Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD-2025-0612 - SOLAR PERMIT
For inspections, please call (360) 293-1901 PARCEL: P56717 LEGAL DESCRIPTION: APPLICANT: Ambia Energy, LLC 335 South 560 West Ste 100 Lindon, UT 84042 8774127929 OWNER: IVERSON DANIEL J 501 37TH ST ANACORTES, WA 98221 VALUATIONS: Estimated construction cost 19683.00 $19,683.00 $19,683.00Total: FEES:Paid Due Plan Review Fee $208.81 $0.00 State Building Code Council fee $6.50 $0.00 Building Permit Fee $321.25 $0.00 $0.00Totals : REQUIRED INSPECTIONS Solar Final $536.56 BLD-2025-0612 SOLAR PERMIT ISSUED: EXPIRES: 09/03/2025 09/03/2027 PROJECT NAME: 5013IVER SITE ADDRESS: 501 37TH ST ANACORTES * If you answered yes to all of the above questions, your PV installation is eligible for a building permit. CONDITIONS Page 1 of 1Printed by : Jennifer Watson on: 10/02/2025 03:35 PM City of Anacortes, WA 904 6th Street Anacortes, WA 98221 (360) 293-1901 http://cityofanacortes.org/ 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Heath J. Harpster, PE, P.Eng office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com August 27, 2025 Ambia Energy 335 South 560 West, Suite 100 Lindon, Utah 84042 Re: Engineering Services Iverson Residence 501 37th Street, Anacortes WA 10.935 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Built in place wood trusses at 16” on center. All truss members are constructed of 2x4 dimensional lumber. Roof Framing: Assumed 2x6 dimensional lumber at 24” on center. Roof Material: Metal roofing and membrane roofing Roof Slope: 6 and 25 degrees Attic Access: Accessible/Inaccessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 psf • Live Load = 20 psf (reducible) – 0 psf at locations of solar panels • Ground Snow Load = 20 psf • Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 98 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2018 Washington State Residential Code. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Pegasus Solar installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The system utilizes the Pegasus SkipRail racking system. Please reference the stamped plan set for rail and mounting locations. 3. The maximum allowable withdrawal force for a 5/16” lag screw is 229 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of 2½” embedment will be adequate and will include a sufficient factor of safety. 4. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48” on center. E. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent “Sunmodo Installation Manual”. If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. System will be attached to the metal roofing material utilizing the patented Sunmodo connection. Installation of the connections shall be in accordance with the manufacturer’s recommendations. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48” on center Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2018 Washington State Residential Code, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE Washington License No. 20111163 Washington UBI # 604981384 Signed 8/27/2025 · · · · · Signed 8/27/2025 TRUE NORTH · · · · · HATCHED AREA WILL PROVIDE A FIRECODE PATHWAY TO COMPLY WITH IFC 605.11.3.2.1 HOUSTON NOTE: NO ENCROACHMENT INTO EASEMENT BY NEW SCOPE OF WORK (SOLAR PANELS) COM MSP AC UM HATCHED AREA WILL PROVIDE A FIRECODE PATHWAY TO COMPLY WITH IFC 605.11.3.2.1 HOUSTON NOTE: NO ENCROACHMENT INTO EASEMENT BY NEW SCOPE OF WORK (SOLAR PANELS) RS-1 RS-2 PV-2 A PV-2 B COM MSP AC UM DESIGN ADDENDUMS TO STANDARD TEMPLATE BASED ON CITY, STATE, UTILITY, AHJ, OR PREVIOUS PLAN REVIEWER COMMENTS IF THERE ARE CONFLICTING NOTES, ADDENDUMS TAKE PRECEDENCE OVER STANDARD TEMPLATE NOTES Signed 8/27/2025 D C *# OF ROWS MAY DIFFER SHOWN 3 DRAWN FOR EXAMPLE DIAGRAM* *# OF ROWS MAY DIFFER SHOWN 3 DRAWN FOR EXAMPLE DIAGRAM* *# OF ROWS MAY DIFFER SHOWN 3 DRAWN FOR EXAMPLE DIAGRAM* A B NOT TO SCALE ATTIC INFOB PV MODULE MOUNTING CLIP RAFTER/TRUSS VPSCALE VIEWNAMEA RAIL (1) 5/16" x 4.0" LAG SCREW Signed 8/27/2025 VAULTED CEILING D C *# OF ROWS MAY DIFFER SHOWN 3 DRAWN FOR EXAMPLE DIAGRAM* *# OF ROWS MAY DIFFER SHOWN 3 DRAWN FOR EXAMPLE DIAGRAM* *# OF ROWS MAY DIFFER SHOWN 3 DRAWN FOR EXAMPLE DIAGRAM* A B NOT TO SCALE ATTIC INFOB PV MODULE MOUNTING CLIP RAFTER/TRUSS VPSCALE VIEWNAMEA RAIL (1) 5/16" x 4.0" LAG SCREW 6 Signed 8/27/2025 MOUNTS TO BE SPACED AT 48" O/C MAX DESIGN ADDENDUMS TO STANDARD TEMPLATE BASED ON CITY, STATE, UTILITY, AHJ, OR PREVIOUS PLAN REVIEWER COMMENTS IF THERE ARE CONFLICTING NOTES, ADDENDUMS TAKE PRECEDENCE OVER STANDARD TEMPLATE NOTES ADDENDUM #54 - : PER 2023 NEC VERIFICATION OR INSTALLATION OF A SURGE PROTECTER SHALL BE DETERMINED AT INSTALL. SITE SURVEY PHOTOS INDICATE A SURGE PROTECTOR BEING ON SITE (2023 NEC 215.18) ADDENDUM #55 - : 2ND GROUND ROD TO BE INSTALLED NO MORE THAN 6 FEET AWAY IF NOT ALREADY PRESENT (PER 2023 NEC 250.53). NEEDS TO BE CONNECTED TO THE EXISTING GROUND ROD WITH AN IRREVERSIBLE CRIMP BATTERY INFO MANUFACTURER PART NUMBER NO BATTERY TOTAL ENERGY (kWh) USABLE ENERGY (kWh) CAPACITY (Ah) NOMINAL VOLTAGE (V) VOLTAGE RANGE (V) MAX POWER (kW) WEIGHT CAUTION ! N Location preview Notes Project information Installer Ambia Project name 501 37th St Design Project address 501 37th Street, Anacortes, WA 98221 USA AHJ/ASCE City of Anacortes / 7-16 Project number -Wind / Exp. Cat. / Snow 98.0mph / C / 20 psf Equipment type Module Longi LR5-54HABB-405M Inverter - Battery -- Summary Total modules 27 Total watts 10935 W Total attachments 49 Arrays Array 2 Roof: 25° Gable R-panel SkipRail: Yes Array 1 Roof: 6° Gable Other SkipRail: Yes ENGINEERING PACKET 501 37th St Design | Bellingham Area region | Anacortes Project dashboard: 501 37th St Design | Bellingham Area region | Anacortes Produced by Kyle McOmber from Ambia on 07/02/25 © 2025 Pegasus Solar Inc. All Rights Reserved pegasussolar.com | sales@pegasussolar.com Page 1 Bill of materials Part Info Array 2 Array 1 Spares Total QTY PSR-M84 | Pegasus Rail - Mill 84"10 13 3 26 PSR-SPLS | Pegasus - Bonded Structural Splice 9 11 2 22 PSR-MCZ | Pegasus - Multi-Clamp - Mid/End 30-40mm - Black Ano 17 27 -44 PSR-SRC | Pegasus - SkipRail Clamp 7 13 -20 PSR-MLP | Pegasus - MLPE Mount 10 17 -27 PSR-LUG | Pegasus - Ground Lug 1 1 -2 PSR-WMC | Pegasus - Wire Management Clip 25 43 -68 PSR-CBG | Pegasus - Cable Grip 2 3 -5 PSR-CAP | Pegasus - End Cap 6 8 -14 PSR-DTN | Pegasus - Dovetail T-bolt and nut 19 30 -49 - | Customer Supplied R-Panel Mount 19 --19 - | Customer Supplied Mount -30 -30 BOS section MFG P/N DESCRIPTION QTY QTY w/ SPARES Longi LR5-54HABB-405M 27 27 PV MOD ENGINEERING PACKET 501 37th St Design | Bellingham Area region | Anacortes Project dashboard: 501 37th St Design | Bellingham Area region | Anacortes Produced by Kyle McOmber from Ambia on 07/02/25 © 2025 Pegasus Solar Inc. All Rights Reserved pegasussolar.com | sales@pegasussolar.com Page 4