BLD-2014-0499 - FIRE ALARM
Pencil is awl I nspe - BLD-2014-0499 - 2014 014417-001 ..arla. E. 11/07,12014 01:';9FM . City of Anacortes 10,1fi�olcil # fiC : _ IIC26419 LLC r • 904 6th Street ELD-2C tad-64 e I It Off+/ U,i t P.O.Box 547 Payment , 68.44fsil date: 11/05/2014 +p'` Anacortes, WA 98221-0547 Trans.ac ion Hri"ofmt: 68.44 (360) 293-1901 CHECK 0 XA�r, date: 05/03/2016 Job Address: 1300 O AVE Permit Type: Fire Alarm Permit ANACORTES WA 98221-2187 Project: APN: P55246 Remarks: Wireless Fire Alarm Communicators for AES-Intellinet for existing fire alarm at Chandler's Square. Owner: ANACORTES SENIOR HOUSING LLC Contractor: COMMERCIAL ALARM &DETECTION Address: 201 NE PARK PLAZA DR Address: 17199 BENNETT RD 105 VANCOUVER WA 98684 MOUNT VERNON WA 98273-9789 Phone: Phone: (360) 848-9093 License#: COMMEAD961 LS General Information: Fees: Building Valuation 980 Building Permit Fee 38.75 Plan Review Fee 25.19 State Building Code Fee 4.50 Total Calculated: 68.44 Deposits/Receipts: 0.00 Total Due: 68.44 THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. 0;ems,„ SIGNATURE OF OWNER OR AUTHORIZED AGENT ISSUED BY Fire Sprinkler/Alarm Permit Application City of Anacortes Building Department 904 6th Street— Anacortes, Washington 111111 } Phone: (360) 293-1901 Fax: (360) 293-1938 t _ p 'J r Ira 'Y r, � � NOV 0 4 201� 1t/11 ;, , Site Address: 1300 0 Ave Parcel No.: P55246 Lot: Block: Addition: Owner Owners Name:ANACORTES SENIOR HOUSING LLC Phone No.: Address: 201 NE PARK PLAZA DR STE 105 VANCOUVER State:_W Zip: A 98684 Tenant Tenant's Name:Chandler's Square Phone No.: Contractor Information Contractor:Commercial Alarm and Detection Phone No.:360-848-1533 Mailing Address: 17199 Bennett Road Mt. Vernon State:WA Zip:98273 State Sprinkler Certificate Level and License No.:COMMEAD961 LS Exp. Date: General Information Please Check: Fire Alarm ❑✓ Fire Sprinkler ❑ Modify Existing System ❑ Install New System ❑ Underground Fire Line ❑ Value of Project (labor and materials) $980 Required Submittals Three(3):Scaled construction drawings showing the following elements along with their dimensions 1. Floor plan indicating the location of devices and appliance, end of the line devices, conduit wire runs, conduit size and number and size of devices. The zone indication shall be placed adjacent to the appropriate end of the line device. 2. Interior,exterior and underground fire alarm/sprinkler components 3. Transition from exterior to interior. 4. Manual fire alarms and strobes(including installation height) 5. Fire alarm control panel location, riser locations and control valves 6. Door hold-open device 7. Heat and smoke detectors (identify type)duct detectors 8. System Calculations and manufacturers information on system components 9. Fire Sprinkler tamper 10. Water flow and control valves 11. Site Plan (Show FDC, PIV locations) Signature: Q Digitally signed by Josh Harrold Date:2014.11.03 14:11:31-08 00' Date: 11/3/2014 Applicant or Owner Updated November 4, 2009 1Ls - 2fic - Oci q 9 "A 0 I prnrilir ES ►�S ,1,_ aes-corp.com #SECURITY . CORPORATION '1,7`O1'AFION NOV 0 4 2014 i ` v is , ■ ie Wireless Fire Alarm Communicators_Tor AEcrritelltNet------ FEATURES Advanced Wireless Alarm Monitoring • UL Listed commercial fire As expensive dedicated landlines, required for alarm applications. • Meets NFPA-72 requirements UL864 compliance, disappear and the future • Direct reporting to AES of GSM for alarm transmission becomes receiver across AES-IntelliNet increasingly uncertain,the AES-IntelliNet mesh mesh radio network radio network continues to offer unmatched • Each subscriber acts as transmitter/receiver/repeater reliability and speed in delivering wireless • Simple and fast activation alarm signals to a central station without on network )t. Oa lYc ,i: any third-party fees or reliance on networks On board status LEDs for - ,I.,y =ri easy setup 1 eq..,° operated by companies outside the alarm • 8 programmable zone • F' ir,;�p industry. The 7788F/7744F Series Subscribers inputs-7788F Ptlii""" " provide the wireless communications link • 4 programmable zone inputs and 4 reverse polarity '3, between the fire alarm panel and the central inputs-7744F station receiver. Ideal for most commercial • Easy programming via AES fire alarm applications, each 7788F/7744F handheld programmer or PC • Rugged metal housing ideal i Series Subscriber is housed in a full-sized, for any commercial fire red, locked steel cabinet and supports a alarm application range of alarm panel inputs, including EOL • Narrowband compliant fire, EOL supervised, and direct voltage from the panel (non-fire applications). MODELS 7788F/7744F-ULP WITH AES-INTELLIPRO FIRE ALSO INCLUDES AES Subscribers offer fully-supervised operation that includes monitoring of • AES-IntelliPro Fire transmits operating power(both primary AC and battery back-up) and the connection to full alarm data from virtually the mesh radio network. Each subscriber"checks-in"with the AES central station any fire alarm panel digital receiver at least once every 24 hours.The supervision check-in time can be set to communicator • Alarm format support for as often as needed for the application, as appropriate for the network. Because Contact ID, Pulse, as well as the central station operates the wireless network, there is no additional cost for air Bosch Modem Ile and time to transmit supervisory signals. Modem Ilia • Easy installation in AES subscriber • Operates in applications with or without ahone line C ® US Et.,,„_ C 0 [7;1j _ „,,,,,,, het - LISTED NFPA® • HOW TO ORDER ata Ropoofrom AlarmPanel = x Models 7788E-ULP and 7744F-ULP come equipped with an IntelliPro-Fire Full 7744E 4 Zone Fire Alarm Data Module (AES-7794) which enables reporting of full alarm data captured Subscriber with 4 reverse polarity inputs from the alarm panel's digital communicator. IntelliPro-Fire supports most alarm 7744F=ULF 7744E Fire Alarm communication formats including Contact ID, Pulse, as well as Bosch Modem Ile and Subscriber with AES-IntelliPro Modem I11a2 (when converted to Contact ID format). Fire full data module • 7788F 8 Zone Fire Alarm Subscriber ^ ,,;.�, - 7 Fn = r.: - �� '�.!il. s:l_„ ] � �- -y _il�;. _��- '.z1a''�_� 1�s's /����NJ43�:1 f ! L/'-:; ��i' u�is� <., .1L��C��-�Ci��i�,?��=i( 7788F-ULP 7788F Fire Alarm Dimensions Reset' Button Subscriber with AES-IntelliPro 13,25"H x 8.5"W x 4.3"D Fire full data module Located on main circuit board. (34cm H x 21.5cm W x 11cm D) p crating Temperature,. r, `:.i ° a t ._: Weight0° to 50° C (32° to 122°F) 7K� d�� Subscriber Handheld e Approx. 7 pounds (3.2 kilograms), excludes battery Storage Tempe rat u'�' Programmer ° -10° to 60° C (14° to 140°F) Radio Frequency 774 AES-IntelliPro Fire Full Data • Standard Frequency Range: 450-470MHz G epa ive Humidity Module (others available in 400-512MHz range) ° 0 to 85% RFIC, Non Condensing 1640 Plug-in Transformer: 0 Output Power - 2 Watts 16.5VAC 4OVA A • Included 2.5 db tamper resistant antenna Packaged with 7744F.fUL P and •_;; 8 F,-,UL J , S �.:o r •.a i 4. mounts on enclosure o`t ' ` ' `" o Multiple remote antenna options available hliputiOu p its Connections Established in 1974, AES o RJ11 connection to AES subscriber for module Corporation empowers Power Dnpe9t data and power companies to grow profitable ° 16.5VAC, 40VA transformer (not included) (AES 0 RJ11 connector for Handheld Programmer/PC alarm monitoring businesses, 1640, ELK TRG1640, MG Electronics MGT1640 - programming UL Listed for use) 0 RJ31X Telco connections - T and R both in and out and government agencies to ����i���; �.�G���U'� via terminal strip and RJ45 enhance security anywhere Alarm Panel digital communicator T and R both • Will charge 12V battery up to 7.5 AH. Requires in the world. By providing in and out via terming strip and RJ45 the industry's only patented 12VDC 7.5 AH battery for UL 864 ° Trouble output: Form C relay detects if operator-owned and controlled Subscriber is off the network Alarm Sig€nai irnpi Nis (subscriber) private wireless mesh networks, • 7788F - 8 individually programmable zones AES ensures superior reliability, 0 7744F - 4 individually programmable zones and Aparm Formats low TCO and optimal RMR while 4 reverse polarity inputs 0 Support for Contact ID and Pulse formats as well reducing dependence on service as Modem Ile and Modem IIIa2 converted to CID provider infrastructures. tti Stairnd ands Size The company's flagship ° UL 864 Edition 9 - Standard for Control Units - 2.8 x 5.0 inches (7.1cm x 12.7cm) AES-IntelliNet systems are and Accessories for Fire Alarm Systems • UL 365 - Standard for Police Station Connected Power Requirements deployed in over a half million Burglary Alarm Units and Systems 0 12 VDC nominal - primary and backup power locations worldwide. ° UL 1681 - Standard for Central Station provided by the AES 7788F/7744F or other Burglary Alarm Units Subscriber Antenna Cut /Communication TroPubDe Ouitp t • Form C relay; fail secure; rated for 24 VDC 1A resistive For more information, go to www.aes-corp.com or call (800) 237-6387 or contact us at sates@aes-corp.co © Copyright 2014 AES Corporation I AES-IntelliNet is a registered trademark of AES Corporation INTELLIKNIGHT FIRE ALARM CONTROL PANEL SILEN InternKnight® Model 5820XL KNIG NOV U 4 2014 Addressable Fire Alarm Control System by Honeywell The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol • Built in support for 127 SD devices, expandable to 508 SD in-.Ik1:.10' devices using the SD protocol. • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator Model 5820XL • Central station reporting by point or by zone • Built-in synchronization for appliances from AMSECO®, • 6 amp power supply and maximum An Gentex®, Faraday, System Sensor, and Wheelock® addition capacity of 35lamp hoursire additional cabinet enclosure is required for • FlexputTM I/O circuits batteries in excess of 18 amp hours) • Supports Class B (Style 4) and Class A(Style 6) configuration • Programmable date setting for Daylight for SLC, SBUS, and Flexput circuits Saving Time • 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Installation • Built-in annunciator with 80-character LCD display The 5820XL can be surface or flush • RS-485 bus provides communication to system accessories mounted • Built-in RS-232 and USB interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Compatibility • Improvements in SKSS software deliver five times faster The 5820XL signal line circuit(SLC) uploads/downloads supports multiple device types of the same • Two built-in Form C programmable relays rated at 2.5 amps protocol: at 27.4 VDC • SK (System Sensor) • Plex-1 door option combines a dead front cabinet door with a SD clear window, limiting access to the panel while providing • single button operation of the reset and silence functions You cannot mix SD and SK SLC devices on a FACP. INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights 5820XL features a 6 amp power supply required to start a new system. The General Alarm (Red): Flashes when in and maximum battery charging built-in keypad and 5860 remote alarm; solid when alarm silenced capacity of 35 amp hours. An additional annunciator give on-site access to all cabinet enclosure (PN RBB) is required programming. You can also program Supervisory (Yellow): Flashes when a for batteries in excess of 18 amp hours. remotely using the 5660 Silent Knight supervisory condition exists; solid when Flexput circuits on 5820XL control can Software Suite, which is Windows®- supervisory silenced be individually programmed to function based software. System Troubles (Yellow): Flashes as notification circuits, auxiliary power when a trouble condition exists; solid outputs, or initiation circuits that Built-In Digital Communicator when trouble silenced support both 2- and 4-wire smoke detectors. 5820XL features a built-in UL listed System Silenced (Yellow): On when an digital communicator for remote The 5820XL system operates on non- alarm, trouble or supervisory condition reporting of system activity and system has been silenced but not yet cleared twisted, unshielded cable when wired programming. The communicator has in compliance with standard wiring the ability to seize two telephone lines System Power (Green): Flashes for AC practices as called out in the National to report alarms and troubles to a failure; solid when power systems are Electric Code 760-51 specifications for monitoring facility. The communicator normal power-limited fire protective signalling supervises two phone lines and will cables. No special wiring is required. activate a trouble signal if a line failure System Application 5820XL provides 13 preset notification is sustained for more than 45 seconds. 5820XL has one built-in signalling line cadence patterns (including ANSI 3.41) Other communication features include: circuit (SLC) which supports multiple and four user programmable selections retry if communication fails, two phone devices dependent on protocol being for fire alarm notification. number capability, download phone used. Three additional loops can be Two programmable general purpose number capability and Touch-Tone or added using the 5815XL SLC Form C relay outputs are provided on rotary dialing. The communicator is expanders to increase overall capacity. 5820XL. compatible with SIA and Ademco Additionally, the IntelliKnight system Contact ID. The format is selectable by The 5820XL SLC loops support features a built-in walk test and auto- account number. multiple device types, including: account number. programming. Its innovative, dead-front • Addressable photoelectric smoke cabinet design allows for flush or _-_ .,... I detector surface mounting. System maintenance • Addressable ionization smoke is easy to perform. a detector apirwr- ti burg User Interface . �, ,... • Addressable heat sensor ��!The 5820XL built-in annunciator with Aki • Addressable duct smoke detector 80 character LCD display and large inno ran tr • easy-to-use tactile touch ad can be ® ma ELl l Contact module Y touchpad output module used for system operation, IV I 7 • programming and maintenance. It has or , • Addressable notification module five LEDs for alarm, supervisory, • Addressable beam detector (SK system trouble, system silenced and _ protocol only) system power. System operations include silencing alarms and troubles, Approvals • Addressable multi-criteria smoke resetting alarms and the display of detector (SK protocol only) alarm troubles and memory. The NFPA 13, NFPA 15, NFPA 16, NFPA 72: Central Station; Remote • Addressable multi modules (SK system's non-volatile event history Signalling; Local Protective Signalling protocol only) buffer stores 1000 events for viewing Systems; Auxiliary Protected Premises The following advanced sensor from the built-in or remote annunciator. Unit; & Water Deluge Releasing capabilities are available with 5820XL: System operation can be initiated with Service. Suitable for automatic, a mechanical firefighter's key or a valid manual, waterflow, sprinkler • Automatic drift compensation 4- to 7-digit operator's code. supervisory (DACT non-coded) • Maintenance alert Programming signalling services. • Built-in sensor test to comply with The IntelliKnight system offers several Other Approvals: UL Listed; NFPA 72 calibration testing options to simplify and speed up CSFM 7170-0559: 135; requirements programming. The JumpStart® feature MEA 429-92-E Vol. VI; FM Approved minimizes programming 1 INTELLIKNIGHT FIRE ALARM CONTROL PANEL 11EIT[I',OMEIKANEght Model 5820XL Addressable Fore Alarm Control PaneD - iiiimilmo nte_ i '1U i irit 5820)(11 ".": Vihndows Based F. 1 1 �"�1 Facility • Addressable Fire Alarm System2 ' Management Software "` SK (System Sensor) Protocol Device WI • U19ndows Based i ; Up/Download . 11 Software ° • 14 • filL Compatible CS g' r\ s 1------Receiver xx ,.r-, • k ,-..,.si Automation ld `� uras.►�_�,.,.w . _ w=.. - — Internet 5820XL SK-212UD Connection UsorAlarm Ito WiriPS IP Communicator '_- NM 5895XL_ tr... I'1'F'1111Bnt}'t)1CllilClll+ :..•$• 3FormCRe ys t S Fours%Reidy`• 4 I cut ..,.,,. EterlPuntcr 0y' s 11 s: 5815XL a ;!..,:11111111:1. Ps-2S2 ,. y SLC Exaa.dor -' 5860 5824 _ {. > r.; emote t r:nunoatut Pot>rt;t at:3r/al Module r �` W was t 7 S le 2 Wits MadSy;tor) ., ._ xput i . r, I/O Circuits i , _ 5815XL can be inputs i SIC Ecandcr 2 or outputs n 6 Flexput"' r2 g ICU Circuits t] v can be inputs j N Arlt1,,_ ' 1or outputs �, ; 4 • ,,, L, f , a' l 'r , ai `_ s t Ceis.3trobes Hans,ayt s ( l t i. c. I.. .......„ Fi:trStarntts %ormm t nal S1a tied smcyn.rinecros V- ` 1 , I:- 1 ,.. tea. • s r tl i. :. — — .t 1 '_ n. v,a, SK•lon SK-Monitor SK-Iso SK-Control43 SK-Conlml B200SR SK-Acditmalte SK-Zone-6 7::• k c fiddre:,satie Add'esse.t4e Fault isolator A::dressatlie SJporised Coun der Mult:utena Zone I,_rit.-ti'_p MJ,onikr Mociute Mcxi!icdon Cot try: t3_sa srmi4e I;rterf- a 5860 I Detector Mods() nlodtAa Module detector MolJ° Remote Annunt ator ..i.::4)9.0 . a .mow ,w f I I tPl.ijli .-01.ill r SK-Photo SK-Monitor-2 SK•Relaymon-2 SK-Heat 13224RB B224B1 8210LP -•- SK-Photo T Cu al Mon tor Add'essatte SK-Heat-ROR Rai ay is(will o rcrr 5880 Addles.satie Mc ule Dui Monitor SK-Heat-MT Des tine Ease1111 RI LED Driver& rfiotC-lactnc Wffvra Retays Aicreable Irt;,+x l�kdu o Detectcr H�bt rk..ec%ut� ..•� = Ill a: .:1:::.:::- 44— r 11.^i ii ti lit IIIIII I I I 5883 l Relay Intedr:Le Mce:ttla SK-Beam sic-Ivan-19 SK-Pull-DA SK-Duct SK-Mnlmon SK-Relay-6 SK-Zone sic-Relay SK-Beam-T Ad-d'o13s:1-tlh SK-Pull-BA Ad:s l:1e Mcritor RelayCoaxr_.1 Add-o;setta Add rO3s tie Ada-esuaWo Mcmihx• Adrlrensatie Day Module Mcdute 'interface Relay Da.?in Detector Module pail Station De:ertor Modcl'e nodule IMO UM - - .. It '' 5865.4 or 5865-3 Use the 5880 to control up to 4 _ LED n) 1 5883 Relay Interface Modules ( 8�d Stlonn) INTELLIKNIGHT FIRE ALARM CONTROL PANEL IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications S-BUS Accessories Miscellaneous Accessories Electrical 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz, 2.5A or LCD display keypad and firefighter's User-friendly Windows software for 240 VRMS at 50/60 Hz, 1 .4A keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using Total Accessory Load: 6A @ 27.4 VDC, and 5860R is red. a PC. Upload and view panel account power-limited 5815XL Signal Line Circuit Expander information, event history, and detector Standby Current: 215 mA The SLC expander is used to add more status. Alarm Current: 385 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite system. 5820XL supports three (SKSS) Flexput Circuits: 5815XL's. Each 5815XL can support 99 Powerful end-user facility management Six programmable circuits which can be SK detectors and 99 SK modules or software allows viewing of detector programmed individually as: 127 SD devices. status and event history via modem or Notification circuits: 3A @ 27.4 VDC 5895XL Intelligent Power Module direct connection. per circuit, power-limited Adds 6 amps of power, 6 Flexput I/O Plex-1 Auxiliary power circuits: 3A @ 27.4VDC circuits and 2 Form C relay circuits to a Dead front cabinet door with clear per circuit, power-limited 5820XL system. window to limit access to the FACP. Initiation Circuits: 100 mA @ 27.4VDC 5496 Intelligent Power Module RBB per circuit, power limited A 6 amp notification power expander Remote battery box accessory cabinet. that provides four power-limited notifi- Use if backup batteries are too large to Physical cation appliance circuit outputs. fit into FACP cabinet. Dimensions: Flush Mount Dimensions: 5880 LED/lO Module 16" W x 10" H x 6" D 14.5"W x 24.75"H x 3.9"D Features 40 LED outputs, 8 normally (406 mm W x 254 mm H x 152 mm D) (36.8 W x 62.9 H x 9.8 D cm ) open dry contact inputs, and one piezo SD505-DTS-K output. Remote test switch. Used with Overall Dimensions: 5865-3 and 5865-4 SD505-DUCTR. Provides remote key 16.2"W x 26.4"H x 4.2"D Remote LED Annunciator operated test function and annunciation (40.6 W x 67 H x 11 .8 D cm) Features 30 programmable LED (15 of detector alarm. red and 15 yellow) outputs, and a piezo SD and SK Devices Weight: 28 lbs. (12.8 kg) sounder. The 5865-4 adds a silence See the specification sheets listed Color: Red and reset switch to the package. below for a complete listing of the SD Battery Charging Capacity: 7.0-35 AH 5883 Relay Board and SK devices. Features 10 general purpose Form C 53624 SD Devices Data Sheet Battery Size: 18 AH max allowed in relays. Used with 5880 module. 53623 SK Devices Data Sheet control panel cabinet. Larger capacity 5824 Serial/Parallel Printer batteries can be housed in RBB Interface Module accessory cabinet. Provides one parallel and one RS-232 serial port for connecting a printer to Telephone Requirements: the 5820XL. Use to print a real-time log FCC Part 15 and Part 68 approved of system events, detector status Type of Jack: RJ31X (two required) reports, and event history. Interfaces with building control system. SILENT This document is not intended to be used for installation purposes. We try to keep our Made in America KNIGHT or information up-to-date and accurate. We cannot cover all specific applications tvii or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472 PN 350210 Rev H2 by Honeywell Phone: (203)484-7161, Fax: (203) 484-7118. www.silentknight.com. © 2012 Honeywell International Inc. IntelliKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight CHANDLER'SSQUARE ANAC ORTESWAS HINGTON �r�r�r��nn�r� FIRE ALARM WORK AREA NOV n 4 2�1 ....it.:�LLnu U LSL. QEF� g as rl s 1, 1 t e £. 7 7 b /` ' PR()JECT LC?CATI t 0 I ,8:7-1:-'''1 ;':::'':Ii. :;!.::: ".. 1 k £,o de t. r�-` — a a 24 ! µby„,@ i 'a' Y W'! k j S 6 9d t Yoe . 1 'i4 a,_i a s ib?3� yl:r r S<F�bEs �; i r j r a sn c , L_FACP i s i { � s u ,, �k L `4 7 � Lob { 0 2 5 10 SITE PLAN/KEY PLANrt SECOND FLOOR PLAN4:: i Ey N SCALE: 1/8" = 1' I CFIRE ALARM CONTROL PANEL SK-5208 (EXISTING) AES RADIO 7744TO AC HI J1 I'—� RESET CD X X O _ _ _ , .z17 c -, a VICINITY MAP SWITCH T_ � , II Accessory& -g CD @ �N SCALE: NTS { Programmer Port '- • r � C!) g • S't TROUBLE &. . z z°.azakaeM.ry CZ J4,Antenna S$ Tr SILENCE Cut/Trouble Output Device & Wiring Notes: 7067 INTELLITAP-II MODULE MIENI� $ Form C Relay,Fail All device wiring to be Class B configuration and not to exceed Secure Contact maximum distances per wire gauge (16 AWG = 4900 Ft). •I ' . ' - hla tion devices to be set to a threepulse Rating:24vdc, All audible notification �; • Resistive 5mporal pattern. C E R T GNRDGYBN TiT1 R1D. All audible and visual notification devices serving the sameIlls 100000000001 9 • area are to be synchronized. PHONE LINES DESIGN CRITERIA 1, IT xvN :, Z1 G Z2 Z3 G Z4 : 4 Y s € 14 �, IINSTDESIALLED PER ED PER INFPA FC- 0722 2013IOEDITION ie s+ i�£ � � � 16.5VAC +BAT six t — INSTALLED PER NFPA 70 2014 EDITION To LC Loop T: phone lines Ground start, ., relay oc e NOTE:ALL 7744 resistors 2.2k Ohm Bernie Stebar SCOPE OF WORK 423 2"''f2 D 311rs 413121 11€ 9 7 x6 5 .. 12V 7AH ' 2014.11.04 07:41:11 -- - A - + X G X 0 X,0 X 0 X 08'00' .rf Vo i °.. . I ` & RELAYS BATTERY SIGNATURE — COMMERCIAL ALARM & DETECTION (CAD)WILL EXPAND THE EXISTING FIRE ALARM PANEL FOR WIRELESS RADIO GENERAL TROUBLE RELAY I BERNIE STEBAR TRANSMISSION FOR REMOTE EMERGENCY DISPATCH OF FIRE 16.5VAC, 4OVA - — ALARM EMERGENCIES. THIS WILL BE ACCOMPLISHED THROUGH THE USE OF A TWO-WAY RADIO SUBSCRIBER UNIT mic NAME GENERAL SUPERVISORY ALARM RELAY Transformer t TRANSMITTING ON FREQUENCY 465.9875 mhz LICENSED TO NICET IV #116393 ALARM CENTER OF LACEY WITH THE FCC. THIS UNIT WILL eg —� GENERAL FIRE ALARM RELAY CERTIFICATIONI - NO. COMMUNICATE TO CENTRAL STATION THROUGH A MINIMUM OF a 11/3/2014 TWO GOOD PATHS WITH A NETCON OF 5 OR LESS.THESE PATHS W CAN BE DOCUMENTED UPON REQUEST OR VERIFIED DURING FIRE ALARM SYSTEM RISER DETAIL DATE_. ...._APPROVALS FINAL INSPECTION. oC SCALE: NTS W FIRE ALARM OC 4 0 CABLE CODES Legend ge CONTRACT WITH __ Device end REVISIONS � , H CODE FUNCTI3N DESCRIPTION 'NEC TYPE CABLE ROUTING __._ w_ NO. DATE 13Y REASON 1-0 REVISION COMMERCIALALARM & flTEGT�QN INC, SYMBOL TYPEANUEACTURERee MOUNTING INC3TEs count CHANDLER'S SQUARE a ' NAC NOTIFICATION APPLIANCE CIRCUIT 1-2/C �i4 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY ---} -.-�.�.. � mm . " ;1 17199 BENNETT ROAD SLC SIGNALING UNEUCIRCIUITUIT 1-4�C #16 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY I I AES RADIUM. CONTROL PANEL SILENT KNIGHT SK-5820xL 72" AFF EXISTING _ FRCP FIRE ALA US FIRE ARM SBUS CI _ 1 -- _� __-. _. ......__ — — _ _.._�__ \ MT VERNON, WA 98273 O AES AES-7788F 72" AFf NEW �, -- — — 1300 0 AVE i -I LICENSE #C€}MMEAD961LS W �+ p o� AES RADIO ANNTENA AES I LOCATED ON AES PANEL _11_-_. ANACORTES, WA 9822 .\.: PHONE: (360) 848-1533 FAX (360) 848-1072 Q _ _ -__ __ __ — _ — - -�-�---- - __ __ ___- CHANDLER'S SQUARE Z 4 — - PROJECT MANAGER: John Fuik AES RADIO I _ PHONE : 360-293-1300 U _ FAX : 1300 O Ave — SUPERINTENDENT: Anacortes, WA 98221 AUTHORITIES HAVING JURISDICTION : PHONE : N City of ANACORTES ! Department of L&I DR AWN BY: CHECKED BY: DATE: SHEET: JOB NO.: 4 — — �JHmm BS 10/31/2014 1 OF 1 14-221 e-