Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit File BLD-2019-0012 1016 27th Street
i C? Cityof Anacortes Invoice/Permit#: BLD-2019-0012 904 6th Street Applied date: 01/08/2019 `"V P.O.Box 547 Issue date: 01/11/2019 • '` Anacortes, WA 98221-0547 4,7 Expire date: 07/09/2020 (360) 293-1901 Job Address: 1016 27TH ST Permit Type: Fire Alarm Permit ANACORTES WA 98221 Project: APN: Remarks: Install new fire alarm system for family center,whose building is built under permit number BLD-2018-0500. Owner: ANACORTES FAMILY CENTER Contractor: COMMERCIAL ALARM & DETECTION Address: 2702 COMMERCIAL AVE Address: 17199 BENNETT RD ANACORTES WA 98221-2734 MOUNT VERNON WA 98273-9789 Phone: Phone: (360)848-9093 License#: COMMEAI948L0 General Information: Fees: Building Valuation 18900 Building Permit Fee 307.25 Plan Review Fee 199.71 State Building Code Fee Resi 6.50 Total Calculated: 513.46 Deposits/Receipts: 0.00 Total Due: 513.46 i:r22 c n rn x- U.• t lit • T. 0 - CI C -ri c: t.t r- T: THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DPrXS :'O CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMFVqEQ; HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL PROVISI0N OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR:-Na-i`i;H GRANTING OF A PERM O OT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER' I I eCt8 LOCAL LAW REG ING CONST UCTION OR THE PERFORMANCE OF CONSTRUCT N- F-+ a it R r:4 r,,t SIGNATURE OF OWNER OR AU RIZED AGENT ISSUED BY t-'• u --o 71).)410, 1-1-1 !iTi7: . ' 13 t b - ,20 ) .? - 00 / 2, II JAN 0- 2019 N . , GOOF ANACQAG, COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT I FIRE ALARM PERMIT APPLICATION y Mailing Address:P.O. Box 547, Anacortes, WA 98221 I rk Office Location: 904 6th Street, Anacortes WA 98821 Phone: (360) 293-1901 PLEASE REFER TO THE FIRE ALARM PERMIT CHECKLIST FOR SUBMITTAL REQUIREMENTS ❑ MODIFY EXISTING SYSTEM /NSTALL NEW SYSTEM II COMMERCIAL ❑ RESIDENTIAL PROJECT ADDRESS(Street,Suite#): PARCEL(S)#: ID j i//� /C14 71// 9'ree t PROJECT V r f(3-7-C!/ APPLICANT: Phone: C'anrrr zx/i/arm Att 'hh77, 11c- _ 3 -FVd'-763 3 x /// Address(Street,City,State,Zip : Email Address: /7/` ' i7/1CY `r � /7/J7 1'y�9i 2 73 /L�`i S Gam'c iprzi.t':err-7 PROPERTY OWNER: Phone: Address Stre t,City,State; ): A�� -f,�, ,$t WA Email Address: p77107 ConmeKca/Avg ga2ai CONTACT PERSON Phone: e'r/,e S7c&LY otai--14T lS5 3 x /LX, A dress Street,City,State,Zip): I, Email Address: _ /7 1, /7/e#/rd /L kert1r7, kill 1d •73 r7i UGf9'ep ,e-on-2 C NTRACTOR:* Phone: Ctmrn /A/girl if Doke/e 7/1,1L. c5 1) - i /(� S3 3 y i'c Address S eet,City,State,Zip): Email Address /7/q i7ert . /L,7/: I G9"/76Y1/ /4 9/ 73 CXe./°%7ie_&L ii c?,p race?77 Contractor's License# Fikp.Date: *All Contractors&subcontractors must have a valid City of 1 WAIM/flild'1L6 //-jq-.21'2o Anacortes business license prior to doing work in the City. Contact Business Li ense Ex .Date: the City's Finance Department at(360)299-1968. klIlle c/ 1� -j'_ Is this work, associated with another project? Yes ❑ No C If yes,s specify: PROPOSED WORK: 2/79"aPiew , /T& Q/U217eyI ' 2 I declare under penalty of perjury that the information I have provided on this fonn/application is true,correct,and complete,and that I am the property owner or duly authorized agent of the property owner to submit a permit application to the City of Anacortes. Print Name �=Rol/tom sTG 13 Alt Owner ❑ Agent (specify): Signature: s sr-ea'— Date: itih 9 Page 1of2 rc o PLANNING, COMMUNITY, &ECONOMIC DEVELOPMENT DEPARTMENT FIRE ALARM PERMIT CHECKLIST Mailing Address:P.O. Box 547,Anacortes, WA 98221 coo` Office Location: 904 6th Street,Anacortes WA 98821 Phone: (360)293-1901 Plans shall be of sufficient clarity to indicate the location,nature, and extent of the work proposed, and conform to the provisions of the adopted International Codes and City Ordinances. PERMIT TYPE: c O SUBMITTAL REQUIREMENTS: P The number indicates the number of 2. (15 copies for submittal(if applicable). 111' O Y c 5 Fire Sprinkler Permit Application 1 1 Floor Plan(scaled construction drawings showing): 3 3 o Location of devices and appliances, end of the line devices, conduit wire runs, conduit size and number and size of devices. The zone indication shall be placed adjacent to the appropriate end of the line device o Manual fire alarm&strobes(including installation height) o Fire alarm control panel location,riser location, and control valves o Door hold-open device o Heat and smoke detectors (identify type) duct detectors o Fire alarm tamper Final inspection&approval from the Fire Marshal and Building Inspector is ✓ ✓ required once work is complete—Requested by the applicant Page 2 of 2 C, t VErACH BEFORE'PC.>:i i w c 4 ru -1V Y.r.{� ! S. YVJ+ J rll i+�.'ttl.. K � P.( I - N G.!+ RSS .l UC;'YJu�`11a[L VK. YS.(y(l 1fHf✓.y ,lRtU'F� 'J�•4�:.i1'•;N«ij 1r11.�H( .'Nf J1�V .y(�� YGY-��� ti S'��'/'� .G6w-c4`.a,.,..�c4:31.ux ..�.<u:,.mru:..:..,.o>- ....a .. :,7:7;''.u:u.'ua fihi=u.,....:s un. ..,.r «,...s.-ce. .:i.,..nst3atr�u....:lSi.i..:«.:;:- ...K..ie«aa.. :*�us,«...,.0 ms.......ni 4 , i-,:`". ir d't3 kti}. IATE OF f INGTo.N Corporation Unified Business ID #: 602389969 Business ID #: 001 Location: 0001 COMMERCIAL ALARM & DETECTION, INC. Expires: Feb 28, 2019 COMMERCIAL ALARM & DETECTION 17199 BENNETT RD MOUNT VERNON, WA 98273-9789 UNEMPLOYMENT INSURANCE - ACTIVE INDUSTRIAL INSURANCE - ACTIVE MINOR WORK PERMIT (EXPIRES 5/31/2019) - ACTIVE TAX REGISTRATION #602-389-969 -ACTIVE i? CITY ENDORSEMENTS: MARYSVILLE GENERAL BUSINESS #90930TH207 (EXPIRES 5/31/2019) - ACTIVE ANACORTES GENERAL BUSINESS (EXPIRES 5/31/2019) - ACTIVE LAKE STEVENS GENERAL BUSINESS -ACTIVE STANWOOD GENERAL BUSINESS (EXPIRES 5/31/2019) - ACTIVE BLAINE GENERAL BUSINESS (EXPIRES 5/31/2019) - ACTIVE SEDRO WOOLLEY GENERAL BUSINESS #222400 (EXPIRES 5/31/2019) - ACTIVE BELLINGHAM GENERAL BUSINESS #032208 - ACTIVE MOUNT VERNON GENERAL BUSINESS (EXPIRES 5/31/2019) - ACTIVE DUTIES OF MINORS: ASSIST TECHNICIANS WITH TESTING BY FILLING OUT PAPERWORK AND SIGNALING. ASSIST WITH OFFICE WORK AND ASSIST TECHNICIANS WITH TESTING BY FILLING OUT PAPERWORK AND SIGNALING. LICENSING RESTRICTIONS: It is the business's responsibility to comply with minor work permit requirements. See WAC 296-125-030 and WAC 296-125-033 for non-Agriculural and WAC 296-131-125 for Agricultural guidelines and restricted activities. Window washing or other work requiring worker to be positioned at higher than ground or floor level is prohibited under the age of 16. WAC 296-125-033(5)(b) rat'' II£#s �t£�#£i$£+.E'£t I£31� the 4 iT,£!;Ir<tI4UB$Sy dx'3tikib3'St?'!tTi".£TISf anti licensesxltCilFta<i;f�:tt for the �3LtS'.$£r,'SS er �t natyt d above,IN 3f.ceplit1 thi document,the licensee rertiChhi the information fan the appli ca Von s,.+ '' v'•. 7��+�J f._ was ctttaslsidste,€:r i ii,idl.ccu ate to the best of his or her knowledge,tttsti that busine s will be ama_ttctetd idz edamp3i,iixd:e with all applicable Watlilngteta state, c<s arty,and city,regulations, ...„,.. .}.,:,. s.:. .... ......... .. ....._ ......_ .. .___....._. STATE OF W'AS;•IINGTON UBI: 602389969 001 0001 Expires: Feb 28, 2019 COMMERCIAL ALARM & UNEMPLOYMENT INSURANCE- DETECTION, INC. ACTIVE COMMERCIAL ALARM & INDUSTRIAL INSURANCE-ACTIVE DETECTION MINOR WORK PERMIT (EXPIRES 17199 BENNETT RD 5/31/2019)-ACTIVE MOUNT VERNON,WA 98273-9789 TAX REGISTRATION#602-389-969- ACTIVE MARYSVILLE GENERAL BUSINESS #90930TH207 (EXPIRES 5/31/2019)- ACTIVE ANACORTES GENERAL BUSINESS (EXPIRES 5/31/2019)-ACTIVE LAKE STEVENS GENERAL BUSINESS -ACTIVE "; STANWOOD GENERAL BUSINESS , Ll 4- (EXPIRES 5/31/2019)-ACTIVE ..' 4 / -- BLAINE GENERAL BUSINESS O40Commercial Alarm & Detection, Inc. Transmittal 17199 Bennett Road • Mount Vernon WA98273-9789 Date: 01/04/2019 MP 360 848-1533 License: COMMEAI948L0 IT)q 10 rg 1.1 \Y" IT 1 'JAN 0'8 /019 ; To: City of Anacortes L , '._ Project: 18191 Permit Center C i OFANACORTES Anacortes Family Housing PH II PO Box 547 1016 27th St Anacortes WA 98221 Anacortes WA 98221 Prepared By: Sent via: Mail Item Quantity Description 1 Permit App, Plans, Spec Sheets Please sign and date this form as proof that you are in receipt of the above listed items. Return form to Commercial Alarm &Detection, Inc. Signed: Date: E i - 111* Es, �►- 1,,7 aes-corp.com ,fsecuarry CORPORATION INNOVAT1ON Vilgre0r71 LI Smart Subscribers for Commercial Fire Alarm Systems lit '') 'JAN0"a ,2019 7788F/7744F Series Fire Subscribers J Ci i Y OF ANACORTES Features • AES-Intell/Net®smart mesh radio networks are self-forming,self-healing,and highly scalable • AES-IntelliNet alarm communications technology never sunsets compared to cellular alternatives �e.RP ��r ?ti �: • Each Smart Subscriber enables multiple paths to a central monitoring station I i r+e_0/F • Option to transmit full data from FACP digital dialer to AES-MultiNet receiver � '�' • Simple and fast activation on AES-IntelliNet network rrrrrrrrrttr 'nil. Benefits rI • Most stable and profitable fire alarm communication technology • Network owner-operators retain virtually all RMR Of • Meets UL 864 Commercial Fire Alarm requirements for primary standalone communication • Ideal drop-in full-function replacement for phone lines • Universal wireless Smart Subscriber Transceivers support all new and legacy FACPs Advanced Wireless Fire Alarm Monitoring AES 7788F/7744F Series Subscribers are the ideal universal wireless communicators for any new or existing fire alarm system. AES-IntelliNet networks are built using AES Corporation's patented mesh radio communications technology.A Smart Subscriber at each alarm site acts as transmitter, receiver, and repeater of alarm signals across the network. This creates a smart long-range radio network with multiple pathways between each alarm site and the central receiver. Multiple pathways mean multiple redundancies assuring the most reliable delivery of signals and compliance with rigorous industry standards. AES-IntelliNet networks self-adjust to network changes and assure that signals automatically follow the shortest path available as the network of Subscribers grows. Highest Long Term Stability and Profitability AES-IntelliNet remains the most stable and profitable fire alarm communication technology available today in the rapidly changing world of communications. AES private wireless networks never sunset compared to cellular technology and traditional phone lines. AES-IntelliNet networks maximize RMR generated from network alarm communication services because signals are delivered without the need for a costly operations center or cellular service providers. UL 864 Edition 9 Compliant - Primary Standalone Communicators In order to meet UL approval and NFPA compliance, most fire alarm communicators require either a second communication technology or a costly service plan included with sole path cellular alternatives.With AES-IntelliNet alarm communications technology, each standalone AES 7788F/7744F Subscriber provides multiple RF pathways across the mesh radio network to the central monitoring station.To meet compliance standards, only 2 RF paths are required. Please refer to the official NFPA 72 National Fire Alarm and Signaling Code handbook, Chapter 26 (26.6.3.3.2 One-Way Private Radio Alarm Systems/Technology Reference Comparison Table A.26.6.1). Multiple RF Path Reference Guide AES provides a Multiple Path Validation Reference guide detailing how to easily validate VALIDATION multiple RF paths at each AES 7788F/7744F Series Fire Subscriber. The guide also REFERENCE provides a complete listing of the codes and standards to which AES-IntelliNet products have been tested. To assist Authorities Having Jurisdiction (AHJs)with the fire alarm inspection process,the guide and other valuable installer tools are available \ for download from the company website. Visit our Fire Marshal Resources page at (http://www.aes-intellinet.com/products/fire/fire-marshal-resources/). `A AES ._ AES-IntelliNet® Private Wireless Mesh Network Central Monitoring Station • • AES-Network Management System ''•, •• '••• Primary AES-Mul[iNe[Recent. i •. Each Smart IP Link Subscriber has multiple unique RF paths ® S2condary AES-MultsNet Recervar IP Link Alarm Automation ( 4' • AES Fire Subscriber Alarm Panel mai r ••RAFS Customer's Premise Each Smart Subscriber acts as transmitter, receiver, and repeater creating a smart long-range radio network with multiple pathways and multiple redundancies.The AES-IntelliNet network is self-forming, self-healing, highly scalable and assures that signals follow the shortest path available as the network expands. Cost Free Supervised Operation AES Subscribers offer fully-supervised operation that includes monitoring of primary and back-up operating power as well as the radio connection to the AES-IntelliNet network. Each Subscriber performs"Check-ins"with the AES central station receiver at least once every 24 hours which complies with the UL 864 standard for commercial fire alarm communications.The supervision Check-in time can be set to as often as needed for the application. Because the central station owns and Unlike cellular, there operates the long-range wireless network,there is no cost for air time to transmit supervisory signals.This is very different from cellular alternatives is no cost for air which require an aggressive supervision Check-in schedule in order to time tO transmit comply with UL 864 listing.The high monthly cost for cellular service fees significantly reduce RMR profit. supervisory signals. Full Data Module Option - Ideal replacement for Phone Lines AES Subscribers transmit consolidated alarm, trouble, and supervisory signals triggered by a FACP output relay. Subscribers with an integrated AES-IntelliPro Fire full data module transmit full alarm zone and event codes captured from a panel's digital communicator. Both options individually meet UL and NFPA 72 requirements. AES Fire Subscribers with built-in full data module are the ideal drop-in full-function replacement for phone lines for communicating signals from both new and existing UL commercial fire alarm systems. Replacing phone lines with AES-IntelliNet maximizes RMR profit with significant bottom line impact, unlike with cellular technologies that charge high monthly service fees. How to Order AES Fire Subscribers 7788F 8 Zone Fire Subscriber,8 Supervised Zones,Red Enclosure. 7744F 4x4 Zone Fire Subscriber,4 Reversing Polarity,4 Supervised Zones,Red Enclosure. 7788F-ULP 8 Zone Fire Subscriber,8 Supervised Zones,includes 7794 AES-IntelliPro Fire,Red Enclosure. 7744F-ULP 4x4 Zone Fire Subscriber,4 Reversing Polarity,4 Supervised,includes 7794 AES-IntelliPro Fire,Red Enclosure. 7788E ULP P 8 Zone Fire Subscriber,8 Supervised Zones,includes 7795 AES-IntelliPro Fire,Red Enclosure.UL listed for primary standalone communication with fire radios. 4x4 Zone Fire Subscriber,4 Reversing Polarity,4 Supervised Zones,includes 7795 AES-IntelliPro Fire,Red Enclosure.UL listed 7744E ULP P for primary standalone communication with fire radios. 7788F-C 8 Zone Fire Alarm Subscriber.ULC listed for Canada. 7788F-C-ULP 7788F-C Fire Alarm Subscriber with AES-IntelliPro Fire full data module.ULC listed for Canada. Add-on AES-IntelliPro Fire Modules 7794 AES-IntelliPro Fire Full Data Module.UL listed for supplemental communication with fire radios. 7795 AES-IntelliPro Fire Full Data Module(7794)with 7762 Hardware Supervisory Module and 7740 AES Local Annunciator.UL listed for primary standalone communication with fire radios. 7742 7762 Hardware Supervisory Module and 7740 AES Local Annunciator.7762 module provides power and supervision of the 7740 AES Local Annunciator. AES Local Annunciator 7740 7740 AES Local Annunciator.UL listed for use with 7795 module or 7742 module. Technical Specifications 7788F/7744F l e ak Backup Battery Antenna Cut/Communication • 13.25"H x 8.5"W x 4.3"D • Will charge 12V battery up to 7.5 . 12 AH, Trouble Output (34cm H x 21.5cm W x 11cm D) • Requires 12VDC 7.5 AH battery for UL 864 • Form C relay; fail secure; rated for Weight Alarm Signal Inputs (subscriber) 24 VDC 1A resistive •Approx. 7 pounds (3.2 kilograms), •7788F- 8 individually programmable zones Reset Button excludes battery •7744F - 4 individually programmable • Located on main circuit board Radio Frequency zones and 4 reverse polarity inputs Operating Temperature •Standard Frequency Range: 450-470MHz UL Stellar . • 0° to 50° C (32° to 122°F) (others available in 400-512MHz range •UL 864 Edition 9 - Standard for Storage Temperature •Output Power - 2 Watts and 5 Watts Control Units and Accessories for Fire • --10° to 60° C (14° to 140°F) to m na Alarm Systems Relative Humidity • Included 2.5 db tamper resistant antenna •UL 365 - Standard for Police Station • (} to 85% RHC, Nora Condensing mounts on enclosure Connected Burglary Alarm Units • Multiple remote antenna options available and Systems � �r input • UL 1681 - Standard for P• 16.5VAC, 40VA transformer (not included) Central Station Burglary Alarm Units (AES 1640, ELK TRG1640, MG Electronics MGT1640 -- UL Listed for use) 7794 'Transmits full data to AES-MultiNet input/Output Connections Size receiver using Contact ID or Pulse formats •AES Subscriber - data and power • 4.875" x 5"(12.3cm x 12,7cm) • Formats Supported: Contact ID, Pulse •Handheld/PC programming port Power Requirements 3+1, Pulse 4+1, Pulse 4+2, Modem Ile, •Plain Old Telephone Service (POTS) • 12 VDC nominal, primary and backup and Modem llla2 incoming phone line power provided by the AES RF •Phone output connection from Transceiver Unit alarm panel 'Trouble output(form C relay) Current Consumption 350 mA nominal 7795 7762 • P/N 40-7795 is a kit that includes 7794 g Hardware Supervisory Module module and 7762 Hardware Supervisory module. For 7794, please see Technical input tput onn u '":"`:n Size •J1 -AES 7794 (J2) or Subscriber • 2.5" x 4.9375"(6.3cm x 12.5cm) Specifications above (J1)- data and power Power input • input for Subscriber J4 Output • 12VDC nominal, power supplied • Input for AES 7740 Local from AES 7794 module or AES Annunciator - data and power 7788F/7744F Subscribers • AES 7740/AES 7794 Trouble Current Consumption Output to Subscriber input zone • 40 mA average; 100 mA peak Specifications Subject to Change Without Notice --Arm C (1US coras A Iet(.)nc LISTED About AES Corporation Established in 1974, AES Corporation empowers companies to grow profitable alarm monitoring businesses, and government agencies to enhance security anywhere in the world. By providing the industry's only patented owner operated and controlled private wireless mesh networks, AES ensures superior reliability, low Total Cost of Ownership (TCO) and optimal Recurring Monthly Revenue(RMR) while reducing dependence on service provider infrastructures, The company's flagship AES-fnteflfNet` systems are deployed in over a half million locations worldwide. For more information, go to www.aes.corp.colr or call (800) 237-6387 or contact us at sales@aes-corp.com ©Copyright 2014 AES Corporation I AES-IntelliNet is a registered trademark of AES Corporation Honeywell Farenhy tTM Series THE POWER OF CONNECTED IFP-300 / IFP-300B ___..._ Intelligent Fire Alarm Control PanelNor C The IFP-300 (red) and IFP-300B (black) are intelligent analog/addressable r fire alarm control panels (FACP) and are direct replacements for the IFP-100 FACP. The IFP-300 panel contains one built-in signaling line circuit (SLC), which can support 159 (IDP/SK) System Sensor® sensors and 159 • IDP/SK modules or 127 (SD) Hochiki® devices per loop. Additional SLC loops can be added using the model 6815 SLC expander for SK/IDP devices to increase the overall point capacity to a maximum of 300 points per panel, or model 5815XL for SD devices to increase the overall point capacity to a maximum of 254 points per panel. The IFP-300 has the interconnection capability for up to 32 panels. The system has two modes of operation, multiple panels covering one larger building, or multiple independent buildings. The SK-NIC Network Interface Card is used to network panels together. Copper wire or fiber optic cable lFP-JDOR panel connectivity can be used within the same networked system. IFP-300 has a built-in dual phone line, digital alarm communicator/ transmitter(DACT)with IP and optional cellular technologies, form-C trouble relay, and two programmable form-C relays.The IFP-300 has powerful features such as detector sensitivity, day/night thresholds, drift g 111 r compensation, pre-trouble maintenance alert, and calibration trouble alert. The IFP-300 supports a variety of devices, including RA-2000, RA-1000 or iJAN 0 r$ '2019 ► RA-100 remote annunciators, 5824 serial/parallel printer interface modules , (for printing system reports), RPS-1000 power modules, and IDP, SK, or SD cur OF ANACORTES devices. 0 Network support for Can be surface or 0 Network card allows 0 JumpStare auto n Supports Class B up to 32 Sites flush mounted copper network programming feature (Style 4) and Class A o Built-in support for up 0 Built-in USB interface connection with a foreasy (Style 6 or Style 7) to i59 I DP/SK for convenient and multi-mode or single- programming configuration for SLC, mode fiber and SBUS detectors and 159 quick programming 0 Supports up to four IDP/SK modules or connection option SWIFTS wireless 0 Built-in NAC Firmware can be 127 SD SLC devices upgraded in the field ` Built-in dual phone gateways. Each synchronization for a Four line LCD display line, digital alarm gateway can have up devices from with 40 characters per communicator/ to 49 wireless devices AMSECO Gentex', transmitter (DACT) System Sensor", and line with IP and optional Wheelock'' Available in a red or cellular technologies black cabinet IFP-300 Technical Specifications PHYSICAL: ORDERING INFORMATION Flexput'',JumpStarte, Overall Dimensions: 26.4"H x 16.4"W x 4.11"D IFP-300: Intelligent Fire Alarm Control Panel. Red Honeywell System Weight: 45 lbs. Cabniet. Sensor', and SWIFT are g registered trademarks of, Color: Red or Black IFP-300B: Intelligent Fire Alarm Control Panel and Farenhyt' is a Black Cabinet. trademark of Honeywell ENVIRONMENTAL International, Inc. Operating Temperature: 32°F to 120°F (0°C to SBUS ACCESSORIES Amseco" is a registered 49°C) RA-2000, RA-1000, RA-1000R, RA-100, trademark of Potter Electric Humidity: 0 to 93% relative humidity(non- RA-2000GRAY: Remote annunciators Signal Company, LLC. condensing) 6815: Signal Line Circuit(SLC) Expander for IDP or Gentex is a registered SK devices trademark of Gentex ELECTRICAL: 5815XL: Signal Line Circuit(SLC) Expander for SD Corporation. Hochiki' is a devices registered trademark of IFP-300 Primary AC: 120VAC @ 60 Hz, 3.3A Total Hochiki Corporation. Accessory Load: 6A @ 24VDC power-limited RPS-1000: Power Supply Wheelock is a trademark Standby Current: 190mA 5496: NAC Expander of Cooper Technologies Alarm Current: 250mA 5824: Serial/Parallel Module Company. Battery Charging Capacity: 17 to 55AH 5880: LED I/O Module This document is not Battery Size: 18AH max. allowed in control panel 5865-3 or 5865-4: LED Annunciator intended to be used for We cabinet. Larger capacity batteries can be housed in 5883: Relay Interface installationryokeepurposes.t RBB accessorycabinet. try to keep our product information up-to MISCELLANEOUS ACCESSORIES date and accurate.We AGENCY LISTINGS AND APPROVALS HFSS: Software Suite. Provides programming, cannot cover all specific NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA upload/download and event reporting applications or anticipate 72: Central Station; Remote Signaling; Local RBB: Remote Battery Box Cabinet. Use for backup all requirements.All specifications are subject Protective Signaling Systems;Auxiliary Protected batteries up to 35 AH. Dimensions: 16"W x 10" H x to change without notice. Premises Unit; &Water Deluge Releasing Service 6" D UL Listed: S2766 SK-SCK: Seismic Compliance Kit For Technical Support, CSFM: 7165-0559:0504 SK-NIC: Network Interface Card Please call 800-446-6444. FDNY: COA#6245 SK-NIC-KIT: Installation Accessory Kit FM approved SK-FML: Fiber-Optic Multi Mode, transmitter and receiver APPROVED RELEASING SOLENOIDS SK-FSL: Fiber-Optic Single Mode Asco T8210A107 24 VDC 3 A max 0 Hz CELL-MOD: Cellular Communicator in Plastic Asco 8210G207 24 VDC 3 A max 0 Hz Enclosure CELL-CAB-SK: Cellular Communicator in Metal Enclosure with lock and key COMPATIBLE DEVICES See the data sheets listed below for a complete listing of the IDP, SK, SWIFT or SD devices. 350361: IDP Device Protocol data sheet 53623: SK Device Protocol data sheet 350360: SD Device Protocol data sheet 350615 &350617: SWIFT devices data sheet Honeywell Farenhyt 12 Clintonville Road Northford, CT 06472 800-328-0103 351603 I B 109/18 HOflE?yVeIl www.farenhyt.com s:2018 Honeywell International Inc. Farenhyt �j KNIGHT by Honeywell Addressable Relay Module Agency Listings IDP-Relay / MEA u` 386-02-E Vol II The IDP-Relay is an addressable relay module for use with Q ® Silent Knight IFP-series fire alarm control panels (FACPs). The IDP-Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated 4 sets of Form C contacts, which operate as a DPDT switch. No r supervision is provided for the notification appliance circuit. /'� p�+ ;x. r The IDP-Relay contacts can be used for virtually any normally 4 _. .�"- • open or normally closed application. Each IDP-Relay is • . programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the IDP-Relay, `y', �` '.: the relay is triggered by the FACP. w;.. Features • Two sets of Form C contacts IDP-Relay • Contacts are rated for a variety of amps (see Specifications) Compatibility • Panel controlled status LED that flashes green in normal The IDP Relay is compatible with the state and is solid red in alarm following FACPs: • Relay programming is completely flexible—can be mapped to zone conditions • IFP-2000/ RPS-2000 Intelligent Fire Panel • Polling LED visible through the cover plate • IFP-2000ECS Emergency Communication System with Fire Panel • Attractive ivory cover plate • IFP-1000 / ECS Intelligent Fire Panel • Rotary address switches for fast installation • IFP-100/ ECS Intelligent Fire Panel • SEMS screws for easy wiring • IFP-50 Intelligent Fire Panel • UL Listed • IFP-25 Intelligent Fire Panel Relay Contact Ratings Current Load Installation RatingMax Voltage Description Application The IDP-Relay mounts directly into a 4" 3 A 30 VDC Resistive Noncoded square electrical box.The box must have a minimum depth of 2-1/8". A surface mount 2 A 30 VDC Resistive Coded electrical box (System Sensor® PN SMB500) 0.7 A 70.7 VDC PF=0.35 Noncoded is available from Silent Knight. 0.9 A 125 VAC Resistive Noncoded - [E ( NUTT 0.46 A 30 VDC L/R=20 ms Noncoded 0.5 A 125 VAC PF=0.75 Noncoded JAN 0 -2019 0.3 A 125 VAC PF =0.35 Noncoded °l l Y OF ANACORTES 2 A 25 VAC PF=0.35 Noncoded P/N 350290 Rev J ©2015 Honeywell International Inc. CONNECT MODULES TO LISTED COMPATIBLE (-) CONTROL PANELS ONLY. (-) FROM PANEL TO NEXT ...1( OR PREVIOUS DEVICE (+) (+) DEVICE RELAY CONTROL MODULE I 1 If any wiring to Terminals 4-10 is ,, Nonpower limited,The CB500 barrier llit O O Cb is required.The CB500 includes a T� Nonpower limited label,which � e d F must be placed over the Power IT11 0 Limited terminal information on Relay Common 2rtp rt ( ) the name plate label. Normally Closed 2r9 T2 (+) Normally Open 2T8 T3 Relay Common 1T7 7 7 . T4 Unused Normally Closed 1re 3�s 3 rs Normally Open 1 1010 10 d _ TENS 9 OtS IORES$�J�') NOTE:ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN Low A SEPARATE ZONE. 11 11 Specifications Ordering Information Physical IDP-Relay Relay Module 4.675" H x 4.275" W x 1.4" D Shipping Weight: 6.3 oz (196 g) , Accessories Environmental SMB500 4" Square Surface Mount Electrical Box Operating Temperature: 32°F— 120°F (0°C—49°C) CB500 Module Barrier Humidity: 10%—93% non-condensing Electrical Operating Voltage: 15—32 VDC End-of-Line Resistance: Not used SLC Standby &Alarm Current: .255mA max @ 24 VDC (one communication every 5 sec with LED enabled) it SILENT This document is not intended to be used for installation purposes.We try to keep our 011 product information up-to-date and accurate.We cannot cover all specific applications or NI KNIGHT anticipate all requirements.All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road,Northford,CT 06472-1610 Phone: sm."1""""""1.0 byHoneywell (800)328-0103, Fax: (203)484-7118.For Technical Support, Please call Assembled in the Y 800-446-6444. www.farenhyt.com U.S.A. •C,m (0 -IU 1 Y7 fl ` JAN O'O �019 SILENT F arenhyt i M"N Y Idi 10 KNIGHTf OF ANACORTES by Honeywell ell Intelligent Power Module Agency Listings MEA 5496 �`" �.� The 5496 intelligent power module by Silent Knight is the most �) Cir!,cost-effective power supply available today. It delivers 6 amps of 4k" 429-92-E Vol.XIV notification appliance circuit power and built-in synchronization for appliances from System Sensor°,Gentex°, Faraday,AMSECO, System Sensor, and Wheelock®. The 5496's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. The 5496 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with Silent Knight IFP-Series fire alarm control t(i) panels (FACPs). The 5496 is the cost-effective solution for powering notification appliances required by the Americans with Disabilities Act(ADA). The 5496 has built-in ANSI cadence pattern. The output circuits can be programmed as notification appliance circuits, or as auxiliary power(configurable for constant, resettable, or door holder power). SII I:YT Features K"NT • UL Listed for 6 amps of notification power • Power supply's advanced switch mode design reduces 5496 Intelligent Power Module damaging heat and manages power up to 50% more efficiently Installation than other systems The 5496 cabinet is surface mounted. • Built-in synchronization for appliances from Gentex, Faraday, AMSECO, System Sensor, and Wheelock • 24 VDC filtered output voltage Compatibility The 5496 is compatible with the following • Four power-limited notification outputs; 2 Class A or 4 Class B, FACPs: or 1 Class A and 2 Class B • NACs are programmable as notification appliance circuits, or as • IFP-2000/ RPS-2000 Intelligent Fire auxiliary power to be used as constant, resettable, or door Panel holder power • IFP-2000ECS Emergency • 3 amps per output circuit Communication System with Fire Panel • Ground fault detector • IFP-1000 / ECS Intelligent Fire Panel • Communicates to the FACP via 4-wire SBUS (wire runs up to 6000 ft) • IFP-100/ ECS Intelligent Fire Panel • AC loss delay option shuts off power to non-essential high- • IFP-50 Intelligent Fire Panel current accessories like magnetic door holders • Lightweight design adds to ease of installation and reduces shipping costs • ANSI Cadence pattern output capability built-in • UL 864 & 1481 listed • CSFM approved • MEA approved P/N 350302 Rev F ©2015 Honeywell International Inc • OSHPD (CA) OSP-0065-10 (see accessories) Gentex°is a Registered Trademark of Gentex Corporation. System Sensor®is a Register Trademark of System Sensor.Wheelock°is a Registered Trademark of Wheelock, Inc. 4 Outputs Programmable as Notification Appliance Circuits, or as Auxiliary Power Output 1 -411111 SBUS Communication To a Compatible Out ut 2 - Silent Knight FACP p • ,, , Ow. Output 3 44 Output 4 - - �snfxr �y�kAft.fif Auxiliary Power Can Be Programmed To Be Constant, Resettable, or Door Holder Power Specifications Environmental Physical Operating Temperature: 32°F to 120°F (0°C to 49°C) Height: 16" (40.6 cm) Humidity: 10% — 93% non-condensing Width: 12.25" (30.9 cm) Ordering Information Depth: 3" (7.6 kg) 5496 Intelligent Power Module Shipping Weight: 8.7 lbs. (3.9 kg) RBB Remote Battery Box Electrical Accessories: AC Input: 120 VAC at 2.7A SK-SCK Seismic Compliance Kit Output: 24 VDC at 6A Standby & Alarm Current: 10 mA Notification/Aux. Power Circuits: 4 Output Configuration: 2 Class A (Style Z) 4 Class B (Style Y) 1 Class A & 2 Class B Amps Per Output Circuit: 3.0 (6.0 amps total) Notification Circuit Output: 20.4 — 27.3 VDC @ 3.0A each End-of-Line Resistance: 4.7k SI EOL resistor required on each Class B circuit Battery Charging Capacity: 7.0 — 35.0 AH Ell SILENT • •NIGHT This document is not intended to be used for installation purposes. We try to keep our ;•:•:�,•:•' -- K product information up-to-date and accurate. We cannot cover all specific applications . . . • . or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472- 1610. Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, please call byHoneywell Assembled in Y 800-446-6444. www.farenhyt.com America -OE [E FS \\11 "Ti SILENT 'JAN 0 43 2019 II 41011 KNIGHT Fa renhyt Ci I OF ANACORTES by Honeywell Intelligent Devices Intelligent Photoelectric Smoke Detector & Photoelectric Smoke with Thermal M EA (Or UL 225-02-E Vol.V IDP-Photo, IDP-Photo-T and IDP-PhotoR The IDP-Photo is a photoelectric smoke detector and the IDP-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IFP-series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to b �.- the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. IDP-Photo(Base not Included) IDP-Photo and IDP-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a Installation wide range of combustion sources. In the IDP-Photo-T, dual The IDP-Photo and IDP-Photo-T plug into a electronic thermistors add 135°F (57°C)thermal technology to compatible IDP-series detector base. The maximize detection. IDP-PhotoR is a remote test capable detector The IDP-PhotoR is a remote test capable detector for use with for use with the DNR (W) duct smoke the DNR (W) duct smoke detectors. It is UL 268A listed when detector. used with the DNR (W) duct smoke detector. Compatibility Features The IDP-Photo, IDP-Photo-T and IDP-PhotoR • Sleek, low-profile design are compatible with the following IDP-series • Reliable analog communications for trouble-free operation detector bases: • • Age resistant polymer housing B210LP 6" Mounting Base • • Dual electronic thermistor design on the IDP-Photo-T B501 4" Mounting Base • B224B1 6" Isolator Base • Superior EMI resistance for reliability • B224RB 6" Relay Base • Simple field cleaning for code compliance • B200SR 6" Sounder Base • Variety of mounting options to meet any application The IDP Photo, IDP-Photo-T and IDP-PhotoR • Dual LED indicators for 360°visibility are compatible with the following FACPs: • Detector transmits signal to indicate maintenance is • IFP-2000/ RPS-2000 Intelligent Fire Panel required • IFP-2000ECS Emergency Communication • Optional remote LED annunciator (System Sensor® PN System with Fire Panel RA100Z) • IFP-1000 /ECS Intelligent Fire Panel • Plug-in mounting provides ease of installation • IFP-100/ ECS Intelligent Fire Panel • Tamper-proof feature available on mounting bases • IFP 50 Intelligent Fire Panel • Listed for use in duct applications • IFP 25 Intelligent Fire Panel • Rotary address switches for fast installation • UL Listed P/N 350280 Rev H Copyright©2017 Honeywell International Inc. SLC OUT IN I PA II a: Compatible FACP + RA10OZ(Optional) I -- r I .".4e\p, as•\ I Class A Optional Wiring Wiring IDP-Series Detector Mounting Bases Wiring IDP-Series Detector Mounting Bases Specifications* Ordering Information Physical Height: 2.0" (5.0 cm) IDP-Photo Photoelectric Smoke Detector IDP-Photo-T Photoelectric Smoke Detector with Diameter: 4.1" (10.4 cm) installed in B501 base Thermal (135°F) Electrical IDP-PhotoR Photoelectric smoke detector, remote Operating Voltage: 15-32 VDC test capable, for use with DNR (W) duct SLC Standby and Alarm Current: 300 pA smoke detector Environmental Accessories Operating Temperature RA100Z Remote LED Annunciator. IDP-Photo: 32° — 120°F (0°C — 49°C) XR2B Detector Removal Tool. A removal and IDP-Photo-T: 32° — 100°F (0°C — 38°C) replacement tool for IDP plug-in detectors. Includes the T55-127-000. Humidity: 10% — 93% non-condensing M02-04-01 Detector Test Magnet. Other Ratings IDP-Photo-T Thermal: Fixed temperature setpoint 135°F M02-09-00 Test Magnet with Telescoping Handle. (57°C) XP-4 Extension Pole for XR2B. Extends from Velocity: 0 — 4000 fpm (0 — 20 m/sec) (suitable for 5 — 15 ft. installation in ducts) T55-127-000 Detector Removal Head. IDP-Photo Insect Screen Hole Size: 0.016" (0.41 mm) BCK-200B Black Detector Kit. For IDP-series nominal detectors. * Unless otherwise noted, specifications apply to IDP-Photo and I DP-Photo-T. SILENT This document is not intended to be used for installation purposes. We try to keep our product information up- to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications ti KNIGHT are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. by Honeywell For Technical Support, Please call 800-446-6444. www.farenhyt.com JAN 0�$ �010 � 10LENT Fa renhytxT CI i Y OF ANACORTES by Honeywell Addressable Single Action and Dual Action Agency Listings Pull Stations M EA IDP-Pull-SA & IDP-Pull-DA 011131 67-02-E Vol.IX The IDP-Pull-SA is a single action pull station requiring only one rcvif, For IDP-Pull-DA motion to activate the station. The IDP-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight IFP-series fire alarm control panels (FACPs). FIRE Features PULL • Installer can open station without causing an alarm condition 1 DOWN 4 • Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks 496 SILENT KNIGHT • Meets the Americans with Disabilities Act Accessibility ao Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) IDP-PuII-SA • Meets ADA requirement for 5 lbs maximum pull force to active t • Shell, door, and handle molded from durable LEXAN® FIRE • Reliable analog communications for trouble-free operation • Braille text on station handle • Handle latches in down position and the word Activated I PUSH IN appears, clearly indicating the station has been pulled i PULL DOWN 1 • Rotary address switches for fast installation • UL Listed, including UL 38, Standard of Manually Actuated Signaling System Installation SIILNT z. KNIGHT ,10 The IDP-Pull-SA and IDP-Pull-DA can be surface mounted to an a ,) SB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm) or double- IDP"Pull-DA gang or 4" (10.61 cm) square electrical box.You can also use the optional (System Sensor® PN BG-TR)trim ring if the station is • IFP-100/ ECS Intelligent Fire Panel being semi-flush mounted. • IFP-50 Intelligent Fire Panel Compatibility The IDP-Pull-SA and IDP-Pull-DA are compatible with the following FACPs: • IFP-2000/ RPS-2000 Intelligent Fire Panel • IFP-2000ECS Emergency Communication System with Fire Panel • IFP-1000/ ECS Intelligent Fire Panel P/N 350286 Rev G ©2015 Honeywell International Inc i • / e ,. - ir `. Class A '.:1. ...i i fS p OUT : , * i / • ; — Class B Compatible FACP ( I l I ii 1 , Il IMu1 ):__.e,;-`ri+:ar.s , B [.�.�: ... .e I..",. 1 I4, ,i 'r lam. Class A Wiring: Class B Wiring: -- - i _-._. .. ` _...-. ._ ...-.. •s:_ __-._____. .-_..._._....-._ _i_jam Wiring IDP-Pull-SA& IDP-Pull-DA Pull Stations Specifications* Ordering Information Physical IDP-Pull-SA Single Action Pull Station Height: 5.5" (14 cm) IDP-Pull-DA Dual Action Pull Station Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Accessories BG-TR Optional trim ring. Housing Material: LEXAN polycarbonate resin SB-I/O Surface backbox, indoor/outdoor. Bi-Colored LED: Blinking Green: Normal * Unless otherwise noted, specifications apply to IDP-Pull-SA and IDP-Pull-DA. Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC SLC Standby and Alarm Current: 350 pA Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 32° — 120°F (0°C — 49°C) Humidity: 10% — 93% non-condensing SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All KNIGHT specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. i_> For Technical Support, Please call 800-446-6444. www.farenhyt.com by Honeywell N117r-lr' l ) �JAN 0-8 2019 SILENT Farenhyt KNIGHT Ci TY OFAN by Honeywell Intelligent Device Addressable Monitor Module Agency Listings IDP-Monitor (�ST,M M EA The IDP-Monitor is an addressable monitor module for use with 0, k v t 386-0-E-Vol 2 Silent Knight IFP-series fire alarm control panels (FACPs). The IDP-Monitor acts as an interface to contact devices, such as waterflow switches and pull stations. 1/ The IDP-Monitor supports Class A supervised or Class B r supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. i,-. Features • Single contact monitor • Support for Class A and Class B wiring IDP-Monitor • Fully supervised Compatibility • Panel controlled status LED that flashes green in normal state The IDP-Monitor is compatible with the and is solid red in alarm following FACPs: • Attractive ivory cover plate • Rotary address switches for fast installation • IFP-2000/ RPS-2000 Intelligent Fire Panel • SEMS screws for easy wiring • IFP-2000ECS Emergency Communication • UL Listed System with Fire Panel • IFP-1000 / ECS Intelligent Fire Panel Installation • IFP-100/ ECS Intelligent Fire Panel The IDP-Monitor mounts directly into a 4" square electrical box. • IFP-50 Intelligent Fire Panel The box must have a minimum depth of 2-1/8".A surface mount electrical box (System Sensor®PN SMB500) is available from Silent Knight. P/N 350288 Rev J Copyright©2015 Honeywell International Inc. {-) t� TO NEXT ..? — FROM PANEL-OR DEVICE .� (*0 IOW s►+ +ta �n ■► ► (-0 PREVIOUS DEVICE MONI TOR ANY NUMBER OF UL LISTED CONTACT fl MODULE (--t CLOSURE DEVICES MAY BE USED. DO NOT MIX ,- CONNECT MODULES TO LISTED COMPATIBLE FIRE ALARM INTIATINO, SUPERVISORY. OR 010 I , ib 0 CONTROL PANELS ONLY SECURITY DEVICESON THESAMEMODULE. e = I- � '"_-ice t ) 47K EOL I l I' ..L I RESISTOR __ i' ` ,_ ' . ELR-47K I, A TON c ciw q01109= INITIATING DEVICE CIRCUIT(IDC)-NFPA STYLE B C3 © ALL WIRINGSHOWN IS SUPERVISED AND POWER LIMITED POWER LIMITED: 4501.1A MAX. a; H VDC MAX INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURERS INSTALLATION INSTRUCTIONS. Typical Wiring for IDP-Monitor Module, NFPA Style B TO NEXTtyl C3�C�C7CXJ� t1""� FROM PANEL OR DEVICE ,,,c l3I -'�-r `•% PREVIOUS DEVICE MONITOR ANY NUMBER OF UL LISTED CONTACT MODULE 0 01 CLOSURE DEVICES MAY BE USED.DO NOT MIX CONNECT MODULES TO LISTED COMPATIBLE FIRE ALARM INT IATING, sUPERVISORY,O:? 0 O d 'b CONTROL PANELS ONLY SECURITY DEVICES ON TFIE SAME MODULE. H . =31_ ri c-1 sx (+) \ C \ T EOL RESISTOR IS 1 I ems INTERNAL "' ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED TERMINALS 8&9 t INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. Typical Wiring for IDP-Monitor Module, NFPA Style D Specifications Environmental Physical - Operating Temperature: 32°F — 120°F (0°C — 49°C) Height: 4.5" (11 .4 cm) Humidity: 10% — 93% non-condensing Width: 4" (10.2 cm) Ordering Information Depth: 1 .25" (3 cm) IDP-Monitor Monitoring Module Shipping Weight: 6.3 oz (196 g) Accessories Electrical SMB500 4" Square Surface Mount Electrical Box Operating Voltage: 15 — 32 VDC SLC Standby and Alarm Current Draw: 350 pA End-of-Line Resistance: 47K 0 Max. IDC wiring resistance: 1 ,500 Q Max. IDC Voltage: 11 Volts Max. IDC Current: 450 pA SLC Loop Resistance: 40 Q. max. I:21 SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are KNIGH1 subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. by Honeywell For Technical Support, Please call 800-446-6444. www.farenhyt.com -I \vi rA , , „ t, c(c , TCTTERt JPN 4 RTS0/RTSC _ % - Room Temperature Switch _ The Symbol of Protection ' OF ANA�O Features • Easily installed • Completely sealed sensor, moisture and vapor resistant • Highly resistant to vibration and corrosion • Highly sensitive to temperature changes • No sensitivity loss due to aging 401, • Repetitive operation without the need to replace sensing elements • Small compact design • Precision and quality at low cost SIGNALING c US LISTED Important: This document contains important information on the installation and operation of room temperature switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. Description Technical Specifications Each unit consists of a bi-metal operating mechanism, featuring Enclosure White ABS hermetically sealed precious metal contacts, N.O. or N.C., which automatically reset for repetitive operation, eliminating the need for Dimensions 2 1/16"W x 3 7/16"L x 1 1/4"H sensing element replacement. (5,2cm W x 8,7cm L x 3,2cm H) Small compact design, highly resistant to vibration and corrosion. Sensor Epoxy sealed stainless steel case, bi-metallic Easily installed using the enclosed hardware or adhesive mounting operating mechanism. pad. Contacts Silver clad, available normally open or normally Screw terminals permit easy installation in single or multiple closed detector circuits. Electrical 1 Amp at 24VDC Rating Application Temperature 40° ±5°F (4,5° ±3°C) Setting The RTS Series complies with the requirements of NFPA 13 and 72 for a room temperature switch to operate at 40°F to protect a dry pipe Terminals Screw Terminals valve from freezing. The RTS can also be used for other temperature Mounting Wall Mount, Surface detection applications. Operation The normally open detector, RTS-O, will close the contact when the temperature drops below 40°F (4,5°C). The normally closed detector, RTS-C, will open the contact when the temperature drops below 40°F (4,5°C). The detector will automatically reset to the normal state when the temperature rises above 40°F (4,5°C). The RTS Series Room Temperature Sensors are precision engineered, designed and manufactured for commercial or residential use. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-0988 / Canada 888-882-1833 • www.pottersignal.com 5401019-REV H • 09/15 PAGE 1 OF 2 P POTTER RTS -O/RTS-C The Symbol of Protection Room Temperature Switch Inspection, Testing, & Maintenance The frequency of inspection and testing of the RTS and its associated monitoring system shall be in accordance with applicable local and NFPA codes and standards. Manufacturer recommends quarterly or more frequently. Functional test can be accomplished by spraying the RTS with circuit cooler or equivalent. More accurate test requires exposing the RTS to 40°F± 5°F. The RTS requires no maintenance other than ensuring the vent holes are not obstructed. Fig I RTS-0 RTS-0 0 Control Unit Supervisory Device EOLR Circuit 0 RTS-C RTS-C 0 O O 0 0 Control Unit Supervisory Device EOLR Circuit 0 DWG#1019-1 NOTE: This RTS does not have duplicate terminals. Do not use looped wire under terminals. Break wire run to provide supervision of connections. RTS Mounting Template Ordering Information Fig 2 Model Description Stock No. r - RTS-0 Normally Open Room Temperature 1010108 i. a O Switch 40 RTS-C Normally Closed Room Temperature 1010109 0 O _ O O i Switch DO a NOTICE Supervisory switches have a normal service life of 10-15 years. I 0 0 I However, the service life may be significantly reduced by local O _ 0 environmental conditions. 411 0 0 J T Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-0988 / Canada 888-882-1833 • www.pottersignal.com 5401019-REV H • 09/15 PAGE 2 OF 2 ._ •SYSTEM .I.1.1.1. , r 1. ,1 It_,:- , i. .._, SENSOR' .1.1.1. 1. ( ., , ,. 4 ` ,- I # I I g -i'i: :ia : I Indoor Selectable- 1, I,.L a 1 ,,.. .., ;,-. , - 3 t llorns, ,�� Y ,,1 i I#,3 Eftutpu EStrobes, and , . ' : I ' I ' i Horn Strobesfor . _ Y ' - i . 4e,_ : Wall Applications �:'1 11 4 System Sensor L-Series audible visible notification i; 3 : } products are rich with features guaranteed to cut 8 _- ,„1 : i -;Y µ: installation times and maximize profits with lower ;` l_ current draw and modern aesthetics. --_.. _-- 7: Features z. • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns, strobes, and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics, With white and red plastic housings, standard and compact devices, and plain, FIRE, • Tamper-resistant construction and FUEGO-printed devices, System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns, strobes, and horn strobes 15, 30, 75, 95, 110, 135, and 185 include a variety of features that increase their application versatility • Horn rated at 88+ dBA at 16 volts while simplifying installation. All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming a Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage, the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring, so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed, • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings \\R 1 L 1 SIGNALING a (2) 441> ,----.::: , .:::1' 7 .hv LISTED APPROVED fJ , 0 f$ 2019 i S5512 FM approved except 7125-1651:0504 \'''OTE Il JAN S4011 for ALERT models 7135.1G53:0503 11 3057383,3057072 AVDS8S5-05.2/22/2018•Page 1 (11 Y OF ANACO T F_S L-Series Specifications Architect/Engineer Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box, 4 x 4 x 11/cinch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•CircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize Strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 1.91""D (143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D (143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D (133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05•2/22/2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current e • - A l; p mall Horn Strobe' ela Range(15-185`cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157- 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 "Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVDS865-05•2/22/2018•Page 3 L-Series Dimensions _ 1 1.91" L- 3.46" 3.46° r1 48.5 mm 88 mm 1 = = 1.25" 3,57" 1.55° 86 mm 1 - - 1.25" 32 mm (9.1 cm) (3.9 cm) �� 32mm t it / �, r I ri,.... i ,:.'" im -0000000 0000 0 0If m In UP 0100 001p8 0 000000000000 r 010040 000000 5.27" .1.1.1.161.1. 0 0 0Oop0000 5.38" IL 133.9 mm _ Il' 5.27" p0p0p0p0p0pp (13.7 cm) r � imdi 133.9mm OpDpOpOpOpOp 0 r , 1111 0 7 11 ° r > A0548-00 A0547-00 A0557-00 Compact Strobe, Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL, SBBGWL 4.70" T (11.94 cm) 1.91" T 4.7" y (4,85 cm) = E 3= 1.25" 4.82" — I • 119 mm 32 mm r — (12.24 cm)1.25" ._ . IJ (3.18 mm) � ;1 �l 4 I _ IJ � (4.69 cm) U? 10141141/0/ iI1:P;i1T 0111111��1 ' 5.78° 5.67„ ...a . rI 5.67 000 ;t4.ssc m) O b(14.4 cm) II 144 mm oao.i _ 0 d _ A0550-00, A0549-00 A0554-01 Strobe, Horn Strobe Horn Wall Surface Mount Back Box SBBRL/SBBWL L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns* P2RL 2-Wire, Horn Strobe, Red HRL* Horn, Red P2WL 2-Wire, Horn Strobe, White HWL* Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HGRL* Compact Horn, Red P2GWL 2-Wire, Comp 2 fils act Horn Strobe, White HGWL* Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBRL Wall Surface Mount Back Box, Red P4RL 4-Wire, Horn Strobe, Red SBBWL Wall Surface Mount Back Box, White P4WL 4-Wire, Horn Strobe, White SBBGRL Compact Wall Surface Mount Back Box, Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box, White SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All-P models have a plain housing (no "FIRE" marking on cover). All-SP models have "FUEGO" marking on cover. All-ALERT models have "ALERT" marking on cover. *Horn-only models are listed for wall or ceiling use. '7E 3825 Ohio Avenue • St. Charles, IL 60174 ©2018 System Sensor. Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice.Visit systernsensor.com SEIL.c !?n for current product information,including the latest version of this data sheet. www,systemsensor.com AVDS865-05.2/22/2018 SYSTEM ,,,,......4 SENSOR® ....s_. . ...._ , --- -- - Selectable-Output , _Low Frequency ! _ _ __,......._ Sounder and Low , _ _____ ___ Y __ FrequencySounder 1 _ . f; , R 'itt , .*::: 1 1 , - ' R Strobes for Wall ,. 1 E ,. Applications 4 R SPECTFIert SpectrAlert°Advance audible visible notification products A. a from S stem Sensor are rich with features guaranteed to cut installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of low frequency sounder and low frequency • 520 Hz ± 10% square wave tone sounder strobes in the industry. With white and red plastic housings, • Plug-in design with minimal intrusion into the back box dual listed for wall and ceiling mounting, SpectrAlert Advance can • Tamper-resistant construction meet virtually any application requirement. • Field-selectable candela settings on wall units: The wall-mount low frequency sounder, and low frequency sounder 135, 150, 177, and 185 strobes were designed to address the NFPA 72 sleeping space • Rotary switch for low frequency sounder tone requirements that require a low frequency notification appliance that • Universal mounting plate for wall units operates within frequency range of 520 Hz ± 10% and is of a square wave tone. Like the entire SpectrAlert Advance product line they • Mounting plate shorting spring checks wiring continuity before include a variety of features that increase their application versatility device installation while simplifying installation. All devices feature plug-in designs • Electrically compatible with legacy SpectrAlert devices with minimal intrusion into the back box, making installations fast • Compatible with MDL3 sync module and foolproof while virtually eliminating costly and time-consuming • Listed for ceiling or wall mounting ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, Agency Listings automatic selection of 12- or 24-volt operation, and a rotary switch for 520 Hz low frequency sounder tones. SIGNALING ft - (DO 41;* 'f.O` ' tt ii MEA *_,.. \VI I 5 ILISTED APPROVED approved S4011 (sounder) 3047563 MEA452-05-E 7135-1653:0223 JAN O'8 ' GUY Or Nvi-kuki I.E.b SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•CircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings including 135, 150, 177, and 185. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone and have a permanent marking on the housing that reads "low frequency sounder". Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for fire protective service. The low frequency sounder and the Sync•CircuitTM MDL3 Module accessory, if used, shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts (includes fire alarm panels with built in sync). When used with the Sync•Circuit Module MDL3, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three pattern, non-temporal (continuous) pattern and coded supply within the frequency range of 520Hz ± 10% square wave tone. The low frequency sounder shall operate on a coded or non-coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes, the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 411A6 x 411/16 x 2'/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Frequency Range 520 Hz ± 10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 DC/FWR or regulated 24 DC/FWR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (162 mm L x 119 mm W x 64 mm D) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inches D (142 mm L x 119 mm W x 33 mm D) Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D Dimensions (SBBR, SBBW) (162 mm L x 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D (SBBR, SBBW) (145 mm L x 120 mm W x 76 mm D) Notes: 1, Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. UL Current Draw Data UL Max.Low Frequency Sounder Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal 3 High 191 262 138 166 Continuous High 292 384 138 208 Coded High 292 388 153 205 UL Max.Current Draw(mA RMS),2-Wire Low Frequency Sounder Strobe,High Candela Range 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal 3 277 292 325 344 Temporal 3 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 • Low Frequency Sounder Tones and Sound Output Data Low Frequency Sounder and Low Frequency Sounder Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Volts Volts Reverberant Anechoic Switch Position Sound Pattern DC FWR DC FWR DC FWR DC FWR 1 Temporal 3 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 3t Coded 80 80 80 80 80 80 90 90 t Sounder ratings provided are for continuous voltage as provided by the NAC SpectrAlert Advance Dimensions 4.7 in. ► 2.5 in. ► • 4.7 in. ►l �1.3 in A NM �1 � NBT-PANT--_ r DO NOT PANT II / N. II n-7 \—rl -- I,/ tilt I. III III (; 1l Ill 111 I II Z\ n, /v i I/ Al u I. v i III) rl -_`- t I I 11 1 51 \ [� \I' l � , 6.4 in. it It '� 5.6 in. 1 , � i I ` ft l LI 1u1i _}1 C LOW Ff'EOUB.CY SOUNDE 1 1 r _-� OO _ ® �__ Wall-mount low frequency sounder strobes Wall-mount low frequency sounder SpectrAlert Advance Ordering Information Model Description • Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe, High cd, Red P2WH-LF 2-Wire Low Frequency Sounder Strobe, High cd, White Low Frequency Sounders HR-LF Low Frequency Sounder, Red HW-LF Low Frequency Sounder, White Accessories SBBR Surface Mount Back Box, Wall, Red SBBW Surface Mount Back Box, Wall, White TR-HS Trim Ring, Wall, Red Notes: "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. ` $y5E 3825 Ohio Avenue • St. Charles, IL 60174 ©2015 System Sensor. 7pJ7 Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com ._ SENSOR www.systemsensor.com for current product information.including the latest version of this data sheet. AVDS16404. 1/15 SYSTEM 4 SENSOR® • 5600 Series auxd -- Mechanical Heat 5601P Detectors 44, \ System Sensor's 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. 135 Fe 5 3 `` 5621 Features Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both • Multiple configurations for installations: single- and dual-circuit models are available for low- and high- -Single- and dual-circuit models temperature ratings with either fixed temperature or combination - Fixed temp and combination fixed- temp/rate-of-rise fixed temperature/rate-of-rise (ROR) activation. The ROR element of 135°F or 194°F ratings. the fixed/ROR models is restorable to accommodate field-testing. • Plain housing for residential installations (Model 5601P) • Easy-to-use terminal screws Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back • A broad range of back box mounting options: boxes. And these models accommodate four-square back boxes, -Single gang when used with a square to round plaster ring. The reversible -3.5"and 4"Octagonal mounting bracket permits both flush- and surface-mount back box -4"square with square to round plaster ring installations. • Reversible mounting bracket Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/ rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. Agency Listings IIqy/ i JN0 2019 GIO 41/: LISTED APPROVED S2101 3016008 CS630 7270-1653.0167 C +� O i= A \ A(( P _P:F Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number , listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601 P, 5603, 5621, and 5623: 100°F(38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601 P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601P, 5602, 5621, and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage/Contact 6-125VAC /3A Ratings 6-28VDC / 1A 125VDC /0.3A 250VDC /0.1A Input Terminals 14-22 AWG naLici 0 0 0 0 i/ k 1 \ ‘ DIY 5601 P 5602, 5622 5603, 5623 5604, 5624 5621 Ordering Information Identification Method Temperature UL Protected Spacing- 10 Foot Model Circuit on Exterior Rating Activation Ceiling* 5601P Single None 135°F (57°C) Fixed Temperature/ Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194°F (90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135°F (57°C) Fixed Temperature/ Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature/ Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 5y571JI7 3825 Ohio Avenue • St. Charles, IL 60174 ©2013 System Sensor. SENSOR' Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice.Visit systemsensorcom for current product information,including the latest version of this data sheet. www.systemsensor.com SPDS30001•7/13 1--0.1E g EE g wi ) Th, SYSTEM JAN o r.8 -2019 , 41001111.1111111111b- \,..,, ), SENSOR® CITY OF ANACORTES j 1M, Outdoor Selectable- Output Horns, 111Strobes, and Horn Strobes for Wall Applications SPECTFIert SpectrAlert®Advance outdoor audible visible products f Ar o System `Sensor are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic • Weatherproof per NEMA 4X, IP56 housings, wall or ceiling mounting options, and plain or FIRE-printed • Listed to UL 1638 (strobe) and UL 464 (horn) devices, SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement, including indoor, outdoor, wet, and dry applications in legacy SpectrAlert products temperatures from -40°F to 151°F. • Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, Like the entire SpectrAlert Advance line, outdoor horns, strobes, 135, 150, 177, and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12- or 24-volt operation at 15 and that increase application flexibility and simplify installation. First, 15/75 candela field-selectable settings, including candela, automatic selection of • Rotary switch for horn tone and three volume selections 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. • Horn rated at 88+ dBA at 16 volts • Rated from -40°F to 151°F Next, SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications. This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without • Plug-in design with minimal intrusion into the back box mounting the devices and exposing them to potential construction • Tamper-resistant construction damage. Once the plates are mounted, all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- Agency Listings out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion. Knock-outs located on the back eliminate the need to drill on: holes for screw-in mounting. Plastic and metal weatherproof back kv� . boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch LISTED(g) MEA 7125-1653:188(ho-1653:187 rn(outdoor ties) knock-outs at the back. A screw-in NPT plug with an 0-ring gasket S4011 (chimes,horn strobes,horns) APPROVED approved chime strobes) S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•CircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts, When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F (-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7"W x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6""L x 4.7-W x 1.3""D (142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7"L x 5.1-W x 2.0""D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01 201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output(dBA) IIMMiliallilidMIM candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDSo12o1 SpectrAlert Advance Diagrams r 4.7" 01 2.5" r ■�� Are \--. ����\� 0o ror mart ` I / f IIII 5.6" tO O 4 Int 4 � 1111 -- -- ---- fr-N,„,.....4' 0 / 0....... ii w _..y :.—� Wall-Mount Horn Strobes _\ � Wall Plastic Weatherproof Back Box klowii\ .,_":‘....7 __ 1 ., � �°�® 0I i1I ,.........,. ; �I . " 4 -, .r VW '.� fte Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK*t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK"t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*t Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: *Add "-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R"to model number for weatherproof replacement device(no back box included), only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. *� STEM ©2012 System Sensor. 3825 Ohio Avenue • St. Charles, I L 60174 Product specifications subject to change without notice.Visit systemsensor.com ��)' SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 for current product information.including the latest version of this data sheet. AVDS01201 •3/12 _ — - _.... CABLE.CODES SLC POINT LIST U _ CODE FUNCTION DESCRIPTION NECTYPE CABLE ROUTING POINT NUMBER LOCATION NAME DESIGN CRITERIA SLC SIGNAL LINE CIRCUIT 1-2/C #16 AWG FPLR CONDUIT OR OPEN RACEWAY • , 33:m001 FIRE SUPPRESSION/ELEC ROOM PULL STATION DESIGNED PER IFC-2015 EDITION SBUS FIRE ALARM SBUS CIRCUT 1-4/C #16 AWG FPLR CONDUIT OR OPEN RACEWAY - - fT ° `- r INSTALLED PER NFPA 72-2013 EDITION NAC 2C NOTIFICATION CIRCUIT 1-2/C #14 AWG FPLR CONDUIT OR OPEN RACEWAY 33:m002 FIRE SUPPRESSION/ELEC ROOM LOW TEMP SENSOR & MONITOR MODULE ann J INSTALLED PER NFPA 70-2017 EDITION 33:m003 FIRE SUPPRESSION/ELEC ROOM TAMPER SWITCH MODULE-BACKFLOW Device&Wring Notes: All device wiring to be Class B configuration and not to exceed 33:m004 FIRE SUPPRESSION/ELEC ROOM TAMPER SWITCH MODULE-BACKFLOW hOand Hosoh- maximum distances per wire gauge(16 AWG=4900 Ft), SYSTEM OUTPUTS All audible notification devices to be set to a three pulse temporal DEVICE LEGEND 33:m005 FIRE SUPPRESSION/ELEC ROOM TAMPER SWITCH MODULE-DRY SYSTEM pattern. ° I CONTROL UNIT NOTIF- FIRE SAFETY All audible and visual notification devices serving the same area SYMBOL TYPE MANUFACTURER MODEL CANDELA MOUNTING COUNT 33:m006 FIRE SUPPRESSION/ELEC ROOM LOW AIR SENSOR MODULE-DRY SYSTEM 7, f i F) r g 5 , rh are to be synchronized. OF WORK FACP FIRE ALARM CONTROL PANEL FARENHYT IFP-3O0 72" AFF 1 33:m007 FIRE SUPPRESSION/EELC ROOM PRESSURE SWITCH MODULE-DRY SYSTEM ANNUNCIATION (CATION CONTROL C 5496 AUXILLARY POWER SUPPLY FARENHYT 5496 72" AFF 2 33:m008 FIRE SUPPRESSION/ELEC ROOM TAMPER SWITCH MODUEL-WET SYSTEM COMMERCIAL ALARM AND DETECTION WILL INSTALL A NEW Q PULL STATION FARENHYT IDP-PULL-SA 48" AFF 1 FIRE ALARM SYSTEM TO PROVIDE SPRINKLER MONITORING, 33:m009 FIRE SUPPRESSION/ELEC ROOM WATERFLOW SWITCH MODULE-WET SYSTEM O C• MANUAL ALARM AND SITE EVACUATION,THIS SYSTEM WILL 02 SMOKE DETECTOR FARENHYT IDP-PHOTO CEILING 5 , O(� UTILIZE tNIRELESS RADIO TRANSMISSION FOR REMOTE 0 HEAT DETECTOR SYSTEM SENSOR 5623 CEIUNG 1 33:m010 ELEVATOR MECH ROOM ELEVATOR SHUNT TRIP MONITOR MODULE : t +O +1� EMERGENCY DISPATCH OF FIRE ALARM EMERGENCIES. O ,0 Co .O THIS WILL BE ACCOMPLISHED THROUGH THE USE OF pi LOW FREQUENCY SOUNDER SYSTEM SENSOR HW-LF 82" AFF 37 33:m011 ELEVATOR MECH ROOM ELEVATOR PRIMARY RECALL RELAY MODULE 'N • ' s ED STROBE SYSTEM SENSOR SWL SHOWN PER DEVICE 82" AFF 5 \Ct t 0 • -C v`O t TWO WAY RADIO SUBSCRIBER UNIT TRANSMITTING ON WEATHERPROOF HORNSTROBE SYSTEM SENSOR P2WK SHOWN PER DEVICE 82" AFF 1 33:m012 ELEVATOR MECH ROOM ELEVATOR SECONDARY RECALL RELAY MODULE c a +�O ay •4 ,c•• ? C O FREQUENCY 465.9875 MHZ LICENSED TO ALARM CENTER OF EK � �. +�, .�� •� • t LACEY WITH THE ECG.THIS UNIT WILL COMMUNICATE TO O' LA LOW FREQUENCY SOUNDER/STROBE SYSTEM SENSOR P2WH-LF SHOWN PER DEVICE 82" AFF 6 33:m013 ELEVATOR MECH ROOM ELEVATOR FLASHING HAT RELAY MODULE John E1I1 d�a �I �Om r� a �� r�V� e� Qj•�� �00 CENTRAL STATION THROUGH A MINIMUM OF TUVO GOOD WATRERFLOW SWITCH MODULE FARENHYT IDP-MONITOR RISER 1 33:s001 FIRE SUPPRESSION/ELEC ROOM SMOKE DETECTOR a .'C +� \b O • 0 PATHS WITH A NETCON OF 5 OR LESS.THESE PATHS CAN E �e • • • \ ' O %• J Ci) 0�\ OV BE DOCUMENTED UPON REQUEST OR VERIFIED DURING J JUNCTION BOX 16 TDETECTOR C J O G AES AES RADIO AES AES-7788F 72" AFF 1 33:s002 ELEVATOR MECH ROOM SMOKE •�.� O�Gj� • (an_ FINAL INSPECTION. Q � VICINITY MAP c 2 : e •Q CO „,o co J aJ 33:s003 1ST FLOOR - ELEVATOR LOBBY SMOKE DETECTOR g . c% 4 O O v0 OC C p a� �T TAMPER SWITCH MODULE FARENHYT IDP-MONITOR RISER 4 yak SCALE: NTS . 'may oc k ;, J0 ., .S , �` �M ADDRESSABLE MONITOR MODULE FARENHYT IDP—MONITOR RISER 1 33:s004 2ND FLOOR — ELEVATOR LOBBY SMOKE DETECTOR F QJ 4 Vm •0 �m ,� �O ® ADDRESSABLE RELAY MODULE FARENHYT IDP—RELAY RISER 3 33:s005 3RD FLOOR - ELEVATOR LOBBY SMOKE DETECTOR QN,��Gj j�4% f?1*< t�•-ed O �� Q<��O E LOW TEMP SWITCH POTTER RTS-0 1 CO PRESSURE SWITCH MODULE FARENHYT DP-ONITOR RISER 1 O�Q�O�0 O�QJ b Zc--OCOOO 0 r3 LOW AIR PRESSURE SWITCH MODULE FARENHYT IDP-MONITOR RISER 1 O€tea of Ja of Ja �O ,�����&co �J _rD' - C.) Q.. U Q- G� /�c�r/�U� aCif... }..��}./��� \�[/�) ,ACT '` ,ACT ,`J '�, +`J '`. S �0 mac/ ' c/ CJ �srcr�TT�re0itC/& 474- SYSTEM INPUTS A B CID E F G H I . JKLMN rpp r fi Mg 4) 1 Manual Fire Alarm Station - FACP 4 • • • •i• • 1a 2 Heat Detectors • 01111111111.11 i• • • 2 AES RADIO 7788 3 Smoke Detector- Elevator Mech. Rm. • •1• ••I• •• 3 MERGIL 4 Smoke Detectors - First Floor •D��� •1• •;• • 4 LOCATED BY FACP 5 Smoke Detectors - Floors 2-3 •:• • • • • • 5 & DETECTION INC. i 6 Waterflow - Electrical Rm./Fire Supp. Rm. •I• •I• • • • 6 17199 BENNETT ROAD N J, o 0000 7 Tampers - Electrical Rm./Fire Supp. Rm. • • , •_ 7 MT VERNON, WA98273 in RESET ' 5, 3 o „ 8 Pressure Switch - Dry System Riser • • •1• • • • 8 LICENCE #CO 848-1 48LO SWITCH -- = =C::'.7 PHONE: (360) 848-1533 a 3 ii: 9 Fire Alarm AC Power Failure • • • 9 U Accessory BProgmmmer N rJ 10 Fire Alarm System Low Battery • • • • 10 Co Port 11 Open Circuit • • • 11 C ��%%■ J4,Antenna Cutmrouble 12 Ground Fault • • • 12 .� fe� ' ,, � „-�.-.,. Ca / Output 13 Notification Appliance Circuit Short • • • 13 SIGNATURE jay,Fail Secure /%� ■ 70671NTELLITAP-II MODULE Form C ContactRaiting:24 dc,la ABCDEFGHIJKLMN N.L, Resistive KERN I E STEBAR % FIRE ALARM MATRIX OF OPERATIONS NAME - - ••--- ________c:: C E R T GN RD GY BN ii Ri C -y-- V # G 3 0000000000 3 CERTIFICATION NO. L/ 1 /21 24 G Z2 Z3 G 24 25 G Z6 Z7 G Z8 EXPIRATION DATE ITi A 16.5VAC +BAT- 5496: m02 5496: m03 LOCATED IN ELECTRICAL ROOM LOCATED IN ELECTRICAL ROOM No. DATE REASON FOR REVISION IFP-300 FACP NOTE: ALL 7788 - LOCATED IN ELECTRICAL ROOM resistors 2.2k Ohm ® ® U 4 .11/ l<I>I - o m i&I>I \ 7 2 16.5VAC,40VA ' I�' u ' ' J_. - E "I '�";:_�, III - .,_P .Jo Transformer .ICI>� I _ _ ! se 41 OO 12V 7AH a =`� BATTERY • 111011-11) \N--___ - 1 1—I) mai*--fii [ 0 ��� m ' . NAC4 40 R SER DIAGRAM 0 C ) , ° 00 1 : L y NAC3 tFI4 a��drl EN: 00 il FARE ALARM MATRIX FA-1 m ° Ismael ® VICINITY MAP 0 21 0 I $ NAC 2 F F F LF e t 7 F F 02 02 DEVICE LEGEND/CABLE CODES ® ® _ FLOOR PLAN - MAIN LEVEL FA-2 C ijc_ u° aLi _ . y NAC 1 mgmXmEmnm m mR: _ FLOOR PLAN 2ND LEVEL ® °� o LI I FIREAt.ARM RELAY FLOOR PLAN - 3RD LEVEL FA-3 ^ m 0 o o n (�* II BATTERY CALCULATIONS 1� o P g RELAYS ❑ ❑ 1 1=0 1 1 I I 1 1 I n g SUPERVISORY ALARM RELAY _ _ _ _ _ ;, o 0c ®® C C ® ®® MH �' QUANTUM CONSTRUCTION ON IL-iI �o ° I I ° I „ x,�l 1 I .°.!,° I - " , I • ,4' ' ; • 1 276 1 QUANTUM LANE Co 1 , o _ Di i TROUBLE RELAY ANACORTES, WA 98221 Z < ,0 ��������I = 0 °' ft!111 ►m ►mET NAC 8 UNUSED NAC 12��� ® ,.,.,., La PHONE LINES ® ® m NAC 7 NAC 11 PROJECT MANAGER: 360 BaldwIn n r ;; ►111 ►m ►m ►m ►m ►m ►m NAC 6 NAC 10 0656 CDEMACELL: --- IL:Josh17@civantumcl.com ° I� �a ► ® i IF IF �® ►® IF IF ►m ►m NAC 5 NAC 9 • a 9 I 0 AUTHORITIES HAVING JURISDICTION: ° 0 : ,0. : ° ❑ ® of CITY OF ANACORTES ®I . ° Al ',` 89. 0 a En = e and LEI B u I e u I o - © a CITY OF ANACORTES ANACORTES FAMILY HOUSING-PHASE II hia -L IFA ;;� ,I -gar - - FIRE MARSHAL: I O I 7th . I ANACORTES, WA 9822 I TWO 12V-7AH APPROVED PLANS BATTERIES PERMIT#: i?2_ b l g — DO 12. _ SLC LOOP 1 DEVICES: ADDRESS: /O/ 6 27, S = (01 :s001 159, 01:m001-159) APPROVED BY: I `"�----- r © N 0 T rgi iI SEE POINT LISTING _ lili FA-1 SUBJECT TO FIELONSPECTION. APPROVED PLANS JAN 041 ,2019 , ,�,t/ FIRE ALARM RISER DETAIL SHALL NOT BE ALTERED WITHOUT AUTHORIZATION. DRAWN BY I I DATE /28/I g CHECKED BY 4 ,i SCALE: NTS t IF La CITY OF ANACORTES PAGE NUMBER JOB NUMBER I OF 18- 191 1 °� est £k t 2 NAC 3:.:._.. „ Elk r �� zo,,,� ` N.STAIR "r x t" z� NAc 'r li R:,, I' II . ' 1 7CD ; ` .. ;; ., � 00 #F1AYxB Ft ED 1 1.",', #1F- BATH v rT �-y t - Si ;* ... � 1A ADA p I DESIGNCRITERIA mp E' #1F- BED .... .-_' T za-.'ka, CLOSET at DESIGNED PER ( C-201DITICN B H J �. INSTALLED PER NFPA 72-2013 EDITION "' 05/\ EOL S110 ^0 ` �� INSTALLED PER NEPA 70-2017 EDITION 00 CLOSET-- Y p ° Pi F-I BED APT. r ems: w .,:, #1A-2 BED ADR APT, Device&blaring Notes: d eras ig 177 rf a CLOSET I All device wiring to be Class B configuration and not to exceed !!!:::::: g maximum distances per wire gauge(16 AWG=4900 Ft). e .. 1 \ HAM!, r eel r;__ /,/ #1A'" BED 2 All audible notification devices to be set to a three pulse temporal 40 ➢,..cf watraa .tea:'•. w.nw �. r Y € 0,— U 995R F[ `.: i' pattern. M.1%. •1/454%11 i (; All audible and visual notification devices serving the same area ° 0 j ?: are tobe synchronized. 1 EOL►tii � p= lartarar`r 4411 -.. �"I I ° SCOPE OF WORK : CLOSE€ CLOSET ° 11 „� �. ,_:.: COMMERCIAL ALARM AND DETECTION WILL INSTALL A NEW ,,.„a„.,.... a,,.. aa... ............°...,....,�.. „... ,a° ....,...11 FIRE ALARtu1 SYSTEM TO PROVIDE SPRINKLER MONITORING, a 1555, act , fiAANUAL ALARM AND SETS EVACUATION,THIS SYSTEM WILL z ' UTILIZE WIRELESS RADIO TRANSMISSION FOR REMOTE ,,, EMERGENCY DISPATCH OF FIRE ALARM EMERGENCIES. �' ' �� HALL v i, ;i€ THIS WILL BE ACCOMPLISHED THROUGH THE USE OF �' N d #16-BED 1 ;r„ TWO WAY RADIO SUBSCRIBER UNIT TRANSMITTING ON o - 111L-.. EOL 'QiSQR FREQUENCY 465.9875 MHZ LICENSED TO ALARM CENTER CT II LACEY WITH THE FCC, THIS UNIT WILL COMMUNICATE TO #1 E-ADA STUDIO ;; � CENTRAL STATION THROUGH A MINIMUM OF TWO GOOD #i B-2 BED APT. , PATHS WITH A NETCON OF 5 OR LESS.THESE PATHS CAN o-o-.a.,o-.—a',..,.:a � � .e",,.°.,? j I 313 Ri 1 BE DOCUMENTED UPON REQUEST OR VERIFIED DURING • a ,,� 07°; i 0,d,; I 2� FINAL INSPECTION. 1 #1E-ADA ;:1,4,.st::- 33.m009''{{ #f1D- BAT BATH 11 U F #16- BED 2 ©33:m0061 wer YSTEM i P Yyl i c r° �e„ (7\ $ e r ' 33:m007- ESE CY.OSI€ f.�.f75F'f u# R t it ir 8 , ., Y �.433 DRY SYSTEM ,° : 3µr,eM.ee, a,T -- t� � eM n „i �j33:m005 € CLOSET 1 , • © r, , m o� a - 33:m004 AC � € `€ $. „ KFLOw f:. r r-a� r oir © �, w.; m �33:m003 B cti msiimilis t9'33:m002 U 1 D- BED ' � � I � s°"A- mao2 FIRE �' .� ABA RESTROOM �r , 4 ,� a o 151 Se SUPPRESSION �S, 3.s0 ���wwwac z--nc_"'rwc 2.--a Po 9 #1 E3- BATH e M 3 0 »t16- 1 BED APT. a S. STAIR r i os.,.; ; 1 & rn i .... ,.0. . 1l 8 3 s001 ELE£TRICAL m NAC ROOM /RISER RRoom n; S _ - � � _ r -- � ,a.,a..- ., .a mm F..m, ., ��a a... .a, ,aa, m a (SEE RISER ROOM DETAIL) :'3v 1' , ��j�j VI COMMERCIAL }per($jam, F, CLOSET4rems i Y w. ,�w�.,w'rz #°rc'u,"+Yn .�-Ip u2"d .✓da° • •I . V°tln� Q / COM 8iCIAL tz, 551\ m c- BATH r^-^r' z.e ALARM ��'''1��}$$��� j�'{y� DETECTION {�1,�, �@�{j, ]$�, CC fi3 SQF G U .. ALARM & DETECTION NC, Q � a L' - 17199 BENNETT ROAD i, G 5 13:m001 r ( mll• "- �a�a.� ELEVATOR �� MT VERNON, WA 98273 LS sE 1C-1BEDAP . �� _ /��� ___ / MECH. Race 1 ' N O B 4019n� :�o D IL JA LICENCE#CaMMEA19a8Lo % �� rift FACP DETA PHONE 3s 8-1533 .v. n-w ' 4aP� 8 .� a RISER ROOM t °� ` , `"` pc./ 4( SCALE: NTS I CITY OF ANACORTES t F HRTO FACE 9"1c _o , --". LAUNDRY ROOM �l.► der;%ae ° ,. a ��`�� ©33a003 (-��33s0026zF #1c - BED i- "teqedw.msmum...L.. estries..........„., " vvi , 1 I / �, -LEVATOR. . _.- ROUTED TO `\0 R 33:m013 U ° . FLOOR ABOVE . " , _ - s`4' R 33:m012 IS SIGNATURE r; Y p. R 33:m011 BERNIE p R p - "• • 00 V1\NIIJ I\L _ ; 33m0i0 f I.STAIR UTILITY c NAME �� f r_ ., err �"�., ;. A- 1 I i F IiiP a� h.Ci3ED IFLOOR PLAN — MAIN LEVEL �a-�E #2a-BATH / ' NICET IV # 1 I C 93 — LCERTIFICATION NO. esso� L° _.._-_ _____ ___-_ ___. #2A-BATH at ist'ir �i► SCALE: 3/ 1 6" = 1 ' 4 / /I e J ev z H e ' 4/ I12I RELAY.BY OTHERS c `" SUPERVISING 20 AMP a a t EOL a ' & #2A-2 BED APT. tc" I/ I CLOSET C BED PT L m� EXPIRATION SHUNT TRIP BREAKER "r"�I i al._,..,..a.,...,,,_,;�, Ewa: �ytaA s., A 3 __ _ {fie! � fVkwr -°rr° , , ,,, .,a ExPiR, DATE 50 % s _spa FACP CLOSET E 441 b II P` NO. j DATE REASON FOR REVISION SYS-5623III R IDP-RELAY PRIMARY RECALL R IDP-RELAY SECONDARY RECALLI s.,_..c� #2A- BED 2 . R - IDP-RELAY FLASHING HAT s 'tac 0 y c M IDP-MONITOR SHUNT TRIP SUPERVISION <,,, EO CLOSE a T 1 __,...,-,.. ._ ij> ADDRESSABLE ELEVATOR RECALLS, - I/ 4,2 11 (SCHEMATIC DETAIL PER ELEVATOR LOCATION) 9 L CE u • ` HALL •pM. _ �,�' r� Acs �4 1c#26- B D3 a"i. RISER DIAGRAM FA-1 #2E-sruDIO FIRE ALARM MATRIX VICINITY MAP #28 PT. �� t -28Et}k _ a ' °��,rre� DEVICE LEGEND/CABLE CODES 1 FLOOR PLAN - MAIN LEVEL FA-2 ," f FLOOR PLAN - 2ND FLOOR \�#2E-BAny 1 a� FLOOR PLAN - 3RD FLOOR FA-3 0,05 x ik r U .N2F- BATH :.., .. F 2s-BEL 2 'VISOR' 1 e Cf BATTERY CALCULATIONS 1:4 -- --- — " .N*A1/2 ii :iii' m Jx. �' 7 _ ;IE QUANTUM CONSTRUCTION/ ' � �� ° 1276I QUANTUM LANE #2E- BE ,13 P°6 ` _, g� lo _p .p ANACORTES, WA 9822 I #2E- 1 BED APT. al .r 2R.pF€ G ¢ ae #2 _BATH ova .:. 6�" _ PROJECT MANAGER:Josh Baldwin {}�' -�' 7 _-- _ - PHONE: 360-293-0656 P CS""'QC.......MAC 6"/1.0 v S.STAID N!90 • le J CELL:--- ? EMAIL:Joshb@couantumci.com 1 € ,,, ,P.mma,,,,,,,,,,,,, ,, ;, ,, ,, ,,;�a,. ,aa<«....�,. ..,a,m.a,,,.a ,a,,,aA.;. -> .."_ . r ~`� " t p . AUTHORITIES HAVING JURISDICTION: / d '1,, ;- 7, — ---- .. ti #20- BATH CITY OF ANACORTES .a" 65 SO F: ° a Sze-1 BED kPT. q and LEI CITY OF ANACORTES ROUTED TO 1 :�% n ; Ago x, ° 77: -.° 7,° t / /FLOORABOVE r ANACORTES FAMILY HOUSING PFIASE II FIRE MARSHAL: ~-h1 CLOSET A APPROVED PUNS `N---� ,;� I ( , : �0 16 27th ST. :; o D oo,,ao.,;e PERMIT y1 /� #2D- 1 BED APT. a , - l ANACORTES, WA 9822I b - w D - Opiz $ .. sen I HR/Tp FACP 6 �QaRESS: J 0 / _ -7t S F^ 3 I / 33s004 CLOSETF HR TO FA P €I HRTO FACP A PPROVED #20-BED ELEVATOR cr � : or fi ROUTED FROM 41 E1 h as.Si r"'' #2C- BED IP NSPEEFiL?N. APPR FLOOR BELOW „‘..'2 ,a S'AALL NOT BEAL7ERED'WITHOUT A417,IIZAMIDN 'f ;,.., ,,,,,,, FA..2 isa .. DRAWN BY DATE CHECKED BY /4 ', FLOOR PLAN — 2ND FLOOR KSG 1 1/2a/ IS BS E PA2► SCALE: 3/ 16" = I ' 2 of 3 NUMBER JOBI NUMBER y ------------- "-Octal Pro,=ec�.Values: ,:...^.,, ^,:...,,.�....... .� Pros [Name: Anacodes FAM HSNG-Phase!I J Standby Hon! 24 -1i Faroe ihy[^ Series ° , :.:•rc.�",�, coenemeo - ;,IPk# ,113t 18-191 AlvaroMin r- 5 1 - I 23, Prep nd ByIIKS ,e ' Deratino Fecalr Lm 1.2 1 I I.H':;<;.,- IFI-3001ECS Calculations-IDP Dete:E2/3112018 1 Voltage Droll Warning ,Ve7Sipn04.16,38..... .,.;):.. ., ..-` RITERI rr s9€i.r r 0,_ - I { gg�.'ro�ESI qa'�_ ,;g,,g l Panel ID:FIFP-800/ECS DP Devices _ Model:IFP-300/ECS Fire Alarm Control Panel Max NAG Current S:9.Amps 'I DESIGNEE) PER IFC-2015 EDITION I -` Location:LELECTRICAL ROOM I Volts: 24 VDC Max panel Current 6.0 Amps INSTALLED PER NFPA 72-2013 EDITION - INSTALLED PER NFPA 70-2017 EDITION Current Draw Wire AWG Ohms Per Lenpth(41 Actual Volts© v I ,'' Part# _ Descrip11r7rs. . :. Ow 1000r lump e Standby Alarm &TypeFtnewv ay rn s 0t _ Device&Wiring Notes: G FP a Fire Arai rc Control Unit 1 1 0_'190 0 250 All device wiring to be Class B configuration and not to exceed • a-P ow Pha T,,P a Smoke detector € 0.0015 o 001 s_ maximum distances per wire gauge (16 AWG=4900 Ft). 'OP-Fire-CO Fire co detector o.0000 0.0000 All audible notification devices to be set to a three pulse temporal D4Hera Heat-HT,ROR Heat detector 0.0000 0.0000 pattern lOP-Beam,EearrrT Beam detector a0000 o.00ao _, - f-,/,! AC3 audible and visual notification devices serving the same area DNR Duct housing - 0.0000 0.0000 ;;;1 IDP Acclimate IDP Acclimate ( 0.0000 0.0000 i:? ,,= are to be synchronized. lOP-Phatnu 4y Photo W 0.0000 0.0000 °:y, 1� IDP-Photo-FV W Photo-R-W ° 0.0000 0.0000 -' �`�,, IDP-Photo-T-W Photo-T-W 0.0000 0.0000 \ / COMMERCIAL ALARM AND DETECTION WILL INSTALL A NEW H3P-Heat3N Heat-W 0 0000 0.0000 FIRE ALARM SYSTEM TO PROVIDE SPRINKLER MONITORING, I r _ IL1P-treat-ROR-W+ ° Heat-RCR-W 0.0000 0.0000,ESE ET � MANUAL ALARM AND SITE E EVACUATION.THIS SYSTEM WILL DP-Heat W Heat-HT-W 0.0000 0.0000 e UTILIZE WIRELESS RADIO TRANSMISSION FOR REMOTE OP-Contr.)!t Control 0.0000 0.0000 is, IDP-Control-6 =Control-6 0.0000 0.0000 EMERGENCY DISPATCH OF FIRE ALARM EMERGENCIES. DP Mon to=,M' morr Monitor,Minimon 40 0 0038 0.0038 e NEE/° N THIS WILL BE ACCOMPLISHED THROUGH THE USE OF DP-Monitor-2 - Monitor-2 0.0000 0.0000 TWO-WAY RADIO SUBSCRIBER UNIT TRANSMI I I ING ON i ' DP-Monitor-10 Monitor-10 0.0000 0.0000 i° IDP-Pull-SA,PulTDA Pull-SA,Pull-DA t 0.0004 0.0004 FREQUENCY 465.3876 MHZ LICENSED TO ALARM CENTER CP T WILL . .--..-..-.ar ,..-_.- .-.,.,,,,.- .-r-:_1_,._, . �II ' , _ __ r°. I4GV..,..„ , ^ .,, ° .... ,..._ @P-Retay . Relay 3. 0.0008 0.0008 NICATE TO „ ,.,.r,,,,�,�.°, :..-.. _.. �: ,°„^..:°.,�. .,,:°.,._. _... .:aa� r, -... .. -,t....,M, ,. .. 8a:6, iz,,�uv°aa&ie ,SGhS �al _ a ,. CENTRAL STATION THROUGH AI MINIMUM OF TWO GOOD e .. . ,°.°°,°° d<a,tke0"L9aS�m, ----....._....... �%t" . ?? .. ,._.._-.----..-..-ice = iDP R..iaY6 RelaY-6 .° 00000 00000 .' IDP-RelayMon-2 RelayMon-2 0.0000 0.0000 '.° PATHS WITH A NETCON OF 5 OR LESS.THESE PATHS CAN I ,i' 1 ^,a re." ce--=w -tic 2fIDP-Zone Zone 00000 o.0000 :: BE DOCUMENTED UPON REQUEST OR VERIFIED DURING N" 'oTAtR UTILITY/MECH FINAL INSPECTION, i-§ *; EC 1 IDP-Zonei6 Zone-6 0.0000 0.0000 • I a,°' - - ' _ '� .''- ter,-BED lOP-iso ilsalatar Madule)�° iso(Isolator Module) °° 0.0000 0.0000 ° ' ' /� pr` :1 4 li' 2:- c� < "a/'I IDP-ISO-li ISO-6 " 0.0000 0.0000 ✓PE #3G-BED HC- BATH r." {1 ° 622461 isolator Base 2 0.0000 0,0000 ` s' ""`�^ rT° .vstr "' r t p. #3A sr1EATH '' 6200$ Sounder Base ,- - 0 0000 0.0000 ^"irm„, - 's" £ i`i I}},x EOL rs 6200SR Sounder Base 0.0000 0.0000 # , < `v u ,,,a,,,,, r45,4. ,. y„1%� z ,3,' sr84a. ,, s :,y- =;i ...:.,.,,..u. �.,.;.,,,:,.; I 6240S-LF Sounder Base LF ' 0.0000 0.0000 - .« .3„........ s y r-'""" t\r- ,^w s'� E` ( ''''1; '- 9200SR-L.P Sounder Base LF 0.0000 0.0000 ,a{r.; ter ;, #'3A-2 BED APT, 3224R6 Relay Base 0.0000 0.0000 °.q0a„- -). t i BE Y 4'9 Ss r TY FOL a : CLGSc. RTS151 Magnetic Remote Test 0.000 0.0000 11 ° �Ur-�� Ti,F 3a>' Ei 'dT-" P . , "�; 791 - - _°° �- RT515-IKE f Key Activated Test 0.000 0.0000 ""�.., "F «a s4F F ; �. , °ram 2:,, `� #3G 1 BED APT, )' r %% re 'a'>'t`" .....*' e a 685 SLC Expander 0000 0.000 -- ° r a, .mot CFF-- -E. --,CLOSET t-trof -+ 1 .,...,. ___ - t =^.., is RA-2000 ° LCD Remote Annunc ° 0000 0.000 - ( _ o RA-1000 LCD Remote Annunc 0.000 0 000 ,;:, _ .: ..a 2,- ) 1 .,9 (il ! RA-7ifo LCD Remote Annunc 0.000 OA00 _ t \4 T-e4 �`t�2 #3A-HED 2 q rixg 4,, ( 5824 SerialfParaltal Module 0.000 0.000 y 5496 Power Expander 1 0.010 0.010 ., . ,. , ( RP<41001) Power Expander 0.000 0.000 irE\ :0 EOL CLOSET bi v ' 5865.4 LED Annunciator(4G) 0 .000 , . MI ' ,.`^.«„^'^,,,""„°, ";,,,.,"'m'"°"°°,°^"" -E L s, 5865-3 LED Annunciator 3G 00 000 0 �it^ of"°m°"°°.a=„ ,�-° .,.�,.«,m-.,,w�, ,^,,,a. .« �,m�,�..,,,«��,ge�,��„a=:,�„a«,� �,:, er:-rim , .,T �,. _- - _ 5880 LED Driver Module I . (i r' 0„ t �' f tt co y �. .'i. ° 5883 Relay Module 0.000 0.000 ,,, II I OOP E CIA �a s ELL MOb Communicator D.000 0000 `i i -- °m-- ^ °m° _��°� - ' i € > r E C SK NIC Network Interface Card 0.000 0.000 DETECTION g'.-g g�� \c 7 9'� $ E "Ate' / I ALARM �.T� 1 EC i I I�i INC. -"' AC r' HALL ec' '-" a :11 SK-i ML Fiber Module 0 000 0.000 i &` ? }r #3B-BED 1 Sh ILL Fiber Module 0.000 0.000 _ ,DP W6�1 wireless Gateway 0,000 0.000 17199 BENNETT ROAD ' #3F- STUDIO EC -Nvcna Voice contra 0.000 0.000 MT VERNON, WA 98273 n LICENCE#COMMEA1948L0 0ECSE3W24 °Zone Expander 0.000 0.000 PHONE: 60 848-1533 # B-2BEDAPi. 0 3 ° ,,,;,, . �.- s FO'"'"''4c ""6 RR? Remote Paging Unit OA00 0.000 ° ` 0.000 0.000 i TVs t `s """ _ ECS-LOC Local Operating Console """^ ey...xe -'" _. ._, '"�"^:".;`�a `�, SO Watt internal Amp 25 ..,.^%tT ` ° w�++�' c �T l E4:S-IPtTSrW 0.000 0.000 m 2 °" f= itivio„.............L.0....t erseale.........a...... t t volts r10 o o tl '` SO Watt Internal Am 70 ° = 3 _° 7 _ t^ ECS-INTSCW R ` 0.000 0.000 ° #9E-Einri t a 11 BAT s =a p volts e i #SF BATH i 1 a #36 BED2 1=L°°^tEtm° v9 .._ _ _. .. ..2,„„t � + Ecssovr so Watt Amplifier 0.000 0.000 SIGNATURE CLOSET CLOSET ( 3 0 _Al _ ECS-125W 125 Watt Amplifier 0.000 0.000 t , i '1, d - ECS DUAL„OW 501100 Watt Amp 0.000 0.000 r - pBERNIE STEBAR .s -„�.. KERN _° _ _,„„ a ._._. ill _ S sOVNE#f3 50 Watt Backup Amplifier 0.000 0.000 �'� e, _ - ° ° ) , NAG#1 Notification Appl Circuit 1 0.000 0.575 - =So r_. 2.e ' to 0.68 18.73 8 19% �,, ose �^ NAME >-.-. -m .�»«-•_-•-----_-�-- aay Was 1 / °^10 "'"""^ g:„� _ NAC7#2 Notification Appl Circuit 0.000 1.298 #14 Solid 2.52 93 0.47 19.79 2 98% /'''' / ./,�. j'` (� I �,. 1 ,, � tiR To � ( 1 ET I V 7Y b� ✓ s J - z x. NAC#3 Notification Appl Circuit 0.000 1.097 #14So Solid 2.52 96 ti 4$ 19.87 2.60%� P3F' BED r„ • � 3 1 � y NAC#4 Notification A (Circuit 0.000 0.100 #14 Solid ZS2 3C 0,15 2Q-=38 0.07% s"" :_' P PO : . ` I zI #3C BATH ° PACP Total Standby Current(Amps) ozos 3.336 ToYalAlarm current(Amps) CERTIFICATION NO. ,1; ° > s°. r ' •l .._ u '2t Standhy Trills to Moors 24 4.083 Ataan T#ne In tvTm€rtes 7 60 (5 Mcs; C { ^�-QC .rAcr #3E-1 BED APT- S STAIR #3B BATH �k4. To al Standby AyRequired 4.953 0.278 Total Alarm AHRequired 1.4 1 �� ���n �, .M_m._ 4/ I /2 I 0 t =e i" ¢=S&:il °y :."©: . _ ; Muto€'rpiv By The Darating Factor 9 20 -. ... i2, M B 828 ConfigureGrowts `� .°m.;,,,...,.as �.. ., -., rrPrflum Battery p Quin Required L. -....-._ Zr qt HPage EXPIRATION DATE -- BATTERIES USED R ur 58, : (2) 12v-7AH R \ NO. DATE REASON FOR REVISION 'I 1, . - L: #3D- BATH q -GlobalReject Values: N _ #3C- 1 BED APT- t '' SIZE T w :i ,"8' Project Name: Anacrotes FAM HSNG-Phase II Standby Hours s I r) y KNIT HT Project ID: 1 a-191 1 AMrre Mins « �"- - - °� ;' Prepared By KS De aline Factor 1 o ...._,..z_,..,� - 5496 Power Expander Calculations Date. ",2;31I2018 [oboes[,•op a amc ' 8 - Version 0^.24,09 rn-ezho % - #3D-1 BED APT. i... ... ---- 5 �c w0.1 '� �-� a«;4r 0 HR T FACT 33:5005 CLCSE t s°= I T° Panel la L5496: ROOfti Model: 5496 DPower Expander f,iax 3A C`,=•Ent 3 0 at,cs i C HR TO PP HRTO MCP a ( .� .`2�,m°, Location[ELECTRICAL #3D- EEC ;P - EOL ELEVATOR PIO 4- s : ,.;w�` 1 , r #3C' BED ,';;'2 « O.g.� „r,,r,`";."�;.,. . S rr• ,. :ex;r= Current Draw Wire AWG Ohms Per Length CIE Actual Voles a ' �n.,; „rc= ROUTED FROM h, pc' i Part,YF Description Qty _t Standby Alarm &Type 1QaoF o sway era o RISER DIAGRAM FAA FLOOR BELOW BE x^ �c� Nrca 5496 5496 Pwr Module 1 0.040 0.160 ,, ,w --_ _-,. .___ a e .,:,! N.AC#s Notificationwr Modpl Circuit 0.000 321 #14 Solid 2s2 90 FIRE ALARM MATRIX , ^,. w 'x;aea.u: egret ta`,Lw ` _--- NAC#6 Notification Appl Circuit 0.000 1.224 #14 Solid 2.52 'C 05 I 1E72 333 VICINITY MAP -- NAC#7 Notification Appl Circuit 0.000 1.321 #14 Solid 2.52 2C 1 0 ' -� I 6.53% DEVICE LEGEND/CABLE CODES NAC#8 Notification Appl Circuit 0 000 1.224 #14 Solid 2,52 __ 0.60- 19.6E I 3.63% FLOOR PLAN - MAIN LEVEL FA-2 Total Standby Current(Amps) 0 040 5.250 Total Alarm Current(Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes^so (5 Mins) FLOOR PLAN - 2ND FLOOR i kt FLOOR PLAN - 3RD FLOOR _Total Standby AH Required 0.960 0.438 Total Alarm AHRequired FLOOR PLAN - 3RD FLOOR FA-3 'AV SCALE: 3/1 G" = I I Total Combined AH Required 1.40 Command Shortcuts BATTERY CALCULATIONS Multiply By The Derattng Factor 1.20 - - . . - Minimum BatteryAmpfiours Required 468 Configure Circuits Print Page .. BATTERIES USED : (2) 12v-7AH 454 o 1t_�a QUANTUM CONSTRUCTION 1 276I QUANTUM LANE ANACORTES, WA 9822 I 63ob21 Proled'Values:e°° r SILENT1--- PROJECT MANAGER: Josh Baldwin Project Namo: Anacortes Fi.A1 HSNG-Prase I' Standby Ha.,rs : �.z KNIGHT ProjectiDt 18-191 Alarm M:ns: PHONE: 360-293-0656 _ Prepared By:IKS Derating'Factor - _ CELL: --- t m 5496 Power Expander Calculations - Date: 12'31'21)15 Voltageoto;.'Warnng EMAIL:josh Gjuantumcl.com Version 02.24.09 - rrr�hcS -- • '- tITY OF ANACORTES � AUTHORITIES HAVING JURISDICTION: Panel lot 15496:m03 j Model: 5496 Power Expander Max NAC Curent 3 0 Amos FIRE MARSHAL: Location:-ELECTRICAL ROOM Volts: 24VDC Max Panel Cement: 60Amps CITY OF ANACORTES APPROVED PLANS ;tom -° Current Draw WireAWG Ohms Per Length(ft; Actual Volts and LEI _ ttt� Il V L ! Part# Description t-'tY °,D.nP PERMIT#: 1� L-- `.) o I CI - 0Ci 12 - s0.040 Alarm &Type 00o F'_ one way ohms EDT 6 . . . 5496 -5496 Pwr Module 1 l 0.040 0.160 I NAC#9.•. Notification Appl Circuit 0.000 1.880 #14 Solid 2.52 _ b53 '9.4^ 488% ANACORTES FAMILY HOUSING-PHASE II ADDRESS: 0 - 2 - ' . . -1-• , , RAC#10diii Notification Appl Circuit 0.000 1.880 #14 Solid 2.52 _ 0.58 '9-3` 5 34% FA NAC#11 ^ Notification Appl Circuit 0.000 1.880 #14 Solid 2.52 0,63 '(4.22 5 81% I 0 I G 27th ST. APPROVED BY:- r -_ i NAC#12 ,UNUSED 0.000 0.000 #12 Sotd 1.59 0.00 , 20.40 0.00% ANACORTES, WA 98221 SUBJECT TO ME SPECTION. APPROVEDPLANS _ ThitI1SS(andhy Current(Amps) 0.040 5.800 Total Alarm Current(Amps) SHALL NOT BE ALTERED-WITHOUT AUTHORIZATION- Standby Time In Hours 24 0.083 Alarm Trine in Minutes 160 (5 Mins) .A -- -Total Standby AH Required 0.960 , 0.483 Total Alarm AH Required Total Combined AH Required 1.44 Command Shortcuts �yr�7 y7[11 ; - MuttiptySyThe Denting Factor 1 20 ' 1� S., Minimum Battery AnrpHuurs Required[ 1.73 Configure Circuits Print Page , . . a 1 JAN 111 . FA_3 . . 3ATTERIE.S USED : (2) 12v-7A11 043 4019 "1 DRAWN BY DATE CHECKED BY III i BATTERY CALCULATIONS CI7YOFANACORTES KS I I/28/18 BS PAGE NUMBER JOB NUMBER 3of3 I8- I91