HomeMy WebLinkAboutPermit File BLD-2018-0075 1506 Latitude Circle (2) INSTALLED INSULATION CERTIFICATE
P.O Box 2921 Office:(360)424-5179
Mt.Vernon WA Fax (360)428-5081
MASTER .Nsm Arlohd it SERVICES 11 LC
We certify that the following residence has been insulated with the following materials:
Flat Attic Blow in VALUE R-49
Slope Ceiling Batts VALUE R-38
Exterior Walls VALUE R-21
Garage Ceiling Under Heat VALUE R-38
Crawl Space VALUE R-38
Address: 1506 Latitude Circle,Anacortes WA Certify by : Se g1.0' Lo-za-ti o-
North 48th L#11
Date Installed November 2019 Title Manager
ti it f1 r) i / .�
RResidential Building Air Leakage Test (Blower Door Test) Results.AV
Permit#: n('44.- 45* L*-
House address or lot number: 154 L0.�i .�r C`
City: Ain Ulf1)C -f,S Zip: q t
Cond. Floor Area (ft2): 2-C1S('.2 Age of house: 1 jr ci Ael
Source(circle one): Plans Estimated Measured
Results shall be reported as Air Changes per Hour at 50 Pascals (ACH50)and shall be calculated as follows:
ACH50= (CFM50 x 60)/Volume
Where:
CFM50= Blower door fan flow at 50 Pascal pressure difference
Volume=Conditioned Floor Area of the housing unit x ceiling height
Blower Door Test Result: 5 ACH50
2000 CFM@50Pa
Ring (circle one if applicable): Open A B C
Blower Door Fan Location: /4t(in Weather Conditions: Cl pt
✓I certify that these blower door results are accurate and determined using standard industryprotocol
Company Name: /t'�C1`jkc 14Ajtf`i n n Technician: L.t)Z.c4.r.0
Technician Signature: /75f--4- L Date: D ,2..D(W Phone Number: 7100 -42.H{—5 Fri
2015 Washington State Energy Code reference:
R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not
exceeding 5 air changes per hour.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50
Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report
of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing
shall be performed at any time after creation of all penetrations of the building thermal envelope.Once visual
inspection has confirmed sealing(see Table R402.4.1.1),operable windows and doors manufactured by small business
shall be permitted to be sealed off at the frame prior to the test.
tC0 MOEN Specifications
Buy it for looks. Buy it for life
al\
DESCRIPTION 100,
• Metal construction with various finishes identified by suffix
• Includes showerhead, arm,flange and diverter spout
OPERATION
0
• Handle operates counterclockwise through a 270° arc with off
at 6 o'clock and maximum hot at the 9 o'clock position. Shut off in
clockwise direction
• Adjustable temperature limit stop to control maximum hot water
temperature
• Pressure balancing mechanism maintains selected discharge
temperature to±3°
FLOW
• Showerhead is limited to 2.5 gpm (9.5 Umin) at 80 psi EVA' POST-TEMP•
• EP suffix models are limited to 1.75 gpm (6.6 Umin) at 80 psi Single-Handle Tub/Shower Trim Kit
• NH suffix models contain no showerhead g
CARTRIDGE
• 1222 cartridge design Models: T2131 series - valve trim only
• Nonmetallic/nonferrous and stainless steel materials T62131 (Bulk Packed 12 per carton)
• Accommodates back to back installations
STANDARDS T2132 series - shower trim only
• Third party certified to meet ASME Al 12.18.1/CSA B125.I and all T62132 (Bulk Packed 12 per carton)
applicable requirements referenced therein
• EP suffix models are third party certified to WaterSense$ T2133 series - tub/shower trim
• ADA 0 for lever handle T62133 (Bulk Packed 12 per carton)
WARRANTY Valves: 62300 series
• Lifetime limited warranty against leaks, drips and finish defects to 2500 series
the original homeowner
• 10 year limited warranty when used in a multifamily installation
• 5 year limited warranty when used in a commercial installation �tierSr•�
Visit www.moen.com/support for complete details and limitations `1,ra
• , i2EPA '
.4An nar
2'CC(s( 8m) EP Suffix
1-7/8'IPS(4,8mm) I+-
MAX WALL FACE OF STUD
` 1/2'MIN.CC(13mm) Models Only
3 1/2' FINISHED WALL LINE .
—(89mm)— I 5/8"MIN.IPS(16mm)
+- 7-13116' I
(199mm)
/ 1'•
' 3-1/2"(89mm)MAX. PLASTER GROUND
2-1/4"(57mm)MIN.
''.' • • --2-1/2'MAX.(63mm) 1 1/2'
_ DIAMETER I. (38mm)
7"(178mm) r' - - WALL •
ESCUTCHEON — OPENING / ,
I
DIAMETER '
4-1/2"(114mm) M 11.,q6.-6. I q,
;�1 WALL OPENING � �= CL (1981mm) IIIL
i---- 0 1 .
7-1/2" 11 1 .I - ' --- -1-3/8"(35mm) 1 3/8'
(191mm) l i
MIN — I' -- �� (35mmI
1 •
HOT ft COLD 45"(1143mm)/ PLASTIC
INLET INLET ' 48"(1219mm)-SHOWER 32"(813mm)TUB OR SURROUND
TUB SHOWER
2-112" 7' - i
(63mm) (178mm)
TUB RIM ' FLOOR" 1 FLOOR LINE —
THICK WALL APPLICATION THIN WALL APPLICATION
G) Nt•Pacem System
—
CRITICAL DIMENSIONS
(DO NOT SCALE)
FOR MORE INFORMATION CALL: 1-800-BUY-MOEN
T2133sp: Rev.4/17
www.moen.com
m 0 E N®
Specifications
1
FAUCET DESCRIPTION ...::\ii, 111\
• • Reflex'puildown system offers smooth operation,easy movement and
secure docking
• Metal construction with various finishes identified by suffix
• Quick conned system
• Pullout spray with 68"braided hose
• Flexible supply lines with 3/8"compression fittings
• High arc spout provides height and reach to fill or clean large
pots while pull out wand provides the maneuverability for cleaning or rinsing
• 360"rotating spout11110 bil
• Power clean spray
OPERATION
• Lever style handle
• Temperature controlled by 100°arc of handle travel
• Operates with less than 5 lbs.of force
• Operates in stream or spray mode in the pullout or retracted position
• When filling a vessel outside the sink,the pause feature conveniently stops the ARBOR
flow of water as the wand passes over the counter top
FLOW Single Handle High Arc
• Flow is limited to 1.5 gpm(5.7 L/min)at 60 psi Pulldown Kitchen Faucet
CARTRIDGE
• 1255'Duralast' cartridge for Single-Handle Faucets
STANDARDS Models: 7594 series
• Third party certified to IAPMO Green,ASME Al12.18.1/CSA 8125.1 and all
applicable requirements referenced therein
• Certified to NSF 61/9&372
• Meets CaiGreen and Georgia SB370 requirements NOTE:THIS FAUCET IS DESIGNED TO BE INSTALLED
• Complies with California Proposition 65 and with the Federal Safe Drinking Water Act THROUGH 1 OR 3 HOLES, 1-1/2" (38mm) MIN. DIA.
• The backflow protection system in the device consists of two independently GREEN
operating check valves,a primary and a secondary which prevent backflow ikAll
• ADA ® for lever handle
WARRANTY
• Lifetime limited warranty against leaks,drips and finish defects to the
original homeowner
• 10 year limited warranty when used in a multifamily installation
• 5 year limited warranty when used in a commercial installation 7-7/8"
Visit www.moen.com/support for complete details and limitations (199mm)
A15-1/2"
_ 5-1/2" (394mm) i
(140mm) 11
10-1/4'x 2-1/2' 8-1/4" ),\
(260mm x 64mm) , (210mm)
b 1/2° ESCUTCHEON 1 r I
(13mm)
(165mm) / "
l IL
i __ r _ •,
2-3/16" _ ._ICI 2-5/16°
(56mm) (58mm)
I 1 u ''
2-1/2"Max
Deck Thickness
1 -
b 29-1/2" (1111
F 3 (750mm) r C.
Tr
E.
CRITICAL DIMENSIONS
16 (DO NOT SCALE) A A
TO ORDER PARTS CALL: 1-800-BUY-MOEN
8/18 www.moen.com
k
3
Ug MOEN Specifications
Buy it for looks. Buy it for life'
DESCRIPTION
• Body-Acetal ,
• Int. o-ring- EPDM /'
• Ext.o-ring- Silicone
• Continuous temperature- 120 degrees F Max
• Continuous pressure-90 psi Max
FLOWr MOW
• Pressure compensating for constant flow from 20 to 80 psi
WARRANTY
• Warranted for 5 years against material or manufacturing Aerator
defects when used in commercial applications 1.0 gpm (3.8 I./min) max.
Model:316721
FOR MORE INFORMATION CALL: 1-800-BUY-MOEN
10/15 www.moen.com
gS