Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File BLD-2019-0340 511 4th Street
rgNIICVNI- ... Isy 30 2019 -st - CITY OF ANACORTES ,`;R " j" fl `` y4 1111 �p ' CITY OF ANACORTES PLANNING & BUILDING DEPT: qr�tcj.,.• _s PLAN R to PERMITTh �� UNDERWOOD 3 &ASSOCIATES,LLC ADDRESS: ST ^ pPp _ 1005 4th Street APPROVED QY: anacortes, Washington 98221 SUBJECT TO FIELD INSPECTION'. APPR VED PLANS 360.588.0471 Omalanz Shop SHALL NOT BE ALTERED WITHOUT AUTHORIZATION_ mike underwood,AIA — Commercial Ave mike@ underwoodarchitecture.com v m:. ,-. o 0 0 — x _ , < 4th Ave Project Site 4ftkz1 R Q r ecft O r k oh O p l".ti-. _ e r L"ti.� u © n z ,, . .2 Y' l y °• - 4 � r 2 e..p„ W '.'. ny .... = _ ' T ' Architectural Sheet List Site _ Sheet � 1" = 1'-o" Number Sheet Name A0.0 Title Sheet A3.1 Floor Plans This Is A Standard List Of Abbreviations Used By This Office. Items Grand total: 2 Listed May Or May Not Be Used On This Set Of Drawings. kb. Anchor Bolts /+ Ga. Gauge R. Riser AAc, Acoustical V Galv. Galvanized IN Rad., R Radius Add. Addition Glu-lam Glue Laminated R.d. Roof Drain Adj. Adjustable/Adjacent GLB Glue Lam Beam Ref. Reference A.f.f. Above Finished Floor Gr. Grade Reqd. Required Alt. Alternate GWB Gypsum Wallboard Rm. Room RO Rough Opening Bld. Building KB Hose Bib B Blk Block H HC Hollow Core 9 Registered B.O. By Owner Horiz. Horizontal SC Solid Core ARCHITECT 1 Btm. Bottom Hr. Hour S Sect. Section --43•-"----) B.U.C. Built Up Column Hdr. Header SF Square Feet Michael G. Underwood BWP Braced Wall Panel Shtg. Sheathing General Notes Building Code Energy Code Notes Project Directory Building Information State of Washington Insul. Insulation Sim. Similar CCab. Cabinet I Int. Interior Spec. Specification exp. 09/22/19 Cdr. Cedar Sq. Square 1. All potential contractors shall thoroughly Zoning Category: R3, Residential Medium Density District This building is governed by the 2015 WSEC, Prescriptive Energy Code,for Owner: Mike& Kathy Omalanz Site Address: 511 4th Street SS Stainless Steel Small Dwelling unit: Points 5114th Street Anacortes, WA 98221 C.j. Control Joint Jt. Joint familiarize themselves with job conditions beforep re I I m 1 n a ry Std. Standard Anacortes, WA 98221 Clkg. CaulkingJst. Joist bidding to ensure that they understand the scope of Permitted uses:Stl. Steel Ener Credit Requirements: 1.5 points C.L. Centerline Star. Storage the work. These notes are general in nature and are Single Family Dwelling units Energy Credits Prposed: 1.5 oints Parcel Number: P56781 CMU Concrete Masonry Unit K Kit. Kitchenintended to set the minimum standards for Architect: Underwood &Associates, LLC SS Storm Sewer Col. Column construction. Any conditions which are not clear or Permitted accessory uses: High Efficiency HVAC Equipment 3a:1.0 Energy Credits 1005 4th Street Legal Description: Project name: Lavatory Susp. Suspended L Lay. Conc. Concrete Y are different than required by code or site conditions Garage, tool house Anacortes,WA 98221 LOTS 6, 7, &8, BLOCK 5, BOWMAN'S CENTRAL SHIP HARBOR Constr. Construction Iv' Microlam timber Gas,propane or oil-fired furnace with minimum AFUE of Jeremy McNett, Assoc. AIA WATERFRONT PLAT OF ANACORTES, RECORDED IN VOLUME 2 OF 0 m a I a n z Shop Cont. Continuous Isl Timberstrand timber T. Tread shall be brought to the attention of the designer 94%,or Gas,propane or oiled-fired boiler with minimum Y verify (minimumzone): AFUE of 92/° 360 588 0471 PLATS PAGE 33, RECORDS OF SKAGIT COUNTY, WASHINGTON. TOF Top of Footing immediately. The contractor shall ver all Lot Size in ° D. Dryer Double Mat. Material TOC Top Of Curb dimensions and conditions on all sheet drawings 6,000 sf for Single-Family Renovation DDbl. T&G Tongue& Groove and in the field, and notify the designer of any Efficient Water Heating Category 5a:0.5 Energy Credits Building Areas: M Max. Maximum . Thk. Thick discrepancies before proceeding. Setbacks: residential bathroom lavitory sink faucet: gal/min Contractor McCool Construction Co. Existing Residence Area: 1,305 sf Df Douglas Fir M.b. Machine Bolt TOS Top Of Slab Front: 20 feet 310 Q Ave Existing Garage Area: 840 sf (no change) Dn. Down Mech. Mechanical TOW Top Of Wall 2. Specific notes and details shall takeprecedence Side: 5 feet minimum, 15 feet total Anacortes, WA 98221 Project: 2019-B DS Downspout Memb. Membrane p 1 Dtl, Detail Min. Minimum Tv Television over general notes and typical details. Rear: 20 feet Jerry McCool Site Area: 9,148 sf DW Dishwasher Washer Mir. Mirror Typ. Typical Where the rear yard abuts a platted alley, a Codes 360-299-8844 Issue Date: 4-30-19 Mtl. Metal U UNO Unless Noted Otherwise 3. Dimensions shall supersede scale, and are detached accessory structure, or that portion of the Lot Coverage by Building: no change Ea. Each measured from edge of stud. primary structure used as an accessory structure, may 1. building 2015 IRC Revisions E EL Elevation n New be built in a rear yard up to the alley property line, 2. mechanical 2015 IRC No. Date Description O Var. be P Elec. Electrical N NIC Not In Contract 4. All work shall conform to the latest approved provided that it is set back a minimum of three feet 3. plumbing: 2015 UPC Elev. Elevator V VCT Vinyl Composition Tile NTS Not To Scale editions of the standards listed in "codes". from any side property line, and is no larger than one 4, energy and ventilation: 2015 WSEC Vert. Vertical z EQ Equal Vest. Vestibule thousand square feet and no more than sixteen feet in Equip. Equipment OC On Center 5. Provide 6" high temporary and permanent height. i (e) Existing Exist. Existing o OFCI Owner Furnish/ Project Description Contractor Installed W. Washer site that are viewable from the ot Ext. Exterior W W/ address numbers on street, Allowable Height: 3 stones, 35 feet Opng. Opening WC Water Closet Relocate interior, non bearing stud walls, restroom FD Floor Drain OSB Oriented Strand Board WD Wood 6. Confirm location of all utilities within easements Parking: Two off-street parking spaces per dwelling unit. plumbing, and fixtures, and add wood framed floor NI W/O Without and on site prior to excavation work. on existingconcrete floor. F Fin. Finish p Tid F.f. Finished Floor P lam Plastic Laminate WP Water Proof T FS Finished Slab r Ply Plywood WWF Welded Wire Fabric PR Pair FLR Floor Fnd. Foundation PSL Parallam timber PT Pressure Treated F.o.c. Face Of Concrete Sheet F.o.s. Face Of Studs Title itle Sheet Ft. Foot Or Feet z Fur. Furring F.e. Fire Extinguisher 'i- Project Info ___/ 1/4" = 1'-0„ AO . 0 CJ 5/29 12:32:36 PM 7-21/2" 6'-0" 3'-4" r ii I splitcabinets clamp rack 1�4 dust collector J Shaper ` 0 Tenon Machine Illi i existingmini I I fire wood hard wood Al2 Compressor - UNDERWOOL drill &ASSOCIATES,[LC i_1 press o- new32"x80" p.2^ �� o - \ relocate(e)door, i �I� 1005 4th Street existing plumbing fixtures pocket door g connected to ss \ - infill and patch to _ anacortes, Washington 98221 1 _ - match adjacent wall sander 360.588.0471 _ _ - - � N >, HTR mike underwood, AIA f j I remove(e)partition a � ', c I o- 5 elwalls and door 03 a mike@underwoodarchitecture-com 2 P4 _ _ _ _ Plaer Table Saw HTR P. n1 Router table Floor Plan Notes: relocate(e)plumbing — 1. All dimensions are to face of 0- i- and fixtures 'crirelocated(e)door S stud unless noted otherwise. Machine Room Clean Room ea ea 2. All interior partitions are 2x4 - the existing concrete slab level here is 0 16" o.c. Studs unless noted approximately 8"lower than the adjoining , o- 6m a _ E a otherwise. a_ room floor level _ t4 new electric baseboard heater t 3. Provide backing in all bathrooms - j _ for towel bars, toilet dispensers, table saw I with medicine owner for locations. Coordinate 1 o- o � m r N E o- a 0 HTR N = I g- g -5 CD a a- t N BS g 1 E 1 F existing overhead door to remain 1,1 existing door to remain I 10'Garage Door - French Doors j I �-Th Existing Floor Plan Demo Plan �3� Floor Plan 1/4" = 1'-0" -J I I I 9878 Registered ARCHITECT I i Michael G. Underwood i j I State of Washington 1 ` // new walls shown exp. 09/22/19 - �yDvld inf^ rl�� vv�l��iry for reference - J� - m di eal i preliminary 11 11- Project name: Floor Framing Notes: Layout shown here is for schematic II - _ _ _ _ - - l Omalanz Shop design only. Manufacturer shall provide II _ and submit engineered design to the I - - - - — ,; - - - - 1 Renovation building department for approval prior I 0 / to fabrication and installation, i Note:Finish floor to match height II @5 1 of adjacent"Clean Room"floor y - Floor sheathing: o I Project: 2019-B 1. Use 3/4" cdx or OSB Sturdi-floor I -A Issue Date: 4-30-19 T&G, glue and nail w/ ring shank 8d's at < at owners option,provide rigid 6" at edges and 12" in the field. Face ! - - , H insulation board between joist bays Revisions grain perpendicular to supports. II 2. Connections: Simpson Cmpy. or eq. No. Date Description c use galvanized fasteners when in c) 3. Provide full height blocking between I' II contact with p.t.material T joists at overlaps to prevent %-?- �I overturning. < l provide felt isolator between concrete masts -- - - - - - - -1 and p.t.joists Fasteners: � 5� - las. i N Metal elements, including connectors, `vim " - — _ , must use hot-dipped galvanized metal I co when in contact with ACZA pressure ' OP i k ,6 treated materials. [r319.3] - see 37/sp1 %Sii " _ _ _ - ffi h 1- - I I E 3/4"T&G plywood-glue&nail o to supporting members Floor Plans (4m, Floor Framing Plan - v ' N A3 . 1 c., 5/29/2019 12:32:37 PM 'LP --200—071/0 c. y rr_A ING, COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT r al ESIDENTIAL BUILDING PERMIT APPLICATION 7 ' �, Mailing Address:P.O. Box 547, Anacortes, WA 98221 teal Y 33 2019 Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 CITY OF ANACORTfig PLEASE REFER TO THE RESIDENTIAL BUILDING PERMIT CHECKLIST BELOW FOR SUBMITTAL REQUIREMENTS PROJECT ADDRESS(Street,Suite#): PARCEL(S)#: 511 4th Street, Anacortes, WA 98221 P56781 Subdivision/Lot#: PROJECT VALUATION: $ $10,000.00 APPLICANT: Phone: Mike Omalanz Address(Street,City,State,Zip): Email Address: 511 4th Street, Anacortes, WA 98221 PROPERTY OWNER: Phone: Mike Omalanz Address(Street,City,State,Zip): Email Address: 511 4th Street, Anacortes, WA 98221 CONTACT PERSON: Phone: Jeremy McNett 360-588-0471 Address(Street,City,State,Zip): Email Address: 1005 4th Street, Anacortes, WA 98221 jeremy@underwoodarchitecture.com LENDING AGENCY: Phone: Address(Street,City,State,Zip): Email Address: CONTRACTOR:* Phone: Jerry McCool 360-299-8844 Address(Street,City,State,Zip): Email Address: 310 Q Ave, Anacortes, WA 98221 mccoolcc@frontier.com Professional License#: Exp.Date: *All Contractors&Subcontractors must have a valid City of Anacortes business license prior to doing work iN the City. Contact Business License#: Exp.Date: the City's Finance Department at(360)299-1968. PROPOSED WORK: Relocate interior, non bearing stud walls, restroom plumbing, and fixtures, and add wood framed floor on existing concrete floor. PROPOSED NEW SQUARE FOOTAGE: Basement SQ': ❑ Finished Basement: ❑ Unfinished Basement IS`Floor SQ': Garage/Carport SQ': No change 2'Floor SQ': Deck/Covered Porch/Patio SQ': Fire Sprinkler: ❑ Yes ® No Lot Area SQ': I declare under penalty of perjury that the information I have provided on this form/application is true, correct,and complete,and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Anacortes. Print Name: d2/`eAN Owner ❑ gen (specify): �/c,� Signature: Date: S.- Z`f ( off Page 1 of 5 IMPERVIOUS SURFACE AREA: Existing Impervious SQ': New Impervious SQ': Total Disturbed Land/Soil SQ': Total Proposed: Cut: Fill: New hard surfaces(pervious&impervious) Land converted from native vegetation to lawn or landscaping SQ' Land converted from native vegetation to pasture SQ' MECHANICAL: Equipment Type: Appliance/Equipment Information(new and relocated): Total#: Furnace: Gas#: Elec#: BTU: Other#: Wall Heater: Gas#: Elec#: Other:#: Location(s): Gas Water Heater: #: Location(s): Heat Pump: Elec#: Other#: Air Conditioning: Elec#: Other#: Radiant/Hydronic Heating: Gas#: Elec#: Other:#: Location(s): Exhaust Fans: Bath#: 1 Laundry#: Other: 1 Range Hood: #: Location(s): Fireplace: Gas#: Elec#: Other:#: Location(s): Clothes Dryer&Duct: Gas#: Elec#: Other:#: Location(s): Stove/Range/Oven: Gas#: Elec#: Other:#: Location(s): Gas Piping/Outlet(s): #: Location(s): Boiler Gas#: Elec#: BTUs: Location(s): Other: #: Location(s): TOTAL MECHANICAL OUTLETS: PLUMBING FIXTURES: Fixture Type(new and relocated): Total#: Fixture Type(new and relocated): Total#: Water Closet(Toilet): 1 Refrigerator water supply(for water/ice dispenser): Kitchen Sink: Pressure Reduction Valve/Pressure Regulator: Utility Sink: Water Service Line: Tub: Water Piping: Hand Sink: 1 Clothes Washer: Shower: Electric Water Heater: Tank-less? Yes ❑ No ❑ Dishwasher: Backflow Prevention Device: Hose Bib: Other: TOTAL PLUMBING FIXTURES: 2 Page 2 of 5 ,.Gl 9,6 PLANNING, COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT RESIDENTIAL BUILDING PERMIT CHECKLIST 1 7,E , Mailing Address:P.O. Box 547, Anacortes, WA 98221 `•� R Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 Plans shall be of sufficient clarity to indicate the location,nature, and extent of the work proposed, and conform to the provisions of the adopted International Codes and City Ordinances. PERMIT TYPE: CD a C c AD O .. • SUBMITTAL REQUIREMENTS: �? 0 o q 0 M The number indicates the number of 2 7Q - O a n ~� copies for submittal (if applicable). cD CD o c A e. o' Q CD `C rt "1 d j Residential Building Permit Application 1 1 1 1 1 Site an (Drawn to Scale & Surveyed—if 2 applicable) 2 2 0 2 Building Plans (Drawn to Scale) 2 2 2 2 2 Reduced Site Plan(11"X 17") 2 2 0 1 1 Reduced Floor Plan(11"X 17") 2 2 2 2 1 Structural Calculations (if applicable) 2 2 2 2 2 Energy Code Compliance(shown on plans) ✓ I Stormwater Minimum Requirements 1-5 3 3 3 3 Landscape Plan 2 2 2 Grading Plan/Cut/Fill 2 2 2 Critical Areas Report (if applicable) 1 1 1 1 Creotechnical Report(if applicable) i 1 1 1 Plan Review Deposit(due upon submittal) I ✓ i/ 1/ 1 ,/ Page 3 of 5 NOTES: 1. Handouts and standard details may be found on the City's Planning, Community, &Economic Development website or can be obtained at city hall during normal business hours. 2. Plans, calculation, &reports prepared by state licensed architects or professional engineers must be stamped and signed by the design professional. 3. The drainage analysis/plan&TESC Plan shall comply with the 2012 Department of Ecology's Stormwater Management Manual for Western Washington(as amended in December 2014). 4. For new single-family residential building permit applications, a non-refundable plan review deposit of$200.00 is required at time of application submittal per AMC 19.14.035&IRC 108.1.1. 5. For remodels/alterations for existing single-family residences, a plan review fee of 65%of the permit's valuation is required at time of application submittal per AMC 19.14.035 &IRC R108.2.4(1). 6. Within 180-days of application submittal refunds are allowed up to maximum of 80%of plan review fee so long as no review has been performed by staff per AMC 19.14.035 & IRC R108.5. The applicant must initiate this refund request by submitting a signed letter to the Building Department. Page 4 of 5 STAFF DETERMINATION OF COMPLETENESS: Please note,that the subject building permit application will be reviewed by staff for completeness. All of the items above as listed in the"Residential Building Permit Checklist"need to be submitted at time of application submittal unless deemed unnecessary by staff. If staff deems the application incomplete,the applicant will be notified by mail and/or email as to what items and/or revisions are still needed. Additionally,if the application is deemed incomplete,the applicant will have 90-days to submit the requested information per AMC 19.20.130(B)(2)(b). If the requested items and/or revisions are not provided by the deadline [90-days],the application may be rejected by staff and returned to the applicant along with any unspent application fees per AMC 19.20.130(C)(3)(b). FOR STAFF USE ONLY—COMPLETENESS DETERMINATION: IS THE APPLICATION COMPLETE? (CIRCLE ONE) COMPLETE INCOMPLETE If deemed incomplete,what is the date it was deemed incomplete? If deemed incomplete,was it deemed as such at the counter, by letter, or email (Circle One)? If by letter or email,when was it mailed by USPS or emailed? If deemed incomplete at the counter,when was this checklist with items circled given to the applicant? If deemed incomplete,what is the 90-day deadline for resubmittal of requested items and/or revisions? If deemed incomplete,who deemed it as such? _ (Please include the letter/email in the file detailing what additional items or revisions are still needed). If the application is deemed complete,what is the date it was deemed complete & who deemed it as such? Page 5 of 5