REPORT OF FIELD INSPECTION
CLIENT: Mark E. Christ Architects M.T.C.PROJECT#: 09BO56-01 Report#F 26504
ATTN: Mark Christ DATE: February 5,2010
Chandler Square
ADDRESS: 810 Bennett Street PROJECT: Independent Expansion
Sedro Woolley,WA 98284 PROJECT ADDRESS:
STRUCT. ENGINEER:
CIVIL ENGINEER:
ARCHITECT: Mark E.Christ Architects
CONTRACTOR: Exxel Pacific
PERMIT NO.:
Inspection Performed: VSI Time Onsite: 8:00 Temp:
Any Deficiencies Noted: ❑ Need Engineer's Approval ❑ Other ❑
MTC on site as requested by client to verify stability of footing subgrade for added basement south of building
Footings were excavated down to native blue silty sand to sandy silt Subgrade is considered firm and stable with less
than 1" T-probe penetration, and to the best of my knowledge, subgrade is stable for continued construction
REPORTED BY: K. Walters, Soils Technician se REVIEWED BY: Brian Steele, L.E.G.
DISTRIBUTION: original:client cc: tjm(aexxelpacific.com cc: caseyd(@,,exxelpaciftc.com
cc:scimitardave a gmai1.com cc:john(@,semreu.com cc:
All results apply only to actual locations and materials tested.As a mutual protection to cliems.the public aad our ithes,all reports are sobmitted as the confidential property of clients.and amhorization for publication of statements,conclusions or extracts train or
regarding our reports is reserved pending our winen approval.C)2008 -2010 Materials Testing$ Consulting, Inc. All rights reserved.
Corporate • 777 Chrysler Drive • Burlington,WA 98233 o Phone 360.755.1990 • Fax 360.755.1980
SW Region • 2118 Black Lake Blvd. S.W. • Olympia,WA 98512 • Phone 360.534.9777 • Fax 360.534.9779
NW Region • 2126 East Bakerview Road,Suite#101 o Bellingham,WA 98226 • Phone 360.647.6061 • Fax 360.647.8111
Website Address:www.mtc-inc.net Rev 07/07
MTV Materials Testing & Consulting, Inc.
Remember... One test is worth a thousand expert opinions
,c„-�Iw� Geotechnical Engineering - Special Inspection- Materials Testing
REPORT OF FIELD INSPECTION
Report 4F 27460
CLIENT: Mark E.Christ Architects M.T.C.PROJECT#: 09BO56-01
ATTN: Mark Christ DATE: March 2,2010
Chandler Square
ADDRESS: 810 Bennett Street PROJECT: Independent Expansion
Sedro Woolley,WA 98284 PROJECT ADDRESS:
STRUCT. ENGINEER:
CIVIL ENGINEER:
ARCHITECT: Mark E.Christ Architects
CONTRACTOR: Exxel Pacific
PERMIT NO.:
Inspection Performed: VSI Time Onsite: 8:00 Temp:
Any Deficiencies Noted: ❑ Need Engineer's Approval ❑ Other ❑
MTC on site as requested by client to verify stability of footing subgrade for dining room addition south of existing
dining room. Contractor excavated sand to sandy silt with occasional gravel. Subgrade was undisturbed native soils with
<1" T-probe penetation. Subgarde is considered to be firm and stable to the best of my knowledge.
i
l
REPORTED BY: K. Walters, Soils Technician se REVIEWED BY: Brian Steele,L.E.G.
DISTRIBUTION: original:client cc: tjm@exxelpacific.com cc: caseyd a,exxelpacific.com
cc:scimitardave@gmail.com cc:johnna semreu.com cc:
All results apply only to actual locations and materials tested.As a annual protection to clients,the public and ourselves,all reports are submitted as the confidential property of clients,and authorustion for publication of statements,conclusions or extracts Iran or
regarding our reports is reserved pending oa wnnea appraaL 2008 - 2010 Materials Testing&.Consulting, Inc. All rights reserved.
Corporate - 777 Chrysler Drive - Burlington,WA 98233 - Phone 360.755.1990 - Fax 360.755.1980
SW Region is 2118 Black Lake Blvd.S.W. - Olympia,WA 98512 - Phone 360.534.9777 - Fax 360.534.9779
NW Region - 2126 East Bakerview Road,Suite#101 - Bellingham,WA 98226 - Phone 360.647.6061 - Fax 360.647.8111
Website Address:www.mtc-inc.net Rev.07/07
i
Materials Testing & Consulting, Inc.
Remember... One test is worth a thousand expert opinions
Geotechnical Engineering• Special Inspection • Materials Testing
REPORT OF FIELD INSPECTION
Report#F 25970
CLIENT: Mark E. Christ Architects M.T.C.PROJECT#: 09BO56-01
ATTN: Mark Christ DATE: November 3,2009
Chandler Square
ADDRESS: 810 Bennett Street PROJECT: Independent Expansion
Sedro Woolley,WA 98284 PROJECT ADDRESS:
STRUCT. ENGINEER:
CIVIL ENGINEER:
ARCHITECT: Mark E. Christ Architects
CONTRACTOR: Exxel Pacific
PERMIT NO.:
Inspection Performed: VSI Time Onsite: —9AM Temp: —48 F
Any Deficiencies Noted: ® Need Engineer's Approval ❑ Other ❑
MTC onsite at clients request to observe and test compaction of imported gravel placed on the east edge of the building
pad where the removal of unsuitable native fill soils(see MTC report#F24878)exposed undisturbed native glacial till
soils consisting of sandy silt with some gravel that is dense based on minimal penetration with a 5/8" round tip T-probe.
The imported gravel that was brought to the site contained excess moisture and the first 12"thick lift while displaying
suitable densities(between 140-145 PCF),deflected underfoot and beneath construction traffic.
MTC recommends aerating the imported gravel until moisture conditioned to within 3% of optimal wind rows
or scarified stockpiles,covered during wet weather,would be ideal for conditioning. Once conditioned the imported
gravel should be mechanically compacted to 95%per the MDD, and assessed by MTC,Inc.
In additional, MTC examined all perimeter footing sub grades west of gridline 6.5. Minimal to no penetration with a
5/8 roundtip T-probe was observed in a grey sandy silt with trace gravel. This is in agreement with the project
geotechnical report and is suitable for footing sub grade.
REPORTED BY: A. Wiser, Geologist sc REVIEWED BY: Brian Steele, L.E.G.
DISTRIBUTION: original:client cc: tjm@exxelpacific.com cc: caseyd@aexxelpacific.com
cc:scimitardave(a gmail.com cc:john(a semreu.com cc:
All results apply only to actual locations and materials tested.As a mutual protection to clients,the public and ourselves,all reports are submitted as the confidential property of clients,and authorivatioa for publication of statements,conclusions or a tmcts from or
regarding our reports is reserved pending om written approval.®2008 - 2009 Materials Testing&Consulting. Inc. All rights reserved.
Corporate • 777 Chrysler Drive • Burlington,WA 98233 • Phone 360.755.1990 • Fax 360.755.1980
SW Region • 2118 Black Lake Blvd.S.W. 9 Olympia,WA 98512 • Phone 360.534.9777 • Fax 360.534.9779
NW Region • 2126 East Bakerview Road,Suite#101 9 Bellingham,WA 98226 • Phone 360.647.6061 9 Fax 360.647.8111
Website Address:www.mtc-inc.net Rev.07/07
2 3 a t+ T
V � �-, D �
O N X �-al
C COt0 dh
M O n
00 'Wo I 4d
7. 4 Q 24" a 0 °
0 00
o rn 0)5. °
:3x x
c+ Cl) CDI 0) 0)
O rn �.c
O D o o.
n p �p 0
o 0
3 Wo3
3 II
3 � cn x x 1
co
O 0) rn w
c� p,
CD Q
N W C
w a
.p
Q o r. a rn rn
3 o T x x
Q D>
Q o `° 7'-0'
_ W
oO r.o a O O X 4 O
T am 0)
e+ 14
ao O — t
3 0
D T 0 II
aT
n �
O Dv 0 II
0 {,^y3 N
0 3
CD It-
O y 3 II
�0Ish T O
D O W aF *0 00
Q o0
D NO
3 co w
W ► _
o f
<
m
� p T coco
CD
A
CP
0 CUC 0
o o f seat G/A14 .. 0'
o 0