Loading...
HomeMy WebLinkAboutCOR-2010-Espanded Scope of Work - MARK CHRIST, ARCHITECT 810 Bennett Street Sedro-Woolley, WA 98284 mark@markchrist.com DATE ^ JOB NO. 7 /0 (360) 855-1546 Fax (360) 855-1546 ATTENTION TO I RE: �-u o !�r¢Cd� i WE ARE SENDING YOU ❑ Attached ❑ Under separate cover via the following items: ❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples ❑ Specifications ❑ Copy of letter ❑ Change order 0 97_IVf C&V COPIES DATE NO. DESCRIPTION Z D i THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ Approved as submitted ❑ Resubmit copies for approval ❑ For your use ❑ Approved as noted ❑ Submit copies for distribution ❑ As requested ❑ Returned for corrections ❑ Return corrected prints ❑ For review and comment ❑ FORBIDS DUE ❑ PRINTS RETURNED AFTER LOAN TO US REMARKS i Ol�7 v CT—�TLC.a.c A., G 1 v [ . v..�0 r.A `fL , �i!_' k fZ �s o ✓� t �tr eo 2 � h Gr.� y 1(�G%,ru.G✓� � /G�-Lc�� � lGr d��c.��l t4 COPY TO� rLP' SIGNED: if enclosures are not as noted,kindly notify us at once. Residential Mark E. Christ Commercial > t (- n� tr Institutional Architect F t:: n(�',rll's'` ' New Construction Cp qr ?]R Addition 0Tt1 E 01F t?. `L.Hi 13,Tt '6 Renovation (360) 855-1546 ,� ,�,,,�„„, Remodel Programming 810 Bennett Street Design Documentation Sedro-Woolley, WA 98284 Administration markchrist.com Richard Swanson 05/17/10 Washington State Department of Health Construction Review Services 310 Israel Road SE Olympia, WA 98501 RE: Chandler's Square CRS#60112372 Dear Richard, Enclosed please find sheet A23 documenting an expanded scope of work the Owner wishes to add to this project. Attached please fin the following supporting documents: 1. Chandler's Square Infection Control Procedures dated 5/15/10 • The Kitchen Air conditioning is to be installed during Kitchen off-hours • The Dining Room ceiling tile is to be installed during Dining Room off-hours 2. Kitchen Air Conditioning Product Literature 3. Convection Steamer and Range Product Literature 4. Sheet Vinyl Flooring Product Literature 5. Ceiling Tile Product Literature The flowing is a breakdown of the anticipated added cost to the project: Kitchen Air Conditioning: $ 6,500 Convection Steamer and Range: $ 13,108 Sheet Vinyl Flooring: $ 8,219 Ceiling Tile: $ 13,023 As always, should you have any questions concerning any of the above information please contact me. Thank you for your review of our project. W L/ I Mark Christ I of 1 �a A Retirement Community so 15 May 2010 To Whom It may concern: This memo covers the delivery of food to our 25 Assisted Living Residents during the times when the kitchen is anticipated to be unavailable due to the installation of a new kitchen floor. We anticipate completing the flooring above will take a total four days. The tentative plan is to begin the remodel Sunday night,after dinner,so affected meals would be B/L/D Monday through Thursday. All kitchen equipment would be stored in our Compass Room,leaving the Dining Room available for catered dining. Juice and Coffee Machines will not be affected,but limited to recyclable paper cups. Although we anticipate access to both the refrigerator and freezer during this time,there is a plan to install three(on-site)residential refrigerators in the Dining room to assist with breakfasts. Breakfast would consist of Muffins, Fruit,and Cold Cereal. All serving items will be disposable. Lunches and Dinners would be fully catered by local businesses,again all using fully disposable utensils and serving dishes.Fruit(apples and bananas)will be provided 24/7. Sin r , Pete Kovach Director 1.300 `O'Avenue _ Phone 360.29.3-1300 Anacortes, WA 98221 F:&x 360-2.93-3923 AANTSUBISHI k ELECTRIC WIL11M. HVAC Advanced Products Divislon split-ductlessA/C and Heat Pumps � ' • f ' .r. • • • • • Job Name: Location: Date: Purchaser: Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction Unit Designation: Schedule No.: GENERAL FEATURES f •Catechin and anti-allergy enzyme fitters for high air-purification ti ° capabilites •Updated sleek,compact indoor unit design 1 Indoor Unit MSY-D36NA •Remote-controlled wide airflow enables ideal horizontal air ti distribution $ •Self-check function—onboard diagnostics •Advanced microprocessor control •Auto restart following a power outage wi • reless Remote Controller Outdoor Unit MUY-D36NA Wireless remote controller •Limited warranty:five years on parts and defects and seven Indoor Unit years on compressors MCA. ......... ............. .. ......... ... .......... 1 A FanMotor .. ................ ...... ............0.76 F.L.A. OPTIONAL ACCESSORIES Airflow Outdoor Unit Cooling(Lo-Med-Hi)........ ... ...389-639-848 Dry CFM 350-576-763 Wet CFM •Drain Socket Assembly(MAC-811DS) Sound Pressure Level Indoor Unit Cooling(Lo-Med-Hi)........ ... .. .... ...32 - 42-49 dB(A) •Three-pole Disconnect Switch(TAZ-MS303) •M-NET Control Adapter(MAC-3991F) DIMENSIONS UNIT INCHES/MM •MA Contact Terminal Interface(MAC-3971F) W 46-1/1611,170 •Wired Remote Controller(PAR-21 MAA;Requires MAC-3971) D 11-5/8/295 •Centralized On/Off Remote Controller(MAC-821 SC; Up to H El 14-3/8/365 eight units, requires one MAC-3971F per indoor unit) Weight .......... ..... .. .... ... .. .. .. ..... .40 lbs. / 18 kg •Condensate Pump(230V;S13100-230) External Finish ..... ... . . .. .. . . ... .Munsell No.1.OY 9.2/0.2 •Anti-allergy Enzyme Filter(Two pieces per set;MAC-1415FT) Field Drainpipe Size O.D................ .. ... . 5/8"/15.88 mm Remote Controller .. .......... .. .... ....... .......Wireless (Optional Wired Remote Controller PAR-21MAA Cooling' see Data Submittal Sheet) Rated Capacity............... ........... ... ..34.600 Btu/h Minimum Capacity .......... ...................9,800 Btu/h SEER ... .. ..... .. ....... ............... ....15.1 Btu/h1W Outdoor Unit Total Input............... .......................4.240 W `Rating Conditions(Cooing)-Indoor 80°F(27•C)DB,67°F(19°C)WB;Outdoor 95°F Compressor ...... .. ....... . . . . . . . DC Inverter-driven Rotary (35°C)DB.75-F(24°C)WB- MCA. .. ....... .... ....... ....... .... .. ... ...... ... 21 A Fan Motor...... ......... ....... ........... .... 0.93 F.L.A. Power Supply.... .... ..... .. .....208/23OV,1-Phase,60 Hz Sound Pressure Level Breaker Size...... ..... ............... ..............25 A Cooling 56 dB(A) Voltage DIMENSIONS INCHES/MM Indoor-Outdoor S1-S2 ....... .. ....... ......AC 208/230V W 33-1/16/840 Indoor-Outdoor S2-S3 .. ....... .. ..... ...... ...DC 12-24V D 13 1330 Indoor-Remote Controller...... ......... ..... .....Wireless H 33-7/16!849 OPERATING RANGE Indoor Intake Air Temp. Outdoor Intake Air Temp. Weight . ....... .. .. ... .. ....... ...... . .. ..126 lbs. / 57 kg 90°F(32°C)DB, External Finish... ......... ... . . . . . ..Munsell No.3Y 7.8/1.1 Maximum 73°F(23•C)WB 115°F(as°c)Dl3 Refrigerant Type........... ...... ..... ....... ...... R410A Cooling 67°F(19°C)DB. Refrigerant Pipe Size O.D. Minimum 57°F(14°C)WB 14°F(-10°C)DB Gas Side ... .... ..... ....................5/8"/15.88 mm Liquid Side.. .... .. ..... .. .. ....... ........ 3/8"/9.53 mm Max.Refrigerant Pipe Length.... ....... ...... ....100' / 30 m Max.Refrigerant Pipe Height Difference .............50' 1 15 m Connection Method ....... .. ..... .. .. ... .. .. ........Flared , i� 1 NVfR�R r i • i i MSY-D36NA 45-1/2 Unit: inch 2-11116 Indoor unit 411116 46-1/16 Jr 2-3Ii6 20-718 17-11M6 5-318 P-- 11-5/8 1/! Wall hde a3 Air in Installatim plate 2-5/16 Piping 2-1-16 33-11115 9-W ■ Wrceless remote controller Required Space(indoor Unit) - - Drain hose 4n a nn Air OUi s7/s m a c Piping IrnstAatiort Liquid In, ONig-11116 0-1/40.11 (Flared canneckn e318) a91161D 4an veue mme. Gas line o016.718 e1.151160.6 (Joint connection 11518J a1-114 I.n a Jnnt go of-1 160.11 a For lek-left,back:or left, (Flared connection 618) et-1141.D. bottom piping(using spacer):5-1/8 or more Drain hosel Insulatim of-118 Connected pan t19N6 0.Et MUY-D36NA Unit:inch REQUIRED SPACE open as rule 20 inch or more if I the front and both sides are open finis!riles tl-25r]t t-9i16 4 inch or more! V 8 inch or more if there are obstades to both sides fins la � 4''el��e a Air ut 1-s/1311/16 slat l9-L V 16 P 9-9ilfi Open as a rule _,?-vim 20 inch or more If the back, both sides and top are open O �T .a iuuuu a+ :sn AwtMITSUBISHI ELECTRIC HVAC Advanced Products Division 3400 Lawrenceville Suwanee Rd Suwanee.GA 30024 NONE ma n(k� V ® Tele:678-376-2900•Fax:800-889-9904 Toll Free:800-433-4822(#3) www.mehvac.com C SD-MSY-D36NA/MUY-D36NA-200909 C MITSUBISHI ELECTRIC/HVAC 2009 Specifications are subject to change without notice. q� Project /Cleveland 'te-m Quantity FCSI Section HIGH EFFICIENCY BOILERLESS Approval STEAMCHEFTM CONVECTION STEAMERS Date SteamChef rM 6 MODEL: 0 22CEr6.1 h`eamsa`F Boilerless Convection Steamer, T-h-1 gy Automatic Water Fill&Drain, BY Cleveland 13.5 kW Boiler-Free Counter Type Design I Cleveland Standard Features ■ Cooking capacity for up to six 12"x 20"x 2.5"deep steam table pans(1/1 GIN,65 mm). u ■ High-speed electric convection steamer with open style 1.5 gallon water reservoir located at the bottom of the cooking compartment r for easy access and maintenance. _ ■ Fan forced convection steam with patented KleanShield I cooking compartment design.KleanShieldTM collects and removes condensate waste from the cooking compartment.This keeps the compartment clean,safe from impurities and easy to maintain. Eliminates foaming and avoids contamination of the reservoir water. ■ Automatic water level controls,fills when main power switch is turned ON,Low Water and High Water probes inside cooking compartment maintains water levels during cooking,eliminating the need to manually refill and monitor water level during cooking. Additional Safety Overflow Standpipe.193`preheat and standby •� temperature.High Temperature Safety Shut-off. ■ Steam and Fan Shut Off Control when compartment door is opened. ■ 13.5 kW electric heating elements are in aluminum blocks for fast Short Form Specifications and ultra efficient heat transfer.Elements never need deliming because they are not immersed in water. Shall be a Cleveland SteamChef"m 6,model 22CET6.1,one compartment ■ Exclusive SureCook Compartment Controls improves cooking high-speed electric convection steamer. _ volt, _phase. Standard speed and accuracy.New energy saving design reduces water and with SureCook Compartment Controls,60-minute electro-mechanical timer electric usage.On-demand New energy control for faster heat u and with load compensating feature.Capacity for six 2.5'(1/1 GIN,65 mm)full 9e• Po P size steam table pans. 13.5 kW electric heating elements in aluminum recovery.Energy saving Standby Feature when not in use.The blocks.Includes 1/2'ball valve style automatic drain.Automatic water level SureCook timer automatically adjusts the cooking time with the controls. Heavy-duty 14 gauge stainless steel cooking compartment door volume of product being cooked,eliminating guesswork on when and latch.KleanSh/eW clean cavity protection.4'Adjustable Legs the product is finished.Includes a 60-Minute Electro-Mechanical Timer,LED Indicator Lights for SureCook Cycle, Power On and Reset.Timed and Manual Bypass Switch for constant steaming. ■ Exclusive SteamChefTm Automatic Drain Control.Generator Drains Options&ACCeMdes when main power is turned OFF via 1/2"ball valve with micro switch circuitry.Simple 1 1/4"NPT drain connection required with water O 34'(864mm)High Stainless Steel Economy Stand,for one 22CET6.1 saving cold water condenser and 3 minute rinse feature. (UniStand34) ■ Left Hand Door Hinging:Compartment Doors hinged on the left, Q 44'(1118mm)High Stainless Steel Stacking Stand(ES263044),for 9 g Pa 9� mounting two stacked 22CET6.1 controls on the right. O Right Hand Door Hinging, g g ng,controls on right(DHR) ■ Exclusive,durable 14 gauge stainless steel compartment door and O ON/OFF Compartment control only,no timer(MC) latch withstands abuse and heavy wear.Two piece compartment O 5 Foot(1524mm)FDA Approved National Hose Thread style door with tree floating inner door is self adjustable and prevents water connection kit(garden hose thread),2 required leaks.Reversible door gasket doubles the life of the gasket. (NHT60) ■ Heavy-duty 4"(102mm)Skid Resistant Adjustable Legs with D Single Point Water Connection(SPW) Flanged Feet. O Optional Voltages,480 Volt(VOS2),see back for ■ Meets agency codes:specifically UL and CUL listed,classified to alternative voltages. SECT.B PAGE 3 NSF#4 and Energy Star. 0609 1333 East 179 St, Tel:1-216-481-4900 Web Site:www.ClevelandRange.com Cleveland,Ohio,U.S.A.44110 Fax:1-216-481-3782 Email:Steam@ClevelandRange.com Canttowoc • Each compartment has capacity for:Six,12"x 20"x 2Y2"deep Cafeteria Pans. COLD WATER • Each compartment has capacity for:Twelve,12"x 20"x 1"deep Cafeteria Pans. C-1:Feed water for reservoir,35 Psi Minimum,60 Psi Maximum. • Each compartment has capacity for:Four,12-x 20-x 4-deep Cafeteria Pans. C-2:Drain condenser water,35 Psi Minimum,60 Psi Maximum. Two 3/4'NH-F(Garden Thread)connections.Use NSF approved hose. DRAIN CONNECTION 1 1/4'NPT-M Do not connect other units to this drain. Drain line must be vented.Vented drain connection included. Do not connect drain to PVC pipe. © 0 1.06" OPERATING CLEARANCES 27mm 3"Left,3'Right and 4'Rear. 28.13" 715mm SERVICE CLEARANCES TOP 31.19" 12"on control side.Contact factory for variances to clearances. VIEW 792mm 49.32" CONTROLS 1253mm SureCook 60-minute electro mechanical timer with load compensating feature. 1217' \` Three function control switch for Timed Cooking and Continuous Steaming. APPROVALS 2.00" 18.13" UL and cUL listed,classified to NSF#4 and Energy Star 51 mm 461 mm 3/4"IPS 1.5" I� 549mm 'I DRAIN VENT 38mm CAPPED ACCESS PORT FOR DRAIN a 26. 5" 679mm 30. 5" 781 mm 1.5" 38mm ^ ^ O U O D 64rnm 4.00" 102mm 1.44" 18.74" 11.44" 1.69" 22.00" L4.32" 2.38" 37mm 467mm -� 37mm 43mm} 559mm 110mm 60mm FRONT VIEW RIGHT SIDE VIEW 1o8mm 57mm REAR VIEW l I ELECTRICAL(1) (Contact factory if installed above 3,500 feet) WATTS VOLTS PHASE WIRES CYCLE AMPS SUPPLY CONNECTION WATTS VOLTS PHASE WIRES CYCLE AMPS SUPPLY CONNECTION HERTZ WIRE SIZE(COPPER) HERTZ WIRE SIZE(COPPER) Standard Wattage Standard Wattage Three Phase-13.5 kW Standard Single Phase-13.5 kW Standard 13500 208 3 3 60 37.5 6 13500 208 1 2 60 64.9 4 11300 220 3 3 60 29.7 8 11300 220 1 2 60 51.4 6 13500 240 3 3 60 32.5 8 13500 240 1 2 60 56.3 4 11300 440 3 3 60 14.9 12 11300 440 1 2 60 25.8 8 13500 480 3 3 60 16.2 10 13500 480 1 2 60 28.1 8 Optional Low Wattage Optional Low Wattage Three Phase-9 kW option Single Phase-9 kW option 9400 208 3 3 60 26.1 8 " 9400 208 1 2 60 45.2 6 5440 220 3 3 60 20.9 10 5440 220 1 2 60 36.1 8 9400 240 3 3 60 22.6 10 9400 240 1 2 60 39.2 8 5440 440 3 3 60 10.4 14 5440 440 1 2 60 18.0 10 9400 480 3 3 60 11.4 14 9400 480 1 2 60 19.6 10 'For supply connection use only copper wire suitable for at least 75°C.(167T). (NOT TO SCALE) NOTES: SECT B PAGE Cleveland Range reserves right of design"rovement or modification,as warranted. Marry regional,state and local codes exist and it is the responsibility of the owner and installer to comply wadi the codes. O60g Cleveland Range equipment is buit to comply wilh applicat/e standards for manutacasers,Induded among those approval agencies are U.L/NSFs4 and CSA(AGA,CGA). Litho In U.SA Item# C.S.I.Section 11420 RESTAURANT RANGES vuLun ENDURANCE GAS RESTAURANT RANGE 6 OPEN BURNERS / 24" GRIDDLE 60" WIDE GAS RANGE ❑ 60-SS-6B-24G-N 2 Standard Ovens/Natural Gas ❑ 60-SS-6B-24G-P 2 Standard Ovens/Propane ❑ 60-SC-6B-24G-N 1 Standard Oven/1 Convection Oven Natural Gas ❑ 60-SC-6B-24G-P 1 Standard Oven/1 Convection Oven Propane STANDARD FEATURES M ■ Fully MIG welded frame ■ Stainless steel front,sides,backriser,lift-off high shelf i ■ 6"stainless steel adjustable legs CLTTT7 ■ Six open top burners,each burner is 30,000 BTU/hr. with lift-off burner heads ■ Shrouded flash tube pilot system(one pilot per two burners) ■ Heavy duty cast grates,easy lift-off 12"x 12 1/2"in front and 12"x 14 1/2"in the rear ■ 24" manual griddle,7/8"thick,4"wide front grease trough Model 60-SS-6B-24G-N ■ Extra deep pull out crumb tray with welded comers (shown with optional casters) ■ 25,000 BTU/hr. baker's depth oven cavity,full size cEs,ati sheet pans(18"x 26")fit front to back NSF ■ Oven thermostat adjusts from 250"F to 500°F CEETIi1E� ■ Heavy duty cool touch oven door handles Efilf�t' � ■ Two oven racks and four rack positions for each oven SPECIFICATIONS ■ 25,000 BTU/hr.convection oven in place of standard oven 60" wide gas restaurant range, Vulcan Model No. 60-SS-6B- 26 1/4"d x 20 1/4"w x 13 7/8"h(115v-1 phase blower 24G-N. Fully MIG welded aluminized steel frame for added motor 4 amp,6'cord and plug),includes three oven racks. durability. Stainless steel front, sides, backriser,highshelf and Full size sheet pans fit front-to-back in convection oven. 6"adjustable legs.Extra deep crumb tray with welded comers. ■ 1" rear gas connection and pressure regulator Six 30,000 BTU/hr.open top burners with lift-off burner heads. ■ One year limited parts and labor warranty Energy saving flashtube open burner ignition system(one pilotfor eve rytwo burners)shrouded for reliability.Heavydutycastgrates, ACCESSORIES (Packaged&Sold Separately) easy lift-off 12"x 12 1/2"in the front and 12"x 14 1/2"in the back to better accommodate stock pots or large pans.Grates have a ❑ Extra oven rack built in aeration bowl for greater efficiency.24"manual griddle, ❑ Extra rack guides(set of two) 7/8"thick,4"wide front grease trough.Burner knobs are cool to ❑ Casters(set of four) the touch, high temperature material.Two ovens:each oven is 25,000 BTU/hr.bakers depth ovens with porcelain oven bottom ❑ Flanged feet(set of four) and door panel, measures 26 1/4"d x 20 1/4"w x 14"h. Oven ❑ 10"stainless steel stub back thermostat adjusts from 250°F to 500°F with a low setting. Each oven is supplied with two racks, two rack guide sets, ❑ Reinforced high shelf for mounting salamander broiler and four rack positions. Oven doors are heavy duty with OPTIONS(Factory Installed) an integrated door hinge/spring mechanism requiring no adjustment. 1" rear gas connection and pressure regulator. ❑ Thermostatically controlled griddle(snap action) Total input 270,000 BTU/hr. Exterior Dimensions: 34 3/4"d x 60"w x 58"h on 6"adjustable legs vuLuna divisioup LLC P.O.Box 696 v Louisville,KY 40201 ■ Toll-free:1-800-814-2028 ■ Local:502-778-2791 a Quote&Order Fax: 1-800-444-0602 F-38269(1/10) RESTAURANT RANGES ENDURANCE GAS RESTAURANT RANGE vu�.c�n 6 OPEN BURNERS / 24" GRIDDLE 60" WIDE GAS RANGE INSTALLATION INSTRUCTIONS 1. A pressure regulator sized for this unit is included. 5. Clearances Rear Sides Natural gas 5.0"W.C., propane gas 10.0"W.C. Combustible 6" 10" 2. Gas line connecting to range must be 1"or larger. Standard Oven Non-combustible 0" 0" If flexible connectors are used,the inside diameter Convection Oven Non-combustible Min.4" 0" must be 1"or larger. 6. For proper combustion, install equipment on adjustable 3. An adequate ventilation system is required for commercial legs or casters provided with unit. cooking equipment. Information may be obtained by 7. For proper combustion.install equipment on adjustable writing to the National Fire Protection Association, legs or casters provided with unit. 1 Batterymarch Park.Quincy, MA02269.www.NFPA.org. When writing, refer to NFPA No.96. NOTE:In line with its policy to continually improve its 4. These units are manufactured for installation in product,Vulcan reserves the right to change materials accordance with ANSZ223.1A(latest edition), National and specifications without notice. Fuel Gas Code. Copies may be obtained from The American Gas Association.400 N Capitol St. NW, Specify type of gas when ordering. f Washington, DC 20001.www.AGA.org. Specify altitude when above 2,000 feet. 53 vz" APPLY TO CONVECTION MODELS 46 I/T M 17.3/S" GAB S" Joe.—. .. 14"OVEN CAVITY HEIGHT ® ® 37 O O 261/4"STD 201/4'OVEN I u 1)4,71 CAVITY DEPTH ADJUSTABLE CAVITY WIDTH TOP MODEL TOTAL INPUT SHIPPING WEIGHT CONFIGURATION NUMBER DESCRIPTION BTU/HR LBS/KG 60-SS-6B-24G-N 6 Burners/2 Standard Ovens/24"Griddle/Natural Gas 270.000 990/499 60-SS-6B-24G-P 6 Burners/2 Standard Ovens!24"Griddle/Propane 270,000 990/499 60-SC-6B-24G-N 6 Burners!1 Standard Oven/1 Convection Oven 270.000 1050/476 24"Griddle/Natural Gas 60-SC-6B-24G-P 6 Burners/1 Standard Oven 11 Convection Oven 270.000 1050/476 24"Griddle/Propane This appliance is manufactured for commercial use only and is not intended for home use. vuwAn a division of/TW Food Equipment Group LLC P.O.Box 696 • Louisville,KY 40201 r Toll-free: 1-800-814-2028 • Local:502-778-2791 ■ Quote&Order Fax:1-800-444-0602 NOTE.In line with its policy to continually improve its products,Vulcan reserves the right to change materials and specifications without notice. F-38269(1/10) �PrinwlOnRc<cdcJPapn 12/09/2009 12:16 3608487600 QUALITY FLOORS PAGE 03 Product Specifications ASSIJRANCETM 11 SHEET Construction Slip Retardant Sheet Flooring size 6'—(1.83m) Weariayer Thickness .080(2.03 mm) Overall Thickness .080(2.03 mm) Weight Per Square Yard 5.8 lbs/yds'(3.15 Kg/m') (•For packing weight it indudes interleaf of.04 Ibs per sq.yd.) Roll(Min.—Max.) 30—68 sq.yd, (25.1—56.9 sq.m.) Static Load Limit 760 psi ASTM Specification(F-1913) Exceeds HUD/FHA Requirements Exceeds Electrical Resistance, EN1815 s 2 kv Flooring Radiant Panel Test(ASTM-E-648 z .45 watts/crn'-,Passes(Class 1) I N.B.S. Smoke chamber Test(ASTM-E-662) <450-Passes Installation Adhesive Porous Sub-floor V-82/Full Spread Installation Adhesive Non-Porous Sub-flom V-95/Full Spread (Must use V 95 under OR tables,hospital beds and heavy rolling loads) Chemical Seam Sealer MLG-33 Heat Weld Seaming Mannington Commercial Solid Color Weld Rods Warranty Limited Five Year Commercial Warranty • Mannington Assurance 11 is not recommended in commercial areas that require static dissipation. • MannhMon Assurance 11 is not recommended in commercial areas where the surface temperature over radiant heated substrate exceeds 90'F. Mannington Assurance 11 can be installed in areas with topical moisture as long as V-95 adhesive Is used,seams are property sealed,and perimeter/edges are protected or ooved up the wail Meets the Americans with Disabilities Act Guidelines for static coefficient of friction as manufactured. • Meets CHPS 01350 Indoor Air Quality,Passed and Listed. • Dirt,wetness,finish selection and maintenance schedule may cause significant variation in actual performance. • Specifications are based on averages from normal manufacturing tolerances.Such variations do Trot affect product performance. • This product is intended solely for use as an indoor floor covering and Is not recommended or sold for any other Purpose. • Use entryway systems outside each entrance to prevent dirt,sand,grit and other substances from being tracked onto floor. floor adds score LRED VALDB Mannington Works MANNINGTON COMM ERCIAL.. ft(K)lA) Z7�1 m.+nnigl(Inq.Cnn+ 12/09/2009 12:16 3608487600 QUALITY FLOORS PAGE 03 Product Specifications ASSURANCE'"' 11 SHEET Constriction Slip Retardant Sheet Flooring Size 6-—(1.83m) Wearlayer Thickness .080(2.03 mm) Overall Thickness .080(2.03 mm) Weight Per Square Yard 5.8 Ibs/yd=•(3.15 Kg/m2) ('For packing weight it includes interleaf of.04 Ibs per sq-yd.) Roil(Min.—Max.) 30—68 sq.yd, (25.1—66.9 sq.m.) Static Load Limit 750 psi ASTM Specification(F-1913) Exceeds HUD/FHA Requirements Exceeds Electrical Resistance, EN1815 s 2 kv Flooring Radiant Panel Test(ASTM-E-648 Z.45 watts/crn:, Passes(Class 1) N.B.S. Smoke chamber Test(ASTM-E-662) <450-Passes installation Adhesive Porous Sub-ftoor V-82/Full Spread Installation Adhesive Non-Porous Sub-floor V-95/Full Spread (Must use V-95 under OR tables,hospital beds and heavy rolling loads) Chemical Seam Sealer MLG-33 Neat Weld Seaming Mannington Commercial Solid Color Weld Rods Warranty Untited Five Year Commercial Warranty 1 • Mannington Assurance II is not recommended in commercial areas that require static dissipation. • Manniroon Assurance II is not recommended in commercial areas where the surface temperature over radiant heated substrate exceeds 90'F. • Mannington Assurance it can be instaRW in areas with topical moisture as long as V-95 adhesive is used,seams are property sealed,and perimeter/edges are protected or ooved up the wall • Meets the Americans with Disabilities Act Guidelines for static coefficient of friction as manufac3ured. • Meets CHPS 01350 Indoor Air Ouality,Passed and Listed. • Dirt,wetness,finish selection and maintenance schedule may cause significant variation in actual perforrnanee. • Specifications are based on averages from normal manufacturing tolerances.Such variations do not ailed product performance. • This product is intended solely for use as an indoor floor covering and is not recommended or acid for any other purpose. • Use entryway systems outside each entrance to prevent dirt,sand,grit and other substances from being tracked onto floor. floor ieHo score VALUE MANNINGTON Mannington Works C O M M E R C I A L, BpOJA)7.•J,6Z m.mm�{(ron.u ' y s e ' CIRRUS Energy Waste Recycled Local Renewable Daylight I Acoustics Lay Emitting Square Lay-in & Tile M" Cordent Materials Materials &views or CHIPS ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ fine texture _ Items 574,533 Item 580 $$$`, Visual Selection Performance Selection Dots represent highest level of performance. It UL Classified Acoustics Fire Light Sag Anti- VOC Durable Recycle Edge Item Dimensions NRC CAC Rating Reflect Resist Microbial Formal- Program Profile No. ® dehyde IN CIRRUS Square Lay-in 15/161, 574 2'x 2'x 3/4" ❑ 0.70 35 Class A 0.86 HumiGuard* BioBlock. No Added S Yes Square Lay-in 071 574M 600 x 600 x 19mm • • • • • 574HRC' 2 x 2 x 3/4 533 2'x 4 x 3/4" 0 0.70 35 Class A 0.86 S No Added S 533M 600 x 1200 x 19mm • • • • 533HRC' 2'x 4'x 3/4" CIRRUS Tile Concealed 580 1'x 1'x 314" ❑ 0.65 40 Class A 0.86 No Added S Beveled K4C4 580M 300 x 300 x 19mm • • • ' • • r _. S=-Standard •The recycled content of this product is:54%pre-consumer;29%post-consumer Suspension Systems 15/16" Standard:Prelude" Concealed Standard:Prelude Concealed,Adhesive Physical Data Material No-Added Formaldehyde Backloadiny9 Recommendation Wet-formed mineral fiber No-added formaldehyde-free of formaldehyde-based Contact Tech Line for specific information resins.Outperform CHPS Section 01350 requirements. 3D-Year Performance Guarantee 8 Warranty Information Surface Finish (Independent test reports available upon request.) Factory-applied latex paint See warranty details at armstrong.com/warranty Anti Mold/Mildew a Bacteria Application Considerations Fire Performance BioBlock'Pluss contains an anti-microbial treatment and PP ASTM E84 and CAN/ULC 5102 surface burning provides guaranteed resistance against growth of Not recommended for rooms containing MRI equipment characteristics.Flame Spread Index 25 or less. mold/mildew and Gram-positive and Gram-negative Weight Square Feet/Carton Smoke Developed Index 50 or less.(UL labeled) odor/stain-causing bacteria for 30 years. 533,574-1.10 Ibs/SF;48 SF/ctn ASTM E1264 Classification Insulation Value 580-1.20 Ibs/SF;40 SF/ctn Type III,form 1,Pattern E I R Factor-1.9(BTU units) Fire Class A R Factor-0.33(Watts units) Sag Resistance HumiGuard'Plus-superior resistance to sagging in high humidity conditions up to,but not including, standing water and outdoor applications. Techl-ine-/1 877 ARMSTRONG 1 877 276 7876 anns11-109 om/ceilings(search:cirrus) A�Msumq• CS-3011-109 0 AWI Licensing Company,2009 Primed in the United States of America F ls, 4 0400111� Residential Mark E. Christ ;66 t'Sl ��6i�.S Commercial .\t"�..t'1...a4 Institutional Architect STA.fE C?F�!jnS�INIGTOiN' New Construction Renovdation (360) 855-1546 a. Remodel Programming 810 Bennett Street Destgn Sedro-Woolley, WA 98284 Documentation ' Administration markchrist.com j C E Richard Swanson 05/17/10 Washington State Department of Health Construction Review Services 310 Israel Road SE Olympia, WA 98501 RE: Chandler's Square CRS#60112372 Dear Richard, Enclosed please find sheet A23 documenting an expanded scope of work the Owner wishes to add to this project. Attached please fin the following supporting documents: 1. Chandler's Square Infection Control Procedures dated 5/15/10 • The Kitchen Air conditioning is to be installed during Kitchen off-hours • The Dining Room ceiling tile is to be installed during Dining Room off-hours 2. Kitchen Air Conditioning Product Literature 3. Convection Steamer and Range Product Literature 4. Sheet Vinyl Flooring Product Literature 5. Ceiling Tile Product Literature The flowing is a breakdown of the anticipated added cost to the project: Kitchen Air Conditioning: $ 6,500 Convection Steamer and Range: $ 13,108 Sheet Vinyl Flooring: $ 8,219 Ceiling Tile: $ 13,023 As always, should you have any questions concerning any of the above information please contact me. Thank you for your review of our project. W Mark Christ I of I c� AA Reettiirrementt Commjuunity �c, Qr VAIRE E 15 May 2010 To Whom it may concern: This memo covers the delivery of food to our 25 Assisted Living Residents during the times when the kitchen is anticipated to be unavailable due to the installation of a new kitchen floor. We anticipate completing the flooring above will take a total four days. The tentative plan is to begin the remodel Sunday night,after dinner,so affected meals would be B/L/D Monday through Thursday. All kitchen equipment would be stored in our Compass Room,leaving the Dining Room available for catered dining. Juice and Coffee Machines will not be affected, but limited to recyclable paper cups. Although we anticipate access to both the refrigerator and freezer during this time,there is a plan to install three(on-site)residential refrigerators in the Dining room to assist with breakfasts. Breakfast would consist of Muffins, Fruit,and Cold Cereal. All serving items will be disposable. Lunches and Dinners would be fully catered by local businesses,again all using fully disposable utensils and serving dishes.Fruit(apples and bananas)will be provided 24/7. I Sin r , Pete Kovach Director 1.300 `O'A.ven.ue Phone 360.29.3-1300 Anacortes, WA 98221 Fax 360-2.93-3923 ELESUBISHI CTIUC W.SLIM. HVAC Advanced Products Division spI t-ductless A/C and Heat Pumps Job Name: Location: Date: Purchaser: Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction f Unit Designation: Schedule No.: GENERAL FEATURES •Catechin and anti-allergy enzyme fitters for high air-purification capabilites •Updated sleek,compact indoor unit design / Indoor Unit MSY-D36NA •Remote-controlled wide airflow enables ideal horizontal air distribution •Self-check function—onboard diagnostics-Advanced microprocessor control •Auto restart following a power outage Wireless Remote Controller Outdoor Unit MUY-D36NA •Wireless remote controller •Limited warranty:five years on parts and defects and seven Indoor Unit years on compressors MCA.............. ......... .. ...................... 1A Fan Motor .................... .... ............ 0.76 F.L.A. OPTIONAL ACCESSORIES Airflow Outdoor Unit Cooling(Lo-Med-Hi)........ ... ...389-639-848 Dry CFM 350-576-763 Wet CFM •Drain Socket Assembly(MAC-811 DS) Sound Pressure Level Cooling(Lo-Med-Hi ...32 -42-49 dB(A) Indoor Unit )••••••----- �--- - •Three-pole Disconnect Switch(TAZ-MS303) •M-NET Control Adapter(MAC-3991F) DIMENSIONS UNIT INCHES/MM •MA Contact Terminal Interface(MAC-3971F) W 46-1/16/1,170 •Wired Remote Controller(PAR-21 MAA; Requires MAC-3971) D 11-5/8/295 •Centralized On/Off Remote Controller(MAC-821 SC; Up to H 14-3/8/365 eight units, requires one MAC-3971F per indoor unit) Weight .......... .. ..... ............. ..... .40 lbs. 118 kg •Condensate Pump(230V;S13100-230) External Finish....... . .. . . .. .. ... .Munsell No. 1.OY 9.2/0.2 E •Anti-allergy Enzyme Fitter(Two pieces per set;MAC-1415FT) Field Drainpipe Size O.D..... ............. .... 5/8"115.88 mm Remote Controller Wireless Cooling* (Optional Wired Remote Controller PAR-21MAA Rated Capacity.. . . ........... .. ..... .. .......34.600 Btu/h see Data Submittal Sheet) Minimum Capacity . .. ... .... ....... ............9,800 Btu/h SEER .. . .. ..... .. .. .............. ..........15-1 Btu/h/W Outdoor Unit Total Input...... .. ..... .. ..... ..................4.240 W DC Inverter-driven Rotary `Rating Conditions(Cooling)-Indoor 80°F(27°C)DB,67°F(19°C)WB;Outdoor 95°F Compressor ........ .... ... . y (35°C)DB.75°F(224°C)WB. MCA..... .. .............. .. ..... .. .. ........... ... 21 A Fan Motor.... ............ ....... .. ... .. ......0.93 F.L.A. Power Supply.... .. .. ... .. .......208/23OV,1-Phase,60 Hz Sound Pressure Level Breaker Size.... .. ......... .........................25 A Cooling 56 dB(A) Voltage DIMENSIONS INCHES/MM Indoor-Outdoor S1-S2 ....... ...............AC 208/230V W 33-11161840 Indoor-Outdoor S2-S3 .. ..... ..................DC 12-24V Indoor-Remote Controller.. .. .... ......... ... .....Wireless D 13/330 H 33-7/16/849 OPERATING RANGE Indoor Intake Air Temp. Outdoor Intake Air Temp. Weight .......... .. ......... ....... ..... ..126 lbs. / 57 kg 90°F(32°C)DB. External Finish.......... ..... . . . . . . .Munsell No.3Y 7.8/1.1 Maximum 73°F(23,C)WB '115°F(as°C)DB Refrigerant Type..-....-. Cooling 67°F(19°C)DB. Refrigerant Pipe Size O.D.Minimum 57°F(14°C)WS 1a°F(-1o°c)DB Gas Side... ............. ....... ... ...... 5/8"/15.88 mm Liquid Side........... .... ..... .... ..... ... 3/8"19.53 mm Max. Refrigerant Pipe Length.. .. ....... ..........100' / 30 in Max. Refrigerant Pipe Height Difference .. .... .......50' / 15 m Connection Method ................ .. ... ......... ...Flared "a� I N- ERR�R i DIMENSIONS: o ! MSY-D36NA 45-1/2 Unit: inch 2-11116 Ind"unft 411/16 46-1/16 2-3116 267/6 17-11116 -71 5-3I8 1 t-5/8 114 Wan tsole- V Air in t,swlao-m dale 2616 II Piping 2-15116 33111115 9-1/2 v a Wireless remote controller Required Space(Indoor Unit) -- 4nns °rain�° Air out 5-7/3 a c piping limitation Uyuid1. an19-11116 1-1/40.4 (Flared connection 08) :9116la _ l I Gas line #W16.718 at-15/160.11 (Joint connector e518) at-1/41.4 a ,Joint e5r8 ot-151160A For left;left,back;or left, (Flared connetion e5/8) 'at-1/41.4 f bottom piping(using spacer):5-118 or more Drat,hmel Insulation e1-118 Ctmleded pan 016 0.4 MUY-D36NA Unit:inch REQUIRED SPACE open as a rule 20 inch or more if the front and both sides are open 20-9/92 11.1.3 tslss il-2S/32 t-9/16 4 inch or more/ M5/10 Air is 2-9/32 � 8 inch or more it ----- - - there are obstacles to both sides C-A %� o1 d m% 74jn of Air nt 14/1.13/16 sin l9-ti/16 3 3-3/19 Open as a rule 20 inch or more If the back, 4 both sides and top are open I I 0 I � I •a I � � lloiCLl is.s :S/t AtMITSUBISHI ELECTRIC HVAC Advanced Products Division 3400 Lawrenceville Suwanee Rd Suwanee,GA 30024 ST� ® Tele:678-376-2900•Fax:800-889-9904 Toll Free:800-433-4822(#3) www.mehvac.com C SD-MSY-D36NA/MUY-D36NA-200909 0 MITSUBISHI ELECTRIC/HVAC 2009 Specifications are subject to change without notice. Project `—Cleveland Item FCSI Section HIGH EFFICIENCY BOILERLESS Approval STEAMCHEFTM CONVECTION STEAMERS Date anttsar. SteamChef IN 6 MODEL: ❑ 22CET6.1 Boilerless Convection Steamer, Technology Automatic Water Fill&Drain, 13.5 kW Boiler-Free Counter Type Design Cleveland Cleveland Standard Featufes ■ Cooking capacity for up to six 12"x 20"x 2.5"deep steam table pans(1/1 GIN,65 mm). ■ High-speed electric convection steamer with open style 1.5 gallon water reservoir located at the bottom of the cooking compartment „ for easy access and maintenance. ■ Fan forced convection steam with patented KfeanShield Im cooking compartment design.KleanShieldTM collects and removes condensate waste from the cooking compartment.This keeps the compartment clean,safe from impurities and easy to maintain. Eliminates foaming and avoids contamination of the reservoir water. ■ Automatic water level controls,fills when main power switch is turned ON,Low Water and High Water probes inside cooking compartment maintains water levels during cooking,eliminating the need to manually refill and monitor water level during cooking. , Additional Safety Overflow Standpipe.193`preheat and standby • temperature.High Temperature Safety Shut-off. ■ Steam and Fan Shut Off Control when compartment door is opened. ■ 13.5 kW electric heating elements are in aluminum blocks for fast Short FormSpecifications and ultra efficient heat transfer.Elements never need deliming because they are not immersed in water. Shall be a Cleveland SteamChef"6,model 22CET6.1,one compartment ■ Exclusive SureCook Compartment Controls improves cooking high-speed electric convection steamer._ volt,_phase. Standard speed and accuracy.New energy saving design reduces water and with SureCook Compartment Controls,60-minute electro-mechanical timer electric usage.On-demand power control for faster heat up and with load compensating feature.Capacity for six 2.5' 65 m)tuft size steam table pans. 13.5 kW electric healing elements in aluminum recovery.Energy saving Standby Feature when not in use.The blocks.Includes 1/2'bail valve style automatic drain.Automatic water level SureCook timer automatically adjusts the cooking time with the controls. Heavy-duty 14 gauge stainless steel cooking compartment door volume of product being cooked,eliminating guesswork on when and latch.KteanSh/eldl clean cavity protection.4'Adjustable Legs the product is finished.Includes a 60-Minute Electro-Mechanical Timer,LED Indicator Lights for SureCook Cycle, Power On and Reset.Timed and Manual Bypass Switch for constant steaming. ■ Exclusive SteamChefTm Automatic Drain Control.Generator Drains Options&ACCeWdes when main power is turned OFF via 1/2"ball valve with micro switch circuitry.Simple 1 1/4"NPT drain connection required with water O 34'(864mm)High Stainless Steel Economy Stand,for one 22CET6.1 saving cold water condenser and 3 minute rinse feature. (UniStand34) ■ left Hand Door Hinging:Compartment Doors hinged the left, Q 44'(1118mm)High Stainless Steel Stacking Stand(ES263044),for g g mounting two stacked 22CET6.1 controls on the right. O Right Hand Door Hinging,controls on right(DHR) ■ Exclusive,durable 14 gauge stainless steel compartment door and a ON/OFF Compartment control only, no timer(MC) latch withstands abuse and heavy wear.Two piece compartment O 5 Foot(1524mm)FDA Approved National Hose Thread style door with free floating inner door is self adjustable and prevents water connection kit(garden hose thread),2 required leaks.Reversible door gasket doubles the life of the gasket. (NHT60) ■ Heavy-duty 4"(102mm)Skid Resistant Adjustable Legs with O Single Point Water Connection(SPW) Flanged Feet. O Optional Voltages,480 Volt(VOS2),see back for ■ Meets agency codes:specifically UL and CUL listed,classified to alternative voltages. SECT B PAGE 3 NSF#4 and Energy Star. OW9 1333 East 179 St, Tel:1-216-481-4900 Web Site:www.clevelandRange.com Cleveland,Ohio,U.S.A.44110 Fax:1-216-481-3782 Email:Steam@ClevelandRange.com ! Canifowoc • Each compartment has capacity for:Six,12"x 20"x 2Y2"deep Cafeteria Pans. COLD WATER G 1:Feed water for reservoir,35 Psi Minimum,60 Psi Maximum. • Each compartment has capacity for:Twelve,12"x 20"x 1"deep Cafeteria Pans. • Each compartment has capacity for:Four,12"x 20"x 4-deep Cafeteria Pans. G2:Drain condenser water,35 Psi Minimum,60 Psi Maximum. Two 3/4'NH-F(Garden Thread)connections.Use NSF approved hose. DRAIN CONNECTION 1 1/4"NPT-M Do not connect other units to this drain. Drain line must be vented.Vented drain connection included. , Do not connect drain to PVC pipe. �© O 1 06" OPERATING CLEARANCES P7mm 3'Left,3'Right and 4'Rear. 28.13" 715mm SERVICE CLEARANCES TOP 31.19" 12"on control side.Contact factory for variances to clearances. VIEW 792mm 49.32" CONTROLS 1253mm SureCook 60-minute electro mechanical timer with load compensating feature. i 217' JO Three function control switch for Timed Cooking and Continuous Steaming. 4 z.00^ � APPROVALS 51 mm 18.13" UL and GUL listed,classified to NSF#4 and Energy Star 461 mm 21.63" 3/4"IPS 1.5" 549mm �I DRAIN VENT 38mm CAPPED ACCESS PORT FOR DRAIN Fad] 26. 5" 679mm 30. 5" 781 mm 1.5" 38mm C1 ® �r ® O © 2 5„ 4.00" 64mm 102mm 1.44" 18.74" _ 1.44" 1.69" 22.00" _I 4.32" 2.38" 37mm 467mm 37mm 43mm 559mm 110mm 60mm 4.25' 2.25" f FRONT VIEW RIGHT SIDE VIEW 108mm FFF 57mm REAR VIEW ELECTRICAL T (Contact factory if installed above 3,500 feet) WATTS VOLTS PHASE WIRES CYCLE AMPS SUPPLY CONNECTION WATTS VOLTS PHASE WIRES CYCLE AMPS SUPPLY CONNECTION HERTZ WIRE SIZE(COPPER) HERTZ WIRE SIZE(COPPER} Standard Wattage Standard Wattage Three Phase-13.5 kW Standard Single Phase-13.5 kW Standard 13500 208 3 3 60 37.5 6 13500 208 1 2 60 64.9 4 11300 220 3 3 60 29.7 8 11300 220 1 2 60 51.4 6 13500 240 3 3 60 32.5 8 13500 240 1 2 60 56.3 4 11300 440 3 3 60 14.9 12 11300 440 1 2 60 25.8 8 13500 480 3 3 60 16.2 10 13500 480 1 2 60 28.1 8 Optional Low Wattage Optional Low Wattage Three Phase-9 kW option Single Phase-9 kW option 9400 208 3 3 60 26.1 8 9400 208 1 2 60 45.2 6 5440 220 3 3 60 20.9 10 5440 220 1 2 60 36.1 8 9400 240 3 3 60 22.6 10 9400 240 1 2 60 39.2 8 5440 440 3 3 60 10.4 14 5440 440 1 2 60 18.0 10 9400 480 3 3 60 11.4 14 9400 480 1 2 60 19.6 10 I For supply connection use only copper wire suitable for at least 75T.(167T). I i NOTES: (NOT TO SCALE) Cleveland Range reserves right of design improvement or modification,as warranted. SECT.B PAGE 4 Marry regional,state and local codes exist and it is the responsibfity of the owner and installer to comply with the codes. 0609 Cleveland Range eopment is butt to comply wiQt aWicable standards for manutac¢xers Included among those approval agencies are U.UNSFx4 and GSA(AGA,GGA). Litho In U.SA Item# C.S.I.Section 11420 RESTAURANT RA NG ES ENDURANCE GAS RESTAURANT RANGE vARuLun 6 OPEN BURNERS / 24" GRIDDLE 60" WIDE GAS RANGE ❑ 60-SS-6B-24G-N 2 Standard Ovens/Natural Gas ❑ 60-SS-6B-24G-P 2 Standard Ovens/Propane ❑ 60-SC-6B-24G-N 1 Standard Oven/1 Convection Oven Natural Gas ❑ 60-SC-6B-24G-P 1 Standard Oven/1 Convection Oven Propane STANDARD FEATURES ■ Fully MIG welded frame ■ Stainless steel front,sides,backriser,lift-off high shelf Alk - - ■ 6"stainless steel adjustable legs ®i �1—TT7 ■ Six open top burners,each burner is 30,000 BTU/hr. with lift-off burner heads ■ Shrouded flash tube pilot system(one pilot per two burners) ■ Heavy duty cast grates,easy lift-off 12"x 12 1/2"in front and 12"x 14 1/2"in the rear ■ 24" manual griddle,7/8"thick,4"wide front grease trough Model 60-SS-6B-24G-N ■ Extra deep pull out crumb tray with welded corners (shown with optional casters) ■ 25,000 BTU/hr. baker's depth oven cavity,full size �EolA,y sheet pans(18"x 26")fit front to back ■ Oven thermostat adjusts from 250'F to 500°F NSF nFt�® CERIIEIED ® ■ Heavy duty cool touch oven door handles ■ Two oven racks and four rack positions for each oven SPECIFICATIONS ■ 25,000 BTU/hr.convection oven in place of standard oven 60" wide gas restaurant range, Vulcan Model No. 60-SS-6B- 26 1/4"d x 20 1/4"w x 13 7/8"h(115v-1 phase blower 24G-N. Fully MIG welded aluminized steel frame for added motor 4 amp,6'cord and plug),includes three oven racks. durability.Stainless steel front, sides, backriser, highshelf and Full size sheet pans fit front-to-back in convection oven. 6"adjustable legs.Extra deep crumb tray with welded corners. ■ 1" rear gas connection and pressure regulator Six 30,000 BTU/hr.open top burners with lift-off burner heads. ■ One year limited parts and labor warranty Energy saving f lashtube open burner ignition system(onepilotfor everytwo bum ers)shrouded forreliabiIity.Heavydutycastgrates, ACCESSORIES(Packaged&Sold Separately) easy lift-off 12"x 12 1/2"in the front and 12"x 14 1/2"in the back to better accommodate stock pots or large pans.Grates have a ❑ Extra oven rack built in aeration bowl for greater efficiency.24" manual griddle, ❑ Extra rack guides(set of two) 7/8"thick,4"wide front grease trough.Burner knobs are cool to ❑ Casters(set of four) the touch, high temperature material.Two ovens:each oven is 25,000 BTU/hr.bakers depth ovens with porcelain oven bottom ❑ Flanged feet(set of four) and door panel, measures 26 1/4"d x 20 1/4"w x 14"h. Oven ❑ 10" stainless steel stub back thermostat adjusts from 250°F to 500°F with a low setting. ❑ Reinforced high shelf for mounting salamander broiler Each oven is supplied with two racks, two rack guide sets, and four rack positions. Oven doors are heavy duty with OPTIONS(Factory Installed) an integrated door hinge/spring mechanism requiring no adjustment. 1" rear gas connection and pressure regulator. ❑ Thermostatically controlled griddle(snap action) Total input 270,000 BTU/hr. Exterior Dimensions- 34 3/4"d x 60"w x 58"h on 6"adjustable legs wLun a division ollTW Food Equipment Group LLC P.O.Box 696 a Louisville,KY 40201 IF Toll-free: 1-800-814-2028 ■ Local:502-778-2791 • Quote&Order Fax: 1-800-444-0602 F-38269(1/10) RESTAURANT RANGES vu n ENDURANCE GAS RESTAURANT RANGE 6 OPEN BURNERS / 24" GRIDDLE 60" WIDE GAS RANGE INSTALLATION INSTRUCTIONS 1. A pressure regulator sized for this unit is included. 5. Clearances Rear Sides Natural gas 5.0"W.C., propane gas 10.0"W.C. Combustible 6" 10" 2. Gas line connecting to range must be 1"or larger. Standard Oven Non-combustible 0" 0" If flexible connectors are used,the inside diameter Convection Oven Non-combustible Min.4" 0" must be 1"or larger. 6. For proper combustion. install equipment on adjustable 3. An adequate ventilation system is required for commercial legs or casters provided with unit. cooking equipment. Information may be obtained by 7. For proper combustion. install equipment on adjustable writing to the National Fire Protection Association. legs or casters provided with unit. 1 Batterymarch Park. Quincy, MA02269,www.NFPA.org. When writing, refer to NFPA No.96. NOTE:In line with its policy to continually improve its 4. These units are manufactured for installation in product,Vulcan reserves the right to change materials accordance with ANSZ223.1A(latest edition), National and specifications without notice. Fuel Gas Code. Copies may be obtained from The American Gas Association. 400 N Capitol St. NW Specify type of gas when ordering. Washington. DC 20001.www.AGA.org. Specify altitude when above 2,000 feet. APPLY TO CONVECTION MODELS a6 1/7 35, 9 1/2" 6U 7' 17.3/8" i as see �� ��>�.. ® 59 la"OVEN CAVITY HEIGHT ® 37' 2a 1/2' O O 261STD 6"77/1" 201/4"'OVEN TO1/4' G4NT'DEPTH ADJUSTABLE CAVITY WIDTH TOP MODEL TOTAL INPUT SHIPPING WEIGHT I CONFIGURATION NUMBER DESCRIPTION BTU/HR LBS/KG 60-SS-6B-24G-N 6 Burners/2 Standard Ovens/24"Griddle/Natural Gas 270.000 990/499 60-SS-6B-24G-P 6 Burners/2 Standard Ovens l 24"Griddle/Propane 270.000 990/499 60-SC-6B-24G-N 6 Burners!1 Standard Oven/1 Convection Oven 24"Griddle/Natural Gas 270.000 1050/476 60-SC-6B-24G-P 6 Burners/1 Standard Oven/1 Convection Oven 24"Griddle/Propane 270.000 1050/476 This appliance is manufactured for commercial use only and is not intended for home use. vuwv scan a division of ITIN Food Equipment Group LLC P.O. Box 696 ■ Louisville,KY 40201 ■ Toll-free:1-800-814-2028 ■ Local:502-778-2791 ■ Quote&Order Fax: 1-800-444-0602 F-38269(1/10) NOTE:In line with its policy to continually improve its products,Vulcan reserves the right to change materials and specifications without notice. Prrticl(ln Rr<vcic.l A.,w-- 12/09/2009 12:16 3608487600 QUALITY FLOORS PAGE 03 Product Specifications ASSURANCETM 11 SHEET i Construction Slip Retardant Sheet Flooring Size 6-—(1.83m) Wearfayer Thickness .080(2.03 mm) Overall Thickness .080(2,03 mm) Weight Per Square Yard 5.8 The/yw•(3.16 Kg/m=) ('For packing weight it includes interleaf of.04 lbs per sq.yd.) Roil(Min.—Max.) 30—68 sq.yd. (25.1 —56.9 sq.m.) Static Load Limit 750 psi ASTM Specification(F-1913) Exceeds HUD/FHA Requirements Exceeds Electrical Resistance, EN1815 s 2 kv Flooring Radiant Panel Test(ASTM-E-648 2 .45 Watts/cm=, Passes(Class 1) N.B.S. Smoke chamber Test(ASTM-E-662) <450-Passes Installation Adhesive Porous Sub4loor V-82/Full Spread Installation Adhesive Non-Porous Sub-floor V-95/Full Spread (Must use V-95 under OR tables, hospital beds and heavy rolling loads) Chemical Seam Sealer MLG-33 Heat Weld Seaming Mannington Commercial Solid Color Weld Rods Warranty Umited Five Year Commercial Warranty c • Mannington Assurance If is not recommended in commercial areas that require static dissipation. • Mannir4on Assurance II is not recommended in commercial areas where the surface temperature over radiant heated substrate exceeds 90'F. • Mannington Assurance 11 can be installed in areas with topical moisture as long as V-95 adhesive is used,seams are property seated,and perimeter/edges are protected or ooved up the wall • Meets the Americans with Disabilities Act Guidelines for static coefficient of friction as manufactured. • Meets CHPS 01350 Indoor Air Quality,Passed and Listed. • Dirt,wetness,finish selection and maintenance schedule may cause significant variation in actual performance. • Specifications are based on averages from normal manufacturing tolerances.Such variations do not affect product performance. • This product is intended solely for use as an indoor floor covering and is not recommended or sold for any outer purpose. • Use entryway systems outside each entrance to prevent dirt,sand,grit and other substances from being tracked onto floor. floor Rea. score n.Heo VALUE Mannington Works MANNINGTON goo 7A 17.'l.(w minninwon.Con, COMM E R C I A I„ 12/09/2009 12:16 3608487600 QUALITY FLOORS PAGE 03 Product Specifications ASSURANCE'" 11 SHEET t Construction Slip Retardant Sheet Flooring Size 6'—(1-83m) Wearlayer Thickness .080(2.03 mm) Overall Thidmess .080(2.03 mm) Weight Per Square Yard 5.8 lbs/yds'(3.15 Kg/m� (•For packing weight it includes interleaf of.041be per sq.yd.) Roll(Min.—Max.) 30—68 sq.yd, (25.1—56-9 sq.M.) Static Load Limit 750 psi ASTM Specification(F-1913) Exceeds HUD/FHA Requirements Exceeds Electrical Resistance, EN1815 s 2 kv Flooring Radiant Panel Test(ASTM-E-648 2.45 watts/cm:, Passes(Class 1) N.B.S. Smoke chamber Test(ASTM-E-682) <450-Passes Installation Adhesive Porous SubAloor V-82/Full Spread Installation Adhesive Non-Porous SubAoor V-95/Full Spread (Must use V-95 under OR tables, hospital beds and heavy rolling loads) Chemical Seam Sealer MLG-33 Heat Weld Seaming Mannington Commercial Solid Color Weld Rods Warranty Limited Five Year Commercial Warranty • Mannington Assurance II is not recommended in commercial areas that require static dissipation. • Mannington Assurance II is not recommended in commercial areas where the surface temperature over radiant heated substrate exceeds 90'F. • Mannington Assurance 11 can be installed in areas with topical moisture as long as V-95 adhesive Is used,seams are property seated,and perimeter/edges are protected or coved up the wall. Meets the Americans with Disabilities Act Guidelines for static coefficient of friction as manufactured. • Meets CHPS 01350 Indoor Air Ouatity,Passed and Listed. • Dirt,wetness,finish selection and maintenance schedule may muse significant variation in actual performance- • Specifications are based on averages from normal manufacturing tolerances.Such variations do not affed product performance. • This product is intended solely for use as an indoor floor covering and Is not recommended or sold for any other purpose. • Use entryway systems outside each entrance to prevent dirt,sand,grit and other substances from being tracked onto floor. fl or' Lgeo sc8re VALUE Mannington Works MANNINGTON 80O7A1 7' i7 m—n,ngton.Com C 0 M M E R C I A L, CIRRUS t$ � t 4 4 : • � Energy Waste Recycled Local Renewable Daylight Acoustics Lox EmRbttg Square Lay-in & Tile Mgtd ,tern Matenals Materals aVewS or clips fine texture tea°° °monde"` Items 574,533 Rem 580 Y.X Visual Selection Performance Selection Dots represent highest level ofperformance. V UL Classified Acoustics Fire Light Sag Anti- VOC Durable Recycle Edge Rem Dimensions NRC CAC Rating Reflect Resist Microbial Formal- Program Profile No. ® ® � ® dehyde CIRRUS Square Lay-in 15116" 574 2'x 2'x 3/4" ❑ 0.70 35 Class A 0.86 HumlGuard+ BioBlock. No Added S Yes Square Lay-in 574M 600 x 600 x 19mm • • • • • 574HRC' 2'x 2'x 3/4 533 2'x 4'x 3/4" 0.70 35 Class A 0.86 S No Added S 533M 600 x 1200 x 19mm • • • • 4 533HRC• 2'x 4 x 3/4" CIRRUS Tile Concealed 580 1'x 1'x 3/4" 11 0.65 40 Class A 0.86 No Added S {Beveled�K4C4 560M 300 x 300 x 19mm • • • • • • {—�—� S=_St andartl f •The ecycled content of this product is:54%pre-consumer;29%post-consumer Suspension Systems 15/16" Standard:Prelude" Consealed Standard:Prelude Concealed,Adhesive Physical Data Material NO-Added Formaldehyde Backloading Recommendation Wet-formed mineral fiber No-added formaldehyde-free of formaldehyde-based Contact TechLine for specific information Surface Finish resins.Outperform CHPS Section 01350 requirements. (Independent test reports available upon request.) 30-Year Performance Guarantee 8 Warranty Information Factory-applied latex paint See warranty details at armstrong.com/warranty Anti Mold/Mildew con 3 Bacteria Application Considerations Are Performance provides Plus contains an anti-microbial treatment and Not recommended for rooms containing MRI equipment ASTM E84 and CAN/ULC 5102 surface burning provides guaranteed resistance against growth of g characteristics.Flame Spread Index 25 or less. mold/mildew and Gram-positive and Gram-negative Weight;Square feet/Carton Smoke Developed Index 50 or less.JUL labeled) odor/stain-causing bacteria for 30 years. 533,574-1.10 Ibs/SF;48 SF/ctn ASTM E1264 Classification insulation Value 580-1.20 Ibs/SF;40 SF/ctn Type III,Form 1,Pattern E I R Factor-1.9(BTU units) Fire Class A R Factor-0.33(Watts units) Sag Resistance HumiGuard"Plus-superior resistance to sagging in high humidity conditions up to,but not including, standing water and outdoor applications. Techl-ine-11 877 ARMSTRONG 1 8/c 276 7876 /�_ �..}r - arms11-109 om/ceilings(search:cirrus) m�Y CS-3011-109 V AWI Licensing Company,2009 Primed in the United States of America