Loading...
HomeMy WebLinkAboutPermit File BLD-2018-0114 1213 24th Street 0 City of Anacortes Invoice/Permit#: BLD-2018-0114 904 6th Street Applieddate: 03/08/2018 Issue date: 03/08/2018 Cl� Anacortes, WA 98221-0547 (360) 293-1901 Expire date: 09/06/2019 Job Address: 1213 24TH ST Permit Type: Commercial Alteration/Repair Permit ANACORTES WA 98221-2592 Project: APN: P100698 P31917 P124175 P124176 P124177 Remarks: Tenant improvement for OB GYN clinic Owner: CHALLENGE DEVELOPMENTS II LLC Contractor: CREST CONSTRUCTION Address: 12062 MARINE DR Address: 17132 BENNETT RD ANACORTES WA 98221-8524 MOUNT VERNON WA 98273-9789 Phone: (360)293-7338 Phone: (360)424-8700 License#: CRESTCI927JG General Information: Fees: Building Valuation 200000 Plan Review Deposit 504.97 Construction Type ii-b Building Permit Fee 1,553.75 Occupancy Group bb Plan Review Fee 504.97 #of Heat Pumps 1 Mechanical Permit Fees 91.25 #OF AIR HANDLING UNITS <10000 4 Plumbing Permit Fee 104.00 #of Lavatories 8 State Building Code Fee 4.50 #of Slop Sinks 2 Total Calculated: 2,763.44 #of Ventilation Fans 2 Deposits/Receipts: 0.00 #of Water Closets 1 #of Water Piping 1 Total Due: 2,763.44 z .y. - r _n •- v 1 t ;,1 ,- !'{' I:.I 1 f'., -h r, rr �- t kit tu. I-.. M. (. CI 4.• p.J n Q r- F:i = o 2, r c� C7-. r• � J_ 0 i-i N• 07, tT et •• • - -4 rt I% CO „' r- r- THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, dikIF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMN, NCEP. kl HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL PntDVIS'PbI OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN ORPNOT_N GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER:JSTA1 o LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. '��r� J f_.1 it �: rJam' SIGNATURE OF•WNER OR AUTHORIZED AGENT ISSUED BY "" 4- -n 'I. Ingalls, Paul From: Peter Carletti <peter@carlettiarchitects.corn> Sent: Wednesday, March 07, 2018 1:25 PM To: Ingalls, Paul Cc: Mike McKenna; Mike Ruthford; Brian Ruthford Subject: RE: phone call Attachments: 18-201 IH OB GYN CITY.pdf Island Hospital will pay for the permit The contractor will pick it up and bring a check. I attached revised PDF's with the changes. Peter J. Carletti, LEED Principal CARLETT1 ARCHITECTS P. , VAP' AF„ --I TE TTurE,INTERIOR DESIGN,.&FL*NN:NG www.carlettiarchitects.com Ph: 360-424-0394 ext.101 From: Ingalls, Paul [mailto:pauli@cityofanacortes.org] Sent: Wednesday, March 07, 2018 1:05 PM To: 'Peter Carletti' Cc: Mike McKenna Subject: RE: phone call Peter, I have included the mechanical and plumbing elements, so it is now a combination permit.There are just a few plan review corrections. I believe all of them could be hand noted or corrected on the plans. Of course you could reprint if you want. 1. Cover page,A-0.0 has old code editions, 2012 IBC&2012 IPC, in several places. It should be 2015 IBC&2015 UPC (WA State did not adopt the IPC) 2. A-0.0.The Project Data notes: "Fire sprinklers existing modify as required" should be taken off the plans since there are no sprinklers in that part of the building. Same for the fire alarm note. 3. A-0.0.The accessibility generic notes and details should indicate that the center of the w.c. is from 16" minimum to 18" maximum from the adjacent wall with grab bar. Please provide a restroom detail drawing specific to this project 4. The north arrow is 180 degrees off on all pages except for A-0.0. Please correct. 1 No other issues have come to my attention. We can get it ready to issue; you can hand correct those few items before it is paid for and picked up. Who will be paying for the permit? Paul Ingalls Plans Examiner City of Anacortes (360)293-1908 From: Peter Carletti [mailto:peter@carlettiarchitects.com] Sent:Wednesday, March 07, 2018 7:54 AM To: Ingalls, Paul <pauli@cityofanacortes.org> Cc: Mike McKenna <mmckenna@islandhospital.org> Subject: phone call • Got your voice mail. Yes please include the mechanical and plumbing on this permit No this portion of the building is not sprinkled. It is part of the original FMA area. No this portion of the building does not have a fire alarm system. It is part of the original FMA area. Running out to a meeting if you need something else call me or email me. Do you know when you might be done with your review and ready to issue the permit? contractor is asking me. Thx Peter J. Carletti, LEED Principal CARLETil A, ARCHITECTS P.S. :HIT3t 'UR.3 TER3;OR CAE'7GP.&PIANNEN, www.carlettiarchitects.com Ph: 360-424-0394 ext.101 2 No other issues have come to my attention. We can get it ready to issue; you can hand correct those few items before it is paid for and picked up. Who will be paying for the permit? Paul Ingalls Plans Examiner City of Anacortes (360)293-1908 From: Peter Carletti Imailto:peter@carlettiarchitects.com] Sent: Wednesday, March 07, 2018 7:54 AM To: Ingalls, Paul <pauli@cityofanacortes.org> Cc: Mike McKenna <mmckenna@islandhospital.org> Subject: phone call Got your voice mail. Yes please include the mechanical and plumbing on this permit No this portion of the building is not sprinkled. It is part of the original FMA area. No this portion of the building does not have a fire alarm system. It is part of the original FMA area. Running out to a meeting if you need something else call me or email me. Do you know when you might be done with your review and ready to issue the permit? contractor is asking me. Thx Peter J. Carletti, SEED Principal CARLETTI ARCHITECTS p.a. otRCHITE-71.RE,INTE .3OR LIES3CA:&PL AMING www.carlettiarchitects.com Ph: 360-424-0394 ext.101 2 CITY OF ANACORTES BUILDING DEPARTMENT .y, 3 ✓w�. INSPECTION CARD (360) 293-1901 (Card to be on job site at all times) Job Address: 1213 24TH ST APN: P100698 Permit#: BLD-2018-0114 Issue date: 03/08/2018 P31917 P124175 1 P124176 P124177 Permit Type: Commercial Alteration/Repair Permit Expire date: 09/06/2019 Remarks: Tenant improvement for OB GYN clinic Applicant: Contractor: Owner: Lender: ISLAND HOSPITAL CREST CONSTRUCTION CHALLENGE DEVELOPMENTS II LLC 1211 24TH ST 17132 BENNETT RD 12062 MARINE DR ANACORTES, WA 98221-2562 MOUNT VERNON WA 98273-9789 ANACORTES WA 98221-8524 (360) 293- (360)424-8700 (360)293-7338 License#: CRESTCI927JG Inspection Date Inspector Inspection pate Inspector Inspection Date Inspector Initial Initial Initial Pik &;,- 44 fle-.,Ar g,/ •=7 1,a _ p(,,,,,/> 04-17:0 i,'%(-( 6;14,- ,r6t ic.<_________ s7 4 > , fl 1, 0 ? JA lut(e, ___ 0_ Lt L i; tf‘ CYCC'' COk0 ( Pi I'S° 31-°z ` t Y o� PLANNING, COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT RESUBMITTAL/ PLAN REVISION /ADDITIONAL INFO COVER SHEET ?s�tiw� Mailing Address: P.O. Box 547, Anacortes, WA 98221 \-�?co%� Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 299-1984, Fax: (360) 293-1938 Please use this form to submit revisions or additional information to your permit application. Permit/Project#: ,; d Date: leviProject Name: 1 s A 1 -1 , 2?? yII I<71Z, Project Address: I LI I Ilk 1`1r/g, C -j- Project Contact: 76 Company N me: l- V tk c;IS Contact Phone: 27f7O 424 O211�1 Contact Email: ? 1/G� CCivii b 14 i1 k4/ fl Has thepermit been issued yet? 0 Yes No All revisions must be eith r clouded gr` highlighted &wet stamped by an architect/engineer (if applicable). Has this been done? Yes 0 No What department(s) is this resubmittal/revision/additional information to go to? ,..014rlilanning Dept. 0 :uilding Dept. 0 ire Dept. 0 Stormwater 0 Public Works Dept. Is the plan revision or a•ditional information, in response to a plan review letter? 0 Yes. A copy of the plan review letter with itemized responses to each item is required. o,the revision or additional information is initiated by the applicant, landowner, designer, or builder. ,N If not in response to a Plan Review Letter, please explain the nature of the revisions and/or additional info: ry),\I 97 \(-6111-01S 1 i'l peAr mai( qivii canal.-641 44,01 ' ifilt7lin K/9141/14 Are you submitting a full replacement? Yes 0 No If not what page# is being replaced? 4i'4i1eui*i) X Two full sized copies of all revised/additional information is required. Has this been done? es 0 No Two 11"X 17" reduced copies of revised site or floor plan is required.Has this been done? Yes 0 No Check the box next to the type of plan, report, or calculation where revisions or additional information can be found. ❑ Site Plan I I . Building Plans 0 Structural Plan ❑ Landscape Plan 0 Parking Plan 0 Tree Preservation Plan ❑ Arborist Report 0 SEPA checklist 0 Wetland Report ❑ Geotechnical Report 0 Storm Drainage Analysis 0 TESC Plan ❑ Civil Plan 0 Lot Coverage Calculations 0 Impervious Surface Calculations ❑ FAR Calculations 0 Grading Plan 0 Survey(Boundary/Topo) ❑ Mechanical Plan 0 Plumbing Plan 0 Other: CERTIFICATE OF OCCUPANCY This is to certify that the occupancy listed below has been inspected and is hereby approved for use: Location: 1213 24th ST Description: Tennant Improvement for OB GYN clinic Owner: Challenge Developments II LLC Owner address: 12062 Marine DR, Anacortes, WA 98221 Building permit#: BLD-2018-0114 Date issued: March 8th, 2018 Constructed by: Crest Construction Edition: 2015 IBC Occupancy type: B Maximum occupancy load: 17 Type of construction: IIB Fire sprinklers installed? Yes Use Zone: R4B Square feet: 1700 Date: ,1/�f An Building Official: -,' Fire Marshal: Lighting Summary LTG-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1Revised Nov 2017 Project Info Project Title: Island Hospital OB GYN Remodel Date 1/1/2017 Compliance Applicant Information. Provide contact information for individual who can For Building Department Use forms do not respond to inquiries about compliance form information provided. require a Company Name: Island Hospital Primary Care Clinic password to use. Company Address: 1211 24th Street:, Anacortes, WA 98221 Instructional and calculating cells Applicant Name: AWA Electrical Consultants, Inc. are write- protected. Applicant Phone: 19015 36th Ave West, Suite E, Lynnwood WA 98036 Applicant Email: (4.25) 775-1799 Project Description ❑ New Building CI Addition '1 Alteration LJ No Lighting Scope Include PROJ-SUM form (included in envelope forms workbook) with lighting compliance forms. Interior Lighting System Remodeled area, no change to occupancy. Description DEB •sit% IInterior Lighting Plans Included Interior Lighting Power CI Building Area Method 2 Space-by-space Method Allowance Method_ Select method used in project. Interior Lighting Controls IA All C405.2.1 - C405.2.8 Lighting Controls Li C405.2 Exception 5 Luminaire Level Lighting Controls (LLLC) n Additional Efficiency Package Option C406.4 Enhanced Digital Lighting To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with required controls per C406.4. ',welling Unit Interior Permanently installed interior lighting fixtures in dwelling units comply with: No Dwelling { Units Lighting C405.2 thru C405.5 Commercial LightingControls and LPA C406.3 High Efficacy Lighting R404.1 Residential High Efficacy Lighting. Dwelling unit lighting complies with WSEC Residential provisions in lieu of WSEC Commercial provisions. Exterior Lighting System Description • Exterior Lighting Plans Included I.'nilding Additions Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable ® i� provisions as a stand alone new construction project Refer to Section C502.2.6 for additional requirements. Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance Addition is combined with existing: For interior lighting projects, include new + existing-to-remain interior lighting fixture wattage in Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. For exterior lighting projects, include new +existing-to-remain exterior lighting fixture wettage in Proposed Tradable and Proposed Non-Tradable Lighting Wattage tables in LTG-EXT form. Lighting Summary, cont. _ LTG-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Island Hospital OB GYN Remodel Date 1/1/2 017 'Change of Space Use 10I Existing interior lighting systems in areas under-going a change in space use are upgraded to I comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG-INT--BLD or LTG-iNT-SPACE form. Interior and Exterior Lighting Power Interior lighting ; Parking garage Exterior lighting L Lighting Alterations 50% or more of existing are replaced I D 0 Select all Lighting Pouter and Lighting Control elements that applyto the scope Less than 50% of existing are replaced Q 0 0 of the retrofit project. If project includes a - combination of spaces where less than Lamp and/or ballast replacement only a a 50%of the existing fixtures are replaced —existing total wattage not increased in some spaces, and 50% or more of the ° fixtures are replaced in others, then 50% or more replaced - Total lighting power of new+ existing-to-remain fixtures shall comply with provide separate lighting power total LPA per Sections C405.4.2 and C405.5.2. Include new+ existing-to-remain fixtures in compliance forms for the two retrofit Proposed Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. conditions. Spaces undergoing the same Less than 50% replaced - Total lighting power of new+ existing-to-remain fixtures shall not exceed type of retrofit maybe combined into one the total lighting power prior to alteration. Include new+ existing-to-remain fixtures in the Proposed lighting power compliance form. Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. 50% threshold applies to numberof luminaires for interior spaces and parking garages, and total Refer to Section C503.6 for additional installed wattage for exterior luminaires. requirements. , Lighting Controls Interior lighting : Parking garage ; Exterior lighting Al!alteration lighting controls shall be New wiring installed to serve added commissioned per C408.3. fixtures and/or fixtures relocated to ® a 13 new circuit(s) New or moved lighting panel o 0 a Interior space is reconfigured - luminaires unchanged or relocated New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application No changes are being made to specific lighting controls per C405.2.5. For exterior lighting,provide required controls per C405.2.7. the interior or exterior lighting New or moved panel- Provide all applicable lighting controls as noted for New Wiring and automatic systems and existing space time switch controls per C405.2.2. uses and configuration are not Reconfigured interior space - Provide all required lighting controls that apply to a new interior changed. space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured Interior Lighting - Space-By-Space Method LTG-INT-SPACE 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all F Revised Nov 2017 Project Title: Island Hospital OB GYN Remodel Date 1/1/2017 Calculation (� New Construction For Building Department Use Addition - 0 Addition Area NOTE 9 0 Spaces where < 50% of • Spaces where >_50% of 0 Spaces where the Use LPA . Standard 0 Additional Efficiency Package Option Calculation C406.3 Reduced Interior Lighting To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA.Type Refer to C406.3 for additional requirements. User Note Maximum Allowed Lighting WattageNOTE 1 Location (plan#, Ceiling Gross Interior Allowed Watts Allowed room#) Space Type HeightNOTE 2 Area in ft2 Watts per ft2 (watts/ft2 x area) Health care facility: Exam/treatment 926 1 .330 1232 Health care facility: Nurse station 465 0 . 570 265 Health care facility: Medical supplies 188 0 . 590 111 Restroom: facility for the visually impaired 50 0 . 970 49 Office: Enclosed 128 0 . 890 114 Total Area 1757 Retail Display Allowance from LTG-INT-DISPLAY Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAATE fi Allowed Watts 1770 Proposed Lighting WattageNOTE: Location (plan#, Number of Watts/ Watts room#) Fixture Description NOTE 4,5,6 Fixtures Fixture NOTE 7 Proposed F1 -2X2 LED TROFFER, 3400 LUMENS 23 26 598 F2 -2X4 LED TROFFER, 4500 LUMENS 10 33 330 F3 - 6" DIA. DOWNLIGHT, 1000 LUMENS 5 13 65 F4 - 2' LED VANITY LIGHT, 1500 LUMENS 1 40 40 F5 -4' UNDER CAB LIGHT, 2400 LUMENS 8 29 232 F6 - 3' UNDER CAB LIGHT,1800 LUMENS 10 21 210 F7 -4' LINEAR WRAPAROUND, 4424 LUMENS 1 44 44 Proposed Retail Display Lighting from LTG-INT-DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 1519 Interior Lighting Power Allowance COMPLIES Note 1 -List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category from drop down menu. Note 2 -Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 -List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. Note 4 -For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track(in feet) in addition to the fixture, lamp, and ballast information. Note 5-For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 -Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/bus way systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 -Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Enter all proposed lobby art/exhibit display fixtures in LTG-INT-DISPLAY form only. Note 9 -Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they maybe combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas. PLANNING,COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT t COMMERCIAL & MULTI-FAMULV BUILDING PERMIT APPLICATION Mailing Address:P.O. Box 547,Anacortes, WA 98221 Y4'` Office Location: 904 6th Street,Anacortes WA 98821 4c011-., Phone: (360) 293-1901, Fax: (360) 293-1938 PLEASE REFER TO THE COMMERCIAL&MULTI-FAMILY BUILDING PERMIT CHECKLIST FOR SUBMITTAL REQUIREMENTS PROTECT ADDRESS(Street,Suite#): Parcel(s)#: P116343 142,3 24th Street Anacortes, WA 98221 Landivision/Lot#: Project Valuation: $ 200,000 APPLICANT: Carletti Architects, P.S. Peter Carletti Phone: Fax: 360-424-0394 360-424-5726 Address(Street,City,State,Zip): E-Mail Address: 116 E. Fir Street, Suite A Mount Vernon, WA 98273 peter@carlettiarchitects.com PROPERTY OWNER: Phone: Fax: Island Hospital-Mike McKenna 360-299-1395 360-299-1344 Address(Street,City,State,Zip): E-Mail Address: 1211 24th Street Anacortes, WA 98221 mmckenna@islandhospital.org CONTACT PERSON: Phone: Fax: Carletti Architects, P.S. Peter Carletti 360-424-0394 360-424-5726 Address(Street,City,State,Zip): E-Mail Address: 16 E. Fir Street, Suite A Mount Vernon, WA 98273 peter(a7carlettiarchitects.com LENDING AGENCY: Phone: Fax: NA Address(Street,City,State,Zip): E-Mail Address: CONTRACTOR:* Phone: Fax: Crest Construction, Inc. 360-424-8700 360-424-1116 Address(Street,City State,Zip): E-Mail Address 17132 Bennett Road Mount Vernon, WA 98273 miker@crestconstruction.com Professional License# Exp.Date: *All Contractors&subcontractors must have a valid City of Anacortes 8CRESTC1927JG 05-31-2019 business license prior to doing work in the City.Contact the City's Business License#: Exp.Date: Finance Department at(360)299-1968. PROPOSED WORK: 1,854 s.f. tenant improvement within an existing building for an OB GYN clinic. PROPOSED NEW SQUARE FOOTAGE: Basement SQ': 1St Floor SQ': 1,854 s.f. existing 2nd Floor SQ': 3rd Floor SQ': 4tb Floor SQ': Garage SQ': Other SQ': Retaining Wall: Yes ❑ No N Fire Sprinkler: Yes ❑ No El Occupancy Group(s): B Occupant Load(s) Type of Construction: VB Existing I declare under penalty of perjury that the information I have provided on this form/application is true,correct,and complete,and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of A!- i . ' Print Name: `i / .. Owner ❑ A ent (specify): Signature: I Date: 2 16 I aoffloa /.9f4ji4 FEB 262018 1 6/0/1 ( -4 m�Gk , fr-e- IMPERVIOUS SURFACE AREA: Existing Impervious SQ': NA New Impervious SQ': Total Disturbed Land/Soil SQ': Total Proposed: Cut: Fill: New hard surfaces(pervious&impervious) Land converted from native vegetation to lawn or landscaping SQ': Land converted from native vegetation to pasture SQ': MECHANICAL: Equipment Type: Appliance/Equipment Information(new and relocated): Total#: Furnace: Gas#: Elec#: Other#: Wall Heater: Gas#: Elec#: 2 Other:#: Location(s):RESTROOM&DIRTY RM 2 Gas Water Heater: #: Location(s): Air Handler: Elec#: Other:#: 4 Location(s): VFR FAN COILS ABOVE CEILING 4 Air Conditioning: Elec#: Other#: 1 VFR HEAT PUMP,OUTDOOR UNIT,EAST SITE 1 Hydronic Heating: Gas#: Elec#: Other:#: Location(s): Exhaust Fans: Bath#: Laundry#: Kitchen#: Other#: Range Hood: #: Location(s): Fireplace: Gas#: Elec#: Other:#: Location(s): Clothes Dryer&Duct: Gas#: Elec#: Other:#: Location(s): Stove/Range/Oven: Gas#: Elec#: Other:#: Location(s): Refrigeration Unit: Elec#: Other:#: Location(s): Gas Piping: #: Location(s): Other: #: 1 Location(s): HEAT RECOVERY VENTILATOR,ABOVE CEILING 1 TOTAL OUTLETS: 8 PLUMBING FIXTURES: Fixture Type(new and relocated): Total#: Fixture Type(new and relocated): Total#: Water Closet(Toilet): removed 3 Refrigerator water supply(for water/ice dispenser): Kitchen Sink: Pressure Reduction Valve/Pressure Regulator: Utility Sink: Water Service Line: Tub: Water Piping: Hand Sink: removed 3 lays Clothes Washer: Shower: added 3 hand sinks Electric Water Heater: Tank-less? Yes ❑ No ❑ Dishwasher: Backflow Prevention Device: Urinal: Hose Bib: Floor Drain/Floor Sink: Drinking Fountain: Hydronic Heat in: Floor ❑ Wall ❑ Grease Interceptor: Refrigerator water supply(for water/ice dispenser): Other TOTAL OUTLETS: TOTAL OUTLETS: we are removing more plumbing fixtures than adding PLANNING, COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT -, °'" COMMERCIAL & MULTI-FAMILY BUILIING PERMIT CHECKLIST Mailing Address:P.O. Box 547, Anacortes, WA 98221 Office Location: 904 66 Street,Anacortes WA 98821 Phone: (360)293-1901, Fax: (360)293-1938 PI',EE-APPLICCATIONMEETING? YES ❑ NO X IfYes,Pre-application Number: Plans shall be of sufficient clarity to indicate the location,nature,and extent of the work proposed, and conform to the provisions of the adopted International Codes and City Ordinances. PERMIT TYPE: Ron)tt P = C SUBMITTAL REQUIREMENTS: i' a eo a cz o' tA ct C� T he number indicates the number of C4 41 c p copies for submittal(if applicable). B uo n X Commercial &Multi-Family Building Permit Application 1 1 1 1 X Site Plan(Drawn to Scale) 2 2 0 2 na Copy of Boundary Survey 2 2 0 2 x Building Plans (Drawn to Scale) 2 2 2 2 x Reduced Site Plan(11"X 17") 2 2 0 2 x Reduced Floor Plan(11"X 17") 2 2 2 2 na Structural Calculations(if applicable) 2 2 2 2 x Energy Code NREC Calculations&Lighting 1 1 1 1 na Complete Stormwater Plan&Drainage Analysis 2 2 0 2 na 13 Elements of SWPPP Checklist 2 2 0 2 na Landscape Plan 2 2 0 0 na Parking Plan 2 2 0 0 na Grading Plan/Cut/Fill 2 2 0 0 na Critical Areas Report(if applicable) 1 1 0 0 na Geotechnical Report(if applicable) 1 1 0 0 na Traffic Impact Analysis (if applicable) 1 1 0 1 na Plan Review Deposit ✓ I Digital Copy of Plans on Flash/CD (due at permit issuance) ✓ ✓ 1. Handouts and Standard Details may be found on the City's website at www.cityofanacortes.org or can be obtained at City Hall during normal business hours. 2. Plans, calculation, &reports prepared by state licensed architects or professional engineers must be stamped and signed by the design professional. 3. The Stormwater Plan&Drainage Analysis shall comply with the 2012 Department of Ecology's Stormwater Management Manual for Western Washington(as amended in December 2014). it � � GIN RAL NOTES DRAWI \ G INDEX0;=1 )'. 0 J E C Ir I = A M P R 0 J E C I D A I A 1. IN GENERAL PLAN DIMENSIONS SHOWN ARE TO FACE OF STUD OR FACE OF CONCRETE, UNLESS OTHERWISE NOTED. 00 NOT SCALE THESE OWNER PROPERTY INFORMATION DRAWINGS, USE CALCULATED DIMENSIONS ONLY. VERIFY ALL DIMENSIONS ARCHITECTURAL ISLAND HOSPITAL - ULTRASOUND/PAIN RECOVERY REMODEL DATUM AND LEVELS PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT ISLAND HOSPITAL IMMEDIATELY OF ANY DISCREPENCIES. A-0.0 COVER SHEET CAM.ETTI ARCHITECTS PoS. 1211 24TH STREET PROPERTY ADDRESS 1211 24T REST 2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO A-20 OVERALL FLOOR PLAN ANACORTES, WA 08221 ANAL S. WA 08221 INITIATING THE WORK. NOTIFY ARCHITECT OP ANT DISCREPANCIES. A-2-1 DEMOLITION FLOOR PLAN/PROPOSED FLOOR PLAN and to 1u a planning,into o design PHONE, 360-200-1305 A-2.2 DEMOLTION RELF. CEILING PLAN/PROPOSED REFLECTED CLG. PLAN EMAIL mmckannaelslandhospitaLorg BUILDING CODE 2015 IBC ® 3. ALL WORK SHALL COMPLY WITH THE 2015 IBC, IFC, UPC, IMC AS AMENDED BY WASH. A-29 SCHEDULES/INTERIOR ELEVATIONS 116 EAST FIR STREET CONTACT: MIKE McKENNA STATE. PROJECT SHALL ALSO COMPLY WITH THE 2016 NREC ANU THE VIACQ CODES. A-0.0 DETAILS SUITE A ENERGY CODE 2010 WASHINGTON STATE NREC PROJECT SHALL ALSO COMPLY W/ JURISDICTIONAL CODE AMENDMENTS BY THE LOCAL FIRE SPRINKLERS NONE EXISTING NOT REQUIRED AGENCY. CONTRACTOR IS RESPONSIBLE FOR OBTAINING NECESSARY PERMITS & MECHANICAL MOUNT VERNON, WA. 98273 ARCHITECT NONE TO COMPLETE THE WORK. CONTRACTOR TO HAVE CURRENT VALID CITY FIRE ALARM NONE EXISTING NOT REQUIRED OR COUNTY BUSINESS LICENSE PRIOR TO ISSUANCE OF PERMIT. WHEN REQUIRED BY LAW. M-1.0 COVER SHEET Phone: 360 424-0394 CARLETTI ARCHITECTS, P.S. M-1.1 SCHEDULES HVAC FOX: 360 424-5726 116 E. FIR ST. SUITE A 4. ERRORS, OMISSIONS. AND DISCREPANCIES, IF ANY. SHALL BE REFERRED M-1.2 SCHEDULES PLUMBING S PIPING _ _ __ _ _ MOUNT VERNON. WA 08279 ZONING R40 - IDE ITT TWO (B1 TO THE ARCHITECT IMMEDIATELY FOR DIRECTION OF HOW TO PROCEED. M-1.3 ENERGY CODE LOADS PHONE, 13001 424-0304 5. VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THE CONTRACT BY M-2.0 FLOOR PLAN PLUMBING/PIPING FAX: 1960) 424-5726 PARCEL NO.: P116349 OTHERS PROVIDE ALL BLOCK-OUTS, BLOCKING, BACKING AND JACKS REQUIRED FOR M-3.0 FLOOR PLAN HVAC EMAIL petorOcarlettiarchitocto.com DUCTS. PIPES. CONDUITS. EQUIPMENT. FIXTURES. AND CABINETS. VERIFY SIZE AND M-4.0 DETAILS ayy CONTACT. PETER CARLETTI I 6. LOCATION. DO NOT SIGNIFICANTLY VARY OR MODIFY THE WORK SHOWN. EXCEPT E STEREOU I BL ® I N G CODE DATA UPON WRITTEN INSTRUCTIONS OF THE ARCHITECT. ELECTRICAL ITECT MECHANICAL ENGINEER 7. VERIFY LOCATION OF ALL EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO: HARRIS GROUP. INC. SEWER. SEPTIC, WATER. GAS. POWER. AND TELEPHONE. CAP. MARK AND PROTECT. E-0.0 ELECTRICAL COVER SHEET. PANEL SCHEDULES HIM - 20201 CEDAR VALLEY RD. STE 120 OCCUPANCY TYPE, I-24 NO CHANGE 8. DETAILS ARE INTENDED TO SHOW THE INTENT OF THE DESIGN. MINOR MODIFICATION E-20 DE ELECTRICAL FLOOR L STATE r�r�stcmv LYNNWOOD. WA 98036 MAY BE REQUIRED TO SUIT THE FIELD DIMENSIONS OR CONDITIONS AND SUCH E-2.1 DEMMOO A AND PROPOSED L PLANS CONSTRUCTION TYPE, II-B, NO CHANGE MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK OF THE CONTRACT. E-22 DEMO AND PROPOSED POWER POWER PLANS PHONE: 206.404.0512 E-0.1 PARTIAL RISER DIAGRAM FAX. (4251 672-2084 REMODLED AREA SQUARE FOOTAGE, 488 S.F. 0. PROVIDE CLOSURE. MEETING THE REQUIREMENTS OP ALL GOVERNING EMAIL RIchard.Hawkinson@hatrisgroup.com AUTHORITIES, AT RATED PARTITIONS. FLOORS. CEILINGS, AND ROOF CONTACT: RICHARD HAWKINSON LOCATIONS. ALL REQUIRED FIRE-RATED PARTITIONS SHALL BE DEFERRED SUBMITTALS B V I A I IONS CONTINUOUS FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE. NONE ISLAND HOSPITAL ELECTRICAL ENGINEER 10. THE CONTRACTOR SHALL CONSULT PLANS OF ALL TRADES, INCLUDING PRIMARY CARE CLINIC AWA ELECTRICAL CONSULTANTS. INC. ABV ABOVE JNT JOINT DESIGN-BUILD DOCUMENTS REQUIRED BY CONTRACT DOCUMENTS, TO VERIFY EXPANSION AND IMPROVEMENT 10015 36TH AVE. WEST, SUITE E AFF ABOVE FINISH FLOOR SIZE, WEIGHT, POWER LOCATION AND OTHER REQUIREMENTS AND LOCATION LYNNWOOD. WA 0809E AC TILE ACOUSTICAL TILE LVL LEVEL OF THOSE ITEMS TO BE INSTALLED PRIOR TO COMMENCEMENT OF WORK. OB GYN CLINIC PHONE: 1425) 775-1700 ACP ACOUSTICAL CEILING PANEL L LONG. LINE 11. NO BUILDING OR PORTION OF A BUILDING SHALL BE OCCUPIED OR USED FAX, 1425) 774-0870 ACT ACTUAL LAV LAVATORY FOR STORAGE PRIOR TO THE ISSUANCE OF THE CERTIFICATE GWB, PAINT -"'> EMAIL laradOcrwaeloc.com OF OCCUPANCY. NO EXCEPTIONS. AL ALUMINUM LIN LINOLEUM ,..,..,-----&‘-'-` ISLAND CONTACT. BRAD ADCOCK 90 ( 48 MIRROR 18' VERT. HOSPITAL ARCH ARCHITECTURAL LT LIGHT 12. SEPERATE PERMITS ARE REQUIRED FOR PLUMBING. MECH.. ELEC, FIRE SPRINKLER WWI F.0 C. GRAB BAR A TILE ASPHALT TILE FIRE ALARM SYSTEMS & SIGNAGE. F.C.I.C. PAPER TOWEL GWB. PAINT CONTACT: AVG AVERAGE MAR MARBLE 13. ALL EXPOSED EXTERIOR SHEET METAL SHALL BE GALVANIZED, PRIMED AND PAINTED. DISP. F.O.TO. MO MASONRY OPENING � 1 1//2'GRAB BAR MIKE MCKENNA BFF BOTTOM F]NISH FLOOR MFR MANUFACTURE 14. ALL WOOD IN CONTACT W/ CONCRETE SHALL BE PRESSURE TREATED. SOAP DISP. 1,111111 P.C.LC. PRESSURE TREATED WOOD SHALL BE USED FOR WOOD MEMBERS WHICH ki F.O.LO- BLKG BLOCKING MAIL MATERIAL FORM THE STRUCTURAL SUPPORT OF BALCONIES, DECKS, OR PORCHES , TILE 72' AF.F. BR BRICK MAX MAXIMUM ETC. WHEN SUCH MEMBERS ARE EXPOSED TO THE WEATHER. lT BOS BOTTOM OF STRUCTURE MECH MECHANICAL 15. SLOPE ALL DECKS. PATIOS. AND WALKWAYS AWAY FROM BUILDING q MTL METAL MINIMUM OF 1/8'/FT FOR POSITIVE DRAINAGE. TISSUE PAPER TILE TO TISSUE PAPER 72' A.F.F. IM DISPENSER F.C. CPT CARPET MIN MINIMUM DISPENSER PROVIDE EXPANSION JOINTS IN ALL CONCR BS AS REQ ED DISPENSER F.CIC. MUL MULLION TO PREVENT CRACKING, SAW CUT ALL S SAS REQ'D. CLG CEILING ELEVATION ELEVATION CEM CEMENT 17. PROVIDE FIREBLOCKING. DRAFTSTOPS, AN FIRE-STOPS IN ATTICS, OORS, CENTER LINE NAT NATURAL AND WALL CAVITIES AS REQUIRED PER IBC. NOM NOMINALLIN• r GWB. PAINT C TO C CENTER TO CENTER 18. ROOF DRAINS. AND OVERFLOW DRAINS SH COMPLY W/ THE UPC & BC. • 60' 0' CLEAR CT CERAMIC TILE NA NOT APPLICABLE Itiore$0. \ FL.PI SPACEAND WALL CAVITIES AS REQUIRED PER THE C. -I FC C MIRROR < GWB, PAINT CLO CLOSET NIC NOT IN THIS CONTRACT 0 I PAPERTOWECW COLD WATER NTS NOT TO SCALE 10. DRAWINGS INDICATE GENERAL AND TYPICAL D S OF C NSTRU ON. ! OP DISPF.O.I.O. TILE 72' A.F.F. N0, ¢ NUMBER WHERE CONDITIONS ARE NOT SPECIFICALLY INDICAT z 111 I'� SEAT COVER DISP. COL COLUMNSIMILAR CHARACTER TO DETAILS SHOWN SIMILAR DETAILS OPIIIF.C.I.C. CONE CONCRETE OC ON CENTER CONSTRUCTION SHALL BE USED SUBJECT TO REVIEW BY THE ARCHITECT. N IP SOAP DISP.F.O.LO. �- 1 1/2' GRAB BARCMU CONCRETE MASONRY UNIT OD OUTSIDE DIMENSION 20. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE MEANS, a II r, A C.I.C.� 18-201 CONST CONSTRUCTION 0/ OVER METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK 4II ��� �.PM i� . FNOJtC I NUMBtK: oorNk 4 , CONT CONTINUOUS OTS OPEN TO STRUCTURE 21. CONTRACTOR SHALL RETAIN ONE SET OF THE PLANS TO NOTE AND DOCUMENT ALL I , I l� b < TILE 72' A.F.F. NORTH ARROW COORD COORDINATE CHANGES DURING CONSTRUCTION. THE SET SHALL BE A PART OF THE CONTRACTORS 16' MIN. TO COR CORRIDOR OVHD OVERHEAD CLOSE-OUT PACKAGE TO THE OWNER. SEE SPECIFICATION FOR CLOSE-OUT PACKAGE 16' MAX. CL ,MIN. ' 90N XO48' CLEAR = SHOP DRAWINGS, PRODUCT LITERATURE, EQUIPMENT WARRANTEE MANUALS. TO ADJ. WALL 5'-0' LOOK SPACE a REVISIONS: CFM CUBIC FEET PER MINUTE PLAT PAINT ® f� ` O GRID LINE PTD PAINTED 22. CONTACTOR SHALL PROVIDE SOLID BLOCKING. UNLESS NOTED OTHERWISE AS REQUIRED O MIN. PLAN ELEVATION ELEVATION 2/20/18 PERMIT/BID SET DTL DETAIL FOR NAILING OF ALL INTERIOR AND EXTERIOR TRIMS. FINISHES, AND FIXTURES. THE PL PLASTER. PLATE DIA DIAMETER P LAM PLASTIC LAMINATE INSTALLATION OF OWNER FURNISHED ITEMS SUCH AS SIGNAGE, MENU BOARDS ETC. ® 3/7/18 CITY CORRECTIONS BUILDING SECTION DIM DIMENSION PLYWD PLYWOOD r `�' DO DITTO 29. WHERE EXISTING WORK IS DAMAGED, CUT. OR DEFACED DUE TO PERFORMANCE GENERIC NOTES FOR ONE W.C. TOILET RM. DR DOOR PT POST-TENSIONED CONCRETE PRESSURE-TREATED WOOD SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL 1. UNLFSS NOTED OTHERWISE ALL DIMENSIONS SHOWN ARE MINIMUM. Ak DN DOWN BREAK LINES SUCH AS CORNERS, CEILING LINES. TOP OF BASE OR SIMILAR. 2. OVER AND UNDER DIMENSIONS INDICATE ACCEPTABLE UNITS. e I WALL SECTION D.S. DOWNSPOUT 9. DIMENSIONS SHOWN ARE ACCEPTABLE MINIMUM. AND MAY Be 24. THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT DWG DRAWING QT QUARRY TILE 4. EXPOSED DRAIN PIPES AND ALL WATER PIPES SHALL BE RECESSED, DF DRINKING FOUNTAIN RL RAIN LEADER AND MAY BE REPRODUCED ONLY WITH THE WRITTEN PERMISSION OF THE INSULATED OR GUARDED TO PREVENT BURN ACCIDENTS. amm DETAIL REF REFRIGERATOR. ARCHITECT. AUTHORIZED REPRODUCTIONS MUST BEAR THE NAME OF 5. GRAB BARS SHALL BE 1 1/4' TO 1 1/2' OUTSIDE DIA. AND SHALL BE `�Y REFERENCE THE ARCHITECT. ABLE TO SUPPORT A 300 LB LIVE LOAD WITHOUT PERMANENT DEFLECTION. EA EACHPROPER REINF REINFORCING BAR 6. PLUMBING FIXTURES AND ACCESSORIES ARE FOR ILLUSTRATIVE PURPOSES (�q INTERSECTION CORNER ELEC ELECTRICAL REV REVISION ONLY. REFER TO ACTUAL PLANS INTERIOR ELEVATIONS SPECIFICATIONS, ECT. Y INTERSECTION ELEV, EL ELEVATION R RISER. RADIUS FOR SPECIFIC FIXTURES AND AOCE55ORIES FOR THIS ELEVATIONS, EQ EQUAL7. ALL HANDICAPPED TOILET ROOMS FIXTURES AND ACCESSORIES SHALL TOP OF SUBFLOOR 1E1 EXIST EXISTING RM. RMS ROOM, ROOMS COMPLY W/ CHAPTER 11 AMEDNED OF THE 2012,IBC. ICC A117.7-2000. 2 o5 EL 10'-10 1/2'ctti ELEVATION MARK • EXT EXTERIOR RO ROUGH OPENING 8. ADDITIONAL FIXTURES SHALL BE MOUNTED AS FOLLOWS, T.P. DISP. IF LOCATED ABOVE GRAB BAR SHALL BE LOCATED WITHIN AN AREA SCHED SCHEDULE _ __ 24' MIN. AND 96' MAX. FROM REAR WALL WHERE DISPENSER IS LOCATED BELOW THE GRAB BAR, THE OUTLET OF THE DISPENSER SHALL BE LOCATED WITHIN AN SHEET TITLE: 25.00' (NEWI SPOT ELEVATION FO FACE OF. FINISH OPENING SEC SECTION zsNo ST. ` AN AREA 24' MIN. AND 42' MAX- FROM THE REAR WALL THE OUTLET OF THE 23.72' (EXIST.) FRP FIBERGLASS REINF POLYESTERSHT SHEET __ DISPENSER SHALL BE LOCATED 18' MIN. AND 48' MAX. A.F.F. DISPENSER SHALL 2M)ST. == Doi-i3o COVER SHEET ROOM-NAME FIN FINISH SV SHEET VINYL --_ BAT COMPLY WITH SECTION 600.9. DISPENSERS SHALL NOT BE OF A TYPE THAT Tot f ROOM NAME / NUMBER FAAP FIRE ALARM ANNUNCIATOR SC SOLID CORE __ = CONTROL DELIVERY. OR DO NOT ALLOW CONTINUOUS PAPER FLOW. s4TH ST. _-- -- ALLOW MIN. 1-1/2' BETWEEN G.B. AND DISP. PANT. SOAP DISPENSER OPANEL SPECS SPECIFICATIONS ISLAND HOSPITAL --- _ MAX. 40' A.F.F. BTM. EDGE OF MIRROR MAX 40' A.F.F. 2.O6 - 1 DOOR MARK FD FIRE DAMPER SF SQUARE FEET 1211 24TH ST. �/, 2STH ST. = 0. PROVIDEE TOPEN ILET TOILET SEATS PER IPA 40IIMENSI® .0. FE FINISHED END S & V STAIN & VARNISH ANACORTES. WA 10. SEE ACTUAL TOILET ROOM PLANS FOR ACTUAL DIMENSIONS AND LAYOUT. A WINDOW MARK FF FACTORY FINISH SV SHEET VINYL 2sTH ST. STRWY STAIRWAY __ 12. T.O. W.C. SEAT MIN.1T /MAX.19' A.F.F. SEAT SHALL NOT RETURN AUTOMATICALLY. FF FINISH FLOOR - = 13. FLUSH CONTROLS HAND OPERATED OR AUTOMATIC. FRT FIRE RETARDANT TREATED STL STEEL 27rH ST. ___= 14. MAX DEPTH OF LAV. BOWL TO BE 6-1/2' DEEP. HAND OPERATED FAUCETS. FLOOR MATERIAL FLASH FLASHING STOR STORAGE 1 -- SELF-CLOSING SHALL REMAIN ON FOR MIN. 10 SECONDS. z ADJACENCY STRUCT STRUCTURAL I 20TH ST. - 15. FRONT OF LAV. TO BE MAX 54' A.F.F. MEASURED TO RIM OF SINK. U FLR FLOOR SUSP SUSPENDED ALIGN F.A. FLUID-APPLIED Ali ST �� ,-- ALIGNMENT OF ITEM THRESH THRESHOLD = -m FND FOUNDATION FOIC FURNISHED BY OWNER. T.O. TOP OF /� • z / '� REVISION MARK INSTALLED BY CONTRACTOR T TREAD. THICKNESS FOIO FURNISHED BY OWNER- TEMPERED INSTALLED BY OWNER TS TUBE STEEL r- FCIC FURNISHED BY CONTRACTOR, TYP TYPICAL s21�St PJC INSTALLED BY CONTRACTOR UNFIN UNFINISHED PROJECT ARCHITECT: ELEVATION UNO UNLESS NOTED OTHERWISE MARKS GA GAUGE UR URINAL 34h1 sr. _ PJC GALV GALVANIZED DRAWN BY: GAP GENERATOR ALARM PANEL VCT VINYL COMPOSITION TILE PJC GL GLASS VERT VERTICAL CHECKED BY: GWB GYPSUM WALLBOARD VIN VINYL DTa-,Ro VR VAPOR RETARDER �20 He HANDICAP VTO VENT TO OUTSIDE A JANUARY 12. 2018 DATE HDWE HARDWARE WC WATER CLOSET HP HEAT PUMP WP WATERPROOFING 18-201.DWG HT HEIGHT WS WHEEL STOP COMPUTER FILE NAME HM HOLLOW METAL W WIDTH HOR HORIZONTAL WOO WINDOW VICINITY /� HB HOSE BIB w/ WITH MAP P %N HW HOT WATER WD WOOD HWT HOT WATER TANK WI WROUGHT IRON (in L).\\ HMD HOLLOW METAL DOOR WRGB WATER RESISTANT COPYRIGHT 2010 cAm_ar I ARCHITECTS.PS. HMF HOLLOW METAL FRAME GYPSUM BOARD I- V1 z 711. tu 0 1 H 00 *to _ j N U $ 1- CD fit` W N- UJ ON k �+ _ U o d Z • calam.. W Q iiki ib ytz, u Q Z COCCI < a Q rY^ Z I ii l Op 035 N �z f W �- gl [� OUZU W ` 1 = N u If wF. aw O Le N z U O a r m H insu� U U v Z� � � U I B I II , li 1 I i ,�— I �OM .. { I iZ.5.9 —y —. tS-11 c—.SS� € , II li ' II 3 U •V- b U r at) � I € - ri W 1 I I l.L") ' i• I % i III ,: . ... .. .... .. ........ ..... . . € . _[ y r111 .� r I 1 O ® I 4 i r f' 1 8 it i0/ _It Se !• L 9 (--\ \ C.41 79 T r fa iN1 1, r. .. . i E . . Ei1 . ,1 w - I _.. ... .. 1f .InnJI €-1i I j a •: ' ....._.. ...... . . . 1 li • l'Ic LI 12911 •. E , F-1, i . 0 2 III I La. H lir . 1 I , I € i Bol I , 1 , 40 :,.? I,: i r ocCii gge3 ! Ed Ler . .... Fil t " - - .-.. _... _ill 9' .,, IE I Ip .{E'Al FAl r.{f- ! F—.''``01 r-��;'! .'`At II Ir , 1 . ,—,f o-y I -m e1—.o-,n = 0 I, , c, T ....... . . ....... .. • , r--- I I t? g 0 I - I — I LI cr, c, ! / II y13 1 ! Ci il ® ti4.1 1 @I 0 Lre'l 'V / ®,, ._....... . . . � ft_ ., c.o 2 I ® . l 0 2 IA I iE , o E , r 'YF - M , . lit $a 0 g 0 I w . �'V �j 'i I .- I I © 1I — u ! II I 7 n O ! If AI {_ {E;01—iIi— �O9—+ "m — o-41— i no : __I it (ia I � . i C w Q_ I : N , III r-.o-5—+ \ 1 I II c+) III ii --- .o-c i sue, N •L irCI CD (..,,,, i IjI 1 :.. . 0 0 i r.rq C. :: , , 11, 11! am- :: :: __ .. . 7 i1 , , ...„.:... .. ... . . ... 11 0 :: • : ., I I �i ® q r.• •, CD ! III I 111 s i 4 ` i ' 1 ', f�} I w i �N} ! -• :::all:.: t I 1_,Q III ; (.1) ^ 1 v V , 111 Ell ! i' 1 II , ILI i 7 , ‘ i„,) 1 , . ..... ... • , \ 1 , ' w �zs l • d 1 I ll� ! I — i N• 11;; 'LI Il— � ' \ it I —1 11 I ' � � �'E`� _ I o I ! z "' J r CI 0 1` .: I , 9 • I I ,..' 1 1 1 G, I — I I Q 1:: i i r h I • ie>.. t-1 --Issnasuanarrarrurorzyrahl rz4 ! n ! ; c z - 47 1 / ! 0 - g w A ELI 11 II — Q 0 I• I. I II _ o I I w � N. F. ui i 0 1 .... . ; pp J 7 III III C.C3 CV 1 1 li I n I �1 3 —I-. e It : x ict IF i i ...- .......... h . . i I . c m . iirr 3 i{ -ter -e S 0 {:: I �I l J I . ...._.. _ ..... I . .. ... . V ' 1 ... .. . . 111 ® I I / 1 1i i 1! I I pa X � . I , Atli € 1 ... . I... .� ...`... . . . l_ . ... . . 1 8I � Q m �. % e� h; di ` I I' II J . .. . E, ! I/ j u !• it I ( k i. �j� i ,. w av ! � . j I i [ E ; g� I 1 I` X x I, i I ,� If III .......... .... . .. • E L►J I W W Ij 1 ; � . _ . . Ii � a I _ , . . . .r. . .: • , I ii in it : 1 . ' :. ; 1 11 ,I� L o l , O m 4 1 a i 1 0 . cr 0 f 11 /� {tom I € I } ' 1�1 - \ j 5 W 61 ;f.f—)rndmq—il _ �i 1 ' 11 li I ' N. i 0 - Q EDI . .. ..• I .i 1 : ' ' rl 11 Q 6Q W I 1•. Ida ,T F rr i.. • 1' 9 X C/ : I y d L) II rlIl I . \. , . Q' r 4%\\;\1 7 Ij • i EI U w l C9 3 f \...e it . 1 II I! ii 0 , f 1111 f pi 1 T gi � w I 1 I � II U. E0 it.sgizi 11 n Ii�I 1 i qQ ® c s � I EII ! I I p [� m I ; �/' ' ` .. li; w � ! �,� J l � Q !II I1 EIO I �... nd J �� - - - , � -I I ; 11 Ii• is •• it 1J ,1/4„. , I ! , " I , -- vi Q d E I , I 'E , ' r A Z ci 'T' 7 . i 11 i C) • '1 ;' W 4 i. I ;i• Q 4 in 11•, I Ii i ar 1r I .... . il; II•. g2 ,12 II ss 1II Y I W 1 III 1 E I II I , ' I." l I ' i I, r_ I ,I I 1 ,i II If Ii0....y.\\ II 1 III III I I - E 1 IE il Ili 1j II , !i ; ii ; ,• qII 1 Ill iQi ? ! I u ,� I! 1 1 ... I i I a 1Ii n rail. .1 i f E '• est ice' .'. DEMO LEGEND: EXISTING FRAMED WALL OR WALL FURRING TO REMAIN i r` , :::.,. EXISTING LOAD BEARING MASONRY WALL TO REMAIN FLOOR PLAN KEY NOTES: FLOOR PLAN NOTES: P` EXISTING COLUMN TO REMAIN 0NEW CASEWORK WITH UPPERS. SEE CASEWORK ELEVATIONS. 1• COORDINATE WITH HOSPITAL STAFF ON ITEMS TO BE SALVAGED AND SAVED PRIOR TO REMOVAL NEW CUBICLE CURTAIN TRACK AND CURTAIN. PROVIDE AND INSTALL STEEL STUD 2 NOTIFY ARCHITECT IMMEDIATELY IF CONDITIONS VARY FROM THOSE SHOWN ..-- '` PO1lOai EXISTING WALL AND OR ITEMS TO BE REMOVED O LIGHT GAUGE SUPPORT FRAMING ABOVE ACP AS REQUIRED TO SUPPORT TRACK.. OR If' UNFORSEEN ISSUES ARE DISCOVERED. RELOCATED SALVAGED DOOR AND FRAME/HARDWAREn 9. PROVIDE BLOCKING IN WALL FOR ALL F.O.LO. INCLUDING SOAP DISPENSERS. PAPER TOWEL DISP. O2 V NEW SINK WITH NEW FAUCET. SEE MECHANICAL DRAWINGS. SEAT COVER DISP- TV. CFI(INS MOUNT ECT. CONTRACTOR TO FURNISH AND INSTALL ALL GRAB BARS. CARLETTI ARCHITECTS Fos, SEE DOOR SCHEDULE SHEET A-29 _ _ architecture,panning,interior aaign DEMOLITION KEY NOTES: ONEW TOILET AND LAY. MATCH EXIST. SEE MECHANICAL DRAWINGS. 116 EAST FFIR STREET O REMOVE EXISTING NON-BEARING WALLS AS NOTED. O EQUIPMENT/FURNITURE F.O.I.O. SUITE A MOUNT VERNON. WA. 98273 O GRAB BAR F.CLC_ PROVIDE BLOCKING IN WALL AS REQ'D. EXIT PLAN NOTES: O REMOVE EXISTING DOORS/FRAMES. SALVAGE POOR RELOCATION/REUSE FLOOR PLAN LEGEND: Phone: (3601 424-0394 ONEW CASEWORK SEE CASEWORK ELEVATIONS. t TRAVEL DISTANCE TO COMMON PATH OF TRAVEL e 75'-0' PER Fax: 360 424-5726 OREMOVE EXISTING PLUMBING FIXTURES. CAP EXIST. PLUMB. FOR FUTURE USE • ` EXISTING FRAMED WALL OR FURRING TO REMAIN TABLE 1014.9 W/O FIRE SPRINKLERS [OK) SALVAGE FIXTURES AS DIRECTED BY OWNER. O CORNER GUARD ._...._....: EXISTING LOAD BEARING MASDRNY WALL TO REMAIN 2 OVERALL EXIT TRAVEL DISTANCE a 200'-0' FOR IBl QCC. WITHOUT 4 REMOVE EXISTING CASEWORK. SALVAGE AS DIRECTED BY OWNER. : EXISTING STRUCTURAL COLUMN TO REMAIN SPRINKLIRS PER TABLE 10102 IOKI O FOR PLUMBING AND ELECTRICAL CONNECTION NOTE THAT THERE IS SPACED BELOW NEW WALL FRAMING OR IWALL SEE WALL TAGS NEW WALL FURRING SEE WALL TAGS 5. III EXIT PROVIDED AND I1) ARE REQUIRED PER 1015.1. SINCE WE HAVE �� E ED THE REMODELED SPACE FOR ACCESS FOR PLUMBING AND ELECTRICAL LESS THAN 50 OCCUPANTS LOAD. IOK1 ITECT O REMOVE EXISTING FLOORING. VINYL RUBBER BASE. TYPICAL WITHIN EXIST. SPACE. O DOOR TAG SEE SHEET A-29 I lot I ROOM NUMBER SEE SHEET A-2.9 P&I'ii B "M VASTINGEW O SEE MECH. DWGS. FOR DEMOLISHED DUCTING AND PLUMBING FIXTURES. TYP. T WALL TAG NUMBER SEE SHEET A-25 I ® REMAS DIROVE ECTED ALL EXISTINGBYO W ACP GRID. CEILING PANELS AND LIGHT FIXTURES. SALVAGE r 2A1OBC FIRE EXTINGUISHER IN CABINET NER TYP. F O RELOCATED ELECTRICAL AND OR DRA REMOVE/WINGS Mi TtODIFY ALL FIRE ALARM HORNS AND STROBES. DIRECTIONAL EMERGENCY EXIT SIGN HARDWIRE ISLAND HOSPITAL 0 . q p W/ BATTERY BACKUP PRIMARY CARE CLINIC COORDINATE ALL MECHANICAL/ELECTRICAL ROUGH IN PRIOR TO ANY COVER OF I-1 COMBINATION EXIT SIGN/EMERGENCY LIGHTING W/ EXPANSION AND IMPROVEMENT 10 WALLS AND OR CEILING CAVITIES. COORDINATE ALL ROUGH IN MECHANICAL q BATTERY BACKUP HARDWARE AND PLUMBING REQUIREMENTS FOR EQUIPMENT WITH TENANT. TYP. I P OB GYN CLINIC EMERGENCY LIGHTING W/ BATTERY BACKUP HARDWARE 0 REMOVE EXISTING WINDOW AND FRAME ISLAN.D HOSPITAL O REMOVE EXISTING DOOR AND FRAME. 19 REMOVE DRYWALL AS REDO. AT EXIST. EXTERIOR FURRED WALLS TO ALLOW FOR NEW ELECTRICAL DEVICES AND CONNECTION TO NEW RELOCATED ELECTRICAL PANEL CONTACT: MIKE MCKENNA • PATCH/FILL IN WALL AS REQ'D AT FORMER SHAFT LOCATION L 0 - 1 J --- JJ /,�II — __ — — _ \ oPENING ILO EXIST. f lI J g // II 12 1 COLUMN -....._ t ti o b o I I [_ LTT _ 9 � 8-201 I OSTOR. �/ ® - - - - -.. t1I 0� _Jai I--� I 5 0 i 4 111 � ► •. I I I I 1 © �� 1 j O t DO• ORS HLLI i 1 4'-0' g'D ' t2 EXAM-5 t9 9 t� • REVISIONS: :'L—J —�. J _ f_ _ 1124 t14 101 a ��- • I ��� © EIL1 r a _ 72/20/18 PERMIT/BID SET . I EXAM-1 2 - .FILL IN O— _ - J 1 1 I 0 t - I 0 1 LJ 0 I EXAM-4 EXIST. —� 1 ;I I _ Q I 1 Fes/ 0 I O tto 2— I ,O - i, wttlR#N- - • — ,..._._ , 0 T = — 1 i I / J -- I NEW 0' CONC. SLAB I 1 . I I ---- -iT---� I I 9LOFORPI�AWAY FROM 1 10 �]_... I O L--- "e J I i BUILDING TYP. ; © MA'S/RN'S ;if- <_ L_-J THICKEND EDGE ail I t g 119 ® O _. :... - ... - 12' DEf3P a PERIMETER �.... __._..: T - I I , 9. . ,.._, ::: ;•.,. .. . • • _1 , I O ��� e O �� O O © O ... _ -- ® 1 — EXAM-2 2 I I I / 0 O._, -I I I =-==i - - W 1os �'' SHEET TITLE: EXAM 3 _ i ,!!� LL IN 6---�© LL �LJ ® // I �© to® — -'- 1 1. 411 Do R OPENING DEMOLITION FLOOR PLAN j I I I O -I 1 ® A HALL ®, n , I I I I 0 I toa Q PROPOSED FLOOR PLAN ':I IEXIST. _ I I I ® t ® t 0 .. I Q 1 v 0 COLUMN 1 j - - _ _ _.:. ...' STUDS-,�= ---R . rFi r� F- \ II 11 II \ • _ a - 2 / .` f 1 .._....... © 1 I VESTIBULE III 11 /l F, �\ II� II i rr 1- r Q SCALE �. , 1 1-� I 9 U�� II L-- O - : -1 ��� 1 � - II „ ULTRASOUND � r ., � L .L@ ' 55 5 O toe CLEAN - _-_-11 O O tO L_ I' =�; O-. DIRTY - °-° °.'� 105-I I A55THRU 108 LJ - --F r r----� I , — 7/8 EXAM-6 :! a I '1 i , ©Y I ;A.,_., ,as 104 [Il �I 1 4 9 O Q4 INSTALL BLOCKING I � R07 • riI I I PROJECT ARCHITECT: ——`—— / IN CEILING ABOVE ACP 1 0 o- T \ i- , -i rr _l� RI rt FOR CEILING NITD. -- I PJC O O ® OIIL--I. I----- ® --- -1 �L.a -- TELL I; MONITOR O — - - ——__._. __ L---- L J�I l..(.,J u' P �� DRAWN BY: ,. .• :. . .,, ... .....:.......::::..:.......::::... PJC © O CHECKED BY, �''� I JANUARY 12. 2018 DATE ' 18-201.DWG COMPUTER FILE NAME .,.:1--. DEMO/EXISTING PLAN /(2 •.PROPOSED FLOOR PLAN _ 1/4'4-0` I 1/4'•1-0' `® ® �PTRIO NT 1016 OiRLE7l7 ARCH!:r Ty P1 \- V� N; f CARLETTI ARCHITECTS P S. architecture,planning,interior d ign 116 EAST FIR STREET SUITE A - MOUNT VERNON, WA. 98273 PROPOSED CEILNG LEGEND: Phone: (3601424-0384 x9 NEW 2X2 LED LIGHT FIXTURE SEE ELECTRICAL DWGS. Fax: 360 424 5726 NEW 2X4 LED LIGHT FIXTURE SEE ELECTRICAL DWGS. 6429 E TERED 0NEW OCCUPANCY SENSOR SEE ELECTRICAL DWGS. ITECT NEW UNDER CABINET SEE ELECTRICAL DWGS. —— Fknial a NEW LED CAN LIGHT SEE ELECTRICAL DWGS. STATE ronSI¢NGTav ® NEW LED VANITY LIGHT/WALL MTD. SEE ELECTRICAL DWGS. DEMO CEILING LEGEND: iZ1 NEW DIFFUSER SUPPLY GRILLE SEE MECHANICAL DWGS. ISLAND HOSPITAL EXISTING LIGHT FIXTURE SALVAGE AS DIRECTED I� NEW RETURN MR GRILLE SEE MECHANICAL DWGS. PRIMARY CARE CLINIC EXISTING RETURN AIRIDIFUSSER GRILLE REMOVE ca NEW SPEAKER SEE ELECTRICAL DWGS. CONNECT TO SYSTEM EXPANSION AND IMPROVEMENT OB GYN CLINIC EXISTING CAN LIGHT REMOVE SALVAGE AS DIRECTED dam, REMOVE ALL EXISTING SUSPENDED CEILING GRID . I(' 'L- �D HOSPITA . AND TILES TYP. ENTIRE SPACE 1 1 1 i. CONTACT: MIKE MCKENNA L --I -- II 'eN 'N, '. JII / II r,—., — rir — � zql-lan J KUJCI NUMtbR` 11 li -i-� i i i i �/ �� I :- REVISIONS: )—T-1 j F� I i� (� (� ®2/20/18 PERMIT/BID SET • 1 I \� 1 Gc _ \ \ tr) 7 II --_ II OC ! H rZE- - ----J I / 1 r. _. . .. , .. - I , -�, 1 • O •t ll 1J.1 I F 11 j • . : 11 T u 1 -- 1 8 l OC i . i L LL———— �� =J� I : LJ L--J -, i 1; 1 j 1 —1 I I •====I II v \l x W SHEET TITLE: :j / LL �J / A �. — — i gI 0 �� DEMOLITION CEILING PLAN �1 I PROPOSED CEILING PLAN I 1 I II ,�� —— 0 ----- ---------— --1 r .3 F— \ 11 II I�`\ 1 II 1 1 111 III / \ II �� II i�� ; U '\ III111 ' L1�J II i i -- : x I \\1 1.—� 1 �� . u—� II \L— I a i PANEL. i sI 1i ` — — OC I r-----1 oc Ig i T 1 II II 0 1 N N sa.Y PJC LL I 1 0 1 I :, PROJECT ARCHITECT: Ir r I$ _ �. 1 I I PJC \ f� Ifr rr I F 1- I}: 1 g IL — 1 \l TEL. L LI_�jl, s DRAWN BY: RILi` s PJC © ® CHECKED BY: JANUARY 12, 2018 DATE 18-201.DWG COMPUTER FILE NAME 1 DEMOIEXISTINC C®ILII� C PLAN ' D 2 PROPOSED CEILING PLAN „ A . . 1/4'.1' 0' � 1/4'�1`-O' cot'rtttatrT 2018 CAR artcirrecr&Ps. DOOR SCHEDULE ti NO. SIZE DOOR LEAF FRAME CLOSER RATING PANIC HARDWARE NOTES I TYPE MATL. FIN. MATL. FIN. GROUP :;AI 1 3'-0' X 6'-8' C WD CLR HMF PNT YES - - - NEW DOOR AND FRAME REUSE EXISTING LEVER HARDWARE FROM EXISTING ENTRY DOOR 1 2 3'-0' X 6'-8' A WD CLR HMF PNT - - - - REUSE EXISTING DOOR AND FRAME EXIST. LEVER HANDLE HARDWARE -� 3 3'-O' X 6'-8' A WD CLR HMF PNT - - - - REUSE EXISTING DOOR AND FRAME AND EXIST. LEVER HARDWARE DOOR TYPES GAALETTI ARCHITECTS Pa 4 3'-0' X 6'-8' A WD CLR HMF PNT - - - - NEW DOOR AND FRAME AND NEW LEVER HARDWARE MATCH EXIST. 5 3'-0' X 6'-8' B WD CLR HMP PNT YES - . - REUSE EXISTING DOOR AND FRAME AND HARDWARE ADD A CLOSER AND 5.S. KICKPLATES I ardliacture,planning,interior dixgn 6 3'-0' X 6'-8' A WD CLR HMF PUT YES - - - REUSE EXISTING DOOR AND FRAME AND EXISTING HARDWARE LEVER HANDLE PRIVACY LOCK 116 EAST FIR STREET 7 5'-O' X 6'-8' A WD CLR HMF PNT - - - - NEW DOOR AND FRAME AND NEW LEVER HARDWARE MATCH EXIST. T T SUITE A 8 9'-O' X e'8' A WD CLR HMF PNT REUSE EXISTING DOOR AND FRAME NEW LEVER HANDLE HARDWARE MATCH EXIST. -- MOUNT VERNON, WA. 88273 0 3'-0' X 6'-8' A WD CLR HMF PNT - - - - NEW DOOR AND FRAME AND NEW LEVER HARDWARE MATCH EXIST. 10 3'-0' X 6'-8' A _ WD CLR HMP PNT - - _ - EXISTING DOOR AND FRAME AND EXIST. LEVER HARDWARE TO REMAIN 11 3'-0' X 6'-8' A WO CLR HMFFax: ( PNT - - - - EXISTING DOOR AND FRAME AND EXIST. LEVER HARDWARE TO REMAIN Phone: 424- F 360 424-572726 12 3'-0' X 6'-8' A WD CLR HMF PUT - - - - REUSE EXISTING DOOR AND FRAME NEW LEVER HANDLE WITH KEYED LOCK HARDWARE j3 3'-6' X 6'-8' A WD CI-R - - NEW POCKET DOOR WITH BARRIER FREE HARDWARE NOTES TYPE A TYPE B TYPE C T=TEMP 1. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. m- �Za 2. ALL GLAZING WITHIN A 24 INCH ARC OF EITHER EDGE OP DOORS AND WITHIN 18 INCHES OF FLOORS SHALL BE SAFTY GLAZING AS F. F: E SILEED REQUIRED BY IBC SECTION 2408.3. ALL SUCH GLAZING SHALL HAVE PERMANENT IDENTIFICATION SAFTY GLAZING STAMP. ITEM' 3. DOORS SHALL HAVE LEVER HARDWARE WHICH WILL PERMIT OPERATION BY WRIST OR ARM PRESSURE 4. DOOR SPECIES TO MATCH EXISTING MAPLE. DOORS TO BE 1-3/4' SOLID CORE. -F- _ - - J. STA OF it FINISH SCHEDULE ROOM ROOM FLOOR BASE NORTH WALL SOUTH WALL EAST WALL WEST WALL CEILING NOTES. NUMB. NAME MATL FIN. NO. 'MAIL FIN. NO. MAT'L FIN. NO. MATL FIN. NO. MATL FIN. MATL FIN. MATL FIN. NO. HOT. 113 100 101 HALL LVT FF LVT-1 VRB FF VRB-1 GWB PNT P-1 GW8 PHI' P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 T-8' ISLAND HOSPITAL 102 EXAM-1 SV PP SV-1 VRB FP VRB-1 GWB PNT P-1 GWB PUT P-1 GWB PNT P-1 GWB PNT P-1 ACP PF ACP-1 T-8' PRIMARY CARE CLINIC 103 EXAM-2 SV FF SV-1 VRB FF VRB-1 GWB PNT P-1 GWB T P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 T-8 EXPANSION AND IMPROVEMEN 104 EXAM-6 SV FF SV-1 VRB FF VRB-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF L ACP-1 7-8' PENCIL ,-.` OB GYN CLINIC r- 10S CLEAN SV FF SV-1 SV FF SV-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 7-8' COVED SHEET VINYL BASEiii DRAWER I l - 108 DIRTY SV FF WB SV-1 SV FP SV-1 GWB PNT P-1 G PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PUT PNT-1 7-8' COVED SHEET VINYL BASE 107 RESTROOM TILE FF T-1 TILE FF T-2 TILE/GWB' PNT P-1 TILE/GWE PNT P-1 TILE/GWB PNT P-1 TILE/GWB PNT P-1 GWB PNT PNT-1 7-8' TILE TO 72' AF.F. GWB PAINTED ABOVE SUPPORTS �p_0 [;: i -,Ar 108 ULTRASOUND SV FF SV-1 VRB FF VRB-2-GWB PNT P-1 GWB PNT P-1 'GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 T-8' II s "' 11OITfL .9` �_�— F.E. �c 100 EXAM-3 SV FF SV-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PHI P-1 ACP FF ACP-1 7-8' _ CONTACT: 110 EXAM-4 SV FF SV-I VRB FF VRB-2 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 r-8' m T .......... .1 ' ' MIKE MCKENNA 111 STOR. SV FF SV-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT P-1 GWB PUT8 P 1 GWB PNT P-1 ACP FF ACP-1 T- ' m m .3112 EXAM-5 SV FF SV-1 VRB FF VRB-2 OWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 7-8' �_�, `� " ., 115 MA'S/RN'S LVT FF LVT-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 )'-8' .1._ ...._..._.___.�..._......_- _ _ I �_ .-- ` I. t_. \ _ 1: 114 DOCTORS CPT FP CPT-1 VRB FP VRB-2'GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 'ACP PP ACP-1 T-8' CARPET TILES 16 MA'S 4MA'S 8MA'S ORN'S 1/4' = 1'-O' 1/4' = V-O' 1/4' 0 1'-0' 1/4' 4 V-0' INTERIOR MATERIALS LEGEND ABBREVIATION DESCRIPTION $ SIZE MANUFACTURER, STYLE. COLOR. NOTES. FLOOR/BASE: LVT LUXURY VINYL TILE 1 MANNINGTON _ SV SHEET VINYL 1 ROLLED GOOD - - MANUFACTURER'S STD. SELECT - SV COVED SHEET VINYL 2 4' H - - MANUFACTURER'S STD. SELECT - CPT CARPET TILES 1 24'X24' - - MANUFACTURER'S STD. SELECT - 18-201 VRB VINYL RUBBER BASE 1 4' H 'JOHNSONITE - MATCH EXISTING MITER ALL CORNERS HRUJtC.I NUMIitR: VRB VINYL RUBBER BASE 2 4' H JOHNSONITE - MATCH •EXISTING MATCH EXISTING . TILE PORCELAIN TILE FLOORING 1 12'X12' TILE - - MATCH EXISTING MATCH EXISTING • TILE PORCELAIN TILE WALL 2 12'X12' TILE - - MATCH EXISTING MATCH EXISTING — L— UI.. -`I REVISIONS: GROUT EPDXY GROUT 1 - MARPEI MATCH EXISTING MATCH EXISTING 7 DRAWER BELOW A 2/20/18 PERMIT/BID SET PAINT: ii U rip. AS SHOWN PNT PAINT 1 - SHERWIN WILLIAMS EGGSHELL - MATCH EXISTING `.. PNT PAINT 2 - SHERWIN WILLIAMS EGGSHELL - MATCH EXISTING CASEWORK: 1 DOCTORS DOCTORS `_ - P-LAM PLASTIC LAMINATE 1 SHEET GOOD FORMICA STANDARD - COUNTERTOPS 114 114 P-LAM PLASTIC LAMINATE 2 SHEET GOOD FORMICA STANDARD - CASEWORK FACES DOORS/DRAWERS CEILING, ACP 1 ACOUSTICAL CEILING PANEL 1 12' X 4' I ARMSTRONG I FINE FISSURED HIGH NRC 1728 -I WHITE 1 SQUARE LAY-IN WI 15/16' SUSPENSION SYSTEM COLOR WHITE __ FABRIC _._ __. • r1 '= oITIWRAPPEDPARTON TYP... . N` PENCIL DRAWS E 0 o P.LAM B.S. d N ® COUNTERTOP S. .: .: — = SHEET TITLE: 0 o m • N DOOR SCHEDULE • FINISH SCHEDULE 1- ULTRASOUND ®DOCTORS ODOCTORS FINISHES 1/4' 0 1'-0' 1/4' a 1'-0' 1/4' 0 1'-O' INTERIOR ELEVATIONS , - - — — — — - - II'I — - - - - - } �I. � — — — - - - - -i el -- - - - - 1--- - - ramPLINJ - - - - 7 - - - - EXAM-1 EXAM-2 EXAM-3 EXAM-4 01 EXAM-5 I I CLEAN CLEAN I DIRTY DIRTY 102 103 110 112 I PROCEDURE I 105 105 I 106 I 106 1O® PJC 104 SHELVES W/ BRACKET SUPPORTS PROJECT ARCHITECT, AS READ . . PJC I I > I .l. — — DRAWN BY: E::: I N I: I: I l I - ' E l 1. PJC C I:: ( 11::: ( / 1 I ( - f 1.; I: I .I;' I I I 1 fi °-�;' I r' I_' ( f I 'I j f [••• ....I. I 1 i ' . 1..... -- I AU FROM = CHECKED BY: �OUNTER TO BTM. FOAM B.S. 6 COUNTER TO BTM. SHELVES N 7couNTERrDP rY . �UPPERs • JANUARY 12. 2018 . . .. 1� u- SINK- 1— I { I _. . .. J_J _ I : DATE • 18-201X T� I -L COMPUTER DWG (,... I. I . . • l :, �w I w"-f- I I I. 1, I . 4 1—i :: i .I . i .... 1 • 7- 1+r ,I .......... FILE NAME I EXAM-1 QEXAM-2 3 3EXAM-� 4 EXAM-4 ()EXAM-5 EXAM-6 CLEAN ( 9 CLEAN DIRTY 10 DIRTY6 COPYRIGHT 2010 CARLETTIARCHTTECT9.P.9. 1/4 1'' . -0' 1/4' - 1'-O' 1/4' - 1'-O' 1/4' = 1'-0' 1/4' - 1'-0' 1/4' . 1'.-0' �'� 1/4' . 1'-0' 1/4' - 1'-0' 1/4' - V-O' 1/4' = 1'-0' 8'-0' A.F.F. U.N.O. I 9 ' MTL STUDS I� 90 MIL o 16' O.C. Q 8'-0' A.F.F. 8'-0' AF.F. Q (1' U.N.O. U.N.O. • I. 9 ' MTL STUD FURRING 6' MTL STUD 30 MIL 0 16' O.C. O 90 MIL 0 16 O.C. _--- _. 1 __. ._ � ' 'X' GWB (GREENBOARO O '; .., r RESTROOMSI PAINT TYP. VAPOR BARRIER � 1 R-15 BATT INSULATION I CAR p I?. J ::.., a 'X GWB PAINT d t a a�• LETTI ARCHITECTS " �' SOUND GATT INSULATION architecture, arming,in erior ign 1 X' GWB PAINT BASE AND FINISH EXISTING BRICK WALL i 116 EAST FIR STREET PER SCHEDULE SOUND BATT INSULATION SUITE A MOUNT VERNON. WA. 98273 -- / 1:.: ...-..., TBASE FINISH Fax:Phone `360) •42�4-05726 BASE & FINISH PER SCHEDULE 384 PER SCHEDULE FRAME WALL TO MIN. 8'-0' A.F.F. 6429 5 KICKER TO ABOVE WITH STL SUPPORTS FRAME WALL TO MIN. 8'-0' A.F.F. FRAI.IE WALL TO MIN. 8'-0' AF-F. E TERED ITECT SEE DETAIL 15/A-0.0 2 KICKER TO ABOVE WITH STL SUPPORTS 1 KICKER TO ABOVE WITH STL SUPPORTS SEE DETAIL 15/A-6.0 I SEE DETAIL 15/A-6.0 1 ski It STATE VASIENGTUI STEEL STUD KICKERS 0 5.-0. O.C. FRAME TO STRUCTURE ABOVE MTL STUD WALL PER ` % WALL TYPES , ISLAND HOSPITAL MTL STUD WALL PER SOUND BATTS LAY-IN FACED SOUNDIDEPRIMARY CARE CLINIC \ y WALL TYPES I TOP OF WALLTYPE [ ..... IMPROVEMENT r — -� EXPANSION AND L • ' ' I �� SOUND BATTs SHIM SPACE B GYN CLINIC ~tip z __ •"` H_ SHIM SPACE ," s I :_ GWB CONTACT • ,-.- - CEILING RUNNER WI AC.T- I /".:--< 5/8' TYPE 'X' - FASTEN RUNNER TO PARTITION BOTH SIDES HOLLOWIT MTL FRAME MIKE MCKENNA PROVIDE ACOUSTICAL SEALANT I— AT ALL GAPS BETWEEN CLG I & PARTITION 5/8' "X' GWB EA SIDE II I HOLLOW MTL FRAME DOOR PER SCHEDULE V DOOR PER5/8' TYPE 'X' GWB SEE WALL TYPES SCHEDULEE BOTH SIDES. FINISH/PAINT ,.....� PARTITION KICKER DETAIL OH . V .F. HEAD ®, .M . F. JAVB \,,__,,/ N.T.S. N.T.S. N.T.S. SUPPORT WIRES 18-201 ' SEE ACTT- SWAY l-NUJtG 1 NUMBEK: BRACE DETAIL TYP. VERTICAL 12 GA HANGER WIRE -- i-- / SPACED 4'-0' O-C- ALONG MAIN BEAM ALL WIRE TIES ARE TO Be I51 VERTICAL STRUT CAPABLE TO STRUCTURE ABOVE. TIGHT TURNS AROUND ITSELF OF RESISTING VERTICAL REVISIONS: WITHIN 5' LOADS 0 Z12'-0' O.C. SEE WALL TYPES BEGINNING s.6'-0' FROM (41 12 GA WIRES SECURED TO HD ®2/20/18 PERMIT/BID SET WALL I MAIN BEAM WITHIN 2' OF CONNECTION OF VERTICLE STRUT TO MAIN BEAM SPLAYED 00 DEGREES - • -.- RAMSET ANCHOR �t/1 FROM EA. OTHER 45 DEGREES MIN. -III�' yv FROM CLG PLANE. LATERAL FORCE ` w 24' O.C. = ` 1,<47: t.$‘ BRACING SHALL BE PLACED 12'-0' 0.C- '' IN BOTH DIRECTIONS. W/ THE FIRST I 1' NEP POINT WITHIN 6'-0' FROM EA WALL. �' SECURE TO STRUCTURE ABOVE.BASE FINISH —�. " [PER SCHEDULE"` HD MAIN BEAM Q c c c� T o o - 0 Cpo -y 83 CROSS RUNNER _ im' NOTE SUSPENDED CLG SHALL BE INSTALLED PER ASTM C856. NOTE. HANGER 6 PERIMETER WIRES MUST BE PLUMB WITHIN 1 IN 6 SHEET TITLE: CISCA ZONES 5-4 & ASCE 0.0.2.6.2.2 UNLESS COUNTER SLOPING WIRES ARE PROVIDED. DETAILS--- BASE DETAIL CE8) WIRE f IE C =ILI \ G BRACE A.C.T. SWAY BRACE 1�� N.T.S. N.T.S. C N.T.S. N.T.S. VERTICAL 0 GA HANGER SPACED 012 GA. WIRE HANGER TO r 4'-0' O.C. ALONG MAIN RUNNER TO / STRUCTURE AT EACH STRUCTURE ABOVE. STRUT `/ CORNER OF FIXTURE COMPRESSION STRUT o i2'-0' O.C. 0 12'-0' O.C. ATTACH SLACK WIRES I4I 12 GA WIRES SECURED TO MAIN DIRECTLY TO FIXTURE RUNNER- 12 GA SWAY SUPPORT AT DIAGONAL CORNERS SPLAY 00D FROM EA OTHER N.T.E. WIRES ® 12'-0' O.C. SEE DTL 5/A-6.2 SEE:OTL 6/A-62 45 FROM CLG PLANE. HORIZONTAL r-VERTICAL PJC o 0 0 o0Q o Oo O RESTRAINT POINTS SHALL BE PLACED`�o © � o 0 12'-0' O.C. IN BOTHDIRECTIONS, W/ 0 GA SUSPENSION WIRE THE FIRST POINT WCfFi1N 4._No FROM 0 4-0' O.C. PROJECT ARCHITECT: 45 EA WALL SECURE TO STRUCTURE COLD ROLLED CHANNEL PJC WALL MOLDING J/ ABOVE. 0 4-0' O.C- N• MAX 18 GA TIE WIRE DRAWN BY: i 1/2' COLD ROLLED CHANNEL PJC ATTACH FIXTURE TO /1. e 4'-0' 0.C. 4107 CEILING SUSPENSION I / CHECKED BY: /` 7/8' HAT CHANNEL SYSTEM WITH PostrtvEII, 0 2'-0' 0.C- JANUARY 12. 2018 6 CLAMP DEVICES HAVING DATE A-6 2 CAPACITY OF 100X OF f LIGHTING FIXTURE WEIGHT IN ANY DIRECTION NOTE: (11 ENO OF CEILING GRID SHALL BE ATTACHED TO WALL " MAX. TIP. MOLDING, THE OTHER END SHALL HAVE A 5/4' CLEARANCE FROM 18-201ER FILE 1 COMPUTER FILE NAME WALL 6 FREE TO SLIDE- GRID SHALL BE ATTACHED AT (21 \ HAT CHANNEL ADJACENT WALLS (POP RIVETS OR APPROVED METHOD) 5/B' GWB a 2-0' O.C. LIGHT I= IX. SUPPORT C3 GRID AT WALL C2- SUSPE \ DED GWB N.T.S. N.T.S. N.T.S. COPYRIGHT 2016 LARLETim ARCHITECTS. P.4. II : . it '''' ..:'''....'-'''' .„...; , :1 • . ::;.,;„._._, ._ t 1 5 i 1 "� CARLETTI ARCHITECTS P.S. ,__ ' _.. architecture,planning,interior design .. - • . 1 j .i ,,j 't. 116 EAST FIR STREET ` ! '' SUITE A —' N c MOUNT VERNON. WA. 88273 I �� Phone. (360I424-0384 € 1 F � 0 Fax 360 424-5726 a .\_ 8429I =z - _ :1.��.. � �' , STEREO ' �w? ' ---- _ I ITECT OFFICE _ -•__ - "- ::Y 5iAiE MJSHNCN i k STAID € . : OOFFICE ` 1 .1 i . ISLAND HOSPITAL ' EXAMISE PRIMARY CARE CLINIC 1 1111rIyy...py ---_..--- ril - EXPANSION AND IMPROVEMENT —� ;.: ,. € .P1P OB GYN CLINIC I I -r EXAM-- 1 — � 1 �� �1 ;, V I I LAB' 0 EXAM0 OFFICE � 27 (� 125124 22 21 20 18 (17j 16j 15 14 12) 111 (110SLAN HtOSPITAI , �a� _ Fol) ii--.- f n n n_ ,�'�" r,21)1 CONTACT: ..i, ▪:,▪......, _,_ EXAMS: L - MIKE MCKENNA �tF ,=.�g PROCEDURE EXAM 72) �y ft BREAK Ewllt 5-08 �: ® ® El @7 � ;� 1V • ISLAND ®i n1-0� f�I to 19 .1- SURGEONS. 23 ® 12 13j EDI ID ® P 109 •.... BREAK Fi�1A — C� OFFICE I.S., INC. SCHEDULING • PROCEDURE JHOBGYN ! ® �_ Art s-03 U 11 4p �. ■ 101 — i ■ CUT f 1 ,;. 108 I _ ( J037 EQ571\oTSC0. ... R-,v C)._._=I t 123i ti` i '0 116� 107J MAIN EXIT EXISTING COMMON AREA `\ =- lip � 18-201 W/ PANIC HARDWARE �a ® ® ® I'KUJCC,I NUMBCK. - 1 EXAM Eu% S�PIYGAE� I FM-03.__:: i �........ REVISIONS: Q® 1...1] V AL0)tDI „.- - lill 0 2/20/18 PERMIT/BID SET I- l ( 1 0 0 4 16j 0 n 104 105 ( 106 -- FAMILY `OATB1 .._._..._.. OFFICE ! , PHARMACY I i :..._.�._ .<...:.../ . J 1 = r�,...:.....1=0 II r \ 10.4.4__ 7. MD 1-10-0'�' w --11'•71 �,,i'o LUNCHROOM — EXAM EXAM �I�CB' -SFr' bEt ®[t IE18 2. Irrj.: I I , I o �1 ` .px,..,, FM-01 xnlum,�. , ,3I , Iiiil EXAM EXAM MANAGER �°� FIDALGO ® _ '`—$ �' tan alpOFFICE ® n�aTss,n — (�` DI�A� j SHEET TITLE: "�"S" (u� o' MAIN EXIT EXISTING € L IE-14 (FA4,l 0 V Qj W/ PANIC HARDWARE ` € {� T A 4-40'� f` ` r Mil- -_ OVERALL FLOOR PLAN '�' — 6 6REAKWAY PANEL 11 ASSOCIATES IE-24 TR in OFFICE m® asm® ✓-or P TrIS MIN cavrsrsaw:u • rn r-o-FA-¢-1 xc n roxHwuT ::<.1 \ -X.GIASS — _ — I \ tQ'-Si.r—ra--,t�T-¢a--I � , p �+-, A-2.1 r®1 NORTHWEST O OL01GYierm — OE'o� 4 IE-16 OFFICE .,I� a1 d16 Y I iaccaPaoals g:a:,w �7 _ CFO nra.� n "tt"`I 'PIT W15 WI ISLAND EYE T1 SUB �/ST 18"� tt.• au� wq Fa SURGEONS & § E e w� IE•O7 Eu'� EXAM IE-04 �� `- _ �p T `.. '" ; '' 11 PHYSICIANS, INC. - :'�-1 1._,..._,.. ./3p t--S� IE-08 �_ �� MAIN EXIT EXISTING .r GO �r•- R • rr®r - W/ PANIC HARDWARE F—r.,• JJ„I5- i_ a ... d BREAMAY PANELLAB ®� — — — — IE-01 CHARTS LARGE EXAM I— — BILLERS 4 EXAM PJC rr �` IE-05'kr § IE-06 IE-09 4-0 EXAM PROJECT ARCHITECT: IE-10 PJC 21'-1D�' - �1711 ��t� tr�� MD t00� DRAWN BY: � 1 I-..- I( PJC 6va� rl CHECKED BY: JANUARY 12, 2018 DATE 18-201.DWG COMPUTER FILE NAME OVERALL EXISTING FLOOR PLAN COPYRIGHT 2016 fHR1 LlR7 ARCHITECTS.P.S. DEMO LEGEND: EXISTING FRAMED WALL OR WALL FURRING TO REMAIN FLOOR PLAN KEY NOTES: FLOOR PLAN NOTES: ::ZZ; EXISTING LOAD BEARING MASONRY WALL TO REMAIN 11 EXISTING COLUMN TO REMAIN NEW CASEWORK WITH UPPERS. SEE CASEWORK ELEVATIONS. 1. COORDINATE WITH HOSPITAL STAFF ON ITEMS TO BE SALVAGED AND SAVED PRIOR TO REMOVAL. URAIN TRACK AND CURTAIN. PROVIDE AND INSTALL STEEL STUD 2. NOTIFY ARCHITECT IMMEDIATELY IF CONDITIONS VARY FROM THOSE SHOWN MO EXISTING WALL AND OR ITEMS TO BE REMOVED O NEW CUBICLE CTLIGHT GAUGE SUPPORT FRAMING ABOVE ACP AS REQUIRED TO SUPPORT TRACK.. OR IF UNFORSEEN ISSUES ARE DISCOVERED. ® RELOCATED SALVAGED DOOR AND FRAME/HARDWARE 9. PROVIDE BLOCKING IN WALL FOR ALL F-O.I.O. INCLUDING, SOAP DISPENSERS. PAPER TOWEL DISP. SEE ODOR SCHEDULE SHEET A-2.9 ONEW SINK WITH NEW FAUCET. SEE MECHANICAL DRAWINGS. SEAT COVER D1SP, TV. CEILING MOUNT ECT. CONTRACTOR TO FURNISH AND INSTALL ALL GRAB BARS. CARLETTI ARCHITECTS poS, architecture,panning,interior design DEMOLITION KEY NOTES: O4 NEW TOILET AND LAV. MATCH EXIST. SEE MECHANICAL DRAWINGS. 116 EAST FIR STREET OREMOVE EXISTING NON-BEARING WALLS AS NOTED. O EQUIPMENT/FURNITURE F.0.1.0. SUITE A MOUNT VERNON, WA. 08273 2 REMOVE EXISTING DOORS/FRAMES. SALVAGE FOR RELOCATION/REUSE O GRAB BAR F.C.I.C.. PROVIDE BLOCKING IN WALL AS REQ'D. EXIT PLAN NOTES:0FLOOR PLAN LEGEND: Phone: 360 424-0304 0 NEW CASEWORK SEE CASEWORK ELEVATIONS. Fax: 1360) 424-5726 O REMOVE EXISTING PLUMBING FIXTURES. CAP EXIST. PLUMB. POR FUTURE USE 1. TRAVEL DISTANCE TO COMMON PATH OF TRAVEL a 75'-0' PER EXISTING FRAMED WALL OR FURRING TO REMAIN TABLE 1014.9 W/O FIRE SPRINKLERS [OKI - -- - SALVAGE FIXTURES AS DIRECTED BY OWNER. 0 CORNER GUARD EXISTING LOAD BEARING MASORNY WALL TO REMAIN OREMOVE EXISTING CASEWORK. SALVAGE AS DIRECTED BY OWNER. 2. OVERALL EXIT TRAVEL DISTANCE c 200'-0' FOR (B) OCC. WITHOUT EXISTING STRUCTURAL COLUMN TO REMAIN SPRINKLERS PER TABLE 1016.2 IOKI OFOR PLUMBING AND ELECTRICAL CONNECTION NOTE THAT THERE IS SPACED BELOW NEW WALL FRAMING OR 1NFILL SEE WALL TAGS 6420 THE REMODELED SPACE FOR ACCESS FOR PLUMBING AND ELECTRICAL NEW WALL FURRING SEE WALL TAGS g• 111 EXIT PROVIDED AND {1) ARE REQUIRED PER 1015.1. SINCE WE HAVE E STEREO LESS THAN 50 OCCUPANTS LOAD. (OKI ITECT 0, REMOVE EXISTING FLOORING. VINYL RUBBER BASE. TYPICAL WITHIN EXIST. SPACE. 0 DOOR TAG SEE SHEET A-2.9 1101 1 ROOM NUMBER SEE SHEET A-2.9 PETER WASHINGTCH O SEE MECH. DWGS. FOR DEMOLISHED DUCTING AND PLUMBING FIXTURES. TIP. 4 WALL TAG NUMBER SEE SHEET A-2.9 STAlE @ REMOVE DIRECTED B ALL EXY OWTINISGNER. TYP. FE ACP GRID. CEILING PANELS AND LIGHT FIXTURES. SALVAGE 2A1OBC FIRE EXTINGUISHER IN CABINET AS O N16.0CATED AND OR REMOVE/MODIFY ALL FIRE ALARM HORNS AND STROBES. Ima,j DIRECTIONAL EMERGENCY EXIT SIGN HARDWIRE ISLAND HOSPITAL ELECTRICAL DRAWINGS TIP. W/ BATTERY BACKUP COORDINATE ALL MECHANICAL/ELECTRICAL ROUGH IN PRIOR TO ANY COVER OF PRIMARY CARE CLINIC COMBINATION EXIT SIGN/EMERGENCY LIGHTING W/ EXPANSION AND IMPROVEMENT 10 WALLS AND OR CEILING CAVITIES. COORDINATE ALL ROUGH IN MECHANICAL BATTERY BACKUP HARDWARE AND PLUMBING REQUIREMENTS FOR EQUIPMENT WITH TENANT. TYP. OB GYN CLINIC EMERGENCY LIGHTING W/ BATTERY BACKUP HARDWARE 1, -REMOVE EXISTING WINDOW AND FRAME (�+7 �y{TnC+t�t i 12 REMOVE EXISTING DOOR AND FRAME. .,-'i ISLAND HOSPITAL tTALr 19 REMOVE DRYWALL A9 REQ'D. AT EXIST. EXTERIOR FURRED WALLS TO ALLOW FOR NEW ELECTRICAL DEVICES AND CONNECTION TO NEW RELOCATED ELECTRICAL PANEL CONTACT: MIKE MCKENNA r-• .. x N PATCLL IN WALL AS REQH/FI'D AT FORMER -- -r- ----.-.-� 4,----- - ` 1 SHAFT LOCATION I ,_ JJ � /� II I ��I ✓ ii i t; \\._ 1.u :.-., 0 6 ..LIKE'"• vi SR. 7IMECI NUMB :® f \FILLIW ��- - - _ r I I I j ® 1� I I 1 ,,, vi I I I j / I -J I •I * 4'-0. 9'-0 , 1 1 ❑- DOG ORS HALL Fe __J - L _J Y; X / / 12 EXAM-5 114 19 101 C 9 1� REVISIONS: r 112 ®2/2O/18 PERMIT/BID SET t I I to I ftr-------7 I I r o aI .........., • ,, .„ ` - . Lk_ EXAM-1 2 f--'I © T v sV/ T— 102 � I II - / I Q w. i iri vi 0 E I ��j Iini ���' Q EXAM-4 a I 0 v. r ` 110 0 I I�� p .iJ 0 0 I O ,Q s ii 2 — f �' I I ip NEW 0' CONC. SLAB I .•. O O 0 -..... I I T y I ` I L �L/J I I FOR CONDENSOR UNIT ' �_---�,--r- J SLOPE AWAY FROM V1 O i' 1D - I I f 0 ; —— — — I I BUILDING TYP. I 1 MA'S/RN'S rA L L- J THICKEND EDGE 1 L..........»» MEM 12 DEEP ® PERIMETER '1 ----) j - (2 ® - a 0 0 ✓I O� f �° m 1 EXAM-2 2 �': I I 0© J -==1 I EXAM-3 I� 109 SHEET TITLE: �___� 0 // /I 100 — -_I 1 �I T 2 SPILL 1N 0 I I i DOOR OPENING DEMOLITION FLOOR PLAN r,iI I 0 4 _ �/ ® HALL 7 �_ A-1' I I I © I i' I A 102 ® 9 `r" PROPOSED FLOOR PLAN „IIQ J„.-.., _, _____ 0 0 __,--,-_—_..7_7_ _ © p ® ;,1 I 0 1 V COLUMN V - - J t • a F r T—` 6 ' STUDS :: r Y III /(r111 I it ,A -_ _ I. \ I / I ,\\ 11 2 II / I mom\ II /� 1 --�-, O O O VESTIBULE II I I l ° I •�_ 11 g II / �c ill __J SCALE III L-�/ © II O LEisti 1 ® \Oi ELec�L I ® = ® t,� III ® �Ovi ULTRASOUND l T ® _ O L PANEL I I I 0 O 14EAN _ �' ASSTHRU 106 1 J Yi 5,4 1 i___J I �' _ • DIRTY a 108 V 01 i-----� O 1 7/8 EXAM-60 ®r r}t Y. II I 4 3 4 I R.R. t I A� I II- PJC I II I I 9* 0__ Q --_ / INSTALL BLOCKING I �+�, 107 / I 0 I PROJECT ARCHITECT, r 1 r , r IN CEILING ABOVE ACP J / 1O- I T 0 0 ® a L° �.- -- ® --- i.3 --T 1 TEL FOR CEILING MTD. 0 L — — I PJC L J MONITOR Il ° I I ( i _ = 1..1 1..I . DRAWN BY: »...._ e!!!l7lZ7././.................... .-.717��( 7 f 171771I/.T..r`% c.tt.lZf7!%7 r ..r.c..1.l�fll.T(f 1..71 ::::•.:•:::• -:-:-.-..._m.:v.»......... .l..<.,l..f.�l.,�i.. .._._._ ,1.,7.� .r...7..c..�.f..f.:l..l..l.��.�// :r..l..l..r.: ,ll%%::: .... ..;:.!'.l..f..l..t..t..t.`.�.tl..f.l./:F;:--:r.:l..l.12.71..11.l1.C� ....::.:.....:.�:�:<:.�;(.1.7>:?,17..Z.Z�_ ���;l>f7�l.1..:':- �.l..e�.::.�::::::::::.-::::::::::.�:::i:ii �. - PJC -7 I © CHECKED BY: X JANUARY 12. 2018 DATE 18-201.DWG COMPUTER FILE NAME A ,. 2 - DEMO/EXISTING PLAN /\± \,..,_,./ 1/4'4-0' 4 OPf2N,PROPOS . D FLOOR CLAN LOPYftIDHT 1010 CARLET7 ARCHIT2CT9.P.S. 1/4•�r-o• " CITY OF ANACORT '/ r� r DEMO LEGEND: i . `, " a.',` PLANNING & NA O G DEPT. EXISTING FRAMED WALL OR WALL FURRING TO REMAIN �, gppROVED MAYu 3• m SS/1/2/2 EXISTING LOAD BEARING MASONRY WALL TO REMAIN FLOOR PLAN KEY NOTES: FLOOR PLAN NOTES: °Ivor ;' EXISTING COLUMN TO REMAIN O NEW CASEWORK WITH UPPERS SEE CASEWORK ELEVATIONS, 1. COORDINATE WITH HOSPITAL STAFF ON ITEMS TO BE SALVAGED AND SAVED PRIOR TO REMOVAL. PERMIT#: 02 jHAiti"CON, 2. NOTIFY ARCHITECT IMMEDIATELY IF CONDITIONS VARY FROM THOSE SHOWN ADDRESS: 3 / /�IT/�1 EXISTING WALL AND OR ITEMS TO BE REMOVED it NEW CUBICLE CURTAIN TRACK AND CURTAIN. PROVIDE AND INSTALL STEEL STUD OR IF UNFORSEEN ISSUES ARE DISCOVERED. MIT RELOCATED SALVAGED DOOR AND FRAME/HARDWARE LIGHT GAUGE SUPPORT FRAMING ABOVE ACP AS REQUIRED TO SUPPORT TRACK_ 3. PROVIDE BLOCKING IN WALL FOR ALL F.O.I.O. INCLUDING: SOAP DISPENSERS, PAPER TOWEL DISP. APPROVED eV: VED PLANS ® SEE DOOR SCHEDULE SHEET A-2.3 Q NEW SINK WITH NEW FAUCET. SEE MECHANICAL DRAWINGS. SEAT COVER DISP.• TV. CEILING MOUNT ECT. CONTRACTOR TO FURNISH AND INSTALL ALL GRAB BARS. ELpINSPECTION• APP SUBJECT ;AATITFIARC HIT ECTS P.S. SHALL NOT BE ALTERED WITHOUT A architecture,planning,interior design DEMOLITION KEY NOTES: 4, NEW TOILET AND LAV. MATCH EXIST. SEE MECHANICAL DRAWINGS. 116 EAST FIR STREET EQUIPMENT/FURNITURE F,O.I.O. SUITE A REMOVE EXISTING NON-BEARING WALLS AS NOTED. MOUNT VERNON, WA. 98273 GRAB BAR F.C.I.C.. PROVIDE BLOCKING IN WALL AS REQ'D. FLOOR PLAN LEGEND: EXIT PLAN NOTES: REMOVE EXISTING DOORS/FRAMES. SALVAGE FOR RELOCATION/REUSE Phone: (3601 424-0394 0 NEW CASEWORK SEE CASEWORK ELEVATIONS. 1. TRAVEL DISTANCE TO COMMON PATH OF TRAVEL < 75'-0' PER Fax I360 424-5726 REMOVE EXISTING PLUMBING FIXTURES. CAP EXIST. PLUMB. FOR FUTURE USE EXISTING FRAMED WALL OR FURRING TO REMAIN TABLE 1014.3 W/0 FIRE SPRINKLERS (OKI SALVAGE FIXTURES AS DIRECTED BY OWNER. 0 CORNER GUARD 1TITZ! EXISTING LOAD BEARING MASORNY WALL TO REMAIN 4, REMOVE EXISTING CASEWORK. SALVAGE AS DIRECTED BY OWNER. 2. OVERALL EXIT TRAVEL DISTANCE 1. 200'-0' FOR (B) OCC. WITHOUT 2 EXISTING STRUCTURAL COLUMN TO REMAIN SPRINKLERS PER TABLE 1016.2 (OK) NEW WALL FRAMING OR INFILL SEE WALL TAGS 8429 4, FOR PLUMBING AND ELECTRICAL CONNECTION NOTE THAT THERE IS SPACED BELOW T•.- NEW WALL FURRING SEE WALL TAGS 3. H) EXIT PROVIDED AND 111 ARE REQUIRED PER 1015.1. SINCE WE HAVE �STERED THE REMODELED SPACE FOR ACCESS FOR PLUMBING AND ELECTRICAL LESS THAN 50 OCCUPANTS LOAD. (OKI w ` ITECT 4, REMOVE EXISTING FLOORING. VINYL RUBBER BASE. TYPICAL WITHIN EXIST. SPACE. 4, DOOR TAG SEE SHEET A-2.3 - 1,4� 101 ROOM NUMBER SEE SHEET A-2.3 PR .'.'a STATE O''WASHINGTON 4, SEE MECH. DWGS. FOR DEMOLISHED DUCTING AND PLUMBING FIXTURES. TYP. y WALL TAG NUMBER SEE SHEET A-2.3 0REMOVE ALL EXISTING ACP GRID. CEILING PANELS AND LIGHT FIXTURES. SALVAGE n 2A1OBC FIRE EXTINGUISHER IN CABINET AS DIRECTED BY OWNER. TYP. RELOCATED AND OR REMOVE/MODIFY ALL FIRE ALARM HORNS AND STROBES. ® DIRECTIONAL EMERGENCY EXIT SIGN HARDWIRE ISLAND HOSPITAL SEE ELECTRICAL DRAWINGS TYP. W/ BATTERY BACKUP PRIMARY CARE CLINIC COORDINATE ALL MECHAN%CAL/ELECTRICAL ROUGH IN PRIOR TO ANY COVER OF ® COMBINATION EXIT SIGN/EMERGENCY LIGHTING W/ EXPANSION AND IMPROVEMENTS 0 WALLS AND OR CEILING CAVITIES. COORDINATE ALL ROUGH IN MECHANICAL 1--P BATTERY BACKUP HARDWARE OB GYN CLINIC AND PLUMBING REQUIREMENTS FOR EQUIPMENT WITH TENANT. TYP. EMERGENCY LIGHTING W/ BATTERY BACKUP HARDWARE REMOVE EXISTING WINDOW AND FRAME 0 REMOVE EXISTING DOOR AND FRAME. REMOVE DRYWALL AS REQ'D. AT EXIST. EXTERIOR FURRED WALLS TO ALLOW FOR NEW ELECTRICAL DEVICES AND CONNECTION TO NEW RELOCATED ELECTRICAL PANEL CONTACT: MIKE MCKENNA i i I PATCH/FILL IN WALL AS REQ'D AT FORMER I I _ SHAFT LOCATION .-...... ro .—_L� -I �,T� r,��_ I n A r_ — — _ — �, — -- FILL IN r \`L�— J� / I WINDOW OPENING -t I ExI r. I Ili 0 0 O // II ® ` � �/� O COL MN,. a 0 , j /T1'Tc� �_- - � u — S V �� _ I I � 1 FT+ — c 1 I Nx� TTTTl, STAR. I © 1 EXAM-5 1 I r EXIT K U�tCT NUMP�CR: I I I -� l_ �A\ I- - -1 I o '11 ® 112 5-0 REVISIONS: Li I I j , / �� p, 13 i� �� -- J I � 104 101 Q I�� - - - � \ , 2/20/18 PERMIT/BID SET — � 'l �� I �1 — EXAM-1 �,�. 2 i I 0 0 r �� �� I INSTALL BLOCKING — L 102 © 3/9/18 OWNER REVISIONS U�(_ 1 I 4 IN WALL FOR MTD — 1 I LJ l / I I I — _ A_2.3 VIDEO MONITOR 1 III L — I r- �-- _ — _ 1 T i I — © 4/11/18 DOH CORRECTIONS Iv T I0 I 1 I I h �11 / O / EXAM-4,„©� 0 o\ ExdsT. O II � ��, _ I �� G - -_ i( 4, 0 � o-- ( I 0 ' ° u - — — I ia NEW 8' CONC. SLAB { ""." 1 I EP 4 ll /' ( / J f FOR CONDENSOR UNIT 2' 3� L _ / I SHIGPE AWAY CKEND EDGE FROM © 3n L - - - _ J IBUILDING TYP. f 1 MA'S/RN'S A-2.3 2 I 9) • ;:-/: .f� J ,/r 12' DEEP o PERIMETER r _ I — - -.. ...- 411 // y T } © 0 O — m D EXAM-2 © ' /I I I 7 0 I c = _ ' EXAM-3 X 103 0 /, FILL %N SHEET TITLE: �2 I �L J it © pp — �2 -I 2 + 6 - - - R1 0 / �� — 1 Icy DOOR OPENING DEMOLITION FLOOR PLAN ;[ I HALL m -\--- I I Q — 102 ® © �� PROPOSED FLOOR PLAN _ r-3f exdsT. II �/ © © © 1 /- COLUMN 1 S.S. SPECIMEN V\ l 2-61' 4-p• 3'-6' /PASSTHRU = ' L_1_J .. -.. .. . . - - - - �( - - -, -- - � 4 0 1 r 7 — __ _ STUDS: Pik 1 - - - 1 � ; P n \ II II / II ��� J n O G, ` C VESTIBULE III 11 /Fo� \ II r , � ✓ ✓ .�' SCALE • 10 `° 2 II III i t II II i III v LL_ ,! .� pie 1 � ,� - Iu i �� � °� u�� / kl tIII g A-2.3 — I -� ELEC IIITh- ,1CLEAN4 , 1 \ 0 �� �� _ © DOCTORS LA I :t' .� O•_,A / .v7N t4'-d ,. I " - - - --I 114 ® 6' 0 I I 1 j 0 w O - •a +, 3 I Ro I ULTRAS�UNC® PJC �_ Li_ I I © O — g D tO I 0 10 PROJECT ARCHITECT: �� �J Lo-I+J ....-...-... ,. I ., V �_ ._ DRAWN BY: ...-. 1 --- - . , / // , I -._ ,� r r � r i -;>-- - i �, T/ I.;TT11...- T,-T TTITLIT 7ZLT�.1�IITLT�-I_TLTTTl_ T,:.11TTi ;-T_ TI7I-T/ 1Lll., T �T"TIT�LcI TTlT �T. T/L/ Ti/--ZI/lltrlTZTTT�T-LTTT�T.-T 1TTT/T.T. 11_�T l T�lTTT, /.._T1TTTI_I....TTTT�T_, TTTTIT % T//TTT llTl _ PJC ry © O ® CHECKED BY: 48'-7i , JANUARY 12, 2018 X DATE /' 18-201.DWG COMPUTER FILE NAME AC ' ____. 2 , ti 1- � EVO / EXISTI \ G PLA \ 1 ' 2 P � 0P05ED FLOOR PLA \ 4IP j 1/9,'°1 -V' 2018 CARLETTI ARCHITECTS. COPYRIGHT ��5 .44 '` a , CARLETTI ARCHITECTS PRS, architecture,planning,interior design 116 EAST FIR STREET SUITE A MOUNT VERNON, WA. 98273 PROPOSED CEILNG LEGEND: Phone: (360! 424-0394 Fax: 360 424-5726 ® NEW 2X2 LED LIGHT FIXTURE SEE ELECTRICAL DWGS. M NEW 2X4 LED LIGHT FIXTURE SEE ELECTRICAL DWGS. AI 6429 pSTERED 0NEW OCCUPANCY SENSOR SEE ELECTRICAL DWGS. ITECT 11 _ NEW UNDER CABINET SEE ELECTRICAL DWGS. _ _ PETER 1 -'•+ o NEW LED CAN LIGHT SEE ELECTRICAL DWGS. STATE �wasHiNGTON o NEW LED VANITY LIGHT/WALL MTD. SEE ELECTRICAL DWGS. DEMO CEILING LEGEND: 11' NEW DIFFUSER SUPPLY GRILLE SEE MECHANICAL DWGS. El NEW RETURN AIR GRILLE SEE MECHANICAL DWGS. ISLAND HOSPITAL EXISTING LIGHT FIXTURE SALVAGE AS DIRECTED PRIMARY CARE CLINIC EXISTING RETURN AIR/DIFUUSER GRILLE REMOVE oe NEW SPEAKER SEE ELECTRICAL DWGS. CONNECT TO SYSTEM EXPANSION AND IMPROVEMENT OB GYN CLINIC EXISTING CAN LIGHT REMOVE SALVAGE AS DIRECTED Y REMOVE ALL EXISTING SUSPENDED CEILING GRID AND TILES TYP. ENTIRE SPACE • CONTACT: MIKE MCKENNA / I , Eli II;7/ II— _ u — —— — — 1 j/ , . 18 2 01 ��� r / /r°z?7-l� l77.777r -- 1— ��- - 1 Lc N I_,€ �. — k� ���_ _ — — — 1 NKUJCG I NUME3CR: I I ° I I L—, 1 �� oc o / I I j ' II I REVISIONS: �I I 1 �/ �� u I � _- I �T � � s� Q �� ' � 2/20/18 PERMIT/BID SET I I T ! 1 L I I I il oc I —L _ b\N S\s, © 3/9/18 OWNER REVISIONS f j J ,—/ j j -- I � 11 oc � _� ram _ -- _ J 1 ( 7 / 4/11/18 DOH CORRECTIONS FA 0 Ell - r ,f I I P� ' - - ` - - - - le 7 1 J) PV u I I I oC _ 114 L • 0 C pL- J , 1 I rl� I I �� ��tip � _" —I I—T = r„ x7 oc SHEET TITLE: NM f / I —I I I = = = = i x l6 / oc7 DEMOLITION CEILING PLAN IIM�) _ --- / A PROPOSED CEILING PLAN ✓IE,j :, I Pr 1 M � )—l.J �r - -=� - - - I h 1�� ���, li - I ;.x:n T _ _ -- - 1 n \ it II I I III 111 I II /�oin II II , r _ _ _ _ {� 1111 I II / III ` � � �� Ih Iu_� I �� y u _- IIIllAP` , N. h, � ELEC.� I fa I I I I✓ �� ` PANEL. 1 ' 1 H L — ...... - - i 0T T 1 - - - - -I Ea �� 1. `� I — 1 v II I - 1 PJC vt, I I 1 1J 1 I _— N PROJECT ARCHITECT: ilivI LL -•,... I • \ Fon 1- �,, 1 1 \• \ L I. I- r-e -) TEL ' — — i DRAWN BY: J __ / : / l/L7 =Z.- r7/Z /7/7/f�/ZI11ZT/ l< // /_ • k - L rlL///7- . /LII/I Zl7Il/7 ITT721 1,T//Z/7. IIT77I 7 //1TTTIZ T'I/77 7 T T17T 7, TII�l1i l_ 7 ZIT/ l T77777-777 77///, l /-11IT 777TI_4 P J C CHECKED BY: © 3"81 ® n'xs JANUARY 12, 2018 DATE 18-201.DWG COMPUTER FILE NAME 1 D E M 0 / E " 15 T I \ G 0 E 1 L 1 \ G F L A \ P R O P O S E D CEILING P L A 1/4'=1'-0'� 1/4'4-Q' COPYRIGHT 2018 CARLETTI ARCHITECTS. P.B. DOOR SCHEDULE :1 r/7e ' NO. SIZE DOOR LEAF FRAME CLOSER RATING PANIC HARDWARE NOTES TYPE MAT'L. FIN. MAT'L. FIN. GROUP 1 3'-0' X 6'-8' C WD CLR HMF PNT YES - _ - - NEW DOOR AND FRAME REUSE EXISTING LEVER HARDWARE FROM EXISTING ENTRY DOOR O49 2 3'-O' X 6'-8' A WD CLR HMF PNT - - - _ - REUSE EXISTING DOOR AND FRAME EXIST. LEVER HANDLE HARDWARE 9c 3 3'-0' X 6'-8' A WD CLR HMF PNT - - - - REUSE EXISTING DOOR AND FRAME AND EXIST. LEVER HARDWARE DOOR TYPES Gy 4 3'-0' X 6'-8' A WD CLR HMF PNT - _ - - - NEW DOOR AND FRAME AND NEW LEVER HARDWARE MATCH EXIST. CARLETTI ARCHITECT OP•' 5 3'-0' X 6'-8' B WD CLR HMF PNT yes - - - REUSE EXISTING DOOR AND FRAME AND HARDWARE ADD A CLOSER AND S.S. KICKPLATES architecture,planning,interior design :16 00`.),( '-8' A WD CLR HMF PNT YES - - - I' ' EXISTING DOOR AND FRAME AND EXISTING HARDWARE LEVER HANDLE PRIVACY LOCK 7 3'-0' X 6'-8' A WD CLR HMF PNT - - - - &REUSE 'OOR AND FRAME AND NEW LEVER HARDWARE MATCH EXIST. T 116 EAST FIR STREET ' 8 S'-O' X 8'-8' A WD CLR NEW PO KET DOOR WITH BARRIER FREE HARDWARE T SUITE A , G 9'-0' X 6' A WD CLR HMF PNT NEW 'OOR AND FRAME AND NEW LEVER HARDWARE MATCH EXIST. _' MOUNT VERNON, WA. 98273 3'-0' 6'-8' A WD CLR HMF PNT - - - - TING DOOR AND FRAME AND EXIST. LEVER HARDWARE TO REMAIN Phone: 360 424 0394 11 3'-O' X 6'-8' A WD CLR HMF PNT EXISTING DOOR AND FRAME AND EXIST. LEVER HARDWARE TO REMAIN Fax: 1360) 424-5726 r" "-0' X 6'-8' A WD CLR HMF PNT - - - _ - REUSE EXISTING DOOR AND FRAME NEW LEVER HANDLE WITH KEYED LOCK HARDWARE 13 3'-" X 6'-8' A WD CLR - - - , - - - REUSE EXISTING DOOR AND FRAME NEW LEVER HANDLE HARDWARE MATCH EXIST. TYPE A TYPE B TYPE C ` 14 3'-0' X 6'-8' A WD CLR HMF PNT - - - - NEW DOOR AND FRAME AND NEW LEVER HARDWARE WITH LOCKSEST OCCUPIED MATCH EXIST. : T•TEMP . L NOTES: illmi EX D.' 'S SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. f 6429 2. ALL GLAZING WITHIN A 24 INCH ARC OF EITHER EDGE OF DOORS AND WITHIN 18 INCHES OF FLOORS SHALL BE SAFTY GLAZING AS eSTERED REQUIRED BY IBC SECTION 2406.3. ALL SUCH GLAZING SHALL HAVE PERMANENT IDENTIFICATION SAFTY GLAZING STAMP. ITECT 3. DOORS SHALL HAVE LEVER HARDWARE WHICH WILL PERMIT OPERATION BY WRIST OR ARM PRESSURE — 4. DOOR SPECIES TO MATCH EXISTING MAPLE. DOORS TO BE 1-3/4' SOLID CORE. � P" Di' J. Vii -• FINISH SCHEDULE I _ '' STA OF WASHI` TON ROOM ROOM FLOOR BASE NORTH WALL SOUTH WALL EAST WALL WEST WALL CEILING NOTES: MA'S/RN'S _.__,._ - 113 NUMB. NAME MAT'L FIN. NO. MAT'L FIN. NO. MAIL FIN. NO. MAT'L FIN. NO. MAT'L FIN. MAT'L FIN. MAT'L FIN. NO. HGT. 100 _ _ 101 HALL LVT FF LVT-1 VRB FF VRB-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 7'-8' ISLAND HOSPITAL 102 EXAM-1 SV FF SV-1 VRB FF VRB-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT ' P-1 ACP ' FF ACP-1 '7'-8' PRIMARY CARE CLINIC 103 EXAM-2 SV FF SV-1 VRB FF VRB-1 GWB PNT P-1 GWB PNT P-1 - GWB PNT P-1 GWB - PNT P-1 ACP - FF -ACP-1 7'-8' EXPANSION AND IMPROVEMEN 104 EXAM-6 SV FF SV-1 VRB FF VRB-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 7'-8' PENCIL OB GYN CLINIC 105 CLEAN SV FF SV-1 SV FF SV-1 - GWB . PNT PAGWB ' PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 7'-8' COVED SHEET VINYL BASE DRAWER 106 DIRTY SV FF SV-1 SV FF by-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT PNT-1 7-8' COVED SHEET VINYL BASE ' __ 107 RESTROOM TILE FF 'T-1 TILE . FF T-2 TILE/GWB PNT P-1 TILE/GWE PNT P-1 TILE/GWB PNT P-1 TILE/GWB PNT P-1 GWB PNT PNT-1 7'-8' TILE TO 72' A.F.F. GWB PAINTED ABOVE SUPPORTS 11 O' I - _ - \-m_ ram, 108 ULTRASOUND SV FF SV-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 7-8' -ir\ — F.E. � \ ISL H©SP 109 EXAM-3 SV FF SV-1 VRB FF VRB-2 GWB PNT P-1 ' GWB PNT ?-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 7-8' —_�' _ CONTACT: 110 EXAM-4 SV FF SV-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT F-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 7-8' '� �������—��i MIKE MCKENNA 111 STOR. SV FF SV-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT f''-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 T-8' a a o r 112 EXAM-5 SV FF SV-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 7'-8' 113 MA'S/RN'S LVT FF LVT-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 7'-8' --1-- \ \ — 1 \ ---. \ 114 DOCTORS CPT FF CPT-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 7-8' CARPET TILES ® MAS (-1 M : ' ' 14 MA'S 13 RN'S 1/4' • 1'-O' 1/4' • l'-O' \ 1/4' - 1-O' 1/4' • 1'-O' INTERIOR MATERIALS LEGEND ABBREVIATION DESCRIPTION it SIZE MANUFACTURER: STYLE: COLOR: NOTES: FLOOR/BASE: LVT LUXURY VINYL TILE 1 MANNINGTON 1 SV SHEET VINYL 1 ROLLED GOOD - - MANUFACTURER'S STD. SELECT - — SV COVED SHEET VINYL 2 4' H - - MANUFACTURERS STD. SELECT • Lw "-S i CPT CARPET TILES 1 24'X24' - MANUFACTURER'S STD. SELECT - DOCTORS 18-201 VRB VINYL RUBBER BASE 1 4' H JOHNSONITE MATCH EXISTING MITER ALL CORNERS NKUJC(; I NUMBtR: VRB VINYL RUBBER BASE 2 4' H JOHNSONITE - MATCH EXISTING MATCH EXISTING 114 ® vip TILE PORCELAIN TILE FLOORING 1 121X12' TILE - - MATCH EXISTING MATCH EXISTING TILE PORCELAIN TILE WALL 2 12712' TILE MATCH EXISTING MATCH EXISTING . REVISIONS: GROUT EPDXY GROUT 1 - MARPEI - MATCH EXISTING MATCH EXISTING SIM TO ELEV. 11 / 2/20/18 PERMITlBID SET PAINT: PNT PAINT 1 - SHERWIN WILLIAMS EGGSHELL - MATCH EXISTING L I .-._.— © © 3/9/18 OWNER REVISIONS PNT PAINT 2 - SHERWIN WILLIAMS EGGSHELL - MATCH EXISTING �, — CASEWORK: J — © 4/11/18 DOH CORRECTION; P-LAM PLASTIC LAMINATE 1 SHEET GOOD FORMICA STANDARD - COUNTERTOPS P-LAM PLASTIC LAMINATE 2 SHEET GOOD FORMICA STANDARD - CASEWORK FACES DOORS/DRAWERS 1 CEILING: ACP I ACOUSTICAL CEILING PANEL I 1 I 2' X 4' I ARMSTRONG I FINE FISSURED HIGH NRC 1728 I WHITE I SQUARE LAY-IN W/ 15/16' SUSPENSION SYSTEM COLOR WHITE X 74' X Et" cy ,; ,, PENCIL PENCIL SUPPORT DRAWER DRAWER o DIVIDER P.LAM B.S. 8 cI BEYOND COUNTERTOP FE M®M FE __ SH T TITLE: ®® ®®, o m SUPPORT ®0 �' NineilMI DIVIDER DO R SCHEDULE BEYOND FI ISH SCHEDULE EXAM 5 C DOCTORS , 11 DOCTORS NISHES A ° 1/4' • 1'-0' 1/4' - r-o' 1/4' • 1 -0' INTERIOR ELEVATIONS fral T f ----/- EXAM-4 EXAM-1 EXAM-2 EXAM-3 AM 0ULTRASOUND o \� I CLEAN DIRTY 103 toe ROCEDURE I 105 106 102 109 104 ____...-- SHELVES W/ PJC BRACKET SUPPORTS PROJECT ARCHITECT: AS REQ.D i I- --- — 1 \ PJC DRAWN BY. 77 ^-. , r .....-._. N ,, .. ,„c` . `. At, ,w. 1 PJC , . n r, \, t. I ‘ , , : 1j — —_ I AM FRnM' CHECKED BY, o P.LAM B.S. & COUNTER TO @TM. SELVES TO BTM. N COUNTERTOP TY UPPERS JANUARY 12, 2018 SINK --- DATE "\ ,f a o 'Br- I I 4�� , , 18-201.DWG k e� I , COMPUTER FILE NAME Imo , , v , ' NZ \Z\ . I — li_ _ IL r1� XAN -1 c EXAM-2 C3)EXAM-3 4 EXAM-4 ..-, ASOUN / 6) EXAM - 6 8 CLEA \ DIRTYCOPYRIGHT 2018 CARLGTTI ARCHITGCTS. P.S. i 1/4' • 1'-O' 1/4' • 1'-0' 1/4' • 1'-0' 1/4' • 1'-0' 1/4' 1'-0' 1/4' • 1'-O' SCLEAN 1/4' • 1'-O' 1/4' • 1'-0' 1/4' • 1-0' 17 8 PROJECT TEAM PROJECT GENERAL NOTESDRAWING I \ DUX j j DATA 1 IN GENERAL, PLAN DIMENSIONS SHOWN ARE TO FACE OF STUD OR FACE OF CONCRETE. UNLESS OTHERWISE NOTED. DO NOT SCALE THESE `� o. OWNER PROPERTY INFORMATION DRAWINGS. USE CALCULATED DIMENSIONS ONLY. VERIFY ALL DIMENSIONS ARCHITECTURAL 'ECTURAL ISLAND HOSPITAL ISLAND HOSPITAL - ULTRASOUND/PAIN RECOVERY REMODEL DATUM. AND LEVELS PRIOR TO CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPENCIES. A-0.0 COVER SHEET CARLETTI ARCHITECTS P.S, 1211 24TH STREET A-2.0 OVERALL FLOOR PLAN PROPERTY ADDRESS 1211 24TF REST 2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO architecture,planning,interior design ANACORTES. WA 28221 ANAL ES. WA 08221 INITIATING THE WORK. NOTIFY ARCHITECT OF ANY DISCREPANCIES. A-2.1 DEMOLITION FLOOR PLAN/PROPOSED FLOOR PLAN PHONE: 360-299-1395 A-2.2 DEMOLTION RELF. CEILING PLAN/PROPOSED REFLECTED CLG. PLAN EMAIL: mmckennaoielandhoepital.org BUILDING CODE 2015 IBC 1Q 3. ALL WORK SHALL COMPLY WITH THE 2015 IBC. IFC, UPC, IMC AS AMENDED BY WASH. A-2.3 SCHEDULES/INTERIOR ELEVATIONS 116 EAST FIR STREET CONTACT: MIKE McKENNA STATE. PROJECT SHALL ALSO COMPLY WITH THE 2016 NREC AND THE VIACQ CODES. A-6.0 DETAILS SUITE A ENERGY CODE 2016 WASHINGTON STATE NREC PROJECT SHALL ALSO COMPLY W/ JURISDICTIONAL CODE AMENDMENTS BY THE LOCAL FIRE SPRINKLERS NONE EXISTING NOT REQUIRED AGENCY. CONTRACTOR IS RESPONSIBLE FOR OBTAINING NECESSARY PERMITS & MOUNT VERNON, WA. 98273 ARCHITECT INSPECTIONS TO COMPLETE THE WORK. CONTRACTOR TO HAVE CURRENT VALID CITY MECHANICAL FIRE ALARM NONE EXISTING NOT REQUIRED OR COUNTY BUSINESS LICENSE PRIOR TO ISSUANCE OF PERMIT, WHEN REQUIRED BY LAW. M-1.0 COVER SHEET Phone: 360 424-0394 CARLETTI ARCHITECTS, P.S. M-1.1 SCHEDULES HVAC Fax: 360 424-5726 116 E. FIR ST. SUITE A 4. ERRORS. OMISSIONS. AND DISCREPANCIES, IF ANY. SHALL BE REFERRED M-1.2 SCHEDULES PLUMBING & PIPING MOUNT VERNON. WA 08273 ZONING R4B --NRKSIDENTI ITY TWO (B) TO THE ARCHITECT IMMEDIATELY FOR DIRECTION OF HOW TO PROCEED. M-1.3 ENERGY CODE LOADS PHONE: (360) 424-0304 5. VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THE CONTRACT BY M-2.0 FLOOR PLAN PLUMBING/PIPING FAX: (360) 424-5726 PARCEL NO.: P116343 OTHERS PROVIDE ALL BLOCK-OUTS. BLOCKING, BACKING AND JACKS REQUIRED FOR M-3.0 FLOOR PLAN HVAC EMAIL: peterocarlettiarchitecte.com DUCTS, PIPES, CONDUITS, EQUIPMENT. FIXTURES, AND CABINETS. VERIFY SIZE AND M-4.0 DETAILS 642e CONTACT: PETER CARLETTI 6. LOCATION. DO NOT SIGNIFICANTLY VARY OR MODIFY THE WORK SHOWN. EXCEPT STEREO BUILDING CODE DATAUPON WRITTEN INSTRUCTIONS OF THE ARCHITECT. ELECTRICAL ITECT MECHANICAL ENGINEER 7. VERIFY LOCATION OF ALL EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO: SEWER. SEPTIC. WATER. GAS. POWER, AND TELEPHONE. CAP. MARK AND PROTECT. E-0.0 ELECTRICAL COVER SHEET. PANEL SCHEDULES pE1. HARRIS GROUP, INC. rit E-2.0 OVERALL ELECTRICAL FLOOR PLAN STATE WASHINGTON 20201 CEDAR VALLEY RD, STE 120 OCCUPANCY TYPE: I-2; NO CHANGE 8. DETAILS ARE INTENDED TO SHOW THE INTENT OF THE DESIGN. MINOR MODIFICATION E-2.1 DEMO AND PROPOSED LIGHTING PLANS LYNNWOOD, WA 98036 MAY BE REQUIRED TO SUIT THE FIELD DIMENSIONS OR CONDITIONS AND SUCH E-2.2 DEMO AND PROPOSED POWER PLANS PHONE: 206.404.9512 CONSTRUCTION TYPE: II-B: NO CHANGE MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK OF THE CONTRACT. E-3.1 PARTIAL RISER DIAGRAM FAX: (425) 672-2084 REMODLED AREA SQUARE FOOTAGE: 488 S.F. 9. PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF ALL GOVERNING EMAIL: Richord.Hawkinaonoharriegroup.cam AUTHORITIES. AT RATED PARTITIONS, FLOORS. CEILINGS. AND ROOF CONTACT: RICHARD HAWKINSON A V I A T I 0 \ 5 LOCATIONS. ALL REQUIRED FIRE-RATED PARTITIONS SHALL BE DEFERRED SUBMITTALS CONTINUOUS FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE. NONE ISLAND HOSPITAL ELECTRICAL ENGINEER 10. THE CONTRACTOR SHALL CONSULT PLANS OF ALL TRADES. INCLUDING PRIMARY CARE CLINIC AWA ELECTRICAL CONSULTANTS, INC. ABV ABOVE JNT JOINT DESIGN-BUILD DOCUMENTS REQUIRED BY CONTRACT DOCUMENTS, TO VERIFY EXPANSION AND IMPROVEMENT 10015 36TH AVE. WEST. SUITE E AFF ABOVE FINISH FLOOR SIZE, WEIGHT, POWER. LOCATION AND OTHER REQUIREMENTS AND LOCATION LYNNWOOD, WA 98036 AC TILE ACOUSTICAL TILE LVL LEVEL OF THOSE ITEMS TO BE INSTALLED PRIOR TO COMMENCEMENT OF WORK. ' O B GYN CLINIC PHONE: (425) 775-1790 ACP ACOUSTICAL CEILING PANEL L LONG, LINE 11. NO BUILDING OR PORTION OF A BUILDING SHALL BE OCCUPIED OR USED FAX: (4251 774-0870 ACT ACTUAL LAV LAVATORY FOR STORAGE PRIOR TO THE ISSUANCE OF THE CERTIFICATE GWB, PAINT EMAIL: bradoawaelec.com OF OCCUPANCY. NO EXCEPTIONS. 3 XC48 MIRROR 18' VERT. - � HOSPITAL CONTACT: BRAD ADCOCK AL ALUMINUM LIN LINOLEUM F I �� ARCH ARCHITECTURAL LT LIGHT 12. SEPERATE PERMITS ARE REQUIRED FOR PLUMBING, MECH.. ELEC.. FIRE SPRINKLER. GRgqgg BAR r-. A TILE ASPHALT TILE FIRE ALARM SYSTEMS 6 SIGNAGE. PAPER TOWEL e���, L'.LC. AVG AVERAGE MAR MARBLE 13. ALL EXPOSED EXTERIOR SHEET METAL SHALL BE GALVANIZED, PRIMED AND PAINTED. DISP. F.O.I.O. GWB. PAINT CONTACT: MO MASONRY OPENING u 1 1/2'GRAB BAF MIKE MCKENNA 14. ALL WOOD IN CONTACT W/ CONCRETE SHALL BE PRESSURE TREATED. SOAP DISP. I F.C.LC. BFF BOTTOM FINISH FLOOR MFR MANUFACTURE PRESSURE TREATED WOOD SHALL BE USED FOR WOOD MEMBERS WHICH N M F.O.I.O. BLKG BLOCKING MATL MATERIAL FORM THE STRUCTURAL SUPPORT OF BALCONIES, DECKS, OR PORCHES ma. u TILE 72' A.F.F. BR BRICK MAX MAXIMUM ETC. WHEN SUCH MEMBERS ARE EXPOSED TO THE WEATHER. lT BOS BOTTOM OF STRUCTURE MECH MECHANICAL 15. SLOPE ALL DECKS, PATIOS, AND WALKWAYS AWAY FROM BUILDING • o TILE TO i , o TISSUE PAPER MTL METAL MINIMUM OF 1/8'/FT FOR POSITIVE DRAINAGE. TISSUE PAPER 72' A.F.F. s DISPENSER F.C. MIN MINIMUM DISPENSER F.C.1.C. CPT CARPET MUL MULLION 16. PROVIDE EXPANSION JOINTS IN ALL CONCR ABS AS REQ ED CLG CEILING TO PREVENT CRACKING. SAW CUT ALL SL SAS RECTO. ELEVATION ELEVATION CEM CEMENT 17. PROVIDE FIREBLOCKING, DRAFTSTOPS, AN FIRESTOPS IN ATTICS, OORS, NAT NATURAL AND WALL CAVITIES AS REQUIRED PER T IBC. rL CENTER LINE NOM NOMINAL \ LIN=I .�, S; 60' 6' CLEAR GWB. PAINT C TO C CENTER TO CENTER 18. ROOF DRAINS, AND OVERFLOW DRAINS SHA COMPLY W/ THE UP( 6 fBC. O. NA NOT APPLICABLE FLOW SPACE AND WALL CAVITIES AS REQUIRED PER THE C. 30 X 48 MIRROR < GWB. PAINT CT CERAMIC TILE A - 7 t ,r NIC NOT IN THIS CONTRACT 1 C.LC. CLO CLOSET 10. DRAWINGS INDICATE GENERAL AND TYPICAL DE S OF C NSTRUC ON. rr r PAPER TOWS NTS NOT TO SCALE !!� I - DISP. F.O.LO. � � TILE 72' A.F.F. - CW COLD WATER WHERE CONDITIONS ARE NOT SPECIFICALLY INDICAT T z 11 II N0, # NUMBER Ill SEAT COVER DISP. SYMBOLS COL COLUMN CONS CONCRETE SIMILARNSTR CHARACTER SHA O DUSEILS B ECT. SIMILAR DW YILS OFI. F.CI.C. CONSTRUCTION SHALL BE USED SUBJECT TO REVIEW BY THE ARCHITECT. im i SOAP DISP. OC ON CENTER 'o F.O.LO. 1 1/2' GRAB BAR CMU CONCRETE MASONRY UNIT OD OUTSIDE DIMENSION 20. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE MEANS, p ,Ili �,�� p C.I.C. 18-201 CONST CONSTRUCTION METHODS. TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. !� 1. c VNOJCC I NUMB <; /� CONT CONTINUOUS 0/ OVER 21. CONTRACTOR SHALL RETAIN ONE SET OF THE PLANS TO NOTE AND DOCUMENT ALL . o < - TILE 72' A.F.F. • ` OTS OPEN TO STRUCTURE I�� . ' NORTH ARROW COORD COORDINATE CHANGES DURING CONSTRUCTION. THE SET SHALL BE A PART OF THE CONTRACTOR'S 18' MIN. TO �. , LINE OF OVHD OVERHEAD CLOSE-OUT PACKAGE TO THE OWNER. SEE SPECIFICATION FOR CLOSE-OUT PACKAGE 18' MAX. CL MIN. 30' X 48' CLEAR : COR CORRIDOR SHOP DRAWINGS. PRODUCT LITERATURE. EQUIPMENT WARRANTEE MANUALS. TO ADJ. WALL 5'-0' FLOOR SPACE IS - REVISIONS: CFM CUBIC FEET PER MINUTE PNT PAINT AMIN. P L A\ CI GRID LINE 22. CONTACTOR SHALL PROVIDE SOLID BLOCKING. UNLESS NOTED OTHI`.RWISE AS REQUIREDELEVATION' ELEVATION 2/20/18 PERMIT/BID SET PTD PAINTED FOR NAILING OF ALL INTERIOR AND EXTERIOR TRIMS. FINISHES, AND FIXTURES. THE DTL DE-4 PL PLASTER. PLATE DIA DIAMETER P LAM PLASTIC LAMINATE INSTALLATION OF OWNER FURNISHED ITEMS SUCH AS SIGNAGE. MENU BOARDS ETC. © 3/7/18 CITY CORRECTIONS A BUILDING SECTION DIM DIMENSION PLYWD PLYWOOD 4.0 DO DITTO 23. WHERE EXISTING WORK IS DAMAGED, CUT. OR DEFACED DUE TO PERFORMANCE PT POST-TENSIONED CONCRETE GENERIC NOTES FOR ONE W.C. TOILET RM. DR DOOR PRESSURE-TREATED WOOD SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL 1. UNLESS NOTED OTHERWISE ALL DIMENSIONS SHOWN ARE MINIMUM. aA I DN DOWN BREAK LINES SUCH AS CORNERS, CEILING LINES. TOP OF BASE OR SIMILAR. 2. OVER AND UNDER DIMENSIONS INDICATE ACCEPTABLE LIMITS. WALL SECTION D.S. DOWNSPOUT 3. DIMENSIONS SHOWN ARE ACCEPTABLE MINIMUM, AND MAY BE -40 QT QUARRY TILE 24. THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT DWG DRAWING AND MAY BE REPRODUCED ONLY WITH THE WRITTEN PERMISSION OF THE 4. EXPOSED DRAIN PIPES AND ALL WATER PIPES SHALL BE RECESSED. DF DRINKING FOUNTAIN RL RAIN LEADER INSULATED OR GUARDED TO PREVENT BURN ACCIDENTS. r2� ARCHITECT. AUTHORIZED REPRODUCTIONS MUST BEAR THE NAME OF moo DETAIL REF REFRIGERATOR, 5. GRAB BARS SHALL BE 1 1/4' TO 1 1/2' OUTSIDE DIA. AND SHALL BE Ate/ REFERENCE THE ARCHITECT. ABLE TO SUPPORT A 300 LB LIVE LOAD WITHOUT PERMANENT DEFLECTION. EA EACH REINF REINFORCING BAR 6. PLUMBING FIXTURES AND ACCESSORIES ARE FOR ILLUSTRATIVE PURPOSES t PROPERTY CORNER ELEC ELECTRICAL REV REVISIONRISER, RADIUS ONLY. REFER TO ACTUAL PLANS, INTERIOR ELEVATIONS. SPECIFICATIONS, ECT. INTERSECTION ELEV. EL ELEVATION FOR SPECIFIC FIXTURES AND ACCESSORIES FOR THIS PROJECT. EQ EQUAL R 7. ALL HANDICAPPED TOILET ROOMS FIXTURES AND ACCESSORIES SHALL TOP OF SUBFLOOR (EI EXIST EXISTING RM. RMS ROOM. ROOMS COMPLY W/ CHAPTER 11 AMEDNED OF THE 2012 IBC, ICC A117.7-2002. EL. 10'-10 1/2' ELEVATION MARK EXT EXTERIOR RO ROUGH OPENING 8. ADDITIONAL FIXTURES SHALL BE MOUNTED AS FOLLOWS: 11 T.P. DISP. IF LOCATED ABOVE GRAB BAR SHALL BE LOCATED WITHIN AN AREA BORED SCHEDULE 24' MIN. AND 36' MAX. FROM REAR WALL. WHERE DISPENSER IS LOCATED BELOW 25.00' (NEW) SPOT ELEVATION FO FACE OF. FINISH OPENING SEC SECTION 22ND ST. s THE GRAB BAR. THE OUTLET OF THE DISPENSER SHALL BE LOCATED WITHIN AN SHEET TITLE: AN AREA 24' MIN. AND 42' MAX. FROM THE REAR WALL. THE OUTLET OF THE 23.72' (EXIST.) FRP FIBERGLASS REINF POLYESTERSHT SHEET . .. DISPENSER SHALL BE LOCATED 18' MIN. AND 48' MAX. A.F.F. DISPENSER SHALL 23RO ST. FIDALco COMPLY WITH SECTION 602.3. DISPENSERS SHALL NOT BE OF A TYPE THAT ROOM-NAME FIN FINISH SV SHEET VINYL MY COVER SHEET CONTROL DELIVERY, OR DO NOT ALLOW CONTINUOUS PAPER FLOW. 101 ROOM NAME / NUMBER FAAP FIRE ALARM ANNUNCIATOR SC SOLID CORE 24TH ST. ALLOW MIN. 1-1/2' BETWEEN G.B. AND D1SP. MNT. SOAP DISPENSER PANEL SPECS SPECIFICATIONS ISLAND HOSPITAL MAX. 40' A.F.F. BTM. EDGE OF MIRROR MAX. 40' A.F.F. 1211 24THSTICC A 117.1-2009. SIGNAGEPERIBC 2 ';AND 1 MARKB. PROVIDE ADA B DOOR M R FIRE DAMPER SF SQUARE FEET � 25TH ST. �5 O FD O WINDOW MARK FE FF FI NISHED END FACTORYFINIS HH S & V STAIN & VA R ISH SV SHEET VINYL ANACORTES. WA 2eTH sr. 10. SEE ACTUAL TOILET ROOM PLANS FOR R AC T I o L DIMENSIONS AND N D LAYOUT.YOUT. 11. PROVIDE OPEN ENDED TOILET SEATS PER (4 12. T.O. W.C. SEAT MIN.17' lMAX.10' A.F.F.A.FFS AT SHALL NOT RETURN AUTOMATI CALLY FF FINISHFLOORSTRWY STAIRWAY 13. FLUSH CONTROLS HAND OPERATED OR AUTOMATIC. o FRT FIRE RETARDANT TREATED STL STEEL 27TH ST. 14. MAX. DEPTH OF LAV. BOWL TO BE 6-1/2' DEEP. HAND OPERATED FAUCETS. V STOR STORAGE 1 SELF-CLOSING SHALL REMAIN ON FOR MIN. 10 SECONDS. /� FLOOR MATERIAL FLASH FLASHING zo ADJACENCY FLR FLOOR STRUCT STRUCTURAL z • 28TH ST. 15. FRONT OF LAV. TO BE MAX. 34' A.F.F. MEASURED TO RIM OF SINK. rJ ALIGN F.A. FLUID-APPLIED CUSP SUSPENDED 20TH ST. < i ALIGNMENT OF ITEM FND FOUNDATION THRESH THRESHOLD • CITY OF ANACORTES /,� FOIC FURNISHED BY OWNER. T.O. TOP OF �, / ' � REVISION MARK INSTALLED BY CONTRACTOR T TREAD, THICKNESS = W • PLANNING & BUILDING DEPT: FOIO FURNISHED BY OWNER. TEMPERED o a cc DAPPROVE(D PLANS �L INSTALLED BY OWNER TS TUBE STEEL " PERMIT #: JJL -��l - I / 7 PJC TYP TYPICAL a2NosT. PROJECT ARCHITECT: FCIC INSTALLED BY CONTRACTOR ADDRESS: ( / // 7'1) ,/ PROJECT UNFIN UNFINISHED ELEVATION UNO UNLESS NOTED OTHERWISE _ PJC MARKS GA GAUGE UR URINAL 54TH ST. APPROVED BY: DRAWN BY: GALV GALVANIZED SUBJECT TO FIELD INSPECTION. APPROVED PLANS GAP GENERATOR ALARM PANEL VCT VINYL COMPOSITION TILE L SHALL NOT BE ALTERED WITHOUT AUTHORIZATION. PJC GL GLASS VERT VERTICAL }}�, CHECKED BY: GWB GYPSUM WALLBOARD VIN VINYL S. STATe VR VAPOR RETARDER "I'm 20 HC HANDICAP VTO VENT TO OUTSIDE JJAANEUARY 12, 2018 HDWE HARDWARE WC WATER CLOSET HP HEAT PUMP WP WATERPROOFING 18-201.DWG HT HEIGHT WS WHEEL STOP COMPUTER FILE NAME HM HOLLOW METAL W WIDTH HOR HORIZONTAL WOO WINDOW HB HOSE BIB w/ WITH VICI \ ITY MAP /'N HW HOT WATER WD WOOD HWT HOT WATER TANK WI WROUGHT IRON 9 201'8 HMD HOLLOW METAL DOOR WRGB WATER RESISTANT " COPYRIGHT 2018 CARLETTI ARCHITECTS. P.S. HMF HOLLOW METAL FRAME GYPSUM BOARD I7 „,„ t .. 1 -_ 71 i . CARLETTI ARCHITECTS PRS, � pl nning,interior design i g n — -- - ., architecture, 0.-3 --- _I FIR STREET� \ SUITE A ,. _ MOUNT VERNON. WA. 98273 Phone: (360� 424-0394 Fax: 360 424-5726 I I -___.. .. ..---_... . _ -- I _ _.. i - L-:.-_ �z9 C STERED J i ( I ITECT PhTL�tt OFFICE S A1E WASNINGTGN - _ � ,T I I , /$ 'T4I 1-U- ,,_. _ _. 1r---: c T. 1.1. , QOFFICE ,� �I ' 1 ___ e IS-0 / '' ` '.� ISLAND HOSPITAL PRIMARY CARE CLINIC EXAM II. I�' s �:: - 3--- EXPANSION AND IMPROVEMENT E,E :I OB GYN CLINIC : _ EXAMsic ''1 OFFICE I la. LAB �: EXAM 27 26 25 24 22 21 20 18 17 16 15 -------I 1 1 IS•06 — it-- ( n U 14 112) 111 (110) 'I'I ., �NEW CABINET YP) ,..... / I CONTACT: \, i no°P�a / �. ®. II " .`.... k .:::.: - .-....— ,. ..._._. ® — � —� t� ! ' �s' t_' tn" 1---).D , MIKE MCKENNA ,� : ,.. . Li EXAM, " flU IS-05 PROCEDURE EXAM61 7 7 ,, V' 0 BREAK gRa / IS-08 "' ' - ri). r\61. 0 132 1 6-04 �.� ELECII ��� WORK corm x I�" �r' ISLAND s o of FM Io k91 ! \ (12 13 ) ® AP _ , (r.y 109 Mo: TD SURGEONS, FIvTA 23 JC _ BREAK PROCEll01IE OFFICE P.S., INC. I OBGYN - E. 9 SCHEDULING II -711117 o �'r �r, ■ — i— j S-03 BBxba •02 Li , coueTERroP,r»meABEcasINETG ■ 101 _ UPPER CABINETS 118 117, (102 t 108 � _-. =-- - DUCT `4X45TFEL CGLUMN 1 O �l .......� __ ® •1037 Jj y` — __-- - WSTINGTS COMP)) \ -_ / 1 0 - _� _.... ..... __. $ �MNtGUEE ... ..: i,' E. Li t \ � 5 11 DLO/WAITER �, 18-201 COMMON AREA Y It " — NIWJtc I NUMatK: MAIN EXIT EXISTING W/ PANIC HARDWARE M 0 A ExAm % 'i` FM O3 71) REVISIONS: COUNTER - - ;__ ..�-; I 401triiiiii. L -. -p --.E_- ._-.....i �, ---:�t • --...- -,,;tQ i� .............. __-.1 • ® -i ® kl. _. _ 2/20/18 PERMIT/BID SET SECURITY GATE T .SECURITY GATE • .-... - I -Y 1 I '' \l --_ 00 as --- FM 03 _..1 , ,). 0 n g ( 4 � ( 6 � 7 ( 8 � 9 '; 104 105 106 FAMILY COUNTER Mos o> ) UEE - IdA6GIE I ( OFFICE I �—j ' �I ., ?y II— �1711 t T• owe 217 PHARMACY71 Ic! _-_ _ J01 1 EXAM EXAM 1 9 LUNCHROOM t , bco ® �E 1� _ _ lit L 4113. _ ' , O K L -� r — — ------ �FM-OD EXAM - EXAM IT:--)).fl}tr "'g• MANAGER � — I — gLiilG:An�fl99E , :��ti.�m � A � I - OFFICE �B 0 / ` II�1� 11_ �® IE--B 4" 141•11' 1-7 ® �IE20� � 1 E. i' 1 0 CLOSET o I ® SHEET TITLE: �EO'BYPASS DOOR �D1W,STFkl1!@S,4O@I \` / 1 o MAIN EXIT EXISTING , IE-14 -7 1_.....\ � �� _ �-a'rr > OVERALL FLOOR PLAN CHAIR RAIL , 0 31 p W/ PANIC HARDWARE r-- �( p T �` -' 37• �•� OFFICE Q �Lt 6 BREAKWAY PANELSS®C�ASSOCIATES �E 24� 4 TRG �� IE 13 ® STEPTHISPoRTgN /��� (//Q�� FS 1 a FCHAIRRAII y I. CORSi00c OF COUNTER DOWN __' __..__..-.-.. . -..___-.__. _._........ .___...___-. 1g'- " ROUNDED TO ADA HEIGHT in CHAIR GLASS 4 - IE 16 OFFICE o NORTHWEST, 0 CE-0� 1 IFFIC A-2,1 ( 0 UROLOGY F H�'�sHELVEs f . LOCKABLE DOORS ®98•,80• ON UPPERS 872"AFF 7 n -IL 1 NOE EMUS-TAW ISLAND LYE - A SUBEOT ST - , EXAM EXAM • ` 1s'0" >I AIRGR ,E, I PHYSICIANS,SURGEON��NC, _ o_- o WAIT �E _ TO PIOWE'OAA CH9NGSPERIgLk RETURN 07 IE 04 IE 08 41010110 Lfi � 1 al- /� MAIN EXIT EXISTING .r L- 1 0 NG�e EL —WOW \V/ PANIC HARDWARE �9.1 I BREkKWAY PANEL CE Oq, LAB CHARTS LARGE EXAM I L_ 1 it -kt J GE-02) EXAM o PJC — — — f— — — TEL IE 05 BILLERS IE 06 EXAM 4 IE 10 _ ::CTARCRITCT 1 9fi I — ( I C 211-10}" 1 I f -1T-0' ) F10'� MD" t0:-0.� DRAWN BY: y V PJC 60'-1}" CHECKED BY: JANUARY 12, 2018 DATE 18-201.DWG COMPUTER FILE NAME A ....=.___ 2 . 0 OVERALL EXISTI \ G FLOOR PLA \ 1/8'4-0' � ' � � O 20tV COPYRIGHT 2018 CARLETTI ARCHITECTS. P.S. ■ DEIVO LEGEND: v EXISTING FRAMED WALL OR WALL FURRING TO REMAIN FLOOR PLAN KEY NOTES Kw-A EXISTING LOAD BEARING MASONRY WALL TO REMAIN FLOOR PLAN NOTES: 0 NEW CASEWORK WITH UPPERS. SEE CASEWORK ELEVATIONS. 1. COORDINATE WITH HOSPITAL STAFF ON ITEMS TO BE SALVAGED AND SAVED PRIOR TO REMOVAL. EXISTING COLUMN TO REMAIN 2. NOTIFY ARCHITECT IMMEDIATELY IF CONDITIONS VARY FROM THOSE SHOWN �Od EXISTING WALL AND OR ITEMS TO BE REMOVED AL NEW CUBICLE CURTAIN TRACK AND CURTAIN. PROVIDE AND INSTALL STEEL STUD OR IF UNFORSEEN ISSUES ARE DISCOVERED. LIGHT GAUGE SUPPORT FRAMING ABOVE ACP AS REQUIRED TO SUPPORT TRACK.. 3. PROVIDE BLOCKING IN WALL FOR ALL F.O.I.O. INCLUDING: SOAP DISPENSERS. PAPER TOWEL DISP. �+ ORELOCATED SALVAGED DOOR AND FRAME/HARDWARE 0 NEW SINK WITH NEW FAUCET. SEE MECHANICAL DRAWINGS. SEAT COVER DISP.. TV. CEILING MOUNT ECT. CONTRACTOR TO FURNISH AND INSTALL ALL GRAB BARS. CARLETTI ARCHITECTS P.S. 2 SEE DOOR SCHEDULE SHEET A-2.3 architecture,planning,interior design - 5 NEW TOILET AND LAV. MATCH EXIST. SEE MECHANICAL DRAWINGS. DEMOLITION KEY NOTES: 116 EAST FIR STREET 4 REMOVE EXISTING NON-BEARING WALLS AS NOTED. Q EQUIPMENT/FURNITURE F.O.I.O. SUITE A MOUNT VERNON, WA. 98273 5 GRAB BAR F.C.I.C.. PROVIDE BLOCKING IN WALL AS REQ'D. EXIT PLAN NOTES: REMOVE EXISTING DOORS/FRAMES. SALVAGE FOR RELOCATION/REUSE FLOOR PLAN LEGEND: Phone (3601 424-0394 0 NEW CASEWORK SEE CASEWORK ELEVATIONS. 1. TRAVEL DISTANCE TO COMMON PATH OF TRAVEL < 75'-O' PER Fax: 1360) 424-5726 4) REMOVE EXISTING PLUMBING FIXTURES. CAP EXIST. PLUMB. FOR FUTURE USE i---/-- EXISTING FRAMED WALL OR FURRING TO REMAIN TABLE 1014.3 W/0 FIRE SPRINKLERS (OKI SALVAGE FIXTURES AS DIRECTED BY OWNER. 5 CORNER GUARD EZA EXISTING LOAD BEARING MASORNY WALL TO REMAIN 0 REMOVE EXISTING CASEWORK. SALVAGE AS DIRECTED BY OWNER. EXISTING STRUCTURAL COLUMN TO REMAIN 2. OVERALL EXIT TRAVEL DISTANCE < 200'-O' FOR (B) OCC. WITHOUT SPRINKLERS PER TABLE 1016.2 (OKI NEW WALL FRAMING OR INFILL SEE WALL TAGS a4as 4) FOR PLUMBING AND ELECTRICAL CONNECTION NOTE THAT THERE IS SPACED BELOW 1 = i NEW WALL FURRING SEE WALL TAGS 3. (1) EXIT PROVIDED AND (1I ARE REQUIRED PER 1015.1. SINCE WE HAVE E STEREO THE REMODELED SPACE FOR ACCESS FOR PLUMBING AND ELECTRICAL O LESS THAN 50 OCCUPANTS LOAD. (OK) ITECT 4, REMOVE EXISTING FLOORING. VINYL RUBBER BASE. TYPICAL WITHIN EXIST. SPACE. DOOR TAG SEE SHEET A-2.9 101 ROOM NUMBER SEE SHEET A-2.9 PETER T11 STATE WASHINGTON 0 SEE MECH. DWGS. FOR DEMOLISHED DUCTING AND PLUMBING FIXTURES. TYP. 1 WALL TAG NUMBER SEE SHEET A-2.3 0 REMOVE ALL EXISTING ACP GRID. CEILING PANELS AND LIGHT FIXTURES. SALVAGE 2A10BC FIRE EXTINGUISHER IN CABINET AS DIRECTED BY OWNER. TYP. FE RELOCATED AND OR REMOVE/MODIFY ALL FIRE ALARM HORNS AND STROBES. I—I DIRECTIONAL EMERGENCY EXIT SIGN HARDWIRE ISLAND HOSPITAL SEE ELECTRICAL DRAWINGS TYP. P W/ BATTERY BACKUP PRIMARY CARE CLINIC COORDINATE ALL MECHANICAL/ELECTRICAL ROUGH IN PRIOR TO ANY COVER OF �CX�I COMBINATION EXIT SIGN/EMERGENCY LIGHTING W/ EXPANSION AND IMPROVEMENT 0 WALLS AND OR CEILING CAVITIES. COORDINATE ALL ROUGH IN MECHANICAL � BATTERY BACKUP HARDWARE 06 GYN CLINIC AND PLUMBING REQUIREMENTS FOR EQUIPMENT WITH TENANT. TYP. EMERGENCY LIGHTING W/ BATTERY BACKUP HARDWARE REMOVE EXISTING WINDOW AND FRAME 0 REMOVE EXISTING DOOR AND FRAME. Host 0 REMOVE DRYWALL AS REQ'D. AT EXIST. EXTERIOR FURRED WALLS TO ALLOW FOR NEW ELECTRICAL DEVICES AND CONNECTION TO NEW RELOCATED ELECTRICAL PANEL CONTACT: MIKE MCKENNA - -------1— 1 — ' ........i......Nez„../ `••N PATCH/FILL IN WALL AS REQ'D AT FORMER SHAFT LOCATION I--7-- ----- -I L -n — FILL IN `> J - � ` J— // n © — WINDOW OPENING Ark F 0 0 0 // II I1 © 0 COLUMN re 4111 L - — rLi v r/r///J f71//rrr. - I 1 _ 18201 PiP , 1 Z 1 EXAM-5 -- - ' ') - - PNUJGI NUMl3tN TIFF Q HALL91. 10�� _ '�Rv\ _7 �7 ULTRASOUND - 112 a j I I HI _ � _ _ � i i 19 // �% �� 4� o '�, 9-0 T 108 101 REVISIONS: I I I I X / H, ��T � � �/ 0 1 — EXAM 1 �,e. 2 2/20/18 PERMIT/BID SET I' 1 1° �j I f INSTALL BLOCKING /!L 102 © 3/9/18 OWNER REVISIONS �I. I�f _ I _ _ 1 4. ✓ 0 IN WALL FOR MTD'— — — - 1 V ` �_ r r � _ _ - ✓ qv VIDEO MONITOR ( _._� t O / / EXAQ 4�� -Err—, -� — —E'OIL-tiMN — — — ) 01 L-� —1 —1 k� 1/ri u © 0i o 0 )) u - — — 1 / o NEW 6' CONC SLAB _ I o =1 / / .r FOR CONDENSOR UNIT 2'-3 1 �L —- _ / SLOPE AWAY FROM / ( / 5 / 3/15 ! � i- 4, %� - ___/ 1 BUILDING TYP. 1 MA'S/RN'S A-23 �' L — — J THICKEND EDGE ; -■ i_ 113 a :::... .... _ _ .. . .._ a j�.. 1 O 12' DEEP 0 PERIMETER i , :)) J T I I — — / I L I © — -� O © � EXAM-2 lie / i 9 %I I 0 0 I n -1 1 1 ;... I / 1 103 0 ;': SHEET TITLE in ;/1 1 I ,. I H H I I = _ =i EXAM-3 / — 1 - FILL IN 1® x PO 6 = _ _ O l I J / 00 0 1 © DOOR OPENING ,i _ HALL O m DEMOLITION FLOOR PLAN �� I 102 ® 9 PROPOSED FLOOR PLAN T-91' EXIST. I © 1 0 COLUMN 1 U — — — — — /1 I D 64" �_6 1 �I - - - Sr===� rr — _ _ � h41 � � — STUDS VESTI6ULE 4 1 II I II / I A I © 11 1 i- ,� 11 / v / H / 9-6 S ALES ;F { III III / I \ II II / III \ LLL = / = } : .r MO 1 (. \ Ir I u,- u 1 \ 3 �r A fi) -a3 14'-OI H 0 ELEC. I - 0 I ii © �� , .LEAN ;, PANEL. C. I © © H I - D DOCTORS ASSTHRU sea�� DIRTY 105 40 � � 114 6, 106 ry o ��a 1 EXAM-66 Ai 0 I I 1 0 law O 3 a-ss 104 2 f; I I et I 0 © 0 0 R.R. 8 �--� I PJC I 9 107 'o ■I, —, 1 ) PROJECT ARCHITECT: r 0 © ©, L - --- ® --- IT-3 - - C' TEL. iIA 04 PJC — 0 I DRAWN BY: - - - . /_ - - - -- - - r / / > _- 7?T�r/ � ,� �1/ITS-Z_ITTI:LTL�'1//�� -----_TI/LT_-/1/ //IT.,1,/TTI-T. _/1� 17_//>T. .,-._ !L_1_IT/lil.-J / , � /. / .T-I�/, /. TI/// .. ............. 7�/Ll, � l/1l l /<I��711_JZIlTl�l7 l�il:: TIITT. / I.1.I/T!/ / ,,11 / I/� t lTT../_�.TI<.-LL11�1., /1 _,.--.-. _ ,.:: PJC CHECKED BY: 48'-7 ,----/- ii 1O �� Nea/ JANUARY 12, 2018 e� 9 DATE 18-201.DWG c7itJ' v1 , COMP TER FILE NAME \� ,, /� .- / � DEVO / EXISTI \ G PLA \ 2 PROPOSED FLOOR PLA \ D 1/4'm1'-0' —1 0 1/4'a1'-0' p O 9 201E COPYRIGHT 18 CARLETTI ARCH CIS. P.S. ifil 1 4. CARLETTI ARCHITECTS P®S, architecture,planning,interior design 116 EAST FIR STREET SUITE A MOUNT VERNON, WA. 98273 PROPOSED CEILNG LEGEND: Phone: (3601424-0394 Fax: 360 424-5726 ® NEW 2X2 LED LIGHT FIXTURE SEE ELECTRICAL DWGS. rci NEW 2X4 LED LIGHT FIXTURE SEE ELECTRICAL DWGS. Aik 6429 V4ISTERED 0NEW OCCUPANCY SENSOR SEE ELECTRICAL DWGS. AAA, ITECT NEW UNDER CABINET SEE ELECTRICAL DWGS. ,� — — — PETER '� —�av O NEW LED CAN LIGHT SEE ELECTRICAL DWGS. STATE •>�wnswNcroN o NEW LED VANITY LIGHT/WALL MTD. SEE ELECTRICAL DWGS. DEMO CEILING LEGEND: i NEW DIFFUSER SUPPLY GRILLE SEE MECHANICAL DWGS. NEW RETURN AIR GRILLE SEE MECHANICAL DWGS. ISLAND HOSPITAL EXISTING LIGHT FIXTURE SALVAGE AS DIRECTED ® PRIMARY CARE CLINIC EXISTING RETURN AIR/DIFUSSER GRILLE REMOVE o+ NEW SPEAKER SEE ELECTRICAL DWGS. CONNECT TO SYSTEM EXPANSION AND IMPROVEMENT OB GYN CLINIC C) EXISTING CAN LIGHT REMOVE SALVAGE AS DIRECTED REMOVE ALL EXISTING SUSPENDED CEILING GRID iss , AND TILES TYP. ENTIRE SPACE CONTACT: MIKE MCKENNA i i 1 aell3/43/4-N3/4'%I.NN\ I — y / , 1 / II II X j <i;/ J s 8 or r I Jo r , vI I I I � IX a � a UtC I NUMEStR: LJ ` ` t I I Ij � 11 II H) I I I [ _ J t REVISIONS: \ )\\N i 2/20/18 PERMIT/BID SET I I 11 —� I As, 3/9/18 OWNER REVISIONS - - - - _ N� aJP1c? T OCir � / /,� 0l 411 N ( I ) . (— 1 II r" ✓ (I)/ 0 7 : I T //� I I— H I I c = = = i ✓� �� (� \� XLn SHEET TITLE: 11/I L = = = LL AL _I I / — r 1 / oc • DEMOLITION CEILING PLAN iI ✓ PROPOSED CEILING PLAN ir fI / _ / I l F �� F �_� saa_ ° Li L 1J - - - _ ___ _ - - - _ h rR Fn T T f V 11 111 / \ I I LI I\ III v� 11 I ° , � III \ ,r=2/ XIN I r 1 oc g /� ELEC. I ;I III �� 4 X r , PANEL. I 0 I E-' 1' - - ar T r r, I 1' H PROJECT ARCHITECT: 1 �S • II PJC 1 \I G-3 �IT.� TEL / : . _ 1� — DRAWN BY: . ...-F.F.- _ ._.__ ...._.. . .. ............... ....._- -- --. . , t/1/ / / % 7 111h _....... ..........-� �-� � - � - ; � i - � � / � - ----— —: �� 1l I::/lL1T/._l_,. _.... h.�---G/IILLLLr1�l l-_%LlLl/h-��,' 7ll/ / IITi i <.'.1/ ;I_1z r ...__-_.._ �Tl7T!< 1.:..IT7_/T1; l,C/T7T./1..T._TI/l�T,-.T, T.Tl7l/.-///._/ll_//, ////////�L�LL1,� 7 Ill/�.I jllllLL1 1.�'.��i<?[ 1�«'TTlTTT I//I 7::Ta'lZlt_l./I1Z_� _. _. ___ _ ___11I1'T.1._1111111LL/11l PJC CHECKED BY: $ I © a ?v.): 'C/ 7 W7 ® r JANUARY 12. 2018 ''^^/�� DATE 1 01\e 18-201.DWG COMPUTER FILE NAME triplingA igl% .r DEMO / EXISTI \ G CE1L1 \ G PLA \ -1 ps2 PROPOSED CEIL1 \ G PLA \ _ . 1/4'a1'-0' 1/4'a1'-0' ® ' COPYR T 2018 CARLL°TTI ARCHIT- TS. P.S. I DOOR SCHEDULE NO. SIZE DOOR LEAF FRAME CLOSER RATING PANIC HARDWARE NOTES TYPE MAT'L. FIN. MAIL. FIN. GROUP 1 3'-0' X 6'-8' C WD CLR HMF PNT YES - - - NEW DOOR AND FRAME REUSE EXISTING LEVER HARDWARE FROM EXISTING ENTRY DOOR 2 3'-0' X 6'-8' A WD CLR HMF PNT - - - - REUSE EXISTING DOOR AND FRAME EXIST. LEVER HANDLE HARDWARE 5 3'-0' X 6'-8' A WD CLR HMF PNT - - - - REUSE EXISTING DOOR AND FRAME AND EXIST. LEVER HARDWARE DOOR TYPES 4 3'-0' X 6'-8' A WD CLR HMF PNT - - - - _NEW DOOR AND FRAME AND NEW LEVER HARDWARE MATCH EXIST. CARLETitTctuAIRCHITEC ARCHITECTS P. 5 5'-O' X 6'-8' B WD CLR HMF PNT YES - - - REUSE EXISTING DOOR AND FRAME AND HARDWARE ADD A CLOSER AND S.S. KICKPLATES n 8�S b�( '-8' A WD CLR HMF PNT YES - - - REUSE EXISTING DOOR AND FRAME AND EXISTING HARDWARE LEVER HANDLE PRIVACY LOCK T 7 3'-0' X 8'-8' A WD CLR HMF PNT NEW DOOR AND FRAME AND NEW LEVER HARDWARE MATCH EXIST. 116 EAST FIR STREET T ,'�'�� SUITE A 8 3'-0' X 6'-8' A WD CLR NEW POCKET DOOR WITH BARRIER FREE HARDWARE 0 5'-O' X 6' A WD CLR HMF PNT NEW DOOR AND FRAME AND NEW LEVER HARDWARE MATCH EXIST. �,, MOUNT VERNON. WA. 98273 tste_____ 9'-0' 6'-8' A WD CLR HMF PNT _ EXISTING DOOR AND FRAME AND EXIST. LEVER HARDWARE TO REMAIN 424 0394 11 3'-0' X 6'-8' A WD CLR HMF PNT - - _ _ _ EXISTING DOOR AND FRAME AND EXIST. LEVER HARDWARE TO REMAIN Phone: 1360Fax: f 3601 424-5726 13 9'-0' X 8'-8' A WD CLR L 12 3'-O' X 6'-8' A WD CLR HMF PNT - - - _ REUSE EXISTING DOOR AND FRAME NEW LEVER HANDLE WITH KEYED LOCK HARDWARE REUSE EXISTING DOOR AND FRAME NEW LEVER HANDLE HARDWARE MATCH EXIST. TYPE A TYPE B TYPE C I( '" . NOTES: T•TEMP _ 1. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. __n 4"" 2. ALL GLAZING WITHIN A 24 INCH ARC OF EITHER EDGE OF DOORS AND WITHIN 18 INCHES OF FLOORS SHALL BE SAFTY GLAZING AS I 8429 STEREO REQUIRED BY IBC SECTION 2406.3. ALL SUCH GLAZING SHALL HAVE PERMANENT IDENTIFICATION SAFTY GLAZING STAMP. �. �, cot% . ITECT rg 5. DOORS SHALL HAVE LEVER HARDWARE WHICH WILL PERMIT OPERATION BY WRIST OR ARM PRESSURE ,,�' 4. DOOR SPECIES TO MATCH EXISTING MAPLE. DOORS TO BE 1-3/4' SOLID CORE. l. ' — P J. C ^�•,-• -- • _ - i "� STA OF WASHI` TON FINISH SCHEDULE ""- - - ROOM ROOM FLOOR BASE NORTH WALL SOUTH WALL EAST WALL WEST WALL CEILING NOTES: MA'S/RN'S 113 NUMB. NAME MAIL FIN. NO. MAIL FIN. NO. MAIL FIN. NO. MAT'L FIN. NO. MAT'L FIN. MAIL FIN. MAIL FIN. NO. HGT. 100 ISLAND HOSPITAL 101 HALL LVT FF LVT-1 VRB FF VRB-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 7'-8' 102 EXAM-1 SV FF SV-1 VRB FF VRB-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 -GWB PNT P-1 ACP FF ' ACP-1 7'-8 PRIMARY CARE CLINIC 103 EXAM-2 SV FF SV-1 VRB FF VRB-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT - P-1 ACP FF ACP-1 7'-8' EXPANSION AND IMPROVEMEN 104 EXAM-6 SV FF SV-1 VRB FF VRB-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 T-8' PENCIL OB GYN CLINIC SV FF SV-1 SV FF SV-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 7'-8' COVED SHEET VINYL BASEA DRAWER / rA� 105 CLEAN V v 106 DIRTY SV FF SV-1 SV FF SV-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT PNT-1 7'-8' COVED SHEET VINYL BASE �� Ar 8' TILE TO 72' A.F.F. GWB PAINTED ABOVE SUPPORTS p-dr0 \ yr \,} ��,/ 108 RESTROOMRAU SV FF SV- TILE FF VRB-2 GWBFF T-2 /GWB PNT P 1 GWB PNT P-1 IGwE PNT P 1 GWBPNT P-1 GW9 PNT P-1 GWB PNT P-1 ACP FF ACP-1 7'-8' i '"` HOSPITAL 108 ULTRASOUND SV FF SV 1 VRB8' - F.E. \ CONTACT: 100 EXAM-3 SV FF SV-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT P-1 GWB PNT PNT SV FF SV-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT P-1 GWB PNT P t GWB P 1 ACP FF ACP-ACP FF 1, T-8' in ._TENUEM7. ®® »o EXAM-4 P-1 -GM PNT ®®•�m�Ma®� �.....----- ._.^ �` MIKE MCKENNA 111 STOR. SV FF SV-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 T-8' I" 1D —�� iv - a to 112 EXAM-5 SV FF SV-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 T-8' `� 113 MA'S/RN'S LVT FF LVT-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 .GWB PNT - P-1 ACP FF ACP-1 T 6' I _------ ----_A__ - - \ 114 DOCTORS CPT FF CPT-1 VRB FF VRB-2 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 GWB PNT P-1 ACP FF ACP-1 7'-8' CARPET TILES rTh MA'S 15 M 14 MA'S ®RNS 1 1/4' • 1'-O' / 1/4' • V-O' 1/4' 1'-0' 1/4' • 1'-0' INTERIOR MATERIALS LEGEND ABBREVIATION DESCRIPTION $ SIZE MANUFACTURER: STYLE: COLOR: NOTES: FLOOR/BASE: LVT LUXURY VINYL TILE 1 MANNINGTON ' r- SV SHEET VINYL 1 ROLLED GOOD - MANUFACTURER'S STD. SELECT - SV COVED SHEET VINYL 2 4' H - - MANUFACTURER'S STD. SELECT - iTir) 18 201 CPT CARPET TILES 1 24'X24' - - _ MANUFACTURER'S STD. SELECT - DOCTORS VRB VINYL RUBBER BASE 1 4' H JOHNSONITE - MATCH EXISTING MITER ALL CORNERS 18-201 I NUMbtK: 114 VRB VINYL RUBBER BASE 2 4' H JOHNSONITE - MATCH EXISTING MATCH EXISTING TILE PORCELAIN TILE FLOORING 1 12'X12' TILE - - MATCH EXISTING MATCH EXISTING TILE PORCELAIN TILE WALL 2 12'X12' TILE - - MATCH EXISTING MATCH EXISTING REVISIONS: SIM TO GROUT EPDXY GROUT 1 MARPEI - MATCH EXISTING MATCH EXISTING PAINT: j ELEV. 11 2/20/18 PERMIT/BID SET PNT PAINT 1 - SHERWIN WILLIAMS EGGSHELL - MATCH EXISTING `-_.--.-... -_ ..-..__. © 3/9/18 OWNER REVISIONS PNT PAINT 2 - SHERWIN WILLIAMS EGGSHELL - MATCH EXISTING CASEWORK: P-LAM PLASTIC LAMINATE 1 SHEET GOOD FORMICA STANDARD - COUNTERTOPS P-LAM PLASTIC LAMINATE 2 SHEET GOOD FORMICA STANDARD - CASEWORK FACES DOORS/DRAWERS CEILING: ACP I ACOUSTICAL CEILING PANEL 1 2' X 4' ARMSTRONG FINE FISE:URED HIGH NRC 1728 WHITE I SQUARE LAY-IN W/ 15/16' SUSPENSION SYSTEM COLOR WHITE X T-3' 1 iii iV PENCIL• PENCIL SUPPORT DRAWER DRAWER oDIVIDER P.LAM B.S. &. N BEYOND COUNTERTOP ®®a FE FESH T TITLE: 7 1 m SUPPORT��� _ NDIVIDERBEYOND DOS R SCHEDULE FI4ISH SCHEDULE ��\ EXAM 5 12 DOCTORS 11DOCTORS - NISHES IlL4111: limarlsal,4111.41 C ) 1/4' 1'-0' 1/4' • r-o INTERIOR ELEVATIONS A ........... . . r/ 2 4 — — — — — a — — — — Q e ' T. EXAM-4 4 ULTRASOUND I — I CLEAN CLEAN I DIRTY I DIRTY 102 103 � 104 1 SHELVES w/ EXAM-1 EXAM-2 EXAM-3 110 108 1108 I 1 PROCEDURE I 1os 105 I 106 I PJC BRACKET SUPPORTS PROJECT ARCHITECT AS REQ.D PJC ................. f — DRAWN BY. j f m � 7 1 AMINO P �� K PJC I AAA FROM CHECKED B - , go-_ ' 1 l �.m 1 ' Ll •M COUNTER TO BTM. Y. COUNTER TO BTM. SHELVES o P.LAM S.S. & j I r t UPPERS —� JANUARY 12, 2018 N f COUNTERTOP TY DATE _ _. 1 - - sr K 1 -- ®®III®®rims". , .. _ 41:. I ��_ o I ) �._.__! I 1-> _ / , - ■� \ 18-201.DWG NAME COMP FILE r ; _ COMPUTER F 1 MAR 9 I , A 110 EXAM -1 C2) EXAIV -2 3 EXAM -3 EXAM -4 ULTRASOUV EXAV -6 CLEAN DIRTY CCOPYRIGHT 2018 CARLMTTI ARCHITGCTS. P.S. 1_o• 1/4' • 1'_0 1/4 1 O' 4 1!4' • 1'-0' S 1/4' 1'-0' CS 1/4' • 1'-O' CCLEAN 1/4' • 1'-O' 1/4' • 1'-0' 1/4' • 1'-O' @DIRTY 1/4' 1'-O' 1/4 1 8'-0' A.F.F. Er U.N.O. 1 31 ' MTL STUDS A.F.F. 8'-0' A.F.F. t - 30 MIL 0 16' O.C. 4 8'-0'U.N.O. r U.N.O. r 'R•-- 1 3i ' MTL STUD FURRING 6° MTL STUD 30 MIL 0 16° O.C. i 90 MIL 0 16' O.C. X' GWB (GREENBOARD 0 STROOMS► PAINT TYP. VAPOR BARRIER i, �, -- "1 .----- r RE ' ! ---- . 0 R-13 BATT INSULATION -- _. ( . 'X' GWB PAINT CARLETTI ARCHITECTS PS, architecture,planning,interior design - SOUND BATT INSULATION `' X' GWB PAINT BASE AND FINISH ` 116 EAST FIR STREET -"-.. 1 ( EXISTING BRICK WALL. SUITE A PER SCHEDULE _- SOUND BATT INSULATION MOUNT VERNON, WA. 98273 � : : � _ : ( .' Phone: (360) 424-0394 { BASE & FINISH BASE 6 FINISH Fax 360 424-5726 PER SCHEDULE PER SCHEDULE ----------2 FRAME WALL TO MIN. 8'-0' A.F.F. A KICKER TO ABOVE WITH STL. SUPPORTS FRAME WALL TO MIN. 8'-0' A.F.F. FRAME WALL TO MIN. 8'-0' A.F.F. 6429 E STERED SEE DETAIL 15/A-6.0 2 KICKER TO ABOVE WITH STL. SUPPORTS 1 KICKER TO ABOVE WITH STL. SUPPORTS ITECT SEE DETAIL 15/A-6.0 SEE DETAIL 15/A-6.0 PETER STALE WASHINGTON STEEL STUD KICKERS 0 5'-0' O.C. FRAME TO ' STRUCTURE ABOVE MTL STUD WALL PER Cloy, WALL TYPES _ (�I ISLAND HOSPITAL I err LAY-IN FACED SOUND MTL STUD WALL PER it SOUND BATTS Barns 24 EA. SIDE WALL TYPES T PRIMARY CARE CLINIC ' rt / .11-----k ) -2 TOP of WALL TYP. samos_"� EXPANSION AND IMPROVEMENT y i ' t IIII SOUND BATTS ( SHIM SPACE OB GYN CLINIC et:z LE -__ ) ;\ ;4 [[ '.... f III . . SHIM SPACEr, t 1 . L .[ 1OS ` CEILING RUNNER W/ A.C.T. 5/8' TYPE 'X' GWB l { CONTACT: FASTEN RUNNER TO PARTITION Ajoi BOTH SIDES L HOLLOW W MTL. FRAME MIKE MCKENNA PROVIDE ACOUSTICAL SEALANT AT ALL GAPS BETWEEN CLG & PARTITION 5/8' 'X' GWB EA. SIDE r HOLLOW MTL. FRAME DOOR PER SCHEDULE ' DOOR PER 5J8° TYPE 'X' GWB SCHEDULE BOTH SIDES. FINISH/PAINT SEE WALL TYPES 1sRTITION KICKER DETAIL EH . M . P . — EAD 111H . V . F . JAM3 N.T.S. N.T.S. N.T.S. %I , NI": SUPPORT WIRES 4r 4 18-201 SEE A.C.T. SWAY *IA - PNOJtG i NUMbt.N: )ii BRACE DETAIL, TYP. VERTICAL 12 GA. HANGER WIRE 44 • SPACED 4°-0' O.C. ALONG MAIN BEAM ALL WIRE TIES ARE TO BE (3( VERTICAL STRUT CAPABLE TO STRUCTURE ABOVE. TIGHT TURNS AROUND ITSELF OF RESISTING VERTICAL REVISIONS: WITHIN 3'. LOADS 0 �12'-0° O.C. +' I SEE WALL TYPES BEGINNING 16'-0° FROM (4) 12 GA. WIRES SECURED TO HD A 2/20/18 PERMIT/BID SET \ WALL MAIN BEAM WITHIN 2' OF 1' '�' \\ CONNECTION OF VERTICLE STRUT TO FMAINM BEAM TSPLAYED D90G RDEGREES 0 24 EO. ANCHOR Cj 7�' \r 7, N. 9 FROM CLG OPLANE.4LATERALEFORCE BRACING SHALL BE PLACED 12'-0' O.C. �_ \ 6 2/ j s IN BOTH DIRECT%OHS. WI THE FIRST - .2 - POINT WITHIN 6'-O' FROM EA WALL. \ ;` f SECURE TO STRUCTURE ABOVE. -.. BASE FINISH Oe' PER SCHEDULE O O la 10® V9 �P�N HD MAIN BEAM V� ' cP® A.C.T. a VJ \ S T�e� CROSS RUNNER f NOTE: SUSPENDED CLG SHALL BE INSTALLED PER ASTM C898, NOTE: HANGER & PERIMETER WIRES MUST BE PLUMB WITHIN 1 IN 6 SHEET TITLE: UNLESS COUNTER SLOPING WIRES ARE PROVIDED. CISCA ZONES 3-4 & ASCE 9.6.2.6.2.2 KQ 3ASE. DETAIL WIRE TIES rTh7 CEILI \ G BRACE { A . C . T . SWAY 3RACE DETAILS N.T.S. 82 N.T.S. / N.T.S. 1�6y N.T.S. VERTICAL 9 GA HANGER SPACED #12 GA. WIRE HANGER TO j 4'-O' O.C. ALONG MAIN RUNNER TO r----- STRUCTURE AT EACH STRUCTURE ABOVE. VERTICAL STRUT CORNER OF FIXTURE COMPRESSION STRUT 0 12'-O' O.C. 0 12'-0' O.C. ATTACH SLACK WIRES i (4) 12 GA WIRES SECURED TO MAIN DIRECTLY TO FIXTURE RUNNER. 12 GA. SWAY SUPPORT AT DIAGONAL CORNERS SPLAY 90D FROM Ea OTHER, N.T.E. WIRES 0 12°-0' O.C. SEE DTL 6/A-6.2 45 FROM CLG PLANE. HORIZONTAL SEE DTL 5/A-6.2 Oo o ® o A RESTRAINT POINTS SHALL BE PLACED 12'-0' O.C. IN BOTH DFRECTIONS, Wi GA. SUSPENSION WIRE PJC ARCHITECT: / THE FIRST POINT WITHIN 4'-0' FROM WALL MOLDING • 45 EA WALL. SECURE TO STRUCTURE • COLD ROLLED CHANNEL PJC MAX ABOVE. *' 0 4-0' O.C. y i' N. 16 GA. TIE WIRE DRAWN BY: 1 i/2' COLD ROLLED CHANNEL ATTACH FIXTURE TO 0 4'-0' o.G PJC CEILING SUSPENSION CHECKED BY. 7 ° HAT CHANNEL !8 SYSTEM WITH POSITIVE aint:. 0 2'-0' O.C. 6 CLAMP DEVICES HAVING A// A-62 CAPACITY of toox ofS JANUARY 12, 2018 DATE LIGHTING FIXTURE WEIGHT —® 3" MAX. TYP. IN ANY DIRECTION NOTE: (1) END OF CEILING GRID SHALL BE ATTACHED TO WALL - 18-201.DWG MOLDING. THE OTHER END SHALL HAVE A 5/4' CLEARANCE FROM "` WALL 3 FREE TO SLIDE. GRID SHALL BE ATTACHED AT (2) ► COMPUTER FILE NAME HAT CHANNEL ADJACENT WALLS (POP RIVETS OR APPROVED METHOD( 5/8' GWB 0 2-0' O.C. /; / Q LIG - T FIX . SUPPORT C3 \GRID AT WALL 2 SUSPE \ ED GW3 6 . 0 MMAp N.T.S. 2 N.T.S. N.T.S. MAR 0 9 2018 COPYRIGHT 2018 CARLETTI ARCHITECTS. P.S. + ISLAND HOSPITAL OBGYN .1,0 MECHANICAL & PLUMBING UPGRADES CARLETTI ARCHITECTS PSS, architecture,planning,interior design SYMBOL LIST 2015 WASHINGTON STATE ENERGY CODE NOTES . 116 EAST FIR STREET SYMBOL ABBV. DESCRIPTION SYMBOL ABBV. DESCRIPTION NOTE: ITEMS IN (PARENTHESIS) REFERENCE CODE SECTIONS FROM THE 2015 (C403.2.8.3.1 LOW-PRESSURE DUCT SYSTEMS) CONTRACTOR SHALL PROVIDE ALL SUITE A WASHINGTON STATE ENERGY CODE. LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND CONNECTIONS OF SUPPLY AND MOUNT VERNON WA. 98273 e 0 DUCT SECTION -SUPPLY 10 T'STAT THERMOSTAT (C403.2 PROVISIONS,APPLICABLE TO ALL MECHANICAL SYSTEMS) CONTRACTOR SHALL RETURN DUCTS OPERATING AT A STATIC PRESSURE LESS THAN OR EQUAL TO 2 INCHES WATER GAUGE (W.G.) (500 PA)WITH SECURELY FASTENED AND SEALED WITH WELDS, L O DUCT SECTION - RETURN 0 CO2 CARBON DIOXIDE SENSOR PROVIDE ALL MECHANICAL SYSTEMS AND EQUIPMENT, SERVING THE BUILDING HEATING, GASKETS, MASTICS (ADHESIVES), MASTIC-PLUS EMBEDDED-FABRIC SYSTEMS OR TAPES Phone: (360( 424-0394 COOLING OR VENTILATING NEEDS, WHICH COMPLY WITH SECTIONS C403.2.1 THROUGH INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. Fax: I(3601) 424-5726 20x12 RECTANGULAR DUCT(INSIDE DIMENSION) AFF ABOVE FINISHED FLOOR C403.2.13. PRESSURE CLASSIFICATIONS SPECIFIC TO THE DUCT SYSTEM SHALL BE CLEARLY INDICATED ON THE CONSTRUCTION DOCUMENTS IN ACCORDANCE WITH THE INTERNATIONAL P 12"o a ROUND DUCT ARCH. ARCHITECT/ARCHITECTURAL (C403.2.4 HVAC SYSTEM CONTROLS) CONTRACTOR SHALL PROVIDE EACH HEATING AND MECHANICAL CODE. PERMIT - BID SET COOLING SYSTEM WITH THERMOSTATIC CONTROLS AS SPECIFIED IN SECTION C403.2.4.1, 20x12 SL SOUND LINED DUCT(INSIDE DIMENSION) CDS CEILING DIFFUSER-SURFACE MOUNTED C403.2.4.2, C403.2.4.3, C403.2.4.4, C403.4.1, C403.4.2, C403.4.3, C403.4.4, C403.4.5, C403.4.6, (C403.2.9 PIPING INSULATION) CONTRACTOR SHALL PROVIDE ALL PIPING SERVING AS PART C403.4.7, C403.4.8, C403.4.9, OR C403.4.10. OF A HEATING OR COOLING SYSTEM WITH THERMAL INSULATION IN ACCORDANCE WITH ' Our difference FLEXIBLE DUCT CDL CEILING DIFFUSER-LAY IN TABLE C403.2.9. s engineered. r-� (C403.2.4.1 THERMOSTATIC CONTROLS)CONTRACTOR SHALL PROVIDE INDIVIDUAL (C403.2.9.1 PROTECTION OF PIPING INSULATION) CONTRACTOR SHALL PROTECT ALL www.harrisgroup.com Lrk ADJUSTABLE AIR EXTRACTOR CGS CEILING GRILLE-SURFACE MOUNTED THERMOSTATIC CONTROLS CAPABLE OF RESPONDING TO TEMPERATURE WITHIN EACH PIPING INSULATION EXPOSED TO WEATHER FROM DAMAGE, INCLUDING THAT DUE TO ZONE WHERE THE SUPPLY OF HEATING AND COOLING ENERGY IS PROVIDED. AT A SUNLIGHT, MOISTURE, EQUIPMENT MAINTENANCE AND WIND, AND SHALL PROVIDE l arras FR TURNING VANE CGL CEILING GRILLE-LAY IN MINIMUM, EACH FLOOR OF A BUILDING SHALL BE CONSIDERED AS A SEPARATE ZONE. SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL. PROJECT NO: 0070412.00 / CONTROLS ON SYSTEMS REQUIRED TO HAVE ECONOMIZERS AND SERVING SINGLE ADHESIVES TAPE SHALL NOT BE PERMITTED. Lan VD VOLUME DAMPER COP COEFFICIENT OF PERFORMANCE ZONES SHALL HAVE MULTIPLE COOLING STAGE CAPABILITY AND ACTIVATE THE ECONOMIZER WHEN APPROPRIATE AS THE FIRST STAGE OF COOLING. SEE SECTION (C403.2.10 MECHANICAL SYSTEMS COMMISSIONING AND COMPLETION REQUIREMENTS) © MD MOTORIZED DAMPER DWG DRAWING C403.3.1 OR C403.4.1 FOR FURTHER ECONOMIZER REQUIREMENTS. WHERE MECHANICAL SYSTEMS SHALL BE COMMISSIONED AND COMPLETED IN ACCORDANCE WITH HUMIDIFICATION OR DEHUMIDIFICATION OR BOTH IS PROVIDED, AT LEAST ONE HUMIDITY SECTION C408. —0 BDD BACKDRAFT DAMPER E, EXIST. EXISTING ITEMS CONTROL DEVICE SHALL BE PROVIDED FOR EACH HUMIDITY CONTROL SYSTEM. ISLAND HOSPITAL (C403.2.11.3 FAN EFFICIENCY)CONTRACTOR SHALL PROVIDE FANS WITH A FAN EFFICIENCY ELECT. ELECTRICAL GRADE (FEG) OF 67 OR HIGHER PER AMCA 205. THE TOTAL EFFICIENCY AT DESIGN CONDITIONS PRIMARY CARE CLINIC (C403.2.4.1.1 HEAT PUMP SUPPLEMENTARY HEAT) CONTRACTOR SHALL PROVIDE ALL SHALL BE WITHIN 15 PERCENT OF THE MAXIMUM TOTAL EFFICIENCY. EC ELECTRICAL CONTRACTOR UNITARY AIR COOLED HEAT PUMPS WITH MICROPROCESSOR CONTROLS WHICH MINIMIZE EXPANSION AND IMPROVEMENTS GENERAL NOTES SUPPLEMENTAL HEAT USAGE DURING START-UP, SET-UP, AND DEFROST CONDITIONS. (C403.2.11.5 FAN AIRFLOW CONTROL) CONTRACTOR SHALL PROVIDE EACH COOLING OB GYN CLINIC EER ENERGY EFFICIENCY RATING THESE CONTROLS SHALL ANTICIPATE NEED FOR HEAT AND USE COMPRESSION HEATING AS SYSTEM LISTED IN TABLE C403.2.4.11.5 WITH CONTROL TO VARY THE INDOOR FAN THE FIRST STAGE OF HEAT. CONTROLS SHALL INDICATE WHEN SUPPLEMENTAL HEATING IS AIRFLOW AS A FUNCTION OF LOAD AND ADDITIONAL REQUIREMENTS LISTED IN THIS INSTALL SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING PER S.B.C. EFF EFFICIENCY/EFFICIENT BEING USED THROUGH VISUAL MEANS (E.G., LED INDICATORS). HEAT PUMPS EQUIPPED WITH SECTION. REQUIREMENTS. PROVIDE ENGINEERED AND STAMPED DESIGN DRAWINGS IF SUPPLEMENTARY HEATERS SHALL BE INSTALLED WITH CONTROLS THAT PREVENT REQUIRED BY IBC. CONTRACTOR TO CONTACT OR HIRE A STRUCTURAL ENGINEER TO FR FLOOR REGISTER SUPPLEMENTAL HEATER OPERATION ABOVE 40°F. (C403.2.14 ELECTRIC MOTOR EFFICIENCY) CONTRACTOR SHALL PROVIDE ALL ELECTRIC DETERMINE BUILDING AND SYSTEM IMPORTANCE FACTORS. UTILIZE ISAT OR OTHER MOTORS, INCLUDING FRACTIONAL HP MOTORS WITH C405.8. SEISMIC BRACING COMPANY. GC GENERAL CONTRACTOR (C403.2.4.2 OFF-HOUR CONTROLS)-CONTRACTOR SHALL PROVIDE THERMOSTATICCONTACT: MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE, AND DO NOT NECESSARILY SETBACK CONTROLS THAT ARE CONTROLLED BY EITHER AN AUTOMATIC TIME CLOCK OR OF BEING CONTROL SIGNAL)THE MECHANICAL L PROVIDE EQUIPMENT DAMPERS NOT BELE REFLECT EVERY REQUIRED OFF-SET, FITTING OR ACCESSORY. HSPF HEATING SEASONAL PERFORMANCE FACTOR PROGRAMMABLE CONTROL SYSTEM FOR ALL OCCUPANCIES OTHER THAN GROUP R. CO BEING SEQUENCED Y WITH IMECHANICAL COOLING ECONOMIZERS AND SHALL MIKE MCKENNA CONTROLLED BY ONLY MIXED AIR TEMPERATURE. AIR ECONOMIZERS ON SYSTEMS WITH COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH BUILDING STRUCTURE HWR HIGH WALL REGISTER COOLING CAPACITY GREATER THAN 65,000 BTU/H SHALL BE CAPABLE OF PROVIDING CND OTHER TRADES. (C403.2.4.2.1 THERMOSTATIC SETBACK CAPABILITIES)THERMOSTATIC SETBACK PARTIAL COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET CONTROLS SHALL HAVE THE CAPABILITY TO SET BACK OR TEMPORARILY OPERATE THE THE REMAINDER OF THE COOLING LOAD. HWG HIGH WALL GRILLE SYSTEM TO MAINTAIN ZONE TEMPERATURES DOWN TO 55°F(13°C) OR UP TO 85°F 29°C V. tt,' VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. ( ) (C403.3.3.3 HIGH-LIMIT SHUTOFF)CONTRACTOR SHALL PROVIDE AIR ECONOMIZERS CAPABLE 'Il I.E. INVERT ELEVATION OF AUTOMATICALLY REDUCING OUTDOOR AIR INTAKE TO THE DESIGN MINIMUM OUTDOOR AIR `, C� • , ALL MECHANICAL EQUIPMENT THAT REQUIRES ACCESS FOR COIL PULL, FILTER (C403.2.4.2.2 AUTOMATIC SETBACK AND SHUTDOWN CAPABILITIES)AUTOMATIC TIME CLOCK QUANTITY WHEN OUTDOOR AIR INTAKE WILL NO LONGER REDUCE COOLING ENERGY USAGE. CHANGE, MOTOR CHANGE, COMPRESSOR CHANGE, LUBRICATION, SHEAVE AND BELT OR PROGRAMMABLE CONTROLS SHALL BE CAPABLE OF STARTING AND STOPPING THE , IPLV INTEGRATED PART LOAD VALUE HIGH-LIMIT SHUTOFF CONTROL TYPES FOR SPECIFIC CLIMATES SHALL BE CHOSEN FROM , CHANGE, FAN CHANGE OUT, ETC. SHALL HAVE AN 8-1/2"x11" LAMINATED SIGN SYSTEM FOR SEVEN DIFFERENT DAILY SCHEDULES PER WEEK AND RETAINING THEIR • PERMANENTLY MOUNTED ON THE EQUIPMENT ACCESS PANELS THAT INDICATES PROGRAMMING AND TIME SETTING DURING A LOSS OF POWER FOR AT LEAST 10 HOURS. TABLE C403.3.3.3. /0 LWR LOW WALL REGISTER "THIS EQUIPMENT MUST HAVE A MINIMUM ACCESS OF 36". NO TRADE SHALL BLOCK ADDITIONALLY, THE CONTROLS SHALL HAVE A MANUAL OVERRIDE THAT ALLOWS (C403.3.1.1.4 RELIEF OF EXCESS OUTDOOR AIR)CONTRACTOR SHALL PROVIDE A SYSTEM 4182 THIS SPACE. LWG LOW WALL GRILLE TEMPORARY OPERATION OF THE SYSTEM FOR UP TO 2 HOURS; A MANUALLY OPERATED CAPABLE OF RELIEVING EXCESS OUTDOOR AIR DURING AIR ECONOMIZER OPERATION TO `� TIMER CAPABLE OF BEING ADJUSTED TO OPERATE THE SYSTEM FOR UP TO 2 HOURS; OR PREVENT OVER-PRESSURIZING THE BUILDING. THE RELIEF AIR OUTLET SHALL BE LOCATED MAJOR APPLICABLE CODES: MC MECHANICAL CONTRACTOR AN OCCUPANCY SENSOR. TO AVOID RECIRCULATION INTO THE BUILDING. 2015 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS 2015 INTERNATIONAL MECHANICAL CODE WITH WASHINGTON STATE AMENDMENTS MECH. MECHANICAL (C403.2.4.2.3 AUTOMATIC START CAPABILITIES)AUTOMATIC START CONTROLS SHALL BE C403.3 ECONOMIZERS (PRESCRIPTIVE). AIR ECONOMIZERS SHALL BE PROVIDED ON ALL NEW 2015 INTERNATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS PROVIDED FOR EACH HVAC SYSTEM. THE CONTROLS SHALL BE CAPABLE OF SYSTEMS INCLUDING THOSE SERVING COM- PUTER SERVER ROOMS, ELECTRONIC EQUIPMENT, 2015 WASHINGTON STATE ENERGY CODE OFCI OWNER FURNISHED, CONTRACTOR INSTALLED AUTOMATICALLY ADJUSTING THE DAILY START TIME OF THE HVAC SYSTEM IN ORDER TO RADIO EQUIPMENT, AND TELEPHONE SWITCHGEAR. ECONOMIZERS SHALL COMPLY WITH 2015 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS © BRING EACH SPACE TO THE DESIRED OCCUPIED TEMPERATURE IMMEDIATELY PRIOR TO SECTIONS C403.3.1 THROUGH C403.3. 4. 18-201 I €4 POC POINT OF CONNECTION SCHEDULED OCCUPANCY. I'KOJCZ+ i NUMCtK: EXCEPTION: ECONOMIZERS ARE NOT REQUIRED FOR THE SYSTEMS LISTED BELOW: TYP. TYPICAL (C403.2.4.3 SHUTOFF DAMPER CONTROLS) CONTRACTOR SHALL PROVIDE OUTDOOR AIR 7. VARIABLE REFRIGERANT FLOW(VRF)SYSTEMS, MULTIPLE-ZONE SPLIT-SYSTEM HEAT SUPPLY, EXHAUST OPENINGS, RELIEF OUTLETS AND STAIRWAY AND SHAFT VENTS WITH PUMPS, CONSISTING OF MULTIPLE, INDIVIDUALLY METERED INDOOR UNITS WITH SCOPE OF WORK U.O.N. UNLESS OTHERWISE NOTED MOTORIZEDCLASS I WILL AUTOMATICALLY SYSTEMS OR MOTORS, SERVED ON SINGLE COMMON H ARE NOTUSE OR DURING BUILDINGWARM-UP COO DOWN, AND AN EXTERIOR REVERSE-CYCLE HEAT UMPT WITH VARIABLE SPEED COMPRESSOR(S)AND SPACES SERVEDINREVISIONS: HVAC: THIS PROJECT CONSISTS OF ADDING A NEW VRF SYSTEM TO A PREVIOUSLY Mk EQUIPMENT TAG SETBACK. VARIABLE SPEED CONDENSER FAN(S). THESE SYSTEMS SHALL ALSO BE CAPABLE OF CONDITIONED CLINIC SPACE. A DOAS SYSTEM -THOUGH NOT REQUIRED FOR THIS PROJECT- 0 PROVIDING SIMULTANEOUS HEATING AND COOLING OPERATION, WHERE IN ALL ROOMS 02-20-18 PERMIT / BID SET WILL PROVIDE VENTILATION AIR TO THE OCCUPIED AREAS. NO ECONOMIZERS WILL BE USED (C403.2.6 VENTILATION)CONTRACTOR SHALL PROVIDE VENTILATION, EITHER NATURAL OR WITH VRF UNITS RECOVERED ENERGY FROM THE INDOOR UNITS OPERATING IN ONE MODE PER EXCEPTION 7 OF SECTION 403.3 OF THE 2015 WSEC. ALSO INCLUDED IN THIS WORK IS FLAG NOTE MECHANICAL, IN ACCORDANCE WITH CHAPTER 4 OF THE INTERNATIONAL MECHANICAL CAN BE TRANSFERRED TO ONE OR MORE PERIMETER ZONES (AS DETERMINED BY THE ADDITION OF A BATHROOM EXHAUST FAN, DUCTWORK, DUCT INSULATION, GRILLES/ CODE. WHERE MECHANICAL VENTILATION IS PROVIDED, THE SYSTEM SHALL BE TOTALTO CAPACITY. SYSOR TEMS AND THE OUTDOORCE TIOT SHALL SHALL BE AT LEAST PERCENT65,00 BTU/H IN REGISTERS/ DIFFUSERS, CONDENSER WATER PIPE, AND PIPE INSULATION. CONNECTION (NECK)SIZE CONFIGURED TO PROVIDE NO GREATER THAN 150 PERCENT OF THE MINIMUM OUTDOOR RECOVERYERY EFFE TIVENE S UTILIZING THIS S EXCEPTION C SHALL HAVE OUTSIDE50AIR.HEAT AIR REQUIRED BY CHAPTER 4 OF THE INTERNATIONAL MECHANICAL CODE OR OTHER PS OF THISSIEXCEPS AS DEFINED EY SECTION ON THE FOR THE PURPOSES OF EXCEPTION, DEDICATED SERVER ROOMS, ELECTRONIC EQUIPMENT PLUMBING: EXISTING SANITARY, HOT/COLD/ RECIRC WATER LINES WILL BE UTILIZE AS NEW 10"o CDL TYPE(CEILING DIFF. LAY-IN) APPLICABLE CODE OR STANDARD, WHICHEVER IS GREATER. ROOMS OR TELECOM SWITCH ROOMS ARE NOT CONSIDERED PERIMETER ZONES AND SHALL PIPING IS CONNECTED AS NEEDED TO SERVE NEW FIXTURES. SELECT EXISTING PIPING WILL 300 CFM BE CAPPED AS SHOWN. FLOW RATE (CUBIC FEET PER MINUTE) (C403.2.8.1)CONTRACTOR SHALL PROVIDE DUCTS, SHAFTS AND PLENUMS CONVEYING NOT EXCEED 20 PERCENT OF THE FLOOR AREATHE VRF SYSTEM. OUTSIDE AIR FROM THE EXTERIOR OF THE BUILDING TO THE MECHANICAL SYSTEM WHICH a MEET ALL AIR LEAKAGE AND BUILDING ENVELOPE INSULATION REQUIREMENTS OF DETAIL NUMBER SECTION C402, PLUS BUILDING ENVELOPE VAPOR CONTROL REQUIREMENTS FROM THE STRUCTURAL CALCS M1 o SHEET ON WHICH DETAIL IS DRAWN INTERNATIONAL BUILDING CODE, EXTENDING CONTINUOUSLY FROM THE BUILDING EXTERIOR TO AN AUTOMATIC SHUTOFF DAMPER OR HEATING OR COOLING EQUIPMENT. FOR THE PURPOSES OF BUILDING ENVELOPE INSULATION REQUIREMENTS, DUCT NO STRUCTURAL CALCULATIONS PROVIDED. NO NEW EQUIPMENT OVER 400 LBS. 6 BALL VALVE SURFACES SHALL MEET THE REQUIREMENTS FOR METAL FRAMED WALLS PER TABLE C402.1.2. II RECIRC BALANCING VALVE C403.2.8.2 CONTRACTOR SHALL PROVIDE ALL OTHER SUPPLY AND RETURN AIR DUCTS C C CONDENSATE AND PLENUMS WITH A MINIMUM OF R-6 INSULATION WHERE LOCATED IN UNCONDITIONED SPACES AND A MINIMUM OF R-8 INSULATION WHERE LOCATED OUTSIDE THE BUILDING. —— — — — CW COLD WATER WHERE LOCATED WITHIN A BUILDING ENVELOPE ASSEMBLY, THE DUCT OR PLENUM SHALL SHEET TITLE: BE SEPARATED FROM THE BUILDING EXTERIOR OR UNCONDITIONED OR EXEMPT SPACES ——— ——— — —— HW HOT WATER BY MINIMUM INSULATION VALUE AS REQUIRED FOR EXTERIOR WALLS BY SECTION C402.2.3. COVER SHEET HWC HOT WATER RECIRCULATION SUPPLY DUCTS WHICH CONVEY SUPPLY AIR AT TEMPERATURES LESS THAN 55°F OR HVAC W SANITARY WASTE GREATER THAN 105°F SHALL BE INSULATED WITH A MINIMUM OF R-3.3 INSULATION WHERE LOCATED WITHIN CONDITIONED SPACE. V VENT ALL DUCTS, AIR HANDLERS, AND FILTER BOXES SHALL BE SEALED. JOINTS AND SEAMS SHALL COMPLY WITH SECTION 603.9 OF THE INTERNATIONAL MECHANICAL CODE. 2.72 DRAWING INDEX Sheet Number Sheet Title ;old � � � r M1.01 COVER SHEET 4 PJC *'.., 4/. AREA OF WORK , . M1.1 SCHEDULES-HVAC � ' ' �' """" ' ' , M1.2 SCHEDULES- PLUMBING & PIPING ' 4, ggqqqq M1.3 ENERGY CODE -LOADS - PROJECT ARCHITECT. M2.0 FLOOR PLAN - PIPING E M3.0 FLOOR PLAN-HVAC lo t 1 #� ;.! �t PJC M4.0 DETAILS ,. ff DRAWN BY: a r a ,, ,2 PJC CHECKED BY. JANUARY 12 2018 /ry °, y DATE r c r COMPUTER FILE NAME PLAN PLAN NORTH NORTH VICINITY MAP � r I,' CD SITE MAP entik \ / NTS f >, NTS V 0 1 0 COPYRIYHT 2018 CARLETTI ARCHITECT% P.S. MITSUBISHI CITY MULTI VRF OUTDOOR UNIT SCHEDULE Electrical-Per Module Cooling Heating Nom System Design Max Pipe Refrig Pipe Dim Corrected Corrected Preliminary 208/230 or[460V] Efficiency COP @ Connected Cooling Design Heating Length from High/Low Cooling Total Heating Sound Added Field MCA Tag M-Net Nominal Cooling Nominal Heating IEER/EER 47°F Capacity (% Outdoor Temp Outdoor Temp BC or 1st Pressure(inch) Capacity Capacity Pressure Charge (See Voltage/ 208/230 or Notes / System Tag Reference Address Model Number Modules Capacity (BTU/h) Capacity (BTU/h) [SEER] [HSPF] of NOM) DB (°F) WB (°F) Joint (feet) (See Note 4) (BTU/h) (BTU/h) (dBA) WEIGHT LBS Note 5) Phase [460V] RFS MOCP Options , 208/230V/3- System 1 CU-1 51 PURY-P72TLMU-A P72 72,000.0 80,000.0 28.1 / 14.8 4.3 95.8% 72.0 22.1 56.9 5/8/ 3/4 68,173.0 59,262.6 58 450 22.3 phase 3-wire 24/22 - 35/35 1, 2, 3, 4, 5 CARLETTI ARCHITECTS Pena Notes & architecture,planning,interior design Options: 1 Nominal cooling capacities are based on indoor coil EAT of 80/67°F (DB/WB), outdoor of 95°F (DB) 116 EAST FIR STREET 2 Nominal heating capacities are based on indoor coil EAT of 70°F (DB), outdoor of 43°F (WB) SUITE A 3 Efficiency values for EER, IEER, COP are based on AHRI 1230 test method for mixture of ducted & non-ducted indoor MOUNT VERNON, WA, 98273 4 For systems with multiple modules, refrigerant pipe dimensions indicate total system combined piping downstream of 5 Added field charge listed is in addition to factory charge, this must be updated based upon final as-built piping layout. Phone: 360� 424-0394 Fax: 360 424-5726 MITSUBISHI CITY MULTI VRF INDOOR UNIT SCHEDULE PERMIT - BID SET Peak Fan Airflow Max Fan Sound , Our difference Nominal Nominal Cooling Design Heating Design Corrected Capacity Estimated Estimated Refrig Pipe (cfm)/ ESP Pressure Per Power Power I is engineered. ' Cooling Heating Entering Temp Entering Temp Cooling Cooling Cooling Heating Heating Cooling Coil Heating Coil Dim [Design Setting Fan Speed Cooling Heating www.harrisgroup.com Room Tag M-Net Capacity Capacity DB/WB (°F)/ DB/WB (°F)/ Diversity Total Sensible Diversity Capacity LAT(°F)/ LAT(°F)/ Liquid/Sucti gpm 208V/230V 208V/230V WEIGHT Voltage/ 208V/230V 208V/230V Electrical System Tag Name Reference Address Model Type (BTU/h) (BTU/h) [Water in temp] [Water in temp] Full/Partial Capacity Capacity Full/Partial (BTU/h) [LWT] [LWT] on (inch) G(US)/min] (IN WG) (dBA) LBS Phase (kW) (kW) MCA/MFS Notes / Options Harris Group ZONE Ceiling FULL FULL 208/230V/1- 1.20(208V)/1.20 PROJECT NO: 0070412.00 System 1 EAST FC-1 1 PEFY-P12NMAU-E3 concealed type 12,000.0 13,500.0 78.8/65.8 67.7 DEMAND 11,838.1 8,287.9 DEMAND 10,325.3 57.7 93.4 1/4/ 1/2 371 0.6/0.6 28-30-34 50 phase 0.09 0.07 (230V)/15 1, 2, 3, 4, 5, 6, 7 (ducted) Ceiling FULL FULL 208/230V/1- 1.20(208V)/1.20 System 1 ZONE U.S. FC-2 2 PEFY-P12NMAU-E3 concealed type 12,000.0 13,500.0 78.8/65.8 67.7 DEMAND 11,838.1 8,287.9 DEMAND 10,325.3 57.7 93.4 1/4/ 1/2 371 0.6/0.6 28-30-34 50 phase 0.09 0.07 (230V)/15 1, 2, 3, 4, 5, 6, 7 (ducted) _ Ceiling FULL FULL 208/230V/1- 2.73(208V)/2.73 ISLAND HOSPITAL System 1 ZONE INT FC-3 3 PEFY-P24NMAU-E3 concealed type 24,000.0 27,000.0 78.6/65.7 67.5 23,638.6 19,074.5 20,655.0 58.3 89.1 3/8/5/8 883 0.6/0.6 30-34-39 70 phase 0.17 0.15 1, 2, 3, 4, 5, 6, 7 DEMAND DEMAND (230V)/15 PRIMARY CARE CLINIC (ducted) - _ _ _ C EXPANSION AND IMPROVEMENTS ZONE Ceiling FULL FULL 208/230V/1- 1.56(208V)/1.56 System 1 WEST FC-4 4 PEFY-P18NMAU-E3 concealed type 18,000.0 20,000.0 78.8/65.8 67.7 DEMAND 17,755.9 13,643.2 DEMAND 15,296.9 57.3 91.2 1/4/ 1/2 600 0.6/0.6 28-32-35 60 phase 0.11 0.09 (230V)/15 1, 2, 3, 4, 5, 6, 7 OE GYN CLINIC (ducted) Notes & Options: 1 Nominal cooling capacities are based on indoor coil EAT of 80/67°F (DB/WB), outdoor of 95°F (DB) 2 Nominal heating capacities are based on indoor coil EAT of 70°F (DB), outdoor of 43°F (WB) CONTACT: 3 See outdoor unit schedule for outdoor ambient conditions, connected capacity, and other factors 4 See schematic piping/control diagram for indication of required indoor unit remote controllers, system MIKE MCKENNA controllers, and integration devices. 5 Full demand corrected capacity includes de-rate associated with indoor vs. outdoor connected capacity indicated on outdoor unit schedule for associated system. Partial corrected capacity assumes sufficient i> diversity exists such that the connected capacity de-rate does not apply. It is the designees 1- V. f7 responsibility to ensure "Diamond System Builder" is set in the appropriate output capacity setting (full �� , t .,... demand/partial demand) prior to generating this schedule. , I+ ' 6 It is recommended to always base heating corrected capacity on full demand. K .F i 7 Provide FBM sores return air filter box with MERV 7 filters " !� i q .�p�41928p� - ,. ., �%4'I6,, .. '.' �kr.NF,II. LOSSNAY ENERGY RECOVERY VENTILATOR SCHEDULE Nominal Recovery Effectiveness (Extra High a- Fan Speed) ' Interlocked or M-Net OSA Airflow EXH Airflow Max ESP Temperature Enthalpy Enthalpy MCA/ Notes / { Lossnay Tag Model Number Stand Alone Address Core Type (cfm) (cfm) (INWG) Recovery Cooling Heating WEIGHT LBS Voltage/ Phase MOCP Options 18-201 Fixed Permeable " ° ° 208-230V/1- j PKUJCG I NUMISM: HRV-1 LGH-F600RX5-E Interocked 5 600 520 0.80 67.0% 50.0% 64.0% 140 3.6/15 1, 2, 3 , Cross Plate phase 0404,, % REVISIONS: Notes & Options: .m.__, f se 1 Max external static pressure is at airflow listed with fan set on extra high speed. 2 See schematic piping/control diagram for indication of required losnay local remote controller(stand alone operation) and M- .=� 02-20-18 PERMIT / BID SET 3 Washable factory standard pre-filter on return and 0/A intake side of cross plate core. , f M 1VRF HEAT RECOVERY BRANCH CIRCUIT CONTROLLER0 DUCTWORK INSULATION Power Cooling Power Heating SERVICE DUCT LOCATION/ TYPE FIBERGLASS INSULATION TYPE THICKNESS NOTES Type (double/ Connected Voltage/ 208V/230V 208V/230V System Tag Tag Reference M-Net Address Model Number Main / Sub) Number of Ports Capacity to BC WEIGHT LBS Phase (kW) (kW) MCA 208/230 Notes / Options OUTSIDE BUILDING ENVELOPE CMB-P106NU- 208/230V/1- s GALVANIZED SHEETMETAL DUCT W/ System 1 BC-1 52 69,000.0 80 0 086 0.04 0.52/0.47 1 2 INTERNAL INSUL TO HAVE MIN. R-8 G1 Single 6 phase . , HRV EXHAUST OUTSIDE BUILDING OUTSIDE BUILDING ENVELOPE (ROOF) (EXTERNAL INSULATION W/ METAL 2" EXTERIOR THERMAL PERFORMANCE INSIDE BUILDING ENVELOPE Notes & Options: CELING PLENUM INSTALLATION: LOW DUCT WRAP WITH MYLAR VAPOR 1 Include Diamondback Ball Valves BV-Series, 700PSIG working pressure, full port, 410A rated. CONCEALED SUPPLY AIR PRESSURE SUPPLY FROM FAN COIL TO GRDs BARRIER 1" 2 Connected Capacity to BC should not exceed 189,000 BTU/h for double BCs and 126,000 BTU/h for Sub BCs. RETURN AIR FROM GRD TO FAN COIL N/A N/A DUCT IN CONDITIONED SPACE OR SHEET TITLE: CEILING INSULATION SPECIFICATION: KNAUF, CERTAINTEED, OWENSCHORNING, OR APPROVED EQUAL SCHEDULES NOTES: 1. NO EXPOSED DUCT LINER OR FIBERLASS ALLOWED IN SUPPLY AIR STREAM 1 . 2. ALL INSULATION SHALL BE INSTALLED PER SMACNA GUILDELINES, AND MFG. INSTALLATION INSTRUCTIONS HVAC 1 3. DUCTWORK INSULATION SHALL BE INSTALLED AS INDICATED ON DRAWINGS AND AS REQUIRED PER CODE VENTILATION SCHEDULE I ELECTRIC HEATER SCHEDULE OSA CFM TOTAL TOTAL CFM EQUIP. CONTROL ELECTRICAL AREA SQ ROOM NO. CFM/ CFM/SQ OSA @ OSA ACH TOTAL ACH PRESSURE FC NO. ROOM NUMBER NAME FT HEIGHT PEOPLE PERSON FT 80% EFF PER FGI REQ. PER PER FGI CFM ACH EXHAUST RELATIONSHIP NOTES TAG LOCATION MFG/MODEL# WA I IS ORIENTATION OPTION V/PH REMARKS FGI PER FGI PER FGI EH-1 106 DIRTY KING/PAW12075 750 WALL MOUNT REMOTE 120V/ 1PH 1 FC-3 101 HALL 310 7.9 0.06 23 NR 2 EH-2 107 RESTROOM KING/PAW1205 500 WALL MOUNT REMOTE 120V/ 1PH 2 FC-4 102 EXAM -1 125 7.9 2 2 33 6 99 NR 1 FC-4 103 EXAM -2 125 7.9 2 2 33 6 99 NR 1 FC-4 104 EXAM 6 154 7.9 3 2 41 6 122 NR 1 PJC NOTES: 1. COORDINATE LOCATION OF UNIT WITH ARCHITECTURAL FEATURES AND ALL OTHER TRADES FC-4 105 CLEAN 67 7.9 2 18 4 35 POS 1 PROJECT ARCHITECT: FC-4 106 DIRTY 73 7.9 2 19 10 96 NEG 1 PJC FC-4 107 RESTROOM 50 7.9 10 66 NEG 1 DRAWN BY: FC-21 109EXAM -3 ULTRASOUND 1281 7.9 3 2 34 6 93 NR 1 ELECTRIC DUCT HEATER SCHEDULE FC-1 109 EXAM -3 118 7.9 2 2 31 6 93 NR 1 PJC FC-1 110 EXAM -4 102 7.9 2 2 27 6 81 NR 1 CHECKED BY: PRESSURE ELECTRICAL FC-1 111 STORAGE 40 7.9 2 11 6 32 NR 1 FC-3 112 EXAM -5 136 7.9 2 2 36 6 107 NR 1 TAG LOCATION MFG / MODEL KW SIZE DROP (IN. W.C.) V PH REMARKS JANUARY 12, 2018 FC-3 113 MA'S/RN'S 145 7.9 5 5 0.06 40 0 NR 2 DH-1 HRV-1 OSA SUPPLY DUCT INDEECO/ QUZ 3.5 12"x 8" 0.025 208 3 1, 2, 3 DATE FC-3 114 DOCTORS 140 7.9 4 5 0.06 33 0 NR 2 - TOTALS 1,713 25 97 281 162 COMPUTER FILE NAME NOTES: 1. INDEECO CONTROL OPTION 'K'WITH SCR POWER CONTROLLER. 2. PROVIDE WITH BUILT-IN DISCONNECT SWITCHES. NOTE: 1.VENTLATIONRATES PER ASHRAM ACHE STD 170-2013 3. PROVIDE DISCHARGE AIR SENSOR SET TO 65 DEG F. M 1 2.VENTILATION RATES PER 2015 I MC CHAPTER 4 7 + COMMIT 2018 CARLETn ARCHITECTS, PA. + I y=r CARLETTI ARCHITECTS P.S. architecture,planning,interior design PLUMBING FIXTURE SCHEDULE 116 EAST FIR STREET SUITE A HVAC PIPING INSULATION SCHEDULE LOCAL CONNECTIONS MOUNT VERNON, WA. 98273 TAG DESCRIPTION W V HW CW Phone: 360 424-0394 Fax: 1360) 424-5726 INSULATION MINIMUM INSULATION THICKNESS LAVATORY (ADA) -WALL HUNG, AMERICAN STANDARD COMRADE 0124.131,VITREOUS CHINA, CHICAGO FAUCET SYSTEM FLUID OPERATING INSULATION TYPE CONDUCTIVITY MEAN TEMP 2200-2805ABCP SINGLE HANDLE, 1/2 GPM LAMINAR FLOW, SINGLE SCREWDRIVER STOPS & SUPPLIES, 1-1/4"CP, 17 GA TEMP (BTU/IN)/(HR-FT2-F) (°F) 1.5" AND LESS 2"AND LESS REMARK L1 CHROME PLATED P-TRAP, PLUMBEREX TRAP GEAR SERIES P-TRAP!H&C COVERS, PROVIDE WITH LEONARD 270 2" 1-1/2" 1/2" 1/2" PERMIT - BID SET THAN 8" THERMOSTATIC MIXING VALVE. SINK-ONE COMPARTMENT(STAINLESS STEEL COUNTER MOUNT) ELKAY LRADQ191965PD, 6-1/2" DEPTH, ELKAY GRID Our difference CONDENSATE DRAINAGE INSIDE BUILDING 45-55 FIBERGLASS W! ALL SERVICE JACKET 0.24-0.27 N/A 0.5 0.5 1 is engineered. DRAIN MODEL LKPDVR18B, CHICAGO 50-GN8AE35-317XKA6, 1.5 GPM- 8" GOOSENECK SPOUT WITH LAMINAR FLOW H VRV SYSTEM REFRIGERANT PIPING FROM FLEXIBLE ELASTOMERIC INSULATION Si SPOUT END, WRISTBLADE LEVER HANDLES RED & BLUE HOT& COLD DISIGNATION , CERAMIC DISC CARTRIDGES, GRID 2" 1-1/2" 1/2" 1/2" ; www.harrisgroup.com CU TO BS CONTROLLER (ASTM C-534 (ARMAFLEX OR EQUAL) 0.24-0.27 75 0.75 1 1 DRAIN, SCREWDRIVER STOPS &SUPPLIES, 17 GA CHROME PLATED P-TRAP, PLUMBEREX HANDY-SHIELD MAXX SERIES P-TRAP AND H&C SUPPLY COVERS OR EQUAL Harris Group VRV SYSTEM REFRIGERANT PIPING FROM FLEXIBLE ELASTOMERIC INSULATION PROJECT NO: 0070412.00 0.24-0.27 75 0.75 1 12 BS CONTROLLER TO FAN COIL (ASTM C-534) (ARMAFLEX OR EQUAL) SINK (SINGLE COMPARTMENT) -JUST MODEL SL-2125-A-GR, 25"X21" NOM. MAX. 8" DEEP, CENTER DRAIN, CHICAGO S2 201-AGN8AE3-317XKCP GOOSENECK SPOUT WITH LAMINAR FLOW SPOUT END, WRISTBLADE LEVER HANDLES, 2" 1-1l2" 1/2" 1!2" CERAMIC DISC CARTRIDGES, GRID DRAIN, SCREWDRIVER STOPS &SUPPLIES, 17 GA CHROME PLATED P-TRAP, NOTES: 1. INSULATION TO BE FIELD APPLIED. EXTERIOR INSULATION TO HAVE STANDAR UV RESITANT WHITE PVC JACKET PLUMBEREX HANDY-SHIELD MAXX SERIES P-TRAP AND H&C SUPPLY COVERS OR EQUAL. 2. LINESETS USED IN CONCEALED LOCATION TO HAVE FACTORY APPLIED INSULATION WITH FIELD APPLIED PATCH! REPAIR WATER CLOSET-(FLOOR MOUNT FLUSH VALVE)AMERICAN STANDARD MADERA 3461.660 , ADA COMPLIANT, 1.6 GPF, ISLAND HOSPITAL AS NEEDED FOR CONNECTIONS WC1 VITREOUS CHINA, MANUAL FLUSHOMTER SLOAN ROYAL 111, BEMIS 1955CT OPEN FRONT SEAT, SCREWDRIVER STOP 3" 2" -- 1/2" & SUPPLY, NO-SEEP WAX RING W/SLEEVE, CLOSET BOLTS, NUTS&WASHERS PRIMARY CARE CLINIC EXPANSION AND IMPROVEMENTS OB GYN CLINIC PLUMBING PIPING SCHEDULE CONTACT: SERVICE LOCATION SIZE PIPE PIPE MATERIAL FITTINGS JOINTS WORKING TEST NOTES MIKE MCKENNA STANDARD PRESSURE PRESSURE DOMESTIC COLD WATER, DOMESTIC ABOVE GRADE 1/2" -3" COPPER TYPE L HARD DRAWN ASTM B88 WROUGHT COPPER WATER SAFE 70 PSIG 100 PSIG HOT WATER, HOT WATER RECIRC. SOLDER BCUP V t, 47 ABOVE GRADE 1-1/4" - 6" NO-HUB CAST IRON CISPS 301 NO-HUB CAST IRON NO-HUB AMBIENT 5 PSIG STANDARD DUN `, d I COUPLINGS at, rb 1-1/4" -6" NO-HUB CAST IRON CISPS 301 NO-HUB CAST IRON NO-HUB AMBIENT SPSIG STANDARD DUTY COUPLINGS 0. i SANITARY WASTE & VENT BELOW GRADE 1-1/4" -6" PVC - SCHEDULE 40 SOLID CORE ASTM D2665 PVC SCHEDULE 40 (SOLID CORE) SOLVENT WELD AMBIENT 5 PSIG 4412410 `r I.Wit 1-1/4" -6" ABS -SCHED 40 (FOAM CORE) ASTM D2661 ABS - SCHED 40 (FOAM CORE) SOLVENT WELD AMBIENT 5 PSIG CONDENSATE DRAINAGE ABOVE GRADE 1/2" - 2" COPPER TYPE L HARD DRAWN ASTM B88 WROUGHT COPPER WATER SAFE 70 PSIG 100 PSIG SOLDER BCUP 3/8" - 1/2" COPPER TYPE ANNEALED ASTM B88 WROUGHT COPPER WATER SAFE 70 PSIG 100 PSIG 18-201 ABOVE GRADE SOLDER BCUP TRAP PRIMER BELOW GRADE - I KUJtU I NUMCStK: 3/8" - 1/2" PEX-A ASTM F876 ASTM LEAD FREE BRASS UPONOR PRO- 70 PSIG 100 PSIG F877 PEX REVISIONS: NOTE: CONTRACTOR TO PROVIDE ANY OF THE INDICATED PIPING OPTIONSSHOWN ABOVE. u y, 02-20-18 PERMIT / BID SET ,;. MECHANICAL PIPING SCHEDULE SERVICE LOCATION SIZE PIPE PIPE MAIL FITTINGS JOINTS JOINT WORKING TEST STANDARD STANDARD PRESSURE PRESSURE VRF SYSTEM (DX) FROM CU TO BC 1-1/2" AND TYPE L OR K ASTM B280 WROUGHT COPPER SILVER BRAZED AWS A5.8 450 PSI 550 PSI REFRIGERATION (R-410A) CONTROLLER BELOW COPPER, ACR TYPE LORK VRF SYSTEM (DX) FROM BC CONTROLLER TO 1" AND COPPER, ACR, ASTM B280 NO FITTINGS COMPRESSION NA 450 PSI 550 PSI 1. REFRIGERATION (R-410A) FAN COIL BELOW ANNEALED COILS NOTE: ALL PIPING AND INSTALLATION SHALL MEET THE REQUIREMENTS OF CHAPTER 12 OF THE 2015 SMC. tt SHEET TITLE: i SCHEDULES PLUMBING - PIPING ) PJC PROJECT ARCHITECT: 1 PJC DRAWN BT: PJC CHECKED BY: JANUARY 12, 2018 DATE COMPUTER PILE NAME V 1 1 2 COPYRIGHT 2018 CARLETTI ARCHITECTS, P.S. + Mechanical Summary MECH-SUM Economizer Exceptions MECH-ECONO + 2015 Washington State Energy Code Compliance Forms for Commercial Butdtngs including R2&RS over 3 stories and all R1 Revised January 2017 2015 Washington State Energy Code Compliance Forms for Commercial Buidings including R2&R3 over 3 stories and all R1 Revised January 2017 Project Information Project Title: 1-This title will copy onto ether forms Date 2/16/2018 Project Title: Fit this ale.out en MEG-FSUM Date 2/16/2018 /tV Applicant Information. Protidecontact information tor individuatwho canrespondto For Building'Dept. Use For Building Ciept. Use System Checksums inquiries about compliance form information provided. All cooling systems shall be configured to provide air economizer operation,regardless of By HARRIS GROUP INC. system HARPoSGROt#rINC sysfemtapactty,for new constmdklnand mechanical systematteratbns.Vanousoicteptionsta this requirement are available Identify all systems that an economizer exceptionwiltbe applied VRF Variable Refrigerant Flow Company Address: 20201 CEDAR VALLEY RD,SUITE 120,LYNNWOOD,WA to and additional information as noted below.. COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK TEMPERATURES Applicant Name: fSCfiARDHAWWNSON Peaked at Time: Mo/Hr: 7/14 Mo/Hr:7/15 Mo/Hr: Heating Design Cooling Heating AppicantPhone: 425-774-3829 Economizer ECONOMIZER EXCEPTIONS -NEW CONSTRUCTION AND ADDITIONS Lighting+ Outside Air: OADB/WB/HR: 81/68/82 OADB:82 OADB: 15 SADB 56.3 78.8 Exception Exp 1 Cooling equipmentserving spacesthatare provided witha dedicated System ID Equipment Ra Plenum 83.1 62,8 l� Project Description ❑ New Building ❑Building Addition 2 Tenantlnproverrent ❑System ftetrofit ❑No System Changes outdoor air system(DOAS)per C403.6.Spaces served shall have year- Loads(Wisf) Space Plenum Net Percent Space Percent Space Peak Coil Peak Percent Return 75.0 70,0 CARLETTI ARCHITECTS P.S. Briefly describe mechanica<systems n - r Summary round design coding loads from lights and equipment less than 5 w atts per Sens.+Lat. Sens.+Lat Total Of Total!; Sensible Of Total Space Sens Tot Sens Of Total Ret/OA 75.6 64.2 , Beflyescibovidatl HVAC THISPROJECTCONSIS,SOFADDINGANEWVRFSYSTEMTOAPREVIOUSLYCONDITIONEDCLINICSPACEAHEATRECOVERY square foot, Btu/h Btu/h Btu/h (%)I Btu/h (%) Btu/h Btu/h (%) Fn MtrTD 0.0 0.0 architecture,planning,interior design VENILATOIN SYSTEM-THOUGH NOT REQUI RED FOR THIS PROJECT-WILLPROVIDEVENi1LATION AIR TO THE OCCUPIED AREAS.NO _ Envelope Loads Envelope Loads Fn BldTD 0.1 0.0 ❑Total Bldg Performance(-1.BP} ECONOMIZERS WILL BE.USED PER EXCEPTION 7 OF SECTION 403.3 OF THE 2015 MEC. ALSO INCLUDED IN THIS WORK IS THE ADDITION Skylite Solar 0 0 0 0 0 0 Skylite Solar 0 0 0.00 Fn Frict 0.3 0.0 OF A ELECTRIC HEATERS FOR RESTROOM AND DIRTYROOM. DUCTWORK,DUCT INSULATION,GRILLES/REGISTERS/DIFFUSERS, Skylite Cond 0 0 0 0; 0 0 Skylite Cond 0 0 0.00 116 EAST FIR STREET This path includes all mandatory CONDENSER WATER PIPE,ANDPIPEINSULATION. Roof Cond 0 3,354 3,354 8 0 0 Roof Cond 0 •3,900 16.62 SUITE A provisions per C40120ption 2. Glass Solar 0 0 0 0! 0 0 Glass Solar 0 0 0.00 AIRFLOWS MECH-SUM,MECH-CHK,andC407 PLUMBING:EXISTING SANITARY,HOT/COLD(RECIRCWATER LINES WILL BEUTILIZEASNEW PIPINGIS CONNECTED AS NEEDED TO SERVE Exlass/Door Cond 0 0 0 0' 0 0 Glass/Door Cond 0 0 0.00 P 2 SiSin glezone units rYor package ferns with dehumidificationthat affect System ID Wall Cond 0 0 0 0- 0 0 Wall Cond 0 0 0.00 Cooling Heating MOUNT VERNON WA. 98273 EnergyAnalysis forms requited NEW FIXTURES.SELECT EXISTING PIPING WILLEE CAPPEDAS SHOWN NO NEW WATER HEATERSARE INCLUDED other systems such that air economizer w ould increase energy Partition/Door 0 0 0 0 0 Partition/Door 0 0 ago Diffuser 1,523 1,523 consumption. Floor 0 0 0' 0.00 0 Floor 0 0 0.00 Terminal 1,523 1,523 ❑ Load calculation summary 0 MECH-LOAD-CALC Form. Refer to Section Adjacent Floor 0.00 0.00 0.00 0.001 0.00 0.00 Adjacent Floor 0.00 0.00 0.00 Main Fan 1,523 1,523 Phone: 360 424-0394 Design Load Calculations Provide design load calculetiansfor all mechanical systemsand equipment servingthe building heating,cooling orr C403.3 for Infiltration 3,227 3,227 7! 1,394 4 Infiltration -10,971 -10,971 46.76 Sec Fan 0 0 Fax: 360, 424-5726 ventilating needs.If a load ea/nu/albs summaryis provided with the permit documents that Ind udes all applicable descriptions of Exp 3 High efficiency single zone unitaryorpackagedsystems Equipment System ID Sub Total==> 3,227 3,354 6,582 15' 1,394 4 Sub Total==> -10,971 -14,871 63.38 Nom Vent 418 418 compiianceinform3ion then the MECH-LOAD-CALC form is not required economizer cooling efficiencyshall be better than the WSEC requiredninimum - AHU Vent 418 418 provisions and efficiency by at least 64%in Climate Zone 4C and 59%in Climate Zone 5B Internal Loads Internal Loads Infil 180 180 Q Mechanical Hans ❑ MECH-EQ Forms (TBD) exceptions. For per Table C403.3, Lights 4,209 1,052 5,262 12 i 4,209 13 Lights 0 0 0.00 MinStop/Rh 1,063 1,063 PERMIT - BID SET Mechanical Schedules Indicate refer • People 11,250 0 11,250 261 6,250 20 People 0 0 0.00 Return 1,505 1,505 Indicate location of equipment compliance information If provided on plans then MECH EQforms are not required, to Section Misc 8,410 0 8,410 20... 8,410 27 Misc 0 0 0.00 Exhaust 401 401 however,include on plans all applicablecompliance information listed inMECH-EQtables. C503;4 and Exp4 Equipment that provides hydronic chilled water for chilled beamsand System ID Sub Total==> 23,869 1,052 24,921 58 18,869 60 Sub Total 0 0 0.00 Rm Exh 197 197 TableC503.4. chilled ceiling systems that is served by a w atereconom¢er system per OUr difference C403.3.4 in lieu of air economizer. Auxiliary 0 0 I ,i ❑ DOAS is required per C403 6 effectiveJuly 1,2017(office,retail,education,library and fie station occupancies) Ceiling Load 4,407 -4,407 0 0 4,381 14 Ceiling Load -3,900 0 0.00 Leakage Dwn 0 0 �=: is engineered. Ventilation Load 0 0 4,053 9: 0 0 Ventilation Load 0 -8,592 36.62 Leakage Ups 0 0 S' All occupied conditioned areas shall be servedbya DOAS that delivers requiredventilation air in a manner that does Adj Air Trans Heat 0 0 0 0 0 Adj Air Trans Heat 0 0 0 9 P � , www.harrisgroup.com not require space conditioning fan operation.Space conditioning fans cycled off when no heating or cooling is required. Exp 5 Water-source heat pumps wfthheat recovery Heat pump efficiency shell System ID Dehumid.Ov Sizing 0 01 OvlUndr Sizing 0 0 0.00 be'15%betterthan WSEC required minimum efficiency.Provide at Ovlundr Sizing 6,932 6,932 16 6,880 22 Exhaust Heat 0 0.00 Dedicated Outdoor Air ❑ p P ( p y ENGINEERING CKS Ventilation provided via natural ventilation. er2015 WIC in lieu of DOAS C4036,Exception l) minimum 60%air economizer.Energy recovery to preheat OSA shall Exhaust Heat 0 0 Oil OA Preheat Diff. 0 0.00 Ventilation and ace conditioningprovided bya HEVAVs stem per C.403.7 in lieu of WAS C403.6, Exception 2) have at least effectiveness.Additional systems uirementsa -- System Sup.Fan Heat 632 1 : RA Preheat Diff. 0 0"DO Cooling Heating PROJECT N0: 0070412.00 Requirements and ❑ P y p ( p Ret.Fan Heat 0 0 0 Additional Reheat 0 0,00 %OA 27.5 27.5 Duct Heat Pkup 0 0 0 cfm/ft2 0.89 0.89 High Efficiency VAV E] DOAS included in project although not required(occupancy notoffice,retail,education,library orfire station) Exp 6 Cooling equipment seivirig GroupRoccupar,cies Perunit limit is Equipment Cooling Underflr Sup Ht Pkup 0 0 Underflr Sup HtPkup 0 0.00 cfm/ton 423.79 less than 20,000 Btu/h cooling capacity for equipment instated System ID Capacity Supply Air Leakage 0 0 0;; Supply Air Leakage 0 0.00 ft°/ton 476.72 Alternate outdoors or in a mech room adjacent to the outdoors.For coolingLocation ❑ DOAS related allow antes included in larded: 1 (Bluth) Btu/heft• 25.17 -14.45 equipment installed in other locations the unit limit is less than i Grand Total==> 38,435 0 43,120 100.00 31,524 100.00 Grand Total==> -14,871 -23,463 100.00 No.People 25 ❑ Prescriptive vertical fenestration maximum area allow ance increased to 40%per C402.4.1.4w ith 100%of 54,000 Btu/h.Efficiency shalt be45%better than VVSEC required conditioned floor area in building served by DOAS. minimum efficiency. COOLING COIL SELECTION AREAS HEATING COIL SELECTION ISLAND HOSPITAL ❑ Exception to air economizer perC4033 Exception 1,include MECH-ECONO form.. Total Capacity Sens Cap. Coil Airflow Enter DB/WB/HR Leave DB/WB/HR Gross Total Glass CapacityCoil Airflow Ent Lvg PRIMARY CARE CLINIC Exp 7 Variable refrigerant flow(VRF)systems with energyrecovary.Outdoor Outdoor Unit Cooling ton MBh MBh cfm °F °F or/lb °F °F gr/Ib ft2 (%) MBh cfm °F °F 0 Project includes HVAC air distribution systems that provide heating and/or cooling unit shall be a reverse-cycle heat pump w.ith variable speed System ID Capacity Main Clg 3.6 43.1 33.1 1,523 76.0 63.6 68.6 56.3 54.1 59.3 Floor 1,713 Main Htg -24.8 1,523 64.2 78.8 EXPANSION AND IMPROVEMENTS compressor(s)and condenser fans) Outdoor unit cooling capacity shall (Btu/h) Aux Clg 0,0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Part 0 Aux Htg 0.0 0 0.0 0.0 OB GYN CLINIC if yes,provides MECH-FANSYS-SUM form. be not less than 65,000 Btulh.Energy recovery to preheat outdoor air SYS-1 72,000 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Int Door 0 Preheat 0.0 0 0.0 0.0 Fan power ❑ For one ormore systems,the total fan motor nameplate hp of at fans in HVAC system exceeds 5hp. small.have at least 50"/o rated effectiveness.System shalroe capable of 0 providing simultaneous heating and cooling by tranfernRoofng recovered Total 3.6 43.1 1,713 0 0 Humidlf 0.0 0 0.0 0.0 If yes,provide a seperateMECH-FANSYSform foreach HVAC system exceeding the 5 tiorsepower threshold energy fromzone(s)in cooling niiate to otherzone(s)that are in heating Wall 0 0 0 Opt Vent 0.0 0 0.0 0.0 Refer to Section C403.2.11 and MECH-FANSYS-DO.0 for requirements andexceptians. mode. Ext Door 0 0 0 Total -24.8 ❑ hydronic chilled water ❑ Water-loop heat pump Q No hydronic systems SEER,MR,& HVAC Hydronic Systems Exp 8 coolingnt codentserving encyshtrolled better Growth Environments. System ID ❑ Hy drohit heating w alter ❑ Geothermal Equipment coding effxiengyshai be better than WSC-C required JEER Project Name: Island Hospital-OB GYN TRACE®700 v6.3.3 calculated at 11:08 AM on 02/13/2018 minimum efficiency by at least20%.Not eligible:unitary and applied heat Dataset Name: Island Hospital OB GYN.trc Alternative-1 System Checksums Report Page 1 of 1 CONTACT: ❑ pumps. MIKE MCKENNA C406.2 More efficient HVACequipment and fan systems Requires 90%of heating and cooling capacityto be equipment listed in tables C403.2.3(1)-(9)or air-to-water heat pumps and heatreeoverychillers Ail equipment listed in tables C40a2.3(1)-(7)must be 15%more efficientthan Lighting+ minimum requirements.All standalone supply,return,and exhaust fans over 1hp must have FEQa_71 and must be Exp 9 Cooling equipment with energy recovery.Spaces served shall have year- round destgn cooling loads from lights and equipment greater than 5 System ID Equipment C406 Additional Efficiency w atts persquarefoot,Energy recovery system shall utilize recovered Loads(Wlsf) ❑ C406.6 Dedicated outdoor air system(OCAS) energy for on-site space heating or preheating of service hot water. V. r. Options Requires 90%of conditioned floor area lobe servedb a DOASper C403.6 that delivers required ventilation airing +� p e4 Y Qu recovered e calculationsd to for on s officialheat that demonstrate the amount of mannerthatdoesnotrequirespaceconditioningfanoperation. recovered energy used for or-sieheating purposes isequwalenttothe �� � ❑ C406.7 Reduced energy in servicewater heating annual energy that wouldbe saved by the coding sy stem withair I_ Requires 90%offoor area beinoccupancytypeslistedinC406:71 and that 60%ofannual'hot water energy use be aconomizerperC403.3. } provided by heat pump,waste heat recoveryor solar water-heating systems. Mechanical Summa pg. 2 MECH-SUM 59a6 •' sEnergy g gJanuary Mechanical Fan System Power Allowance MECH-FANSYS-SUM �' 2015 VYashin ton State CvdaCo knee Forms for Commercial Butdn s including R2&R3.over 3 stories and ail R1 Revised 2017 on. Equipment Type(s) 2015 Washington State Energy Code Compliance Forms for Gam itrcial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 ❑ Hot w ater heating tank(s) ❑ Instantaneous Q No service w atersystems Project Title: Fill this line out anMECH-SUM Date 2/16/2018 For Butane Dept Use Service Water Heating Heat exchange fromspace heat boter or ❑ Dedicated boiler ❑ centralhot w ater/steam Systems Distribution Type(s) ❑ Circulation System ❑ On-demand 18-201 Commissioning Commissioning is required for: HVAC Air Distribution System Schedule - PNUJtt; I NUMCtK: List all HVAC systems that have the capabilityto provide heating and/or cooling to the spaces they serve" ❑ Wchanical systems per CA08.2 ❑ Service w ater heating systems perC408.4 If required,commissioning shell be performed for all applicable systems regardless ofEndividual equipment capacity Fan Pow er REVISIONS: System or System Total Cale uatiu: Exceptions to commissioning requirements: Primary Supply Speed Control Description Nameplate HP Rea tweet ri❑ Total output capacity of all mechanical space conditioning systems in the building do not exceed 240,000 Btu/h Fan ID (Note 1) (Note 2) ,Note 3) (Nate 4) 02-20-18 PERMIT / BID SET coding or300,000 Btu/h heating.Mechanical systems commissioning not required. SYS-1 CV 0.62 No 1-1 Capacity of largest service waterheatng system in building does not exceed 200,000 Btulh.Servicew ater heating systems couunlsskming not.required. Low Energy and Semi-Heated Spaces (Note 6 and 7) Peak Space Heating Cooling Conditioning Space Area Served, Capacity, Bt.,` Capacity Btu/h Capacity, Compliance Type Location in Ran(s) Space(s)Served square feet (Note 4) (Note 5) Btulh-sf Bieck Notes ' Note4-Provi de total installed heating oulputcapacity of.systems serving LowEnergy or Semi-Heated space(s)in btuh. Note 1-Constant Volume(Ctr),Variable Air Volume(VAV),or Hospital/Lab CV system thatqualifies for VA Vbudget per C403 2.11.1 Exceptign 1. Note 5-Provide total installed cooling capacity of system serving LowEnergyspace(s)in Btu/h.Notallowed for semi-heated spaces Enter 0 ifnocooling. Single zone VAV systems shall comply as CV Note 6-Refer to Section C402.1.1 Low Energy Building.'Mailed peak space conditioning capacity heating or cooling.may not exceed 3.4 Btu/h'sf. Note 2-Describe system type and listali fans(or groups of fans)associated with the deliveryand removal of conditioned air bythe system Include Note 7-Refer to Section C402 1.1.1 andSemi-Heated Space definition in Chapter 2 Total heating output capacitymayno exceed 8Btu/htst: Onysystems wtthott all supply return/relief,exhaust and exhausthoods(>1 hp),make-up air,dedicated outside air(DOAS);booster fans.and series fan-powered electric resistance heating and no cooling are eligible for the wall insulation exception under seam-heated. terminals.VAV parallel fan-powered terminals and economizer relief fans do not need to be includedifthe fans do not operate at peak conditions. Note 3-Enter the total nameplate hp of all fans associated with the deliveryan d removal of conditioned air bythe system. SHEET TITLE: Note 4-This form automaticallyidentifres whether a MECH-FANSYS form is required to demonstrate compliance with the fan power allowance(Yes), • or this information is not required because the system has a combined total nameplate motor hp that is 5 hp or less(No) ENERGY CODE I 1 PJC PROJECT ARCHITECT: PJC DRAWN BY: PJC CHECKED BY: ,, JANUARY 121 2019 DATE g COMPUTER PILE NAME M /I 1 3 „[ , .„ + COPYRIGHT 2016 CARLeTTt ARCHrreCTe, Pa + A CARLETTI ARCHITECTS P.S. architecture,planning,interior design 116 EAST FIR STREET SUITE A MOUNT VERNON, WA. 98273 Phone: (360) 424-0394 Fax: 360 424-5726 PERMIT - BID SET Our difference is engineered. www.harrisgroup.corn Harris Group PROJECT NO: 0070412.00 i ISLAND HOSPITAL (E) W DEMO PRIMARY CARE CLINIC & CAP EXPANSION AND IMPROVEMENTS 1/2" HWUP 1/2" H&C DN - (E)1/2" H&C UP OB GYN CLINIC -------7 2 WUP S 112" H&CUP 1/2" CW UP •yC; - I ,. 1 (E)1-1/2"W DEMO& CAP (PING UP THRU ROOF 2"W DN-N > ( S1 -.__DEMO &CAP / 2' W DN 1 iv 6 RL ________ ! __ S / I REF. PIPING TOFC'S 1-1/4" HWC - - - - 1 k- 2"W UP I �C 1I Cl' �(2) PIPES EA. rIT 1° cw-� I (E)1/�" H&C UP �iTOR. I !! ' ( E &CAP i �� 1 '- d , vz° H&c ON a CONTACT: 1 _ / 111 , DOCTORS i 12 I EXAM HALL s1 I MIKE MCKENNA �— -N� of R i I 114 101 11 L I I CU1 I j 112 I �2::V - -- R 2"V I (E)H:C I 1 _ J1 f ---- — EXAM-1 DE O&CAP 2:,V 2 W D 4" ONNECTY V. (E)H&C / I TAtLFdE� E S C I(E)3/4" HW I - — lop/ Ito ' DEMO& CAP AM 4 / - - I , 1 10� ?eV R 1/2" HW (E)3/4"Th 1C J}b�1 - - F S fE' W DEMO 3/4" CONDENSATE I 1 L • ri 4.C+ 1 H UP ��3 SAP (E)4:,W41111 TYPICAL �� - 1!2" CW 1/2" HW DEMO 4"W�i \I 1 a+ ► - ,�, - -fir - - 1/2�&C DN I I 2 I— 10 -�' _ Y / I 1 . DEMO&CAP &CAP &1/ F DEMO r) 3" RL DN Ii FC-1 1 S1 't -�' 1 FC-4 J {p (--1-1 ))) L 1/2' H&C UP j 1 1 S1 I I I R 2"WUP 1/2" H&C DN-t —� MA'S/RN'S ,L 2"VDN 1 -I I j2VUP (E)1-1/4" HWC i 3" RL� 2"W DNJ --+- 1� 113 3 _ I I . E)1 WC- ' 1 4 RL 1/2" H&C DN c, i : —1 C 1 - - w-- -- --. ___ J PKUJt(aI NUMEStN: 1/2" H&C UP . - T .: I_ 2' DN - • f4' RL s1 I g +_--FC3t EXAM-2 (E)VENT UP DEMO 1 " *40. EXAM-3 h X 103 / REVISIONS: ♦ I CAP IN PLACE i k� • 1 t 11" 109 2 v HALL / _ t '"It c R 02-20-18 PERMIT / BID SET 1 4,:W� (E)3" RL UP �^ 1 lEiNlr 1 ♦ 4rilf )‘3/4'7""H-& 1 (E)1-1/4" HWC IA 1A ® P - — I I - - i 1 - - _ c2H&CDN " HBIr'1 DEMO & CAP 1 1/2'-4-1&C UP SI �jT1" CW , IIQ-p _ 1selow L FC-2 J 1 'Ili Il - - - - __ - 2"WUP I 6 5 I 'W DN I 7 VESTI �- 1 (E)1-1/2' UP�.0 41/2" H& C I L S2 \'I I _____ 4) I 2�:V • DEMO CAP �1/22'W UP P I il SCALE ( �� M OD (E) 4"WIUP /� �/ UP' H&C 11 - - ULTRASOUND I I 1/2 H&C -1--- -- 1 . 77-1-116" 1 DEMO& CAPJ '� I I -- - - -I- - 7 DIRTY -J- - / `�' 2"WDN I 2�:�_ 106 CLEAN 1/2" H&C DN 0 IV 2"WUP I 2"W Dig105 EXAM 6 �I W DN (' I I I 104 0 � I , (E)4"WUP -O 1/2" H&C DN it - -- -� 2"W 11 I PIPE THRU II R'R 2"V I f4 W _44 WALL TO LAV 1 107 ® C ��`1 I 1/2' HW& Tl L1 I r. SHEET TITLE: CW UP (L&S)� I I WC -�—(E)1-1/2"WUP ® 2"V�L -3 VTR 1 L I I DEMO&CAP I- , _lit-l- r ��' :1 3 W DN it 11 L_. ..-- -T___-- —}-1 � - -+ - -+� FLOOR PLANS Ti ii '.',???� lT=ZIl:_.r=r1L "1Z11'1 Z2 __-_-- -__-_- 1"CUP �� 1 C I.E. 144.5' L E. 145.XX PIPING 6" RL- (E)4"W-----' I PLAN PLAN NORTH NORTH LOWER LEVEL FLOOR PLAN - PIPING PJC EL) G © MAIN LEVEL FLOOR PLAN - PIPINGP PROJECT ARCHITECT: 0 2' 4' 8' o r a' 6' PJC DRAWN BY: SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" PJC CHECKED BY: JANUARY 12, 2018 DATE COMPUTER FILE NAME V210 0 + COPY*WHT 2018 CARLOTn ARCHITGCT!, Pa ISLAND -0SPITAL CI-Y MULTI Additional refrigerant charge is needed depending on the size and length of extended piping. + Please refer the amount of pre-charge and the formula of calculation which is mentioned on DIAGRAM SYMBOL LEGEND CONT.No PAGE I YST _ C ' the data book. DISPLAY DESCRIPTION _ - ��� V . 1.25m416 MG) : 125mmt16 MG) or more. 0.15mm1(20 AWG) : between 0.5mm124 MG) and 0.75mmt(20 MG). ur POWER WIRE �, CONTROL WIRE System 1 REF. PIPE CU-1 3� —I—f ill 208-230V/60Fz FUSE PURY- 16-2 AWG(s) P72TLMU-A• CARLETTI ARCHITECTS P.S. architecture,planning,interior design uL2L3 TB7 116 EAST FIR STREET SUITE A PIPING LIST DIP swnce 3-7 OFF MOUNT A. 98273 SYMBOL BRANCH PIPE MODEL NAME 051 VERNON,� J1 Reducer SYMBOL UOUID PIPE GAS PIPE SUE Phone: 3601 424-0394 P1 1/4 1/2 TB3 i f Fox: 3601 424-5726 P3 5�8 3�4 16-2 AWG(S) (S) T -� PERMIT - BID SET IP3 I Our difference is engineered. BC-1 www.harrisgroup.com CMB-P106NU-G1 >16-2 AWG(S) TB2 052 PROVIDE 3/8"AND 3/4" INSULATED REFRIGERATION BALL Harris Grou 2core TB1 G VALVES WITH FLARE/SCHRADER FOR BC-CONTROLLER PORT. P PROJECT NO: 0070412.00 1 3 4 • • � /7 n. • Jt J1 ItJ1 J1 I JI I ISLAND HOSPITAL ____ If PRIMARY CARE CLINIC r EXPANSION AND IMPROVEMENTS I OB GYN CLINIC Li___1 208230 1 n f FUSE P1 P1 IP2 IPI 208 230V F - 208 230F� ,2Q8 230U� 2Q8-230U� 081-230V �- CONTACT: 1 + FUSE . + FUSE _FUSE % Intedock001 L1L2 G L1L2 G L1L2 G L1L2 G- TM, MIKE MCKENNA 001 Z 002 003 4- 004 - 005 Tay TB15 Gp1 T T Gp2 1 Gp3 TB5 TB15 Gp4 PEfY PEFY PEfY- TM4 Tay LGH- ' V. !PPEY 1NMA -E3 P12MM-E3 P24W -E3 P1814I4U-E3 F600RX5-E 'Vof : 16-2 AWG S " j1 `c ,"" �^16-2 tES) 2816-2 ruffs) 284-2 E(S) 2�1s-2 wrs(s) �' \sr�f tro-zar 41988 CR CR CR CR ' Aie1 ° t ZONE EAST , , ZONE U.S. , , LOtf NI , , ZONE WEST , I al. li , FC-1 , FC-2 FC-3 FC-4 SEE SHEET M2.0 FOR REFRIGERANT AND ' , ') CONDENSATE PIPING I � � L-i 18-201 \ =-� N I'KUJtL. I NUMIStK: rrrrrrr� 7rrrr�Tr�rTr7�T� \, T •O CT RS HALL 6"o CDL 8"o CDL _ __ �� I v. o %I i \ 8"0 CDL _ 114' 180 CFM E. T01 REVISIONS: AI 45 CFM ' I\�: , `,,180 CFM rill, i 8"p ddbL -_' rrilI i-R. •�44, - � EXAM-51 � IL 1�� Iao CD 83sCDon 02-20-18 PERMIT 1 BID SET A 8"g CDLi; kula 155 CFM 6"m CDL ��r ' vFD �__, yr,E +AM 4 135CFM L 0L EImCrf L. .\fy .tt N��*♦ — `i X�#M'1 CU / %��� 45 o �� 45 CFM �1- ♦♦� 1 - , , 2 1 �j110 ���.� , . , Li I El10 LOCATE ON 4FT SO. / �� . . I x ems, . 1 /�, CONCRETE PAD �4 �� 135aPill �. e -cs I. 24z12CGL 9� F sip T ,_ i j , M4.1 CFM '� 11gum P • !II 1 14"0I iL I��r.- % ri0. CGL 1 r ` "L;oilejoccDLNA /� I � I�145CFM I V�,' s. Al , - A 8Q0 CDM ,'�� 6"m CDL 24x12 C GAL f \• , IIIF., �Q.- \. 30 CF,, 95 CFM } 4 CFM �� �a) ��� ._ .. ._ sCDL �• ♦ ME WO 6aCDL / Ilia ....a..a �� :1 `1� / 40 CFM l d e"a II ��� 1 = lot s�� SHEET TITLE: • A c'-� �® -• �; � �C �\ 12"o OSA UP �' �zs cFMGL ® 101.111111111 :on ■ RooF HOODFLOOR PLAN REFRIGERANT PIPING / ,„,. AND WIRING COVER i I se i la j.® FOR ROOF PENITRATIONS / �__ " 24x12 CGL _ I/ 1 r �� I a CDL �\ all_ _ 1 © 00 CFM Vtill�� ■ riirimmiwai �� PLUMBING & HVAC r70CFM�-S _ 10"e -` 12 'weM�� _ � �� - FALL = M 2r� � ,I E A N 3 ridooll s°0 cDL �\ �/ ,� f ! / ' 109 r F 100 CFM,/ �, 102 ♦� II /1 / /��\ ■ tom. ���,- ; e CDL / ..1 8,0 ® �� 12 © �� __ 5E VESTI / i / 4 6"0 CDL m _ . -,1 0- ■0 ♦ i 3 / 45 CFM o rmxz,o-u3a" OQ - ' 5- �� 'Arm_01SN ROOF ABOVHOOD E i / z Q� I ® ■ x CGL 1®f■��� I / lit MINIMUM 25'-0"FROM EXHAUST ® ROOF DECK) jr • '� A CFM ���',^0CDLAND VENT OPENINGS d 6"o CDL �� v/ ♦ " 24x12 CGL , 4x12C ■ t:80 I '' 11,M71. /© / 75CFM �0.� I I V`/ 7� M � 1 50CFrvtIII 24x12CGL // 295 FM i r'L/ r �� f (} ( ...._....... ........ II :.. ( r .. _ 120 CFM k Ma.o ULTRA90U III ■ 1 z°© ri :. / �/ �iyh' 12X12DUCTP *VIDE / 08 _F� Q 5CF /-, it r2i, I Om .- �.r;• a r .� -. \` SUPPORT m B e CDL p D1 • •U R E � i PJC EXHAUST /r 370 CFM - v(�lc I ,_. I 104 \ PROJECT ARCHITECT: TERMINATION i u ._ 8"o CDL i �-� 1 - � 24x12 CDL 170� CFM �� �I/���"■f _R,.R, F 6 0 CDL L A m,is I I PJC �` / 107 �'- 80 CFM Min Kiser '� DRAWN DY: 3°VTR ` , , Maw 1001CFM GS /. . PJCi �.. ! a CHECKED D7 12"0 EXHAUST UP JANUARY 12, 2018 TO ROOF TERMINATION DATE PLAN PLh6' NORTH NORTH ROOF PLAN - HVAC FLOOR PLAN - HVAC 4t N, COMPUTER FILE NAME K>J 0 4 8 1 6' \J 0 2' 4' 8' 4.4 in.P.1.1.111....i 1.11.111..11.1111.111111 Nil 3 Ar 0 + SCALE: 1/8" = 1'-0" SCALE: 1/4" = 1'-0" COPYRIOM" MS CARLETTI ARCHITECTS, P.S. + Cr i 3/4" CONDENSATE TDRAIN CARLETTI ARCHITECTS P.S. architecture,planning,interior design GALVANIZED SHEETMETAL 116 EAST FIR STREET 7WEATHERHOOD 8" SQUARE SUITE A ri ELECTRICAL CONDUIT MOUNT VERNON, WA. 98273 REFRIGERATION PIPING ` VEFH on60 424-0 Fax: 360� 424-5726 @ )� FASTEN TO CURB AND CAULK —--- TREATED RAIL ROOF RIGID INSULATION PERMIT - BID SET ROOFING BY OTHERS Our difference q I is engineered. idosillsur r _ www.harrisgroup.com �..! 3/4" ll FLASHING COLLAR ROOF DECK Hams Group �_ ,...I 6 AND SEALANT, o FASTEN TO DECK "' PROJECT NO: 0070412.00 CABINET 1 PIPE PENETRATION THROUGH ROOF M4.0 SCALE:NTS ISLAND HOSPITAL FLOOR 2"WASTE PRIMARY CARE CLINIC l Q • 4 EXPANSION AND IMPROVEMENTS — OB GYN CLINIC 1 2THVAC CONDENSATE DRAIN TO SINK DETAIL M4.0 /SCALE. NTS CONTACT: ALUMINUM RAIN HOOD MIKE MCKENNA LAG SCREW TO JOIST(TYP) ;,,,& .V 7 TIE OFF TO ROOF BIRDSCREEN �, ' i. TIE OFF TO ROOF STRUCTURE SUPPLY DUCT 10. ,. STRUCTURE _ • ' d194 METAL BAND SUPPORT SUPPLY DUCT STRUCUTRAL JOISTS \ METAL BAND SUPPORT 6 STEEL UNISTRUT 3FT MIN 3/8"ALL THREAD r 1 SEAL DUCT OPENING 111111 FLEX DUCT WITH 2" *0111111 �� FASTEN TO CURBON ALL ����� �� �� 1SIDES FLEX DUCT WITH 2" , EXTERNAL INSULATION ``EXTERNAL INSULATION . �� MAX. LENGTH 6'-0" ‘ FACTORY ROOF CURB MAX. LENGTH 6'-0" ROOF SEAL ALL SURROUND WITH 18-201 SPIN-IN TAP FITTING NYLON DRAW BAND 1" MINIMUM HANGER PROPER METAL ROOF SEALANT 18-201 C. I NUMIStK: WITH AIR SCOOP & DAMPER STRAP (TYPICAL EVERY 10') LAY-IN SUPPLY AIR LAY-IN SUPPLY AIR NYLON DRAW BAND _ + DIFFUSER WITH —. DIFFUSER WITH n ROUND NECK & O.B.D. I fl ROUND NECK& O.B.D. ,=_ _1_ J� a =_L_L .J- / � REVISIONS: re T-BAR SUSPENDED T-BAR SUSPENDED TYPICAL DUCT J 02-20-18 PERMIT / BID SET CEILING CEILING OSA HOOD 4 SUPPLY DIFFUSER / DUCT WORK DETAIL 3 ROOF HOOD DETAIL M4.0 NTS M4.0 NTS SHEET TITLE: DETAILS 4 -- 7 SUPPLY DUCT RETURN AIR LAG SCREW(TYP) /DUCT ;` -- F' -- CEILING 3/4" UNISTRUT I O (11 ; STEEL UNISTRUT ; \ sin IINEOPRENE HANGER VIBRATIONI1V-- N ITLATION (TYP) III\ / L__________________,. Q D - /J 11 II f FBM FILTER BOX / OSA DUCT (4) 1/2"ALL THREAD RODS (4) 1/2"ALL THREAD RODS J/ W/MERV 7 FILTER HEAT EXCHANGER FAN COIL UNIT FAN COIL UNIT PJC PROJECT ARCHITECT: PJC DRAWN BY: • PJC CHECKED BY: JANUARY 12, 2018 CM FAN COIL DETAIL 6 FAN COIL INSTILLATION DETAIL 5 ENERGY RECOVERY VENTILATOR DETAIL DATE 4.0 j NTS M4.0 NTS M4.0 NTS COMPUTER FILE NAME V 411 1 0 COPYRIGHT 2013 CARL0ITI ARCHITECTS, PS. er ,, 1; ,i1111#;40 LIGHTING FIXTURE SCHEDULE SYMBOL LEGEND GENERAL NOTES CARLETTI ARCHITECTS PDS. TYPE DESCRIPTION LAMPS MOUNTING MANUFACTURER VA architecture,planning,interior design1. NOT ALL CONDUIT AND CONDUCTORS FOR BRANCH CIRCUITS HAVE BEEN SHOWN. IT IS THE RESPONS i:ILITY INDOOR LIGHTING & CONTROLS OF THE CON I RACTOR SHALL INSTALL ALL REQUIRED CONDUIT AND WIRE FOR A COMPLETE INSTALLATION. 116 EAST FIR STREET SUITE A 2x2 ARCHITECTURAL TROFFER WITH SHALLOW HOUSING, 3,400 LUMENS 2. PROVIDE UNSWITCHED CIRCUIT FOR ALL EXIT SIGNS AND EGRESS LIGHTING, UNLESS NOTED OTHERWISE. MET/kW% 42 2EN-LD2-34-UNV-1,840- 0 SURFACE OR PENDANT MOUNTED LIGHTING FIXTURE MOUNT VERNON, WA. 98273 F 1 CENTER LED BOARD WITH ACYRLIC LENS AND WHITE REFLECTOR, 4000K LED RECESSED 27 3. PROVIDE DEDICATED NEUTRAL FOR ALL BRANCH CIRCUITS. 0-10v DIMMING. (VERIFY COLOR) CD1 2X4 RECESSED MOUNTED LIGHTING FIXTURE?) Phone: (360) 424-0394 " " INDICATES CIRCUITING F : 1 )2x4 ARCHITECTURAL TROFFER WITH SHALLOW HOUSING, 4 METALUX#24EN-LD2-45-UNV L840- ,500 LUMENS 2o "a INDICATES SWITCHLEG 4. MINIMUM WIRE SIZES SHALL BE#12Cu ax 360 424-5726 , UNLESS NOTED OTHERWISE. - F2 CENTER LED BOARD WITH ACYRLIC LENS AND WHITE REFLECTOR, 4000K LED RECESSED 33 CDI 0-10V DIMMING, (VERIFY CO LOR) \ 2X2 RECESSED MOUNTED LIGHTING FIXTURE 5. THE LIGHTING FIXTURES SPECIFIED DO NOT SHOW ALL OF THE OPITIONS REQUIRED FOR INSTALLATION, THE CONTRACTOR SHALL PROVIDE ALL REQUIRED MOUNTING EQUIPMENT, FLANGE KITS, SUPPORTS, PENDANTS, -si A. 1000 LUMEN5 ETC. REQUIRED FOR THE SPECIFIC CEILING TYPE AT NO ADDITIONAL COST. CONTRACTOR SHALL COORDINATE crSer wacoe F3 COI A.REFLECTOR 0-10V DIMMING OPEN DOWNLIGHT WITH CLEAR SEMI-SPECULAR ALZAK 3000K in(VERIFY COLOR) MVOLT-EZIO UTHOMA a LDNI6-30/10-L06-AR-LSS- I 2 ' WALL MOUNTED LINEAR LIGHTING FIXTURE RECESSED 13 AND VERIFY CEILNG TYPES AND MOUNTING CONDITIONS WITH ARCHTECTURAL PLANS. , . gt,.. 0 RECESSED DOWNLIGHT FIXTURE 0. ' 6. COORDINATE EXACT DEVICE HEIGHTS AND LOCATIONS WITH FURNITURE LAYOUT AND ARCHITECTURAL I= otor ,C,1500 LUMENS ELEVATIONS PRIOR TO ROUGH-IN. 2 LED WALL BRACKET WITH INTEGRAL DRIVER HE W I LUAMS ti W MAUD-2-,ALUMINUM F4 3000K LED I SURFACE/WALL 40 Erni EXIT SIGN, - INDICATES DIRECTION OF ARROW 0, d"_add y HOUSING,ACRYLIC PRISMATIC LENS, i PH15/835-AF Art\ ;SY (VERIFY COLOR) 7. COORDINATE EQUIPMENT REQUIREMENTS (LOCATION, CONNECTION TYPE, CONTROLS, LOAD, VOLTAGE, ETC.) Jr i I 4 lit• '' •i' 2400 LUMENS ME COMBINATION EXIT SIGN/EMERGANCY LIGHTING UNIT WITH SUPPLIER PRIOR TO EQUIPMENT ORDERING AND ROUGH-IN. F5 14' LED UNDERCABI NET FIXTURE SPECIFICATION GRADE, 3000K LED SURFACE HE WILLIAMS tl LSE-4-124-830- 29 FRONT INTEGRAL DRIVER AF12125-UNV EMERGENCY LIGHTING UNIT 8. PROVIDE ALL CONDUIT AND 120V CONTROL WIRING FOR EQUIPMENT, tNCLUDING, BUT NOT LIMITED Ta. HVAC TRANSLUCENT , (VERIFY COLOR) EMERGENCY LIGHTING THERMOSTATS, ETC. 1800 LUMENS 16 SURFACE 3' LED UNDERCABI NET TU FIXRE,SPECIFICATION GRADE, HE WILLIAMS II LSE-34_18-830- 21 $a SINGLE POLE SWITCH - "a" INDICATES SWITCHLEG 9. VERIFY EQUIPMENT CONNECTION TYPE (RECEPTACLE OR HARD-WIRED CONNECTION)WITH EQUIPMENT ISLAND HOSPITAL 3000K LED TRANSLUCENT FRONT,INTEGRAL DRIVER (VERIFY COLOR) AF12125-UNV $3 THREE WAY SWITCH SUPPLIER, PRIOR TO ROUGH-IN,AND PROVIDE REQUIRED RECEPTACLE OR CONNECTON. PRIMARY CARE CLINIC 4424 LUMENS $D DIMMING LIGHTING CONTROL SYSTEM SWITCH (0-10y DC) 10. ALL DEVICES IN PATIENT CARE AREAS SHALL BE HOSPITAL GRADE AND GROUNDED TO CONFORM WITH EXPANSION AND IMPROVMENTS F7 4' UNEAR WRAPARUND LED FIXTURE SPECIFICATION GRADE 3000K LED SURFACE METALUX 44W5NLED-LD4-44SL-F-UNV- N.E.C. 517.13. OB GYN CLINIC ' 44 FROSTED ACRYLIC LING (VERIFY COLOR) L830-CD1-1.1 T COMBINATION WALL SWITCH/VACANCY SENSOR (SINGLE LOAD CONTROL) 11. ALL RECEPTACLES IN WAITING AREAS AND EXAM ROOMS SHALL BE TAMPER RESISTANT TYPE TO CONFORM . %-eit LED EXIT SIGN WITH INTEGRAL EMERGENCY BATTERY,WHITE T TO WAC 246-320-405 (9)(eXii) WALL SWITCH/OCCUPANCY SENSOR pc-f-4 L ° 1 OSPITAL CALCIUM BATTERY El THERMOPLASTIC HOUSING,STENCIL FACE GREEN LETTERS EW,LEAD LED UNIVERSAL LITHONIA L SERIES 216 (DUAL LOAD CONTROL) 12. CONTRACTOR SHALL VERIFY MEDICAL EQUIPMENT CONNECTION TYPE (RECEPTACLE OR HARD WIRED)WITH 0,1„,&..,a T COMBINATION WALL SWITCH/VACANCY SENSOR WITH SUPPLIER PRIOR TO ROUGH-IN, AND PROVIDE AS REQUIRED. CONTACT: • . LED EXIT SIGN AND EMERGENCY LIGHTING COMBINATION UNIT, I (0-10V) DIMMING (SINGLE LOAD CONTROL) MIKE MCKENNA . E2 WHITE THERMOPLASTIC HOUSING,STENCIL FACE GREEN LED 1UNIVERSAL LITHONIA ECR SERIES 3.8 13. CONTRACTOR TO LABEL ALL DEVICES AND LIGHTING WITH SERVING CIRCUIT NUMBER. LETTERS,LEAD CALCIUM BATTERY I yr WALL SWITCH/ OCCUPANCY SENSOR WITH MANUAL 'ON' EMERGENCY LIGHTING UNIT WITH WHITE THERMOPLASTIC 0 CM HOUSING,(2) ADJUSTABLE 1.5W LED HEADS PROVIDED,INTEGRAL SEALED WALL LITHONIA NELM2-LED-SD 13 CEILING MOUNTED - OCCUPANCY SENSOR WITH UNIT SEE DETAIL SHEET E2.1 AL MAINTENANCE FREE BATTERY AND SELF DIAGNOSTICS. FE PLUG-LOAD SENSOR CONTROLLER, SEE LIGHTING/PLUG-LOAD . V CONTROL DIAGRAM, SHEET E2.1 DEMOLITION NOTES , .. ? ,b, . 4 0 DIGITAL MANUAL WALL SWITCH DIMMER (0-10V) *!,:, .1 /1 ' ..k",, . . LIGHTING/PLUG-LOAD CONTROL DIAGRAM, SHEET E2.1 1. REMOVE ALL EXISTING ELECTRICAL EQUIPMENT, CONDUIT AND WIRE BACK TO SOURCE. OR NEAREST UPSTREAM ,, ,,' DEVICE NOT BEING REMOVED, ON SURFACES (WALLS, CEILINGS, FLOORS) BEING REMOVED AS PART OF THE Electrical Consultants, Inc. POWER CONTRACT. 19015 36th Avenue West, Suite E NEW Panel H PANEL SCHEDULE PROJECT: Island Hospital OB GYN Remodel I:a DUPLEX RECEPTACLE 2. REMOVE BACK TO SOURCE, EXISTING LOW VOLTAGE CABLING, CABLE TRAY, RACEWAY, MOUNTING EQUIPMENT, Lynnwood, Washington 98036 ETC., WHICH IS ASSOCIATED WITH FIBER/ TEL / COMM, TV, CALL SYSTEMS,AND FIRE ALARM DEVICES BEING Phone (425) 775-1799 FAX (425) 774-9870 120/208V, 3Ph,4W. 225A Bus M L.O. SURFACE WALL MOUNTED 20-Feb-18 OE DOUBLE DUPLEX RECEPTACLE . REMOVED. 18-201 Ckt Description / Load Load C.B. C.B. C.B. C.B. Load Load Description % Ckt 3. LEGALLY DISPOSE OF AND / OR RECYCLE MATERIAL BEING REMOVED AS REQUIRED BY STATE AND LOCAL Pt2C)JtC-1 NUMbtR: No. Location (VA) Type Amp Pole Phase Amp Pole (VA) Type Location No. C DUPLEX RECEPTACLE, MOUNTED ABOVE COUNTER AT JURISDICTIONAL AUTHORITIES +44" UNLESS NOTED OTHERWISE. 1 LTG-CLINIC 1,551 L 20 1 A 40 3 2,880 H CU-1 2 3 REC -DOCTORS 114 900 R 20 1 B _ 2880 H - 4 4. MAINTAIN, REPAIR, OR REPLACE EXISTING SYSTEMS NOT BEING INTERRUPTEDAFFECTED , BUT ARE BY REVISIONS: - _ ,5 REC -EXAM 1 - 102 900 R 20 1 C 2880 H - 6 la CONTROLLED RECEPTACLE, SEE LIGHTING/PLUG-LOAD DEMOLITION WORK. PROVIDE TEMPORARY POWER (GENERATOR) IN ORDER TO MAINTAIN FUNCTIONALITY OF - - , 7 REC -EXAM 2 103 720 R 20 1 A 20 3 1 667 H DH-1 8 NE CONTROL DIAGRAM, ET E2.1 EXISTING SYSTEM IF REQUIRED. 02-20-18 PERMIT / BID SET - , 9 REC -EXAM 2 - 103 720 R 20 1 B - - 1,667 H - 10 11 REC EXAM 6 104 540 R 20 1 _ C - - 1 667 H - 12 0 DUPLEX RECEPTACLE, KI TYPE 5. COORDINATE ANY TEMPORARY INTERRUPTIONS IN POWER WITH OWNER AND ARCHITECT. SUBMIT SCHEDULE TO - - 13 REC -EXAM 6 - 104, CLEAN - 105 900 R _ 20 1 A 20 2 696 H FC-1 THRU 4 14 OWNER FOR APPROVAL, MINIMUM ONE WEEK PRIOR TO PROPOSED POWER NTERRUPTION. rr DUPLEX RECEPTACLE, GFCI TYPE, ABOVE COUNTER 15 REC -MA/RN - 113 720 R 20 1 B 696 H - 16 17 REC -DIRTY - 106, RR- 107 900 R 20 1 C 20 - 428 H HVR-1 & BC-1 18 mi. DUPLEX RECEPTACLE, RECESSED FLOOR POKE-THRU DEVICE, 6. FOR THE REPLACEMENT OF ANY EXISTING DEVICES WITH NEW -THE CONTRACTOR SHALL MODIFY, PATCH, AND - - - imi REPAIR THE EXISTING SURFACE TO ACCOMMODATE NEW DEVICE OR LIGHTING FIXTURE. PROVIDE NEW 19 REC -ULTRASOUND - 108 7201 R 20 1 A - 428 H - 20 air.. 21 REC ULTRASOUND MACHINE 1,200 G 20 1 B 20 1 750 H EH-1 22 PROVIDE 3/4" CONDUIT UNDERFLOOR BACK TO PANEL. MOUNTING EQUIPMENT AND SUPPORT, AS REQUIRED. EXTEND CONDUIT AND WIRE TO NEW DEVICE AS REQUIRED. - 23 REC -ULTRASOUND - 108, CEILING 180 R 20 1 C 20 1 500 H EH-2 24 C)25 REC -EXAM 3 -109 9 R 20 1 A 20 1 SPARE 26 SPECIAL PURPOSE RECEPTACLE, AS NOTED 7. PATCH, REPAIR, AND PAif lls EXISTING SURFACES THAT ARE AFFECTED BY REMOVAL OF EQUIPMENT, TO 00 ORIGINAL CONDITION. FIRE SEAL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES. COORDINATE PAINT COLOR 27 REC -EXAM 4 - 110 .C,0 R 20 1 - B 20 1 SPARE 28 29 REC -EXAM 5 -112 900 R 20 1 C 20 1 SPARE CD JUNCTION BOX W T11-1 OWNER, REPAIR IS SUBJECT TO APPROVAL BY OWNER AND ARCHITECT, 30 31 CALL SYSTEM POWER SUPPLY 200 _G 20 1 A 20 1 SPARE 32 33 REC -MA/RN - 113, COUNTER 360 R 20 1 B 20 1 SPARE 34 ---___,..- CIRCUIT HOMERUN - MIN 3/4"C-2#12 PLUS #12GND 13. WORK SHALL BE DONE TO REDUCE DOWNTIME DURING WORKING HOURS. COORDINATE ESTIMATED SCHEDULE 35 REC -EXTERIOR 180 R 20 1 C , SPACE 36 UNLESS NOTED OTHERWISE. OF SERVICE INTERRUPTION WITH OWNER/ARCHITECT PRIOR TO BID. 37 SPARE 20 1 A SPACE 38 . CONDUIT CONCEALED IN WALLS OR CEILING. 39 SPARE 20 I B , SPACE 40 41 SPARE 20 1 C SPACE 42 - - - CONDUIT UNDER FLOOR OR UNDERGROUND. , . Total Connected Load: Ph A 10,662 VA 89 A 0 CONDUIT UP SHEET TITLE: Total Connected Load: Ph B 10,793 VA 90 A Total Connected Load: Ph C 9.075 VA 76 A PANELBOARD ELECTRICAL COVER SHEET Total Connected Load: 30.5 KVA Total Demand Load: 30 7 KVA 84.8 AMPS 85.3 AMPS LOW VOLTAGE / COMMUNICATIONS Connected Subfed Total Demand Demand Loads Loads (S) Loads Factor Load G General (Non-Continuous) 1,400 0 1,400 100% 1,400 V WALL MOUNTED DATA OUTLET - PROVIDE BACKBOX AND L Lighting 1,551 0 1,551 125% 1,939 STUB 3/4"C. UP TO ACCESSIBLE CEILING SPACE R Receptacles -to1OKVA 10,440 0 10,000 100% 10,000 over 10 KVA 0 440 50% 220 Iyi DATA OUTLET - FLOOR MOUNTED POKE-THUR DEVICE, K Kitchen 0 0 0 100% 0 PROVIDE CONDUIT UNDERFLOOR TO IDF. H Heating 17,139 0 17,139 100% 17,139 M Motors 0 0 , 0 100% 0 LM Largest Motor 0 0 0 125% 0 I-• NURSE CALL DEVICE - EMERGENCY PULL CORD (+54" AFF) VVH VVeter Heater 0 0 0 125% 0 C Continuous General Load 0 0 0 125% 0 0 NURSE CALL DUAL DOME LIGHT (CEILING MOUNTED) 30,530 VA 0 VA i 30,530 VA 30,698 VA SHEET INDEX CALL OUTS PLC • PROJECT ARCHITECT: > DETAIL NOTE E0.0 ELECTRICAL COVER SHEET, PANEL SCHED. RAD c,..., r,.. -ii• B : F2 LIGHTING FIXTURE TYPE. SEE FIXTURE SCHEDULE. E1.0 OVERALL ELECTRICAL PLAN DRAWN Y BAA i..: EF-21 EQUIPMENT CALLOUT - SEE EQUIPMENT SCHEDULES E2.0 DEMOLITION & PROPOSED LIGHTING PLAN CHECKED BY: E2.1 DEMOLITION & PROPOSED POWER PLAN JANUARY 12, 2018 9C---) (N) NEW E3.1 PARTIAL RISER DIAGRAM DATE a; <0. (E) EXISTING -..a, Eir c COMPUTER FILE NAME c...t- 0 . 0 _ - -E COPYRIGHT 2018 CARLETTI ARCHITECTS. P.S. 1 . . I I, J E I1 - ,II tI 1II 1, + 1 i 2 1 CARLETTI ARCHITECTS POS. 1----1‘ r- -..,. architecture,planning,interior design :t ' \-----. F 1.} . 1 ' 116 EAST FIR STREET SUITE A MOUNT VERNON. WA. 98273 , --, - I Phone: (3601 424-0394 ±-,- Fox: (360) 424-5726 1 1 1 I 7-11 II: I 1 II A EEL_ i I 4 „ • ILJ __I ___It-- I-4.- 4 0 • 11/2 , it;ft 7974.: i\ea 1111 . '4 Z ,,,••••• XI 1 . 8 •,,„„ , _____F------1-----87-44--E-n1;4481T--nrszT----- '.7ii ._....... i ....dir •4-, , / 4 y et Atlie, 1111 !I --..--- 11 - ' I r I II I 1 1 1 . -- _ . ---_.........----- .: NI- ISLAND HOSPITAL i it • 4, :,---- ' 1 . PRIMARY CARE CLINIC '11 0 f ', ' I I i -- . 1 11 1, ; -El EXPANSION AND IMPROVMENTS .........__...... _ ____ _ ___ , ----------,-- --r- ----1 -------7-..:7= — — T7,--= .-.:1-11-.=2:= "==-188:1--==1-72171.1--11111_-------i 05 GIN CLINIC 1 ( . ..1. • . , , . II , f, 1 - I ,,4Tig;,-- 1 , IT, a I I , 1 . ourpc worm wAujirP) ----•,I, , 0 z. - 1 I; „,/i r.i.J . . I . I I 1 1 ,Ti. I ;I I : i ' I ; . - 1 ' . _ I-,;;;\ ; I I 1 , IC 1 1 '04 ; I , , , •, , I .1 i LI • ; _.., • , ;1 1 i LL-----I 1 • 1 0 ti ' , I I I ALANDHOSPIThL I 1 ' E ..F-1404.3.4FT(FtP; ,-...-ij I , / • ' '\\\. /7 ti ,,,j_....,,,,i, '--• ! ,. , , . , . 4.6',.'C.M1 ( . 1. 1 ...........- ._. \I CONTACT:i i 1 , 1 I 2e MIR I ij. LI ( Vr :1... ....=I ...; i MIKE MCKENNA I -- ------ - . ; I Di I C-,.... >1 EL) I Ii'17 1.1c,; -— • ' -it ;i 7 -.E --, , - 14, if I . . , ;II II-Th; , ri-, i ______ ea_ , Cif r I i I i & & , . I L -/ -------- 2 k ..?i \\-----, ,--/ .. - - ---- n I - ' , . 1 1 11 1 1 1 :Hit • 1 Lt).1. 1 I' 1 q I ; [ . .' a =110 . .. 7--- 1[ 0 I rir- . _r-17.- ' r I i s A i fim 1 T______ „ 1 1 Electrical Consultants, Inca ia i 1\--71 _____ - . 1 iiia f I „...... --- I I 8 19015 36th Avenue West, Suite E . im 1 - rrcr' i Lynnwood, WaShington 98036 ‘, . I% 1 - 1 z....\,„ Phone (425) 775-1.799 FAX(425) 774-9870 fr)7 , - 1 r..,..., ,...?:, J. r,l .,.. , 1 J . . , ...._. . , .._.......,g!.. i _ „,,,, 1,,.,..., t7-I 18-201 N••- K -- ;;; '\, 1-23' 1)1 A . 11--'N\ . 1 _---- hakUJtC; I NUMbtN: MAIN EXIT EXISTING „Fr 4 II' ' I W/ PANIC HARDWARE ____--- II 8'1_ ty IN1------------- i.I _ ___ ......._, . 1 . I 1 rr--/ ....____...r . REVISIONS: i I ' 1 • i r . 1 .i , inn 111111111111 1 .1 L 1- . ' '---- . 1 ---- -------- r--- -------9\_dr• - --k .... 02-20-18 PERMIT / I3ID SET I . , ' ci , I , , i 1 ..11 -It ; 11 1, -- -- 1 II 1,..._ =I . F. ...L...... 71====r ' I --* I . . COA.E1 k , . , ' . 1 MN=I-- SM.I I I I I j , . iT i ''II -L. 1 , . II I ;1 . ( zi rcrd , . 4111 : . 6r41 : ; ' ' E ----- I ..'. 1 ir I .. 1, zi • : I _ __. . I 1 (--- 1 _ 11 •. _ _ . . 1 1 .1 1 EMI D I GFIM I 9 I It i ' : : „------- „ _ 2_____;11 • 44 • te''' n'm I 88 t 0 I . I I i I _ , ,8 I I 8- 12Ow i . , I 4/ ''' . ., , ""E: I ----- ...!<rnanry, i '! . El• i EL. , ,f sztmt.a. , I FIDALGO L..... 8 , 1 • SHEET TITLE: I( I • ( I 1 . IN! 71 , :. 11 r MAIN EXIT EXISTING \ W/ PANIC HARDWARE -. MEDICAL _ 1 , , OVERALL FLOOR PLAN r ASSOCIATES , . & BREAKWAY PANEL _, -e> frh I . 1 -1:71 -2884, . ..... . i i.! ----. K.-.OAFANI. .- -, - . ...,.....al 1 i I ( j T.:. REFER TO SHEETS 888i , i E2.1 AND E2.2 FOR , I -1 1 • ,.. WORK IN THIS AREA i I ! , L. 1. 1 I • ...._ . 1 I ---L • ,L-1 ,-, CI , ; . _/(.,, _, 8,- I ; -e, . ,..._ 0--- I PLC , I ! i r 1 I I KIEL W/ PA. IC HARDWARE 4-84 & 5R- KWAY PANEL I •4--- --j t , 1, I I I ,-, 1 I 1 PROJECT ARCHITECT: ..„_____ , L . I 1 RAD I DRAWN BY: 15 AA 1.t. CHECKED BY: G JANUARY 12. 2018 , . DATE .;,• n -.; .,-.• .;,,,...2 COMPUTER FILE NAME -, ,E-.... C.,`E; OVEALL 7.: XISTI \ G FLOOR PLA \ , ...?.. . 0 ...., t,..). • _ + COPYRIGHT 201S CARLETTI ARCHITECTS. P.S. + --, _, , ---.— LINE VOLTAGE IN A49/ Ai 9 = CLASS 2 (0-10y) CONTROL WIRING # , - VIOLET- -1 r- GRAY 4 ft r- -i . ri n, --,-1 r - 1 44,4,,,Ar r ——- :: : ni i 1 I r- DIGITAL , I 1 , Iii 1 MANUAL SWITCHES , 1 ,.. LINE VOLTAGE GENERAL NOTES: CARLETTI ARCHITECTS P.S. (0-1 Oy DIMMING) IL_ _ NEUTRAL architecture,planning,interior design SEE SWITCH DETAIL L_ ____ _ ROOM LIGHTING RED I L 1. ALL EXISTING DEVICES IN TENANT IMPROVEMENT AREA SHALL BE L _ (O-1OV)CONTROLLER NEUTRAL _J INDICATES SWITCH-LEG = = = REMOVED. REFER TO DEMOLITION NOTES ON SHEET E-0.0. 116 EAST FIR STREET YELLOW PRESS AND HOLD TO DIM ...-DIM UP A A DIM UP DIM DOM Ns CAT5E CABLE 1--- --- -- DIMMING -NEUTRAL SINGLE TAP "ON" _,_--,-00 CoN) OFF) 2. CONTRACTOR SHALL COORDINATE ALL POWER INTERRUPTIONS WITH SUITE A NE BLUE 0 - - - --1--I - - - I DIM DOM o o B B HOSPITAL REPRESENTATIVE. PROVIDE SHUT-DOWN SCHEDULE MOUNT VERNON, WA. 98273 MINIMUM TWO-WEEKS PRIOR TO ANY WORK BEING PREFORMED. D (13FD 000 (cal Phone: (3601 424-0394 RC , LIGHTING Fox: (360) 424-5726 CAT5E CABLE LOADS -.N., (RJ45 CONNECTORS) --.— LINE VOLTAGE IN El SPLIT WIRED" D1 02 II&svANC80 Jim_ I .- I RECEPTACLE '10ame - - `Aftw LIGHTING CONTROLS 'SWITCH DETAIL' BOX UNSWITCHED HOT I JUNCTION I of ,...„ OCCUPANCY , ,--- NOT TO SCALE 41-20,Oril SENSOR PLUG-LOAD SWITCHED HOT 0 --0 CONTROLLER N 11 •--PERMANENTLY MARKED WITH " (I) " TO INDICATE lb CONTROLLED RECEPTACLE A LV CONNECTION TO SENSOR IS - REQUIRED FOR INSTANCES WHERE A LIGHTING ROOM CONTROLLER IS NOT PRESENT CI ISLAND HOSPITAL PRIMARY CARE CLINIC LIGHTING1PLUG-LOAD CONTROL DIAGRAM EXPANSION AND IMPROVMENTS OB GYN CLINIC NOT TO SCALE • -Nom., / \ . \ / I I i 17. . ISLAND HOSPITML .• ..................._......_....•. •. CONTACT: MIKE MCKENNA I - , r it: I L 1 -I 14. . . .. .0 imil..1. ..r... im .1 :_ ___ __ __ __ __ __ _, t J 11 F5 b, t 1 F5 b • 1 r, ,, 1 _ ,, , r _„,,,______ ________ A 11 P 1 t/ il II _ ,......,...._._.... _ _____ , cci-- -‘1 1 N Fl 1 77-77 77 77•••=7.1:1=7..!, r!l5t.:,,:::1 ASI • . \II, -...-..-m- ..• ".--,-'2'.'":7,-I.1_w. , „ , , ' --- . , . , a , . , immbiF84.1(1.1-1 . IT -F 6.7 1"s ;,,:i l•,1 1.! v I 1 :k•'s N„_,....,L Lad\N\ L_ __ ___I I .; ,, F. 0 1 \ Fl 1 CN Fl 0 0 E2 EXIT al GI 1 • ?, • 7)0CTORS Fe Electrical Consultants, Inc. 1 ; I ! ::,, ,,,g •••I 0 7... ..!ir 1 . . / ,," .-1 1 .• ::, . i I EXAM-5 Fl ': HALL :4 !, > 1 114 (8 " 19015 36th Avenue West, Suite E , --- ''' ' - --1 :1 h, ce) ' 0 i Lynnwood, Washington 98036 , -1-- --'' " ri , FT, ,, *--- r 1 . I ' ' 1 .e c'''' 1 1 1„.. - i b , 1 0 i 1 6\ Fi 1 Lil' 1 at 1 1,:', Phone (425) 775-1799 FAX (425) 774-9870 i!, 1 I I I „ 1 nj 410111114 1 F5 ; ' 1,1 i( ) '....- \, ii i _ J „.. , ;: , c, I ' 1 : a ' a I , I 101 „ -; A 0 t 18-201 , 7,..-----11 __. .=_- ---1i 'r , ., S - ,It at- *S. /1 . .... i . . . . . , , „.„-.... • a ("NW t G I NUM(OtN: - F2 F2 "1-7(\ \\Fi 1 I -„,.. 10c I Al 41766- F2 F2 . , ![/ , / \ I I 6, .9 ., ) 1 - / mm m pm mlmF bm mi ' ktX A v-1 1 il 1 ,c HI '7.-- iii ,,1 J4 b i i 1 1. 102 ;'.. REVISIONS: , ID21,b ' I \\\, t: \ '44 I -,\ I )! ,/ 1 . i i F5 . 0 ; I 44 k 4- 44 .. . , I ,..t'::.1'/i''.0'' -, ri •,..", --- A a a:icil 02-20-18 PERMIT / BID SET ---, 1 a Li -,1 44, MA'S/RN'S (14:4 K 1 1 i a, . r / „.,' /I ; I ... / f I I E` •AM-4 / ,Am ! L I .... /I __ 7 _./7/ i Li. ‘ ,/ —........---, „ 11 0 1 1 1 . I 1 d r:4-1 7-rii t-- _J 1:i : 1c,;::: ,. . : _ .. b.,\a b\a 11 , EXAM-2 / 41 bl___II L. , ----- --- __._.,„,,...,_. 1 Fl , 1 Fl ., 1 \Fl . 1 Fl 1 1 r 1_103 ' __,....... 1 , • / El ' 2 d;* s;', , I Li.ria ss \___ .„- I akiir mr :: / REFER TO DEMOLITION NOTES ON 1 r4 7 I i :40 „ /1 lib ' a t >IT 1 1 ;! f SHEET E0.0 FOR WORK IN THIS AREA. i F-- — — — -- — — — — —I I I ' I ° I F2 N.-------'1 :: I j .._ ELL i i / F6 1 1 ;12 i _ , / ',./ el • 0 a,b lEI a a a a Fl , r 0 J:! a ta E;, ,/ -' F' b 6 1 1111 F2 F2 V. ,-.,/ i EV AM-a tir EM 1 Fl 1 II Fl 1 \Fl I asti...:II:: 117 I 4 i I-ALL .... 1 ....) liH-1 il 7 F2 E A 1 --)\--1 r,----51, b F 1 sii . . .1 i,--er:i t \.... 1 , 1 tr H 1 _ 00 ,... - ...,. .. , - -- -- — - /,!-- , - - --- --- Iii --': -• -::.!!, IT • , D2 a,bi. SHEET TITLE: L,.----------- i 11 \ :4 ' la,b i'l I i 4,b VESTIBULE ! ' WI l I II , li \ II I id Ai— li \ / " ' '.0 • .1 / . i, DEMOLITION LIGHTING PLAN . 11 I Sib Irpi re b i 1: i . i 1 • 11 ,„, 1, \IFY---- - Fl -\------cl ° , Fl a -.,... II I I \ nu PROPOSED LIGHTING PLAN II I 1 1 ELECI fl H...-1 46,!..:seni as,;;BiliMiteiptPdWat 1 0 CI .., 2 PANEL. ‘'.„,....,..L..,>, I -*wij" li F7 I :I IMT0-5-1 EXAM-6 ULTRASOUND L . 1 , ' , -- ar 0 „ IT ,;i:i T I 10 4 Fe ' I 1 0 8 I b i 2 1 ,i:: qi 1/411 Vii , .,„ 1 FS f. 1 lb itiy. lit 4ii - — \ ix h-----(11:N-......„.....„ N- . iri .. R.R. - I la I r F2 ,..,, .,......4._i - if D I R TY . 7 1 6, 1 F' 5 • Fe ,, ' --.. • ____ 107 i ' `t- 7------1 . I Br I - FL— N\ F Tr r- —1 r , , ,„„ - Lioe ! 1C--3 TEL. . A •0 ' 41 , '41 .„ • 1 ...k t--------.....-........-- -.....---•......-- ------------------. 1-- i 1 I I L_ _J 1 _,_14.J 'IP :L.„L_L-L .,,' F4 :-4 - - , In' — 7 7--- -777 77777 /77772 7/77777777777777777 7777777 7 7777,7•777•7'7'r7-7-7-777777,./ s,•; PLC.,. PROJECT ARCHITECT: L;- RAD DRAWN BY: BAA CHECKED BY: 0DEVO / EXISTI \ G FLA \ joe "ik OPOPOSED tr. L00 PLA \ r\ JANUARY 12, 2018 fr DATE 1/41.11-0. 4 1/4'4-0' 4 PE' COMPUTER FILE NAME _ . + COPYRIGHT 2015 CARLETTI ARCHITMCTS. P.S. :,./5.. r F / 4 EQUIPMENT FEEDER SCHEDULE GENERAL NOTES: 3, MECHANICAL / ELECTRICAL COORD. i1,r EQUIPMENT VOLT/PHASE HP/ KW FLA MCA I STARTER/DISC FEEDER 1. ALL EXISTING DEVICES IN TENANT IMPROVEMENT AREA SHALL BE WATTS BY E.C. (Cu) UNLESS OTHERWISE INDICATED,ALL MECHANICAL EQUIPMENT MOTORS AND CONTROLS SHALL REMOVED. REFER TO DEMOLITION NOTES ON SHEET E-0.0. BE FURNISHED, SET IN PLACE AND WIRED IN ACCORDANCE WITH DIVISION 15 OR 16, SEE BELOW CA R I.E TT I A RC Gi I T€C T S PaS a C13-1 208/3 24 DISC-3Ct/3Q 314"C,4#1t7, 1#10GND 2. CONTRACTOR SHALL COORDINATE ALL POWER INTERRUPTIONS WITH architecture,planning,interior design HOSPITAL REPRESENTATIVE. PROVIDE SHUT-DOWN SCHEDULE FC-1 208/1 - - - 1.20 MANUAL 3/4"C,3#12, 1#12GND LINE VOLTAGE-HVAC CONTROLS AND INTERLOCKS& MINIMUM TWO-WEEKS PRIOR TO ANY WORK BEING PREFORMED. 116 EAST FIR STREET 4� FC,2 208/1 1.20 MANUAL 314"C,3#12, 1#12GND CONDUIT, CONDUCTORS AND CONNECTIONS BY ELECTRICAL CONTRACTOR. SUITE A / -Errs 20811 - _ 2.73 MANUAL 3/4"C,3#12, 1#12GND MOUNT VERNON. WA. 98273 FC-4 20811 - - - 1.56 MANUAL 3/4"C,3#12, 1#12GND -_ LOW VOLTAGE-HVAC CONTROLS AND INTERLOCKS: DETAIL NOTES: CONDUIT BY ELECTRICAL CONTRACTOR, CONDUCTORS AND CONNECTIONS BY MECHANICAL CONTRACTOR Phone: �3601 424-0394 HRV-1 208/1 - - 3.6 MANUAL 314"C 3#12 1#12GND EXISTING PANEL H SHALL BE REMOVED AND REPLACED WITH NEW. Fax: 360) 424-5726 INTERCEPT AND EXTEND EXISTING 125A FEEDER TO NEW PANEL H BC-1 20811 0.52 MANUAL 3/4"C33#12, 1#12GND LOCATION WITH NEC APPROVED SPLICE KIT, AND ASSOCIATED J-BOX AS REQUIRED. CONTRACTOR SHALL PROVIDE ACCESS HATCH AT EH-1 120/1 750W - - - CONNECTION 3/4"C,2#12, 1#12GND ' LOCATION OF J-BOX. ,,/ A. iia EH-2 120/1 500W - - - CONNECTION 3/4"C,2#12, 1#12GND © EXISTING FIBER/TEL/COMM CABLING TO BE RELOCATED BY OWNER. v w e° OH-1 20813 - 3.5 - - DISC-30/20 314't,4#12, 1#12GND 0 ©► REFER TO LIGHTING/PLUGLOAD CONTROL DIAGRAM ON SHEET E2.1. al x „FT, Notes: (MC MECHAN ICAL CONTRACTOR) +' % 1. MOTOR STARTER iDISCONNECTSVVITCHBYE.0. (EC ELECTRICAL CONTRACTOR) PROVIDE MANUAL MOTOR STARTER WITH THERMAL OVERLOAD SIZED ' '' / le MECHANICAL CONTRACTOR. CONNECTION DIRECT CONNECTION TO MATCH MOTORS STARTING CURRENT OR MCA. COORDINATE WITH ° MANUAL-120Vt208V MANUAL MOTOR STARTER WITH THERMAL OVERLOAD COMBO COMBINATION FUSED DISCONNECT I MAGNETIC MOTOR STARTER © CONTRACTOR SHALL MOUNT DISCONNECT SWITCH AT NEAREST DISC BUSED DISCONNECTSWTFOH _ AVAILABLE EXTERIOR WALL SPACE. PROVIDE FREE STANDING 2, INTERLOCK WIRING BY E.C. AS DIRECTED BY M.G. 3, DUCT SMOKE DETECTORS BY KC.. INSTALLATION,CONTROL WIRING,CONNECTIONS UNI-STRUT FOR MOUNTING IF WALL SPACE IS NOT AVAILABLE. ISLAND HOSPITAL TOFDOO C > CALL SYSTEM SYSTEMS TECHNOLOGY VISIONLINK II WIRELESS PRIMARY CARE CLINIC 4, OUTDOOR EOUIP[t NTSHALLfENEMASR NURSE CALL SYSTEM, OR APPROVED EQUAL, BY CONTRACTOR. 5. INDOOR UNIT FED FROM OUTDOOR UNIT. EXPANSION AND IMPROVMENTS 6. REFER TO DRAWrIGS FOR EQUIPMENT LOCATIONS AND QUANTITY. 00- PROVIDE POKE-THRU FLOORBOXE(S) AND RUN CONDUIT IN OB GYN CLINIC ACCESSIBLE CEILING BELOW. COORDINATE EXACT FLOORBOX I • AND CASEWORK ER LEEGRANDNS EVOLUITIONNSERIES (8" DIA) OR APPROVEDREQUAL _1 "" ..., := :-I POWER CONDUIT SHALL BE ROUTED BACK TO PANEL H. DHOS3 �, A DATA CONDUIT SHALL BE ROUTED BACK TO NEW IDE LOCATION. ROUTE DATA CONDUIT TO NEAREST WALL AND UP TO ACCESSIBLE CONTACT: CEILING. COORDINATE IDE LOCATION WITH OWNER PRIOR TO I _ ROUGH-IN. MIKE MCKENNA ___________„......_______._________"\._____________________ _ II z5 2� I I--- II f `` ` I II T_ J,I 114. sag r _k. -1 r I H I I r �4 , z / r»r , .. f i r ,r >, 7�_.,. DOCTORS I Imo_ �! I . A . BC-1 -. f I 114ii' ui lei?, CALL SYSTEM C { � I H 35 M� ' PL 5 t ' STOR. P POWER SUPPLY 29 „ , HALL f _ j Cu-1 11a ,� _ 3 Electrical Consultants, Inc. =t_ L, / ,2--"'" ' _ H 2 4 6 1Ot 1 '.- -.-.-._..__.._ , ..E61 e----7 29 EXAM-5 j - ► ; 19015 36th Avenue West, Suite E 1 I 112 �- ► Lynnwood, Washington 98036 I ! ! }� I I %=` I -i�� H-31 Ir , H 5 '— 5 EXAM-1 5 Phone (425) 775-1799 FAX (425) 774-9870 . r I/` I ! CALL SYSTEM �( 18-201 z - - � �. 27 27_ + 1 I 3 3 H 3 �/ MASTER PANEL ` PNUJC(: I NUMBCR: V1 7f \ 11 1!— _1j �� ; I EXAM-4 29 i ; , 5 I N- 1 L- , E� i 3 - -_ I 1 1 ;I ; � iH 3 y , REVISIONS: d , L_1 f - �� {� 7 11 j j $ M 02 20 18 PERMIT / BID SET (T , - - - - I I - 27 H 29 ,- 1�1 �, L _ _ T`= � } Cy V 1 --- - ��' I I (ISM MA'S/RN'S FC 4 ''e n, I14__:I C 1 ' L - - SR--- I 27 -- H 14,16-3 113 H-14,16 I 7 �I 0je :-_ III7 1 __ __ _ _ M 3_2 3 4"C �. E X �' 25 H 27 ( : ::� �� 10HVR i r, / REFER TO DEMOLITION NOTES ON (- - 7 I I / " „_, ,_� uo1 u:n SHEET E0.0 FOR WORK IN THIS ARE . I- -{ ) �rCy, ,_.� H 9 LL I -i g _ .-.. --- 9 H 18,20 ►f',3 % / EXAM-3 - 25 H-25 H 15 DH-1 9 M 7 �p t 1Cg ( FC-2 H-8,10,12 t`' + ' I FALL M H 7 2z j 25 4 ' H 14,16 102 I! ! 25 = G ( $ pi 9 �17 , 41 r I F II I i II \ ;i4MOP s NEW) + 111 Y SHEET TITLE: _ g V' ! I I11 �Er �StiI \ I II l C I rr II �� 17 . - 13 I ID ••' PANEL H ( I ii1 ( ) \� �/ , SCALE H-1 2 1DEMOLITION POWER PLAN EXST \ u II \ - H- H ■ F r MOP' PANEL H 1 I ( III \ 0 H 17 i17 , (, 11 PANEL L 1 I III ULTRASOUND ������ -e _ v I ' -.__ , i ) PROPOSED POWER PLAN EH 1 - -- - - ___ J -� ' .1 108 H-23 - .— H 22 `"Q ) CLEAN - - I�'19 H-19 �1 ( ___. 1 105 ---- 1 EXAM-6 1 ( <CLG E .2 DIRTY 13 104 ti 106 L I � ; b --- - R.R. r 1 ■ _1 I 1� • ' "! NI 13 x ' \ Er i`1 — — — — -� _ 107 1 ; ._..____ .....__..._ ■- 1 _ 1 ��- TEL --1.. I r - - EI ��. - - (� _. ©� �,; ` 19 191(� iM1 a ) 17 ( 1 ` ( - - .. .---. .....__ E),: - a � II II 13 13 I i r u!— T _ r'j T 7 ;T 7 %;..../ /, iii `T 7` //, :/ ! //////, /;/ '//// / /////, / //////'/ l??T'/- T 1 �7 �0 --5 ___-..__ _.-./- _/_ .,__ T_. 2,/1_%I' 1 ./ 1 ._'_` _. .2_._u11 1_:_/_;C21/'1__:: -Z2.2z2Z__/ 72_,,_1/L:� 2_:/.-: 'T__7 T1!11_..Z i_1...:/ _--. ''_..... PLC PROJECT ARCHITECT: IT RAD DRAWN BY: BAA CHECKED BY: , XVO / XISTI \ G PLA \ S , ° RQ ° OS = J = � oo � ° LA \ 5 JANUARY 12. 2018 zt 1/4'=1' 0' DATE :7,,c. : '. COMPUTER FILE NAME COPYRIGHT 2015 CARLETTI ARCHITECTS. P.S. -4,a + . . ROOF CARLETTI ARCHITECTS POS a architecture,planning,interior design 116 EAST FIR STREET SUITE A MOUNT VERNON, WA. 98273 Phone: (360) 424-0394 Fax: 360 424-5726 $ (N) 2"C-4#2/0 AL 1 - PANEL 0 A. 41, . i 10' H 1 . fleet WASitt,:c'eip /0:411/firt"frat.1 1 i 11111,1<° 77 1 , (NEW) , < c) (E) 2"C-4#2/0 AL UPPER FLR. 1 r ISLAND HOSPITAL PRIMARY CARE CLINIC EXPANSION AND IMPROVMENTS OB GIN CLINIC , MAIN DIST SWITCHBOARD ' PANE PAV_ -. . - , I \ CONTACT: (EXST) .I MIKE MCKENNA C/T LOWER FLR. ! , 2,./ ... — . . — .. . .... . . ...... ,,A,, Ag • PANEL IS --1.---: DIAGAV Electrical Consultants, Inc. 19015 36th Avenue West, Suite E NO SCALE Lynnwood, Washington 98036 s Phone (425) 775-1799 FAX (425) 774-9870 18-201 'S HKOJtC-1 NUMbtR: REVISIONS: I . (E) MAIN SERVICE - 2400AMP, 2081120V - LOAD CALCULATION 02-20-18 PERMIT / BID SET N1 i< PROV IJNI 1 ' „ ' EXISTING LOAD DETAIL NOTES: •k , , k. , - -, , - - - -- . , 01110- EXTEND EXISTING FEEDER TO NEW PANEL H LOCATION WITH NEC PEAK DEMAND (PUGET SOUND ENERGY) 1 - (N) 2"C-4#2/0 AL APPROVED SPLICE KIT, AND ASSOCIATED J-BOX AS REQUIRED. 02/01/17 113.6 KW x 1.25 © 0.9 P.F. = 157.8 KVA • , 200A/3 KTN-125 ,, .; o • ---c.--Eal 0 0 NEW PANEL H , -,---- ..---r: _.- • NEW LOAD , - (E) 2"C-4#2/0 AL PANEL H = 30.7 KVA 3 :=RN- lE ''': . 'EC A 5 r 2N--Y55: 5.. . • S- 5 PA'..L__ 0 ' • 1' TOR -"; P TOTAL = l::.5 KVA -ct cfc 0 2nm.• -<, '‘, '.; , 2 tk/3 <TN-'CC . 200A/3 RN- 200 4' •-- g7.--4 PANEL B ':\.. - c --0 - IT .- -.,:‘,-)P.,,,i - /5.5- EG:IP TOTAL AMPERAGE @ 208V, 3PH = 523.5 AMPS 1 i) •< ' 1.-.; .. •l.s ,<TN-I2C 42.,.),),/.3 . PN 1-591.5; SHEET TITLE: 1) , [ , 7---- PANEL A CrACE NS? f," ".,,0 1) PARTIAL RISER DIAGRAM a e , ;'-' -.~ ) 1 . ZIS gar (3) 500MCM-AL 10, LUGS PER PHASE AND NEUTRAL (800A TAP) r l' ,,...., ill KRP-C-1200 ,2 . ., . E--8.r, ,RI • - ---- -- -- r'AMr %.1 rl • • 1600A-3P , „,„ , _ -, G.E. TYPE HPC 0 SWITCH ) ,;P .1: ' 5 ' C/ , ; T SECONDARY - 2400 AMP 120/208V, 3PH, 4W : cc: SERVICE LUG PAD Cr PLC ,445 LPSE METER PROJECT ARCHITECT: --: H. #703 843 484 RAD DRAWN BY: ,f3 VAIN DISTRI1sTIO \ SWITCH3CARD - O \ .a ' LI \ ,® DIAGRAV BAA NO SCALE CHECKED BY: ALL DEVICES ARE EXISTING, SHOWN FOR REFERENCE ONLY, UNLESS OTHERWISE NOTED. JANUARY 12, 2018 ::.•7 DATE COMPUTER FILE NAME COPYRIGHT 2015 CARLETTI ARCHITECTS. P.S. +