HomeMy WebLinkAboutCOR-2009-Planning Review Comments - Anacortes Planning & Community Development Dept.
Permit Center
P.O.Box 547,Anacortes,WA 98221-0547 PH(360)293-1901
Ryan Larsen,Director • Don Measamer,Building Official FAX(360)293-1938
I
September 17, 2009
Anacortes Senior Housing
Lanny Wixon
1300 "O"Avenue
Anacortes, WA 98221
RE: 1300 "O"Avenue
Chandler Square
The following are comments and questions regarding the plan review done on the above
mentioned project. Please revise drawings as necessary.
1. Class I standpipe system is required per Section 905.3.1 Exception 1.
2. Lock box at each entry point.
3. Sprinkler/Standpipe FDC's &PIV per AFD.
4. 2AIOB Extinguisher for every 3,000 square feet maximum travel distance 75
feet.
5. Provide listings for all fire resistive assemblies include noise ratings, etc.
I
6. Specifically all required special inspections to the plans such as concrete and
shear walls.
7. Are phones provided at the stair rescue areas? Provide details for area of
refuge per IBC Section 1007.6— 1007.7 signs, etc.
8. Provide analysis to show how parking corresponds with Anacortes Municipal
Code Section 17.46.020.
9. Provide unit per acre calculation.
i
10. Provide building height calculations based on average grades prior to
excavation consistent with survey elevations (to building elevations)use
constant datum for future reference.
i
11. Indicate all deferred submittals.
12. Public Works review to follow.
Sincerely,
CITY OF ANACORTES
Don Measamer
Assistant Director of Planning/Building Official
Mark,
Please provide an addendum which can be attached to the plans that shows your calculations for
area, number of units allowed and proposed, lot area and allowed coverage with proposed
coverage, building height proposed with contours and calculations to support the height.
Thank you,
Don Measamer
City of Anacortes
Assistant Director, Planning &
Community Development,
Building Official
Don@cityofanacortes.org
Phone 360.293.1901
Fax 360.293.1938
From: mark christ [mailto:mark@markchrist.com]
Sent: Wednesday, September 23, 2009 5:06 PM
To: lanney60lncw@yahoo.com
Cc: Measamer, Don
Subject: Fw: Chandlers Square additon
Hi Lanney,
I had not had an opportunity to respond when I got your call earlier today:
RE: Area Calculation
I thought we had gone through a Conditional Use Permit and all of the Zoning issues were
addressed at that time.
We are still adding 25 apartments as indicated. However, we are now deleting 1 of the 66 existing
apartments. This gives us a total of 90 apartments. This is less than the 108 apartments that Don
said we were permitted to have. (correspondence follows)
RE: Parking Spaces
As I recall it was agree to that; assuming we didn't lose any of the existing parking spaces, we
were permitted to calculate additional parking requirements (which to be located on the new site)
based on the Addition. We are adding 25 apartments X 0.8 spaces per apartment= 20 parking
spaces. We are adding 26 standard parking spaces plus(3)ADA parking spaces for a total of 29
parking spaces.
Note: This was agreed to because the original Chandler's Square was so under designed for
parking that even while adding 9 extra spaces we are still 8 spaces short for the overall site. This
could not have been a viable project otherwise.
RE: Building Height
On April 10th 1 mentioned that we were 9"over the 35' height limit with a 6/12 pitch and I asked if
this would this be acceptable. It was not. Therefore the roof pitch was reduced to 5.4/12 in order
to reduce the height. Please see A& B on sheet A11. Likewise the Clocktower was reduced in
height by 4". Please See A& B on sheet Al which indicates both the roof heights in relation to
the Existing Average Grade. I will forward my email with attachments from April 6th in which I
provided the height calculations. There has been no change in the floor to floor heights. The roof
pitch was reduced to 5.4/12 and the Clocktower attic was reduced by 4" in order to comply.
Sincerely,
Mark Christ
i
-----Original Message-----
From: mark christ
To: Lanney Wixson
Sent: Tuesday, May 13, 2008 2:30 PM
Subject: Re: Chandlers Square additon
Hi Lanney,
It sounds like Don is giving us the maximum number of units permitted by the zoning code, based
on the size of your property.
If the zoning code permits a maximum of 108 units, and we are currently at 66 units; then we i
have a balance of 42 units. In this case, the maximum number of units may still be dictated by the
associated parking and the physical constraints of the site.
At your request, I will be glad to discuss providing you with a proposal for architectural services.
The schematic design phase of architectural services typically includes a review of both the
zoning code and the building code for compliance issues.
Sincerely,
Mark Christ
-----Original Message-----
From: Lanney Wixson
To: Mark Christ; Mark Wiesner ; Paul Dendy
Sent: Monday, May 12, 2008 9:07 AM
Subject: Fw: Chandlers Square additon
l
Here is a message from the building dept giving us units for CS expansion
----- Forwarded Message ----
From: "Measamer, Don" <donkcityofanacortes.org>
To: Lanney Wixson<lanney601ncw a yahoo.com>
Cc: "Deaton, Michelle" <michelleAcityofanacortes.org>
Sent: Monday, May 12, 2008 7:49:22 AM
Subject: RE: Chandlers Square additon
Hello Lanny,
Based on R4 USE Zone and the area from the center line of 12 th street, O Ave, N Ave to the
Center line of the Southerly Alley 168,562 square feet= 3.86 acres 28 units per gross acre = 108
units.
Total 108 Units.
l 1
Thank you,
Don Measamer
City of Anacortes
Assistant Director, Planning &
Community Development
Senior Plans Examiner
Don(a)-cityofanacortes.org
Phone 360.293.1901
Fax 360.293.1938
From: Lanney Wixson [mailto:lanney60lncw@yahoo.com]
Sent: Friday, May 09, 2008 10:19 AM
To: Don Measamer
Subject: Chandlers Square additon
Don,
Recognizing the city comes up with a little different number than the architect does,
could you provide me with a calculation of the number of units we can add to Chandlers
Square on lots 1-8 Block 56, Map of the City of Anacortes .
Currently we own all of lots
lots 1-10 Block 55 300' x 100'
Vacated 13th St 300' x 80'
Lots 9-18 Block 56 300'x 100'
Lots 1 - 8 Block 56 300'x 100'
Assume we can vacate the block 56 alley 300' x 16'
300 x 396
N Ave, O Ave , and 12th St are all 80' streets.
We currently have 66 units in Chandlers Square
Thanks
Lanney
Be a better friend, newshound, and know-it-all with Yahoo! Mobile. Try it now.
Be a better friend, newshound, and know-it-all with Yahoo! Mobile. Try it now.
0
elevation (ft) length of perimeter(ft) elevation x length
17.0 76.0 1292.0
18.0 42.0 756.0
19.0 32.0 608.0
20.0 27.0 540.0
21.0 28.0 588.0
22.0 26.0 572.0
23.0 27.0 621.0
24.0 30.0 720.0
25.0 43.0 1075.0
26.0 69.0 1794.0
27.0 31.0 837.0
28.0 115.0 3220.0
29.0 31.0 899.0
subtotals 577.0 13522.0
average existing grade 23.4
l 1
35'-9"
4'-7"
�y 31'-2"
Ile
i �
d
r
< r 0
CD
a
F-r (/] CD N 7 N p
00 �•
r d y o x
H C-
ii H
dz
t� 0 0
12" 12" Ll
- 8'-0" 8'-0" 8'-0" 12'�0" 6"
4,-7„
45'-9"
50'-4„
4' 12' 21' 23' 4'
i
J i
N
j J
i
m
N m
m x
n 4 q (N
N Q �
N Z
4� p -_.--- O Z
Ti
5, 5'... N O D
ZD �
m z -
N �
z - -
r
- O
D --N O
z m - m
r
UT._—
N Z N D
10'
-- n 0) \ D
_ 4
r
rn 00
Cn
N 34
0)
.....N_ 2' m ,
N
_ N
U N
N N
O
21. 23' 6'
O
O —�
i
TOPOGRAPHIC STUDY TO DETERMINE AVERAGE EXISTNG GRADE
CHANDLER'S SQUARE INDEPENDENT LIVING
MARK CHRIST,ARCHITECT
DATE:04/06/09 SCALE: 1"=20'-0"