Loading...
HomeMy WebLinkAboutPermit File BLD-2019-0690 817 37th Street �1 '"�' Y 4 City of Anacortes Invoice/Permit#: BLD-2019-0690 904 6th Street :} Applied date: 10/18/201922 P.O.Box 547 Issue date: 10/22/2019 ,p` C&' Anacortes, WA 98221-0547 (360) 293 1901 Expire date: 04/19/2021 Job Address: 817 37TH ST Permit Type: Single Family Alteration/Repair Permit ANACORTES WA 98221-3463 Project: APN: P33118 Remarks: Install a solar PV system, 9.3 kw 30 mission solar 310 mods and 30 Enphase IQ7 inverters. Owner: PHILIP STEFFEN Contractor: WESTERN SOLAR INC. Address: 1314 27TH ST Address: 4041 HOME RD ANACORTES WA 98221-3809 BELLINGHAM WA 98226-9158 Phone: (360) 853-6500 Phone: (360) 746-0859 License#: General information: Fees: Building Valuation 4650 Building Permit Fee 111.25 Occupancy Group it-1 Plan Review Fee 72.31 State Building Code Fee Resi 6.50 Total Calculated: 190.06 Deposits/Receipts: 0.00 Total Due: 190.06 r1 --.i -n w .-- o -ti c -5 • -:, r r-- I-- a rn 51• < ID SJ 0 v} -s —, =, _ i cn .1:._ a r liI it. t...1 -.1 r.4 ►.. .. 4• — I-•• CI a, rh rl rt. .-i- I-- 1 I ill CI .t - I CI C., Imo- Z• I w I' !i• r 00m IJ co f wi rl', o-J ui to I... Ir. n (Ij •t L-1 1!1 T. _. 4. ;7i ; CT)-1-1 r- THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAY 6ig:IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMNtD!:/ I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL RROVI§JO4S OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR.NO1,5114E GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE P.T.e• - DNS OF ANY OTHEI STA1=1<; R LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. T. `J •-.�1 CI .., _.. ..,.. �I 1 1 c, ht SIGJi- TURE OF OWNER OR AUTHORIZED AGENT IS ED n •j. t•• act Plil, C) PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT RESIDENTIAL BUILDING PERMIT APPLICATION Mailing Address: P.O. Box 547,Anacortes, WA 98221 l'4111Citrc, Office Location: 904 6'h Street,Anacortes WA 98821 -„4 cos Phone: (360)293-1901, Fax: (360) 293-1938 PLEASE REFER TO THE RESIDENTL4L BUILDING PERMIT CHECKLIST BELOW FOR SUBMII I AL REQUIREMENTS PROJECT ADDRESS(Street,Suite#):817 37th ST Parcel(s)ti:P33118 Subdivision/Lot#: Project Valuation: S4650 APPLICANT:Cheryl Beadle/Western Solar Inc. Phone:360-746-0859 Fax: Address(Street.City.State,Zip): E-Mail Address: 4041 Home Rd.,Suite A.Bellingham,WA 98226 cheryl@westernsolarinc.COM PROPERTY OWNER:Philip Steffen Phone:360-853-6500 Fax: Address(Street.City.State.Zip): E-Mail Address: 817 37th ST,Anacortes, WA 98221 pip.steffen@grnail.corn CONTACT PERSON: Cheryl Beadle Phone:360-746-0859 Fax: Address(Street.City,State,Zip): 4041 Home Rd.,Suite A,Bellingham,WA 98226 E-Mail Address:cheryl@westernsolarinc.COM LENDING AGENCY: Phone: Fax: Address(Street,City.State,Zip): E-Mail Address: CONTRACTOR:*Western Solar Inc. Phone:360-746-0859 Fax: Address(Street,City,State,Zip): E-Mail Address: 4041 Home Rd.,Suite A,Bellingham,WA 98226 cheryl@westernsolarinc.com Professional License#: Exp.Date:04/25/2020 *All Contractors&Subcontractors must have a valid City of Anacortes CCWESTES*910J0 business license prior to doing work in the City. Contact the CiV's Business License P: Exp.Date:12/31/2019 Finance Department at(360)299-1968. 602258981 PROPOSED WORK: Install Solar PV System PROPOSED NEW SQUARE FOOTAGE: Basement SQ': Finished Basement: 0 Unfinished Basement 0 s'Floor SQ': Garage/Carport SQ': 2''Floor SQ': Deck/Covered Porch/Patio SQ': Fire Sprinkler: Yes 0 No 0 Lot Area SQ': Is construction associated with an accessory dwelling unit? Yes El No 0 I declare under penalty of perjury that the information I have provided on this forrnJapplication is true,correct,and complete,and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Anacortes. Print Name: Cheryl Beadle Owner 0 Agent PI(specify): Western Solar Inc. Signature: Date: cl to/ 115) Page 1 of 3 To Be Completed By the Applicant Project Address: 1 ST } Project Applicant: . 1 Er( IQ SO L -. a lit • C L S U-1 Applicant Email: C.1 I d S.1.00,s,d) r C. Phone No.: 3-CDO .1 ' °- Site Owner Name: PW1 I 1 p + e44- r\ PV System Description: • 4c C3 ) 1-ncski6N. a Icy ' gwag5 (30) Trp 7341,4 1AV ef3Q1S Determine if your project is eligible for an over-the-counter Permit (Check Yes or No) Yes No 1. PV System is designed and proposed for a detached single-family house, duplex or D townhome. a 2. PV System is designed for rooftop of house in general compliance with applicable codes. 3. Mounting system is engineered and designed for PV. g D 4. Rooftop is made from light weight material such as shingles. D 5. PV system will be permitted and pre-approved by Labor & Industries Electrical division. 6. To address uplift, panel are mounted no higher than 18" above the surface of the D roofing to which they are affixed. Except for fiat roofs, no portion of the system may exceed the highest point of the roof. 7. Total deal load of panels, supports, mountings, race ways, and all other kL<- appurtenances weight no more than one of the following. IF Yes, indicate which: No more than three and one half(3.5 pounds per square foot (PSF) © Frameless panels on at least 3/12 pitch roof weighing no more than four and one-half (4.5) PSF a Frameless panels on at least 5/12 pitch roof weighing no more than five (5.0) PSF 8. Supports for solar panels are installed to spread the dead load across as many D roof-framing members as needed to ensure that no point loads in excess of fifty (50) pounds are created. 9. Attachment to the roof is specified by the mounting system manufacturer. D 10. Panels are mounted no higher than the roof ridge or apex of roof (applies only to D pitched roofs). Comments: D By Checking this box, I certify that all of the information provided on this form is correct. if you answered yes to all of the above questions, your PV installation is eligible for an over-the-counter building permit. To apply please bring in this completed form to our permit center at City Hall for an over-the-counter permit. To be Completed By,Staff • Project is eligible for over-the-counter permit? o Yes 0 No CITY OF ANACORTES Notes: Exterior/Interior DC Condui LIC V,/^RKS DEPA to be labeled as: VV"" V ill )�ii n Solar, 310 Watt Photovoltaic Modules "Photovoltaic Conductors" APPROVEQ otal System Size: 9,300 Watts DC, 9.3 kWs Main Disconnect to be Identified as. � ..CEPTED PL>�33.17 V, Imp=9.345 A, Voc=40.12 V, Isc=9.76 A "Photovoltaic Power SBi�r�C IT #: p/� �,� J ' 'r Module Dimensions: 39.33" x 65.53" x 1.58" Prime Consultants Inc. Design meets requirenk446 S: O! 7 .T 7 ,�� dba. Western Solar Inc. WAC 51- re05 Installed per Manufacturer Recommendations 4041 Home Rd Ste A Section 605.11.1.1, 6.1i 6.?4ED BY: `� %� �+� oof�f-residence using flushmount Snap N Rack Bellingham, WA 98226 G SUBJECT TO FIELD INSPECTION. APPPIVED PLA nting System installed at 48" on center, LIC#: WESTES*91030 NSpremanufactured trusses at 24" o.c. SHALL NOT BE ALTERED WITHOUT A TKORIZATIIEts all City of Anacortes Structural Permitting Requirements Project Manager: Mission Solar 310W Modules 40.1 lbs per solar module x 30 modules = 1,203 lbs Eric Blatz 17.89 sqft per solar module x 30 modules = 536.7 sqft 4041 Home Rd Ste A 1,203 lbs/ 536.7 sqft = 2.24 lbs/sqft. Bellingham, WA 98226 Tel: 360-224-9839 18" ridge setback —\ Installing Electrician: Prime Consultants Inc. 1 /— 18° comp roof dba. Western Solar Inc. E_ 4041 Home Rd Ste A _ r" ems IlIPI .esi : �Gn _36" eve setback —\ iiiIEiji - - :■ - ::: ■: : -■■:' -- —■� ::■ :■ � ■■=R- LIC#: WESTES 872DD 111111 a 11111111111111111 E E1■■■own faisd - milli Client Name: L'zi/ilhyqit'ilii ■ ■r��i i■�i■�- ■ 9C-� ■9 ��i ■ '�=■.�i iC i■■3 riE 4-- __ Philip Steffen 7--■ ■ ■J■ : ■■■ ■ ■ .� ■ ■■ C ■ g 5■■■■. ■o■■■• _• du1 s. rIIi l M 2Ie. • NAaILt. A S U i ■ :imPA' - Lad p�.- 5 i-ri MEE— 1----- AnacortesWA 98221 q ::n ampn C �'1 : 6 ■C-,6 i■ CIC: ::Ck: _- _ _ r- ■ Project Size: �■ :i ■�■ iaFa� ,- . ■r.. no - c a •w ■ lii AM 9.3 kW PV System -�;; Fan M : 6 _ 6 ,�:.■ E : - E' 18�9 C. C.■ .� _ :...s y_ ■ ■::i■ g ■ :ii:: �� EC■w■ �55' 6 2 C__ Sales/Designer: ■u■■■ ■■■�: : ��i ■■�� •■■ ■ ■■ ■ Callum McSherry - _ Issue Date: — _ ` 9/26/19 K Roof Overview '‘ Notes: Exterior/Interior DC Conduit Runs to be labeled as: "Photovoltaic Conductors" Main Disconnect to be Identified as: Total PV Array Area: 536.7 sqft "Photovoltaic Power Source" Total Roof Area: N 2140 sqft Prime Consultants Inc. Roof Area of Array: 25% dba. Western Solar Inc. Design meets requirements of: 33% Rule Applies 4041 Home Rd Ste A WAC 51-54A-0605 PV System installed with 18"setback Bellingham, WA 98226 Section 605.11.1.1, 605.11.1.2 from ridges Parcel #P33118 LIC#: WESTES*91030 37th St Project Manager: Eric Blatz 4041 Home Rd Ste A Bellingham, WA 98226 Tel: 360-224-9839 20' Installing Electrician: Residence (new construction) Prime Consultants Inc. dba. Western Solar Inc. _ = 4041 Home Rd Ste A ExistingADU Bellingham, WA 98226 LIC#: WESTES*872DD 18" ridge setback Client Name: Philip Steffen 98' -4 10 — — _ PSE Meter& 817 37th St 1 _ PV System Anacortes, WA 98221 -=I = Disconnect _ Project Size: 36" eve setback _ = 9.3 kW PV System Sales/Designer: Callum McSherry Existing Garage N Issue Date: 26 8" 10/16/19 W E Site Plan S L ' 128' Prime Consultants it nc. dba. Western Solar Inc. 4-041 Nome Rd Ste A • Bellingham, WA 98226 „am. (30) Mission Solar, 310 Wait Photovoltaic Modules LiC#: WESTES*91030 S�` II-' ew Total System Size: 9,300 Watts DC, 9.3 kWs _ Vmp=33.17 V, I.mp=9.345 A, Voc=40.12 V, Esc=9.76 A Module Dimensions: 39.33" x 65.53" x 1.58" Project Manager: ?` � ". __` '/o — .a\ '. " Eric Katz Installed as (2) Strings of (15) Modules with 4041 Home Rd Ste A (15) Enphase IQ7 Microinverters in parallel Bellingham, WA 98226 Tel: 360-224-9839 anstalling Electrician: • - - - Prime Consultants E nc. ,..,_ ---� ....., .r dba. Western Solar inc. S` Erd` d 4041 Home Rd Ste A — Module PV Wire with MC4 Connectors Bellingham, WA 98226 LIC#: WESTES*872DD Enphase 3Q7 AC Interconnect Cables Black - L1, Red - L2 Primary PSE Utility Meter to be changed to Solar Net Meter \ Client Mame: Located TED Phillip Steffen \ ° -817 37th St. [ action Box o O Anacortes WA 98221 Project Size: (4) #10 TG-oun 9.3 kW PV System (1) #12 Ground r- (2) 20 Amp, 240VAC Solar interconnect Breakers Drawn by: (1 Amps max output per inverter) x (15 inverters in parallel) = (15 A) (1 5 A) x (1.25 NEC Safety' Factor) = (18.75 A Maximum output Current) Dana l-licicenbo tou�u, WSI Issue Date: i 9/28/2019 240VAC Sub-Array — Combiner Panel �- One Line Diagram vs1 AC (:Disconnect 200A 240VAC initiates rapid Shutdown _� Main Panel -r—T- Located T ED / (3) #8 THHM, ^ � (1) #10 Ground -8-rt-1- 1 ,0 0 1 40 Amp, 240VAC Solar Interconnect Breaker —I All conductors from rooftop junction box (1 Amp Peak Output) x (30 Microunveaters) = (30 A) to combiner are pulled through 3/4" ENT (30 A) x (1.25 NEC Safety Factor) = (37.5 A Maximum Output Current) raceways per MEC