Loading...
HomeMy WebLinkAboutPermit File 415 O Avenue (2) • 1' Y City of Anacortes Invoice/Permit#: BLD-2014-0328 • 904 6th Street Due date: 07/23/2014 P.O.Box 547 Issue date: 07/23/2014 ` 0'•• ; ' Anacortes, WA 98221-0547 Expire date: 01/19/2016 ., � (360) 293-1901 Job Address: 415 0 AVE Permit Type: Fire Alarm Permit ANACORTES WA 98221-1542 Project: APN: P55051 Remarks: Modification to commercial fire alarm and detection at Anacortes Cinema. Owner: RADIUS ANACORTES PROPERTIES LL Contractor: COMMERCIAL ALARM & DETECTION Address: PO BOX 1641 Address: 17199 BENNETT RD OCEAN SHORES WA 98569-1641 MOUNT VERNON WA 98273-9789 Phone: Phone: (360)848-9093 License#: General Information: Fees: Building Valuation 980 Building Permit Fee 38.75 Plan Review Fee 20.31 State Building Code Fee 4.50 Total Calculated: 63.56 Deposits/Receipts: 0.00 Total Due: 63.56 r —I 7.1 r' Cr.• m m X"W.: V --J P IA ,U t•.) -4 �. rt t '- 1 1 In C r1- -P J A.. e-• Z tJ f•• [i = C• D 4..1 Z' t•. i_i 44 V •i1D co . tJ r t•: + r l O) s= �• 2> •v 3 rt ri- it Z • c) I Tt n to THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DZ{Z 61t't CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMM, N 9• kl HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL P.F0; 840PStS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OW N rr ,rHE GRANTING OF A.PERMIT DES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHEFrSk1 LOCAL LAW,REGULATING C 14STRUCTION OR THE PERFORMANCE OF CONSTRUCTION. —1 -P t•.' m \3\Milt," t:i 1 : r:a r rta()mid'OF OWNER OR AUTHORIZED AGENT ISSUED BY � v n .. %ATURE �` �` Commercial Alarm & Detection, Inc. Transmittal I �I 17199 Bennett Road Mount Vernon WA 98273-9789 Date: 07-16-2014 360 848-1533 License: COMMEAD961LS To: City of Anacortes Project: 14186 Permit Center Anacortes Cinemas AES P.O. Box 547 415 O Ave Anacortes WA 98221 Anacortes WA 98221 Prepared By: JOSHUA HARROLD Item Quantity Description 1 Permit App 3 Plans 3 Cutsheets JUL 162014 -------------- Please sign and date this form as proof that you are in receipt of the above listed items. Return form to Commercial Alarm& Detection, Inc. Signed: Date: 1, 4 ( I ...)..._ Fire Sprinkler/Alarm Permit Application , —, f_ City of Anacortes Building Department i eJi i , rut i H it 904 6th Street — Anacortes, Washington• A'ki ., .,, .. . - -- ,. TrAk:. tI Phone: (360) 293-1901 Fax: (360) 293-1938 ? r:5 ,5J UL l (i 2014 It uayo— t LANTD ZT►. E ��1 Ta2%site Address: 415 O AvenueParcel No.: P129724 Lot: Block: Addition: Owner Owners Name:RADIUS ANACORTES PROPERTIES LLC Phone No.: Address:PO BOX 1641 OCEAN SHORES,state:WA Zip:98569 Tenant Tenant's Name:Anacortes Cinemas Phone No.: Contractor Information Contractor:Commercial Alarm and Detection Phone No.: Mailing Address: 17199 Bennett Road Mt Vernon, State:WA Zip:98273 State Sprinkler Certificate Level and License No.:COMMEAD961 LS Exp. Date: 11/02/14 General Information Please Check: Fire Alarm I Fire Sprinkler ❑ Modify Existing System 0 Install New System ❑ Underground Fire Line ❑ Value of Project (labor and materials) $980 Required Submittals Three(3):Scaled construction drawings showing the following elements along with their dimensions 1. Floor plan indicating the location of devices and appliance, end of the line devices, conduit wire runs, conduit size and number and size of devices. The zone indication shall be placed adjacent to the appropriate end of the line device. 2. Interior, exterior and underground fire alarm/sprinkler components 3. Transition from exterior to interior. 4. Manual fire alarms and strobes(including installation height) 5. Fire alarm control panel location, riser locations and control valves 6. Door hold-open device 7. Heat and smoke detectors(identify type)duct detectors 8. System Calculations and manufacturers information on system components 9. Fire Sprinkler tamper 10. Water flow an control valves 11. Sit P (Sh FDC, PIV locations) Signature: /^ ,: Date: 7/i I pphcan.t o r Owner (ii Updated November 4,2009 FIRE ALARM CONTROL PANEL ELy11 4 °i,.t i �� SILENT as ii Mod& 5208 10 ��� JAL 1 � 1JJ � KNIGH Fire Alarm Control Panel -_--- with Digital Communicator by Y Honeywell --------------- g. The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features ° Built-in synchronization for o 10 zones, 8 Class B (Style B) and 2 appliances from AMSECO®, I Class A (Style D) or Class B (Style Gentex®, Faraday, System Sensor®, • B) zones, expandable to 30 zones and Wheelock® • O Supervised zone expanders and I/O ° Programmable date settings for modules can be mounted remotely Daylight Saving Time w-,a WNW i • from the main control panel ° Clock source setting options for 50 o Event History Buffer (150 events) Hz, 60 Hz, or internal (uses the • ;,. with date/time stamp panel's internal clock) O All zones are compatible with 2- or Specifications 4-wire detectors �yi ° 8 selectable/programmable output Operating Voltage: 24 VDC patterns for notification appliance Primary AC: 120 Vrms @ 60Hz, 2A circuits Total DC Load: 6 Amp o Built-in Digital Alarm Communicator Current Draw: Transmitter (DACT) Standby: 140 mA o 4 Notification Appliance Circuits Alarm: 460 mA • 4 programmable general purpose Flush Mounting Dimensions: s,«Z relays Height: 24.75" (62.9 cm) -.v.; -� _�- . . O Programmable smoke verification, Width: 14.5" (36.8 cm) ,,,1,,.,� pre-alarm delay, cross zoning and Depth: 3-7/16" (8.73 cm) enhanced verification mode features with 5/8" protruding that can help minimize false alarms Overall Dimensions: SK-5208 o Programmable from the built-in Height: 26-3/8" (67 cm) 0 Plex-2 Door Option control panel touchpad, remote Width: 17-3/16" (43.66 cm) ° SK-SCK Seismic Compliance Kit annunciator, or Windows® SKSS Total Depth: 4" (10.16 cm) downloading software Operating Temp: 32° to 120° F Listings and Approvals • Direct connect port for on-site (0° to 49° C) ° UL Listed up/downloading with Windows° Humidity: 10 - 93% noncondensing ° CSFM Listed SKSS downloading software ° MEA approval 429-92-E Vol. XIII o Built-in walk test feature Opti ooial Accessories ° OSHPD (CA) OSP-0065-10 o Single or dual interlock water ° SK-5235 LCD Remote Annunciator releasing capability ° SK-5217 10 Zone Expander o Plex door option combines a dead (2 max. per system) front cabinet door with a clear ° SK-5280 Status Display Module (8 window, limiting access to the panel max. per system) while providing single button ° 5220 Direct Connect Module operation of the reset and silence ° 5824 Serial/Parallel Printer Interface functions Module o Programmable AC trouble relay ° SKSS Downloading Software FIRE ALARM CONTROL PANEL Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 ,` Direct Connect _,�- ��,;��_,rT®- --- For On-Site Programming 2 Class A (Style D) —4,i'' r^ , x.: I "'$— or Class B (Style B). r` ' i_$ ,.P p ; m., Programmable Initiation Circuits F,a; .V -�' �g' k ,4 Form C Relays 14111 PuI 8 Class B (Style B),,_ i WM ... ® .. .i. . _� Notification Initiation Circuits ran en ' *4 ,. F-: ® . Appliance Circuits H..a ....tom AIM 0 H u °: ' 5235 Remote l.,- " y-f`�` „.�R ` Annunciators .-,E,., 1" 4.3.E .....�......,.. .... :', SBUS Devices t ' i , i... :1 5280, 5217, & 5824 1 r'": -) To AC + - This document is not intended to be used for installation purposes.We try to MADE IN AMERICA SILENT keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are FORM#350318 Rev E subject to change without notice. For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118. For Technical support,Please call 800-446-6444. www.silentknight.com - L1�JLI LJ.3�_Ll AI* A E �,� I aes corp.com SECURITYfJUL_1 6 2014 CORPORATION INNOl,AEION Wireless Fire Alarm Communicators for AES-IntelliNet 7—igg , FEATURES Advanced Wireless Alarm Monitoring • UL Listed commercial fire As expensive dedicated landlines, required for alarm applications. UL864 compliance, disappear and the future • Meets NFPA-72 requirements • Direct reporting to AES of GSM for alarm transmission becomes receiver across AES IntelliNet increasingly uncertain, the AES IntelliNet mesh mesh radio network radio network continues to offer unmatched • Each subscriber acts as transmitter/receiver/repeater reliability and speed in delivering wireless • Simple and fast activation alarm signals to a central station without on network ® r> any third-party fees or reliance on networks • On board status LEDs for h• easy setup operated by companies outside the alarm • 8 programmable zone b «s industry.The 7788F/7744F Series Subscribers inputs-7788F - provide the wireless communications link • 4 programmable zone inputs and 4 reverse polarity between the fire alarm panel and the central inputs-7744F station receiver. Ideal for most commercial • Easy programming via AES fire alarm applications, each 7788F/7744F handheld programmer or PC • Rugged metal housing ideal Series Subscriber is housed in a full-sized, for any commercial fire red, locked steel cabinet and supports a alarm application range of alarm panel inputs, including EOL • Narrowband compliant fire, EOL supervised, and direct voltage from the panel (non-fire applications). MODELS 7788F/7744F-ULP WITH AES-INTELLIPRO FIRE ` z`€ rq` (? t ALSO INCLUDES AES Subscribers offer fully-supervised operation that includes monitoring of • AES-IntelliPro Fire transmits operating power(both primary AC and battery back-up) and the connection to full alarm data from virtually the mesh radio network. Each subscriber"checks-in"with the AES central station any fire alarm panel digital receiver at least once every 24 hours. The supervision check-in time can be set to communicator • Alarm format support for as often as needed for the application, as appropriate for the network. Because Contact ID, Pulse, as well as the central station operates the wireless network, there is no additional cost for air Bosch Modem Ile and time to transmit supervisory signals. Modem Illa • Easy installation in AES subscriber• Operates in applications with C ® US ■ d, ■ �' or without a phone line LJ - •. -. cs6sA _ a ,�.,.•,., C�l .4, � . LISTED NFPA® 1" "`` HOW TO ORDER r)()rting from Alarm PanelDigs 1 Dialer r Moe scri J . Models 7788F-ULP and 7744F-ULP come equipped with an IntelliPro-Fire Full 7744F 4 Zone Fire Alarm Data Module (AES-7794) which enables reporting of full alarm data captured Subscriber with 4 reverse polarity inputs from the alarm panel's digital communicator. IntelliPro-Fire supports most alarm 7744F-U? 7744F Fire Alarm communication formats including Contact ID, Pulse, as well as Bosch Modem Ile and Subscriber with AES-IntelliPro Modem II1a2 (when converted to Contact ID format). Fire full data module 7788E 8 Zone Fire Alarm 7/ I$ "'i / /. 4 * Series Subscriber Technical Specifications for 778 F 774 i ;, SubscHber 7788F-ULP 7788F Fire Alarm Dimensions Reset Button Subscriber with AES-IntelliPro 13.25"H x 8.5"W x 4.3"D ° Located on main circuit board. Fire full data module (34cm H x 21.5cm W x 11cm D) Operating Temperature Optional Accessories Weight ° 0° to 50° C (32° to 122°F) 7041E Subscriber Handheld ° Approx. 7 pounds (3.2 kilograms), Programmer excludes battery Storage Temperature ° -10° to 60° C (14° to 140°F) Radio Frequency 7794 AES-IntelliPro Fire Full Data o Standard Frequency Range: 450-470MHz Relative Humidity Module (others available in 400-512MHz range) ° 0 to 85% RHC, Non Condensing 1640 Plug-in Transformer: ° Output Power - 2 Watts 16.5VAC, 40VA Antenna 794 ALSuIngelliPt"o Fire • Included 2.5 db tamper resistant antenna Packaged with 7744F4 LP and 7788F-ULP mounts on enclosure About AES Corporationinput/Output �uectoc�n Established in 1974, AES ° Multiple remote antenna options available RJ11 connection to AES subscriber for module Corporation empowers Power input data and power companies to grow profitable ° 16.5VAC, 40VA transformer (not included) (AES ° RJ11 connector for Handheld Programmer/PC alarm monitoring businesses, 1640, ELK TRG1640, MG Electronics MGT1640 - programming UL Listed for use) ° RJ31X Telco connections - T and R both in and out and government agencies to via terminal strip and RJ45 enhance securityanywhere Backup Battery y ° Will charge 12V battery up to 7.5 AH. Requires ° Alarm Panel digital communicator T and R both in the world. By providing in and out via terming strip and RJ45 the industry's only patented 12VDC 7.5 AH battery for UL 864 ° Trouble output: Form C relay detects if operator-owned and controlled Subscriber is off the network private wireless mesh networks, Alarm Signal inputs (subscriber) • 7788F - 8 individually programmable zones AES ensures superior reliability, ° 7744F - 4 individually programmable zones and Alarm Formats low TCO and optimal RMR while 4 reverse polarity inputs ° Support for Contact ID and Pulse formats as well reducing dependence on service as Modem Ile and Modem II1a2 converted to CID provider infrastructures. UL Standards Size The company's flagship ° UL 864 Edition 9 - Standard for Control Units ° 2.8 x 5.0 inches (7.1cm x 12.7cm) AES IntelliNet systems are and Accessories for Fire Alarm Systems • UL 365 - Standard for Police Station Connected Power Requirements deployed in over a half million Burglary Alarm Units and Systems ° 12 VDC nominal - primary and backup power locations worldwide. ° UL 1681 - Standard for Central Station provided by the AES 7788F/7744F or other Burglary Alarm Units Subscriber Antenna Cut ./C ommunicatkon Trouble Output o Form C relay; fail secure; rated for 24 VDC 1A resistive For more information, go to www.aes-corp.com or call (800) 237-6387 or contact us at sales@aes-corp.com © Copyright 2014 AES Corporation I AES-Intel/iNet is a registered trademark of AES Corporation Hr07.5y_.; ANACORTES CINEMAS ANACORTES, WASHINGTON fililEti.TiEriirg::_izili AES RADIO i A JUL 1 6 2014 1 ............._...........-----------_ I AES RADIO 7788 ._ (1) 0 0000 > '1 [7] RESET Q.) / SWITCH KZ 0 Accessory& o:s a) co oltiE C/) Programmer Port ,.. Alma J4,Antenna ',,--.. 0 CutlTrouble Output L— 7067 INTELLITAP-II MODULE 1 I -(A.°7C5C Form C Relay, Fail Secure Contact Rating:24vdc, la I c.) Resistive < C E R T GIRDGYBN T1 R1 if 1 F .1:::::.',:::::: ALARM CONTROL PANEL 100 0000000i 9 It-5208 (EX1 ST1 Nii ii::: ) PHONE LINES zi G Z2 Z3 G Z4 Z5 G Z6 Z7 G Z8 1 6.5 V A C +BAT .,11ilii 16.5VAC, 40VA . - " "--.---,!Fi ;?: 1111k FLOOR PLAN 0 2 5 10 , ,z,i,, -E,1ii.:1 -p 1 .... . ",:SCALE: 1/8" = 1 ' .._.:: ...„ „,..,:. , RELAYS Transformer -7,,i,i : ,,,,•-k.., • - , : .: I GENERAL TROUBLE RELAY 12V 7AH GENERAL SUPERVISORY ALARM RELAY BATTERY .-.:., lAiriil i ' NOTE: ALL 7788 resistors 2.2k Ohm • , PROJECT LOCATION giM I i I GENERAL FIRE ALARM RELAY : •:,..! • " , _ _. .. , ,:e , ..•', •—• - , . .,, . . . . . __. _ - --- --- -,.•-.„-,,,,-„:.....,4A::-.- - - - - .. ' 7.,. .,,,-,'.,:," ; , ,-> i . •iz-;:.t,.-- ,00,-:, - • ts,..: ::?....zz,i i -77.F-7,,i,' arepat r.,./:•..1.E.K.,.:T ; • -' *13 4 .1,4* Eltaiiie•E°;44 i•„,10,§901*.: ' ', •:",-,, : i::E::i::1,,i - .,..--,,. . : . Device & Wiring Notes: : .: ,::,.,.,.„,4(kst...,. .,.,.. : ', -,,- ,lz'' '• • . 11 1 til', „„,i-,ii. .:i4,4,5,., 0,88,,A,,•,,,... •:,5';;. •• All device wiring to be Class B configuration and not to exceed maximum distances per wire gauge (16 AWG = 4900 Ft). 20 VAC POWER 0 • , , , .i , ,-../ .,,,, , ,:, : :N•L; 1, All audible notification devices to be set to a three pulse . •,,,..,,...: , !,,,..ii ..-.:: CONNECTION . .„ temporal pattern. LI i, ,,, • , ai.il .,'. .4 :ii,," , •'' 1 ,,,,-?;,,,, .:-.,",1 , K ....,... , : All audible and visual notification devices serving the same ,.:. . C?.-f:::...t....L::::-.17,-,:i:.:77'':,'.'. •:::',,,,PVIIiJ I 1 1.....i , ; : . ' - BATTERY ECTION area are to be synchronized. ,.',,.: ,:• ' . CONN (2) ::7,40,,,,''''' ''' • • , 2.. _....c_..,.:.:-;I:----::::::::-. ..-c±i::„p-mi , -.... !;:?. .‘ - -- I .,,, 12V-7AH DESIGN CRITERIA e 0& DESIGNED PER IFC -2009 EDITION ;',N1 sl • . •• , ,.. . ,.. INSTALLED PER NFPA 72-2010 EDITION ' :' . ' •,.. INSTALLED PER NFPA 70-2008 EDITION FIRE ALARM SYSTEM RISER DETAIL .._ m,... ...m .___ .... — ...m —I . . SCOPE OF WORK ,, ,- .,:.;,:: •.,1 SCALE: NTS . . 1 ,,,,,,,,,,,, ,„:__ , CITT Or-',AtilkOOkTES PERMI I t..4:,-.61I I.-2,Ft , — I COMMERCIAL ALARM & DETECTION (CAD)WILL EXPAND THE SIGNATURE: EXISTING FIRE ALARM PANEL FOR WIRELESS RADIO „ APPROVED PLANS BERNIE STEBAR I TRANSMISSION FOR REMOTE EMERGENCY DISPATCH OF FIRE s'i 1 ALARM EMERGENCIES. THIS WILL BE ACCOMPLISHED THROUGH r,•:4-- L_LT, 20\4, o .:../ .,:,. I ::- NAME THE USE OF A TWO-WAY RADIO SUBSCRIBER UNIT :, PERMIT NO.. TRANSMITTING ON FREQUENCY 465.9875 mhz LICENSED TO •i,','1i- r,...! 0 i ---- 7-\ NICET IV #116393 ALARM CENTER OF LACEY WITH THE FCC. THIS UNIT WILL 1,..i.:t r,sS hack 4 — 1 ilD VICINITY MAP -,,0ealer Arlacoit s ADURESS%„...,4.1 \„1 ,,,Y ,,,,_11,,,,tfr,4-77-7_, ,_ CERTIFICATION NO. 1 TWO GCOMMUNICATEOO DPAT-fH"Os CENTRALWITH AN STATIONETG0 N OF THROUGH OR OR UL GE LESS. SA. THESEMINIMUM PATHS OT HE s 1 2 1 , I CAN BE DOCUMENTED UPON REQUEST OR VERIFIED DURING Ct N SCALE: NTS APPHOVED By._ . -L, __ _ _ ,,-- 7/15/2014 DATE FINAL INSPECTION. -1 SUBJECI 10 . t LD INSPECTION. OVERSIG i'fT)P 1701DF IP Nc( r N( ! .I.JDECii , ; APPROVALS ........ AES LLI 4 IP, V 101,ATIrvy z CABLE CODES Device Legend REVISIONS CONTRACT WITH . *' --.-1 COMMERCIAL ALARM & DETECTION, INC. r..) CODE FUNCTION DESCRIPTION NEC TYPE CABLE ROUTING SYMBOL MANUFACTURER TYPE , 1 ,MODEL MOUNTING NOTES Count • NO. i DATE BY REASON FOR REVISION • -- FIRE ES :131116l 17199 BENNETT ROAD Cl) NAC NOTIFICATION APPUANCE CIRCUIT 1-2/C #14 AWG FPLR OPEN OR COMBINATION OPEN AND RACEWAY --- :::,msotw - , IFACPI SILENT KNIGHT FIRE ALARM CONTROL, PANEL SK-5208 72" AFF EXISTING 1 -.,,'MIR MT VERNON, WA 98273 ILI SBUS.,. FIRE ALARM SBUS CIRCUIT 1-4/C #18 AWG FPLR OPEN OR COMB/NATION OPEN AND RACEWAY I 1 AES AES RADIO AES-7744F— 72" AFF ' NEW all =El ----- PO BOX 283 i''''---140! LICENSE #COMMEAD961LS I' SLC SIGNALING UNE CIRCUIT 1-4/C #16 AWG FPLR OPEN OR COMB/NATION OPEN AND RACEWAY / Ce O\-)E) AES LIES RADIO LOCATED ON AES FIANEL 11111111111111111111111111111111M MT VERNON, WA 98273 ._...7-_-..-."--- E&INVEliE) PHONE: (360) 848-1533 FAX: (360) 848-1072 _ _, _ — ANACORTES CINEMAS t) 4 MIN ad PROJECT MANAGER : Christine Love Z 111111 ...... .IIIIIIa11I1Il1I=1I11I1M1111 M I _ ....._ _......__ - PHONE : 360-293-6620 . ' I FAX: 4--1-5- 0 Avenue 4ci)SUPERINTENDENT: J Anacortes, WA 98221 03 I - . , , ... , - AUTHORITIES HAVING JURISDICTION : City of ANACORTES / Department of L&I PHONE : FAX : ---- pRAWN BY: CHECKED BY: JH . -- BS _ r• DATE: 1------SITEET: ... , - JOB NO,: I i 7/14/2014 I 1 OF 1 1 14-186 r' i i