Loading...
HomeMy WebLinkAboutPermit File 4402 E Avenue N Y O A. W 414100111r OO , CERTIFICATE OF OCCUPANCY This is to certify that the below listed building or structure has been inspected and occupancy is hereby authorized: Description: New Single Family Residence Location: 4402 E Ave. Owner: Thomas & Geri Pack Constructed by: Anacortes Construction S_r vices. Building Permit #: BLD-2018-0128 Date issued: 03/13/2018 Use Zone: R1 Dated: June 12 2019 Authorizing Official: rEnergy Code wAsHfN( 'oN SINE U► :1\11611 Y EXTENSION ENERGY PROGRAM Support Residential Building Air Leakage Test (Blower Door Test) Results Permit #: I - J 4a/ ti o / Z g House address or lot number: 4447,- 6• Ave City: A (JV411b Zip: r 13 WA Cond. Floor Area (ft2): �1-1 Age of house: Source (circle one): P a 1 Ins _- Estimated Measured Results shall be reported as Air Changes per Hour at 50 Pascals (ACH50) and shall be calculated as follows: ACH50 = (CFM50 x 60)/ Volume Where: CFM50 = Blower door fan flow at 50 Pascal pressure difference Volume = Conditioned Floor Area of the housing unit x ceiling height Blower Door Test Result: . 10 ACH5Q ((� 3� CFM@50Pa Ring (circle one if applicable): Open6.2) B C Blower Door Fan Location: 6r-truk Weather Conditions: / o L- I certify that these blower door results are accurate and determined using standard industry protocol. e) Pc Company Name: Technician: - �C ( it•-iVe-41,11 Technician Signature: ate: Phone Number:f(�1(J p1341. 0741t 2015 Washington State Energy Code reference: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Once visual inspection has confirmed sealing (see Table R402.4.1.1), operable windows and doors manufactured by small business shall be permitted to be sealed off at the frame prior to the test. INSTALLED INSULATION CERTIFICATE P.O Box 2921 -4.1111111111416-,00 Office: (360) 424-5179 Mt. Vernon WA Fax: (360) 428-5081 MASTER INSULATION & SERVICES LL.0 We certify that the following residence has been insulated with the following materials: Flat Ceiling Batts VALUE R-49 Slope Ceiling Batts VALUE R-38 Exterior Walls VALUE R-21 Garage Ceiling Underheat VALUE R-38 Crawl Space VALUE R-38 Address: 4402 E Ave, Anacortes WA Certify by : Seirgio- Lo-zauo- Date Installed October 2018 Title Manager