Loading...
HomeMy WebLinkAboutBLD-2016-1518 - SOLAR PERMIT City of Anacortes Invoice/Permit#: BLD-2016-1518 904 6th Street Applied date: 08/29/2016 P.O.Box 547 Issue date: 09/27/2016 - G .; Anacortes, WA 98221-0547 Expire date: 03/28/2018 limp- - (360) 293-1901 Job Address: 1300 O AVE Permit Type: Commercial Alteration/Repair Permit ANACORTES WA98221-2187 Project: APN: P55246 Remarks: New flush roof mounted photovoltaic system. Owner: CHANDLERS SQUARE HOLDINGS, LLC Contractor: ECOTECH ENERGY SYSTEMS LLC Address: 201 NE PARK PLAZA DR Address: 814 DUPONT ST STE 105 VANCOUVER WA 98684-5874 BELLINGHAM WA 98225 Phone: Phone: (360) 318-7646 License#: ECOTEES951 RG General Information: Fees: Building Valuation 18925 Plan Review Fee 99.85 State Building Code Fee 4.50 Plan Review Deposit 99.86 Building Permit Fee 307.25 Total Calculated: 511.46 Deposits/Receipts: 0.00 Total Due: 511.46 XI -i 1 tl 7 F „ n n .. n a n THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS,!:=OR W CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORD IS COMMENCED;, HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE AND CORRECT.ALL t—R'QV Z)1yN$ OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT, THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER ST,d,TE"OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. .n SIGNATURE O OWNER ORAUTHOR[ZED AGENT ISSUED BY W• T Susie Deyo From: Tim West <tim@ecotechenergy.com> Sent: Monday, September 26, 2016 2:55 PM To: Susie Deyo Subject: Fwd: Chandler's Square Solar Attachments: Chandler's Solar Site Map - Conduit Runs and Fire Accessjpg;Chandler's Solar Explanation of Conformity to IFC Requirements.pdf ---------- Forwarded message ---------- From: "Dana Brandt" <dana cr,ecotechsolar.com> Date: Sep 26, 2016 2:53 PM Subject: Fwd: Chandler's Square Solar To: "Tim West" <tim ecotechsolar.com> Cc: ---------- Forwarded message ---------- From: Dana Brandt<danagecotechsolar.com> Date: Mon, Sep 26, 2016 at 2:26 PM Subject: Chandler's Square Solar To: Jack Kennedy<jackk a,cityofanacortes.org> Hi Jack, Let's try this again... Thanks a lot for your time on Friday-I really appreciate it.I've attached the updated site map for you with the following additions: •The larger east-facing array is moved south away from the dormer to the north •The DC conduit runs on the roof are marked in red •The access points to the east and west roofs are called out. •The location of the AC disconnects for the solar are marked on each building I've also attached the statement you requested regarding the compliance of the electrical work with the IFC and NFPA 70. Please let me know if you have any questions.Thanks again for working with me on this. Best, Dana Dana Brandt Fcotech Solar www.ecotechsolar.com danagecotechsolar.com 360.318.7646 1� Explanation of Conformity to IFC Requirements Solar Electric System 1200 & 1300 O Ave, Anacortes The solar electric systems installed at 1200 &1300 O Ave will comply with all applicable codes including IFC 605 and NFPA 70. All DC conduit runs will be labeled with the following language: "WARNING: PHOTOVOLTAIC POWER SOURCE." AC disconnects, inverters and points of interconnection will also be label according to the applicable codes. Ecotech Energy Systems, LLC DBA Ecotech Solar has obtained electrical permits 2703510E and 2703516E from Washington State Labor & Industries. The completed installation will be inspected for NFPA 70, WAC and RCW compliance by Washington State Labor & Industries. Ecotech Solar • 814 Dupont Street Bellingham,WA 98225 • www.ecotechsolar.com Dana Brandt, President • info@ecotechsolar.com • (360)318-7646 CJR Engineering Civil — Structural Engineering Comprehensive Project Management 1460215t" PL W Phone: (425) 269-5204 Lynnwood, WA 98087-6043 Fax: (425) 671-0003 August 24, 2016 City of Anacortes Building Dept. 904 6t" St. Anacortes WA 98221 11-- n� � RE: Solar PV on 1200 & 1300 O Ave v Anacortes WA 98221 Dear Sirs, Echotech Solar is proposing installing solar systems at 1200 O Ave and 1300 O Ave in Anacortes, WA(formerly Anacortes Senior Housing, now Chandler's Square Retirement Community). The solar panels have a distributed weight of 2.70 pounds per square foot (psf). I reviewed the original building structural drawings prepared by myself in 1996. The 2012 IEBC allows a 10% increase in lateral loads and a 5% increase in vertical loads before the structural system has to be re-evaluated by an engineer. According to the original drawings the roof design snow load is 30 psf; the design dead load is not listed in the drawings. The current design snow load is 25 PSF. The increase in additional dead load due to the proposed solar panels is less than the excess snow load that the roof was originally designed for, so there is no need for additional engineering calculations to re-evaluate the capacity. If anything else is required regarding this matter, please call me at (425) 269-5204, or email to clemens@cjreng.com . Sincerely, ..`�EpfGITAI S/�, J. �Oss� CJR Engineering o4y� ' �� ' �SwAs ��� a. Clemens J. Rossell, P.E. Is -T CJR Engineering Signed by: Clemens Rossell PE �ssrONALE��'1 Signature Date: 2016.08.27 11:20:36 --7 Sunmodule;// SOLARWORLD , SW 340-350 XL MONO REALVALUE TUV Power controlled: e � TUVRheinland Lowest measuring tolerance in industry , ® r Every component is tested to meet ;�® 1500 V 3 times IEC requirements J 9 NOW AVAILABLE Designed to withstand heavy accumulations of snow and ice 1000V Available with either 1000 V or 1500 V 15OOV maximum voltage rating ZS' li . 25 year linear performance warranty and 10-year product warranty iJ �i i I Glass with anti-reflective coating �® World-class quality a Ilnea IEC 67z15 5 fetyt t d IEC 67730 Cus V BlFully-automated production lines and seamless monitoring of the process and D E ,material ensure the quality that the company sets as its benchmark for its sites (((^^���� •Pedodinsp,d nEC6"°' c worldwide. ,periodlcinspection Ut.1703 •Power controlled SolarWorld Plus-Sorting Plus-Sorting guarantees highest system efficiency.SolarWorld only delivers modules on that have greater than or equal to the nameplate rated power. ❑❑ Homelnnovati Ho GREEN CERlI,.. 25-year linear performance guarantee and extension of product warranty to 10 years 0'/ °vESolarWorld guarantees a maximum performance digression of 0.7%p.a.in the courseG of 25years,a significant added value compared to the two-phase warranties common in the industry,along with our industry-first 10-year product warranty! 'in accordance with the applicable SolarWorld Limited Warranty at purchase. www.solarworld.com/warranty solarworld.com Sunmodule;.-/ SOLARWORLD SW 340-350 A MONO PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)* SW 340 SW 345 SW 350 Maximum power Pmax 340 Wp 345 Wp 350 Wp Open circuit voltage V. 47.6 V 47.9 V 48.0 V Maximum power point voltage VmPP 38.0 V 39.2 V 38.4 V Short circuit current 1,� 9.69 A 9.75 A 9.82 A Maximum power point current I-PP 9.01 A 9.10 A 9.17 A Module efficiency nm 17.04% 17.29% 17.54% `STC:1000W/m2,25'C,AM 1.5 PERFORMANCE AT 800 W/M2,NOCT,AM 1.5 SW 340 SW 345 SW 350 Maximum power Pmax 259.3 Wp 263.8 Wp 267.2 Wp Open circuit voltage V. 41.5 V 41.8 V 42.0 V Maximum power point voltage VmPP 34.9 V 35.2 V 35.4 V Short circuit current 1,� 8.05 A 8.10 A 8.16 A Maximum power point current ImPP T42 A 7.50 A 7.56 A Minor reduction in efficiency under partial load conditions at 25'C:at 200 W/W,100%ofthe STC efficiency(1000 w1W)is achieved. I,C 1000 W/W COMPONENT MATERIALS Cellspermodule 72 Front Low-iron tempered glass 800 W/M2 with ARC(EN 12150) 600 W/ma Cell type Monocrystalline Frame Clear an i�eE uminum a Cell dimensions 6.17 in x 6.17 in Weight 47.6 Ibs(21. kg) 400 W/m2 (156.75 x 156.75 m m) 200 W/aR THERMAL CHARACTERISTICS ADDITIONAL DATA 100 W/m. �§A NOCT 1 46"C Powersorting -0 Wp/+5 Wp Von TCI,, 0.042%/-C J-Box IP65 Module voltage[V] TCV 0.304%/"C Connector PV wire per UL4703 378(961) with H4/UTX connectors 4.20 0o Module fire performance (UL1703)Type 1 (106.65) 4x 1- Operating temp -40 to+95°C 11.53 .0026(6.6) (292.85) 00.35(9) PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION 15.63 - Maximum system voltage NEC 1000 V or 1500 V-Specify when ordering (397) Maximum system voltage SC if 1000 V 0 0 0.39 x 0.27 = a Maximum reverse current 25 A (lox 7)(4) ry w 15.75 Number of bypass diodes 3 (400) Design loads' Two rail system 113 psf downward,64 psf upward 0' 0 Design loads` Edge mounting 178 psf downward,23 psf upward `Please refer to the Sun module installation instructions forthe details associated with these load cases. 15.63 (397) o 00.35(9) Compatible with both"Top-Down" and"Bottom"mounting methods 15.73 (399.50) 1.30(33) •1 Grounding Locations: -4locations along the length of the 1.30(33) f. 39.4(1001) - � _L� module in the extended flange. All units provided are imperial.SI units provided in parentheses. 1.14(29) SolarWorld AG reserves the rightto make specification changes without notice. SW-01-7540US-11500V 160419 IRONRIDC3E Engineering Design Guide Roof . Mount S ste 2015 Edition v I .73 A complete guide to engineering and designing with the IronRidge XR Rail based Roof Mount System. RON RI DGE Engineering Design Guide Table of Contents This Engineering Design Guide was created to help our Engineering Data engineering partners more easily design and specify PV 12 Code Compliance roof mount applications using IronRidge components. Thermal Expansion In addition to this document,IronRidge provides a complete system of technical support including Engineering Assumptions installation guides,pre-stamped certification letters 13 AWC Lag Pull-Out Chart for most PV-friendly states,our online Design Assistant software,and live,knowledgeable person-to-person Part Sizing&Part Numers customer service. 14 Rails&Splices Clamp Size Table 15 Clamps Overview 16 Attachments 1 Introduction 17 Accessories Technical Specifications Grounding 2 Assembled Views 3 Component View Support 4 Assembly CAD Details 18 System Support Downloadable Support Documents System Parts 3rd Party Partners 5 XR Rail Design Assistant 6 Internal Splice 19 Engineering Services End Clamp Customer Service Mid Clamps Warranty 7 Adjustable L-Foot FlashFoot— 20 Warranty Information Under Clamp 8 Flush Mount Standoff Fixed Tilt Length Leg 9 Adjustable Tilt Length Leg Grounding Strap Wire Clips End Caps 10 Grounding Design Assistant 11 Summary support@ ironridge.com (800)227-9523 T.O.C. 2015 0.73 ��� IRONRIDGE Engineering Design Guide Overview Introduction IronRidge provides a comprehensive platform for designing a wide variety of photovoltaic systems for roof mounting applications.Due to its modular architecture,it can handle nearly all commercially available PV modules and layout designs.The IronRidge Roof Mount provides an all-in-one mounting solution,with the roof attachment FlashFoot,XR rails,and integrated grounding.IronRidge products are engineered to last in the most extreme weather conditions and have been installed in every continent in the world. Technical Specifications Below is a brief summary of the technical specifications of the IronRidge Roof Mount platform.More detail will be provided in the following pages.If there is additional information you require that is not listed in this Engineering Design Guide,please do not hesitate to contact us at support@ironridge.com. Allowable Roof Slope 0 to 45 Degrees Warranty 20 Year Span Lengths Up to 12' Tilt Legs Yes(10"to 40") Rail Lengths Standard&Custom Adjustable Tilt Legs Up to 45 Degrees Rail Finish Clear,Black(Only XR10&XR100) Adjustable L Feet 1-1/8"vertical adjustability Building Height Certified to 60' Splices Patent-pending internal Max Wind Speed 170 Mph(for 7-10) Stand-offs Yes(4,7") Module Orientation Landscape&Portrait Tilt Stand-offs Yes(3.75,6",9'J Wind Exposure Category B,C&D Flashing FlashFoot(All-in-One Attachment) Cantilever 40%of Maximum Span T-bolts Multiple Sizes Max Ground Snow Load 90 psf Wire Clips Black Polycarbonate Component Materials Aluminum and Stainless Steel End Caps Black Polycarbonate Hardware Stainless Steel Fasteners Engineering Support Yes(RE.Certified) support@ ironridge.com (800)227-9523 Pagel 2015 v1.73 RON RI DGE Engineering Design Guide Overview Assembled Views 1 Flush Mounted % 1 i i Y Tilt Mounted For a complete 360 degree interactive roof mounting viewing environment,go to:ironridge.com/products/roofmounting/360view. support( I ironridge.com 1 (800)227-9523 Page 2 2015 0.73 /jam IRONRIDGE Engineering Design Guide Overview XR Rails XR10 Rail XR100 Rail XR1000 Rail Internal Splices Q A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability 8'spanning capability. 12'spanning capability Self-tapping screws • Moderate load capability Heavy load capability Extreme load capability Varying versions for rails • Clear&black anod.finish • Clear&black anod.finish Clear anodized finish Grounding Straps offered Attachments FlashFoot Slotted L-Feet Standoffs Tilt Legs Anchor,flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. • Ships with all hardware High-friction serrated face Works with vent flashing • Attaches directly to rail • IBC& IRC compliant Heavy-duty profile shape Ships pre-assembled Ships with all hardware • Certified with XR Rails Clear&black anod.finish 4"and 7"Lengths Fixed and adjustable Clamps & Grounding End Clamps Mid Clamps Q Grounding Lugs Q Accessories ' 4 . Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Clear and black anod. Parallel bonding T-bolt No clips or washers Shap-in Wire Clips • Sizes from 1.22"to 2.3" Reusable up to 10 times Eliminates pre-drilling Perfected End Caps • Optional Under Clamps Mill &black stainless Easy top-slot mounting UV-protected polymer support@ I ironridge.com (800)227-9523 Page 3 2015 0.73 IRONRIDGE Engineering Design Guide Overview Assembly CAD Details Download AutoCAD File Download PDF VARIES Mid Clamp 0 W rn w w 9 A Detail A-Mid Clamp to Rail-Plan r SLOPE $"=1'-0" Typical Flush Mount Array-Plan View 1/2"=V-0" End Clamp L--Foot 0 aunm,"msranaaf E#Nng RoofSN"to" Membmnalhsulatiwf Section-Flush Mount-Flat Roof Detail B-End Clamp to Rail-Plan 3/4"=1'-0" 3"=V-0" �ReazTikt"0 6'FmMTOtleO SbeIShIMd1 Mid Clamp Solar Panel Etisfifq RwfSNxMe MembranelliuvNEvn Section-Tilt Mount-Flat Roof L-Foot 3/4"=1'-0" Mid Clamp End Clamp ' XR Rail Flashing Existing Roof Structure Detail C-Typical Roof Connection 3"=1`-0" Detail D-Mid Clamp to Rail-Elevation Detail E-End Clamp to Rail-Elev. 6"=1'-0" 6"=1'-0" VARIES C D E ifna Eustln9 RwfSWCWie I-'-VARIES EdcWq Roaf6bucWre Section-Flush Mount-Sloped Roof 3/4"=1'-0" Typical Flush Mount Array-Elevation 3/4"=1'-0" support@ I ironridge.com 1 (800)227-9523 Page 4 2015 0.73 i AO. IRONRIDGE Engineering Design Guide System Parts g g Y XR1000 Rail XR1000 is a heavyweight among solar mounting rails,built to handle extreme climates and spans 12 feet or more for commercial applications. Property Value _ Material 6000 Series Aluminum Finish Clear Anodized Beam Height 3.00" Weight/Linear Foot 0.945 Lbs j Total Cross-Sectional Area 0.807 InZ Section Modulus(X-axis) 0.530 Ina Moment of Inertia(X-axis) 0.843 In Moment of Inertia(Y-axis) 0.182 In - Torsional Constant 0.436 Ina ----- Polar Moment of Inertia 0.3299 In XR100 Rail XR100 is the ultimate residential mounting rail.It supports a range of wind and snow conditions,while also maximizing spans. Property Value - Material 6000 Series Aluminum Finish Clear&Black Anodized Beam Height 2.44" Weight/Linear Foot 0.68 Lbs Total Cross-Sectional Area 0.582 In' Section Modulus(X-axis) 0.297 Ina - _ Moment of Inertia(X-axis) 0.390 In ----------- Moment of Inertia(Y-axis) 0.085 In4 -- --- Torsional Constant 0.214 Ina Polar Moment of Inertia 0.126 In XR10 Rail XR10 is a low-profile mounting rail,perfectly matched to regions with light snow.It achieves 6 foot spans,while staying light and economical. Property Value Material 6000 Series Aluminum Finish Clear&Black Anodized - - - — Beam Height 1.75" Weight/Linear Foot 0.436 Lbs Total Cross-Sectional Area 0.363 In' -ti Section Modulus(X-axis) 0.136 Ina - _ Moment of Inertia(X-axis) 0.124In4 -------- - ""'" Moment of Inertia(Y-axis) 0.032 In4 Torsional Constant 0.076 Ina Polar Moment of Inertia 0.033 In support@ ironridge.com (800)227-9523 Page 5 2015 v1.73 IRONRIDGE Engineering Design Guide System Parts Internal Splice IronRidge Rails are easy to extend with our patent-pending Internal Splices. Property Value Material 6000 Series Aluminum Finish Mill Length 12" Hardware 2 SS Self-tapping Screws End Clamp IronRidge End Clamps secure PV modules to XR Rails using the top slot,independent upon the module's mounting holes. i" Property Value Material 5000&6000 Series Aluminum i I Finish Mill&Black Height Varies depending on Module ' Width 1.5" Depth 1.5" Weight 0.05 Lbs Hardware 1/4"-20 SS Nut and Bolt Mid Clamp IronRidge Mid Clamps secure PV modules to the rail when there are multiple modules in a row. Property Value Material 5000 Series Aluminum Finish Mill&Black Spacing between Modules 1/4" Width 1" Depth 1.5" Weight 0.05 Lbs Hardware 1/4"-20 SS Nut and Bolt Grounding Mid Clamp Grounding Mid Clamps pierce through anodized coatings to ground array,being ETL listed to UL 2703. Property Value ^` Material 304 Stainless Steel Finish Mill&Black Spacing between Modules 1/4" Width 1" Depth 1.2" Weight 0.08 Lbs Hardware 1/4"-20 SS Nut and Bolt support@ ironridge.com (800)227-9523 Page 6 2015 0.73 IRONRIDGE Engineering Design Guide System Parts Slotted L-Foot Our Slotted L-feet are engineered for most roof mounting applications.Vertical slots allow for easily dropping in rails with attached hardware and provide adjustability to account for roof irregularities. _ - Property Value NAW Material 6000 Series Aluminum Finish Mill&Black Height 3" Width 2" 3. Depth 2" Length of Vertical Slot 1.125" ---�` Weight 0.22 Lbs Hardware 3/8"SS FlashFootT" IronRidge FlashFoot'is an all-in-one solar mounting product for composition shingle roofs that eliminates the need for separate standoffs,flashings,and L-feet.FlashFoot incorporates a number of structural and waterproofing features to securely attach IronRidge Rails to roof structures,while also protecting against water intrusion and weather damage. Comes with flashing,lag bolt,and L-Foot. Property Value Material Aluminum Finish Mill&Black Height 3.5" -= Length 12" Width 12" Dual Mechanical Seal Yes Open L-Foot Slot Yes Weight 1.35 Lbs Hardware 5/16"and 3/8"SS Under Clamp IronRidge Under Clamps secure PV modules to the XR1000 Rail using the mounting holes of the PV module and the side slot of the rail. Property Value Material 6000 Series Aluminum Finish Mill } Spacing between Modules 1/a" Width 1.6" Depth 1.5" Weight 0.05 Lbs Hardware 1/4"-20 SS Nut and Bolt support@ ironridge.com (800)227-9523 Page 7 2015 v1.73 IRON RIDGE Engineering Design Guide System Parts Flush Mount Standoff Our Flush Mount Aluminum Standoffs are sized to integrate easily with Oatey Flashings.IronRidge Flush Mount Standoffs are available in 4"and 7"lengths. Standoffs include L-Foot mounting hardware.Lag bolts not included. Property Value Material(Post) 6000 Series Aluminum Material(Base) 5000 Series Aluminum Finish Mill Heights 4,7" Post Diameter 1.5" Depth 4" Weight 0.84 Lbs - Hardware 5/16" Fixed Tilt Length Leg Our Fixed Tilt Legs attach directly to IronRidge XR Rails.This simple design provides adjustability in all 3 axes,and a variety of lengths cover most angles.Each Tilt Leg Kit comes with the shorter front leg,the longer rear leg,mounting brackets and hardware. Property Value Material(Legs) 6000 Series Aluminum Material(Brackets) 5000 Series Aluminum Finish Mill Length(Short Leg) 6" Length(Long Legs) 10;15;20" Leg Diameter 1.5"Square Tube Tube Weight/Linear Foot 0.80 Lbs Height(Brackets) 2.6" Width(Brackets) 1.85" Depth(Brackets) 2" Hardware 3/8"SS support@ ironridge.com (800)227-9523 Page 8 2015 0.73 ZIALARON RIDGE Engineering Design Guide System Parts AdjustableTilt Length Leg As with our Fixed Tilt Legs,the Adjustable Tilt Legs attach directly to IronRidge XR Rails. Each Tilt Leg Assembly kit comes with the shorter fixed front leg,the longer adjustable rear leg,and all the necessary hardware. Property Value Material(Legs) 6000 Series Aluminum Material(Brackets) 5000 Series Aluminum Finish Mill . Length(Short Leg) 6" 16"Range(Long Leg) 18"—22" 28"Range(Long Leg) 30"-46" OuterTube Diameter 1.8"Square Tube InnerTube Diameter 1.5"Square Tube Upper Bracket 2.2"x4.25"x2" Lower Bracket 2.6"x1.85"x2" Hardware 3/8"SS Bonding Strap Bonding Straps are used to bond rail-to-rail connections.They are only required on the rail with the grounding lug.Bonding Strap Expansion Joint also available. A Property Value Material Tin-plated Copper Flat Braid ~' Weight 0.054 Lbs Wire Gauge 9 AWG End Caps End caps provide a finished look while protecting against the collection of water and debris inside the rail. Property Value Material Polycarbonate Color Black UV Protection Yes Wire Clips IronRidge Wire Clips snap into the top slot of XR Rails,and accommodate up to ten 5mm panel wires,or one MC4,one Enphase wire and one dual Enphase wire.The Wire Clips are molded from black polycarbonate with UV protection. Property Value Material Polycarbonate Ir Color Black UV Protection Yes . Weight 0.01 Lbs support@ ironridge.com (800)227-9523 Page 9 2015 0.73 IRONRIDGE Engineering Design Guide System Parts Microinverter Mounting Kit Mount either one or two microinverters,depending on model. Property Value A" Material Stainless Steel p Color Mill Hardware 1/4 x 3/4"H ex or T-Bolts Weight 0.06 Lbs Grounding Lug Manufactured from high strength copper alloy with stainless steel screw,UL listed and CSA certified.Hex bolt and grounding T-bolt versions available.Hex bolt version not compatible with XR10 or XR100 rails. Property Value Material SS&Tin-plated Copper Weight 0.154 Lbs !! ,a Conductor Size 4-14AWG Listing UL467 Compliant Hardware #10&1/4"SS Third-Party Grounding Components Wiley grounding clips(WEER AMC)are used in conjunction with the IronRidge Mid Clamps for grounding PV modules to rails. Property Value Material 304 Stainless Steel ETL Listed ANSI/UL 467 Compliant i Maximum Conductor Size 6 AWG(with two WEEBs contacting each module) Hardware None Wiley WEEB 6.7 grounding lugs are used in conjunction with copper wire to provide a continuous ground for every row of rails. Property Value ac: WEEB Material 304 Stainless Steel r ' \ - Lug Material Tin-plated Copper ETL Listed ANS/I UL467Compliant — -- Ground Conductor One 14 AWG to 6 AWG or two T_ 10 AWG,two 12 AWG Hardware 1/4"-20&1/4"-28 SS Wiley bonding jumpers are used to provide a continuous ground between spliced rail sections.Order one jumper for every splice. Property Value WEEB Material 304 Stainless Steel Braid Material Tin-plated Copper — ETL Listed ANSI/UL 467 Compliant Hardware 1/4"-20 SS support@ ironridge.com (800)227-9523 Page 10 2015 0.73 A��, IRON RIDGE Engineering Design Guide Design Assistant Summary With the IronRidge Design Assistant'"our customers move from laboriously designing systems across the span of weeks,to intuitively designing while pricing,a bill of materials and engineering calculations all updates in real-time. If you choose to register for an online account,you will then be able to save your work and prevent losing your project's configuration settings. The application is so quick and easy to use,multiple what-if scenarios can be evaluated through immediate engineering and pricing feedback.Engineered calculations comply with ASCE 7-10 building codes for expedited P.E.approval. The IronRidge Design Assistant"is provided free of charge to IronRidge customers. Design, engineer and quote, online, in just minutes. ironridge.com/support/designassistant a� r, support@ ironridge.com (800)227-9523 Page 11 2015 v1.73 ZA� IRQNRIDGE Engineering Design Guide Engineering Data Code Compliance IronRidge Roof Mount components,when installed in accordance with the IronRidge Roof Mount Installation Manual,will be structurally adequate and will meet the structural requirements of: •-ASCE/SEI 7-10 Min.Design Loads for Buildings&Other Structures • California Building Code 2013 Edition • AC428,Acceptance Criteria for Modular Framing Systems Used to Support PV Modules,Effective November 1,2012(ICC-ES) • Aluminum Design Manual,2010 Edition • Florida Building Code 2010 Edition • Florida Residential Building Code 2010 Edition • International Building Code 2012 Edition • International Residential Building Code 2012 Edition IronRidge Rails with Integrated Grounding conforms to: • UL Subject 2703 Outline of Investigation for Rack Mounting Systems and Clamping Devices for Flat-Plate Photovoltaic Modules and Panels • ETL Listed requirements and certification Thermal Expansion (Expansion Joints) For rows exceeding 100 feet of rail,a Grounding Strap Expansion Joint is required for thermal expansion.Insert Internal Splice into first rail and secure with screw.Assemble and secure Expansion Joint an inch from rail end.Slide second rail over Internal Splice,attach other end of Expansion Joint with hardware,and secure with screw.Torque screws and nuts to 84 in-lbs. support@ ironridge.com (800)227-9523 Page 12 2015 0.73 `/L IRONRIDGE Engineering Design Guide Engineering Data AWC Lag Pull-out Chart Lag pull-out(withdrawal)capacities(lbs)in typical roof lumber(ASD) Material Specific Gravity Lag Screw Specifications* Douglas Fir,Larch 0.50 266 Douglas Fir,South 0.46 235 Engelmann Spruce,Lodgepole Pine 0.46 235 (MSR 1650 f&higher) Hem,Fir,Redwood(close grain) 0.43 212 Hem,Fir(North) 0.46 235. Southern Pine 0.55 307 Spruce,Pine,Fir 0.42 205 Spruce Pine Fir 0.50 266 (E of 2 million psi and higher grades of MSR and MEL) Sources:American Wood Council,.NDS 2005,Table 11.2A,11.3.2A. Notes:(1)Thread mustbe embedded in theside grain ofa rafter or other structural member integral with the building structure. (2)Lag bolts must be located in the middle third of the structural member. (3)These values are not valid for wet services. (4)This table does not include shear capacities.If necessary,contact a local engineer to specify lag bolt size with regard to shear forces. (5) Install lag bolts with head and washer flush to surface(no gap).Do not over-torque. (6)Withdrawal design values for lag screw connections shall be multiplied by applicable adjustment factors if necessary. See Table 10.3.1 in the American Wood Council NDS for Wood Construction. Thread *5/16"shaft,per inch thread depth(Use flat washers with lag screws). support@ ironridge.com (800)227-9523 Page 13 2015 0.73 IRONRIDGE Engineering Design Guide Part Sizing & Part#s Rails&Splices When top mounting panels,the lengths of XR Rails required for each row may be determined by multiplying the quantity of modules in a row by the module's width.Add to this 1/4 inch space between each module and 1.5 inches to each end for the total length of rail required for that row. XR Rails Part Number Description Weight Packaging XR-1000-132A XR1000,Rail 132"(11 Feet),Clear 11.24 Lbs Sub-bundles of 4;Bundles of 80 XR-1000-168A XR1000,Rail 168"(14 Feet),Clear 14.30 Lbs Sub-bundles of 4;Bundles of 80 XR-1000-204A XR1000,Rail 204"(17 Feet),Clear 17.36 Lbs Sub-bundles of 4;Bundles of 80 XR-100-132A XR100,Rail 132"(11 Feet),Clear 7.69 Lbs Sub-bundles of 4;Bundles of 80 XR-100-132B XR100,Rail 132"(11 Feet),Black 7.69 Lbs Sub-bundles of 4,Bundles of 80 XR-100-168A XR100,Rail 168"(14 Feet),Clear 9.76 Lbs Sub-bundles of 4;Bundles of 80 XR-100-168B XR100,Rail 168"(14 Feet),Black 9.76 Lbs Sub-bundles of 4,Bundles of 80 XR-100-204A XR100,Rail 204"(17 Feet),Clear 11.88 Lbs Sub-bundles of 4,Bundles of 80 XR-100-204B XR100,Rail 204"(17 Feet),Black 11.88 Lbs Sub-bundles of 4;Bundles of 80 XR-10-132A XR10,Rail 132"(11 Feet),Clear 4.80 Lbs Sub-bundles of 4;Bundles of 160 XR-10-132B XR10,Rail 132"(11 Feet),Black 4.80 Lbs Sub-bundles of 4;Bundles of 160 XR-10-168A XR10,Rail 168"(14 Feet),Clear 6.11 Lbs Sub-bundles of 4,Bundles of 160 XR-10-168B XR10,Rail 168"(14 Feet),Black 6.11 Lbs Sub-bundles of 4;Bundles of 160 XR-10-204A XR10,Rail 204"(17 Feet),Clear 7.41 Lbs Sub-bundles of 4,Bundles of 160 XR-10-204B XR10,Rail 204"(17 Feet),Black 7.41 Lbs Sub-bundles of 4;Bundles of 160 Internal Splices Part Numer Description Weight Packaging XR-1000-SPLC XR1000 Splice 0.55 Lbs 1 Splice/Kit;20 Splices/Box XR-100-SPLC XR100 Splice 0.54 Lbs 1 Splice/Kit;20 Splices/Box XR-10-SPLC XR10 Splice 0.53 Lbs 1 Splice/Kit;20 Splices/Box Clamps Module Clamp size depends on the module thickness.Use the table below to determine which Module Clamp will fit your projects module thickness. Module Thickness Clamp Info Part Numbers Mm Inches Type End Clamp Hex Mid Clamp T-bolt Mid Clamp Grounding Mid Clamp 31.0-32.5 1.22-1.28 1 29-7000-125 29-7000-105 29-70TB-105 RS-GD-MCL-200 32.5-33.5 1.28-1.32 L 29-7000-130 29-7000-105 29-70TB-105 RS-GD-MCL-200 33.3-34.8 1.31-1.37 A 29-7000-134 29-7000-105 29-70TB-105 RS-GD-MCL-200 34.8-36.8 1.37-1.45 B 29-7000-224 29-7000-105 29-70TB-105 RS-GD-MCL-225 37.6-38.6 1.48-1.52 M 29-7000-150 29-7000-101 29-70TB-101 RS-GD-MCL-225 39.0-41.0 1.53-1.61 C 29-7000-157 29-7000-101 29-70TB-101 RS-GD-MCL-225 41.1 -42.7 1.62-1.68 J 29-7000-165 29-7000-101 29-70TB-101 RS-GD-MCL-250 42.7-44.2 1.68-1.74 E 29-7000-171 29-7000-101 29-70TB-101 RS-GD-MCL-250 45.0-47.0 1.77-1.85 F 29-7000-214 29-7000-108 29-70TB-108 RS-GD-MCL-250 46.7-48.3 1.84-1.90 K 29-7000-187 29-7000-108 29-70TB-108 RS-GD-MCL-275 49.0-51.1 1.93-2.01 G 29-7000-204 29-7000-108 29-70TB-108 RS-GD-MCL-275 57.4-58.9 2.26-2.32 H 29-7000-230 29-7000-104 29-70TB-104 Unsupported support@ ironridge.com 1 (800)227-9523 Page 14 2015 v1.73 '_. IRONRIDGE Engineering Design Guide Part Sizing& Part#s End Clamps Part Number Description Weight Packaging 29-7000-125 Kit,4pcs,End Clamp I,1.25",Mill 0.3 Lbs Kits of 4,Boxes of 25 29-7000-130 Kit,4pcs,End Clamp L,1.30,Mill 0.3 Lbs Kits of 4;Boxes of 25 29-7000-134 Kit,4pcs,End Clamp A,1.34,Mill 0.3 Lbs Kits of 4;Boxes of 25 29-7000-224 Kit,4pcs,End Clamp B,1.41;Mill 0.3 Lbs Kits of 4;Boxes of 25 29-7000-150 Kit,4pcs,End Clamp M,1.50;Mill 0.3 Lbs Kits of 4;Boxes of 25 29-7000-157 Kit,4pcs,End Clamp C,1.57",Mill 0.3 Lbs Kits of 4;Boxes of 25 29-7000-165 Kit,4pcs,End Clamp J,1.65,Mill 0.3 Lbs Kits of 4;Boxes of 25 29-7000-171 Kit,4pcs,End Clamp E,1.71';Mill 0.3 Lbs Kits of 4,Boxes of 25 29-7000-214 Kit,4pcs,End Clamp F,1.81 Mill 0.3 Lbs Kits of 4;Boxes of 25 29-7000-187 Kit,4pcs,End Clamp K,1.87,Mill 0.3 Lbs Kits of 4;Boxes of 25 29-7000-204 Kit,4pcs,End Clamp G,1.97;Mill 0.3 Lbs Kits of 4;Boxes of 25 29-7000-230 Kit,4pcs,End Clamp H,2.30,Mill 0.3 Lbs Kits of 4;Boxes of 25 29-7000-125B Kit,4pcs,End Clamp I,1.25"Black 0.3 Lbs Kits of 4;Boxes of 25 29-7000-130B Kit,4pcs,End Clamp L,1.30`;Black 0.3 Lbs Kits of 4;Boxes of 25 29-7000-134B Kit,4pcs,End Clamp A,1.34"Black 0.3 Lbs Kits of 4,Boxes of 25 29-7000-224B Kit,4pcs,End Clamp B,1.41"Black 0.3 Lbs Kits of 4;Boxes of 25 29-7000-150B Kit,4pcs,End Clamp M.1.50;Black 0.3 Lbs Kits of 4;Boxes of 25 29-7000-157B Kit,4pcs,End Clamp C,1.57"Black 0.3 Lbs Kits of 4;Boxes of 25 29-7000-165B Kit,4pcs,End Clamp J,1.65"Black 0.3 Lbs Kits of 4;Boxes of 25 29-7000-171 B Kit,4pcs,End Clamp E,1.71"Black 0.3 Lbs Kits of 4;Boxes of 25 29-7000-214B Kit,4pcs,End Clamp F.1.81"Black 0.3 Lbs Kits of 4,Boxes of 25 29-7000-187B Kit,4pcs,End Clamp K,1.87"Black 0.3 Lbs Kits of 4;Boxes of 25 29-7000-204B Kit,4pcs,End Clamp G,1.97"Black 0.3 Lbs Kits of 4,Boxes of 25 Mid Clamps Part Number Description Weight Packaging 29-7000-105 Kit,4pcs,Mid Clamp A/B/I/L,2.00;Mill(Hex) 0.3 Lbs Kits of 4,Boxes of 50 29-7000-101 Kit,4pcs,Mid Clamp C/D/J/E/M,2.25,Mill(Hex) 0.3 Lbs Kits of 4,Boxes of 50 29-7000-108 Kit,4pcs,Mid Clamp F/K/G,2.50;Mill(Hex) 0.3 Lbs Kits of 4;Boxes of 50 29-7000-104 Kit,4pcs,Mid Clamp H 2.75",Mill(Hex) 0.3 Lbs Kits of 4;Boxes of 50 29-70TB-105 Kit,4pcs,Mid Clamp A/B/I/L,2.00",Mill(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 29-70TB-101 Kit,4pcs,Mid Clamp C/D/J/E/M,2.25",Mill(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 29-70TB-108 Kit,4pcs,Mid Clamp F/K/G,2.50",Mill(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 29-70TB-104 Kit,4pcs,Mid Clamp H,2.75,Mill(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 29-7000-105B Kit,4pcs,Mid Clamp A/B/I/L,2.0;Black(Hex) 0.3 Lbs Kits of 4;Boxes of 50 29-7000-101 B Kit,4pcs,Mid Clamp C/D/J/E/M,2.25;Black(Hex) 0.3 Lbs Kits of 4;Boxes of 50 29-7000-108B Kit,4pcs,Mid Clamp F/K/G,2.5,Black(Hex) 0.3 Lbs Kits of 4;Boxes of 50 29-7000-104B Kit,4pcs,Mid Clamp H,2.75",Black(Hex) 0.3 Lbs Kits of 4;Boxes of 50 29-70TB-105B Kit,4pcs,Mid Clamp A/B/I/L,2.00",lack(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 29-70TB-101 B Kit,4pcs,Mid Clamp C/D/J/E/M,2.25;.Black(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 29-70TB-108B Kit,4pcs,Mid Clamp F/K/G,2.50,Black(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 29-70TB-104B Kit,4pcs,Mid Clamp H,2.75;Black(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 support@ I ironridge.com 1 (800)227-9523 Page 15 2015 v1.73 IRONRIDGE Engineering Design Guide Part Sizing & Part#s Grounding Mid Clamps Part Number Description Weight Packaging RS-GD-MCL-200 Kit,4pcs,Mid Clamp A/B/I/L,2.00"Mill(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 RS-GD-MCL-225 Kit,4pcs,Mid Clamp C/D/J/EM,2.25;Mill(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 RS-GD-MCL-250 Kit,4pcs,Mid Clamp F/K/G,2.50,Mill(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 RS-GD-MCL-275 Kit,4pcs,Mid Clamp H 2.75,Mill(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 RS-GD-MCL-200B Kit,4pcs,Mid Clamp A/B/I/L,2.00,Black(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 RS-GD-MCL-225B Kit,4pcs,Mid Clamp C/D/J/E/M,2.25,Black(T bolt) 0.3 Lbs Kits of 4,Boxes of 50 RS-GD-MCL-250B Kit,4pcs,Mid Clamp F/K/G,2.50",Black(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 RS-GD-MCL-275B Kit,4pcs,Mid Clamp H,2.75 Black(T-bolt) 0.3 Lbs Kits of 4;Boxes of 50 Under Clamps Part Number Description Weight Packaging 29-7000-117 Kit,4pcs,Under Clamp 0.4 Lbs Kits of 4;Boxes of 25 Attachments Slotted L-Feet Part Number Description Weight Packaging RS-LFT-001 4-pack,Slotted L-Foot,Mill 1.14 Lbs 4 L-feet/Pack;25 Kits/Box RS-LF17-001 B 4-pack,Slotted L-Foot,Black 1.14 Lbs 4 L-feet/Pack;25 Kits/Box FlashFoot- Part Number Description Weight Packaging RF-FLSH-001 Kit,6-pack,IronRidge FlashFoot(Mill)(L-foot Included) 8.1 Lbs 6 Flashings/Box RF-FLSH-001 B Kit,6-pack,IronRidge FlashFoot(Black)(L-foot Included) 8.1 Lbs 6 Flashings/Box Flush Mount Standoffs Part Number Description Weight Packaging 51-6004-500L Kit,4"Standoff,Flush Mount,Mill 0.56 Lbs 20 Standoffs/Box 51-6007-500L Kit,7"Standoff,Flush Mount,Mill 0.84 Lbs 20 Standoffs/Box support@ ironridge.com (800)227-9523 Page 16 2015 v1.73 . IRONRIDGE Engineering Design Guide Part Sizing & Part #s AdjustableTilt Legs Part Number Description Weight Packaging 51-7516-016H AdjustableTilt Leg,16 inches(18-22") 4.29 Lbs 12 AdjustableTilt Legs/Box 51-7528-028H AdjustableTilt Leg,28 inches(30-46") 6.34 Lbs 12 AdjustableTilt Legs/Box Fixed Tilt Legs Part Number Description Weight Packaging 51-7210-010 Tilt Leg Kit,10',Mill 1.87 Lbs 20 Fixed Tilt Legs/Box 51-7215-015 Tilt Leg Kit,15",Mill 2.20 Lbs 20 Fixed Tilt Legs/Box 51-7220-020 Tilt Leg Kit,20",Mill 2.56 Lbs 20 Fixed Tilt Legs/Box Accessories Part Number Description Weight Packaging XR-1000-CAP XR1000 End Cap(Polybag,20) 7 Lbs/Box 20 End Caps/Bag;500 Caps/Box XR-100-CAP XR100 End Cap(Polybag,20) 5 Lbs/Box 20 End Caps/Bag;500 Caps/Box XR-10-CAP XR10 End Cap(Polybag,20) 4 Lbs/Box 20 End Caps/Bag;500 Caps/Box 29-4000-077 Wire Clip(Polybag,20) 6.70 Lbs/Box 20 Clips/Bag;500 Clips/Box 29-5003-005 Kit,1/4 x 3/4 Microinverter Mounting 10.30 Lbs/Box 150 Kits/Box 29-50TB-005 Kit,1/4 x 3/4 Microinverter Mounting,T-Bolt 10.30 Lbs/Box 150 Kits/Box Grounding Part Number Description Weight Packaging RS-GDST-001 Bonding Strap 2.7 Lbs/Box 50 Kits/Box RS-GDXP-001 Bonding Strap Expansion Joint 2.0 Lbs/Box 25 Kits/Box RS-GDLG-001 Grounding Lug(XR7000 Compatible Only) 7.7 Lbs/Box 50 Kits/Box RS-GDLG-002 Grounding Lug(T-Bolt) 7.9 Lbs/Box 50 Kits/Box 29-4000-001 WEEB DMC Compression Clip .50 Lbs/Box 100 Clips/Box 29-4000-002 WEEB Grounding Lug 6.7 12.45 Lbs/Box 100 Lugs /Box 29-4000-003 WEEB Bonding Jumper 17.55 Lbs/Box 100 Jumpers/Box support@ ironridge.com (800)227-9523 Page 17 2015 v1.73 `/ L IRONRIDGE Engineering Design Guide Support System Support IronRidge provides a complete system of technical support including installation guides,pre-stamped certification letters for most PV-friendly states,our online Design Assistant software,and live,knowledgeable person-to-person customer service. Downloadable Support Documents Our website at www.ironridge.com/products/roofmounting/systemsupport contains all of the technical support information necessary to design,quote,certify,and install an IronRidge Roof Mount system.The specific documents that can be found here include: • CAD files(AutoCAD format) • Engineering Design Guide • Pre-stamped Certification Letters • Installation Guides • Parts Catalog 3rd Party Partners We've engineered best-of-class 3rd party solutions with our Roof Mount platform to further improve the quality we offer customers. Where appropriate,pre-stamped certification letters are included to simplify and expedite the design,quoting,and permitting processes.At this time,we work with roofing products from the following companies: • Ecofasten • Enphase Quick Mount PV • S5! • Wiley Design Assistant The IronRidge Design Assistant automates much of the Design and Engineering phases of a project.Easily accessible from our website, the Design Assistant provides a highly intuitive layout interface,automatically calculates critical engineering information based on your project's specific load conditions,provides the ability to add optional components and 3rd party products,and determines an accurate bill of materials and quotations. The Roof Mount Design Assistant can be accessed at:www.ironridge.com/rm support@ ironridge.com (800)227-9523 Page 18 2015 v1.73 AM& IRONRIDGE Engineering Design Guide Support Engineering Services IronRidge provides expedited site specific certification letters for many standard load conditions.These letters are available in most PV-friendly states,including: Arizona North Carolina California New Hampshire Colorado New Jersey Connecticut New Mexico D.C. Nevada Delaware New York Florida Ohio Georgia Oklahoma Hawaii Oregon Iowa Pennsylvania Illinois Rhode Island Indiana South Carolina Louisiana Tennessee Massachusetts Texas Maryland Utah Michigan Virginia Maine Vermont Minnesota Washington Missouri In addition,we provide pre-stamped certification letters for: Ontario New Zealand Puerto Rico For non-standard certifications,wet-stamped letters,or specialized engineering requests,please contact support0ronridge.com. Customer Service The IronRidge support staff is knowledgeable,experienced,friendly,and responsive.We would be happy to provide assistance on any questions you may have.Please feel free to contact us through your preferred method at: Email:supportPironridge.com Phone:800-227-9523 support@ ironridge.com (800)227-9523 Page 19 2015 v1.73 IRONRIDGE Engineering Design Guide Warranty Warranty Information Effective for IronRidge,Inc.("IronRidge")mounting structure components("Products")manufactured after April 1 st,2012,IronRidge provides the following warranties,for Products installed properly and used for the purpose for which the Products are designed: • finishes shall be free of visible defects,peeling,or cracking,under normal atmospheric conditions,for a period of three(3)years from the earlier of(i)the date of complete installation of the Product or(ii)thirty days after the original purchaser's date of purchase of the Product("Finish Warranty'; • components shall be free of structurally-related defects in materials for a period of ten(10)years from the earlier of(i) the date of complete installation of the Product or(ii)thirty days after the original purchaser's date of purchase of the Product; • components shall be free of functionally-related manufacturing defects for a period of twenty(20)years from date of manufacture. The Finish Warranty does not apply to:(a)surface oxidation of the galvanized steel components or any foreign residue deposited on Product finish;and(b)Products installed in corrosive atmospheric conditions,as defined solely by IronRidge;corrosive atmospheric conditions include,but are not limited to,conditions where Product is exposed to corrosive chemicals,fumes,cement dust,salt water marine environments or to continual spraying of either salt or fresh water.The Finish Warranty is VOID if(c)the practices specified by AAMA 609&610-02—"Cleaning and Maintenance for Architecturally Finished Aluminum"(www.aamanet.org)are not followed by Pur- chaser for IronRidge's aluminum based components;and(d)if the practices specified by ASTM A780/A780M-09"Standard Practice for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized Coatings"are not followed by Purchaser for IronRidge's galvanized steel-based components. The warranties above do not cover any parts or materials not manufactured by IronRidge,and exclude non-functionally-related de- fects,as defined solely by IronRidge.The warranties do not cover any defect that has not been reported to IronRidge in writing within twenty(20)days after discovery of such defect. In the event of breach of or non-compliance.with the warranties set forth above,IronRidge's sole obligation and liability,and the sole and exclusive remedy for such breach or non-compliance,shall be correction of defects by repair,replacement,or credit,at IronRidge's sole discretion. Such repair,replacement or credit shall completely satisfy and discharge all of IronRidge's liability with respect to these warranties. Refurbished Product may be used to repair or replace the defective components.Transportation,installation,labor,or any other costs associated with Product replacement are not covered by these warranties and are not reimbursable.These warranties additionally do not cover(a)normal wear,or damage resulting from misuse,overloading,abuse,improper installation(including failure to follow pro- fessional instruction and certification),negligence,or accident,or from force majeure acts including any natural disasters,war or crimi- nal acts;and(b)Products that have been altered,modified or"repaired without written authorization from IronRidge or its authorized representative;and(c)Products used in a manner or for a purpose other than that specified by IronRidge.A formal document proving the purchase and the purchase date of the Product is required with any warranty claim. Except as set forth above,IronRidge sells the Products on an"AS IS"basis,which may not be free of errors or defects,and ALL EXPRESS OR IMPLIED REPRESENTATIONS AND WARRANTIES,INCLUDING ANY WARRANTIES OF MERCHANTABILITY,FITNESS FOR A PARTICULAR PURPOSE,QUALITY,WORKMANLIKE EFFORT,CORRESPONDENCE TO DESCRIPTION,DESIGN,TITLE OR NON-INFRINGEMENT,OR ARISING FROM COURSE OF DEALING,COURSE OF PERFORMANCE ORTRADE PRACTICE,ARE HEREBY DISCLAIMED. support@ ironridge.com (800)227-9523 Page 20 2015 v1.73 D s f I _ a Rom' i � i r i pr A li�o CL U. � v AD 41, M I C. CL al. 9 I? tT a CO Ll: co n -- iOle f ( _ „ , Ij - tl . l w - - : IF i rvjm e ------------ JOEL— MR wk � 1r i I , -} e : - - :