Loading...
HomeMy WebLinkAboutPermit File 814 6th Street 11YO G. .* ANACORTES PLANNING & COMMUNITY DEVELOPMENT DEPT. PERMIT CENTER PH (360)293-1901 P.O. BOX 547, ANACORTES, WA 98221-0547 FAX (360)293-1938 v+ • 1891 �.�w� IAN MUNCE, DIRECTOR • EDWIN FRANK, BUILDING OFFICIAL • Email:ed@cityofanacortes.org `9 Catt July 23, 2004 Return Receipt 700 1530 0005 3015 1717 Joel G. Lunz 14482 Lunz Road Anacortes, WA 98221 Ref.: 814 6th Street Dear Joel, It has been almost 18 years since fire damaged this property. Over the years we have had several discussions about completion of repairs of the fire damage. As of this date the repair work has not been completed and the property restored to a usable condition. 1 Several in the community consider the property to be a nuisance. We agree with this assessment. It is now time to complete the repairs or remove the improvements. With this letter you are on notice to provide, within 30 days of the date of this letter, a complete plan and work schedule to complete the project and restore the property to a safe and usable condition suitable for occupancy as required by the zoning and building codes. The project must be completed not later than January 2005. Please be advised that failure to comply with this order could result in assessment of fines and/or penalties prescribed by ordinance. If you have any questions about this order,please contact our office. Respectfully, FOR THE CITY OF ANACORTES Edwin Frank, Building Official Cc: Ian Munce Dean Maxwell Don Measamer Address S/i7 c fj Legal Description z f j /� Ci r> Jiv; rt e f/, Z!,r jjdd! TI! Assessors Account No . z77/ e /G, u.fjUgsa— Permit No . Date Description Date Finaied yes-/ ,z/. /72 cc 6 iz��ti 1��/rr. BUILDING PERMIT CITY OF ANACORTES PERMIT NO.: BLD2001-00161 P.O. BOX 547 APPLIED: 6/1/01 ANACORTES, WA 98221 ISSUED: 6/1/01 (360)293-1901 EXPIRES: 6/1/02 SITE ADDRESS: 814 6TH ASSESSOR'S PARCEL NO.: 3776-009-010-0005 PROJECT DESCRIPTION: Install siding on existing house. Approx 500 square feet OWNER CONTRACTOR JOEL LUNZ 1444 LUNZ ROAD ANACORTES,WA 98221 Primary Phone: Primary Phone: Phone 1: Phone 1: License#: TYPE OF WORK: REP AREA VALUE: $ 500.00 TYPE OF USE: SF LOT: sf REQUIRED SETBACKS: CENSUS CATEGORY: 1ST FLR: sf ZONING: CBD FRONT: ft 2ND FLR: sf Occupancy Groups BASEMENT: sf SIDE 1: ft GAR/CARPORT: sf SIDE 2: ft 1: R3 2: REAR: ft OTHER: s{ 3: 4: REQUIRED PARKING Construction Types -.-4.... ®M A m m A NUMBER OF UNITS: H II 1: SN 2: STORIES: I. NW 11 414 N 0. m® MAC -t '1- II N ti iI M O.I N N 3: 4: BUILDING HEIGHT: w W II ®® II II It C C II g II W 11 W +�"-• 11 r 11rNrWWU6 II FEES N( .01s°- ® H WN W w W J II G9r 1 a a 11 U C a. p Type By Date Receipt Amount • Q'� �W� {I r� PRMT MRD 6/1/01 $10.00 ,-▪ I' AP O"'^"' HIS '— - s II N -VA.. 11 WW A II Y[. C C= 1 11 0. I-. Q V STBC MRD 6/1/01 $4.50 —Id 11 "-Ng"'16"' " 4 W HAS�VrvN ..= 11r�r A I- s lyl 11 11 S W r•• ii .O N O Total: $14.50 — -- :Ins Wz r — ONO GO a• I I W W I I ,Z G H J IIJ L N 11 fJA II NC AO O 1 • II WC ll .-1' s I hereby acknowledge that I have read this permit and state that the above information is correct, and agree to comply 1 with all ordinances and state and federal laws regulating activities co ered by the it. Issued by Appli nt or Owner's Sign-4 CONDITIONS OF APPROVAL: 24 Hour Notice Required For All Inspections 0 , CITY OF ANACORTES BLDG. X PLUMBING 0 MECHANICAL 0 PERMIT • 438$ Telephone 293-5173 ANACORTES, WASH. DATE /" 30 19 PERMISSI9*IS HEREBL GRANTED'TO: OWNER `NA` ®•\ ,?7lr'+^. STREET ADDRESS Sl i.' 4, ST. LOCATION WHERE WORK IS TO BE DONE CONTRACTOR �J ,ems- ! TO ERECT 0 INSTALL X 9R REPAIR � , IN TH F LOWI G MANN R. r;__. ' 1! ;—. Ilf ft0 v>•1 A l " s PERMIT EXPIRES ONE YEAR FROM DATE ISSUED PLANS FOR CONSTRUCTION WEREWERE ❑NOT�. SUBMITTED WORK TO BE DONE BY OWNER,CONTRACTOR 0 RECEIPT OF FEES IS ACKNOWLEDGED AS FOLLOWS: TYPE APPROXIMATE VALUE OF WORK PERMIT FEES ISSUING BUILDING ) 9sc yoga, I tors GAS PIPING PLUMBING AND W.S. - SEWER CONNECTION INSP. MECHANICAL - PLAN CHECK FEE MISC. TOTAL .1 qc'p L tier LEG L DES IPTI L 7 :D ipi te P N Ns- ; Ftaii1/41aw ITv lMebtflno '7 71..rc 7r Qom, City of Anacortes Permit#: BLD-2005-0061 \ 904 6th Street Issue date: P.O.Box 547 ';o ___ —,02 Anacortes, WA 98221-0547 Expire date: 01/31/2006 (360) 293-1901 L'OP • Job Address: 814 6TH ST Permit Type: Single Family Alteration/Repair Permit ANACORTES WA 98221 Project: APN: P56810 Remarks: Remodel existing house with addition of back stairs and kitchen. Office space 1st floor and single family second floor. Owner: GUY DAVIDSON Contractor: Address: 4191 ISLANDER WAY Address: ANACORTES WA 98221 Phone: (206) 384-4459 Phone: License#: General Information: Fees: Building Valuation 65000 Plan Review Fee 213.20 # Forced Air Furnace<=1,000 2 State Building Code Fee 4.50 #of Bathtubs 1 Mechanical Permit Fees 90.25 #of Clothes Washers 1 Plumbing Permit Fee 90.00 #of Dishwashers 1 Building Permit Fee 328.00 #of Gas Piping 1 Traffic Impact Fee 655.20 #of Gas Water Heaters 1 Total Calculated: 1,381.15 #of Hose Bibbs 1 Deposits/Receipts: 0.00 #of Water Closets 2 #of Lavatories 3 Total Due: 1,381.15 #of Kitchen Sinks 1 #of Ventilation Fans 3 nn rD 'n 1 ni rt• 0 O t ra N) m r: a ar r THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF., rj CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. q; 9 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN Og.rj a NOT, THE GRAN ING OF A P R DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LO G CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. tic „ SIGNAT F OWN R ALIT RIZE GENT TOED BY PROPERTY ID NO. P61124 ASSESSOR'S TAX ACCOUNT NO. 3855-000-018-0000 LEGAL DESCRIPTION: LOT 10, BLOCK 9, AND LOT 13, BLOCK 6, BOWMAN'S CENTRAL SHIP HARBOR WATER FRONT PLAT OF ANACORTES, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 2 OF PLATS, PAGE 33, RECORDS OF SKAGIT COUNTY, WASHINGTON. EXCEPT THAT PORTION OF LOT 13 LYING EAST OF A LINE THAT IS 88 FEET EAST OF AND PARALLEL WITH THE EAST LINE OF AVENUE "Q", BLOCK 6, SAID PLAT. (DEED A.F.NO. 8904100036, RECORDS OF SKAGIT COUNTY, WASHINGTON) ZO\iNG: CENTRAL BUSINESS DISTRICT REQUIRED SETBACKS: FRONT YARD 0 FT. REAR YARD 0 FT. SIDE YARD 0 FT. SIDE YARD 0 FT. HEiGF-IT LIMIT 35 FT. ALLOWABLE LOT COVERAGE: 100% ACTUAL LOT COVERAGE: 38.8% MAIN FLOOR 998 SF UPPER FLOOR 998 SF PORCHES 240 SF LOT COVERAGE 1,238 SF PARKING: I (HC VAN ACCESS) 2 STANDARD SPACES 311 NSF OFFICE SPACE = 1.5 SPACES G '° ' 2 BR UNIT = 1.6 SPACES C JtO\ e 10.:S U al,* c„,,L 8B 161 ALLEY ) 31.94 FT : & S m O z /l/l1 I 0_ i_r 7 0 in .4 Lt. Qr Q FENCED YARD FOR TENAN"5 LL it W �,tri al to0-1 o a cp 0- w / I � N }- j/ HOUSE 2.2' }- I FROM LINE U W Q n Q O▪ IL N,11frirr- O Q OUSE 1.4' z4 a H FROM LINE J D .i-_ a... -, r r M w I . Z I ''1i II ;, 814 6th ST. JAN 10 E i 1 V N Li boo ULi FENCE Iro r ON LINE CONCRETE CITY SIDEWALK 6T1-1 STREET SCALE: I" = 151 DAVIDSON 814 Sth STREET ".` RICHARDSON Architecture 4 Flaming.Arcmnee,WA 34440-239-9WB1 n n City of Anacortes Summary of Applicable Fees Due Prior to � I rq� Building Permit Issuance (Excluding Building Permit Fees). � Name of Applicant/Project: C� b .� Strom Site Location: �1\-\ 0 C2- Date of Application: 1 Place a Check Mark Below Next to Item that is Applicable • Yb vre v�e.o-s_ un- 3za) nt A Sanitary Sewer GFC S Storm Water GFCPI VI, V.sartstty.\ S Engineering Plan Review/Public Works \ S VV� tip Impact Fees/Road S ( 5cS y\i k Impact Fees/Fire S y* Impact Fees/Parks S Total Fees&Charges Due S Comments &Conditions: f - STM DRAINAGE UTILITY l iAERC_ _ L RATE BILLING CALCULA L. 2 - ORDINANCE NO. 2419 - ENGINEERING/PUBLIC WORKS DEPARTMENT: `, DATE: I- � EYm- BY: ' 6 ADD A NEW COMMERCIAL ACCOUNT CHANGE AN EXISTING ACCOUNT COMMERCIAL STORM DRAIN UPLAND DELETE AN EXISTING ACCOUNT COMMERCIAL SALTWATER DISCHARGE OWNER'S NAME C.70 V ay. S On SERVICE ADDRESS v‘Lk SINGLE PARCEL BILLING MULTIPLE PARCEL BILLING COMPLETE A SEPARATE FORM FOR EACH PARCEL TO BE BILLED. IF MORE THAN ONE PARCEL IS COMBINED ON ONE BILL,STAPLE SHEETS TOGETHER. t • x'+ s .S 6r -2i1 %;. .>;;rt N g Re nt/ ammo nsaMyYMd .' i r � u�tlk' t8 O *:T -, • MASTERye - 3is PLEASE NOTE ANY UNUSUAL BILLING INFORMATION(E.G., PARCEL USES PRIVATE RETENTION FACILITIES, DIRECT SALT-WATER DISCHARGE, ETC.): City of Anacortes Building Department Memo To: Ian Munce, Planning Director From:Don Measamer, Senior Plans Examiner SM- ---N CC: Date: 1/28/2005 Re: Traffic Impact Fee—814 6th Street— Partial Change of Use Mr. Guy Davidson is proposing a renovation of the existing single-family residence at 814 6th street, which would include office space on the first floor and a single family dwelling on the second floor. It appears the change of use from single family residence to office space, 728 SF, on the first floor would require a traffic impact fee per Ord. No. 2277. Please review the following traffic impact fee calculation and let me know if you concur by signing below. Thank You (728-1000) 0.728 x$900.00 = $655.20 1/3/JOS Ian Munce, Planning Director Date II 1 .41), lllhll200412200186ll��ll IIII JI IIi lU Skagit County Auditor 12/20/2004 Page 1 of 3 4:00PM LIMITED EASEMENT Grantor, City of Anacortcs, a Washington Municipal Corporation. for no consideration. hereby grants, conveys and quit claims to Grantee, Guy Davidson, as his separate estate, a limited easement for ingress and egress. landscaping, and construction and maintenance of a ramp for handicapped access over and across the following described property, situate in Skagit County, Washington: The Easterly eight feet of the following described property: Lot 12, and that portion of Lot 13, lying Westerly of a line that is 88 feet East of and parallel with the East line of Avenue Q, Block 6, Map of the City of Anacortes. according to the plat thereof recorded in Volume 2 of Plats, pages 4 through 7, records of Skagit County, Washington. P54943 Grantee agrees to landscape and maintain the easement area in an attractive manner. This easement is for the benefit of and appurtenant to the property shown on Exhibit A owned by Davidson. (P56810 and P549441 Dated this 'day of December. 2004. Grantor: ,rantee: SKAGIT CgUNT1 WASHINGTO Real &state excise Tax CITY OF ANACORTES l�2ci/ DEC 2 p 2004 -- c «-w H. Dean Maxwel , Mayor Skagit amGounty ount FT'td rea sure ,uy Davidson s Deputy By: EXIIIBIT A Parcel A. Lot If). Block 9, BOWMAN'S CENTRAL SHIP HARBOR WATERFRONT PLAT OF ANACORTES, according to the plat thereof recorded in Volume 2 of plats, page 3 records of Skagit County. Washington. Parcel B: All that portion of Lot 13 lying East of a line that is 88 feet East of and parallel with the East line of Avenue Q, Block 6, MAP OF THE CITY OF ANACOR'fES, according to the plat thereof recorded in Volume 2 of Plats, pages 4 through 7, records of Skagit County, Washington. All situate in Skagit County, Washington. 11Z�111111�1111111h Ih12 ohoH�INa111611 Skagit County Auditor 12/20/2004 Pane 2 of 3 4°OOPM ACKNOWLEDGMENT STATE OF WASHINGTON COUNTY OF SKAGIT ) ss. On this ` hday of December 2004 before me, personally appeared H. Dean Maxwell, to me known to be the Mayor of the corporation that executed the within and foregoing instrument, and acknowledged the said instrument to be the free and voluntary act and deed of said corporation for the uses and purposes therein mentioned, and on oath stated that he/she/they is/are authorized to execute said instrument. Given under my hand and official seal this'* day of December 2004. pa YATF;‘‘ttt Cc t fi S -k L A 41- .•co14 E,yp•.• It Notary Public in and for e State of Washington f V;'�, ,�ARy Rc`:, tip Residing at:--�Y`0,,epi\J J i 0 ° pUe\ �0 My commission expires: \,-=,?lr1/(1`i tt 12,9,••' �J ttt��q o`W • ThNINilll III I I IIININNINIIII IIIIIIIIIIII 200 12200186 Skagit County Auditor A')Y)fl I')flflA Dann '1 of ') A•nnDNA • si-io" ALLEY I31,94 FT 1 - - - - - - - - I 1 r I I 4 1 t 1 � I I d i _ W Iz O I nb I H 111 '3 COW. W � 1 i0- 0 ,r4 I 0 0 1 a< O Ia C I T 0 , I GRASS 1 LOT 0 i 1 \ / . iO'kTC' 16 SHRUBS BESIDE CITY PARKING LOT: ,A1/ i r- 2 PIERIS JAPONICA . �n ' CO 3 HYDRANGEA 0 I ! Q7 4 HEATHER t/ 101 2 GOLDEN YEW 4, , f' lG r I LAVENDER 0 ' s 3 PERNETTYA MUCRONATA I VICTORIA CEANOTHUS !j — THESE MEDIUM SIZE SHRUBS ARE 0 SELECTED TO PROVIDE A VARIETY sI/, OF TEXTURES, SOME EVERGREEN, a SOME DECIDUOUS, SOME FLOWERING 0 �;O I A ROW OF LARGE ROCKS ALONG I THE EDGE OF THE PLANTING AREA I WILL PROTECT THE SHRUBS FROM 0 Q- ERRANT VEHICLES s/ 'E I I 0 W. 9 HOUSE 1.4' ` s LU ZI FROM INE 1iii O , ` l i 0 1 I ' I > * - - 1 1 I +ice II/L` i� �'`�' v.t -' I c+1 GRASS 4 GRASS -' / �r ;.; 1 W o _ + CONCRETE CITY SIDEWALK jYFffO1Fflflh1rFn - JUL 1 2 2005 814 6774 5TREET Ji_ V!_`3L1 U LPL LANDSCAPING FLAN SCALE: 1/8" = 1 -O" _ si-lo" ALLEY I 31.94 FT I I - - - - - - -� - - I I I f- I 4 I 0_ cn d i W !L I ►Q z O IHi m 0 0:0 el6. I W w rm m CDI L O O � 00 CITY = dQ I GRASS o ,I Dfi PARKING * ' ) ` , L LOT f D \ / I I 0 f I/ _ w �. : I— IL 16 SHRUBS BESIDE CITY PARKING LOT: <: 1G,r I , I 2 PIERIS JAPONICA ,I , i i ' 00 3 HYDRANGEA D' I I Q7 4 HEATHER i 6l Y4l�, 2 GOLDEN YEW iff;A . Y/,� I LAVENDER f o% i 3 PERNETTYA MUCRONATA 0 i 1 VICTORIA CEANOTHUS 'Ali 1 f, I THESE MEDIUM SIZE SHRUBS ARE O I SELECTED TO PROVIDE A VARIETY OF TEXTURES, SOME EVERGREEN, r-+. , SOME DECIDUOUS, SOME FLOWERING slot 1 A ROW OF LARGE ROCKS ALONG „rf*y THE EDGE OF THE PLANTING AREA D WILL PROTECT THE SHRUBS FROM 4 ; � \ . ERRANT VEHICLES *+t* I s- 4 f ^; e 1 / I I O//� a I ;,- 111 Z i HOUSE 1.4' FROM INE D 4 i II 0 11 • 4A/f, V Rat 0 1 / I ‘ i \ I I I III‘• #x ..I m I 0 At/ GRASS GRASS 1 1 • , 1 W 'i D.f _ 31.9�o FT—d3- - - - i _ � r 1 CONCRETE CITY SIDEWALK 71, Trill1111fill JUL 1 2 zoos 814 6774 5TREET --................ LANDSCAPINCH FLAN SCALE: 1/S" = 1'-O" G1` U» y.,,. City of Anacortes Permit#: BLD-2004-0200 904 6th Street Issue date: 11/19/2004 P.O.Box 547 C Anacortes, WA 98221-0547 Expire date: 01/18/2005 '' ' (360) 293-1901 Job Address: 814 6TH ST Permit Type: Demolition Permit ANACORTES WA 98221 Project: APN: P56810 Remarks: Initial demo for interior and exterior remodel Owner: GUY DAVIDSON Contractor: BELL Si SONS CONSTRUCTION Address: Address: 2025 FOWLER PL MT VERNON WA 98273 Phone: Phone: License#: BELLSC*025R2 General Information: Fees: Total Calculated: Adjustments: Deposits/Receipts: Total Due: I THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE G NTING OF A % RMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR CAL LA A/,' -TING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. 01/4. 01 SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY u+;wit,- bag,:3a41t40-17.?- '+F s'i.Y4'c '71'9...7'¢+n4rt44:-,--574.4'aRffi,4'4"q: ' 'it 4.17• :4 4,14 ir414""*VV^"'y "4•;4t. :`. ...;'^Kge.. ... CITY OF ANa� a it s cfraCOMM ifl7PrDEV.ELOPMEN!.DE pTMENT PutrAnvc 904.swill P f7 Ye ra 4, �� CEO r �Of . . :' •, ':ANICY This is to cerdfy''th'at the oitupands. r ' • has been Inspected and is hereby approved for use. • 814 6th Street BLD.-2005-0061 Address of Building/Premises Building Permit No. Occupant Suite No. Business Registration No. Guy navidaon Vitt B—R3 Type yin of Construction Type of Occupancy 4191 Islander Way — Anacortes, WA 98221 CEA Address of Owner Zoning District Maximum Occupancy Load 2 226 squares fset- Soonest-fret Statement of Restrictions Inspection Appdval: Issued By: ' Fre ahel Fat Ogn :41. r gate Date THIS' '�. � ���, " b�a A�"��;,5. '.=v„ Rewaed 5 89 To t. _ v p Pi ;f� i 1{i ai t$ e 1 •t, Site Address: VVL/ • 6 Lot: Block: Addition: Permit No. Date Description of Permit 21386 00's a PertivE q/a7/ o /4- lb Toe/ Linz Vai/90 //i Pra„, Tod 4,417 0/l9a Phone. 6//71 S , r lzs .s/a'e /�en*-i- gle-1/Rcl 1 %c% Toed .11/4 2 y%� �y €e!`l/i6 /t4-- lc roe, ram .5/Il/91/ mci icevn z 1/1.3/oc, Tinpror csz d 2sriyd zi/moles eCri qq- or21. '7/3/%16 avrvebiedeC rm/t1 111460 frOltwidcrAy r iOn d r y - l 31460 kirk 36Pd 1 z V'asVe-o t Tad Lech z /e of) /0/0 6/13/ & c ,`f(na L a ' h-` +l'>tlr eo. OI. - '� 3 in) JL4 a/pp//Ced/'on • i Site Address: Lot: Block: Addition: Permit No. Date Description of Permit 7/5/60 ar 40", 3 e/ /Canh of eern,114/1‘ 8/1660 Tit' Lona ta3/O/ Asir- % Leif 4 z 61-os , 1 le / e ;Id 'e1777i`tL 1, _- FT << e dl nc<tiu fv ` / ' ' '/ 8x20 PARKING t� - z - .11 T• - OPE TO ALLEY ?( / , k i A'' Q; � '' ''/// Z lil 0 ' Z U fit ,, ts- 1,— „ / 2/, , 03- i \-• -in , I IH- Wt Vte:tHac r, n4 . :4 A, I Q lJ FENCED YARD FOR TENANTS I (fir, I a ` uW e""G� 4 L� at ft 1 1 4 LI A U m , \ Q V L FROM LINE \ to I I I , AID �la I / 1 I HOUSE 1.4' 0 i FROM LINE _ 814 6th ST. � �e0.� 1 17 .rre \ ,7 >k 7 FENCE ;�— ON LINE Aill �I 1I L _ }1-soFT--e- - - - \ CONCRETE CITY SIDEWALK ,„ 0 I 4 =,i y"' :�'.:r s 7,"su y rsJ � 4 4 i , trt< ,,y/.4 r i SITE FLAN Y , ,., SCALE: 1/8" = 1'-O° n^ . `b1 On spic»-icv-ek).) Anacortes Planning & Community Development Dept. Permit Center ~to P.O.Box 547,Anacortes,WA 98221-0547 PH(360)293-1901 'coal Ian Munce,Director • Edwin Frank,Building Official FAX(360)293-1938 May 13, 2005 Post-it®Fax Note 7671 Date c//6 cc- pag s� Co� ISIFS �2,z_ R' Phone# X-Fire :7620 "71 S' i. , 1511 Kentucky Street Bellingham, WA 98229 RE: 6202 Washington Court 13d Fire Sprinkler The following are comments and questions regarding the plan review done on the above- mentioned project. Please revise drawings as needed. 1. Provide sprinkler heads in all rooms that do not meet the criteria specified in NFPA 13d Section 8.6.3. Such as lower floor—bathrooms, wine room, mechanical room and Main Floor—mud room, powder room and hallway at mudroom. Lastly, Upper Floor—bath at bedroom 2, and closet bedroom 2. 2. Smoke detectors shall be provided in accordance with NFPA72-NFPA 13d Section 6.3-(2). 3. Indicate required sign per NFPA13d Section 6.3 —(5) minimum '/4 inch letters. 4. Provide verification of available flow/pressure at the street, taking into consideration the water meter. Verify proposed water meter size need to provide flow. Thank You, CITY OF ANACORTES Don Measamer Senior Plans Examiner DM:md Anacortes Planning & Community Development Dept. G 1KY 7 "-` Permit Center ',Oar/ P.O.Box 547,Anacortes,WA 98221-0547 PH(360)293-1901 "Ions K Ian Munce,Director • Edwin Frank,Building Official FAX(360)293-1938 April 14, 2005 Rod Durham X-Fire Detection & Suppression 1511 Kentucky Street Bellingham, WA 98229 RE: Group R Occupancy 13 D Fire Sprinkler System 814 6th Street Anacortes, Washington 4 Dear Mr. Durham, The following comments are based on the drawings and application provided for the fire sprinkler system at 814 6th Street. The Anacortes Assistant Fire Chief and myself completed the review. 1. The 2003 International Building Code, and the 2003 International Fire Code require fire protection for the entire building. Please provide information showing how the building complies with the 2003 IFC, Section 903.2.7. Sprinkler system provided throughout all buildings with a Group R fire area. The Fire Department has determined that IFC Section 903.2.7 requires a sprinkler system throughout the entire building. 2. The site plan needs to show water meter size and locations. 3. Please provide manufacturers installation guidelines and listing for the Raupex Tubing. Please provide a code analysis, which describes proposed compliance with 2003 IFC and IBC. If you have any questions, please feel free to contact me at 293-1901. Sincerely, CITY OF ANACORTES Don Measamer Senior Plans Examiner DM:md 1/ CITY OF DO NOT REMOVE sail- CORRECTIONS REPORT ❑ Building codes 293-1901 ANACORTES ❑ Fire codes 293-1925 ❑ Public Works 293-1920 The corrections listed below are hereby ordered and must be completed within days. " OWNER/CONTRACTOR I PERMIT NUMBER ADDRESS NIS \ \ U ` I DATE ❑ NETT APPROVED FOR COVER ❑ NOT APPROVED FOR OCCUPANCY OR USE ❑ CORRECTIONS NEEDED WSTOP WORK --- - .... ' (..). CsP iC C3 , o,,,, -tl.sj\ 5 ,`) .,-• r - ` ..„ .,-w, 1A- 4Ic "Li a c, _`alc—r1 . .,,- '- L, c` .a ` ,--1l".7-4 , ';_i_i, -' St:— �. > `--``— , • J S..)Cv.2., << ,-¢ I t e ? �..an i- ,.__7 NOTIFY INSPECTION OFFICE WHEN READY FOR REINSPECTION INSPECTOR t .. : ,_ City a�f;Anaeortes . . .:.. .. : .. ..:: . .'. . >~ ; .,Building:P.erlinXt'Application_... .. . . . Site Address: c{/4y 6: 0 fC Parcel No.: Lot: Block: Div: Addition: OWNER LENDER. CONTRACTOR Name Name Name 19y,L'.bx� bees-I y.zel Mailing Address Mailing Address Mailing Address City: State: Zip: City: State: Zip: City: State: Zip: Contractor Lic.No.: Phone No.: l /� Phone No.: Phone No.: Exp Date: Contact Person: ROAD b J kv Lt t}.t,t, Phone No.: .36 v— GCS " `d 4'd'✓y OCCUPANT USE (Check One) Single Family: Multi-Family: Apartment:_ Condominimum: Senior Housing:_ Retail: Office: Restaurant: Manufacturing:_Storage: Bank:_Assembly: Accessory: Automotive Repair: Other(Specify) DESCRIPTION OF WORK: Co L44,6 -1,-.. .L,.-- R ci Five 9/9r 4, A/4, GENERAL INFORMATION Street Setback: ft. 2"d Floor: sf. (Circle YorN) 1a Side Setback: ft. 3`d Floor: sf Shoreline/Wetlands Y N 2"d Side Setback: ft. Basement: sf. Water on/Adj.To Property Y N Rear Setback: ft. Occ.Group: Soils Report Y N Use Zone: Carport Area: sf. Sensitive,Area Y N Type of Construction: Garage Area: sf. Latecomers Agreement Y N Lot Area: sf. No.of Stories: Fire Hydrant(250 Feet) Y N No.of Dwellings: Building Height: Variance Y N Lot Coverage: Deck Area: sf. Covenant Y N ls`Floor sf. Flood Zone X A AE VE Project Valuation(Labor and Material Cost): il' S 1(0`'. d' THIS APPLICATION IS RECEIVED BY THE BUILDING OFFICIAL UNDER THE PROVISIONS OF THE UNIFORM BUILDING CODE,AND SHALL EXPIRE BY LIMITATION AND BECOME NULL AND VOID IF PERMIT IS NOT OBTAINED WITHIN 180 DAYS OF THIS APPLICATION. BY AFFIXING MY SIGNATURE I HEREBY CERTIFY THAT I AM THE LEGAL OWNER OF THE PROPERTY FOR WHICH THIS APPLICATION IS ISSUED OR AN AUTHORIZED AGENT OF THE OWNER. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT,INCLUDING CALLS FOR INSPECTIONS. SIGNATURE: c �� DATE: 914/U6-- . •• 'PRIO-ViDE13 BY 1-A..114 itIEGISTSPS . CONST CONT t:GENRA ; REGiST • # :lol15/2006 debt XFIRE**96126 0/1512004r EFFECTIVS. Dt.rt 1 1511 KENTHCKY ST BELLINGHAM VA ,9S229 sitiature , Issued by DEYARTM.EflipP,ILAyOR AN_ D - F I RE /r,' �, �rti; 0 / ,ono. �):ih• DETECTION & SUPPRESSION 1511 Kentucky Street Bellingham, WA 98229 "`w•1 360-715-8088 FAX 360-756-6946 X-FIRE.BIZ LICENSE: XFIRE**961PN Department of Jurisdiction: Skagit County Submitted to: DANtA1N— Date: 4-7-2005 (Ary •Qb . 3GO_ 7 , r-55,s>) Job Name: Darrin Bell/Davidson Job Address: 814 6 th Street MT. VERNON,WA Sprinkler type: 13d Date file # 1020 ��\\caC_ t_t_y.,' 4—d'—Ot Koh i r t t rkj• HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.4 - SUBMITTAL. ENGINEERS : X-FIRE. (360) -647-3318 LICENSE DESIGNER : TERRY GOETZ DATE : 04-08-2005 FILE : DAVIDSON JOB NAME : Davidson Partial LOCATION : 814 6TH STREET ANACORTES WA DESIGN DATA. DESIGN CRITERION: NFPA 13D MIN SPR FLOW : 14 Gpm AREA PER SPRINKLER : 256 Sq Ft TOTAL rAT CULATED AREA : 256 Sq Ft TOTAL SPRINKLERS CALCULATED : 1 Heads FLOW DATA. TOTAL SPRINKLER FLOW : 14.0 Gpm DOMESTIC DEMAND : 5.0 Gpm TOTAL WATER REQUIRED : 19.0 Gpm BASE OF RISER NODE: FLOW: .0 Gpm PRESSURE: .0 Psi XFIRt. FS° aeeerlmeare 967.A z`'-F - 'c le ` Terrell L. Goetz > Al"'19A / IR o are' ` AUTHORITY HAVING JURISDICTION : SKAGIT COUNTY O4 �pe 9h Dec° PHONE HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.4 - SUBMITTAL. Page 1 ENGINEERS : X-FIRE. (360) -647-3318 ADDRESS : 1501 Kentucky Street, Bellingham WA 98229. Date: 04-08-2005 File: C:\RESDEN44\DAVIDSON.RES JOB : Davidson Partial SOURCE I STATIC : 55.0 Psi RESIDUAL : 45.0 Psi FLOW : 28 Gpm DESIGN I SPRINKLER MANUF : Viking MODEL : VK436 I SPRINKLER Q 14.0 Gpm VALVE .0 Psi SPRINKLER P 7.2 Psi METER .0 Psi NODE ELEVATION K- PRESSURE DISCHARGE NO. Feet FACTOR Psi Gpm 1 25.0 5.2 7.3 14.0 2 25.0 9.1 3 25.0 8.1 4 25.0 9.3 5 25.0 9.9 6 25.0 9.4 7 25.0 8.9 8 25.0 10.5 9 25.0 10.9 10 6.0 17.7 5.0 DOME 11 6.0 SOURCE 32.3 19.0 , SPRINKLERS FLOWING 1 AREA PER SPRINKLER 256 Sq Ft TOTAL DESIGN AREA 256 Sq Ft XFIRF,. MIN SPRINKLER FLOW 14 Gpm -4? ,y,,` =e,,,,,care'9s,Ay REQUIRED DENSITY .055 Gpm/Sq Ft ''q COMPUTED DENSITY .055 Gpm/Sq Ft N /A Terrell L. Goetz i TOTAL SPRINKLER FLOW 14.0 Gpm 3 c�ry<`L,�a giC �- - TOTAL DOMESTIC FLOW 5 Gpm /� '�"�L`��" �� TOTAL WATER REQUIRED 19.0 Gpm a°.,` yi-�""'� P aka �n,,,spnr,0 ` o c TOTAL SPRINKLER PRESS 32.3 Psi rh`O°�n oe=="�� WATER METER LOSS, .0 Psi VALVE FIXED LOSS .0 Psi Copyright(2004) SUPPLY PRESS AVAILABLE 50.1 Psi by DEMAND PRESS REQUIRED 32.3 Psi Hydronics Engineering PRESSURE CUSHION 17.8 Psi 34119 Fremont B1, Suite 609 Fremont, Ca. , 94555 MAXIMUM VELOCITY 10.3 F/S (800) 845-9819 HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.4 - SUBMITTAL. Page 2 ENGINEERS : X-FIRE. (360) -647-3318 ADDRESS : 1501 Kentucky Street, Bellingham WA 98229. Date: 04-08-2005 File: C:\RESDEN44\DAVIDSON.RES JOB : Davidson Partial PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 1 q= 14.0 K= 5.2 L= 8.0 Pt 7.3 Pt 7.3 1 Q= 8.8 F= RR F= 2.0 C= 150 Pe .0 Pv -.4 Vel= 7.9 D= .675 TL= 10.0 .1613 Pf 1.6 Pn 6.8 7 Pt 8.9 2 q= .0 K= .0 L= 13.0 Pt 9.1 Pt 9.1 2 Q= 2.2 F= RR F= 2.0 C= 150 Pe .0 Pv .0 Vel= 1.9 D= .675 TL= 15.0 .0121 Pf .2 Pn 9.0 7 Pt 8.9 1 q= 14.0 K= 5.2 L= 12.0 Pt 7.3 Pt 7.3 3 Q= 5.2 F= RR F= 2.0 C= 150 Pe .0 Pv -.1 Vel= 4.7 D= .675 TL= 14.0 .0615 Pf .9 Pn 7.1 3 Pt 8.1 5 q= .0 K= .0 L= 32.0 Pt 9.9 Pt 9.9 4 Q= 6.6 F= RR F= 4.0 C= 150 Pe .0 Pv - .1 Vel= 3.6 D= .87 TL= 36.0 .0278 Pf 1.0 Pn 9.8 7 Pt 8.9 2 q= .0 K= .0 L= 13.0 Pt 9.1 Pt 9.1 5 Q= 2.2 F= RR F= 2.0 C= 150 Pe .0 Pv .0 Vel= 1.9 D= .675 TL= 15.0 .0121 Pf .2 Pn 9.0 4 Pt 9.3 3 q= .0 K= .0 L= 33 .0 Pt 8.1 Pt 8.1 6 Q= 5.2 F= RER F= 5.0 C= 150 Pe .0 Pv -.1 Vel= 4.7 D= .675 TL= 38.0 .0615 Pf 2.3 Pn 8.0 8 Pt 10.5 4 q= .0 K= .0 L= 11.0 Pt 9.3 Pt 9.3 7 Q= 2.2 F= RR F= 2.0 C= 150 Pe .0 Pv .0 Vel= 1.9 D= .675 TL= 13 .0 .0121 Pf .2 Pn 9.2 6 Pt 9.4 6 q= .0 K= .0 L= 1.0 Pt 9.4 Pt 9.4 8 Q= 2.2 F= RR F= 2.0 C= 150 Pe 8.2 Pv .0 Vel= 1.9 D= .675 TL= 3.0 .0121 Pf .0 Pn 9.4 10 Pt 17.7 I 9 q= .0 K= .0 L= 5.0 Pt 10.9 Pt 10.9 9 Q= 7.2 F= RB F= 8.0 C= 150 Pe -8.2 Pv -.3 Vel= 6.4 D= .675 TL= 13 .0 .1104 Pf 1.4 Pn 10.6 10 Pt 17.7 XFlRE._ I 42 ..e ^«eertif,c.,fn set Sa p,-C 1. I .", 2 14h Terrell L. Goetz ,3 gp4-1f111.7 1 iLJ MMI, Al c % , ^nf,: J� di < yJ 4q tnetron SPrtn " 9 �\ 4loe9h Dece,Pc HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.4 - SUBMITTAL. Page 3 ENGINEERS : X-FIRE. (360) -647-3318 ADDRESS : 1501 Kentucky Street, Bellingham WA 98229. Date: 04-08-2005 File: C:\RESDEN44\DAVIDSON.RES JOB : Davidson Partial PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE NO. Gpm FITTING TYPE FTG FR- LOSS Psi END DIAMETER TOTAL (Psi/Ft) 5 q= .0 K= .0 L= 10.0 Pt 9.9 Pt 9.9 10 Q= 6.6 F= RB F= 11.0 C= 150 Pe .0 Pv -.11 Vel= 3 .6 D= .87 TL= 21.0 .0278 Pf .6 Pn 9.8 ' 8 Pt 10.5 8 q= .0 K= .0 L= 1.0 Pt 10.5 Pt 10.5 11 Q= 11.9 F= RR F= 4.0 C= 150 Pe .0 Pv -.3 Vel= 6.4 D= .87 TL= 5.0 .0814 Pf .4 Pn 10.2 9 Pt 10.9 9 q= .0 K= .0 L= 12.0 Pt 10.9 Pt 10.9 12 Q= 19.0 F= RGS F= 55.0 C= 150 Pe 8.2 Pv -.7 Vel= 10.3 D= .87 TL= 67.0 .1952 Pf 13.1 Pn 10.2 11 Pt 32.3 Meter = .0 Q= 19.0 cc< SOURCE >>> Pt 32.3 E=>45-Elb L=>90-Elb B=>TeeBch R=>TeeRun C=>CouPlg S=>SwgChk G=>GatV1v xn RF-. eao ,e eernncn, see '� o''' Level 're Z °a d► ' Terrell L4 . Goetz - i/ 3 ,104-10-1111 4. �,ajhr r"n Sp,in c.,, oogh Oeccp HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.2 - SUBMITTAL. ENGINEERS : X-FIRE. (360) -647-3318 ADDRESS : 1501 Kentucky Street, Bellingham WA 98229. DATE : 04-08-2005 FILE : C:\RESDEN44\DAVIDSON.RES JOB : Davidson Partial i PSI FIRE SPRINKLER HYDRAULIC GRAPH 100 90 80 70 60 50�� 40 V 10 15 20 25 30 35 40 45 50 FLOW - Gpm 0- 0 Supply Curve • Demand Curve Static : 55.0 Avl Pr : 50.1 @ 19 Resid : 45.0 Reg Pr : 32.3 @ 19 Flow : 28.0 Pr Cush : 17.8 C XFIRe., F� (e eertnicaee�'90, 4 S.13 ` level 4 •` I C L ` ns'e ( J ,y' Terrell 1. Goetz 3 '1 OQ„'i G- 9'1 7 ad o,ecfr w'S.e-,' 7 an Spro ¢( rh,O"9h DececMv Copyright: Hydronics Engineering, 2004. 34119 Fremont Bl, Suite 609, Fremont, CA. 94555. (800) 845-9819. March 12,2004 Sprinkler 140j RESIDENTIAL NIKING® TECHNICAL DATA S N VKD4036'(5 2PK-I ACTOR) Testing: U.S.A. Patent No.4,831,870 5. INSTALLATION Thread Size:"A"(15 mm)NPT Nominal K-Factor:5.2 U.S.(7,5 metric*) WARNING: Viking residential sprin- ° +•" — *Metric K-Factor shown Is for use when pressure is klers are to be installed in accor- measured in kPa.When pressure is measured in dance with the latest Viking technical BAR,multiply the metric K-Factor shown by 10.0. data,the latest edition of applicable 1,( f°-----_; ; Overall Length:2-1/4"(57 mm) standards of the National Fire Pro- \1! . d dI _ _ SPRINKLER MATERIALS Frame:Brass Castings UNS-C84400 similar Authorities Having Jurisdic- I` Deflector:Brass UNS-051000 tection Association and any other tion,and also with provisions of goy- ' • ^i11 Bulb:Glass,nominal 3 mm diameter ernmental codes, ordinances, and Belleville Spring Sealing Assembly: standards whenever applicable. Nickel Alloy, coated on both sides Final approval and acceptance of — "a- with Teflon Tape all residential sprinkler installa- Compression Screw:Brass UNS-C36000 tions must be obtained from the 1. PRODUCT NAME Pip Cap and Insert Assembly: Copper Authorities Having Jurisdiction. Viking FreedomTM Residential Pendent UNS-C11000 and Stainless Steel Sprinkler SIN VK436t UNS-S30400 When using Viking Residential Sprinkler 4.ACCESSORIES SIN VK436 for systems designed to • Sprinkler Base Part Number 12166 NFPA 13D or NFPA 13R, apply the Sprinkler Cabinets: listed areas of coverage and minimum • Available since 2003 A.Six-head capacity: Part No. 01724A tThe Sprinkler Identification Number (SIN) is B. Twelve-head capacity: Part No. water supply requirements shown in the stamped on the sprinkler deflector. 01725A approval chart on page 140 k. 2.MANUFACTURER Available since 1971. For systems designed to NFPA 1 The The Viking Corporation Sprinkler Wrenches: number of design sprinklers is to be the 210 N.Industrial Park Road A. Standard wrench: Part Number four most hydraulically demanding Hastings, Michigan 49058, USA 10896W/B(available since 2000) sprinklers. The minimum required dis- Telephone: (269)945-9501 B. Wrench for coated and recessed charge from each of the four sprinklers Fax: (877)384-5464 384-5464 sprinklers: Part Number 07398W** is to be the greater of the following: (available since 1990) or Part No. • The flow rates given in the approval e-mail:techsvcs@vikingcorp.com 12144W/B**, available since 2003. chart on data page 140 k for NFPA 3.TECHNICAL DATA NOTE: Recessed pendent sprin- 13D and NFPA13R applications for Glass-bulb fluid temperature rated to klers with protective caps must each listed maximum area of cover- -65°F(-55°C). use wrench 12144W/B. age,or —kW ratchet is required(not available from Vr Rated to 175 psi(1 207 kPa)waterwork- • A minimum discharge of 0.1 gpm/sq. king)' ft.over the"desi n area"consistingof ing pressure. 9 Refer to the "Sprinkler Accessories" Factorytested hydrostatically to 500 psi the four most hydraulically demanding (3 448 kPa). section of the Viking Engineering and sprinklers forr the coverage areas be- Spring:U.S.A.Patent No.4,167,974 Design Data book for information on ing protected by the four sprinklers. Bulb: U.S.A. Patent No.4,796,710 sprinkler accessories. NOTE:The A8=SxL method must be Sprinkler Nominal Sprinkler used to determine the sprinkler pro- Maximum Ambient Bulb tectionarea of coverage per NFPA 13. Temperature Temperature Ratings Ceiling Temperature' Color Classification (Fusing Point) Refer to the "Viking Residential Ordinary 155°F(68°C) 100°F(38°C) Red Sprinkler Installation Guide" pages Intermediate 175°F(79°C) 150°F(65°C) Yellow (i-iv) for general care, installation, Sprinkler Finishes:Brass,Chrome-Enloy®(patents pending),White,and Black and maintenance information. Footnotes 1 Based on NFPA-13.Other limits mayapply,dependingon fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation stan- dards. 2 The sprinkler temperature rating is stamped on the deflector. Table 1 Note: Units of measure in parentheses Replaces page 140 j-m,dated June 13,2003.Refer to residential sprinkler technical may be approximations. data page(i-iv)for general care,installation,and maintenance information. Form No. F 081202 Sprinkler 140 k March 12,2004 FREEDOM' RESIDENTIAL VIKING® TECHNICAL DATA SINPENDNT VK436 (5.2 SPRINKLER K-FACTOR) Deflector Style NPT Thread Size Nominal K-Factor Overall Length Sprinkler Base Part Sprinkler Identification Inches mm U.S. metric? Inches mm Number2 Number(SIN) Pendent 14 15 5.2 7,5 2-1/4 57 12166 VK436 Approval Chart Temperature KEY ' i— Finish Residential Pendent Sprinkler SIN VK436(5.2 K-Factor) MX4—Escutcheon(if applicable) For systems designed to NFPA 13D or NFPA 13R. Installed below smooth,flat,horizontal ceilings and horizontal ceilings with beams. Includes ceilin•s with slopes up to and including 2/12(9.5°). List 3 Maximum Areas of Coverage? Minimum Water Supply Requirements? cULus4•smgs NYC 16'x 16'(4,9 m x 4,9 m) 14 gpm @ 7.2 psi(53 Umin @ 50 kPa) A1X — 18'x 18'(5,5 m x 5,5 m) 17 gpm @ 10.7 psi(64,4 Umin @ 73,7 kPa) A1X — I 20'x 20'(6,1 m x 6,1 m) 20 gpm @ 14.8 psi(75,7 Umin @ 102 kPa) A1X — installed below ceilingswith slopes6 up to and including a 4112(18.4°)pitch.Refer to Figure 1 below. Maximum Areas of Coverage6'7 Minimum Water Supply Requirements? {I cULus4 NYC 18'x 18'(5,5 m x 5,5 m) 17 gpm @ 10.7 psi(64,4 Umin(g 73,7 kPa) A1X — installed below ceilings with slopes6 up to and including an 8/12(33.7°)pitch.Refer to Figure 1 below. Maximum Areas of Coverage6.7 Minimum Water Supply Requirements? cULus4 NYC 16'x 16'(4,9 mx 4,9 m) 14 gpm @7.2 psi(53 Umin @50 kPa) A1X — 18'x 18'(5,5 m x 5,5 m) 18 gpm @ 12 psi(68,1 Umin @ 82,6 kPa) B1X — 18'x 18'(5,5 m x 5,5 m) 21 gpm @ 16.3 psi(79,5 Umin @ 112,4 kPa) CIX — 20'x 20'(6,1 m x 6,1 m) 20gpm @ 14.8 psi(75,7 Umin @102 kPa) B1X — 20'x 20'(6,1 m x 6,1 m) 21 gpm @ 16.3 psi(79,5 Umin @ 112,4 kPa) C1X — Approved Temperature Ratings Approved Escutcheons A-155°F(68°C)and 175°F(79°C) Approved Finishes X-Standard surface-mountedescutcheonsortheVi- B-155"IF(68°C) 1 -Brass,Chrome-Enloy®,White,and Black king,.Microfast® Model F-1 Adjustable Escutch- C-175°F(79°C) eon , or recessed with the Viking Micromatic® Model E-1 or E-2 Recessed Escutcheon Footnotes 1 Metric K-Factorshown isforusewhen pressure is measured in kPa.When pressure is measured in BAR,multiplythe metric K-Factorshown by 10.0. I 2 Base part number shown.For complete part number,refer to Viking's current price list. 3This chart shows the listings and approvals available at thetime of printing.Otherapprovals may be in process.Checkwith the manufacturerfor any additional approvals. 4 Listed by Underwriter's Laboratories,Inc for use in the U.S.and Canada. 5 Listingsare for residential occupancieswith smooth,flat,horizontal ceilings or horizontal ceilings with beams.Includesceilings with slopes up to and including a 2/12(9.5°)pitch.(For beam ceiling design criteria,refer to Table 2 and Figures 2A through 3D on pages 1401-m). 6Areas undersloped ceilings must be measured along theceiling slope.Actualfloorcoverage in the horizontal plane undersloped ceilings will be less than the listed area of coverage. 7 For areas of coverage smaller than shown,use the"Minimum Water Supply Requirement"forthe next larger area listed.Flows and pressures listed are per sprinkler. 6The Viking Microfast®Model F-1 Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible ele- ment of the sprinkler to be recessed behind the face of the wall or ceiling. \ �.���. Listed areas of coverage correspond to areas measured �7 417 along the ceiling slope.(For sloped ceiling installations, 11 ii N�� Refer to the \ :; �:., d ; actual floor coverage in the horizontal plane under Approval Chart : 1411�::�•ii: C:a sloped ceilings will be less than the listed area.) th above for maximum (�N:f�:'y��:11�n•••�pi:.� •• �• ceiling slope. ?:r•::�•� �•i•N��=iii� ' '�/itar'liiiyi:'�-lirit' Notes: :i:.ii•. ii•w�p:•-- tielt::;�::�. 1. Actual. installations sp may require multipleabeen srli !• show A single sprinkler installation has been Refer to the Approval ��a:t I shown for clarity. Chart above for listed �'� 2. For"cathedral'ceiling applications, install sprin- .• klers in a symmetrical mirror-image of Figure 1. areas of coverage. .4p.• .•�.�.�.�.�` / 3.For areas of coverage smaller than the listed ar- c �� :�:p,,,, •:��.� eas, use the "Minimum Water Supply Require- :.•O.....i❖.s ments"for the next larger listed"sloped"spacing. J.4.4. . •4. l P 0.a 4°O❖00.• Refer to the Approval Chart above. • .ppip•.�••. PP .•mop. p Figure 1:Installation Instructions-Sloped Ceilings VIXR.EX5953 -Cross-linked Polyethylene(PEX)Sprinkler Pipe and Fittings Page 1 of 2 Online Certifications Directory VIXR.EX5953 Cross-linked Polyethylene (PEX) Sprinkler Pipe and Fittings Page Bottom Questions? Ilreviells1 Cross-linked Polyethylene (PEX) Sprinkler Pipe and Fittings Guide Information REHAU INC EX5953 1501 EDWARDS FERRY RD PO BOX 1706 LEESBURG, VA 20177 USA PEX pipe and fittings of the following types and sizes for a rated pressure of 130 psig: Description Size(s) In. RAUPEX Non-barrier Pipe 3/4, 1 90 Degree Elbow, Coupling,Plug, Sleeve, 3/4, 1 Tee Copper Manifold Fitting(24 ports 1, 1-1/4, 1-1/2,2 x 3/4; 2 x 1 maximum) Female Copper Adapter 3/4 x 3/4, 1; 1 x 3/4, 1 Female Threaded Adapter 3/4, 1 Male Copper Adapter 3/4 x 3/4, 1; 1 x 1; 1 x 1-1/4 Male Threaded Adapter 3/4 x 3/4, 1; 1 x 1 Reducing Coupling 1 x 3/4 Reducing Tee 3/4 x 3/4 x 1; 1 x 3/4 x 3/4, 1; l x l x 3/4 Sprinkler Adapter Tee 3/4 x 3/4 x 1/2; 1 x 1 x 1/2 Female Copper Adapter 3/4 x 1/2 .../showpageltml?name=VIXR.EX5953&ccnshomitle=Cross-linked+Polyethylene+(PEX)+Sprinkler+Pipe+am5/13/03 VIXR.EX5953 - Cross-linked Polyethylene (PEX) Sprinkler Pipe and Fittings Page 2 of 2 Reducing Coupling 3/4 x 1/2 Reducing Tee 1/2 x 1/2 x 3/4; 3/4 x 1/2 x 1/2, 3/4; 3/4 x 3/4 x 1/2; 1 x 1 x 1/2 The pipe and fittings are for use in accordance with the manufacturer's installation and design manual dated April 2003. Page Top Notice of Disclaimer Questions? ` previous page ! UL Listed and Classified Products UL Recognized Products Certified for Components Canada This page and all contents are Copyright®2003 by Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service.Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service.Always look for the Mark on the product. .../showpage.html?name=VIXR.EX5953&ccnshorttitle=Cross-linked+Polyethylene+(PEX)+Sprinkler+Pipe+an 5/13/03 cb.../\ 1.\ 0 N � to w w a Q� a ___,\_,$)....Q.2.:i ` oe 28 lh It b.! sJ _ 34'-Oafs° 20 O" 4'-O� 4' 0441 20'-0" 4'-0%4" SW x 4' �il 6' �II / 4'-1" /2' 1t"DicYa /2'-O" 16' O" 2'-0" / u u �� \ \ 4 z / e'-6" it, 3'-0" / UP PORCH 0 z 3'-O" 1 4' 2" / 3'-0" x 3'-0" I Q a \ —� a \ 3_o" r \ \ O r OlO Ii-QU` � QI - - Aril ink i__ O n I REk r -el 0) REAR /� el -I u- O I HWT I -el C O In •1-r t co _ S.D. LL �—� 4 �i.® � 10'-2° I. BAT Li r 4 — \ ,� ENTRY o ? N-- 4 ; KITCHEN L\ x 4 9'-O Q __ FANI P. FURN O Q Q m 9 - Y t0 / ry —� 0 a, L 4? IPAN j m / 3-4 / lIeLi ^ WALL ANGLES �I, N a HANDRAIL r L 1 „n U 60 DEG. '?' \ e36" THIS $'-3" 3'-61, N m Y SIDE OF \ / \ / / \ EXISTING WALLS LK WC Di STAIRWAY " 2' B" 3' Sh" —N r N z, Q 5' ai 'n WALL • • //N x STORAGE =la 5'-3" F x t DOWV I UNDER _ is `� 2'-I" / _ -I! STAIR Q Cr: 4 \ \ lam - _ _ �� _ ' \ -� \ \ \ ` ,� EXISTING WALLS t o Th WALL OPENIFCNI HEADER ER N G S.D 4 O!5 6� CASEMENT 4'-O" _ Y P EGRESS M / T (B.UJ ,n 45.'D• WINDOW H s T i / 4'-`8' / OFFICE i T° 4 Q + 3 c x BEDROOM 2 4 OFFICE _ n S 7 _mil' pi {n 3 r- �t-- rn �- 1 , co r 14' 1" , SUN BEAM * / 4-0„ \ TUBES =� of ON 5 ' ` NT 0 v / 12' 3" / SUN TUBES 0 ti o J 1 / - -in ADD -11 411 (NxWINDOW m Si "�N OFFICE _� z _I L.: Q mlN '� Q, {1 gr 6O" x2O„ 4`Z �_ 4 BEDROOM I - \ = BEAM If i II . ` INTERIOR WINDOW T II -./ LIVING ROOM 4 \— 4 j _ ,Is' B" ,h 7 - ;n I I I I tr- CONFERENCE II 11 WAITING WITH / 12-B ry I ENTRY I 9 REPLACE EXISTING 9'-10'h° DOUBLE SGLAZING NEW WINDOW ry-410 L II'-5" I I IIN NEW FRAMES c(� NEW WINDOW SIZE FORWRAP'� I v' \ I Z SIZE I ..�.�r� I EGRESS Iw \ BEAMS WITH O 3b„ r4b' N \ \ \ U \ I • _El 11 \ 2LAYERSOF 3. 6" r 4'.b^ 3' O'' x 5-0" '. O" x 5' O" n 5/8 TYPE x GWB 0 ADD SECOND POSTII— e @IH BESIDE EACH EXISTING S 4 m O LANDING in 7 ZI PORCH (NOT STRUCTURAL REQ'TJ O ill W I I o ?]-±- \ o 0 111 El 6 " 1 -RAILING REBUILD STEPS CO ....._____....--------AUD HANDRAILS a 36" CP UPPER FLOOR AREA 998 SF / 5'-0" / \ 9 EXISTING WALLS 2x4 BALLOON FRAMING 3 \ PROVIDE FIRE BLOCKING PER CODE NEW EXTERIOR WALLS 2x6 STUDS w 10'-Ilh" / 6 -0" / 10'-IIh" / j I i 26' 3° 11 �� N t'• , 28-IIh" iF a f U) v, UPPER FLOOR PLAN THESE DRAWINGS ARE PROVIDED BY 4 RICHARDSON ARCHITECTURE PLANNING SCALE: I/4" • II-OH TOTAL MAIN FLOOR AREA 998 SF 101/4 FOR THE PURPOSE OF CONSTRUCTING A SPECIFIC HOUSE OR BUILDING(SJ IN A NET SQ. FT, OF OFFICES 371 SF /R SPECIFIC LOCATION NOTEDHEREIN. ANY OTHER USE, IN WHOLE OR IN ANYMAIN FLOOR PLAN PART WITHOUT WRITTEN PERMISSION5 Si OF THE ARCHITECT, AND AGREED UPON COMPENSATION FOR SUCH USE IS STRICTLY SCALE: I/4" I'-O'1 PROHIBITED, THE ARCHITECT ASSUMES • NO RESPONSIBILITY OR LIABILITY FOR SUCH UNAUTHORIZED USE AND SHALL BE ENTITLED TO COMPENSATION THEREFORE.IIIIIMMIIIIIII /�'� W THIS LINE IS I" LONG WHEN ENTIRE SHEET IS PRINTED ORT SIZE. IF SHEET IS ITEMSENLARGEDO REDUCED,ILLTHE SCALE ALMS S THE SHEET DIMENSIONS.NOT BE DOACCURATE.T ALWAYS USE GD RWIN DO NOT RELY ON SCALING THE DRAWINGS. C2005 RICHARDSON Archltectwe 4 Planning Anacortee. Washington \7��