Loading...
HomeMy WebLinkAboutPermit File BLD-2019-0835 1019 10th Street C3 City of Anacortes Invoice/Permit#: BLD-2019-0835 904 6th Street P.O.Box 547 Applied date: 12/27/2019 Issue date: 12/27/2019 ', .•• 0! Anacortes, WA 98221-0547 Expire date: 06/24/2021 'g/ (360) 293-1901 Job Address: 1019 10TH ST Permit Type: Mechanical Permit ANACORTES WA 98221-4139 Project: APN: P55102 Remarks: Replace 2 natural gas furnaces for the same. Owner: ANACORTES CHRISTIAN REFORMED C Contractor: DK SYSTEMS INC. Address: 1019 10TH ST Address: PO BOX 886 ANACORTES WA 98221-4139 BURLINGTON WA 98233-0630 Phone: Phone: (360) 755-1555 License#: General Information: Fees: #Forced Air Furnace> 100K 2 Mechanical Permit Fees 59.90 Total Calculated: 59.90 Deposits/Receipts: 0.00 Total Due: 59.90 Permits and Insp...- BLD-2019-0835-2020 019531-0003 Lee Mosh... 01/02/2020 11:01AM 11499-DK SYSTEMS INC. SI MOM AND VOID IF WORK OR ON AUTHORIZED IS NOT MMENCED WITHIN 80 DAYS, OR IF MENCED. I PE �JCTI1 NIF OR WT RK I HAVE READ AND ED EXAMINED THIS APPLICATION IANDONED FOR A A D KNOW THE SAME TO BEOTRUE AND CORRECT.IOD OF 180 DAYS AT ANY TIME AFTER WORK ISALLCOLn PROVISIONS DErLAWSONEDIIIIiRDINANCES969VERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHET _ SPECIFIED HEREIN OR NOT, THE (s *OF-A-PERMITi OES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL PROV IONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. SIGNATURE OF OWNER OR AUTHORIZED AGENT ISS - 11R@PCITFR (2LD- Z.a ici - 6gss , DEC 27 2019 46 PLANNING COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT 'OF ANA(`)t-i :UMBING & MECHANICAL PERMIT APPLICATION Mailing Address: P.O. Box 547, Anacortes, WA 98221 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 PLEASE REFER TO THE PLUMBING&MECHANICAL PERMIT CHECKLIST FOR SUBMITTAL REQUIREMENTS PROJECT ADDRESS(Street,Suite#) :1019- 10th Street PARCEL(S)#: P55102 Anacortes Christian Reform Church Subdivision/Lot#: RESIDENTIAL ❑ COMMERCIAL NI APPLICANT: Phone: D.K. Systems,Inc. 360-755-1555 Address(Street,City, State,Zip): Email Address: PO Box 886/962 S. Spruce Street dulce@dksystemsinc.com PROPERTY OWNER: Anacortes Christian Reformed Church Phone:360-293-5104 BJ & Sharon Middleton Address(Street,City, State,Zip): Email Address: bjsmiddleton@gmail.com 1019 10TH ST,Anacortes,98221 CONTACT PERSON: Phone: Dulce Herrera 360-755-1555 Address(Street,City, State,Zip): Email Address: PO Box 886/962 S. Spruce Street dulce@dksystemsinc.com CONTRACTOR:* Phone: D.K Systems,Inc. 360-755-1555 Address(Street,City, State,Zip): Email Address: PO Box 886/962 S. Spruce Street dulce@dksystemsinc.com *All Contractors&subcontractors must have a valid City of Professional License#: Exp.Date: Anacortes business license prior to doing work in the City. DKSYSI*982L1 06/21/2020 Contact the City's Finance Department at(360)299-1968. BusinessLicense#: Exp.Date: 602204164 05/3 1/2020 Is this work, associated with another project? Yes ❑ No l If yes,specify: PROPOSED WORK: (2)Like for Like Furnace Replacement I declare under penalty of perjury that the information I have provided on this form/application is true,correct,and complete,and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Anacortes. Print Name: Dulce M.Herrera,Project Coordinator Owner ❑ Agent ® (specify):D.K.Systems,Inc. Signature: D --e- pi/m/La/La- Date: 12/26/2019 Anacortes Christian Church - 1019 - 10th Street MECHANICAL: Equipment Type: Appliance/Equipment Information(new and relocated): Total#: Furnace: Gas#:2 Elec#: Other#: Location(s): 2 Wall Heater:Unit Heaters Gas#: Elec#: Other: #: Location(s): Gas Water Heater: #: Location(s): Heat Pump: Elec#: Other#: Location(s): Air Conditioner/Handler: Elec and Gas#: Other:#: Location(s): Radiant/Hydronic Heating: Gas#: Elec#: Other:#: Location(s): Exhaust Fans: Bath#: Laundry#: Kitchen#: Other#: Range Hood: #: Type 1 or 2(Circle which one) Location(s): Fireplace: Gas#: Elec#: Other:#: Location(s): Clothes Dryer&Duct: Gas#: Elec#: Other: #: Location(s): Stove/Range/Oven: Gas#: Elec#: Other: #: Location(s): Refrigeration Unit: Elec#: Other:#: Location(s): Gas Piping/Outlet(s): #: Location(s): Boiler: Gas#: Elec#: BTUs: Location(s): Other:Outside Air Systems #: Location(s):Please see plans TOTAL MECHANICAL OUTLETS: 2 PLUMBING FIXTURES: Fixture Type(new and relocated): Total#: Fixture Type(new and relocated): Total#: Water Closet(Toilet): Refrigerator water supply(for water/ice dispenser): Kitchen Sink: Pressure Reduction Valve/Pressure Regulator: Utility Sink: Water Service Line: Tub: Water Piping: Hand Sink: Clothes Washer: Shower: Electric Water Heater: Tank-less? Yes ❑ No 0 Dishwasher: Backflow Prevention Device: Urinal: Hose Bib: Floor Drain/Floor Sink: Drinking Fountain: Hydronic Heat in: Floor ❑ Wall ❑ Grease Interceptor: Other: Other: TOTAL PLUMBING FIXTURES: Y } PLANNING, COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT PLUMBING AND MECHANICAL PERMIT CHECKLIST Mailing Address:P.O. Box 547, Anacortes, WA 98221 Office Location: 904 661 Street, Anacortes WA 98821 Phone: (360) 293-1901 PROJECT ADDRESS: 1019 - 10th Street -Anacortes Christian Reformed Church Plans shall be of sufficient clarity to indicate the location,nature, and extent of the work proposed, and conform to the provisions of the adopted International Codes and City Ordinances. PERMIT TYPE: o oPJ Oo = SUBMITTAL REQUIREMENTS: e, The number indicates the number o f b 0 * copies for submittal(if applieable). it fD A+ �Qf X Plumbing&Mechanical Permit Application 1 1 1 X Mechanical Plans C:\ 0 0 0 Structural Calculations 0 0 0 State Non-Residential Energy Code Compliance Form 1 0 0 0 Manufacturer's Specifications/Cut Sheets 0 1 0 Elevation View for Roof Mounted Equipment �1w:'" 0 1 0 Plumbing Plans 0 0 1 0 Listed & Tested Fire Stopping Assemblies 0 0 1 0 Permit Fee ✓ ✓ �/ V NOTES: 1. Handouts and standard details may be found on the City's Planning, Community, &Economic Development website or can be obtained at city hall during normal business hours. 2. Plans, calculation, &reports prepared by state licensed architects or professional engineers must be stamped and signed by the design professional. 3. If installing a backflow prevention device, it will need to pass test results of which will need to be submitted-to-the city for review. Gas Furnaces Air RGPS Series i keem NEW Furnaces The new degree of comforts" RGPSI5EARJR Upflow/Horn 80% 5Ton Bldr Model Furnace - Serial #SF121400822 RGPSI5EARJR - Upflow/Horz 80% 5Ton Bldr Model Furnace - Serial #SF121400824 Rheem Value Series Upflow/Horizontal Gas Furnace RGPS- Series 80% A.F U.E.t Input Rates 50-150 kBTU y.. .. �Eguaku OE A} l tA.F.U.E.(Annual Fuel Utilization Efficiency)calculated in accordance with Department of Energy test procedures. • The Rheem Value Series line of upflow/horizontal gas • Left or right side gas and electric inlet connections allow furnaces are designed for utility rooms, closets, alcoves, quick and simple change. or attics. Because of the model's low-profile 34 inch • Direct spark ignition with remote sense, features a integrated [864 mm] height, the upflow model can also be used to board with an electronic air cleaner hookup. satisfy most applications that traditionally call for a horizontal furnace. • Prepaint galvanized steel cabinet. • The design is certified by CSA International. • A slow-open gas valve and a specially designed draft inducer motor make it one of the quietest furnaces on the market • Unique solid door design leads to quiet operation. today. • Patented heat exchanger, constructed of aluminized steel for the • Grab-holes in doors to aid in easy door removal and maximum in corrosion resistance and thermal fatigue reliability. replacement. • Low profile "34 inch" [864 mm] design is lighter and easier to • A variety of cooling coils and plenums designed to use with handle, and leaves room for optional equipment. Rheem Value Series gas furnaces are available as optional • Convertible from upflow to horizontal left or right without field accessories. conversion. INTEGRATED HOME COMFORT FORM NO.G11-520 REV.1 Standard &Optional Equipment Air RGPS Series PATENTED HEAT EXCHANGER DRAFT INDUCER MOTOR 3 r - ) . 5 - .awe ; ! .w Y° §y':.' 4 • tr z i '' �. f, • 1 } ttii Si f t ��: XY, IN-SHOT BURNERS � ' ;h a l a s ., any; :, ' t.N rf,Z4k,<W,,, ,4,, ,,-,,',4 ./*44.>,;-'4.-Fek** '47, ' ''''''''' '2,,ar- / i -,:'',-4 ., , tr R.. ... y:-.,„- ,.. ., 1‘4, f-SSS �• x f Iva f) iti` xF t £ —. DIRECT SPARK IGNITOR w yl «, ' T ,1', �fs � $ , . f ,101k- t' -17::,,T., ,-.4t, ' 7., , , r; kef i R >a INTEGRATED L a Ai s FURNACE CONTROL f.,r, f •Z :.< 3 STANDARD EQUIPMENT OPTIONAL EQUIPMENT Completely assembled and wired; induced draft; pressure switch; Twinning Kit redundant main gas control; blower compartment door safety switch; Side and bottom filter frame assembly. Return air cabinet for all sizes. solid state time on/time off blower control; limit control; manual shut- NOTE: Furnace is not listed for use with fuels other than natural or L.P. off valve, pressure regulator for natural and L.P. (propane) gas; (propane) gas. transformer; direct drive multi-speed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for The complete terms of limited and other warranties are available at our air conditioning applications. (Please note: a thermostat is not sales office, or through local installer. included as standard equipment.) Flame sensor diagnostics. All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form. NOTE: For natural and L.P. (propane) gas models, standard hot surface ignition is 100% safety lockout type. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES INTEGRATED HOME COMFORT 3 '-"r Model Features/Physical Data & Specifications Air RGPS Series Model Features • The design is certified by CSA International. • Direct spark ignition with remote sense, features a integrated • Unique solid door design leads to quiet operation. board with an electronic air cleaner hookup. • Patented heat exchanger, constructed of aluminized steel for the • Prepaint galvanized steel cabinet. maximum in corrosion resistance and thermal fatigue reliability. • A slow-open gas valve and a specially designed draft inducer • Low profile "34 inch" [864 mm] design is lighter and easier to motor make it one of the quietest furnaces on the market handle, and leaves room for optional equipment. today. • Convertible from upflow to horizontal left or right without field • Grab-holes in doors to aid in easy door removal and conversion. replacement. • Left or right side gas and electric inlet connections allow quick and simple change. Physical Data and Specifications MODEL NUMBERS 05EAUER 07EAMER 07EAMGR 10EAMER 10EBRGR 10EBRJR 12EARJR 15EARJR RGPS-SERIES 05NAUER 07NAMER 07NAMGR 10NBRJR Input-BTU/Hr[kW] 2 50,000 [15] 75,000 [22] 75,000 [22] 100,000 [29] 100,000 [29) 100,000 [29] 125,000 [37] 150,000 [44] Heating Capacity BTU/Hr [kW] 1 41,000 [12] 60,000 [18] 60,000 [18] 80,000 [23] 80,000 [23] 80,000 [23] 99,000 [29] 119,000 [35] Heat Ext. Static Pressure [kPa] .10 [.025] .12 [.029] .12 [.029] .15 [.037] .15 [.037] .15 [.037] .20 [.05] .20 [.05] Blower(D x W) [mm] 11x6 11x7 11x7 11x7 11x10 11x10 11 x10 11x10 [279 x 152] [279 x 178] [279 x 178] [279 x 178] [279 x 254] [279 x 254] [279 x 254] [279 x 254] Motor H.P.-Speed- 1/2-4-PSC 1/2-3-PSC 1/2-3-PSC 1/2-3-PSC 1/2-3-PSC 3/4-3-PSC 3/4-3-PSC 3/4-3-PSC PSC Type [W] [373] [373] [373] [373] [373] [560] [560] [560] Motor Full Load Amps 6.8 5.8 7.9 7.1 7.9 9.5 9.5 9.5 Heating Speed Med-Low Med Med Med Med Low Low Low Cooling Speed High High High High High Med Med Med Cooling CFM @.5"E.S.P. 1200 1200 1600 1200 1845 2060 2115 2080 (Nominal) [Us] [566] [566] [755) [566] [871] [922] [998] [982] Max. E.S.P. (In.W.C.) [kPa] 0.5 [.12] 0.5 [.12] 0.5 [.12] 0.5 (.12] 0.5 [.12] 0.5 [.12] 0.5 [.12] 0.5 [.12] Temperature Rise Range°F 25-55 35-65 25-55 45-75 30-60 30-60 35-65 50-80 [°C] [13.9-30.6] [19.4-36.1] [13.9-30.6] [250-41.7] [16.7-33.3] [16.7-33.3] [19.4-36.1] [27.8-44.4] Max. Outlet Air Temp. °F 155 165 155 190 170 170 180 190 [°C] [68.3) [73.8] [68.3] [87.7] [76.6] [76.6] [82.2) [87.7] Approx. Shipping Weight(Lbs.) 85 105 105 115 120 120 140 150 [kg] [39) [48] [48] [52] [54] [54] [63] [68] Standard Filter(In.) 153/4 x 25 153/4 x 25 153/4 x 25 153/4 x 25 191/4 x 25 191/4 x 25 223/4 x 25 223/4 x 25 [mm] [400 x 635] [400 x 635] [400 x 635) [400 x 635] [489 x 635] [489 x 635] [578 x 635] [578 x 635] Return Air Cabinets C14B C17B C17B C17B C21B C21B C24B C24B (Opt.) RXGR- (2) 12 x 16 (2) 12 x 16 (2) 12 x 16 (2) 12 x 16 • (2) 20 x 16 (2) 20 x 16 (2) 24 x 16 (2) 24 x 16 Filter Size [mm] [305 x 406] [305 x 406] [305 x 406] [305 x 406] [508 x 406] [508 x 406] [610 x 406] [610 x 406] AFUE-N.S.I. Models CO 80.0% 80.0% 80.0% 80.0% 80.0% 80.0% 80.0% 80.0% NOTES: All models are 115V,60HZ, 1 Ph. Gas connection size for all models is 1/2" [12 mm] N.P.T. 10 In accordance with D.D.E.test procedures. O See Conversion Kit Index Form for high altitude derate. [ ] Designates Metric Conversions INTEGRATED HOME COMFORT Model Number Identification Air RGPS Series Model Number Identification R G P S - 07E A M G R Rheem Gas P = Upflow/ Design Series Heating Input Designation Variations Blower Designation [mm] Heating & Cooling Fuel Furnace Horizontal s = 2nd Electric A = Standard U = 11 x 6 [279 x 152] Designation R = Natural Gas - Multi- Design Series Electric Ignition Input Cabinet M = 11 x 7 [279 x 178] E = 1100-1300(3R) CSA - Positional Ignition NOx BTU/HR [kW] B =Wide R = 11 x 10 [279 x 254] G = 1500-1700(4R) United States Tier III Cabinet J = 1900-2100(5R) & Canada 05E 05N 50,000 [15] (North American) 07E 07N 75,000 [22] 10E 10N 100,000 [28] 12E 12N 125,000 [37] 15E 15N 150,000 [44] [ ] Designates Metric Conversions INTEGRATED HOME COMFORT Dimensional Data --° Air RGPS Series ilpflio, ' Application 11/4" [32 mm] TOP BOTTOM SUPPLY RETURN 2317/32" 253/8" AIR 241/2" AIR [598 mm] [645 mm] [622 mm] _i L _ _ ,,,,,,, i __._.�� FLUE PIPE OPTIONAL ' ....CONNECTION AIR INTAKE PIPE CONNECTION C - E F A 9/16" [14 mm] —› 281/16" a,[713 mm] 19/32" 13/32" [15 mm] B [15 mm] 20'r —� -1-- 19/32" 3/4 rr I [19 mm) r [508 mmJ [15 mm] 0 0 t ° 2673/16" [681 mm] [-d 247h6" [621 mm] , GAS CONNECTION ( ) 13/13" DIA. [35 mm] 265/e" [676 mm] 34" - 265/8" [676 mm) 1 -1 ( ) [864 mm] r I 11 rr ( , ` ELECTRICAL CONNECTION 24 /32 2411/32" �� (HIGH VOLTAGE) e [618 mm] [618 rnm] 7/6" DIA. [22 mm] LOW VOLTAGEI 143/e" 143/3" I 15" I I [365 mm] [365 mm] '/e DIA. (22 mm] [381 mm] I OPTIONAL RETURN AIR CUTOUT I 111/2" 111/2" I (EITHER SIDE) FOR USE WITH I [292 mm] (292 mm] I EXTERNAL SIDE FILTER FRAME I I L I I J Y LEFT SIDE FRONT 23" [584 mm] RIGHT SIDE REDUCED CLEARANCE (IN.) [mm] MODEL A B C D E F LEFT RIGHT SHIP. WGTS. RGPS- SIDE SIDE BACK TOP FRONT VENT (LBS.) [Kg] 05 14 [356] 1227/32 [326] 105/8 [270] 111/2 [292] 17/8 [48] 0 4 [102] 2 0 1 [25] 3 [76] 6 [152] 11: 85 [38.6] 07 171/2 [445] 1611/32 [415] 123/8 [314] T 15 [381] 21/2 [64] 0 3 [76] ? 0 1 [25] 3 [76] 6 [152] '3; 105 [47.6] 10EA 171/2 [445] 1611/32 [415] 123/8 [314] T 15 [381] 21/2 [64] 0 3 [76] 2 0 1 [25] 3 [76] 6 [152] 115 [52.2] 10BRGR & 21 [533] 1927/32 [504] 141/8 [359] OD 181/2 [470] 21/2 [64] 0 0 0 1 [25] 3 [76] 6 [152] 120 [54.4] 1OEBRJR 12 241/2 [622] 2311/32 [593] 157/8 [403] I 22 [559] 21/2 [64] 0 0 0 1 [25] 3 [76] 6 [152] 3; 140 [63.5] 15 241/2 [622] 1 2.311/32 [593] 157/8 [403] ?; 22 [559] 21/2 [64] 0 0 0 1 [25] 3 [76] 6 [152] 150 [68] NOTES: T May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter. OO May be 0" [0 mm] with type B vent. Oa May be 1" [25 mm] with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code,ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes. [ ] Designates Metric Conversions 6 INTEGRATED HOME COMFORT Dimensional Data ') Air RGPS Series VOIrrigantal Application 5/e" [16 mm] TOP VIEW 20" [508 m"m] 247/16" 265/8„ 281/16" [621 mm] [676 mm] [713 mm] 13/e" DIA. [35 mm]� 7/8" DIA. [22 mm] L— r 71e" DIA. [22 mm] D / /4/ Yi 7 314 rr 111/2" [19 mm] —[292 mm)- 143/e" [365 mm] 2411/32" [618 mm] 5/e„ [16 mm] 34" a/a" [19 mm] [864 mm) 1 2317/32 [598 mm] it -Fr ° S.A. A B t IC R.A. E O LEFT END FRONT 5/e„ 241/2" F [16 mm] BOTTOM END [622 mm] 257/16" �' 2411/32" [618 mm] [645 mm] I .o143/e"[365 mm] 111/2" [292 mm] [ GASI 4\44t\L_ LOW VOLTAGE WARNING CONNECTION ELECTRICAL THIS FURNACE IS NOT APPROVED CONNECTION OR RECOMMENDED FOR HORIZONTAL APPLICATION OR INSTALLATION 213/16" [681 mm] [676 mm] ON ITS BACK, WITH ACCESS DOORS FACING UPWARDS. t LEFT VIEW Dimensional Data: Horizontal Model • REDUCED CLEARANCE (IN.) [mm] MODEL A B C D E F RGPS- LEFT RIGHT BACK TOP FRONT VENT SHIP. WGTS. SIDE SIDE (LBS.) [Kg] 05 14 [356] 1227/32 [326] 105/8 [270] ;D; 111/2 [292] 17/8 [48] 0 4 [102] 0 1 [25] 3 [76] 6 [152] 85 [38.6] 07 171/2 [445] 1611/32 [415] 123/8 [314] , . 15 [381] 21/2 [64] 0 3 [76] 0 1 [25] 3 [76] 6 [152] 7 105 [47.6] 10EA 171/2 [445] 1611/32 [415] 123/8 [314] ID 15 [381] 21/2 [64] 0 3 [76] 2 0 1 [25] 3 [76] 6 [152] CD 115 [52.2] 10BRGR & 21 [533] 1927/32 [504] 141/8 [359] (-1-, 181/2 [470] 21/2 [64] 0 0 0 1 [25] 3 [76] 6 [152] 3; 120 [54.4] 10EBRJR 12 241/2 [622] 2311/32 [593] 157/8 [403] C: 22 [559] 21/2 [64] 0 0 0 1 [25] 3 [76] 6 [152] 140 [63.5] 15 241/2 [622] 2311/32 [593] 157/8 [403] 22 [559] 21/2 [64] 0 0 0 1 [25] 3 [76] 6 [152] 2 150 [68] NOTES: 10 May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter. May be 0" [0 mm] with type B vent. OO May be 1" [25 mm] with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code,ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes. [ ] Designates Metric Conversions INTEGRATED HOME COMFORT --°D Air Blower Performance Data —0 RGPS Series Blower Performance Data MODEL BLOWER MOTOR CFM [Lis]AIR DELIVERY NUMBER BLOWER EXTERNAL STATIC PRESSURE INCHES [kPa]WATER COLUMN RGPS- SIZE H.P. SPEED SERIES [mm] [W] .1[.02] .2[.051 .3[.07] .4[.10] .5[.12] .6[.15] .7[.17] LOW 675 [319] 655 [309] 635 [300] 610 [288] 585[276] 555[262] 520[245) 05EAUER 11 x 6 1/2 MED-LO 950 [448] 930 [439] 905 [427] 880 [415] 860[406] 830[392] 800[380] 05NAUER [279 x 152] [373] MED-HI 1115 [526] 1090 [514] 1070 [505] 1040 [491] 1015[479] 985 1465) 945[446] HIGH 1270 [599] 1250 [590] 1225 [578] 1200 [566] 1165[550] 1130[533] 1085[512] 07EAMER 11 x 7 1/2 LOW 1093 [563] 1066 [503] 1039 [490] 1008 [476] 977[461] 941 [444] 905[427] 07NAMER [279 x 178] [373] MED 1241 [586] 1212 [572] 1183 [558] 1150 [543] 1118[528] 1076[508] 1033[487] HIGH 1393 [657] 1359 [642] 1326 [626] 1293 [610] 1259[594] 1214[573] 1169[552] 07EAMGR 11 x 7 1/2 LOW 1245 [588] 1220 [576] 1195 [564] 1165 [550] 1135[536] 1105[522] 1065[503] 07NAMGR [279 x 178] [373] MED 1555 [734] 1515 [715] 1475 [696] 1435 [677] 1395[658] 1350[637] 1300[614] HIGH 1810 [854] 1755 [828] 1705 [805] 1645 [776] 1585[748] 1530[722] 1470[694] LOW 1050 [496] 1040 [491] 1030 [486] 990 [467] 960[453] 920[434] 890[420] 10EAMER [279 x 78] [373] MED 1220 [576] 1195 [564] 1160 [547] 1140 [538] 1105[522] 1065[503] 1020[481] HIGH 1410 [665] 1380 [651] 1345 [635] 1300 [614] 1255[592] 1205[569] 1150[543] LOW 1295 [611] 1275 [602] 1250 [590] 1225 [578] 1195[564] 1165[550] 1135[536] 10EBRGR [279 x 254) [373] MED 1645 [776] 1615 [762] 1580 [746] 1550 [732] 1510[713] 1465[691] 1425[673] HIGH 2045 [965] 2000 [944] 1955 [923] 1905 [899] 1845[871] 1785[842] 1720[812] 10EBRJR 11 x 10 3/4 LOW 1645 [776] 1615 [762] 1580 [746] 1550 [732] 1510[713] 1465[691] 1425[673] 10NBRJR [279 x 254] [559] MED 2045 [965] 2000 [944] 1955 [923] 1905 [899] 1845[871] 1785[842] 1720[812] HIGH 2320[1095] 2260[1067] 2200[1038] 2130[1005] 2060[972] 1985[937] 1910[901] LOW 1645 [776] 1635 [772] 1615 [762] 1590 [750] 1560[736] 1520[717] 1470[694] 12EARJR [279 x 254] [559] MED 2050 [967] 2015 [951] 1980 [934] 1935 [913] 1885[890] 1835[866] 1775[838] HIGH 2365[1116] 2310[1090] 2250[1062] 2185[1031] 2115[998] 2035[960] 1950[920] LOW 1620 [765] 1595 [753] 1570 [741] 1545 [729] 1515[715] 1480[698] 1440[680] 15EARJR [279 x 254] [559] MED 2010 [949] 1985 [937] 1960 [925] 1915 [904] 1850[873] 1800[850] 1730[816] HIGH 2340[1104] 2275[1074] 2215[1045] 2145[1012] 2080[982] 2010[949] 1940[916] Note:Recommended blower speeds are in bold. [ ]Designates Metric Conversions 8 - = INTEGRATED HOME COMFORT Accessories Air RGPS Series INTERNAL FILTER RACK FOR BOTTOM RETURN AIR CABINETS A I FILTER SIZE OR SIDE RETURN:RXGF-DA* IN.[mm] IN.[mm] Each order contains(1)one box of 10 filter racks supplied without RXGR-C1 4B 14 [356] (2)12 x 16[305 x 406] filters. RXGR-C17B 171/2[445] (2)12 x 16[305 x 406] *Filters available through PROSTOCK®. RXGR-C21 B 21 [533] (2)20 x 16[508 x 406] SIDE RETURN FILTER RACK:RXGF-CA RXGR-C24B 241/2[622] (2)24 x 16[610 x 406] BOTTOM RETURN FILTER RACK FOR UPFLOW APPLICATION:RXGF-CB WARNING:IMPORTANT NOTICE A SOLID METAL BASE PLATE(SEE TABLE)MUST BE IN PLACE WHEN THE FURNACE IS FILTER RACK FILTER SIZESt INCHES [mm] INSTALLED WITH SIDE AIR RETURN DUCTS.FAILURE TO INSTALLA BASE PLATE COULD MODEL RXGF-CA CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND RGPS- (SIDE) CREATE POTENTIALLY HAZARDOUS CONDITIONS. FURNACE BASE 05,07,IDEA 153/4 x 25 WIDTH SOLID BOTTOM BASE PLATE SIZE [400 X 635] IN.[mm] KIT NO. PLATE NO. IN.[mm] 153/4 x 25 14 [356] RXGB-014 AE-61874-01 115/8 x 239/is[295 x 598] 10EBRGR&10EBRJR [400 X 635] 171/2[445] RXGB-D17 AE-61874-02 151/6 x 239/16[384 x 598] 153/4 x 25 21 [533] RXGB-D21 AE-61874-03 185/8 x 239/16[473 x 598] 12,15 [400 x 635] 241/2[622] RXGB-024 AE-61874-04 255/8 x 239/is[651 x 598] tFilter racks are shipped without filters. A 1"[25.4 mm]filter maybe used. FOR HIGH ALTITUDES: `Designates"E"or"N". OPTION CODE FOR HIGH ALTITUDE: U.S.&Canada RXPF—F01 and F02 None required for high altitudes. FOSSIL FUEL KIT—is for use with Rheem Value Series Heat Pumps HIGH ALTITUDE CONVERSION KITS:U.S.&Canada and air furnaces.RXPF-F02 meets NA requirements. None required for high altitudes. 80+HIGH ALTITUDE INSTRUCTIONS RXGP—F03 CAUTION:Always follow National Fuel Gas Code(NFGC)guidelines TWINNING KIT—is for parallel operation requirements. when converting for high altitudes. High altitude option codes are not required for these models. However,the burner orifice size needs to be recalculated and verified ACCESSORY RETURN at elevations above 2000 ft.See Installation Instructions for more AIR CABINETS information. Return Air Cabinets may be installed on either side NOTE:For Canadian installations only,an optional derate(manifold application except RXGR-C24B (side application must be gas pressure reduction)method may be used to adjust the on side opposite gas and furnace for altitude.See Installation Instructions for more electrical connections). information.This optional method may NOT be used for U.S. installations. [ ]Designates Metric Conversions ,, 0 0 0 J> 14" -' A [356 mm] �� THE RXGR-C24B MUST ONLY BE INSTALLED ON THE SIDE OPPOSITE THE GAS AND ELECTRICAL CONNECTIONS. INTEGRATED HOME COMFORT 9 Limited Warranty Air FIGPS Series C Al T EM IS OF 11/[ C i 1 WARRANTY* Rheem will furnish a replacement for any part of this product Conditional Parts* (Registration Required) Ten (10) Years which fails in normal use and service within the applicable Heat Exchanger Twenty (20) Years period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. `lid' INTEGRATED HOME COMFORT