HomeMy WebLinkAboutPermit File BLD-2019-0479 4907 Paisley Place iH g ' City of Anacortes Invoice/Permit#: BLD-2019-0479 904 6th Street Applied date: 07/26/2019 `'"" P.O.Box 547 Issue date: 0: Anacortes, WA 98221-0547 l (360) 293-1901 Expire date: 01/21/2021 z4 Job Address: 4907 PAISLEY PL Permit Type: Single Family Alteration/Repair Permit ANACORTES WA 98221-3119 Project: APN: P59906 Remarks: Install solar panels on roof of SFR. Owner: JANSON JOHN R Contractor: WESTERN SOLAR INC. Address: 4907 PAISLEY PL Address: 4041 HOME RD ANACORTES WA 98221-3119 BELLINGHAM WA 98226-9158 Phone: Phone: (360) 746-0859 License#: General Information: Fees: Building Valuation 3355 Building Permit Fee 97.25 Plan Review Fee 63.21 State Building Code Fee Resi 6.50 Total Calculated: 166.96 Deposits/Receipts: 0.00 Total Due: 166.96 THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHE ECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL TH OVISII NS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. c____1,Ny- .7 SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED Permits and Insp... - BLD-2019-0479 - 2019 019303-0044 Erin Wil... 08/05/2019 09:52AM 11057 - WESTERN SOLAR INC. BLD-2019-0479 Single Family Alteration/Repair Permit Payment Amount: 166.96 Transaction Amount: 166.96 CHECK: 002874 L -0 -2649 6V77 liii JUL 19(), PLANNING, COMMUNITY, &ECONOMIC DEVELOPME EPARTMENY / RESIDENTIAL BUILDING PERMIT APPLelirreptiliv CORTE.s Mailing Address:P.O. Box 547, Anacortes, W4 98221 'kTekilleeet•47 \1C0V- Office Location: 904 6th Street, Anacortes WA 98821 • Phone: (3m) 293-1901 PLEASE REFER M THE RESIDENTIAL BUILDING PERMIT CHECKLIST BELOW FOR SUBMITTAL REQUIREMENTS PROJECT ADDRESS(Street,Suite it): e PARCEL(S)#: 1490-7 Pc051e9 Mac P5T1-0(0 Subdivision/Lot : ,PROJECT VALUATION: $ APPLICANT; Phone: C Yu)1 gi-eoal Ave sityn o-r 3(0o-mico- OaS Address(Street,City.State,Zip): Email Address: Li 64- I 1-1-nrrve S.A.44e A, It;t\Sk‘tkrix 1177G C.I'verlethevl-trrt5tilo.r;INC.COAN., PROPERTY OWNER: I Phone: jC/1111 I 0.11 SO r\ 36,0 -219-817-7 Address(Street.City.State,Zip): Email Address: 9 9(ri a1etfLact, Nnosar4es ) ? 2.I X iirvibijithr&IYIST1.COM CONTACT PERSON. Phone: (Ave t greckel 3C,O--11-R0-6859 Address(Street,City,State,Zip): Email Address: 0141 +fume SAA;I-e I's i\tk atA WP% 99s22.G, Ch-c ini) 1.,./estrAN0 tafinc. C C'AN LENDING AGENCY: Phone: Address(Street,City,State,Zip): Email Address: CONTRACTOR:* Phone: WQSULSOI ( Bcpb----46:). 08c-9 Address(Street,City,State,Zip): Email Address: Ffrovz "?.,t 11:n61-0,r,MP,9g C l@ s4y r loxiv • cc Professional License#: Exp.Date: *Al(Contractors&Subcontractors must have a valid City of cctvESTESXcit63.a 41257 213 Anacortes business license prior to doing work in the City. Contact Business License ft; Exp.Date: the City's Finance Department at(360)299-1968. PROPOSED WORK: PROPOSED NEW SQUARE FOOTAGE: Basement SQ': U Finished Basement: El Unfinished Basement I"Floor SQ': Garage/Carport SQ': 2fid Floor SQ': Deck/Covered Porch/Patio SQ': Fire Sprinkler: ID Yes CI No Lot Area SQ': I declare under penalty of perjury that the information I have provided on this form/application is true,correct,and complete,and that lam the property owner or duly authorized agent of the property owner to submit a permit application to the City of Anacortes. Print Name: C, 'e 1 I3-e- o_. Owner 0 Agent Yqspecify): /Slt rA 11 14,..{ , 19 Signature: -7' 2 Page 1 of 5 IMPERVIOUS SURFACE AREA: Existing Impervious SQ`: New Impervious SQ': Total Disturbed Land/Soil SQ': Total Proposed: Cut: Fill: New hard surfaces(pervious&impervious) Land converted from native vegetation to lawn or landscaping SQ' Land converted from native vegetation to pasture SQ' MECHANICAL: Equipment Type: Appliance/Equipment Information(new and relocated): Total#: Furnace: Gas#: Elee#: BTU: Other#: Wall Heater: Gas#: Elec#: Other:#: Location(s): Gas Water Heater: #: Location(s): Heat Pump: Lice#: Other#: _. Air Conditioning: Elec#: Other#: Radiant/Hydronic Heating: i Gas#: Elec `: Other:#: Location(s): Exhaust Fans: � Bath#: Laundry#: Other: Range Flood: I #: Location(s): 1 Fireplace: Gas#: Elec#: Other:#: Location(s): Clothes Dryer&Duct: Gas#: Elec#: Other:#: Location(s): Stove/Range/Oven: Gas#: Elee#: Other:#: Location(s): Gas Piping/Outlet(s): #: Location(s): Boiler Gas#: Elec#: BTUs: Location(s): Other: /?: Location(s): TOTAL MECHANICAL OUTLETS: PLUMBING FIXTURES: Fixture Type(new and relocated): Total#: Fixture Type(new and relocated): Total#: Water Closet(Toilet): Refrigerator water supply(for water/ice dispenser): Kitchen Sink: Pressure Reduction Valve/Pressure Regulator: Utility Sink: Water Service Line: Tub: Water Piping: Hand Sink: Clothes Washer: Shower: Electric Water Heater: Tank-less? Yes © No ❑ Dishwasher: Baekflow Prevention Device: Hose Bib: Other: 4fr' TOTAL PLUMBING FIXTURES: Page 2 of 5 1.4 JUL : 7 0 2019 CiTy To Be Completed By the Applicant �rA�ACoR� rEs Project Address: 11 Pla-‘5 k cC ) n 0.coi +es 2- 1 Project Applicant: Ws1-ey Sck C , C hertis I &e .. k Applicant Email:Gh ) ,1 "s To I(Ai( r1C .03 r Phone No.: 3reo - - 0 6 Site Owner Name: ,,. h Josiôr PV System Description: 1 ssio ri OS w 2 h ph C eEnt) ?), f Determine if your project is eligible for an over-the-counter Permit (Check Yes or No) Yes No 1, PV System is designed and proposed for a detached single-family house, duplex or townhome. 2. PV System is designed for rooftop of house in general compliance with applicable ' ' codes. 3. Mounting system is engineered and designed for PV. 171 4. Rooftop is made from light weight material such as shingles. o 5. PV system will be permitted and pre-approved by Labor & Industries Electrical G division. 6. To address uplift, panel are mounted no higher than 18" above the surface of the x. roofing to which they are affixed. Except for flat roofs, no portion of the system may exceed the highest point of the roof. 7. Total deal load of panels, supports, mountings, race ways, and all other i a` appurtenances weight no more than one of the following. IF Yes, indicate which: `� No more than three and one half(3.5 pounds per square foot (P5F) o Frameless panels on at least 3/12 pitch roof weighing no more than four and one-half (4.5) PSF o Frameless panels on at least 5/12 pitch roof weighing no more than five (5.0) PSF 8. Supports for solar panels are installed to spread the dead load across as many o roof-framing members as needed to ensure that no point loads in excess of fifty (50) pounds are created. 9. Attachment to the roof is specified by the mounting system manufacturer. I , I o 10. Panels are mounted no higher than the roof ridge or apex of roof(applies only to pitched roofs). Comments: o By Checking this box, I certify that all of the information provided on this form is correct. If you answered yes to all of the above questions, your PV installation is eligible for an over-the-counter building permit. To apply please bring in this completed form to our permit center at City Hall for an over-the-counter permit. To be Completed By Staff Project is eligible for over-the-counter permit? 0 Yes o No ��x o City of Anacortes Photovoltaic System Permit v_s 1 .w Submittal Requirements Permit Required: A building permit is required for the installation or replacement of solar/photovoltaic(PV) systems, including roof top arrays,ground-mounted arrays and PV water heaters. An electrical permit is required from the State Department of Labor& industries. Single family residence rooftop installations meeting the criteria in the attached checklist are eligible to obtain a building permit over-the-counter at the permit center in City Hall. CODES: International Residential Code (Current Edition) International Building Code (Current Edition) International Fire Code(Current Edition) National Electrical Code (Current Edition) FEES: Building Permits for installations are based on the material cost of the support system and labor for the installation. SUBMITTAL REQUIREMENTS FOR PV(OTHER THAN ONLINE OR OVER-THE-COUNTER PERMITS): 1) Permit Application Form A. 2) Site plan showing location of house and array/equipment on lot,with setback dimensions to property lines. 3) Roof plan showing the array. 4) Manufacturer specifications or the PV panels and mounting hardware. include the weight of the equipment. 5) For rooftop systems not conforming to all of the criteria in the attached checklist, provide a roof framing plan and either: a) Structural calculations by a WA State Licensed Engineer or other competent person showing the adequacy of the existing roof structure to support the additional load, or b) Documentation showing that the roof structure was substantially overbuilt compared to prescriptive code requirements. 6) For ground mounted systems provide structural calculations by a WA state licensed engineer or other competent person showing how the structure meets wind design requirements for the structure and footings. Note that ground mounted equipment greater than 36 inches in height must adhere to minimum required property line setbacks of the applicable zoning district. NOTE:The purpose of this handout is to assist the public in complying with detailed permit submittal requirements. It is NOT a complete list of permit or code requirements and should NOT be used as a substitute for applicable laws and regulations. It is the responsibility of the owner/design professional to review the submittal for completeness and applicability to other codes. Only complete applications will be accepted by the City for review. � n It. lr'' :CITY OF ANACORTES �. DPLAgNLNGgz, hL icy ` EPT, Oilf APPROVED PLAS PERMIT #: ftj 1 201 iL,) CTYOFANAC R-DES (22) Mission Solar MSE PERC 60, 305 Watt Photovoltaic Ivt64tl S: Total System Size: 6,710 Watts DC, 6.71 I<Ws . - Vmp=32.61 V, Imp=9.36 A, Voc=39.95 V, Isc=Apo ED 'BY: J �� Module Dimensions: 39.33" x 65.51" x 1.57" C RR e�,;firr ;�t `APR VED PLANS Prime Consultants Inc. Installed per Manufacturer Recommendatrt��� T TO FIELD I�,I E,.,ITO ,y. , dba. Western Solar Inc. on roof of residence using flushmount Snap NU LL , �T RE ALALTERED 1.''''T QUT AUT R6ZAT1(� '. �" 4041 Home Rd Ste A i3eilinailham WA 98226 Mounting System installed at 48" on center, + ' l t ,i .� : into premanufactured trusses at 24" o.c. ' 1 ! ! ' ,• 1 t t i , , !1 .1 �1i i I� t3i9ESTEs 910J® } 'l l 1 1. § 1I` k4.1 ,+ %j , +! ' ..\;\';\ i i ` 1 li 1i i0;\ i �,1 , + ,?kt ' 1t Meets all City of Anacortes Structural Permitting Requirements ; \ t i ; \1111 \t.+t , � , t ;� � k l !� `� ,1;tt,t�;1'; L�rojectManager: 40.1 lbsper solar module x 22 modules = 882.2 lbs , i l ; , , ; 1 i i 1 t ,t ! , � , � il k . ; , 1 i11 Vt' \\ '�`+ Eric8lai�z 17.89 s fit er solar module x 22 modules = 393.58 s ft ' , i1i i , \1\ \ , +q p q i Hil ; i t , l I t , 4 ➢4 . Home Rd Ste A • 882.2 lbs / 393.58 sqft = 2.24 lbs/sqft. ! I, i i t i,11 +V iY1\ i j 11 ` 1 {, �+ q I 1 ` i �1� ti 11 ,` Beigin� harp WA 98226 Notes: 1 1 kit 1 \ ! \ ° i+, t k \`\,� Tel: 360-224-9839 Exterior/Interior DC Conduit Runs i It k I I + l ,\ t•.\+ \t 1 to be labeled as: t i i i ' 1 : t 1 y `� t,., 1 i ' ' `, - - iT iT (� 4-. , ' , II ' 1 . ,11., 1 1 `'t t\ 1� Installing Electrician: Photovoltaic Conductors , i I ` 1 1, 15 degree comp ; >i 1 1 ;\ I , ti` \ t 1 Prime Consultants Inc. Main Disconnect to be Identified as: s 1 1 ! ' t I \ t \, t l , '! , t i t` dba. Western Solar Hnc. "Photovoltaic Power Source" --- 1 {I 1 i 4 t \ t It ' ;It\`; i+1\ t , \\\ 4041 Home Rd Ste aJ; — - io: 1 t \� 1 i t , , Design meets requirements of: - -________... __ - -`_ 1 1. i t• \ i 1, , ��\ V� ' Bellnne�6�am, WA 9822 WAC 51-54A-0605 _ __. ----T- - -_ _ yi ' !1 \ �i� y\ ,� '\t„3,\,_` y �-__ - LEC : WEs-rEs872r�D 605.11.1.1, 605.11.1.2 �- - - - __�._—___ -�_ `,\ i i i+1 `=---- Section __ _ -- �- -___. -_ i- w. _�- _-___-� •` '�- -_ - Client Name: :cr _ � _.-_= _` _ = _-= - _ _ _._- �_�- _____ -____ — John. John Janson -- ... :--____-_ - -- - -- _ 4907 Paisley P� _ _ :-_-___=_._._.� - .. .:-_- _-- --- - - _ __ -_ Anacortes, WA 98221 4. rf ---- ` Sales/Designver: ---- wash MEMe-- — - - _Issue Date: --- - - -. — 7/9/19 W E s ) :11 1 , f$1. t I JUL 10 2019 Notes: Exterior/iiroterior DC Conduit R ➢rus I ' e� - � R� to be Qal} Q d C TTptaotovoit is Conductors, _ Main Discornalect to be tdernti ied as: "Photovoltaic Power Source" 1 nl r �- fptriar➢ R➢vaadtaF➢tsuac. psi rro meets requirements : j f ba. Western Scalar Inc. 'MAC 5"�.i-54A-0605 Section 605.11. '�. , 605,1�s L / ��� 4041 Bellingham,e Rd Ste A Total PV Array Area: 393.58 sqft / l ` Total Roof Area: 2,057 sqft r. .•, 0/0 Roof Area of Array: 1 % \ �. ✓/ , I Project Manager: 33% Rule Applies �, - ' 1 Cris f dafc PV System ir�MtadGe with "" setback�> _1 -- , I a1 Home Rd Ste A from ridgesBeddiotghaara, rA $2Zfr r I Teti: 360-224-9839 s n ,II' ' ,`� �I 1 installing Electrician: 17/1411:i g1PA a r!a l' Prime -Cor sE1nitarts RUC. s i a 11 dha Western Solar a➢ . i" k 'i ' 404Y;. Home Rd Ste A If i Gg, Bellingham,am, WA 98226 Ittyli gib li t -! L� #. Fo1f� G[ES 8v < i7 �'TgfrVA Y<14; • r j I� PV Syst n Es Wall Jn ➢ Janson.,� �u ,` aL °' setback f o Residence lee,➢ 4,007 Paisley Q from ridgeva _ :I i 1 : I An➢ I r�rtes, �1 Parcel # G5990i i ,7 I Project Size: � i�ia➢ Roof SFR: N 2,057sf 32' �. k<'r llF t System L Eis Proposed PV Solar Array: 393.58 sfi` in SaQeyf Q esi raer: rVl Josb Miller / '. Issue Date: G 7/9/19 n,u ' A '1111( ` � d Site ,Plan �1 i r D {g 1p 0 \vi 911 -- 1 JUL 10 2019 NOTES: REVISION F ANACOBTE - 5/16"LAG BOLTS MUST EMBED 2,5" INTO ROOF STRUCTURAL MEMBERS/CITYRAFTERSO STEP 3: PLACE L FOOT TORQUE ALL S/16"HARDWARE TO ON TOP OF FLASHING SNAPNRACK THE FOLLOWING: AND TIGHTEN NUT COMPOSITION L FOOT -SILVER S.S. 10-16 FT-LBS CAN BE MOUNTED IN S. FLANGE NUT -BLACK S.S.7-9 FT-LBS STEP 2:SLIP FLASHING OVER ANY ORIENTATION I4 - RAILS CAN MOUNT TO EITHER SIDE L FOOT BASE AND UNDER ROW 1;X 1"(OR 1,25") OF L FOOT(UPSLOPE VS DOWNSLOPEJ OF SHINGLES ABOVE SNAPNRACK S.S. BOLT AND 4 ; CHANNEL NUT `. SPLIT WASHER 1 tt, r S.S. LAG SCREW WITH FLAT WASHER SNAPNRACK 2,5" MINIMUM EMBEDMENT STANDARD RAIL IS STANDARD � - SNAPNRACK COMPOSITION ROOF FLASHING ` STEP 1: BOLT L FOOT yr. BASE TO ROOF WITH :. t;„ LAG BOLT ;al SNAPNRACK L FOOT BASE ROOF DECKING TYP. 0cl, ROOF DECKING TYP. FLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF SURFACES WITH LOW TO MODERATE TILT RAILS CAN BE LEVELED UP TO 3"USING 4. UP TO TWO LEVELING SPACERS AS SHOWN IN"SERIES 100 RAIL LEVELING" COMPLETED INSTALLATION RAFTER:1YP. �j MAINSTREAM ENERGY CORP, DESIGNER: G McPI,eeters SCALE^ DNS PART NUMBER^ DESCRIPTION, REV WC ( CC C�i n "M DRRt TER, D Ryan SI00 PEN Dot PEN DETAIL 01,FLASHED L FOOT TO C V iN P9 !`IPA R d F WV G ilc�tuntbotal Systems Hw_ Wr,u ' " APPF$OvED SY: DATE` 120113 RAFTER