Loading...
HomeMy WebLinkAboutPermit File BLD-2019-0115 (2) 1905 10th Street 13 L - 20 1 9 - OH s--- PLANNING,COMMUNITY,&ECONOMIC DEVELOPMENT DEPARTMENT .A1 V e„) 1,.., RESIDENTIAL BUILDING PERMIT APPLICATION Mailing Address:P.O. Box 547,Anacortes, WA 98221 1:7 Vallk1:7 Office Location: 904 6th Street,Anacortes WA 98821 --,1COCt- Phone: (360)293-1901, Fax: (360)293-1938 PLEASE REFER TO THE RESIDENTIAL BUILDING PERMIT CHECKLIST BELOW FOR SUBMITTAL REQUIREMENTS PROJECT ADDRESS(Street,Suite#): Parcel(s)#: 1905 10th St. P56070 Subdivision/Lot it: Project Valuation: $5 475 i APPLICANT:Cheryl Beadle Phone:360-746-0859 Fax: ... Address(Street.City,State,Zip): E-Mail Address: 4041 Home Rd.,Suite A,B'ham,WA 98226 cheryl@westernsolarinc.com PROPERTY OWNER: Carolyn Barney & Lyndon Greene Phone:360-299-9075 Fax: Address(Street,City,State,Zip): E-Mail Address:barneycl@msn.com 1905 10th St Anacortes,WA 98221 CONTACT PERSON:Cheryl Beadle Phone:360-746-0859 Fax: Address(Street,City,State,Zip): 4041 Home Rd.,Suite A,Wham,WA 98226 E-Mail Address:cheryl@westernsolarinc.com LENDING AGENCY: Phone: Fax: Address(Street,City,State,Zip): E-Mail Address: CONTRACTOR:* Fax: Western Solar Inc. Phone:360-746-0859 Address(Street,City,State,Zip): E-Mail Address: 4041 Home Rd„Suite A,(nem,WA 98226 cheryl@westernsoiarinc.com Professional License#: *All Contractors&Subcontractors must have a valid City of Anacortes CC WESTES*910J 0 Exp.Date:4/25/20 business license prior to doing work in the City. Contact the City's Business License g: Exp.Date: Finance Department at(360)299-1968. 602258981 12/31/19 PROPOSED WORK: Install Solar PV System PROPOSED NEW SQUARE FOOTAGE: Basement SQ': Finished Basement: 0 Unfinished Basement 0 la Floor SQ': Garage/Carport SQ': 2nd Floor SQ': Deck/Covered Porch/Patio SQ': Fire Sprinkler: Yes 0 No a Lot Area SQ': Is construction associated with an accessory dwelling unit? Yes El No a I declare under penalty of perjury that the information I have provided on this form/application is true,correct,and complete,and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Anacortes. Print Name: Cheryl Beadle Owner 0 Agent II(specify): Western Solar Signature: . .---- Date: 2/27/19 Page 1 of 3 IMPERVIOUS SURFACE AREA Existing Impervious SQ': New Impervious SQ': Total Disturbed Land/Soil SQ': Total Proposed: Cut: Fill: New surfaces(pervious&impervious) • Land converted from native vegetation to lawn or landscaping SQ': Land converted from native vegetation to pasture SQ': MECHANICAL: Equipment Type: Appliance/Equipment Information (new and relocated): Total#: Furnace: Gas#: Elec#: Other#: Gas Water Heater: #: Location(s): Heat Pump: Elec#: Other#: Air Conditioning: Elec#: Other#: Boiler: Gas#: Elec it: Other#: BTUs: Exhaust Fans: Bath#: Laundry#: Other: Range Hood: #: Location(s): Fireplace: Gas#: Elec#: Other:#: Location(s): Clothes Dryer:/Duct: Gas#: Elec#: Other:#: Location(s): Stove/Range/Oven: Gas#: Elec#: Other:#: Location(s): Range Hood: Location(s): Gas Outlet(s): #: Location(s): Other: #: Location(s): TOTAL PLUMBING FIXTURES: Fixture Type(new and relocated): Total#: Fixture Type(new and relocated): Total#: Water Closet(Toilet): Refrigerator water supply(for water/ice dispenser): Kitchen Sink: Pressure Reduction Valve/Pressure Regulator: Utility Sink: Water Service Line: Tub: Water Piping: Hand Sink: I Clothes Washer: Shower: Electric Water Heater: Tank-less? Yes 0 No 0 Dishwasher: Backflow Prevention Device: Hose Bib: TOTAL OUTLETS: TOTAL OUTLETS: Page 2 of 3 r} 0 PLANNING, COMMUNITY, & ECONOMIC DEVELOPMENT DEPARTMENT I ; RESIDENTIAL BUILDING PERMIT CHECKLIST Mailing Addre ss: P.O. Box 547, Arnacortes, If`A98221 ;._ �, �` Office Location: 904 6"Street,Anacortes YI"�1 98821 ' Phone: (360) 293-1901. Fax: (360) 293-1938 Plans shall be of sufficient clarity to indicate the location,nature,and extent of the work proposed.and conform to the provisions of the adopted International Codes and Cite Ordinances. PERMIT TYPE; .-. . SUBMITTAL REQUIREMENTS: a CI:- Q• cn. °t 0'.. r �. The number indicates the number of ; az 'I — n copies for submittal(if applicable). 7 O Q O ra = �' ot ram+ ;C tf n Residential Building Permit Application 1 1 1 1 1 Site Plan (Drawn to Scale & Surveyed— 2 7 0 2 2 if applicable) Building Plans (Drawn to Scale) 2 2 2 2 2 Reduced Site Plan (1 I"X 17") 2 2 0 1 I Reduced Floor Plan(I I"X 17") 2 2 2 2 1 Structural Calculations (if applicable) 2 2 2 2 2 Energy Code Compliance(shown on plans) Complete Stormwater Plan 2 2 0 2 13 Elements SWPPP Checklist 2 2 0 2 Landscape Plan 2 2 2 Grading Plan/Cut/Fill 2 2 2 Critical Areas Report (if applicable) 1 1 I 1 Geotechnical Report(if applicable) 1 1 1 1 Plan Review Deposit(due upon ✓ submittal) 1. Handouts and Standard Details may be found on the City's website at wv-w.citvofanacortes.om or can be obtained at City Hall during normal business hours. 2. Plans/calculation/reports prepared by state licensed architects or professional engineers must be stamped and signed by the design professional. 3. For details on the Complete Stormwater plan,please see the Residential Stormwater Application Checklist. Page 3 of 3 To Be Completed By the Applicant Project Address: 19 O t crth st , Project Applicant: Nes+ern .S 6 )04 ' -- - '. e 1 1a. Applicant Email:Cher (. S3f-eY ceclekiri (IC• CO NN Phone No.: :. ( - (cp- I Site Owner Name: C SIT 113 r 1 ' Ari oG---reervQ PV System Description: 5 1 4e ("11 ,ter rv4 I L \J 4 5) ,en phcx.seE e i t Determine if your project is eligible for an over-the-counter Permit (Check Yes or No) Yes No 1. PV System is designed and proposed for a detached single-family house, duplex or G townhome. 2. PV System is designed for rooftop of house in general compliance with applicable ? r codes. 3. Mounting system is engineered and designed for PV. 4. Rooftop is made from light weight material such as shingles. o 5. PV system will be permitted and pre-approved by Labor & Industries Electrical division. 6. To address uplift, panel are mounted no higher than 18" above the surface of the yJ p roofing to which they are affixed. Except for flat roofs, no portion of the system may exceed the highest point of the roof. 7. Total deal load of panels, supports, mountings, race ways, and all other appurtenances weight no more than one of the following. IF Yes, indicate which: No more than three and one half (3.5 pounds per square foot (PSF) Frameless panels on at least 3/12 pitch roof weighing no more than four and one-half(4.5) PSF Frameless panels on at least 5/12 pitch roof weighing no more than five (5.0) PSF 8. Supports for solar panels are installed to spread the dead load across as many o roof-framing members as needed to ensure that no point loads in excess of fifty (50) pounds are created. 9. Attachment to the roof is specified by the mounting system manufacturer. o 10. Panels are mounted no higher than the roof ridge or apex of roof (applies only to z o pitched roofs). Comments: By Checking this box, I certify that all of the information provided on this form is correct. If you answered yes to all of the above questions, your PV installation is eligible for an over-the-counter building permit. To apply please bring in this completed form to our permit center at City Hall for an over-the-counter permit. To be Completed By Staff Project is eligible for over-the-counter permit? Yes o No %IT o City of Anacortes Photovoltaic System Permit e ,. 14,01 Submittal Requirements Permit Required: A building permit is required for the installation or replacement of solar/photovoltaic(PV) systems, including roof top arrays,ground-mounted arrays and PV water heaters. An electrical permit is required from the State Department of Labor& Industries. Single family residence rooftop installations meeting the criteria in the attached checklist are eligible to obtain a building permit over-the-counter at the permit center in City Hall. CODES: International Residential Code(Current Edition) International Building Code(Current Edition) International Fire Code(Current Edition) National Electrical Code(Current Edition) FEES: Building Permits for installations are based on the material cost of the support system and labor for the installation. SUBMITTAL REQUIREMENTS FOR PV(OTHER THAN ONLINE OR OVER-THE-COUNTER PERMITS): 1) Permit Application Form A. 2) Site plan showing location of house and array/equipment on lot,with setback dimensions to property lines. 3) Roof plan showing the array. 4) Manufacturer specifications or the PV panels and mounting hardware. Include the weight of the equipment. 5) For rooftop systems not conforming to all of the criteria in the attached checklist, provide a roof framing plan and either: a) Structural calculations by a WA State Licensed Engineer or other competent person showing the adequacy of the existing roof structure to support the additional load, or b) Documentation showing that the roof structure was substantially overbuilt compared to prescriptive code requirements. 6) For ground mounted systems provide structural calculations by a WA state licensed engineer or other competent person showing how the structure meets wind design requirements for the structure and footings. Note that ground mounted equipment greater than 36 inches in height must adhere to minimum required property line setbacks of the applicable zoning district. NOTE:The purpose of this handout is to assist the public in complying with detailed permit submittal requirements. It is NOT a complete list of permit or code requirements and should NOT be used as a substitute for applicable laws and regulations. It is the responsibility of the owner/design professional to review the submittal for completeness and applicability to other codes. Only complete applications will be accepted by the City for review. Notes: E;dteruor/i�ruteruor �C Conduit Runs mr, to be Uabe&ed as: "Photovoltaic Conductors" Main Duscou dnect to be entuv ued as: "Photovodtaoc Power Source" Prime Consultants :inc. [Design meets requirements of: dban Western Solar Enc. WAC Si!.-34.A-OS05 eawssagiswal Al", 4'04.2 Home Rd Ste A Section 6O5.2�q-��,1, 603.1e1.2 Bellingham, WA 98226 ,� LE : WESTl ES*9'1OJO Total PV Array Area: 279 sqft 94' Total Roof Area: tv 3156 sqft - W/Q Roe.,f Area of Array: 8.8 % • Pro ect 6 a��a�ero 33% Rule Applies Croc late 22' 404,1 Come Rd Ste A PV System a�,0e���ruth��VH�c RTES SellurugG�au�, WA 98226 from rod YY I 4, Tell: 360-224,9833 LNG & BUILDING DEPT: � ti= _ ;,; �� k p r I{ LrustaG�uuuc [�le�ctrocuao�o (� Prime Consultants �� c .. ram.. � ii i �!II _ \ \ __.�I i�'I� (l l ( l... # Western 1�. p � ;� \ ' Z ao , �es cer� Solar Enc. �� PLANS 18" setbacks _ : , r 'liil{ f' -; !-1 ,� , �� 4'r041 Dome Re Ste PERMIT #: LP" l 9_01�.c 1 `� i! { 1!''�; Sellungham, WA 8226 ,l /\\ , M CieW ESTS*872©D ADDRESS: Q S N` — _ f! <I, APPROVEDI �Y: 1( ,� 3 ' -m �11111111111mr _ �� ! 110' Client Name: _ -mm n w nim wi�_ -_ ii , ii ___ _ �1i0S 'Carolyn Loth LR���dec�� reeruc SUBJECT TO FIELD INSPECTION.ION. APPR VED PLANS , �,i .i , h St {i� i�L I. rua�or�es® ° J�f� 221 hALL NOT BE ALTERED ` -t-9 sIOUT AUTHORIZATION. 'ill K ! '1 Project Size: !, S.4.75 kW PV System JJl PV System W 1 Disconnect Sales/Designer: 6' 4 Cauluu McSherr y : 6, llssue Date: 10 2/4/L S Parcel # P56070 ___4 ,� Site Plan Existing Roof SFR: tv 3156 sf - III Proposed RV Solar Array: 279 sf "4% Hates Exterior/1!nterior DC Conduit Runs r— (15) LG NeONR 365 Photovoltaic Modules to be labeled as: ; Total System Size: 5,475 Watts DC, 5.475 kWs Photovoltaic Conductors" Vmp = 36.7V, Imp = 9.95A, Voc = 42.8V, Isc = 10.8A livJain Disconnect to be Edentified as: 1 Module Dimensions: 40" x 66.9" x 1.6" "Photovoltaic Power Source" 1 Installed per Manufacturer Recommendations Prime Consultants Enc. ®esidn meets requirements of: on roof of residence using flushmount Snap N Rack dba° vdUestern Solar Enc. AC. 52.-54 -06'0S 4042. Home Rd Ste A Mounting System installed at 48" on center, Section 6© -��;1°J, 605°2..2.°2 f slur harm, Utif'A 9822 into premanufactured trusses at 24" o.c. 2Ec.:i e tsuEST S*9-1230 1 Meets all City of Anacortes Structural Permitting Requirements 40.8 lbs per solar module x 15 modules = 612 lbs Project aria er: 18.6 sqft per solar module x 15 modules = 279 sqft uric later 612 lbs / 279 sqft = 2.19 lbs/sqft. Home Rd Ste Bellingham, WA 98226 'Tel: 36'0-224-9839 i 1 \ �' \ , i I I _ _ �� I Prime Consultants Enc. r : l, 1 - t9 ! dba° West ern Sols:r ��nc° i.' iJ� ll!1, !) fI �' ' '., lY1 . ` t},1� 1, I' 4® s.1, C-Oome Rd Ste w ► i 11 4 'I i?f I ! 'l'ill l f l' l l l i Cat e 1 �� l�S�iI�F' Sellinghami, WA 98226 lI ,I I : I , I , II i •itz ) 4 !l ; (7 11 ' ._« 1Z�~e1 l�' j' `; '\ LI:C4: ; ESTLES -872DD ,,,1 J. i-;_ _ -i _ ��_—� ; ' \I ,'{ „ i /fid,;' fl i,,,, j r f. . tee —. j ,l ,`1 ,;\, rr r,r/r t „IA.__s- .: :a=_3_-,r. -,,. _— .11_�_. . . ._.— , f 1� 'I�'' Client (Name: um nen: imo r. , , ; - I�l�d� -l��S! i t,.. Carolyn ru ara�eQ� , Lyndon Greene HIM ,, -- - — — , - _ ` Anacortes, V6A 93222. r j C- - - II�11 ; , - - fl _ --- I I�r ++', - -- —� 1 'I Project Size: r ,1 ',,,l i:'f' 11 I } � i 11 , E. 3. ,75 iLs PV System /Ifi! 1 r41 o`4. r I I ! I I �° rrr:rrw i , j •�••• w• Sales/Designer: Callum lvdcSherru9 . , ;r��`''rr '*�r.. 26 degree comp 7�r w . tissue Dater: ` ' I - Extension site i `!f Vr f ( 2/1/ yl N _Al I oof ' ^�erdie '� IN E REVISION NOTES: - 5/16"LAG BOLTS MUST EMBED 2.5"INTO ROOF STRUCTURAL MEMBERS/RAFTERS STEP 3: PLACE L FOOT -TORQUE ALL 5/16"HARDWARE TO ON TOP OF FLASHING SNAPNRACK THE FOLLOWING: AND TIGHTEN NUT COMPOSITION L FOOT -SILVER S.S. 10.16 Fr-LBS CAN BE MOUNTED IN —BLACK S.S. 7-9 FT—LBS STEP 2:SLIP FLASHING OVER ANY ORIENTATION S.S. FLANGE NUT — RAILS CAN MOUNT TO EITHER SIDE OF L FOOT(UPSLOPE VS DOWNSLOPE; L FOOT AND UNDER ROW X]:`{OR 1.25") OF SHINGLES ABOVE. SNAPNRACK S.S. BOLT AND 411:, CHANNEL NUT SPLIT WASHER ti� r } r' 4"S,S, LAG SCREW WITH FLAT WASHER SNAPNRACK , . 2.5"MINIMUM EMBEDMENT STANDARD RAIL ^y ' IS STANDARD SNAPNRACK COMPOSITION ROOF FLASHING ,fir STEP 1: BOLT L FOOT BASE TO ROOF WITH LAG BOLT SNAPNRACK L FOOT BASE ROOF DECKING TYP. t�° ROOF DECKING TYP, FLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF SURFACES WITH LOW TO MODERATE TILT RAILS CAN BE LEVELED UP TO 3"USING UP TO TWO LEVELING SPACERS AS SHOWN IN"SERIES 100 RAIL LEVELING" COMPLEI:ED INSTALLATION RAFTER TYP. sn pr1 l� w MAINSTREAM ENERGY CORP, DESIGNER: G McPlieeters SCALE, DNS PART NUMBER DESCRIPTION: REV [k IUI'f111 �� ,- fi , ,*' '� DRAFTER to Ryan PEN DETAIL 01,FLASHED L FOOT TO I?M ilc mu t?6o� APPROVED9Y: DATE; 120113 S100 PEN D01 RAFTER