 N ' ti1 l_^ "��` fi I 6'CEILING I ,,�q�� $1 _ / � ' I I -IN w r __=�, ___--___-, r _-____ I r; % CLOSET j W' MANIFOLD EXAMPLE �� • I, - 1 --, I . --� FBI' L =.:,-16S1. 165 _ 1 - 1.1.f- - -- - \ ! l s f 1 1 m4-5TT 'tiidr.hr4LJ8 -I- PATIO ' i I t I I OR III"--"f... 1 l I I DINING I :1.- II;,1."1 -:. :'a?.C„ly� 1 I X I W Q I N.G 1. B'CEILING Z , Ri ELEVATIONS-CROSS SECTION OF HOME pi c rJ r %e I I I I ��Fw , { Uml "g 4 1 ! I H N 11 1 1 rnr� I- !IV!" I I .=1 IRF 4 -1!ISST-16 I r 1: 3-16 11 III --- Z 0 >0 W -% - I01-1.7 ;�I. I I . # -, Zzz O O I I ; EJ_I I I - 109 FT uj , ,w - 0 LIVING I KITCHEN f,t'^h I l LI,J Q Ili 1 Ir COLNo I .8'CEILING I L,)�JI 11 �• CC II0 Ce 0 I 1�T1 • ri �f 1 � ~ -� I wa p � � I MAIN FLOOR S.0 - 102FTCO - - G �1112 Lt 1 1, 1- -- - j, 1_ J 100 FT uju j c.,) ct - O I 7 \ (� /f �� iT -- HV? ILL; `,c W CC Z _ � - 1 I L �__�__, I AMP I I O O CoN 1 1 I - CO p Ce 0 ~ O < r1'• t,l 11 ,.r I 1 �./�) rCrHI fy0 I 1 a Jr A AL i Q a , I I � VI 1LLI el- -- N 1, 1 • 2 Z I!�II_!.II 4x8 . . I -_ - cn r N MAIN FLOOR PLAN • LU • U-I m W Wz ce W H < g 1 9limn 1.1:5: CO 7 c l >61 CO " ' I- 0.% 1 W rl� R ! 2 34 • L� J J ion 0 r- 0 kZLIflC M Z Cn I_- i33 D1 c N Z Ce L) x - r� r-. W tiin OI- L . .u.l W EaJ � 6 N. in ua a� , • S 3 a Qi m - J I JJ W pr (l 4' _ MCe �� ZX N - - Q ,J CO ❑ & lrliaa CD �' Q V r U- aco RESIDENTIAL PUMP - NFPA 13D 2010 HANGERS AND SUPPORT-CPVC FLAMEGUARD 1'1PE GENERAL NOTES CONTRACTORS INFO, OWNER STANDARD SYMBOL KEY HYDRAULIC CALCULATION SYMBOL KEY M ti 6.2.1' PRIOR TO SYSTEM ACCEPTANCE,A SYSTEM UTILIZING 2. PUMP MOTORS USING AC POWER SHALL BE CONNECTED TO PIPE SIZE MAX SUPPORT SPACING 1.HORIZONTAL RUNS MUST BE BRACED SO THAT THE STRESS 5.RISERS MUST BE SUPPORTED BY PIPE CLAMPS 1. THESE HYDRAULIC CALCULATION'S AND SYSTEMS MEM 1" FLAMEGUARD (CPVC) PIPE SPRINKLER HEAD WITH HEAD S.0 SOURCE Dla INSIDE DIAMETER OF PIPE 0 -CC'► COI O A PUMP SHALL BE TESTED BYOPENING THE DRAINITEST A 240V NORMAL CIRCUT. LOADS WILL NOT BE PLACED ONA FITTING ORAJOINT. OR BY HANGERS LOCATED ON THE HORIZONTAL ARE DESIGNED IN COMPLIANCE WITH NEPA13D WILLIAM MENDUM CONSTRUCTION WILLIAM MENDUM CONSTRUCTION H NUMBER, SPRINKLER TYPE M C CI) CO CD CONNECTION. EOM5-1/2 FT SUPPORT SPACING IS SHOWN IN THE FOLLOWING TABLE. CONNECTION CLOSE TO THE RISER.ONLY LISTED 2,ALL INTERIOR PIPING TO BE"REHAU"PIPE UNLESS 1.5"' FLAMEGUARD (CPVC) PIPE H.1 HEAD NUMBER C-Factor INSIDE OF PIPE SMOOTHNESS 3, ANY DISCONNECTING MEANS FOR THE PUMP SHALL BE HANGERS AND CLAMPS CAN BE USED.VERTICAL OTHERWISE NOTED. BILL MENDUM BILL MENDUM `:rC43-1€, NUMBER &COVERAGE t = m 13.2,1.1 THE PUMP SHALL SENSE THE FLOW,TURN ON,AND FLOW APPROVED. 1'" 6 FT 2,WHEN A SPRINKLER HEAD ACITIVATES,A SIGNIFICANT LINES MUST BE SUPPORTED AT INTERVALS TO 3. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'0" _ DOMESTIC PIPING R.30.A RISER NUMBER FT FLOWING TEE I C) - N crO o toWATER FOR THE REQUIRED DURATION 8.1.2 OR 6,1,3 REACTIVE FORCE CAN BE EXERTED ON THE PIPE,WITH AVOID PLACING EXCESSIVE LOAD ON A FITTING PER NFPA 130,REFER TO SPACING CHARTS FOR PO BOX 1656 PO BOX 1656 • • r CO o) U. WITHOUT INTERRUPTION. 4.A METHOD FOR REFILLING THE TANK SHALL BE PIPED A PENDET HEAD,THIS REACTIVE FORCE CAN CAUSE THE AT THE LOWER END.THIS CAN 8E DONE 8Y USING MAXIMUM SPACING BETWEEN SPRINKLERS AND TO THE TANK. ® 6-1/2 FT PIPE TO LIFT VERTICALLY IF IT IS NOT SECURED PROPERLY, RISER CLAMPS OR DOUBLE-BOLT PIPE CLAMPS FROM WALLS. ANACORTES, WA 98221 ANACORTES, WA 98221 3/4" REHAU PEX PIPE I T.30 TEE 1 B 1 BRANCH OF A TEE 6.2.2 WHERE A PUMP AND TANK IS THE SOURCE OF SUPPLY ESPECIALLY IF THE SPRINKLER DROP IS FROM SMALL LISTED FOR THIS SERVICE. 4, THE ROUTING OF THE.TU$ING SHOWN ON THIS lij FOR A FIRE SPRINKLER SYSTEM BUT IS NOT A PORTION 5.A METHOD OF SEEING THE WATER LEVEL IN THE TANK DIAMETER PIPE.THE PIPE MUST BE BRACED AGAINST THE DRAWING IS INTENDED TO BE SCHEMATIC.THIS 1" REHAU PEX PIPE pie R STROBE o P.1 PIPE N UMBER 1 R 1 RUN OF A TEE Csilw 1 112"" 7 FT X VERTICAL LIFT-UP WITH THE CLOSEST HANGER. rr'V r3'f tit 1 fti [] a I OF THE DOMESTIC WATER SYSTEM,THE FOLLOWING SHALL BE PROVIDED WITHOUT HAVING TO OPEN THE 8.THE RISER SHALL BE SUPPORTED VERTICALLY DRAWING SHOWS SUGGESTED ROUTING ONLY. SHALL BE MET: TANK. WITHIN 2 FEET OF THE CEILING OR BOTTOM ALTERNATE ROUTING MAY BE USED,SO LONG AS PHONE (360)-661-6396 PHONE (360)-661-6396 2" 8 FT OF THE JOIST. L.1 90 DEGREE ELBOW PT PSI TOTAL 1H 1 SPRINKLER HEAD 3.ALL INTERIOR PIPING TO SE 1.5'SPEARS CPVC. THE SPRINKLERS ARE CONNECTED IN THE _ 1.A TEST CONNECTION SHALL BE PROVIDED DOWNSTREAM 6, THE PUMP SHALL NOT BE PERMITTED TO SIT DIRECTLY SCHEDULE ED FITTINGS AND PIPE. ARRANGEMENT SHOWN. EMAIL maggimmn(Storage@hotmall.com EMAIL maggiministorage@hotmail.com I OF THE PUMP THAT CREATES A FLOW OF WATER EQUAL ON THE FLOOR. 2-1/2" 9 FT 7.MAINTAIN VERTICAL PIPING IN A STRAIGHT 5.ALL PIPING TO BE SUPPORTED ACCORDING TO D.T DOMESTIC TEE P F PIPE FRICTION 1 L 90 DEGREE ELBOW TOME SMALLEST SPRINKLER IN THE SYSTEM.THE 4.SPRINKLER RISER DIAMETER TO BE 1.5" ALIGNMENT WITH SUPPORTS AT EACH FLOOR NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. CONNECTION SHALL RETURN WATER TO THE TANK. 3" 10 FT LEVEL,OR AT 10 FEET INTERVALS. 8. THE PIPING ARRANGEMENT ANO HYDRAULIC T.30 • NODE (TEE) NUMBER ; PE PSI ELEVATION Mil MANIFOLD - CALCULATIONS ARE PROPRIETARY PROPERTY RISER FLOOR CONNECTER OFE AND XFIRE RESERVES THE EXCLUSIVE RIGHTS - AND RISER NUMBER QA GPM L.2 90 DEGREE ELBOW TO THE TO THEM, UNAUTHORIZED REPRODUCTION OR USE IS P11 PIPE NUMBER _ ;1 s Off- FORBIDDEN. Up QT GPM QUANITY D.T DOMESTIC TEE